Loading...
702 CAVALLA RD - LOW SLOPE ROOF r \.,`Jr:= 'assCITY OF ATLANTIC BEACH f 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 r i JJ,lJ� ROOF PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-ROOF-1981 Job Type: ROOF PERMIT Description: RE-ROOF PORCH , LOW SLOPE Estimated Value: $1,166.00 Issue Date: 9/12/2016 Expiration Date: 3/11/2017 PROPERTY ADDRESS: Address: 702 CAVALLA RD RE Number: 171365-0040 PROPERTY OWNER: Name: LOPANIK, SAMUEL M Address: 702 CAVALLA RD GENERAL CONTRACTOR INFORMATION: Name: NELIGAN CONSTRUCTION (ROOFING) , CCC1325888 Address: PO BOX 49249 QA BRIAN D NELIGAN Phone: 904-853-5523 FEES: PLAN CHECK FEES $27.92 BUILDING PERMIT FEE $55.83 STATE DCA SURCHARGE $2.00 STATE DBPR SURCHARGE $2.00 Total Payments: $87.75 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITU OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ,.sLAPP City of Atlantic Beach APPLICATION NUMBER r. 4 ' 4k: Building Department (To be assigned by the Building Department.) a 1s� 800 icSeminolec Road 1/ —Roo P. - 198 9 Q r Atlantic Beach, Florida 32233-5445 l0 !(J T.) Phone(904)247-5826 • Fax(904)247-5845 2 on I "4110v E-mail: building-dept@coab.us Date routed: 3t II City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 7oz 1T FALL A D nt review required Yes/ No c uilding V Applicant: N) C-1,-LE A� 0 N.. -. Hing &Zoning Tree Administrator Project: R -R00 F PO 2C'ei Public Works Public Utilities L© v , S Lc Public Safety Fire Services Review fee $ Dept Signature • Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ['Denied. (Circle one.) Comments: \\ G) PLANNING &ZONING Reviewed by: PI / Date: 9)-NE? TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 BUILDING PERMIT APPLICATION ! _R00 /98 I CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904)247-5845 Job Address: 702 Cavalla Rd. Permit Number 125;°- it —0 Legal Description 31-1 38-2S-29E Royal Palms Unit 2A E 19.4ft of W 27.25ft Lot 3 Blk 16 Valuation of Work $1166.00 Proposed Work heated/cooled non-heated/cooled Class of Work(circle one) Residential, Multi-family, Re-roof low slope back porch roof only, FL 10497 R5 Renail decking to code, install Mule-hide two ply root system. Use of existing/proposed structures)(circle one): Vi If an existing strucure,is a fire sprinkler system installed? (Circle one): Yes No N/A Z., SC-0PC Property Owner Information: Name:Sammuel Lopanik Address: 702 Cavalla Rd. City Atlantic Beach State FL Zip 32233 Phone 514-8761 E-Mail or Fax# (Optional) Contractor Information: Company Name: Neligan Construction and Roofing, LLC_Qualifying Agent: Brian Neligan Address:910 11th Ave. South City Jacksonville Beach_State FL Zip 32250 Office Phone 853-5523 Job Site/Contact Number_568-8700 Fax#904-572-1211 State Certification/Registration# CCC 1325888 Architect Name & Phone# Engineer's Name & Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for aperiod of six(6)months at any time after work is commenced. 1 understand that separate permits must be secured for Electrical Work, Plumbing,Signs, Wells, Pools, Furnaces, Boilers, Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined thisplication and know sa to true and correct. All provisions of laws and ordinances governing this type of work will be complied with w ether specified herein or not. e • if ting o a permit does not presume to give authority to violate or cancel the provisions of any other federal,stat , r local law regulating c cit n •, e perfo anis of construction. Signature of Owner /eJt/► . / I • SHERRI L STEPP 11/ r° -1.�•s Notary Public-State of Florida : _•: ,'• .•; Commission 0 FF 991762 Print Name �� p l i "j�F,�,4'$ My Comm.Expires May 31.2020 Sworn to and subscribed bef re mem __ _ Bonded through N ionai=Assn.. this 3 ( Day of AV 7{J ,2014' N. . IT I, c AP() 8 ( I I I \v, r--„,:-.--::,.„„ SHERRI L STEPP Signature of Contractor /6.6P =r'•'^11.��s Notary Public-State of Florida ,___ . Commission N FF 994762 1.`a,���A. My Comm.Expires May 31.2020 Print Name Brian Neligan %°F P..'' Bonded through National Notary Assn. Sworn to and subscribed before me this Day of , 20 /n(j( FILE Al-r-49L COPY Q., TRINITY I ERE) APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WINO UPUFT RESISTANCE Table Deck Application Type Description Pale 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 3 18.1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4 18-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5 1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6 10 Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 7 1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 8 1E-2 Wood New.Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 9 1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9 2A Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 10 28 Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 11 3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 12-14 3A-2 Concrete New Ci Reroof(Tear-Off) A•1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 18 38 Concrete New or Reroof(Tsar-Off) F Non-Insulated,Bonded Roof Cover 18 4A LWIC New or Reroof(Tsar-Off) A-1 Bonded Insulation,Bonded Roof Cover 16-17 48 LWIC New or Rer00t(Tsar Off) _ A 2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 17 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 18-19 SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 20 SB CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet.Bonded Insulation,Bonded Roof Cover 20 SC CWF New or Reroof(Tear-Off) E Non-Insulated,Meeh.Attached Base Sheet,Bonded Roof Cover 20 GA Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 21 68 Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 22 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 22-23 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AM. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: i•Wood: Minimum 0.75-inch penetration. -Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. i Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral-wool roof board that meets the QA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHI.Load resistance of the roof deck shall be documented through proper codified and/or F8C Approval documentation. Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report M10000.03.08-R5 for FL10497-R5 Certificate of Authorization a9503 Revision S:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 1 of 23 TRINITY ERD 5. Unless otherwise noted,insulation adhesive application rates are as follows.Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. Hot asphalt Full coverage at 25-30 lbs/square. .Dow Insta-Stik Roofing Adhesive(D-15): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. .Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. OMG OlyBond 500(08500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot).Note:OlyBond Green may be used where OlyBond 500 is referenced. X.OlyBond Classic(013 Classic): Full coverage at 1 gal/square. 3M CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. Note:When multiple layers(s)of insulation and/or coverboard ore installed in ribbon-applied adhesive,board joints shall be staggered. 'Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MOP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MOP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board fisted below may be used as a drop-in for the equivalent thicker material listed in the table: Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) i OMG OlyBond 500(08500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) • OMG OlyBond 500(08500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) .OMG OlyBond 500(08500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) OMG OlyBond 500(08500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II,Poly ISO 2) i 3M CR-20: MDP -117.5 psf (Min.1.0-inch thick) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPOS 1-29. Assemblies marked with an asterisk`carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 10. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system.Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI F%-1 11. For existing substrates in a bonded recover installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM 1907,FM LPOS 1-52,ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 3130 psi. In all cases,the minimum topcoat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,LIC.d/b/a Trinity(ERD Evaluation Report M10000.03.0816 for FL10497-R5 Certificate of Authorization#9503 Revision S:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 2 of 23 TRINITY ERD 14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. TABLE 1:MULE-HIDE Roor Covtas i Reference SBS-SA (SBS,Self-Adhering) layer Material Application Bax Ply One or more plies SA Bax Sheet,SA Base Sheet(FR) Cap SA-SBS Cap Sheet,SA-SBS Cap Sheet(FR) Self-Adhering Note: Self-adhering membranes shall not be Installed over APP-TA membranes. APP-TA Base Ply or Ply One or more plies APP Torch Base,APP Torch S Tach-Applied (APP,Torch-Applied) Cap APP Torch S,APP Torch G,APP Torch G FR,APP Torch KoolCap G,APP Torch KoolCap G FR APP-SA Cap SA-APP Cap Sheet,SA-APP Cap Sheet(FR),SA-APP KoolCap G,SA-APP KoolCap G(FR) Self-Adhering (APP,Self-Adhering) Note: 54-adhering membranes shall not be Installed over APP-TA membranes. 15. Any FBC Approved coating listed for use with SBS or APP modified bitumen roofing may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. 16. The following represent priming requirements for gypsum-based coverboards: Dens Deck and Dens Deck Prime shall be field-primed with Mule-Hide 121 prior to self-adhering or torch-applied membrane application. SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application. 17. 'MDP`=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. TABLE 1A:WOOD DECKS—NEW CONSTRUCTION oR REROOF(TEM-OPe) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck Base insulation Layer Top Insulation Layer Roof Cover(See Table 1) MDP No. (See Note 1) Type Attach Type Attach Base Ply Ply Cap (pif) SKr-Amain SAURYSNm SAME MLuzATtotitea OPnoimaTop IIlRulATnwwo.THE SAME TIN: j Min.15/32- Min.1.5-inch ACFoam Il,ACFoam III,ENRGY-3,H- D-I5,M-OSFA, (Optional)additional D-IS,M-OSFA. SBSSA,APP-SA, W-1EG-SAA (Optional)SBS-SA,APP-TA -52.5 inch plywood Shield,H-Shield CO.CG,Mutti-Max FA3 08500 or CR-20 layers(s)of base insulation 08500 or CR-20 APP-TA Exterior Research and Design,LLC.d/b/a Trinity HERD Evaluation Report M10000.03.08-R5 for FL10497-R5 Certificate of Authorization 09503 Revision 5:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 3 of 23 • • TRINITY ERD TABLE 1B-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) • SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(See Table 1) System Deck MDP Base • No. (See Note 1) Type Fasten Attach Type Attach Type Attach Ply Cap (IND TouoMMtIto BASE Ry: Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)Min.1.5• Min.19/32- CertainTeed Glasbase, inch diameter tin lap and 8-inch o.c. inch ACFoam If, Min.0.25-inch Dens Poly ISO 2,ENRGY- Deck,Dens Deck Pnme, Hot (Optional) • W-2 inch Firestone MB Base,IM caps with 11 ga. in three(3),equally Hot asphalt APP-TA APP-TA -60.0 plywood Perma-Ply 28,Tamko annular ring spaced,staggered 3,M-Shield,Poly Fiber RSECURoof Gypsum- asphalt APP-TA • Glass Base,GAFGLAS 075 shank nails center rows ISO 2,H-Shield CO. Fiber Roof Board Multi-Mae FA3 9-inch o.c.in 4-inch (Optional)Min.1.5- inch ACFoam II, Min.0.25-inch Dens Min.IS/32- lap and 9-inch o.c. Simplex MARX Poly ISO 2,ENRGY Deck Prime,SECUROCK Hot (Optional) W-3 inch Polyglass G2 Base Cap in four(4),equally 3,II-Shield,Poly Not asphalt Gypsum-Fiber Roof asphalt APP-TA APP TA APP-TA -82.5 plywood spaced,staggered I50 2,H-Shield CG, Board center rows Multi-Max FA3 (Optional)Min.15- 32 ga.,1-5/8- 6-inch o.r,in 4-inch inch ACFoam II, Min.0.25-inch Dens Min.15/32- inch diameter tin lap and 6-inch o.c. Poly ISO 2,ENRGY- Deck Prime,SECUROCK Hot (Optional) W-4 inch Polyglass G2 Base caps with 12 ga. in five(5)equally Hot asphalt APP-TA APP-TA -90.0 plywood annular ring spaced,staggered 3,H-Shield,Poly Gypsum-Fiber Roof asphalt APP-TA shank nails center COWS 150 2,H-Shield CO. Board Multi-Max FA3 SN-AmeNftE BASE Pun: Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)Min.1.5- inch ACFoam II, Min.0.25-inch Dens Min.19/32- CertainTeed Glasbase, inch diameter tin lap and 8-inch o.c. (Optional) 585-SA, Poly 150 2,ENRGY- Deck,Dens Deck Prime, Hot W-5 inch Firestone MB Base,1M caps with 11 ga. in three(3),equally Hot asphalt SBS-SA 5655A,APP- APP-SA, LO.o 3,H-Shield,Poly Fiber R CK Gypsum- asphalt Glass Base,GAFGLAS 075 shank nails center rows ISO 2,H-Shield CO. Fiber Roof Board Multi-Max FA3 32 ga.,1-5/8- 6-inch o.c.in 4-inch Min.2-inch D-15,08500, ACFoam II,Poly ISO CR-20.M- D-15, Min.19/32- inch diameter tin lap and 6-inch o.c. (Optional) 585-SA, i W-6 inch Nail Base caps with 12 ga. in tour(4),equally 2,ACFoam III,H- °SFA,atop (Optional)Additional OB500, SBSSA APP- App-SA, -60.0• Shield,Poly ISO 1, fastener layers of base insulation CR-20, plywood annular ring spaced,staggered TA TA APP-TA shank nails center rows H-Shield CG,Multi- rows,7-inch M-OSFA Max FA3,ENRGY-3 o.c. ( Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report M10000.03.08-Rb for FL10497-R5 Certificate of Authorization 09503 Revision 5:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 4 of 23 TRINITY ERD TABLE 1B-2:WOOD DECKS-NEW CONSTRUCTION,RE ROOF(TUR-Orn)OR RECOVER SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(See Table 1) System Deck MOP Base No. (See Note 1) Type Fasten Attach Type Attach Type AttachPlY Ply Cap (PA ToecH-AVH[o East PLY: 12-inch o.c.in 4-inch (Optional)Min.1.5-inch lap and 12-inch o.c. ACFoam II,Poly ISO 2, Min.0.25inch Dens Min.19/32- OMG Flat Bottom Plates Hot Deck,Dens Deck Prime, Hot (Optional) W.7 inch plywood Nail Base (square)with Roofgrip 1412 m two(21,equally ENRGY-3,H-Shield,Poly asphalt SECUROCK Gypsum- asphalt APP TA APP-TA APP-TA -60.0 spaced,staggered ISO 2,H-Shield CG,Multi- Fiber Roof Board center rows Max FA3 Dekfast Hex Plates with Dekfast 414,OMG 3" Round Metal Plate with 9-inch o.c.in winch (Optional)Min.1.5-inch Min.0.25-inch Dens Min.15/32- Polyglass OMG HD,OMG Flat lap and 9-inch o.c.in ACFoam II,Poly ISO 2, Hot Deck,Dens Deck Prime, Hot (Optional) W 8 inch plywood G2 Base Bottom Plate(Accutrac) four(4).equally ENRGY-3,H-Shield,Poly asphalt SECUROCK Gypsum- asphaltAPP-TA APP TA APP-TA -82.5 Multi- with Roofgrip 1414 or spaced,staggered ISO 1,H-Shield CG,Muhi- Fiber Roof Board Trufast 3'Metal Insulation center rows Max FA3 Plate with Trufast HD. SEv-AOHEeING BASE Ply: 12-inch ac.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens lap and 12-inch o.c. ACFoam II,Poly ISO 2, (Optional) SBS-SA, Min.19/32- OMG Flat Bottom Plates Hot Deck,Dens Deck Prime, Hot W-9 Nail Base in two,equally ENRGY-3,H-Shield,Poly SBS-SA SRS-SA.APP- APP-S0. -60.0 inch plywood ywood (square)with Roofgrip 412 spaced,staggered 150 2,H-Shield CG,Multi asphalt SECUROCK Gypsum- asphalt TA APP-TA center rows Max FA3 fiber Roof Board Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report M10000.03.08-R5 for FL10497-RS Certificate of Authorization 49503 Revision 5:12/14/2015 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 23 TRINITY ERD TABLE IC:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck(See Top Insulation Layer Roof Cover(See Table 1) Base Insulation Layer MDP(psi) No. Note 1) Type Fasten Attach Base Ply Ply Cap TORCH-APPLIED BASF PLY: r Dekfast Hex Plates with Dekfast#14, (Optional)One or more Min.0.25-inch Dens Deck OMG 3"Round Metal Plate with OMG Min.15/32- 1 per 2 W-10 layers,any combination, Prime or SECUROCK HD,OMG Flat Bottom Plate(Accutrac) APP-TA (Optional)APP-TA APP-TA -30.0 inchPlywood loose laid Gypsum-Fiber Roof Board with Roofgnp X14 or Trufast 3"Metal (Y Insulation Plate with Trufast HD. SIIF-ADHERING BASE PLY: Dekfast Hex Plates with Dekfast X14, (Optional)One or more Min.0.25 inch Dens Deck OMG 3"Round Metal Plate with OMG Min.15/32- 1 per 2 SBS-SA,APP-SA, W-11 inch plywood layers,any combination, Prime or SECUROCK HD,OMG Flat Bottom Plate(ACcutraC) ttz SBS-SA i (Optional)SBS-SA,APP-TA APP-TA -30.0 loose laid Gypsum-Fiber Roof Board with Roolgrip 014 or Trufast 3"Metal Insulation Plate with Trufast HD. I Min 19/32- (Optional)One or more Min.1.5-inch ENRGY 3,H- Dekfast Galvaiume Steel Hex with Dekfast 1 per SBS-SA,APP-SA, W-12 mch plywood layers,any combination, Shield,Poly ISO 1,Polytherm X12 DP or Mule-Hide 3"Insulation Plate 1 33 to 585-SA (Optional)SBS-SA,APP-TA APP-TA -82.5 loose laid with Mule-Hide Drill Point Fastener Exterior Research and Design,LIC.d/b/a Tnnityl ERD Evaluation Report M10000.03.08-R5 for F110497-RS Certificate of Authorization#9503 Revision 5:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 6 of 23 TRINITY ERD TABLE 10:WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D.PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER Insulation layers) . Base Sheet Roof Cover(See Table 1) System Deck(SeeMOP(psf) No. Note 1) Type Attach j Base 1 Fasten Attach Base Ply 1 cap TORN-ARRA°Bas[PLY: Nail Base,Polyglass G2 Base, OMG Flat Bottom Plates(square) One or more 12-inch o.c.in 4-inch lap and 12- Min.19/32- Prelim. CertaMTeed Glasbase,Firestone MB with Roofgrip#14,Dekfast Hex with W-13 layers,any inch o.c.in two(2),equally (Optional)APP-TA APP-TA -S2.5 inch plywood combination Attached Base,1M Perma-Ply 28,Tamko Glass Dekfast 414 or Trufast 3'Metal spaced,staggered center rows Base or GAFGLAS 475 Insulation Plate with Trufast HD One or more 12-inch o.c.in 4-inch lap and 12- Min.19/32- Prelim. OMG Flat Bottom Plates(square) W-14 inch plywood layers,any Attached Nail Base with Roofgrip#12 inch o.c.in two(2),equally (Optional)APP-TA APP-TA -60.0 combination spaced,staggered center rows Dekfast Hex Plates with Dekfast 414,OMG 3'Round Metal Plate One or more 10-inch o.c.in 4-inch lap and 10- Min.15/32- Prelim. with OMG HD,OMG Flat Bottom W-15 inch plywood layers,any Attached Potyglass G2 Base,Nail Base Plate(Accutrac)with Roofgrip#14 inch o.c.in three(3),equally (Optional)APP-TA APP-TA -75.0 combinationspaced,staggered center rows or Trufast 3"Metal Insulation Plate with Trufast HD. Dekfast Hex Plates with Dekfast -- 414,OMG 3'Round Metal Plate One or more 9-inch o.c.in 4-inch lap and 9- Min.15/32- Prelim. with OMG HD,OMG Flat Bottom W-16 inch plywood layers,any Attached Polyglass G2 Base,Nail Base Plate(Accutrac)with Roofgrip 414 inch o.c.in four(4),equally (Optional)APP-TA APP-TA -90.0 combinationspaced,staggered center rows or Trufast 3'Metal Insulation Plate with Trufast HO. I SW-AMMO BAST Ptn: One or more Dekfast Hex with Dekfast 414 or 12-inch o.c.in 4-inch lap and 12- SBS-SA, Min.19/32- Prelim. W-17 inch plywood layers,any Attached Nail Bax Mule-Hide 3"Insulation Plate with inch o.c.In two(2),equally SBS-SA APP-SA, -52.S' • combination Mule-Hide HDP Fastener spaced,staggered center rows APP-TA One or more 12-Inch o.c.in 4-inch lap and 12- SBS-SA, Min.19/32- Prelim. OMG Flat Bottom Plates(square) 585-SA APP-SA, -60.0' W-18 layers,any Nail Base kids o.c In two(2).equally Inch plywoodcombination Attached with Roolgrip 412 spaced,staggered center rows APPTA Exterior Research and Design,LLC.d/b/a Trinity I FRO Evaluation Report M10000.03.08-R5 for F110497-RS Certificate of Authorization 49503 Revision 5:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 7 of 23 TRINITY ERD TABLE SE-1:WOOD DECKS-NEW CONSTRUCTION OR REROOF(TUR-Orf) SYSTEM TYPE E:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(NARs),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover(See Table 1) i MOP No. Note 1) Base Fasten ` Attach Base Ply Cap TOWleAPPUto BASE PLY: W-19 Min.15/32- Nail Bax Simplex MAXX Cap 9-inch o.c.at 2-inch lap and 18-inch o.c.in two(2), (Optional)APP-TA APP-TA -45.0' Inch plywood equally spaced,staggered center rows Min.15/32- 9-inch o.c.at 2-inch lap and 12-inch o.c.in two(2), W20 inch plywood Nail Base Simplex MAS Cap equally spaced,staggered center rows (Optional)APP-TA APP-TA -52.5 W-21 Min.15/32- APP Torch Base,Nail Base Original Simplex Cap Nails fl-inch metal head diameter, 6-inch o.c.at 3-inch lap and 6-inch o.c.in four(4), (Optional)APP-TA APP-TA .52.5 inch plywood 11 gouge x min.1.25-inch long annular grooved shank) equally spaced,staggered center rows Nail Bax,Polyglass G2 Base, W 22 Min.19/32- CertainTeed Glasbase,Firestone 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.in 4-inch lap and 8-inch o.c.in three(3), (Optional)APP-TA APP-TA -60.0 inch plywood MB Base,JM Perma-Ply 28,Tamko ring shank nails equally center rows spaced,staggered Glass Base or GAFGLAS 875 W 23 Min.15/32- Polyglass G2 Base,Nail Base 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.in 4-inch lap and 8-inch o.c.kh four(4), (Optional)APP-TA APP-TA -67.5 inch plywood ring shank nails equally spaced,staggered center rows Min.15/32- 10-inch o.c.in 4-inch lap and 10-inch o.c.in three W24 Inch plywood Polyglass G2 Base,Nail Base Simplex MAXX Cap (3),equally spaced,staggered center rows (Optional)APP-TA APP-TA -75.0 W-25 Min.ls/32• Polygiass G2 Base,Nail Base Simplex MAXX Cap 9-inch o.c.in 4-inch lap and 9-inch o.c.in four(4), inch plywood equally spaced,staggered center rows (Optional)APP-TA APP•TA -90.0 W-26 Min.15/32- Nail Base Simplex MARX Cap 6-inch o.c.at 2-inch lap and 6-inch o.c.in two(2), (Optional)APP-TA APP-TA -90.0 inch equally spaced,staggered center rows Min.15/32- 6-inch o.c.at 2-inch lap and 6-inch o.c.in three(3), (Optional)APP-TA AMU -105.0 W27 inch plywood Elastobax Simplex MAXX Cap equally spaced,staggered center rows W•28 Min.19/32- Elastobase or Elastobase Poly 32 ga.,1.5/8-inch diameter tin caps with 11 ga.annular 6-inch o.c.in 4-inch lap and 6-inch o.c.in four(4), (Optional)APP-TA ADP-TA -112.5 inch plywood ring shank nails equally spaced.staggered center rows SAFAaeeewa BASE PLY: Min.15/32• Original Simplex Cap Nails(1-inch metal head diameter, 6-inch o.c.at 3-inch lap and 6-inch o.c.in four, (Optional)58S-SA585-x• - -52.5 W-29 inch plywood Nail Base 11 gouge x min.1.25-inch long annular grooved shank) equally spaced,staggered center rows SA,APP-TA W Min.19/32- Na8 Bax 32 ga.,1-S/8-inch diameter tin caps with 11 ga.annular 8-inch o.c.in 4-inch lap and 8-inch o.c.in three, SBS-SA,APP- inch plywood ring shank nails equally spaced,staggered center rows (Optional)SSS-SA SA,APP-TA -60.0 W-31 Min.19/32- Nail Bax 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular 4-inch o.c.in 4-inch lap and 4-Inch o.c.in four, (Optional)585-SA 585-SA,APP- -g7.5 Inch plywood ring shank nails. equally spaced,staggered center rows SA,APP-TA Min.19/32• 32 ga.,1-5/8-inch diameter tin caps with 11 ga.annular SBS-SA APP- W32 Nail Base ring shank nails.Note:Tin caps are to be primed with 6-inch o.[.in 4-inch lap and 6-inch o.c.in four, (Optional)SBS-SA -112.5 Mach plywoodMule-Hide 121 or ASTM 041 primer. equally spaced,staggered center rows SA,APP-TA Exterior Research and Design,LLC.d/b/a Trinity)1E RD Evaluation Report M10000.03.08-R5 for f L10497-R5 Certificate of Authorization 89503 Revision 5:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 8 of 23 TRINITY ERD TABLE 1E-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAK-OFF)OR RECOVER SYSTEM TYPE E:NON-1NSLILATEO,MECHANICALLY ATTACHED BASE SHEET(scenes&PLATEs),BONDED ROOF COVER System Deck(See Base Sheet Roof Cover(See Table I) MDP(psi) No. Note 1) Base I Fasten I Attach Base Ply I Cap Tome-Ammo BASE PLT•. Nail Base,Polyglass G2 Base, OMG Flat Bottom Plates(square)with Min.19/32- CertainTeed Glasbase,Firestone 12-inch o.c.in 4-inch lap and 12-inch o.c.in two W-33 inch plywood MB Base,JM Derma-Ply 28,Tamko #14,Dekfast Hex with Dekfast 1114 or Trufast P 3' (Optional)APP-TA APP-TA .52.5 Metal Insulation Plate with Trufast ND (2),equally spaced,staggered center rows Glass Base or GAFGLAS#75 W-34 Mia 19/32- Nail Base OMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in two (Optional)APP-TA APP-TA -60.0 inch plywood #12 (2),equally spaced,staggered center rows Dekfast Hex Plates with Dekfast#14,OMG 3' W-35 Min.15/32- polyglazs G2 Base.Nail Base Round Metal Plate with OMG HD,OMG Flat 10-inch o.c.in 4-inch lap and 10-inch o.c.in three (Optional)APP-TA APP-TA -75.0 inch plywood Bottom Plate(Accutrac)with Roofgrip 1114 or (3),equally spaced,staggered center rows Trufast 3"Metal Insulation Plate with Trufast HD. Dektast Hex Plates with Dekfast 1114,OMG 3" W-36 Min.15/32- Polyglass G2 Base,Nail Base 3- Metal Plate with OMG HD,OMG Flat 9-inch o.c.in 4-inch lap and 9-inch o.c.infour(4), (Optional)APP-TA APP-TA -90.0 Inch plywood Bottom Plate(Accutrac(with Roofgrlp#14 or equally spaced,staggered center rows Trufast 3"Metal Insulation Plate with Trufast HD. Min 15/32- OMG#12 Standard Roofgrip or OMG N14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in three W-37 inch plywood Metal Torch Base or Nail Base Duty(min.1.5/8-inch long)with OMG 3'Round 13),equally spaced,staggered center rows (Optional)APP-TA APP-TA -90.0 Metal Plates or OMG Flat Bottom Metal Plates Min.15/32- OMG#12 Standard Roofgrip or OMG1114 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in five(5), W-313APPplywood APP Torch Base or Nail Base Duty(min.1-5/8-inch long)with OMG 3"Round equally spaced,staggered center rows (Optional)APP-TA APP-TA -120.0 Metal Plates or OMG Flat Bottom Metal Plates SIU-ACRtewc BASE PLY: Min.19/32- Nail Base Dekfast Hex with Dekfast 1114 or Mule-Hide 3" 1 12-inch o.c.in 4-inch lap and 12-inch o.c.in two, 585-SA S135-5A.APP-APP-SA -52.5' W-39 inch plywood Insulation Plate with Mule-Hide HDP Fastener equally spaced,staggered center rows APP-TA W-40 Min.19/32- Nail BaseOMG Flat Bottom Plates(square)with Roofgrip 12-inch o.c.in 4-inch lap and 12-inch o.c.in two, SBS SA SBSSA,APP-SA ,60 0, inch plywood #12 equally spaced,staggered center rows APP-TA TABLE IF:WOOD DECKS—NEW CONSTRUCTIONORREROOF(TEM-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(See Roof Cover(Sea Table 1) MDP No. Note 1) Primer loth Treatment Base Ply Ply Cap Min.15/32- SBS-SA (Optional)SBS-SA,APP- 585-SA,APP-SA,APP. _90.0W-41 inch plywood (Optional)Mule-Hide 121 None TA TA W-42 (Optional)15/32- (Optional)Mule-Hide 121 Plywood joints are covered with minimum 4-inch wide strips of SA Base Sheet, SBS SA (Optional)SBS-SA,APP- SBS-SA.APP-SA,APP- -135.0 inch plywood rolled Into place to create continuous bond. TA TA Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report M10000.03.08-R5 for FL10497-R5 Certificate of Authorization#9503 Revision S:12/14/2015 Prepared by:Robert Nieminen,PE-59166 Appendix 1,Page 9 of 23