121 Donner Rd revised energy sheets CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach,Florida 32233 Telephone(904)247-5800 FAX(904)247-5845 REVISION REQUEST SHEET OR CORRECTIONS TO REVIEW COMMENT Date: 10 -a V-/6 Received by: Resubmitted: Permit Number: 16-5FAT'- 11f9y Original Plans Examiner: Project Name: Project Address: 12l Contractor: ELK (.Wo" /fiar.ear/Ii,.,..hon fir. Contact Name: 1q..vsIZIJw Contact Phone: 9011_ 60-4$IS Contacte-mail: 3kco,u +cLe i,46 k dOkrno,iwn Revision/Plan Check/Permit Fee(s)Due: S 50.00 D 2 O 2 R IV Descriroposed Revision to ExistingPermit: ef f IL'cS D Additional Increase in Building Value: S C Additional S.F. _ Site Plan Revised: NO Public W/U Approval: By signing below.I(Mint wmr) 'Wlttr B /�` affirm that the above revision is inclusive of posed changes. 1019�I6 Sign of tractor/Age t(cana rnn Z sips ainrr inwwion) Date Om«Use Only oar: f0 APpnnnW Rqj : N«lardby: _ Plan Reviewll turn nts: PnrauA � r< s S�bm }�m� R,-SCa, nvv � r�e sefi nolr �v rr,/ldvac k n -M fe%ck- n -S'ab CCf�f /kia ff"f- errt review requinad Yes No Building -- g&Zo Tree Administrator Plans Examiner Public Works { Public Utilities t Public Safety Date rmrmana u..r Fire Services FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section 1?405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) OFFICE COPY REVISION BP# /b- sFl?T- /Y9z DATE t D 1_W l /G SIGNED_ EnergyGauge®-USRCZB v5.1 Page 1 of 1 10I13I2016 5:53:2]PM _ OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C ONS ocRe Meth IO Florida Department of Business and Profess ional Regulation - Residential Builder Nanre: Elie Guam Fomes and Renovations Project Name: ECHunit Permft Olfia'. Street Donner Rd Permit Number City,State- 2rp: Jacksonville FL, Junod chm 261 t 0 0 111 Deaver: mber latson County-, Duval(Florida Climate Zone 2) Deaver: Design Locdaon: FL,Jacksonville 12760 sgt) Insulation Area N.(From Plans) 9. Wall Types( R=19.0 1140.00@` 1. New construction or einsling a.From_Wood.Bdenront FW9.0 136-00 t' family Multilomily b.Frame-Wood,Adjacent R- fP 2. Single tangy or multiple1 d WA c NIA R 3. Number of units,t multiple/amity Insulation Area 3 4. Number of Bedrooms 10.Ceiling Types (7730 soil) R-38.0 773.0011° No a.Under Atac(Verrted) R- t' 5. Is this a worst case? b.WA R= IF 6. Conditions, ,or area above grade Qt) 1518 c.WA R t` 0 11.Duda n 1 6 180 Conditioned a:or area below grade Me) Area a-Sup:At ic,Rat AtiF AU:Batrraor 7. Wiindows(143.0 soft.) Dill n 128008 a. UFador. kBtutt Efficiency SHGC: SF�.30 15.00 ft' 12.Cooling systems 360 SEER 15-00 IF U-Factor Da•U=0.30 a.Central Unit S11GC: sHGC=0.35 ft: kBaJhr Efficiency c. U-Fackr WA 13.Fleeting systems 36.0 HSPF'e 50 SHGC: SHGC: R' a Electric Heat Pump tl. U-Facror WA SHGC: 500 Area Weighted Aveoaye owmang Depth O 3 t' 14.Hot water systems Cap 40 gallons Area Weighted Average SHGG'. a.Eloctric EF'0 950 Insulation Area 8. Foor Types (1518.0 sqR) R-00 74800 R' In. Conservation features a.Slab-Gn�Grade Edge Insulation R-0 0 707.00 ft? one CF.Pslat b.Floor Over Other Space 63-00 t 15.Credits R= `.other(see details) PASS Total Proposed Modified Loads: 34.82 Glass/Floor Area: 0.094 Total Baseline Loads38.09 O4g11E 5TgTE Review of the plans and O I hereby certify that the Plans and spedfications covered by specance buns covered by this this calculation are in comp rtce will the bride Energy calculation indicates compliance y Code. with the Florida Energy Cade- G �- Before construction is completed PREPARED BY' this building will be inspected for �. c f--F� --- - compliance with Section 553.908 DATE: - — - '-f' I hereby certify dotis building,as designed lo compliance Flonda StatutesWE . '~COO t with the Florida Energy _ BUILDING OFFICIAL: OWNERIAGENT:- - DATE: ------- DATE: _—._---Ia _ Compliance requires cartficeton by dile air trendier unit manufacturer that the air handler enclosure qualifies as 84ion Ira,. ars'a.r/Land an C COPY leakage comped factorysealed in acwrdarrce wit lotion Checklist in accordance with y�Fiy`L compliancert m accordance Air orderR402.a.1 y nsula0on Insprycton �/r test repo REVISION BP# /6—SFfF T—!e/P DATE6 / a-PJ GI Pam 1 of 5 Mile Ener9YGaugeN USA-FTWae2014 Section 9M i)14 1011312016 6:45 PM ��— FORM R405-2014 PROJECT Title: ECHun61 Bedrooms'. 3 Address Type: Street Address Building Type: User Conditioned Area: 1518 Lot# Owner: Lamberton Total Stories: 2 BlorR/SubDlytion: #of Units: 1 Worst Case: No PlalBook: Builder Name: Elite Custom Homes and Ren Rotate Angle: 0 Street: Donner Rd Permit Office. Cross Ventilation: County: Duval Jurisdiction: 261100111 Whole House Fan: City,Stat,LP: Jacksonville, Family Type: Multifamily FL, New/Existing: New(From Plans) Commerd: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Localim TMY SOO Zau 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jaticsomille FL_JACKSONIALLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Nu bw Nal Area Voame,. 1 Bldutl 1518 121" SPACES Number Name Area Va6me Klben Omyeus Bedrooms Infill ID Finished Cooled _ Heated 1 Lying Real 340 2720 No 2 1 Yes Yes Yes 2 Dining Room 238 1904 No 2 0 1 Yes Yes Yes 3 Kitchen 170 1360 Yes 2 0 1 Yes Yes Yes 4 Bedroom 3 180 1440 No 0 1 1 Yes Yes Yes 5 Bedroom 280 2240 No 0 1 1 Yes Yes Yes 6 Bamroan1 140 1120 No 0 0 1 Yes Yes Yes 7 Bedroom 1 170 13W No 0 1 1 Yes Yes Yes FLOORS i Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value _ Tile Ward Camel 1 Slab-On-Grade Edge Insuletio Living Boom 37 R 0 340 IF — 0 1 0 2 Slab-OrvGrede Edge Insulatio Dining Room 10ft 0 238 IV — 1 0 0 3Sleb-On-Grade Edge hsuWts Kitchen 106 0 170W -- 1 0 0 4 Floor Over Other Space Bedroom 3 ISO 6' 0 0 0 1 5Floor Oyer Other Space Bedroom 2 2386' 0 0 0 1 6 Floor Over Other Space Bauroan1 _ — 1196' 0 0 0 1 7 Floor Over Other Space Bedroom —_ _ 1706' 0 0 0 1 8Raised Floor Bedroom _ — 426' 19 0 0 1 9Raised Floor Bathroom 1 — — 21 If 19 0 0 1 1011320165:53 PM EnergyGauge®USA-FleRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 ROOF Roof Gable Roof Solar SA Emitt Emelt Deck Pilch V 8 Type Materials Area Area Color Absa. Tested Tesler) Insul. (deg) 1 Hip Composition shingles 1637M OR Medium 0.96 No 0.9 No 0 22.6 ATTIC V R Type Ventilation Vent Ratio(1 in) Alen RBS IRCC N 1 Full aBic Vented 300 1511112 N _---- -- CEILING i« -Calling Type _ Space R-Value Ina T _ YVe Area Fmrni,g Frac Trams Type 1 Untler AlBc(Ventetl) Living Room 38 Blown 7 ft. 0.17 Wood 2 Under ABic(Venied) Dining Room 38 Blown 182 0.11 Wootl 3 Under AOb(Vented) Kitchen 38 Blown 182 0.11 Wood 4 Under Attic(Vented) Bedroom 38 Blown 18082 0.11 Wood 5 Under Attic(Verand) Bedroom 38 Blom 28082 0.11 Wood 6 Under ABk(Varied) Bathroomt 38 Blown 140fl 0.11 Wood 7 Under Attic(Vented) Bndroon1 38 Blown 17082 0.11 Wootl WALLS Adjacein Cavity Width Height Sheathing Framing Solar Below ill To Wall Type _. _ Space-Value._ Ft In Ft in .Area_ -Value Fracion Absor_ Gradi _ 7 S Garage Frame-Wood Kitchen 19 17 8 136.082 0.23 0.75 0 _2 W Exterior Frame-Wood Kitchen 19 10 8 80.082 0.23 0.75 0 3 W Eiden. Frame-Wood Dining Roan 19 14 8 172.0 82 0.23 0.75 0 4 W EMenor Frame-Wootl Living Room 19 20 8 160.08 0.23 0.75 0 -5 N Fxletlor Frame-Wood Living Rerun 19 17 8 136.082 0.23 0.75 0 6 S Exterior Frame-Wood Bedroom 1 19 17 8 136.082 0.23 0.75 0 _ 7 W Eiderior Frame-Wood Bedroom 19 10 8 80.082 0.23 0.75 0 _ 8 S Enlenior Frame-Wood Bathroom) 19 3 8 24.082 0.23 0.76 0 9 W EA dor Frame-Wood Bathroom1 19 7 8 58.082 0.23 0.75 0 _10 W Exterior Frame-Wootl Bedroom 19 14 8 112.082 0.23 0.75 0 _11 N Eiderior Frame-Wood Bedroom 19 3 8 24.082 0.23 0.75 0 _12 W 6leror Frame-Wootl Bedroom 19 10 6 8 84.OfF 0.23 0.75 0 _73 N Exlendr Frame-Wood Bedroom 19 17 8 136.082 023 0.75 0 DOORS Y Ord Door Type Space Storms U-Value WM __.._ Ft In Ft NIn Am 7 W Insulatedl Dinir9 Room Nora .46 3 8 2482 10/132016 5:53 PM EnergyGaugeS USA-FlaRes2014 Section R405.4.1 Compliant Schwalm Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Oral ID _Frame Panes NFRC U-Factor SHGC Area _ Depth Separation _ Int Shade Screening 1 W 3 Vinyl Double(Tinted) Yes 0.35 0.3 25.00' 1R6 in 8110 in Drapeslbliuds None 2 W 4 Vinyl Doubk(Tintad) Vas 0.35 0.3 25.0 R' 106 in 800 in Drapes/blinds None _ 3 N 5 Vinyl Double(Tinted) Yes 0.35 0.3 48.0 ft' 1It6 in 800 in Drapesrolinds None _ 4 S 6 Vinyl Double Twil yes 0.35 0.3 15.00' 1R6 in 600 in Drapeslblinds None _ 5 W 10 ViMI Double(Tinted) yes 0.35 0.3 15.0 R' f06 in 600 in Drapes/blinds None 6 N 13 Vinyl Double(Tinted) Yes 0.3 0.35 15.00' 106 in 600 in Drapes/blands None GARAGE i Flw Arm Ceiling Area Exposed Wall Perimeter Avg.Wall Height_. Exposed Wall Insulation 1 3361F 336 it' 641 a 0 1 INFILTRATION i Scope McOtod SEA CFM 50 EEA EgtA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000246 978.9 53.74 101.06 .2331 4.8383 HEATING SYSTEM i System Type Subtype Efficiency Capacrty Block Ducts 1 Electric Heat Pump None HSPF'.8.5 36 kStu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER 15 36 kBtmm 1080 chn 0.75 1 sys#1 HOT WATER SYSTEM i System Type SubType Location_ EF Cap Use Scalpel Conservation 1 Elaxab None Kitchen 0.95 40 gal 60 pal 120 deg None SOLAR HOT WATER SYSTEM FSEC Coue Swrape Cent # Company Name System Modell Collector MadeU Mea Volum, FEF None None 0' DUCTS —Supply— —Retum— Mr CFM 25 CFM25 HVAC0 1/ i Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF I" Cool 1 Attic 6 1800 Attic 400' Dei Leakage SalhmomI (Delal (Oetal 1 1 10/13/2016 5.53 PM EnergyGaul USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programablling [e,Thermostat.Y FebfU0f(( I CEreiling Fans:fp( r00I Jul t0( t�0' Oct (�(%�]] HD- Healitilar nq HJJan anJan HFeb 0iMar [ �MeyJell [ ,Jul ` � [ ] Oct� l%l Hoy � VDec enting 11111 Arg Bao ' Thermostat Schedule: HERS 20W Reference Hours SdieEule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 56 66 68 fib 68 68 68 68 68 PM 68 68 68 68 68 68 68 88 68 68 66 66 Headng(WEH) AM 66 66 66 66 66 68 68 68 68 68 6' '' PM 68 fib 68 68 68 68 68 68 68 68 66 66 10/13120165:53 PM EnergyGauge®USA-FlaRes2014Section R405.4.1 Compliant Software Page 5 of FORM RQF5 2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 91 The lower the EnergyPerformance Index, the more efficient the home. Donner Rd, Jacksonville, FL, 1. New construction or existing New(From Plans) 9. Well Types Insulation Area 2. Single family or multFraiple family Multi-(amity a.Frame-Wood,Exterior R=19.0 1140.00ft b. me-Wood,Adjacent R= ft Number19.0 136.00 it 3. of units,it multiple family 1 c.NIA R= It, 4. Number of Bedrooms 3 d.WA R= It 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 773.00 ft 8. Conditioned floor area(1119 1518 b.WA R= It c.WA R= ft' 7. Windows" Description Area 11.Duds R ft' a. U-Fedor. Diol,U=0.35 128,00 ft' a.Sup:Attic,Ret:Attic,AH:Bathroom 1 6 180 SHGC: SHGC=0.30 b. U-Fador. Dbl,U=0.30 15.00 ft' SHGC: SHGC=0.35 12.Cooling systems kBtu/hr Efficiency c. U-Factor: WA ft' a.Central Unit 36.0 SEER:15.00 SHGC: d. U-Fac ar: N/A ft' 13.Heating systems kBhahr Efficiency SHGC: a.Electric Heat Pump 36.0 HSPF:8.50 Area Weighted Average Overhang Depth: 1.500 It Area Weighted Average SHGC: 0305 e. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0o 748.008' a.ElectricEF:0.95 b.Floor Over Other Space R=0.0 707,00 It b. Conservation features c.other(see details) R= 63.00 ft None 15,Credits CF,Peter I certify that this home has complied with the Florida Energy Efficiency Code for Building OFq'11E Srg7� Construction through the above energy saving features which will be installed(or exceeded) y = < o in this home before final inspection. Otherwise, a EPL Display Card will be completed based on installed Code pliant features. Builder Signature: q Date: (0111k, Address ofN o : _�,?I lac✓NCity/FL Zip: fL 37,7,33 •� s CDOWEfQ `Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10173/2016 5:53 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Donner Rd permit Number: Jacksonville FL, MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy Performance level(EPL) display card be completed and certdfied by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verily that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display cath can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be conatructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402 4.4, Q R402A.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1 2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturers instructions and the criteria listed in Table 402 4.1.1,as applicable to the method of construction. Where required by the code official,an approved third parry shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes Per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the mite official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doom,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration mrnmi measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed but not sealed beyond intended infi0ration control measures; 3.Interior doom,9 installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed 5.Heating and cooling systems,if installed at the time of the test,shall be turned off,and 6.Supply and return registers, 4 installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New mod-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windom,skylights and sliding glass tloors shall have an air infiltration rate of no more than 0.3 cim per square bot(1.5 UshnZ,and swinging tloors no more than 0.5 cfn Per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA WDMArCSA 10VI.SMA440 by an accretliled independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limb air leakage between conditioned and unconditioned spaces.All recessed luminaires shall he IC-rated and labeled as having an air leakage rale not more than 2.0 arm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential,All recessetl luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Themrostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary eledric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)AII duds,air handlers,and fitter boxes and building cavities that forth the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section G403.2].2 of the Commercial Provisions of this code ant shall be shown to meet dud tightness criteria by post-construction or rough-in testing below. Dud tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as eulhaized by Florida Statutes,to be"substantially leak gee•by either of the following: 1. Posbconstrudion test:Total leakage shall be less than or equal to 4 cm,(113 Umin)per 100 square feat(9.29 m2)of conditioned floor area Men tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturers air handier enclosure.All register boots shall be taped or olhewdse sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 arm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturers air handler enclosure.All registers shall be taped or otherwise sealed during the and.If the air handier is not installed at the time of the lest,total leakage shall be less than or equal to 3 cfn (85 Umm)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handles located entirely within the building envelope. 2. Dud testing is not mandatory for buildings complying by Section 8405 of this code. I Wl320165:53 PM EnegyGauge®USA-FlaRes2014 -Section R4054.1 Cam Page 1 of FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities IMandatory). Building framing cavities shall not be used as duds or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of RJ., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn o6 the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and mid water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 14PF(38-C to 600C). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumehs) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.I. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Mathods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hol Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a lilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventixilion(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submided along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safely factors,provisions for future expansion or other factors which affect equipment aging.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 cooling equipment capacity. Coaling only equipment shall the selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected In Section 403.6,or the closest available size provided by the manufacturers product lines.The corresponding latent capacity of the equipment shall not he less than the calculated latent load 10/13/2016 5:53 PM EnergyGauge®USA-FlaReni -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,mong-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity,used for the load calculation and shall be adjusted for return side gains if the return ducts)is installed in an unconditioned space. Exceptions: 1. Attached single-and mufti-family residential equipment sizing may be selected so that its cooling capacity is less than the calculatetl total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Flonda-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. 0 R403.6.1.2 Heating equipment Capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the Cooling requirements as calculated according to Section R403.6.1.1 and the heal pump total Cooling Capacity shall not be more than 1.15 times greater than the design Cooling load. R403.64.2.2 Electric resistance furnaces. ElecMc resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The Capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403 6.1. 0 R403.6.1.3 Extra Capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads Caused by major entertainment events,shall have equipment sized or Controlled to prevent Continuous space Cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall Comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-mefting systems,supplied through energy service to the building,shall include automatic controls Capable of shutting off the system when the pavement temperature is above 55•F,and no precipitation is falling and an automatic or manual Control that will allow shutoff when the outdoor temperature is above 40•F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O 8403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. 8403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.66. Pool heaters fired by natural gas or LP gas shall not have Continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. 0 R403.9.2 Time switches. Time switches or other Control method that can automatically tum off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public heats standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are poweretl exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground Permanently installed spas shall be equipped with a vapor-retardant Cover on or at the water surface or a Ilquld Cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source Computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall Contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy,lamps. O R404.1.1 Lighting equipmenl(Mandatory). Fuel gas lighting systems shall not have Continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R6. 0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficenl space,R-10 is allowed. 10/1312016 5:53 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ECHun@1 Builder Name: Elite Custom Homes and Renovations street: Donner Rd Permit Office. City,State,Zip: Jacksonville,FL, Permit Number Owner Lambenson Jurisdiction: 261100111 Design Locaaon: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air banner shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceding/softil shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substanfial contact and continuous alignment with the air banier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air banner. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subficor decking. The air banner shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I ,v/ vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow,cavities shall be filled by insulafion that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily confirms to available -V/ space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air bamer installed separating them from the showers and tubs. ElectrlcaUphone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. v HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. FileplaCe An air barrier shall be installed on fireplace walls. Fireplaces shall have Basketed doors 10/13/2016 5:53 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: ECHunilt Builder Name: Eldo Cuslom Homes and Renovations Street. Donner Rd Permit Office: City.State,Zip: Jacksomi Ft , permit Number Design Location: FL,Jacksonville Judsdiclion. 261100111 Cond.Floor Area.: 1518 sq][. Cond.Volume: 12144 cuR. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: -- -. n: R: CFM(50) Single or Muld Pant Test Data HOUSE PRESSURE FLOW: ELA. 1 Pa cm EgLA: 2 Pa cfm ACH. 3 Pa cfm -- ACH(50): 4 Pa cfm -...-5 Pa cfm SLA: 6 Pa Gm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the resu0s of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weathersMpping or other infiltration control measures; 2.Dampers including exhaust, intake,makeup air,bac draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doom,if installed at the time of the test,shall be,open; 4. Exterior doom for continuous ventilation systems and heal recovery ventilators shall be closed and sealed; 5.Healing and cooling systems,if installed at the time of the lest,shall be,tumed off,and 6.Supply and return registers,0 installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, OFtBE ST4T� performance results demonstrate compliance testing shall be conducted by an �' , _ _ , Qn with Florida Energy Code requirements in approved third party. A written F °'•, '"ro accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party � -/ conducting the test and provided to W . SIGNATOR' -4E: J ?2rw(_Y/ the code official. J ° PRINTED'NAME: ��M CpO WE DATE: �� /�� �� 14 BUILDING OFFICIAL: DATE: 10/13/20165.53 PM Eneigy(Saugi USA-FlaRes2014 -Section R405.4.1 Compliant Software Pagel oft Project Summar Job: Jun 06,2 1 Y Dare: Jun 06,2016 Entire House By: Monlcas.Bacca Pro6ect Information For: Lambertson, Elite Custom Homes and Renovations Donner Rd,Atlantic Beach, FI Notes: Design Information Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 `F Outside db 93 "F Insidedb 68 "F Inside db 75 "F Design TD 36 "F Design TO 18 "F Daily range M Relative humidity 50 Moisture difference 52 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16970 Btuh Structure 18914 Btuh Ducts 5247 Btuh Ducts 8702 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Stun Slimier 0 Btuh Piping 0 Btuh Equipment load 22216 Btuh Use manufacturer's data y te/ Raswing muHiptier 1.00 Infiltration Equipment sensible load 27616 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3141 Btuh Ducts 1781 Stun Head ng cooling Central vent((0 cfm) 0 Stun Area(fl') 1576 1576 Equipment lafenl load 4922 Btuh Volume(W) 12608 12608 Air changes/hour 0.50 0.26 Equipment total load 32538 Btuh Equiv.AVE(cOn) 105 55 Req.total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Ruud Make Ruud Trade RUUD Trade RUUD Model RP1536AJlNA Cond RP1536AJINA AHRI ref 7512115 Coll RHJT3617STANAA AHRI ref 7512115 Efficiency 9 HSPF Efficiency 12.5 EER, 15 SEER Heatingin Sensible coding 24920 Btuh Heatinoutput 33800 Btuh @ 47°F Latent coding 10880 Btuh Temperature rise 25 -F Total cooling 35600 Btuh Actual air flow 1187 cfm Actual air flan 1187 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance pomt= 20°F Backup. Input=6 kW, Output= 18955 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. R' RgMSuBeeUniversalIDt]11.0.0•RSU12595 a1160c1-181Pp: z• Wrlght50 AC5S ...ka%D=uments%V*VMewI HWC\Demo%ECHunnl.mp C•Io=MJ8 FmM Dowftc : S Load Short Form Job: EDltunkl BCCA Date: Jun O8,2018 Entire House By: Moniw B.Bacca Project For: Lambertson, Elite Custom Homes and Renovations Donner Rd,Atlantic Beach, FI Design Htg Cig Infiltration Outside db(°F) 32 93 Method Simplified Inside db('F) 68 75 Construction quality Average Design TD (°F) 36 18 Fireplaces 0 Daily range - M Inside humidity (h) 50 50 Moisture difference(gr/Ib) 30 52 HEATING EQUIPMENT COOLING EQUIPMENT Make Ruud Make Ruud Trade RUUD Trade RUUD Model RP153SAJINA Cond RP1536AJlNA AHRI ref 7512115 Coil RH1T3617STANAA AHRI ref 7512115 Efficiency 9 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24920 Btuh Heating output 33800 Btuh @ 47°F Latent cooling 10680 Btuh Temperature rise 26 °F Total cooling 35600 Btuh Actual air flay 1187 cfm Actual air flow 1187 cfm Air flow factor 0.053 cfm/Btuh Air flaw factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point= 20-F Backup: ROOM NAME Area Htg bad CIg load Fig AVF CIg AVF (82) (Btuh) (Btuh) (cbn) (cfm) Living Room 340 9510 11768 508 506 Dining Roan 238 3368 6052 180 260 Kitchen 170 1898 2774 101 119 BR3 236 2513 1723 134 74 BR2 280 1823 3072 97 132 Baths 140 916 541 49 23 BRI 170 2189 1686 117 72 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. a1l6 -181221448 + wrightSOft' RyM.4 UN.•a MW1717009R5UUW P•aet OCiCA _.ce\Da MWS\NWdhbW1HWC\Demo\ECHundt.mp Cant=MJB `m Dm faces. 5 Entire House d 1576 22216 27616 1187 1187 Other equip loads 0 0 Equip. @ 1.00 RSM 27616 Latent cooling 4922 TOTALS 1576 22216 32538 1187 1187 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed, AI118 12:14'.28 + wrightSOft Rqm d. UnW .Aron 17 o M RSu12588 R.a.2 14CCitl .. Calc-MJS Fm'X000f- .. S Manual S Compliance Report Job: ECHun,H P P Jun 06.2016 By: Entire House By: MD^Ira s.aBnDB Project Information For: Lambertson, Elite Custom Homes and Renovations Donner Rd,Atlantic Beach, FI Cooling Design Conditions Outdoor design DB: 92.8'F Sensible gain: 27616 Btuh Entering coil DB: 77.6'F Outdoor design WB: 77.3'F Latent gain: 4922 Btuh Entering coil WB: 63.8'F Indoor design DB: 75.0'F Total gain: 32538 Btuh Indoor RH: 50% Estimated airfim: 1187 cfm Manufacturees Performance Data at Actual Design Conditions Equipmemtype: Split ASHP Manufacturer: Ruud Model: RP1636AJ1NA+RH1T3617STANAA Actual airflm: 1187 cfm Sensible capacity: 28900 Btuh 105%.of load Latent capacity: 5430 Btuh 110%of load Total capacity: 34330 Btuh 106%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 31.8'F Heat loss: 22216 Btuh Entering coil DB: 67.3F Indoor design DB: 68.0'F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Split ASHP Manufacturer: Ruud Model: RP1536AJ1NA+RH1T3617STANAA Actual airflow: 1187 cfm Output capacity: 25300 Btuh 114%of load Capacity balance: 20 'F Supplemental heat required: 0 Btuh Economic balance: -99 'F Backup equipment type: Elec strip Manufacturer: Model: Actual airflm: 1187 cfm Output capacity: 5.6 kW 85%of load Temp. rise: 50 'F Meets are all requirements of ACCA Manual S. 2018-0[1-1812:16'38 Wrig11t5Oft* RgMSuft OunwmWW1717.0.091RSU12095 Ppe1 Ica\Documents\ ghtsdt HVAC\Demo\ECHunftl.mp CW=MJB Fwl Doxf c : S ,t RPER- Review , h/'7Vl/Itl1� 261100 III Header Information Connector: REDUIREDATTACHMENTS ATTACHED Manual J1 Form(and supporting warksheets): Yes [3 No 0 Mechanical license: or Mi Form'(and supporting worksheets): Yes E] No [] OEM performance data(heating,cooling,blower): Yes E] No [3 Building plan#: Manual O Friction Rate Worksheet: Yes [] No E] Duel distribution sketch: Yes 0 No E] Home address(Street or Lotli,Block,Subdivision): Donner Rd, Entire House HVAC • • ■ CALCULATION (IRC W401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 32 T Orientation Front Door faces South Indoortemperature: 68 7 North,asset West,seats,......ask....t.Sessu .r Total heat loss. 22216 Ruh Number of bedrooms: 3 Conditioned floor area: 1576 fl' Summer Design Conditions Number of occupants: 6 Outdoor temperature: 93 `F Indoor temperature: 75 °F WindowsGraNoo Sensible heat gai 52 ry/lb 16 RH Eavewsrhanghade.tlepM: e fl Sensible heat gain: 27616 Ruh Internal shatle: none sen Latent heal gain: 4922 StuN esw..a,.w.,em. orolh woew Total heat gain: 32538 Ruh Number of skylights: 0 EQUIPMENTHVAC • 1 Heating Equipment Data Cooling Equipment Data Blower Data Egumpmem lite: Split ASHP ETAS—nlpe' SpIRASHP Heating cfm: 1187 ,xe wNs.eorenec. r ah de.n wne.em' Cooling ohn: 1187 Model Ruud Model: Ruud StMiy .is. .iaineLneTE PR in H2O RP1536A11NA-RH1T3617STANAA RP1536AI1NA+RH1T3617STANAA aais epo.wlow Healin%gutput capacity: 42$300 9tuh Total cooling capacity: 34330 Ruh xmv a se-c.wcry is vers"a. no c anion, Sensible coolingtycapacity. 28900 Ruh ux A .heating output capacity 18955 Ruh Later cooling capwipaciy. 5430 Bluh HVAC DUCT-DISTRIBUTION SYSTEM ■ .1 Design airflow: 1187 cfm Longest supply duct 151 It Duct Materials Used Equipment design ESP. 0.50 it H2O Longest return duct: 67 fl Trunk duct: Round flex vinyl Total device pressure losses: -0.2 in k12O Total e#ed.large,RELk 241910 8 fl Available static pressure(ASP): 0.31 in H2O Friction M ries xate-nu+l*R.i DomlBranch duct: Round flex vinyl I declare the load calculation,equipment,equipment selector,and duct design were rigorously performed based on the IbUild i o plan listed above. I understand the claims made on these forms will be subjengto review and verification Contractor's printed name:Contractors signature: v (` Date: T Reserved for County Town!Vlunoir �v or Authority having jurisdiction use 'Home qualifies forMlForm based on Abridged Edition Checklist WnpryhtSOft- RightSUXe9un er al20171]O.re RSU12595 N Level 2 BR3 66 dm 134 d. 1•• 66 kn up Riser cfm 6. 24 dm Bath 17 dm BR1 Job#: ECHunitl Scale: 1 : 97 Performed by Monica S. Bacca for: Page 1 Lamberlson RightSuiee Unnasal 2017 Donner Rd 17.0.09 RSU12595 Atlantic Beach,FI 2M1 -1612:16:29 _Aghlso6 WACU)e=l CM.11.mp N Level 1 Living Room 254 2 _ 1187 cfm 6' 6' la up R eer Ding 30 6' 130 119 m Kitchen Garage Job#: ECHunitl Scale: 1 : 97 Performed by Monica S. Bacca for: Page Lamberison RghtSuke®Univ W12017 Donner Rd 17.0.09 RSU12595 Atlanto Beach,FI 2016-0 4812:16:29 rghlsoa WAQ =AECflunrl.wp Duct System Summa Job: Jun 06, Y Summary Date: Jun 06,2018 Entire House By: Monkas.B For: Lambertson, Elite Custom Homes and Renovations Donner Rd,Atlantic Beach, A Heading Cooling External static pressure 0.50 in H2O 0.80 in H2O Pressure losses 0.19 in H2O 0.19 in H2O Available static pressure 0.31 in H2O 0.31 in H2O Supply/return available pressure 0.215/0.095 in H2O 0.215/0.095 in H2O lowest friction rate 0.142 in/100ft 0.142 in/100ft Actual air flow 1187 cfM 1187 cfm Total effective length(TEL) 218 ft SupplyDetail Table Design Htg Clg Design Diem H x W Duct Actual Ftg.Egv Nene (Btuh) Will (cfm) FR (in) (in) Mail Ln(ft) Ln(ft) Trunk BRt In 2189 117 72 0.142 8.0 0x0 VIFx 28.9 1220 st1 BR2 c 1536 49 66 0.144 6.0 0x0 VIFx 26.5 122.0 st1 BRLA c 1536 49 66 0.143 4.0 0x0 VIFx 28.2 122.0 st1 BR3 h 2513 134 74 0.143 7.0 0x0 VIFx 27.8 1220 st1 ell In 458 24 12 0.144 4.0 Oxo VIFx 25.5 1220 st1 Bal In 458 24 12 0.145 4.0 NO VIFx 26.4 122.0 SO D.t+tg Rave c 3026 90 130 0.180 &0 Ox 0 VIFx 122 122.0 st2 Dill F.-A c 3026 1 90 130 0.157 I.0 0x0 VIFx 14.3 1220 st2 xuanen c 2774 1101 119 0.154 &0 Ono VIFx 17.1 122.0 st2 [Wing Reran IN 4755 254 253 0.158 &0 Ono VIFx 14.1 122.0 st2 rJvay R.A In 4755 254 253 0.157 &0 0x0 VIFx 1 14.7 1 1220 st2 SupplyDetail Trunk Htg Clg Design Veloc DiamH x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 397 302 0.142 506 120 0 x 0 VinlFlx 5t2 Peak AVF 789 885 0.154 0 120 8 x 0 VirdFix amC/bblc value:pare been,nanumryo rr;nn- 2016Cct-1812'.14:28 I& Wrnghl Rgpt-Suae0Uni-al201717003RSU12.5 Paae1 I& _.Ica\DMUMeV0WtgMSWt HVAC\Dvvo\ECHundl mp Cale=MJ8 Faant 0m fa ea 5 Return Branch Detail . - Grille Htg Clg TEL Design Vebc Dian H x W Stud/Joist Duct Nene Size(in) (cftn) (tiro) (ft) FR (fpm) (in) (in) Opening(in) Mail Trunk rb2 1 0.0 1 1187 1187 67.1 1 0.142 672 18.0 Ox 0 1 VIFx 201 u -te 12a4M * wrightsofC agms.ft a unw.n.m M1717.o.CQ RSUMO awe s _kMDo.U..MWNht.on HUO.G\ ..m CHUWi p CM.=MJ9 FSM D.,f...: S