720 PARADISE LN - PERMIT C ''c � CITY OF ATLANTIC BEACH ' 800 SEMINOLE ROAD 7:1" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Ji2l`-)%' ________2 SINGLE FAMILY DWELLING NEW MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFR-1744 Job Type: SINGLE FAMILY RESIDENCE Description: new single family home Estimated Value: $307,020.00 Issue Date: 8/22/2016 Expiration Date: 2/18/2017 PROPERTY ADDRESS: Address: 720 PARADISE LN RE Number: 172376-0235 PROPERTY OWNER: Name: SPRINGFIELD BUILDERS LLC Address: GENERAL CONTRACTOR INFORMATION: Name: SPRINGFIELD BUILDERS LLC Address: 1881 BEACH AVE RALPH BUCK DAVIS Phone: - - PERMIT INFORMATION: FEES: ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $550.53 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $1,101.06 STATE DCA SURCHARGE $16.52 STATE DBPR SURCHARGE $16.52 a- I`ISA PAS*71 Y§Z 'IIS MRDANCH:1` 1915QI:i" (ITY OF ATLANTIC BEACII ORDINANCES AND THE FLORIDA ICHI@NG CODES. 'r�i rL�l f�rY p,, !;\ CITY OF ATLANTIC BEACH N • s) 800 SEMINOLE ROAD .5 ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 WATER CONNECT/TAP & $185.00 METER WATER CROSS CONNECTION $50.00 WATER SDC-SYSTEM DEV $1,140.00 CHG Total Payments: $7,259.63 PERMIT IS APPROVED ONLY IN ACCORDANCE: 11'1111 ALL CITY OF ATI %N77(' BEACH ORDINANCES AND 771E FLORIDA BL ILDING CODES. J s=- 143 City of Atlantic Beach APPLICATION NUMBER A Building Department ; j 800 Seminole Road C E I� Phone(904)247-5826 • Fax(904)247 845 (To be assigned by the Building Department.) -, Atlantic Beach, Florida 32233-5445 UG 2 2016 ` (Q SF(L— 11-4`1 1 •,1•"...g1110- �1Jr E-mail: building-dept@coab.us Date routed: at'11:) r L 110 City web-site: http://www.coab.us By: APPLICATION REVIEW AND TRACKING FORM Property Address: -ka D I Q,ratSt S.& L\ . Department review required Yes No Building_ -1,„.� Applicant: 5pr l nP.L)4 Qut 14-LIS Project: Panning &Zoning) 1" Tree Administrator hp fl IJ $t(�!�`;L �anl� �u At u IicWorks . v t Public Uti i ies Public Safety Fire Services Review fee $ 3--J Dept Signature ,-yam Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District - Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ['Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING 1 e , ,// � s 7c, Reviewed by: v�' . Date: �� TREE ADMIN. Second Review: []Approved as revised. ['Denied.aWKSORComments: �!' -BLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: ised 05/14/09 I iI 'I, • City of Atlantic Beach 's r APPLICATION NUMBER ! 1 Building Department 1V $ To be assigned by the Building Department.) =� ti; 800 Seminole Road 3� �r Atlantic Beach, Florida 32233-5445 AUG 0 2 2016 I SF�— 11-4H • • Phone(904)247-5826 • Fax(904)247-58 ' 0109- E-mail: building-dept@coab.us Date routed: 04111) I 110 City web site: http://www.coab.us BY: APPLICATION REVIEW AND TRACKING FORM Property Address: -ka 0 p&tcx4-t Lc_LA . _ D- . . tment review required Yes No Building Applicant: Sp(In 4.. 1.Q Qui tat/3 4 P1a`nning &Zonin. Tree Administrator Project: nLu„) Slnp_ amt ty horitt _ -u.lic Work Public Utilities. Public Safety Fire Services Review fee $ Dept Signature • Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. ❑Denied. (Circle one.) Comments: fee /19$4444 94if n /'.04 BUILDING .(i li G PLANNING &ZONING �,� // //Z/ Reviewed by:___. "" Date: TREE ADMIN. Second Review: []Approved as revised. ❑.-nied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: ised 05/14/09 t#LZC fi dr z171-a,644--- -1,,e4-17Y7( L a /az X sS.1' f/7/0 1eme q�z ado/ e s .242/ X6,3 X 3. .,1' t1:13 17,17 ri !3. 69 X 1 BuIcPaPrh ,i3Z 67 kik 21.rf - ,rip_114a x /5 //lc �6� - Y , •75(-1 w TREE REMOVAL PERMIT 1, i f City of Atlantic Beach �, Building and Zoning Department 800 Seminole Road Atlantic Beach,Florida 32233-5445 "=(-0,319%• Phone: (904)247-5826 Fax: (904)247-5845 Email: Building-Dept@coab.us Permit: 1 6-DRTV-93 Applicant: Springfield Builders Address: 13846 Atlantic Blvd#204,Jacksonville,FL 32225 Site Address: 720 Paradise Ln Phone: (404)626-0245 RE#: 172376-0235 Email: Ralph.buck.davis@gmail.com TREE RE OVAL CALCULATIONS REMO D Legacy(non-oak) Legacy(oak) Oaks Palms Others Total Protected Tree. Removed: 0 60 15 10 14 99 Mitigat on Needed: 0 30 7.5 5 7 49.5 Tre- Removed: 10"Palm, 14"Pine,31"Oak, 15"Oak,29"Oak MITIGA ION Legacy(non-oak) Legacy(oak) Oaks Palms Others Total Credit for Tree. Preserved: 0 0 4 0 0 4 Credit for Tree•Relocated: 0 0 0 0 0 0 Credit for Tr,es Planted: 0 16 0 24 0 40 Total: 0 16 4 24 0 44 Trees Preserved: 4"Oak Trees Relocated: None. Tre-s Planted: 2-4"Oaks,2-12"Palms.* *Planted Legacy Tree species receive DOUBLE credit when replacing non-Legacy Trees. The Legacy Tree list includes Bald Cypress; Si uthern and Eastern Red Cedars; Winged and Florida Elms; Live and Sand Live Oaks; Hickory; Pecan; Pignut Hickory; I oblolly Bay;Southern and Sweetbay Magnolias;Red and Florida Maples;and Tupelo. ADDITIO • MITIGATION REQUIRED (Mitigation Needed--Total) Legacy(non-oak) Legacy(oak) Oaks Palms Others Total New Tr:-s Planted: 0 5.5 0 0 0 5.5 or Payment Into I ree Fund: $0.00 $676.50 $0.00 $0.00 $0.00 $676.50 or A Combination o the Above Additional Notes: Mitigation is 1 inch preserved or planted for every 2 inches removed. Tree Fund rate is $123.00 per inch. Also preserving 30"Oa 9"Palm,7"Oak,27"Oak,40"Oak. Status is in accorda ce •rth the City of Atlantic Beach code of ordinances in effect at the time of application submittal. APPROVED E DENIED 0 f?71. - q41-‘12/-- Jeremy H'ubsch,TPO ADMINISTRATOR DATE o--•>n, City of Atlantic Beach APPLICATION NUMBER rl < Building Department �. (To be assigned by the Building Department.) -•;4� k, 800 Seminole Road J� "r Atlantic Beach, Florida 32233-5445 (Q� SF�_ ���}� Phone(904)247-5826 • Fax(904)247-5845 1 ' uniur E-mail: building-dept@coab.us Date routed: OVI0 - `t ID City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: --A-a D pa,ra.at S,L LA . Department review required Yes No (Building Applicant: 5pr;n9 P.c,4 Qut t.aids _ Planning &Zonin Tree Administrator Project: nR,t.J S111�\� a(ht 14 hones u lic Works Public lb i ies Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco . Other: APPLICATION STATUS Reviewing Department First Review: ,Approved. ['Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by; 00e.,&„,,,7 8/(3//% TREE ADMIN. Second Review: I [Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: ised 05/14/09 -,4z-ei SO: CI 'WI n1 I\ yqck' JObCO 'r y PLAN US T BE I oQ 1m f „ , o U I ,0Z =„l :TIV33S a / ...-TIC.a„ 3 j � _.. ._ :_ cl o F o � �- o V co by rn F o� = o ici ti 2 -, �,� Z (411-bi O Iri w c cn ; c_n Q 1 W 33 / 4 mrn 7� 1— U c ` C „C—, w v 0 Q Cp i_r� W _. I, r1 ��0� -� y J 11.).:::,CCI Z ••O w Ao > II O� N^ N N ' F.a�, ^ I 1 "ca. 4403-4EA,4 i,,,Arly -iiii,-..,l'iN, 1411 o ,00.3.01 3„6Z SZ1N ;,,,, , .s `•% 1 w• .��+ �.moi• \� � 1 00 rn mow 1,, _÷.... ---- k.1.11.- ,...k ,,,1101111 r( 440111P” I i t I \—t--__ i .L......10.0e.'' i\ • I) • - v-- 1 ,Oi;ep z-3- \ is 5 / w / t , O U z— d --.......,....--.......,....../� - z a- p to I e 4' MI. 1 I f 11--.7.-1---.1 m �v.oo ^�t��- ii off. { -?? o ` 3 '-Aia� � [sb::r S 07 tiji) B. i / ` f. ag • 4 ,00701 3„6Z,15:Z1N Io a �m �o VI”cov cNi 33 rn CO cr) k CZ Ek- o QZ /� \ l2 A /i x000 ,. m , v c7)fm 7n N D ('n ‘7,,,,,,,; w 7J O j = m - V w . ... o Z O .5. 00 m m �a f co rn -In o nN ?gym Z r = 7\ m q c. - -n© m 2 -.1 = W p] (/) m iv Z .M A n - k - si. CITY OF ATLANTIC BEACH PUBLIC UTILITIES V 1200 Sandpiper Lane ATLANTIC BEACH,FL 32233 '-t 01119 (904)270-2535 or(904)247-5874 NEW WATER/SEWER TAP REQUEST Date: g- 2 - /(o Project Address: ?ZD /7AiZ4 ),SG 69-AJ E No. of Units: / Commercial Residential V Multi-Family New Water Tap(s)&Meter(s) Meter Size(s) e/ New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# / - 5Fii- I7i/`f Water System Development Charge $ Q lzSewer System Development Charge $ OS-0. Water Meter Only $ / 5, 00 Reclaim Meter Only $ Water Meter Tap $ (notes) Sewer Tap $ Cross Connection $ 50, 40 Other $ TOTAL $ 5 VZS,CO APPROVED: Kayle Moore, PE SC (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED ,,:s=>>`lr,,, City of Atlantic Beach APPLICATION NUMBER r) '-;1 ,r; � Building Department i 800 Seminole Road (To be assigned by the Building Department.) D'i ;• Atlantic Beach, Florida 32233-5445 1 (0— SF(Z- 14-4' f Phone(904)247-5826 • Fax(904)247-5845 \ oni2 E-mail: building-dept@coab.us Date routed: Olt IDS l I to City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: gra D Paict4. S1- Ln . Department review required Yes o Building - ) Applicant: Spr;n old QutIa.L(S Planning &Zoning, Tree Administrator Project: nu,.) Sll\ kk- Tarok ly hones u lic Works (-Public Uti i ies Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: I 'proved. ❑Denied. (Circle one.) Comments: /� BUILDING V PLANNING &ZONING Date: .19-/6 "!6 Reviewed by: / / ` TREE ADMIN. Second Review: []Approved as revised. Deni . PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 I .. - L\i ' ' CITY OF ATLANTIC BEACH i., c 800 SEMINOLE ROAD �IrATLANTIC BEACH,FL 32233 N\ (904)247-5800 BUILDING DEPARTMENT REVIEW COMMENTS Date: 8.11.2016 Permit#: 16-SFR-1744 Applicant: Springfield Builders,LLC Site Address: 720 Sailfish Dr., AB Address: 13846 Atlantic Blvd.#204 Review: 1 Phone: 404-622-0245 RE#: Email: Ralph.buck.davisngmail.com Homeowner: Same Correction Comments: These comments are from 1 of 5 Departments that are reviewing this application. Ap• ation is disapproved for the following issues: V Re-submit product approval for the SILVERLINE WINDOWS. Only whole numbers are acceptable. For instance the FL-14911R6 does not exist in the system.The system does not recognize numbers with R values. When 14911 is entered it shows a FL14911R7 with ' 20 different windows listed under FL14911R7. Please choose the exact window number with the decimal point and nu ber after. The Same applies for the shingles FL # submitted.—' '.-//'/6 m V -u s mit 2 copies o a ega survey. Contractor shall give the proposed FFE on the site plan, sign and initial on 2 site plan copies. _' __—_— , ../.7.;(., Mike Jones Building Inspector/Plan Reviewer City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 Fax (990� v4 4/) 247-5845 l � C Iy'' 1 14 d CEJ ryv � v4.,\i J 'i 11 G t )'- l 1 ' �I�-- -.`' BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach FL 32233 FILE COPY - )t,...) 9" Office:(904)247-5826 • Fax:(904)247-5845 Job Address: r1 z� Gso-3,'S� fir-` z _ Permit Number: / S(�'2 y� Legal Description L- 38 e-r 0-&'•5 L.Rre_5 e rut - 0 3 g p t - RE# 1.7 Z 31 Z Valuation of Work(Replacement Cos $ Z-2-5iH ed/Cooled SF Z�15 c( Non-Heated/Cooled7 7 8 3S' 9 • Class of Work(Circle one).4110b Addition ' Alteration Repair Move Demo ool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial esidential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No /A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: n« n Florida Product Approval# S<-e 44-�- for multiple products use product approval form Property Owner Information ~ r> • • 11 Name: Sp,-1�r s-\a (---`. i C�-"5, 's-'� Address: 13 BAC. 1 �rt�'c '.--\- ...)k -2_, -1City Jack ,Alk State a l Zip 32.71-' -c Phone L c k ( 2 6-1-(4 5- E-Mail �aA.cL._ 6..,J<< 4c .Asn th‘..1 - cow wn or Agent (If Agent,Power of Attorney or Aiency Letter Required) WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Contractor Information: Name of Company: 5 a Qualifying Agent: \ ---c-,\c\ (S-k�(- .s Address: City State Zip Office Phone Job Site/Contact Number State Certification/Registration# C-g c_ 17_S 8 C 2_R E-Mail Architect Name&Phone# Engineer's Name&Phone# s { ,-,l .)y — 8. — 7\-10 1 Worker's Compensation .�� cc g 1 61 R xemp nsurer -ase mp oyees xplratron sate 'LL Application is hereby made to obtain a •ermit to do the work and installations as indicated. I cert5 that no wor : installation has commenc •' >$ rzor to the issuance of a permit an a 11 work will be petjo r meet the standards of all laws regulati co truction in this jurisdicti. a his permit becomes null and void f wor is not comm- within s •(6 months, or if construction or wo is spended or aba ed ��:2::13 period o six(6 months at any ti •after ork is comme c.% 1 understa d that separate permits must be se, red f.r Electric• " ' Plumbi i 2 2Signs, ells, oo/s,Furnaces, :of/ers, 'eate Tan a .• •it Conditio ers,etGi'/ / .2 LL,2 Signature of Propert Own- : / A j 1 _i Signature of Contracto • ti Befor me I ••#, this Day of C) c-A. (...-2 Before me this .Day • �.t, ZC) 1' !`' AsiNotary Public: - ' A;L Notary Public: i:,tt7f�'lt a R�1 cT�'���1 •' ' ii, ,�, ,., •s x M •,,MIS I N#FF 92495 n, I hereb I p '.:•;a,: EXPIRES:October 6,201'1WI •c,c.rc rat I/ ittWtBiarfig 3rami 'd this a.. ation and know the same to be true Ri. ., •,ceonatilniat ta<ieh4 . '• s d ordinan r ,;,i�(giii ti.t r�1t pt?Nd wi 1 be complied with whether specified herein or 1-.=-:--••- • of presum:`:•:J 1 rt tyigat Og t: fan:'I the provisions of any other federal, state, or ocal law regulating construction or the perform �:1"06n ciicr,tu'iL;my Public UndOf It s Rev.3/14/16 • FILE COPY DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions Review Initials/Date: /P .R..//./ Development Size Habitable Space 7 s' S, F. Non-Habitable 7 7 if Impervious area Miscellaneous Information Occupancy Group t - Type of Construction V 0 Number of Stories 2- , Zoning District Po li Max. Occupancy Load Fire Sprinklers Required Flood Zone Conditions/Comments: 4 !" 7COPY - --- - TREE REMOVAL PERMIT '' ;0 . l City of Atlantic Beach j '4' Building and Zoning Department \� 800 Seminole Road Atlantic Beach,Florida 32233-5445 ` UFi1>'r- Phone: (904)247-5826 Fax: (904)247-5845 Email: Building-Dept®coab.us Permit: 16-DRTV-93 Applicant: Springfield Builders Address: 13846 Atlantic Blvd#204,Jacksonville,FL 32225 Site Address: 720 Paradise Ln Phone: (404)626-0245 RE#: 172376-0235 Email: Ralph.buck.davis@gmail.com TREE RE OVAL CALCULATIONS REMO ED Legacy(non-oak) Legacy(oak) Oaks Palms Others Total Protected Tre-. Removed: 0 60 15 10 14 99 Mitigat on Needed: 0 30 7.5 5 7 49.5 Tre•, Removed: 10"Palm, 14"Pine,31"Oak, 15"Oak,29"Oak MITIGA ION Legacy(non-oak) Legacy(oak) Oaks Palms Others Total Credit for Tree• Preserved: 0 0 4 0 0 4 Credit for Tre-•Relocated: 0 0 0 0 0 0 Credit for Tr;es Planted: 0 16 0 24 0 40 Total: 0 16 4 24 0 44 Trees Preserved: 4"Oak Trees Relocated: None. Tr-•s Planted:: 2-4"Oaks,2-12"Palms.* *Planted Legacy Tree species receive DOUBLE credit when replacing non-Legacy Trees. The Legacy Tree list includes Bald Cypress; Southern and Eastern Red Cedars; Winged and Florida Elms; Live and Sand Live Oaks; Hickory; Pecan; Pignut Hickory; I oblolly Bay;Southern and Sweetbay Magnolias;Red and Florida Maples;and Tupelo. ADDITIO AL MITIGATION REQUIRED (Mitigation Needed—Total) Legacy(non-oak) Legacy(oak) Oaks Palms Others Total New Tr,- Planted: 0 5.5 0 0 0 5.5 or Payment Into I ree Fund: $0.00 $676.50 $0.00 $0.00 $0.00 $676.50 or A Combination o the Above Additional Notes: Mitigation is 1 inch preserved or planted for every 2 inches removed. Tree Fund rate is $123.00 per inch. Also preserving 30"O. 9"Palm,7"Oak,27"Oak,40"Oak. 7?2 Status is in accorda ce •ith the City of Atlantic Beach code of ordinances in effect at the time of application submittal. / APPROVED La (/ DENIED ❑ 9:41)2/-- Jeremy Htgbsch,TPO ADMINISTRATOR \ DATE , FILE COPY ATLANTIC BEACH SJ 7.5 PERMIT RECEIPT PERMIT DESCRIPTION: LOT CLEARING SITE DEV PERMIT NUMBER: 16-SITE-20 PAID ADDRESS: 720 PARADISE LN MAY 042016 OWNER: WHW INVESTMENT MANAGEMENT LLC CITY OF ATLANT ,BFACH DATE ISSUED: FEES DUE: SITE CLEARING $100.00 Totals: $100.00 1 1 FP:Phi m 0 4 ' ._ _ ,o, s14 5., ' a 2.., .1—I ?&' 4 z-3----. .1gR:1,Tegt4.--g.,,Isn,2- .A.-p. t zn:- g ii.i- °asp l- a as mas`s�-- g 9t � _ son $Isg $.- e- g°s' g fizg- 'a0 S, *1h 4 A Lam= 5ra Q aak g kIIH1Ub 4 I3'=a ! 41 .A' r��� FP z�1". ; _ "�� 6R j gogg� ,_ ° g .iaaB1 iso aSs1;F � ,goga 'g 3 9 '1 IA s3•,o Y; ja a .;35 3,,00aao 1,1 c¢n �{ ,, Sq�B 3$3 Sg a glavg•.QQgn�}$03Rf. m* 31.g4 Si3"E 3 R , 3e', X 8 3toj'�° 3~ CA yg . ' I ggp 8s s Rs a �m �o ° �: Asa Se '" I j t:1 �/- \\\ \4-.,C.tl $ os6 ne•- g.°SRszgBe S ..< a 8s ...J 1 & Q - :V 12 n 4o2 SSR gi" jo :!1 inu °°v FM 0 �:-Z A Kik X1 g A I ,00'ZOl 3„6Z,lc.ZlN m co I ,VO iit.t) ` ,OZ =„t :31VOS �$ t Cl.:1-- ..,CC m 3 li rn ti O I ii-,1,, � I / oI ~ 1 Z (Et W 3.3 vWi � � ~ V I lej:2n W •O _a > WI-N\ EE O ! p N^ wNrno = N.t �+_I Z I m N tr.a �i 1 b O y �\ N Z L Li /� \: ` X�4�.1 \F E �� Qet 1,00'01 3 6 it ZlN 2 ti,, �.vit �! �� co 6 o (I � 1 IN _ w Q 00 I ' m s.7 s.1. s.f. s.f. s_f. �:_.. I �� ro coo oI )i= ��►I' -.:e---,, ,..reimp_____, ( \ �� co b ��_ _ l - in 1 I U . ..\\:. 7,.''t `. =.;:r r .. At: 1 .' M ‘*i ' % 7 ‘ 4.ci: . . . '4 a xA a ,_ s �.s s _ .— is —3's 3'S ,V0 � 17,1 &rob g. �\V_.U_ J;I ,.7 G1 d io a•T 5) A • j N mm D nH CD a m m�o ?No 9m 0 C 7 0 RIOZ PZI rn Z �•W DD pv O r Cb 0 LL— _____il Map Output Page 1 of 1 JAXGIS Property Information \\)..... .__ n. sa' no : [ i ....___._.L.„.._._._._ij >,r .. • ODPOT ar t.• MODwFLOOD FYLAD -. .w / /l •' ?9` =, no no $723no .s i .. { no I >'« gs.. -L.— —a ..-- n w. •a t(4;) . 0I Inen � ie ~ :the ' All HH ' RED Varna Address Tpl"a<tlor AcreaBooloPege Pa Legal Doscnptions Flood Zone AsASit('1EDC E'''''''''' NoCPAC 9u,voi so," Zone Zone Zone Zonlone Roo Nayport 720 67-31 18.25-29E 13 Not in Not$n N/A l loraonta 17237602356PRJCFELD BUILDERS LLAMRANDTISICE BLEACF �W 013 171aa00t67'9418 PARADISE PRESERVE72 PCT ANNUAL CHANCE FLOOD IAZJRDAsnSae EnterDnse ZONEAPlanningr A NA VA 3ultace NA LOT 38 Zone Zone8Iev 32233 Dist: _300'1 • http://gismaps.coj.net/WEBSITE/DuvalMapsSQL/toolbar.asp 8/11/2016 F'!7 COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PARADISE PRESERVE LOT 38 Builder Name: Marco Heating&Air Inc Street: 720 PARADISE LANE Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH,FL, 32233 Permit Number: Owner: SPRINGFIELD BUILDERS.LLC Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2750.5 sqft.) Insulation Area Single familyor multiple familySingle-familya.Frame-Wood,Exterior R=15.0 1328.00 ft2 2. Sin g p b.Frame-Wood,Exterior R=19.0 1260.00 ft2 3. Number of units, if multiple family 1 c.Frame-Wood,Adjacent R=15.0 162.50 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types (1626.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1438.00 ft2 6. Conditioned floor area above grade(ft2) 2759 b. Under Attic(Vented) R=19.0 132.00 ft2 c.other(see details) R= 56.00 ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(418.7 sqft.) Description Area a. Sup:Attic, Ret:Attic,AH:Attic 8 305 a. U-Factor: Tpl,U=0.33 346.67 ft2 b.Sup: Attic, Ret:Attic,AH:Attic 8 247 SHGC: SHGC=0.22 b. U-Factor: Tpl, U=0.55 72.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a.Central Unit 22.2 SEER:14.50 b.Central Unit 17.8 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 22.2 HSPF:8.20 SHGC: b. Electric Heat Pump 17.8 HSPF:8.20 Area Weighted Average Overhang Depth: 4.250 ft. Area Weighted Average SHGC: 0.225 14.Hot water systems a. Electric Cap:50 gallons 8. Floor Types (2759.0 sqft.) Insulation Area EF:0.999 a.Slab-On-Grade Edge Insulation R=0.0 1235.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1188.00 ft2 None c.other(see details) R= 336.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 63.76 PASS Glass/Floor Area: 0.152 Total Baseline Loads: 67.90 I hereby certify that the plans and specifications covered by Review of the plans and .0'IxE SrT�•.,.. this calculation are in compliance with the Florida Energy specifications covered by this •• V. n f4-..0.4,'.. a.,.CN= d°,oy .C.US,OU=, coHeengBtir.Inc•.0- calculation indicates compliance fvj� '11( q uoroth Deane R Heating 8%.tnc..E.COIe�,mm Y,..:3:. Ream t,n�tia«d with the Florida Energy Code. '.,; s,.0 Coupon. i rbc• PREPARED Y: UMW 2016-07-28t?]BAB Before construction is completed a 1'i. - s .. !�r' e DATE: ,/ _. this building will be inspected for 0l, _o, :a c compliance with Section 553.908 .'.• ;. '1r * I hereby certify that this ildin , .-4 -gned, is i compliance Florida Statutes. '� with the Florida Energy/ e. Op OWNER/AGE �- BUILDING OFFICIAL: l DATE: / �(� DATE: ?"11'!C-' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 7/28/2016 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: PARADISE PRESERVE LOT Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2759 Lot# Owner: SPRINGFIELD BUILDERS.L Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Marco Heating&Air Inc Rotate Angle: 135 Street: 720 PARADISE LANE Permit Office: DUVAL CNTY Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH, Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 DOWN 1235 12350 2 UP 1524 12192 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MAIN 1235 12350 Yes 0 1 Yes Yes Yes 2 BEDS 1524 12192 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MAIN 126 ft 0 1235 ft2 ____ 0.2 0.2 0.6 2 Floor over Garage BEDS ____ ___ 316 ft2 19 0.2 0.2 0.6 3 Raised Floor BEDS ____ ___ 20 ft2 19 0.2 0.2 0.6 4 Floor Over Other Space BEDS ____ ___ 1188 ft2 0 0.2 0.2 0.6 ROOF VRoof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1756 ft2 0 ft2 Medium 0.9 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1570 ft2 N N 7/28/2016 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MAIN 19 Blown 46 ft2 0.1 Wood 2 Under Attic(Vented) BEDS 38 Blown 1438 ft2 0.1 Wood 3 Under Attic(Vented) BEDS 19 Blown 86 ft2 0.11 Wood 4 Knee Wall(Vented) BEDS 19 Blown 56 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V it Omt To Wall Type Space R-Value Ft In Ft In Area R-Value Fraction Ahsnr Grada"/ 1 N=>SE Exterior Frame-Wood MAIN 19 39 0 10 0 390.0 ft2 0 0.23 0.4 0 _ 2 E=>SW Exterior Frame-Wood MAIN 19 42 0 10 0 420.0 ft2 0 0.23 0.4 0 _ 3 S=>NW Exterior Frame-Wood MAIN 19 19 0 10 0 190.0 ft2 0 0.23 0.4 0 _4 W=>NE Exterior Frame-Wood MAIN 19 26 0 10 0 260.0 ft2 0 0.23 0.4 0 _ 5 N=>SE Exterior Frame-Wood BEDS 15 39 0 8 0 312.0 ft2 0 0.23 0.4 0 _ 6 E=>SW Exterior Frame-Wood BEDS 15 44 0 8 0 352.0 ft2 0 0.23 0.4 0 _ 7 S=>NW Exterior Frame-Wood BEDS 15 39 0 8 0 312.0 ft2 0 0.23 0.4 0 _8 W=>NE Exterior Frame-Wood BEDS 15 44 0 8 0 352.0 ft2 0 0.23 0.4 0 9 S=>NW Garage Frame-Wood BEDS 15 16 3 10 0 162.5 ft2 0.23 0.01 0 DOORS V # Omt Door Type Space Storms U-ValueWidth Height Area Ft In Ft In 1 S=>NW Insulated MAIN None .35 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 135 degrees). / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SE 1 Vinyl Low-E Triple Yes 0.33 0.22 12.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5 2 N=>SE 1 Vinyl Low-E Triple Yes 0.55 0.25 72.0 ft2 4 ft 0 in 2 ft 0 in None Exterior 5 3 N=>SE 1 Vinyl Low-E Triple Yes 0.33 0.22 48.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5 4 E=>SW 2 Vinyl Low-E Triple Yes 0.33 0.22 12.0 ft2 2 ft 0 in 12 ft 0 in None Exterior 5 5 E=>SW 2 Vinyl Low-E Triple Yes 0.33 0.22 36.0 ft2 2 ft 0 in 12 ft 0 in None Exterior 5 6 S=>NW 3 Vinyl Low-E Triple Yes 0.33 0.22 36.0 ft2 7 ft 6 in 2 ft 0 in None Exterior 5 7 W=>NE 4 Vinyl Low-E Triple Yes 0.33 0.22 6.0 ft2 2 ft 0 in 12 ft 0 in None Exterior 5 8 N=>SE 5 Vinyl Low-E Triple Yes 0.33 0.22 6.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 9 N=>SE 5 Vinyl Low-E Triple Yes 0.33 0.22 16.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 10 N=>SE 5 Vinyl Low-E Triple Yes 0.33 0.22 45.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 11 E=>SW 6 Vinyl Low-E Triple Yes 0.33 0.22 11.7 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 12 E=>SW 6 Vinyl Low-E Triple Yes 0.33 0.22 30.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 13 S=>NW 7 Vinyl Low-E Triple Yes 0.33 0.22 16.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 14 S=>NW 7 Vinyl Low-E Triple Yes 0.33 0.22 60.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 15 W=>NE 8 Vinyl Low-E Triple Yes 0.33 0.22 12.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 7/28/2016 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 408 ft2 384 ft2 46 ft 10 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000283 2045.2 112.28 211.15 .2679 5 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 22.2 kBtu/hr 2 sys#1 2 Electric Heat Pump Split HSPF:8.2 17.8 kBtu/hr 1 sys#2 COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14.5 22.2 kBtu/hr cfm 0.7 2 sys#1 2 Central Unit Split SEER: 14 17.8 kBtu/hr cfm 0.7 1 sys#2 HOT WATER SYSTEM ✓ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.999 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply-- —Retum— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 8 305 ft2 Attic 76 ft2 Default Leakage Attic (Default) (Default) 1 1 2 Attic 8 247 ft2 Attic 62 ft2 Default Leakage Attic (Default) (Default) 2 2 7/28/2016 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan FebMar , Apr May Jun ;X;Jul Aug Sep Oct Nov Dec Heating X Jan X Feb Mar Apr May ri Jun Jul Aug ri Sep ' Oct Nov X Dec Venting Jan Feb pq Mar X Apr May Jun ' ' Jul Aug Sep X Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 80 78 80 78 78 78 78 78 78 78 0 78 800 80 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 68 66 66 66 68 68 68 68 68 68 68 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 0 Ill 7/28/2016 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index,the more efficient the home. 720 PARADISE LANE, ATLANTIC BEACH, FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=15.0 1328.00 ft2 b.Frame-Wood,Exterior R=19.0 1260.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=15.0 162.50 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1438.00 ft2 6. Conditioned floor area(ft2) 2759 b.Under Attic(Vented) R=19.0 132.00 ft2 7. Windows** Description Area c.other(see details) R= 56.00 ft2 a. U-Factor: Tpl,U=0.33 346.67 ft2 11.Ducts R ft2 P a.Sup:Attic,Ret:Attic,AH:Attic 8 305 SHGC: SHGC=0.22 b.Sup: Attic,Ret:Attic,All:Attic 8 247 b. U-Factor: Tpl,U=0.55 72.00 ft2 SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 22.2 SEER:14.50 SHGC: b.Central Unit 17.8 SEER:14.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 22.2 HSPF:8.20 Area Weighted Average Overhang Depth: 4.250 ft. b.Electric Heat Pump 17.8 HSPF:8.20 Area Weighted Average SHGC: 0.225 8. Floor Types Insulation Area 14. Hot water systems Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1235.00 ft2 a.Electric EF: 1 b.Floor Over Other Space R=0.0 1188.00 ft2 c.other(see details) R= 336.00 ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ;:....ESp9'• tin through the -•ove energysavingfeatures which will be installed (or exceeded) ff. _ TF' •.: Construe o g y�. p in this home before fin- ins,ection. Oth- I : PL Display Card will be completed .:yQi , `:. i based on installed Co r e co pli t feat,res. 0 Imo ''• _ o '4 a c..�:e B p4 .' , , -..- p Builder Signature: Date: P-/--/ G .0 ; e__ 'a Address of New Home:7Zr) ��K s, LU�, City/FL Zip: /,,L Rj Fl ••• C... . 7.1 ....`"SS Opw>r . -3-1-E1. *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/28/2016 1:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number Jacksonville,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. / R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar matenals shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verity compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the lest,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be fumed off;and 6.Supply and retum registers,if installed at the time of the test,shall be fully open. / R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitling flue dampers and outdoor combustion air. 0/ R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm • per square foot(1.5 Us/m2),and swinging doors no more Than 0.5 cfm per square foot(2.6 Us/m2),when tested according 10 NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. / R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be seated to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psi(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate healing and cooling system. 4. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed al the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 0 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 7/21/2015 11:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS- (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the /' design air flow rate when tested in accordance with ASHRAE 193. (7 R403.2.3 Building Cavities(Mandatory).Building framing cavities shall not be used as ducts or plenums. ,yf R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41`C) or below 55°F(13°C)shall be insulated to a minimum of R-3., 0 R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. yr R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. 11403.4.3 Heat traps(Mandatory). Storage water healers not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'h inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. j/j R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies -- R403.4.4.1 Storage water heater temperature controls r • 11403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. R403.4.4.2 Water heating equipment. Water healing equipment Installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal:and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table 1403.5.1. Exception:Where mechanical ventilation tans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. / R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or 11-19,space permitting,or R-10 otherwise. 7{ 14403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. Jo/ 11403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section 11302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • 14403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 7/21/2015 11:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 II FORM R405-2014 MANDATORY REQUIREMENTS- (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower ctm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains it the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. / R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heal pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6,1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • 11403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ 11403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting otf the system when the pavement temperature is above 55`F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. in 11403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. o R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-oft switch that is mounted outside the heater to allow shutting oft the healer without adjusting the thermostat setting. 11403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verity procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. o R403.9.2 lime switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: ▪ I. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. o 11403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or / • solar energy source computed over an operating season. 1)? 1111404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanency installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights R405.2performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of 11-6. /o R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 7/21/2015 11:18 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PARADISE PRESERVE LOT 38 Builder Name: Marco Heating&Air Inc Street: 720 PARADISE LANE Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number: Owner: SPRINGFIELD BUILDERS.LLC Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or r` unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 7/28/2016 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: PARADISE PRESERVE LOT 38 Builder Name: Marco Heating&Air Inc Street: 720 PARADISE LANE Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 2759 sq.ft. Cond.Volume: 24542 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE I FLOW: I ELA: Eq LA: ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off;and 6.Supply and retum registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, .O�•�tiE performance results demonstrate compliance testing shall be conducted by an 9.e• with Florida Energy Code requirements in approved third party.A written " accordance with Section R402.4.1.2. report of the results of the test shall ' `�` """ :;i • •O ` be signed by the third party I og -�- a conducting the test and provided to . SIGNATURE: the code official. D wE PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 7/28/2016 1:07 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: PARADISE PRESERVE LO... wri htsoft Date: JULY 28,2016 9 Entire House By: MARCO HEATING&AIR Plan: 2759 SQ FT Marco Heating &Air Inc 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 38, SPRINGFIELD BUILDERS. LLC 720 PARADISE LANE,ATLANTIC BEACH, FL 32233 Desi•n Conditions Location: Indoor: Heating Cooling Jacksonville Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 33 ft Design TD(°F) 38 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 11.0 51.2 Dry bulb(°F) 33 93 Infiltration: Daily range(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ft2 Btuh %of load Walls 3.0 7317 22.1 Glazing 12.4 5181 15.7 Doors 14.6 294 0.9 Ceilings 1.0 1531 4.6 Floors 3.5 6485 19.6 Infiltration 1.9 5204 15.7 Ducts 7047 21.3 °� lliTh*mkn Piping 0 0 Humidification 0 0 Ventilation 0 0 °"" Adjustments 0 Total 33059 100.0 Coolin• Component Btuh/ft2 Btuh %of load , Walls 1.8 4311 14.0 w "'B"a'Ga`"5 Glazing 20.2 8450 27.4 Doors 11.8 237 0.8 Ceilings 1.4 2192 7.1 Floors 0.1 95 0.3 Infiltration 0.5 1316 4.3 Ducts 9720 31.5 Gam, Ventilation 0 0 Ducts Internal gains 4550 14.7 Blower 0 0 Adjustments 0Othe , Total 30870 100.0 Ce.fin9s Infiltrafion Latent Cooling Load=9632 Btuh Overall U-value=0.089 Btuh/ft2-°F Data entries checked. �y. 2016-Jul-28 13:30:40 •r Wright�SOft- Right-Suite®Universal 2017 17.0.01 RSU17889 Page 1 AM ..38 720 PARADISE tANE\BUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW • 4 wrightsoft Right-J® Worksheet Job: PARADISE PRESERVE LOT 38 Entire House Date: JULY 28,2016 By: MARCO HEATING&AIR Marco Heating &Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 1 Room name Entire House UP 2 Exposed wall 308.0 ft 182.0 ft 3 Room height 8.8 ft 8.0 ft 4 Room dimensions 5 Room area 3075.0 ft' 1840.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') ' Load I number r(Btuh/ft'-°Fr ( (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh) IHeat I Cool I Gross I N/P/S I Heat I Cool I Gross I N/P/S Heat I Cool 1 6 W 12D-Osw 0.086 ne 3.23 2.00 312 236 761 471 312 236 761 471 -G 1F-c3ov 0.330 ne 12.38 18.48 16 0 198 296 16 0 198 296 -0 1F-c3ov 0.330 ne 12.38 18.48 60 0 743 1109 60 0 743 1109 w 12E-Osw 0.068 ne 2.55 1.43 190 134 341 192 0 0 0 0 11 -G 1F-c3ov 0.330 ne 12.38 18.48 36 0 446 665 0 0 0 0 f p 11D0 0.390 ne 14.62 11.78 20 20 294 237 0 0 0 0 W 12B-Osw 0.097 se 3.64 2.70 128 128 466 345 128 128 466 345 W 12D-0sw 0.086 se 3.23 2.00 352 340 1097 678 352 340 1097 678 I� 1F-c3ov 0.330 se 12.38 13.07 12 8 149 157 12 8 149 157 W 12E-Osw 0.068 se 2.55 1.43 260 254 648 364 0 0 0 0 �G 1F-c3ov 0.330 se 12.38 19.39 6 0 74 116 0 0 0 0 W 12D-Osw 0.086 sw 3.23 2.00 312 245 790 489 312 245 790 489 -G 1F-c3ov 0.330 sw 12.38 13.07 6 4 74 78 6 4 74 78 -G 1F-c3ov 0.330 sw 12.38 16.23 16 5 198 260 16 5 198 260 -G 1F-c3ov 0.330 sw 12.38 16.86 45 11 557 759 45 11 557 759 W 12E-Osw 0.068 sw 2.55 1.43 390 258 658 370 0 0 0 0 -G 1F-c3ov 0.330 sw 12.38 9.36 12 12 149 112 0 0 0 0 -G 1F-c3ov 0.330 sw 12.38 11.84 72 54 891 852 0 0 0 0 -G 1F-c3ovd 0.330 sw 12.38 9.36 48 48 594 449 0 0 0 0 V/ 12D-Osw 0.086 nw 3.23 2.00 352 310 1001 619 352 310 1001 619 -1, 1F-c3ov 0.330 nw 12.38 18.48 12 0 144 216 12 0 144 216 -G 1F-c3ov 0.330 nw 12.38 18.48 30 0 371 554 30 0 371 554 V/ 12E-Osw 0.068 nw 2.55 1.43 420 372 949 534 0 0 0 0 -G 1F-c3ov 0.330 nw 12.38 18.48 12 0 149 222 0 0 0 0 -G 1F-c3ov 0.330 nw 12.38 18.48 36 0 446 665 0 0 0 0 P 12C-Osw 0.091 - 3.41 1.39 178 178 607 248 168 168 573 234 C 165-38ad 0.026 - 0.98 1.40 1570 1570 1531 2192 1524 1524 1486 2128 F 19C-19cscp 0.049 - 0.64 0.30 316 316 201 95 316 316 201 95 F 22A-tpm 1.180 - 44.25 0.00 1551 142 6283 0 316 16 708 0 6 I c)AED excursion 1939 352 Envelope loss/gain I ( 20808 15285 I 95161 8839 12 a) Infiltration 5204 1316 2790 705 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 5 1150 4 920 Appliances/other 3400 1000 Subtotal(lines 6 to 13) 26012 21151 12306 11465, Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26012 21151 12306 11465 15 Duct loads 27% 46% 7047 9720 33% 50% 4107 5705 I I TAiortal required be( d ) I I I 313331 303331 I I 167401 17740 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AC 414- Wrightsof t Page 1 2016-Jul-28 13:30:40 Right-Suite® 2017 17.0.01 RSU17889 ..38 720 PARADISE LANE\BUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW -+#+- wrightsoft Right-J® Worksheet Job: PARADISE PRESERVE LOT 38 Entire House Date: JULY 28,2016 By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 1 Room name DOWN 2 Exposed wall 126.0 ft 3 Room height 10.0 ft 4 Room dimensions 5 Room area 1235.0 f t' i I I I Ty Construction U-value OrHTM Area (ft') Load Area Load number (Bt uh/ft'-'F I (Bt uh/ft') I or perimeter (ft) 1 (Bluh) or perimeter Ir 1 Heat I Cool I Gross I N/P/S I Heat Cool I Gross I N/P/S Heat I Cool I I f 1 6 V/ 12D-Osw 0.086 ne 3.23 2.00 0 0 0 0 -G 1F-c3ov 0.330 ne 12.38 18.48 0 0 0 0 -G 1F-c3ov 0.330 ne 12.38 18.48 0 0 0 0 W 12E-Osw 0.068 ne 2.55 1.43 190 134 341 192 11 I-G 1F-c3ov 0.330 ne 12.38 18.48 36 0 446 665 II D 1100 0.390 ne 14.62 11.78 20 20 294 237 W 12B-0sw 0.097 se 3.64 2.70 0 0 0 0 VII 12D-Osw 0.086 se 3.23 2.00 0 0 0 0 t G 1F-c3ov 0.330 se 12.38 13.07 0 0 0 0 V/ 12E-Osw 0.068 se 2.55 1.43 260 254 648 364 I� 1F-c3ov 0.330 se 12.38 19.39 6 0 74 116 V/ 12D-Osw 0.086 sw 3.23 2.00 0 0 0 0 G- 1F-c3ov 0.330 sw 12.38 13.07 0 0 0 0 -G 1F-c3ov 0.330 sw 12.38 16.23 0 0 0 0 -G 1F-c3ov 0.330 sw 12.38 16.86 0 0 0 0 V/ 12E-Osw 0.068 sw 2.55 1.43 390 258 658 370 -G 1F-c3ov 0.330 sw 12.38 9.36 12 12 149 112 G 1F-c3ov 0.330 sw 12.38 11.84 72 54 891 852 -G 1F-c3ovd 0.330 sw 12.38 9.36 48 48 594 449 V/ 120-0sw 0.086 nw 3.23 2.00 0 0 0 0 -G 1F-c3ov 0.330 nw 12.38 18.48 0 0 0 0 -G 1F-c3ov 0.330 nw 12.38 18.48 0 0 0 0 V/ 12E-Osw 0.068 nw 2.55 1.43 420 372 949 534 -G 1F-c3ov 0.330 nw 12.38 18.48 12 0 149 222 -C 1F-c3ov 0.330 nw 12.38 18.48 36 0 446 665 P 12C-Osw 0.091 - 3.41 1.39 10 10 34 14 C 16B-38ad 0.026 - 0.98 1.40 46 46 45 64 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 F 22A-tpm 1.180 - 44.25 0.00 1235 126 5575 0 61 c)AED excursion 1587 Envelope loss/gain 11291 6445 If Ir 12 a) Infiltration 2414 610 b) Room ventilation 0 0 13 Internal gains: Occupants @ 2301 230 Appliances/other 2400 Subtotal(lines 6 to 13) 13706 9686 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 13706 9686 15 Duct loads 21% 41% 2941 4015 1 Air Totalrequirroom load I I l 1 16 931 1359031 I 1 1 1 I ed l Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft2016-Jul-2813:30:40 Right-Suite®U niversal 2017 17.0.01 RSU17889Ar Page 2 'C-h ..38 720 PARADISE LANE 1BUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW - Project SummaryJob: PARADISE PRESERVE LO... +- wrightsoftDate: JULY 28,2016 Entire House By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 38, SPRINGFIELD BUILDERS. LLC 720 PARADISE LANE, ATLANTIC BEACH, FL 32233 Notes: ORIENTATION- NORTHWEST-FRONT DOOR Desi• n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 Moisture difference 51 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26012 Btuh Structure 21151 Btuh Ducts 7047 Btuh Ducts 9720 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33059 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 30870 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 7351 Btuh Ducts 2281 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 3075 3075 Equipment latent load 9632 Btuh Volume Cr) 27068 27068 Air changes/hour 0.28 0.15 Equipment total load 40503 Btuh Equiv. AVF (cfm) 126 68 Req.total capacity at 0.70 SHR 3.7 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a • Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4 wrightsoft2018-Jul-28 13 29:e8 Q Right-Suite®Universal 2017 17.0.01 RSU17889 Page 1 ACCk ...38 720 PARADISE LANEIBUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW Project Summa Job: PARADISE PRESERVE LO... wrightsoft Date: JULY 28,2016 DOWN By: MARCO HEATING 8 AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 38, SPRINGFIELD BUILDERS. LLC 720 PARADISE LANE, ATLANTIC BEACH, FL 32233 Notes: ORIENTATION-NORTHWEST-FRONT DOOR Desi• n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 To Moisture difference 51 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13706 Btuh Structure 9686 Btuh Ducts 2941 Btuh Ducts 4015 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16646 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 13700 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3791 Btuh Ducts 930 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1235 1235 Equipment latent load 4721 Btuh Volume(ft') 12348 12348 Air changes/hour 0.28 0.15 Equipment total load 18422 Btuh Equiv. AVF (cfm) 59 31 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB018****A Cond CH14NB018****A AHRI ref 7845770 Coil FB4CNP018L AHRI ref 7845770 Efficiency 8.2 HSPF Efficiency 11.7 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17600 Btuh @ 47°F Latent cooling 5340 Btuh Temperature rise 27 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri ht ft 2016-Jul-281329:56 9 Right-Suite® Universal 2017 17.0.01 RSU17889 pace 2 ...38 720 PARADISE LANE\BUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW Job: PARADISE PRESERVE LO... +I+ wrightsoft Project Summary Date: JULY 28,2016 UP By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd.Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 38, SPRINGFIELD BUILDERS. LLC 720 PARADISE LANE, ATLANTIC BEACH. FL 32233 Notes: ORIENTATION- NORTHWEST-FRONT DOOR Desi• n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 Moisture difference 51 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 12306 Btuh Structure 11465 Btuh Ducts 4107 Btuh Ducts 5705 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16413 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17170 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3560 Btuh Ducts 1351 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1840 1840 Equipment latent load 4911 Btuh Volume (ft3) 14720 14720 Air changes/hour 0.28 0.15 Equipment total load 22081 Btuh Equiv.AVF (cfm) 68 36 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB024****A Cond CH14NB024****A AHRI ref 8282582 Coil FB4CNP025L AHRI ref 8282582 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14.5 SEER Heating input Sensible cooling 15540 Btuh Heating output 22200 Btuh @ 47°F Latent cooling 6660 Btuh Temperature rise 27 °F Total cooling 22200 Btuh Actual air flow 740 cfm Actual air flow 740 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Jul-2813:29:e8 Twrightsoft Right-Suites® RSU17889 Page 3 ..38 720 PARADISE LANE\BUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW Manual S Com liance Report Job: PARADISE PRESERVE LO... - wrightSOft PDate: JULY 28,2016 DOWN By: MARCO HEATING&AIR Marco Heating &Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Project Information For: PARADISE PRESERVE LOT 38,SPRINGFIELD BUILDERS. LLC 720 PARADISE LANE,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.7°F Sensible gain: 13700 Btuh Entering coil DB: 78.0°F Outdoor design WB: 77.1°F Latent gain: 4721 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 18422 Btuh Indoor RH: 50% Estimated airflow: 593 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB018****A+FB4CNP018L Actual airflow: 593 cfm Sensible capacity: 12460 Btuh 91%of load Latent capacity: 6660 Btuh 141%of load Total capacity: 19120 Btuh 104%of load SHR: 65% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 16646 Btuh Entering coil DB: 68.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB018****A+FB4CNP018L Actual airflow: 593 cfm Output capacity: 17800 Btuh 107%of load Capacity balance: 32 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 593 cfm Output capacity: 5.0 kW 102%of load Temp.rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Jul-28 13:29:56 wrightsoft Right-Suite®U niversal 2017 17.0.01 RSU17889 Page 1 ^�+�^� ...38 720 PARADISE LANEIBUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW • Manual S Compliance Report Job: PARADISE PRESERVE LO... 41. WPightsoft• p p Date: JULY 28,2016 UP By: MARCO HEATING&AIR Plan: 2759 SQ FT Marco Heating &Air Inc 720 Mill Creek Rd,Jacksonville.FL 32211 Phone:904-743-3350 Fax:904-743-4427 License:CAC1815711 Project Information For: PARADISE PRESERVE LOT 38, SPRINGFIELD BUILDERS. LLC 720 PARADISE LANE,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.7°F Sensible gain: 17170 Btuh Entering coil DB: 78.5°F Outdoor design WB: 77.1°F Latent gain: 4911 Btuh Entering coil WB: 64.2°F Indoor design DB: 75.0°F Total gain: 22081 Btuh Indoor RH: 50% Estimated airflow: 740 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB024****A+FB4CNP025L Actual airflow: 740 cfm Sensible capacity: 15540 Btuh 91%of load Latent capacity: 6660 Btuh 136%of load Total capacity: 22200 Btuh 101%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 16413 Btuh Entering coil DB: 68.2°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB024****A+FB4CNP025L Actual airflow: 740 cfm Output capacity: 22200 Btuh 135%of load Capacity balance: 26 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 740 cfm Output capacity: 4.1 kW 86%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Jul-28 13:29:56 wrtghtsoft' Right-Suite®Universal 2017 17.0.01 RSU17889 Paget ACC*, ...38 720 PARADISE LANEIBUCKY DAVIS 2759 SQFT.rup Calc=MJ8 Front Door faces:NW SPRINGFIELD BUILDERS PLAN: CUSTOM 2759 SF LOT#: 38 SUBDIVISION: PARADISE PRESERVE CARRIER 1.5 TON HEAT PUMP SYSTEM SEER: _14 HSPF: _8.2_ CARRIER 2.0 TON HEAT PUMP SYSTEM SEER: 14_ HSPF: 8.2_ DESIGN COOL BTUH: 42000 AVAILABLE STATIC PRESSURE: 1.1_ TOTAL CFM: 1935 TOTAL EFFECTIVE LENGTH: 295_ PERFORMANCE METHOD: DUCT MATERIAL: R6 VINYL FLEX SUPPLY BRANCH DETAIL TABLE ROOM NAME COOLING CFM BRANCH SIZE LINEAR FT DUCT MATERIAL LOFT 165 CFM 7" 10' VINYL FLEX DINING 165 CFM 7" 15' VINYL FLEX LIVING ROOM (2) 200 CFM (2) 8" 40' VINYL FLEX KITCHEN 165 CFM 7" 12' VINYL FLEX BATH 3 35 CFM 4" 19' VINYL FLEX LAUNDRY 35 CFM 4" 22' VINYL FLEX BR 4 165 CFM 7" 12' VINYL FLEX BR 4 WIC 35 CFM 4" 12' VINYL FLEX BATH 4 35 CFM 4" 15' VINYL FLEX BR3 165 CFM 7" 20' VINYL FLEX BATH 2 35 CFM 4" 15' VINYL FLEX BR2 165 CFM 7" 15' VINYL FLEX MBR (2) 100 CFM (6) 6" 32' VINYL FLEX MBA 100 CFM 6" 20' VINYL FLEX MBR WIC 35 CFM 4" 15' VINYL FLEX MBA TOILET 35 CFM 4" 21' VINYL FLEX TOTALS 1935 CFM 295 LN (FT) SUPPLY TRUNK DETAIL TABLE LOCATION DESIGN BTUH TRUNK SIZE DUCT MATERIAL FROM UNIT TO 1ST DISTR BOX 12202 10" VINYL FLEX FROM UNIT TO 1ST DISTR BOX 21054 14" VINYL FLEX 3 NIDE 50 • Mr LL f' 8sow,-AIN —— v N• 1 , I GOVERED PORCH 1 v-cr aG+STEP I ILK OFI 8 FLOOR ABOVE ii 6,34. ',�-�" 8-6' � 3-8Y2. 3'•4' 3'-4' / 3'4' 4'•7y' /( J � 10405M c�-0 0605N 30605M 30605H 30605N t ! E AFF - •y,''•rr 3=' =r '*3i•AFF 96'AFF D.M.G. 1 I 1 D.M.C.I -_ _. as � r I L_._-1. i l t L ii„L_____R AIDMANDLER(5) L DAV �'�` mu II ANO LOC PION KITCHQ4I g1 vxr N ' S O 64y 2-0'-h•z� x 26'•0' /I 4- 4'X5';NANO I I--r! 8A5E CA86 W! vat, O�0*".„, 6 � 44 i a PINING LIVING� R 4 0,0 1 WALL { g i l'''''''... OELON 4 Io -, I gl Wim'X ONG / a ` 3'4' 46/2' 6-1V2' 1 9 2 ' 17 9sT d* . i� 41 '' � NC ) .a84.J,. �' \ . r , , M , , 9e }k I f' =ATH e al ill.ASToRA6E 1 I : �, _ U r 55H 1 I maiiiii ,' WIG tr k'' i 0 74 r 3 5' I OPT LAUNDRY o 1�N,IE , �� TUB D M 1 I • WALL DEMO .. . if 2 CAR GARAGE FOYER 10-0.0.G,51 r '- l -3'CLO t 9 i4BEDROOM r -6_ 1 .•':L OF 2ND FL MNr - I 9� 9A I 3'•3' 3.! i 4'-a 3'-6' 4'4 M r . . --1o/ ENTRY I X3-0"CLG.5TEP I I 12"50 COI _IICAMRFVERED ROOF AD Y _. I I II I 12'MME SO FIT Ade 1 I Merl r Ttr 1-0' k r r 6.6 -e 10'-2' / 9.2' r 8 6' 11'-2 f r r UNE OF PORCH KAY -I 4040 FX 302D FX 096'AFF SH/BAR 096'AFF 305054 308054 30505,• 55+. �� 096*AFF 096"AFF 09V A'' �'�'= UNEN n ! s 111C 4g V2 2R k 9-0'0.6 X 5$x v - \ yy --5'4' 4 X 6'. '—L77 � OPT TRAY 1010'-0' J 4Z TO NOR A&10! T-3Y(' 4Z V2 WALL BE' G M.BATH ...,..,v, (C. 947 CIG I 24,DR ® III.1 u�l • MASTER BEDROOM STApc - '9 f,x'' 'C. ,* 7171r 'i' 10..3, b 44- —.:: 1414 134lr It I L ........ _�- . .... ,, A MI I, I OpyN. 1 .... ,.../2.4 . :ti.' N Ilb.. A tz„..,,tt-0" a �r R am a��gn1�! _/,®/4T4N INC 9r '-.— � .�ix-� -,1� AIM1411M111111121 a -/ 8 12 rm, EnL T $lr142lir 3.6 i 5-6' ��� 5� �fl •Y 1` --- ,tIMMINNE..7 RIS ilk S #- : -- 2tXONOE N \ A. 7 BEDROOM 2 sx ®t.. z ..y t--§ ,...i • 1 m ° 1x-b BEDROOM 3 I ' - m� 9 NC NC�c tt6"xII r MO 514 oar Arc zp f — 0 154'M t CANOLDER 3050 91 II • AFF II -- -el ROOF ADY U__ --ll L– _GARAGE WALL 6EU)A J LANTREVER IT– TIr ROOF ABV II II LL _u CANTILEVER J ROOF AN -- ---- ---- I I L uE of row+mom J vt--4•-4'--s—3'-6'—f 4'4"---. 3•-5'—s' 8-Z s—3'-3' i 4•-4• 3'6' 04' FILE COPY PRODUCT APPROVAL INFORMATION SHEET (PAIS) FOR THE CITY OF JACKSONVILLE (Revised:July 8,2008) Project Name: Future Residence- Lot 38 P E. Gam,_ SF'2 tMeg Project Address 720 Paradise Lane, Atlantic Beach, Fl. 32233 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please p i theirifogrmlat>lonan'dproductir approval number(s)for the building components listed below as applicable to the buildin cori�truction project for the permit: number listed above. You should contact your product supplier if you do not know the p duct approv-drriumber for any oft e applicable listed products. Information regarding statewide product approval may be ob atp//www.floridabuilding. rg. See Bulletins G-25-04 and G-03-05 for more information. Product Description or Product Category/Subcategory Manufacturer Model No. Limits of Use Approval # Local # A. EXTERIOR DOORS 1. Swinging Masnnite FI-43.34 2. Sliding 3. Sectional 4. Roll up CHI Overhead FL-15074 5. Automatic 6. Other: B.WINDOWS 1. Single hung Silverline FL-14911.1 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed Silverline FL-14918.2, 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other: C. PANEL WALL 1. Siding James Hardie FL-13209 2. Soffits .lamps Hardie FL-13265 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other: Printed Date: 7/10/2008 Page 1 of 3 F1L7 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # D. ROOFING PRODUCTS 1. Asphalt shingles Owens Corning Fl -10674: 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other: E. SHUTTERS 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other: F. STRUCTURAL COMPONENTS 1. Wood connector/anchor Simpson FL-2355 2. Truss plates 3. Engineered lumber Ga Pacific F12023.1 4, Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other: Printed Date: 7/10/2008 Page 2 of 3 FILE COPY Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # G. SKYLIGHTS 1. Skylight 2. Other: H. NEW EXTERIOR ENVELOPE PRODUCTS 1 2 In addition to completing the above list of manufacturers, product descriptions and State approval numbers for the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected. they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Contractor/Authorized Agent: Ralph Buck Davis (Print) (Signature) Company Name: Springfield Builders, LLC Mailing Address: 13846 Atlantic Blvd. #204 City: JacksonvilleState: FI' Zip Code 2225 Telephone Number: ( ) Fax Number: ( Cell Phone Number: (404 ) 626-0245 E-mail Address: ralph.buck.davis@gmail.com Printed Date: 7/10/2008 Page 3 of 3