Loading...
1661 ATLANTIC BEACH DR - DENSITY TEST V IV I V E R S A L UES Project No: 0910.1400187.0000 g p Workorder No: 176269-1 ENGINEERING SCIENCES Report Date: 09/14/2016 Consultants In:Geotechnical Engineering•Environmental Sciences Geophysical Services•Materials Testing •Threshold Inspection Building Code Administration,Compliance Inspection&Plan Review 5561 Florida Mining Blvd So.,Jacksonville,FL 32257 -P:904-296-0757 -F:904-296-0748 In-Place Density Test Report Client: Toll Brothers, Inc UES Technician: Kelly McKinley 160 Cape May Avenue Date Tested: 09/14/2016 Ponte Vedra, FL 32081 Project: Atlantic Beach Country Club Atlantic Beach Country Club 1661 Atlantic Beach Dr, Atlantic Beach, Duval County, FL 32233 Type of Test: Area Tested: Lot 11 Field: ASTM D-6938 Nuclear Gauge Method Material: Fill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Top of Fill The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 1 12' N by 12' E from SW corner 0- 1 ft 103.3 14.3 103.1 10.7 100 Pass 2 12' N by 12'W from SE corner 0- 1 ft 103.3 14.3 105.3 9.7 102 Pass 3 12'S by 12'W from NE corner 0- 1 ft 103.3 14.3 102.6 12.0 99 Pass 4 12'S by 12' E from NW corner 0- 1 ft 103.3 14.3 103.0 10.2 100 Pass To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1 UNIVERSAL UES Project No: 0910.1400187.0000 Workorder No: 176269-1 ENGINEERING SCIENCES Report Date: 9/14/2016 Ig21 Consultants In:Geotechnical Engineering•Environmental Sciences Geophysical Services•Construction Materials Testing•Threshold Inspection Building Inspection•Plan Review•Building Code Administration 5561 Florida Mining Blvd So.,Jacksonville, 32257 • P:904-296-0757 • F: 904-296-0748 In-Place Density Test Report Client: UES Technician: Kelly McKinley 160 Cape May Avenue Date Tested: 09/14/2016 Ponte Vedra, FL 32081 Project: Atlantic Beach Country Club Area Tested: Lot 11 Type of Test: Material: Fill Field: ASTM D-6938 Nuclear Gauge Metho Reference Datum: 0 = Top of Fill Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. Maximum Optimum Field Dry Field Soil Fill TestDepth Pass Density Moisture Density Moisture Compaction No. Location of Test Range (pcf) (°/) (pcf) (% (%) (inch) or Fail 1 12' N by 12' E from SW corner 0 - 1 ft 103.3 14.3 103.1 10.7 100 N/A Pas: 2 12' N by 12'W from SE corner 0 - 1 ft 103.3 14.3 105.3 9.7 102 N/A Pas: 3 12' S by 12'W from NE corner 0 - 1 ft 103.3 14.3 102.6 12.0 99 N/A Pas: 4 12' S by 12' E from NW corner 0- 1 ft 103.3 14.3 103.0 10.2 100 N/A Pas: Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization FORM BOARD ELEVATION CERTIFICATE Date 9- 3/- /c Permit Number: /'_ c/c* -ley Address: /1// �1-/e?' 4c /e / / / - All yAll American Surveyors Work Order # /s/36/ Required Slab Elevation on City Approved Site Plan: /a• 70 Actual Elevation of Form Board or Grade Stake: /a . OD Survey Company: ALL AMERICAN SURVEYORS OF FLORIDA INC. 3751 San Jose Place, Suite 15 Jacksonville FL 32257 Work Phone: 904-279-0088 Signature of Surveyor: (PartyChief) � • •