2001 MiPaula Ct HVAC permit CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 16-MECH-2274
Job Type: MECHANICAL HVAC ONLY
Description: replace one (1) 4.0-ton AHU
Estimated Value: $5,869.00
Issue Date: 10/11/2016
Expiration Date: 4/9/2017
PROPERTY ADDRESS:
Address: 2001 MIPAULA CT
RE Number: 169506-1034
PROPERTY OWNER:
Name: FISHER, GLEN G AND IRENE M,
Address: 2001 MIPAULA CT
GENERAL CONTRACTOR INFORMATION:
Name: OCEAN STATE HEAT &AIR,INC.
,CACO49310
Address: 1476 ATLANTIC BLVD QA JAMES GLENN JONES
Phone: -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $20.00
AC and Refrigeration $32.00
State Mech DBPR Surcharge $2.00
State Mach DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $111.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES
MECHANICAL PERMIT APPLICATION f 000
CITY OF ATLANTIC BEACH "
goo Seminole Rd Atlantic Beach,FL 32233
- - Ph!I(90/4)247-�5�8226 Fax(904)247-5845 I b1e
-A46;
"OB ADDRESS: Z&11 �'.Q'�'^-'CS> 111 RAJ PERMrr9
o G
PROJECT VALUE$ 5AARI# 5W60—_609 REQUIRED
_Air Handling Equipment Only _*Air Handling Unit& Condenser _Condenser O
MW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity ,Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratinl;REQUIRED
Duct Systems: Total CFM
tEPLACEMENT AIR CONDITIONING & HEATINGEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit / .�
Heat: Unit Quantity I Ecru's Per Unit 000 Seer Rati SQUIRED
Duct Systems: Total CFM _
--M PREVENTION (Regains 3 sets of pleas)
FirFre Sprinkler System Q (Reyes 3 sets of plans)
Un StandValuepipe 3 sets of lana
Fire Hose
Ca metsue n guar (Requires plans)
Fite Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods QQuantity Hires 3 sets of plans)
Firet Suppression Systems •(Requires 3 sets of plans)
IRE PLACES MISCELLANEOUS:
pre" ted FiRfi�'Qty _ 'Automobile Lifts
Gas Piping Outlets. - .Boilers BTUs
Elevators/Escalators
I,IL OTHER GAS-PIPING Heat Fs.:? "ge
Quantity of."etsPUMPS
#Vented Walll Fttmaces " Refrigerator Condenser BTU's
#Water Heaters - Sol"Collection.Systems
Tanks(gallons)
. Welts
)THER:
or work orebaMmed row srs tttoMAs.Ihemby oertjfy Nazl
.. .i,wpr�ewm avnodidkiwfwwuNdedneos wbetm euacdew A M ap�ovtle9iPww¢nodrkgamdt%erdl adg
oe!Ng this work will be cmplied with whpNv
xTWPmdog,K=Ww wvkd,,pw ormyoNewknlbmmwia*mcomGncimortheperrnceoron
roperty Owmers NameSh/y/ - Phone Number a -a
4echanical Company ��l-.e- (�A4 d'/7/✓ of Phone a�F4 " 'Vf
/4 7te H7�/a 6I� city stateZip
;o.Address: C rr�
—
eeense Holder(Print): C" / State Certffication/Reglstranon##
lorarized S ARY PUBLIC - - —..
STATE OF FLORIDABefo this I of 20
rm nW EE$79174 �7
EMkes 312/2817 Sigosnue of N lie
M This combination qualifies for a Federal Energy
CERTIFIED- Efficiency Tax Credit when placed in service
between Feb 17, 2009 and Dec 31, 2016.
L- www.ahridirectory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 5766009 Date: 10/10/2016
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 4TWX804BAl
Indoor Unit Model Number: 'AM7AOC48H41
Manufacturer: TRANE
TradelBrand name: TRANE
Series name: XL181
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 47000
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 17.00
Heating Capacity(Btuh)@ 47 F: 46000
Region IV HSPF Rating (Heating): 9.00
Heating Capacity(Btuh)@ 17 F: 30000
'Ratings bllowea by an aslerwk V)i v late a voluntary rerele of previously pablislml dare,unless accompanied Win a WAS,who talk' les an imdunury remle.
DISCLAIMER
AHRI does not endorse Me Droducl(s)listed on Mis CerlMcate and makes no representations,warreoles or guarantees as to,and assumes,m re-aponobilhy,for,
Me products)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of Me use or performance of the products),or the
naohomed aNemtlon of data listed on this Cera e.CeoN ratings are valid only for models and configurations listed in the
directory at www.ahridiwctory.org.
TERMS AND CONDITIONS
Thk Certificate and its contents are pmpdetary products W AHRI.Thin CedMwte shall only be used for individual,personal and
confidential reference purposes The contents of this CeRMcete may not,in whole or in part,M reproduced;copied;disseminated; A. ■■ -'
entered into a computer Combase;or othemise Nlllzed,In any brm or manner or by any mean,amen forthe users Indolduel,
peOnaland confidentul Naomi AIRCONDITIONING,INSTITUTE R
CERTIFICATE VERIFICATION 8 REFRIGERATION xsniuilS
The Information far the model cited on this ttRlNcame Can be worried!atwww.ahridirectory.org,click..'Verlfy Certificate'link .
and enterthe AHRI Certified Reference Number and the Cate an which the certMcata vans ksued.
which Is listed above,and Me CeriMcatm No.,which N listed o bottom right. 131206085366865669
®2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: