Loading...
1764 MARITIME OAK DR - PERMIT r,,,J\V,/., '- CITY OF ATLANTIC BEACH f r' c1 800 SEMINOLE ROAD J , ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 0J2I9r SINGLE FAMILY DWELLING NEW MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFR-1093 Job Type: SINGLE FAMILY RESIDENCE Description: NEW SINGLE FAMILY RESIDENCE Estimated Value: $320,857.00 Issue Date: 6/16/2016 Expiration Date: 12/13/2016 PROPERTY ADDRESS: Address: 1764 MARITIME OAK DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: TOLL BROS.,INC Address: 250 GIBRALTAR RD STEVEN R MERTEN Phone: - - PERMIT INFORMATION: FEES:-- -- ---- -- --- - ---- ----- ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $571.29 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $1,142.57 STATE DCA SURCHARGE $17.14 SEWER SDC-SYSTEM DEV CHG $4,050.00 STATE DBPR SURCHARGE $17.14 ``//��,,pp��- pp r����� T p Q -7- p Q n IINAPI &`KhY'1t' 4,c `a,V3`N,.MgTiggN(.1. 1 11•QQ.1. ('11'% OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. - I "ll- �' \s CITY OF ATLANTIC BEACH ifr------._. 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 WATER CROSS CONNECTION $50.00 WATER SDC-SYSTEM DEV CHG $1,140.00 Total Payments: $7,508.14 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. cam _ 1 ` .h MAY1 6 2016 CITY OF ATLANTIC BEACH tt� 800 Seminole Road •wt: _ ' �' Atlantic Beach,Florida 32233 Telephone(904)247-5800 FAX(904)247-5845 REVISION REQUEST SHEET Date: 5 13 I I (v Received by: Resubmitted: Permit Number: tt -S F12—1 093 Original Plans Examiner: , Project Name: Project Address: 1 -76q-- NrAgi`�t M e CM-K. Contractor: Tot grOt'hOrs Inc, Contact Name: Ash Contact Phone :004)b95 6243 Contact e-mail: CtroBOrg (�1-nub ,YS C0 r11 Revision/Plan Check/Permit Fee(s)Due: $ Description of Proposed Revision to Existing Permit: New picuelpit -! t rivPLU t I i d` yi_. ,Si det,lJ 1 K Additional Increase in Building $Value: Ni J k � Additional S.F. Site Plan Revised: Public W/U Approval: By signing below.I(print name) Re j RO9 c affirm that the above revision is inclusive of the pr;gg sed changes. "1 Signature oontractor/Agent it — r - -�� g tust sign if increase in valuation) nate Office Use Only_._.--_---- LCCLOMC � Date: Approved: Rejected:----- i 1 I by: MAY 1 6 2016 Plan Review Connnents: De a artment review required Yes No ` :uildi a !r tinning &Zonin. Tree AdministratorPlans Examiner —w I �'fic Works `u.lic Safety Fire Services Date Created WWI,Rev.2 r ? C es i iiy'4. �, • 4 ,, MAy 1 6 • CI'T'Y OF ATLANTIC BEACH P.. + , tsl .r;�, 6 800 Seminole Road J Atlantic Beach, Florida 32233 !3' j Telephone(904)247-5800 FAX(904)247-5845 I REVISION REQUEST SHEET Date: S I l3 11 (•p Received by: Resubmitted: Permit Number: %ty -SFt2._1 3 Original Plans Examiner: - Project Name: Project Address: 1 76,21---MARI-I-t h e. d,,} t r Contractor: T -So it erotnc in G Contact Na R __ Contact Phone :924)6(315 624Q (a? 5 3 Contact e-mail: , `S Revision I Plan Check/Permit Fee(s)Due: $ tattbnbtXS COIr✓) Description of Proposed Revision to Existing Permit: Nieu.) i-c, •t o i •e l .- ' _Glave-w___...- i1 id`�'V► _ S(ckeUJ l K .__ a' " . t • 't/' .�-____..______ ____ Additional Increase in Building Value: $ 6) Additional S.F. N I k I Site Plan Revised: Public W/U Approval: By signing below. I(print name) /h`.pa a Ro(,� is inclusive of the pr. . sed changes. "`1 J- �_-_-----• a arm that the above revision ( (3_01.s Signature o antractor/Agent( 1.o Mir list sign if increase in valuation) Date r� Office Use Only ------ c E o M E Date: Approved: • Rejected:_ i sed b MyAY 1 6 2016 Plan Review Comments: J _ La r '7 Dejartment review required Yes No uiidi arming&ZoningiC__Ael_i__ ---- -,-- Tree Administrator v' Plans E. miner 'n:11 . . T a is Utititie _—' 51((7 (G •ub1ic Safety Fire Services Date frilled i/XVIS Rev.2 i_l c J MA Vin, CI•I'Y nh ATLANTIC BE s -�' � BEACH `�• _ - ►i� ''; 800 Seminole Road j Atlantic Beach, Florida 32233 J 4� ti Telephone(904)247-5800 FAX(904)247-5845 REVISION REQ(JES•r SHEET Date: 5 113 1 I ID Received by: Resubmitted: ►� -s1=C2 -1Qq3 - --- Permit Number: Original Plans Examiner: - Project Name: Project Address: 17Cv4- N1. - - - - -.. Contractor: To It r Ag tT t ne. © -tc.--t om— _-_.___.-_— 6 otletc I rl C — Contact Name: -ASViLe ( RD __ Contact Phone :(g04 E__ 5 SZ43 Contact e-mail: qro %- ���-'`4�- _-- Revision/Plan Check/Permit Fee(s)Due: $ v'" �I(�r ' 1 tcXS •C.O1'V) Description of Proposed Revision to Existing Permit: NQw-�•►t ' �10,-ri R, I c�.'.-"wxa- t ..J- -�r_l1L�J 1ti1 ctil!1_. Si deI,tiGL I K Additional Increase in Building Value: $ 0 Additional S.F. NJ I k Site Plan Revised: Public W/U Approval: By signing below. I(print name) Q •.• Jg - . ����nn that the above revision is inclusive of the pr sed changes. Signature o ontractor/Agent 0 In list sign ifincreuse in valuniion) Date ,-- / Office Use Only nn M(�— Dine: / E C Lia Y V E _.._ Approvcl• ! Itcjcc[cd: ___ -•- i ,cd by Plan Review Comments: MAY 1 6 2016 1...,.________ ` artment review required Yes No uildlny.� `- * - ,, 1 !Dm ...aliment nin9&Zoning — _ Tree Administrator - - •I c Works Plaus Examiner u. is Safety _ —_ _. Fire Services --- — —•--- Date Cr••itA i/20/13 Rev.2 • riy-�% City of Atlantic Beach APPLICATION NUMBER s '\ Building Department ss� (To be assigned by the Building Department.) ++r800 Seminole Road Atlantic Beach, Florida 32233-5445 � H Phone(904)247-5826 • Fax(904)247-5845\ost»r E-mail: building-dept@coab.us Date routed:City web-site: http://www.coab.us /IQ APPLICATION REVIEW AND TRACKING FORM t7 (Pro Property Address: � 1V lA PATI3c < Department review required Yes�io Applicant: LOLL SOT H Ep S -nning &Zoni Tree Adminis rator Project: t V Etk [-4 rt fn 6. -ublic TYo • - Pui is Utili "u .fety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APATION STATUS Reviewing Department First Review: Approved. ['Denied. (Circle one. Comments: BUILDIN PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Deni d. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 1. s=-L`�•,V� City of Atlantic Beach fi ci Building Department APPLICATION NUMBER f 800 Seminole Road (To be assigned by the Building Department.) ��__ s: ��s., •• I . -SP ; Q v - Atlantic Beach, Florida 32233-5445 / Phone(904)247-5826 • Fax(904)247-5845 / s'''.ws»%' E-mail: building-dept@coab.us Date routed: IC) I ' City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 17 4 NAA12. r1 _ �G ��(� Department review required Yes No uildin Applicant: •[ bl—C_ g R_p?'H Ep_S, ening & Zoni t ' ` Tree dminis rator V Project: ` Elk) 't Q M deIlt1: y%lo: Pua 'c Uili i-,�fety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ` JApproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING - / Reviewed by: fes. � V G-- Date: f4%‘ TREE ADMIN. Second Review: [Approved as revised. ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. DDenied. Comments: Reviewed by: Date: Revised 05/14/09 I. sy>>`ir,r, City of Atlantic Beach RECEIVED APPLICATION NUMBER ' � Building Department (To be assigned by the Building Department.) is i=n,.,,,.i, ?' 800 SeminoleacRoad MAY 1 1 20io 1 ' y ; Q ��� �� Atlantic Beach, Florida 32233-5445 / Phone(904)247-5826 • Fax(904)247-5ik45 / \o;tl9r E-mail: building-dept@coab.us 1 Date routed: ,O City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: t7,4 I v `i J, _ �C OAK Dfe?epartment review required Yes No S uilarnc Applicant: •I b ROT�{ER S nning & Zoni Tree minis rator Project: 1 Etk) NO fY\ •ublic ►'o ��ub7icUtilii- , •u: . ,fety Fire Services Review fee $ Dept Signature • Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: QApproved. enied. (Circle one.) Comments: l /,,' I q( BUILDING `BGG 444i 1pfi %tCG�/ PLANNING &ZONING / �� Reviewed by: // Date: TREE ADMIN. Second Review: ('Approved as revised. ❑De• ed. PUBLIC WORKS Comments: It //$ jC id asaat,d, PUBLIC UTILITIES � PUBLIC SAFETY Reviewed by: 4-'3 / Date: S//6P FIRE SERVICES Third Review: []Approved as revised. ❑De ed. Comments: Reviewed by: Date: Revised 05/14/09 , S lApji•14,1 CITY OF ATLANTIC BEACH DEPARTMENT OF PUBLIC WORKS J3 ` s1 1200 Sandpiper Lane ....; J Atlantic Beach,FL 32233-4318 t) TELEPHONE:(904)247-5834 -" FAX:(904)247-5843 www.coab.us CONTRACTOR: DATE: 5-13-16 Toll Brothers, Inc. I PERMIT# 16-SFR-1093 160 Cape May Avenue gerh ' ' ADDRESS: 1764 Maritime Oak Drive Ponte Vedra, FL 32081 �} fAtlantic Beach, FL 32233 // /( /(� Email: arogers@tollbrothers.com �i� PERMIT APPLICATION FOR NEW HOME Your permit application has been by the Public Works Department for the reasons listed below. Please submit this information at your earliest convenience in order that we may approve your application. If you have any questions,please contact Scott Williams,Deputy Public Works Director at 904-247-5834 or email swilliams@coab.us. PUBLIC WORKS CORRECTION ITEMS: (Submit the following information to the Public Works Department) ** 'i - .imum driv- , . , •. i .• -of-way is 20'. ** Sidewa must go through driveway. PUBLIC WORKS CONDITIONS OF APPROVAL: (The following comments will be printed on your permit as Conditions of Approval) ** Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works(247-5834)for Erosion and Sediment Control Inspection prior to start of construction. ** All silt must remain on-site during construction. ** Roll off container company must be on City approved list and container cannot be placed on City right-of-way. (Approved:Advanced Disposal, Realco, Republic Services,Shapell's,Sunshine Recycling and Waste Pro). ** Full right-of-way restoration, including sod, is required. ** Maximum driveway width in City right-of-way is 20'with a 3'flare. cc: Toni Gindlesperger,Bldg.Dept. II-, - ,. .,:51- `lrR r j, City of Atlantic Beach Li J Building Department (� APPLICATION NUMBER -•t. ..-• A, ?' 800 Seminole Road �h' I. ,16 (To be assigned by the Building Department.) L� F,2 Atlantic Beach, Florida 32233- By: l - S ; Q . Phone(904)247-5826 • Fax 47-5845 / `' �,„9',- E-mail: building-de t coab.us —�` p @ Date routed: City web-site: http://www.coab.us — APPLICATION REVIEW AND TRACKING FORM Property Address: t77 4 ,� � �2�T1!V�C Q�K Department review required Yes No .uilcfin% Applicant: I ot:.,L 6 R_p`T• 4 Ep.S -Ai�-..nning & Zorn Tree A 'minis rator Project: 0 M dairy inegaiw Poi is Utili i-___, NtIlfc Safety Fire Services Review fee $ $.--h Dept Signature /'Ct,v _ Other Agency Review or Permit Required Review or Receiptt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI TION STATUS Reviewing Department First Review: It4pproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING -- � Reviewed by: y! Date: J�01 TREE ADMIN. • Second Review: I 'Approved as revised. ['Denied. AOC WORKS Comments: , PUBLIC UTILITIES -1 f& PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 .... .............. ... • • BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 1G —s FR - I O Ca 3 Job Address:1764 Maritime Oak Drive;Atlantic Beach,FL 32233 Permit Number: 1 Legal Description Lot 108 Atlantic Beach Country Clubf Unit1 67-I32-08-2S-29E.154 Parcel Valuation of Work S 320.857 Proposed Work Area heated/cooled 2,805 non-heated/cooled:771 Class of Work(circle one): 4210 Addition Alteration Repair Move Demolition Use of existing/proposed pool/spa window/door If an existing S�posed st uctore(s)((circle one): Commercial Residential structure,is a fire spnnkler system installed?(Circle one): , j N/A Florida Product Approval#See attached For multiple products use product approval form Describe in detail the type of work to be performed:New Residential Construction E0 Property Owner Information: © [ ll M Name:TOLL FL VI LIMITED PARTNERSHIP Address:I60 Cape May Avenue v City Ponte Vedra State FL Zip 32081 Phone 904 217- 739 E-Mail or Fax#(Optional)arogers@tollbrothers.com &JAY j 0 2016 Contractor Information: CONTRACTOR EMAIL,ADDRESS: arooc t?tollbrothe o Company Name:Toll Bros.,Inc.Qualifying Agent:Steven R.Merten Address:160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904 217-0739 Job Site/Contact Number 904 386-6472 Fax# State Certification/Registration#CGC 1510225 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bondin Company Name and AdMortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated I cern),that no work or installation has commenced prior to the =once of a permit and that all work will be performed t meet the standards of all laws regulating construction in this jurisdiction This permit becomes null and void ifworkisnot commencedwithinsispermits �or orifc tnst btr ctionntorjorki suspab nonedforaperiod ofsir 6J months at any time after work is commented I understand that separate Hada;Tanks and AirCondtione s,era Work, Signs,Wells Pools,Furnace Sorters WARNING TO OWNER: YOUR FLUE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certihr that I have read and examined this application and know the same to be true and correct Al! this type of work will be complied with whether specified herein or not The grantin of a permit does notpresume e�e of laws and ordinancesr cancelgovcelihee provisions of any other federal,state,or local law re:, sting construction or the performance ofconstruction. Stye authority to violate or the Signature of OwnerAl aSignature of Contractor I,, Print Name tev• ert ,!lP. Sr_Vice lat.iden Print Name Steven ' M -:r _ Before me Y Before me ,r of Ma 2016 this 9 tiara, av 21 6 Notary : Notary(46 Revised 0126.10 t o J'.,'r" ., MELISSA LI BERMAN 1 MY COMMISSION?FFCi5&tO5 ,• J;1t. 0 'rr�.. fid:'"A^+s. MELISSA LIEBERMAN •.?s;.,o�1 EXPIRES Sr.(;teml:nt 18 2017 •I MY COMMISSION t'FF05.�G05 (4071 398.01t3 I'Icr detotn,S,n cc.com `�:- t,c'�; ' • c,-a EXPIRES September 18.2077 (407)305.0153 Flo;idoNomry$nmce.com t R.O.W.Permit Attachment of for R.O.W.Permit# issued ,2016 Atlantic Beach,FL 32233 Owner's Name: Toll FL VI,LP Property Address: 1764 Maritime Oak Drive Atlantic Beach,FL 32233 Subdivision: Atlantic Beach Country Club Lot#/Block#: 108 R.E.#: 169505-1835 REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this day of ,20 ,by Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and Toll FL VL LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City.of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained,repaired,erected,and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30)days notice by CITY to the USER,said notice to USER shall be given by certified mail,return receipt requested,to the following address: 160 Cape May Ave.Ponte Vedra,FL 32081. The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon.the above-described property of the CITY,the USER chat(replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating,replacing,or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code,Building Codes,Land Development Code,and all other land use and code requirements of the CITY,including City Code Section 19-7(h)which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall,at the discretion of the CITY,be requested to submit'as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER DATED and SI II this q day of 2016. By: _41.4 Ste M ~Toll FL VI,LP. (to be signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this 9th day of May .2016,personally appeared before me,a Notary Public in and for said County and State, St.Johns.Florida ,the property owner of 1764 Maritime Oak Drive,Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instrument;who acknowledged to me that he or she executed the same freely and voluntarily and for the uses and purposes therein mentioned. 1 A'¢•, MELISSA LIEBERMAN No .r, ..c in for said County and State ' 1 MY COMMISSION 'FF05E605 a` af EXPIRES September 18.2017 CITY OF ATLANTIC BEACH,FLORIDA,a (407 358 0153 Flonclallo..arySarvice.c0111 municipal corporation: Approved: Doug Layton,Public Works Director For Permits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 NOTICE OF COMMENCEMEIN . 1 State of: FLORIDA Tax Folio No. 169505-1835 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 108 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E.154 Address of property being improved: 1764 Maritime Oak Drive,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD. HORSHAM, PA 19044 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor: TOLL BROS.,INC. Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): 06/30/17 THIS SPACE FOR RECORDER'S USE ONLY OWNER / Signed: Date: 279!14 Doc#2016050845,OR BK 17483 Page 537, Before me thi , 9 day of L in the Countyof Duval,State Number Pages:1 Of Florida,has personally appeared flol/eT(Pj .P_ Recorded 03/07/2016 at 08:26 AM, Notary Public at Large,State $f F orida,County of 0 oval. Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY My commission exp.iry s: .) RECORDING$10.00 Personally Known:V r7�� or PrAlu6,d.L,lcutifr�dtivtt. I l'`',17`°;%,:;,, MELISSA LIEBERMAN jpr MY COMMISSION#FF055605 o?,• EXPIRES September 18.2017 (407)390.0153 FlorldallotaryService.com /9611 ?+n►thadi 6414)€ - I / L19 I/7.To K f 408 *ale 6O x yip 0. VR2 gait p4)/61t, k IC Aro / ciez.170i 09fob Js r ✓j CITY OF ATLANTIC BEACH , er PUBLIC UTILITIES 1200 Sandpiper Lane ATLANTIC BEACH, FL 32233 4 01119r (904)270-2535 or(904)247-5874 NEW WATER/SEWER TAP REQUEST Date: -5--//— /Co Project Address: / 7(c T 111,4 2( T( M 04-t( Dr- No. of Units: I Commercial Residential Multi-Family 3/ '' New Water Tap(s)&Meter(s) Meter Size(s) q New Irrigation Meter `/ Upgrade Existing Meter from to (size) New Reclaim Water Meter ✓ Size 3, New Connection to City Sewer ✓ Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# /(o --,..5 cR- la ' 3 Water System Development Charge $ (7 Ob Sewer System Development Charge $ Q 5D, DiI Water Meter Only $ /155, 06 Reclaim Meter Only $ ( 4 5 . p >��b O Water Meter Tap $ (notes) Sewer Tap $ Cross Connection $ 50, DD Other $ TOTAL $S(o /0 , 00 APPROVED: Kayle Moore, PE Yor.\ (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED BUILDING PERMIT APPLICATION FILE COPY CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 ( — S FR — ( Q c-13 Job Address: 1764 Maritime Oak Drive:Atlantic Beach,FL 32233 Permit Number: Legal Description Lot 108 Atlantic Beach Country Club Ugnit 1 67-I32-08-2S-29E.15g4.Ft Parcel Floor Valuation of Work$ 320.857 Proposed Work fheated/Cooled 2,805 non-heated/cooled 771 Class of Work(circle one): 42110 Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed?(Circle one): .417/1110 Florida Product Approval 4 See attached For multiple products use product approval form Describe in detail the type of work to be performed:New Residential ConstructionL� (�-� t v Property Owner Information: Name:TOLL FL VT LIMITED PARTNERSHIP Address: 160 Cape May Avenue City Ponte Vectra State FL Zip 32081 Phone 904 217-0739 MAY E-Mail or Fax 4(Optional)arogersollbrothers.com 1 0 2016 ®t Contractor Information: CONTRACTOR EMAIL ADDRESS: aro"eriy tollbrothe ._ o Company Name:Toll Bros.,Inc.Qualifying Agent:Steven R,Merten Address:160 Cape May Avenue City Ponte Vedra State FL Zip 32Q8i Office Phone 904 217-0739 Job Site/Contact Number 904 386-6472 Fax 4 State Certification/Registration#CGC 1510225 • Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of oil laws regulating construction in this jurisdiction. This permit becomes mill and void if work is not commenced within six(6)months,or ifeonstruction or work is suspended or abandoned for a period of sir(6)months at env time after work is commenced I understand that separate permits must be secured for Electrical Work,Plumbing,Signs,Welk,Poals,Furnaces,Bailers, Heaters,Tanks and Air Conditioners,etc WARNIN COMMENCEMENT MAY RESULYOUR IN YOUR FAILURE EYITNG TTWIORD A CEE FOR IMPCE OF ROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this a lication and know the same to be true and correct. A11 provisions of laws and ordinances governing this tlpe of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state,or local low reN ating construction or the performance of construction. Signature of Owner /fi/ Signature of Contractor g Print Name teven •.Merten .'. Sr.Vice ' • ident Print Name Steven R.M Before me Before me this 9 Day_of May ,2016 this 9 . .f May .2016 Notary4,7,0„ Notary+ bh• Revised 01.26.10 t "d MEL SSA LIEBER:.iAN COMI.IISrICN FFfr56d05 ;a>'pAr6^. lviELiSS.4 LIEBERMAN EXPIRES Sr:1geribc:la 2017 ; ta'i COMMISSION:,FFo55605 µ071390.C1rl 53 cndoos mvxr;ecan �•`-e `'. EXPIRES SP';Enlbur 18.2017 V (407139.4'0153 FIo:ldako!ahSor.re.con FILE COPS . DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w pp / Conditions Review Initials/Date: /11! , 5-4,9./6 Development Size t�/1 Habitable Spaced o � F; Non-Habitable 7 72 S, Impervious area Miscellaneous Information Occupancy Group le-3 Type of Construction V6 Number of Stories �2 Zoning District /-1-13 G 6-- Max. Occupancy Load Fire Sprinklers Required Flood Zone , Conditions/Comments: FILE Ccr' R.O.W.Permit Attachment of for R.O.W.Permit# issued ,2016 Atlantic Beach,FL 32233 Owner's Name: Toll FL VI,LP Property Address: 1764 Maritime Oak Drive Atlantic Beach,FL 32233 Subdivision: Atlantic Beach Country Club Lot#/Block#: 108 RE.#: 169505-1835 REVOCABLE ENCROACHMENT PERMIT PHIS REVOCABLE ENCROACHMENT PERMIT,issued on this day of ,20 ,by Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and Toll FL VI,_LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH. That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained,repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30)days notice by CITY to the USER,said notice to USER shall be given by certified mail,return receipt requested,to the following address: 160 Cape May Ave.Ponte Vedra,FL 32081. The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating,replacing,or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code,Building Codes,Land Development Code,and all other land use and code requirements of the CITY,including City Code Section 19-7 (h)which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoini g sidewalks." Page 1 of 2 FILE CC -y/ The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall,at the discretion of the CITY,be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit chall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. DATED and SI .1 'this 9 day of ,2016. By: .s'41, S M-''Toll FL VI,LP. (to be signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this 9th day of May ,2016,personally appeared before me,a Notary Public in and for said County and State, St Johns.Florida ,the property owner of 1764 Maritime Oak Drive,Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instrument;who acknowledged to me that he or she executed the same freely and voluntarily and for the uses and purposes therein mentioned. " `" MEL;SSA LIEBERMAN �' No : b;c in for said County and State • 7•�: .j MY COMMISSION"FF055605 •\?a.nom' E XPI RES September t8.201, CITY OF ATLANTIC BEACH,FLORIDA,a (4p'I'`{`Q153 Flo,dallolarvso,tCe.tom municipal corporation: Approved: Doug Layton,Public Works Director For Permits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 f2erm;/ . /d- S'/R-- /0 93 FILE COPY NOTICE OF + COMMENCEMIIN State of: FLORIDA Tax Folio No. 169505-1835 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 108 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E.154 Address of property being improved: 1764 Maritime Oak Drive,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD. HORSHAM,PA 19044 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor: TOLL BROS.,INC. Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN Address: 160 CAPE MAY AVE. PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): 06/30/17 THIS SPACE FOR RECORDER'S USE ONLY OWNER ! I Signed: Date: 9/C4 Doc#2016050845,OR BK 17453 Page 537, Before me thi ,17 4j day of in the Coun of Duval,State Number Pages:1 Of Florida,has personally appeared ''f lo,(n TJ u/?u Recorded 03/07/2016 at 08:26 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL Notary Public at Large,State .f F orida,County of B uvak COUNTY My commission expir s: q .I RECORDING$10.00 Personally Known:V or Pr,nlul,Fil.I,dmi tiftualiult. ;•'PY pV'• " a MELISSA LIEBERMAN Alit }'I MY COMMISSION#FF055605 `N Fide EXPIRES September 18.2017 (407)390.0153 FloridallotaryService.com NoDOOvo, cn :PwN y9:i 0. cn � w N y .< -,, a 0cb 'tia 'rIdc-" � oarVI Cl) cn o Q, a• 0 -.• 0. c• fD N' =° >= o' cm y o a- R. a, b boo � � 0., o F. n c CD xO ?; ° w w til o o C • 0. �• F w c c -* 0 " a -• << a 0 o � Voao- c V 0 ta c o -a Z o G y 0 CD 0 -, 0 0 o CA °= < Q N 0 4 to Cr 0 CD �• W .74 N O co < g 'U� C ��` Cr CD DJ P1 O C) -moi O COQ, < O. 7C n NO C 2 ° � 0 ,..e. � ? d 4. H a ' .. °CD < b A o oo CD e • o 0 a 0 -, ¢' Y c w o 6 o C" ( C) ,� C a W (D 7 DD .S En• CD CD Cr Co H .1 0 'd O w n It Q = c 0 r 7 b c •. O w ry FS 0. N CD N •C7 N 00 W O OO cD Z co t 0 Cl) N Cri ED- ::-..- c 5' S' �' c a• 0 0 0 b 's1 V) o < <e B . o 0 0., -, CD I p U7 ,„ <ta. -n X cn 0 D y Cr, n '0 �• 'D 0Oo J 0-1 ~ X ° d 77' `< o.. P a. xH Q (DD o CD cu 5 C1 0. = G. 0 Q, Q. N .� . fD �, .)-r ,0 Q. c Q - c� B - n c o z C" � v o W Z � � + + z Z 5 o Z iy o y o 0 0 0 , y a ° _ A W U, u,`rl O o 0 0 u� y ,_, y ,_ p' 00� -0 CrJ -n Cs ,0.� • o n N o co � < co 5 = C r -n -n -n "n -n'-n -n -n -n -n v) dQ O CSD G t- r- r r rr r rrrg• 0 - c N ti PO 00 o O o 00 - t N .a. OA a .. Q d _..,= CD • O t..) - CA Ut N 000 ,'n i' a N Q\ ? O\ 5 G.) J r -71 CA CD a �. CT r w 0 ,.n to 00 ,.' -# r ,-- O N CD UI ..i. oo ,D N limn W I.- r n-I 0 A 4t O 1 1� J G1 In A W N O `J • •• • In A W N - D _. O O 00 J O\ tA A W N --• n p (4xnr � � � oov)• oa > x 0v) 04C) c � m o cr, No v (7) ' o ao o ° m o � C co fl� o o mo o . o 0. -0O n_ y >v W ^' '. 0 "� va Ora 'o Q. TS n (Ia ti '(J ^. O N c 5 a Com" OG cs (o _ ot v m a. b go p N is '-•< CL a: o a y 0: N v, copr -<iei w v' �! O S N (D• N (. C N 00 5• �h A? ] O UQ �y E 0 N C .a -. t1 v° (JO 3 v 3 0 n vN C ••••m I (pc p C UQ p coCA c v Oa O n 0 co ? CO C7 / w '/' w m - 2, o D w n 3 3 a -. a W� O -r1 N S (D T 0 CL o 0 o a) x a) x o c n s' nco - 3 i _ • n '0 0. O Q. ryc 0. N co 3 co N CO CO A: - w .1 < - O � f (J (fa o -0 ? - O O r 0. n. - C n 0 U IP 7 0 n n y I l N T •--I '/ 0 0 r r - c to cn 0. a -o -u n n. 0 -• o 0 n sv w 3' 3' n. 3• 0 a 7 CD a go Oa n !la77 w w v w 0 N W 3 .� v) v) n. C 0 ? 0- 0 CL y 3 3. VJ Cl) n D (Ia (IQ = A) 3 n a N O n T. 0 en - CD a V) ') 0 7 n -0 go U F 0 0' Z z z + a „ y r ;- 5-_,.. D D Do 3• o D' 0' 0 0 C w CD •71 'T.1 -1 'T1 -71 -r. ' -0 ^z7 -r7 -n r r r r r r r r r N w N .f-. CO O O t,..) (.J � N 4 A -4 W - •- O O N • O .-• O J-. N O O CN O O J A . � V ._. �- CO 00 LA Oo N /) - _. _ l.,J ••-• --• A W N ( N W O O O CO lJ .- n It, n > N - x QQ -.4N '-' n .0 ] W N u, .p — n ;i A W N CN LA 0-0 Cil • a CD P {A y o o w 3 C o '� sZ 0 0 0 C. n z 9D o o �" fD o ti o. .' cu IA (IQ coco v o o C n w ¢ �] TO cu °: o CI rJ o 1-3 o w 0- o >C G� •- o w c��c n• CD 0 CS7 �-3 co C�ryJ ►d 1 N a I r/]a — O Cr1 x 9 "3 Zcrq p. la o � �' a teaCr r S. UQ r) o O '-. O C .--. cro o- (D a O •O a O a � H �Q • ' N wro O _ T rrl a 0 .ti 77 CI. O y D) U n < a. 2 �' O •co a' - 2 C 2 ElD ^a, f a.. r^ EE N N O 0 09 In a CO •0 n ^ CD '••" i C) . 0 a 0 o m 17 =' a. CD F UQ O w CT P6) 0 rs. 7 'r1 rrm — V% - 0 bC'0 V) c o O ,..< w n Da y 0 O CD n a ' D w 0 At G C) 0 coCD C; C) CD co a- o ~ 0 - n p - "0 0 0. 'n.• cr -, a -, m `-R 0 CIO In -, j. 5 a. / a. pa cn o 3Y r' "CSC) O . CD A CD V� 0. "i a O F.17; a a. 0 O O a a a In y N a' O a N. a. . -a ^D a r (D CD P^ n J- 00 0 7 y NJ (JQ (J_ E rr 1J W " 7• W f a a' Cr (IQ (lc lt C CD =Ii CD CD-3 0- 0- ° 'cs -I fD nom. o Z Z b o. Z `+ > v, 0 C 3 0 y 3 z w- o 0- Q- 6• CD co �' (D A (n n ^ N 3 t3. O cD 0 -t . - O N W O tt (....) l',.) n OQ, 1 -0 O NO, N zO 0 -0, 3 v w <WN � — CD (D N• FD ,cr 2 cD - 0 `D a CO A 0. 0 G. 0 0 ':.h C W N • N 0 M 3 x- 0 O Fr C17 -n s UQ o z P C a. a G' a co ivi "i70- N r ., C) co _A o N rt C) C 0 Sy N N (D \% 2, 0 Q y nh W a N S N ry O �° LT...... 0 co 0 til 0 n 3 �_.o o L 0 2.C O. 5 5 coO 0 CDN . , FILE COPY :,. . . FORM R405-2014 - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cumberland 2805 Right NE Builder Name: Toll Brothers Street: 1764 Maritime Oak Dr.(Lot 108 AB) Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: • Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(3327.8 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 3146.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 181.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (2189.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1857.00 ft2 6. Conditioned floor area above grade(ft2) 2805 b.Under Attic(Vented) R=19.0 332.00 ft2 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(317.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 780 a. U-Factor: Dbl,U=0.33 317.00 ft2 SHGC: SHGC=0.30 ft2 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a.Central Unit 42.0 SEER:14.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 3.838 ft. 14.Hot water systems Area Weighted Average SHGC: 0.300 a.Natural Gas Tankiess Cap: 1 gallons 8. Floor Types (2805.0 sqft.) Insulation Area EF:0.600 a.Slab-On-Grade Edge Insulation R=0.0 2189.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 616.00 ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 65.43 PASS Glass/Floor Area: 0.113 Total Baseline Loads: 71.29 rry I hereby certify that the plans and specifications covered by Review of the plans and ,,a4 01 STAB'"•,� this calculation are in compliance with the Florida Energy specifications covered by this ��` , Vin,=r •..9,A% ' , Code. f calculation indicates compliance �co r 411• p, ;f� 5z-...sz• , if / with the Florida Energy Code. h'rura =t'�:• : ,1t • PREPARED BY: �' Before construction is completed r�: "" "' . DATE: O 4 T le this building will be inspected for ..;___,j r compliance with Section 553.908 ` * ..• .i. ':4 : *1 Florida Statutes. ° ' " ,e I hereby certify that this building,as designed,is in compliance l' � with the Florida Energy Code. ' 4`'«OD ''`' OWNER/AGENT:__ -- _IAA BUILDING OFFICIAL: ill 5-�/Q .l6 9" ___ DATE: 5( IG] Li' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ' certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. . . 4/6/2016 2:59 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 j FORM R405-2014 PROJECT Title: Cumberland 2805 Right NE Bedrooms: 4 Address Type: Street AddressLot# Building Type: User Conditioned Area: 2805 Owner. Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: 1764 Maritime Oak Dr. Permit Office: Duval Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , . FL, Family Type: Single-family New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 . Block1 2805 27434 SPACES Number Name Area VolumeKitchen Occupants - Bedrooms_ IanID Finished_ _ Cooled Heated 1 Main 2189 21890 Yes 4 3 1 Yes Yes Yes . . 2 2nd Floor 616 5544 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile_ Wood Carpet 1 Slab-On-Grade Edge Insulatlo Main 213.4 ft 0 2189 ft2 -_— 0 0 1 V 2 Floor Over Other Space 2nd Floor ---- --- 616 ft2 0 0 0 1 • ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested insul. (deg) • V 1 Gable or Shed Composition shingles 2535 ft2 640 ft2 Medium 0.8 N 0.9 No 0 30:3 ATTIC V .. # Type Ventilation Vent Ratio(1 in) Area RBS IRCC V 1 Full attic Vented 300 2189 ft2 N N I + liant Software • Page 2 of 5 4/6/2016 2:59 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Comp FORM R405-2014 CEILING - 1 Space R-Value Area Framing Frac Truss Type Y # Ceiling Type 0 11 Wood Main 38 1360 ft2 1 Under Attic(Vented) 0.11 Wood 3 Under Attic(Vented) 2nd Floor1 i V 2 Under Attic(Vented) 38 497 ft20.11 Wood Main 19 213 ft2 0 11 Wood ___V,.. 4 Under Attic(Vented) 2nd Floor 19 119 ft2 WALLS Sheathing Framing Solar Below / Adjacent Space Cavity Width^ _E 1n-Area FOValue-Eractioa�bsor�rade.%_ �L#-Ort_ To all_T_ypP R-Value-Et^I.. - 1 NE Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.5 0 V 2 NE Exterior Frame-Wood Main 19 19 10 10 0 198.3 ft2 0 0.23 0.5 0 ✓ 3 NW Exterior Frame-Wood 2nd Floor 19 19 7 9 0 176.3 ft2 0 0.23 0.5 0 I _ V 4 NW Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 0.23 0.5 0 5 SW Exterior Frame-Wood 2nd Floor 19 40 0 8 0 320.0 ft2 0 0.23 0.5 0 ✓ 6 SW Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.5 0 ✓ 7 SE Exterior Frame-Wood 2nd Floor 19 19 7 8 0 156.7 ft2 0 0 23 0.5 0 8 SE Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 V 9 NE Garage Frame-Wood Main 13 20 2 9 0 181.5 ft2 0 0.23 0.01 0 DOORS Storms U-Value Width Height Area - V # Ornt Door Type Space Ft In Ft _ In None .4 3 8 24 ft2 _V--. 1 NE Insulated Main 21.3 ft2 2 NE insulated Main None .4 2 8 8 WINDOWS Orientation shown is the entered,Proposed orientation. Overhang Wall Area Depth Separation _Int Shade _ Screening- # Ornt ID Frame Panes NFRC U-Factor SHGC V 1 NE 2 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 7 ft 0 in 1 ft 0 In Drapes/blinds Interior 5✓ 2 SE 8 Vinyl Low-E Double Yes 0.33 0.3 75.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds interior 5 __V___ 3 SW 6 Vinyl Low-E Double Yes 0.33 0.3 4 SW 6 Vinyl Low-E Double Yes 0.33 0.3 72.0 ft2 10 ft 0 in 1 ft 0 in Drapes/blinds Interior 5 45.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Interior 5 5 SE 7 Vinyl Low-E Double Yes 0.33 0.3 V 6 NW • 4 Vinyl Low-E Double Yes 0.33 0.3 20.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 30 0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 7 NW 4 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Interior 5 ___V___ 8 NW 3 Vinyl Low-E Double Yes 0.33 0.3 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation ____V- 1 475 ft2 510 ft2 51 ft 9ft 1 . Page 3 of 5 4/6/2016 2:59 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software 1 I FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 { 1 Wholehouse Proposed ACH(50) .000311 2286.2 125.51 236.04 .2946 5 !i HEATING SYSTEM V # System Type Subtype Efficiency Capacity_ Block Ducts lit HSPF:8.2 42 kBtu/hr 1 sys#1 J 1 Electric Heat Pump SP COOLING SYSTEM V # System Type Subtype Efficiency Capacity Alr Flow SHR Block Ducts V 1 Central Unit Split SEER: 14 42 kBtu/hr 1260 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation • 1 Natural Gas Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF ft2 V None None DUCTS V —nSupply —Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool ✓ 1 Attic 6 780 ft2 Attic 520 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr May X Jun X Jul X Au S:11;• Oct Nov Dec Jan Feb � Mar Apr Ma Jun Jul 4 Aug Oct X Nov Dec Heating 1X Jan Feb [X Mar LXX Apr 1 I May t t Jun t 'Jul [ 'Aug �i Sep tXl Oct XI Nov Dec Venting • I gy 4/6/2016 2:59 PM Ener Gauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 • 1 I FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 0 80 80 0 Cooling(WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 8 78 r Heating(WD) AM 66 68 68 68 68 68 68 66 66 68 68 8 68 8 68 66 8 68 68 Heating(WEH) PM 66 66 66 66 66 68 68 68 68 68 68 66 MECHANICAL VENTILATION Time Cooling System Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Ti_ None 0 0 0 1-Electric Heat Pump 0% 1 -Central Unit • 1 • il . I i Page 5 of 5 4/612016 2:59 PM EnergyGaugee USA-FlaRes2014 Section R405.4.1 Compliant Software 0 ' FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD . ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index, the more efficient the home. 1764 Maritime Oak Dr. (Lot 108 AB) , Atlantic Beach , FL, . 9. Wall New(From Plans) R= 9.0 314 Area ft2 1. New construction or existing TypesInsulation a.Frame-Wood,Exterior R=19.0 141.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent N/A R c. ft: 4. Number of Bedrooms 3. Number of units,if multiple family 1 d.N/A R= ft: 4 10.Ceiling Types Insulation Area R=38.0 1857.00 ft2 CR=19.03332.00 ft2 5. this a worst case? No a.Under Attic(Vented)b.Under Attic(Vented) R= ft2 6. Conditioned floor area(ft:) 2805 c.NIA R ft: i a Description Area 11.Ducts 6 780 7. Fws" 317.00 ft2 a.Sup:Attic,Ret:Attic,AH:2nd Floor a. U- U-Factor: Dbl,U=0.33 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: ft: a.Central Unit 42.0 SEER:14.00 . � c. U-Factor: N/A • SHGC: ft2 kBtu/hr Efficiency d. U-Factor: N/A 13.Heating systems 42.0 HSPF:8.20 SHGC: a.Electric Heat Pump Area Weighted Average Overhang Depth: 3.838 ft.0.300 Area Weighted Average SHGC: 14.Hot water systems Cap:1 gallons 8. Floor Types Insulation Area a.Natural Gas EF:0.6 a.Slab-On-Grade Edge Insulation R=0.0 2189.00 ft2 b.Floor Over Other Space R=0.0 616.00 ft2 , b. Conservation features c.N/A R= ft2 None Pstat 15.Credits • • I certify that this home has complied with the Florida Energy Efficiency Code for Building �,'`' `0HEST • L �i(,.iaia z h. 3 ' i y`rr c;.``•:� els Construction through the above energp•saving features which will be installed (or exceeded) ,�� //',��,. ° - o�� in this home before final inspection. Otherwise, a new EPL Display Card will be completed . y , .t;,,,,a�. $ based on installed Code comp i-nt features. - • r= / Date: 5 p i,�': -��_:.,-- � Builder Signature: �J�A '- *. , L • - � pr. City/FL Zip: /�81 S-<- 3Z233 ' �%.�. .'`'• X63� Address of New Home: Roy (�/�Ct.vrhfY� on "�,.��D WL."*. `Note: Thisis hot a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient i mortgage (EEM) incentives if you obtain a Florida EnerauGauge lingfo mationtand a list of certf ed Rthe EnergyGaue aters. For (321)For 638-1492 or see the EnergyGauge web site at energyg ge com for information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ` I • Page 1 of 1 4/6/2016 3:02 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software I ' FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods Number: NumI ' ADDRESS: 1764 Maritime Oak Dr.(Lot 108 AB) Permit Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 5( 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law • [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and • nonpresold In a d ellinglunit.The building officialbdings.The EPLlay shall verify that the card contains fEPL display ormation Indicating ard completed dgy and signed by the builder accuratelyreflectsperformance level and efficiencies of the plans Inst and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. 12 R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. !I • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air • changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an • approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,If installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if Installed at the time of the test,shall be fully open. yS R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air Infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. / R402.4.4 Recessed lighting. Recessed luminaires Installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. / R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified In accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 13 min)per square feet(9.29 m2) f oned floor area 1 when tested att anpessure differental tie shall iial of 0.1 nchese less than or equal to 4 w.g.(25 Pa)across the entire system,ncluding the manufacturer's air hand err enclosure.All register boots shall be taped or otherwise sealed during the test. 100 square feet(9.29 m2)of conditioned floor area when tested 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)perq handler enclosure. tato a taped otherwise sealed during the test. If the air handler l of 0.1 inches w.g.(25Pa)across tis not installed ae system, tlthe ng tt me of the test,total he manufacturer's rleakage shall be less All than or equal tol3 cfm (ape (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 41612016 3:02 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 • • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.3 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., 7o R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. • 12( R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. vi R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls o capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). o R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. • dR403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida•Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in Installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. pi R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive Indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3• If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. x" R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the • equipment shall not be less than the calculated latent load. 4/6/2016 3:02 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for retum side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that Its cooling capacity Is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. rf R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design • requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation Is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and In accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance • with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. p R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. p R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights if R405.2 Performance ONLY. All ducts not entirely Inside the building thermal envelope shall be Insulated to a minimum of R-6. R405.2.1 Performance ONLY. Ceilings shall have minimum Insulation of R-19.Where single assemby of the exposed deck and beam type or• concrete deck roofs do not have sufficent space,R-10 is allowed. 4/6/2016 3:02 PM EnergyGaugee USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 ,• AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cumberland 2805 Right NE Builder Name: Toll Brothers Street: 1764 Maritime Oak Dr.(Lot 108 AB) Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: . Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the ' insulation and,any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. • Corners and headers shall be insulated and the junction of the foundation . Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and / framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. , Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside. / and cantilevered floors) of subfloor decking. The air barrier shall be Installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or / unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled / by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be 7//,. air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in / exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. } Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air / barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or / air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have 7r gasketed doors i 1 i 4/6/2016 3:03 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 l I i I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Cumberland 2805 Right NE Builder Name: Toll Brothers Street: 1764 Maritime Oak Dr.(Lot 108 AB) Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Design Location: FL,Jacksonville .Jurisdiction: 261300 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: _.._..... _ n: R: CFM(50): Single or Multi Point Test Data ELA: HOUSE PRESSURE I FLOW: Eq LA: ACH: ACH(50): • SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour In Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: , 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures; 3.Interior doors,if Installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,If installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, p��1..._.E S ATS`•�,,� performance results demonstrate compliance testingshall be conducted by an ��' N.'%;,� - 0�`, t with Florida Energy Code requirements in approved third party.A written �, , ; ,.� �. ,e report of the results of the test shall ' ""'' ; :;' �;,;:, s accordance with Section R402.4.1.2. P be signed by the third party ;: 911-94, ts • conducting the test and provided to a Kf SIGNATURE: the code official. X41`V ..... .. .. 4 „go .. . .......... .............. ....... DATE: DATE: i 4/6/2016 3:03 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Softer Page 1 of 1 I I i • 1KcGOVvan Project Summary Job: Lot 108 ABCC !Malaga Air Date. 4/6/2016 Cp...4.. ing Entire House By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278.0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Notes: Cumberland Bonus Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 28694 Btuh Structure 23423 Btuh Ducts 4613 Btuh Ducts 5808 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32925 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28938 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4140 Btuh Ducts 1018 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(f12) 2805 2805 Equipment latent load 6648 Btuh Volume(tt3) 28507 28507 Air changes/hour 0.32 0.16 Equipment total load 35586 Btuh Equiv.AVF(cfm) 152 76 Req.total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB042 Cond CH14NB042 AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8.2 HSPF Efficiency 11.3 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 37600 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 28 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1400 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Apr-06 13:46:43 - - wrightsoft• Comfort Builder by wdghtsoft 15.0.23 RSU12270 Page 1 C ...n\Toll Brothers\Cumberland Bonus 2805 Right.rup Calc=MJ8 Front Door faces:NE / First Floor N MASTER WIC' MASTER BEDROOM'; 8x4 4" 14x6 8" 8x4 16x16 I "'''l • ER �1 6 x12 To T 3"Fan 7" ;J 6x10 3"Fan 6" ���i 16x16 10" ma ROOM' 14" 3"Fan no �m 6x10 7" 6 x 12 BATH 2l 7"8x4 :EDROOM2 OT 4., 'LINEN ■ :_':`1 ■ r 12x12 12" HALLWAY: 8" I 14" Sup Riser ................ 18" 12" STAIRS: 16"■ E Sup Riser • Ret Riser 1<.; : CHEN 12" 20" 20" 10x10 10x6 6x10 - 12 x6 12" ®y®9" ,,, 7"... 6" :. DROOM 3 I \ 7" • 10x10 _ - PANT: Eirti ■ , p. ■ "4 10" 4" '•, fr r1 10 12x12 6"x6 18x18 8" 16" DINING R 1 OM 9" ■ FOYERI R. 10 x6 GARAGE 12x6 6" 7" d LIVING ROOM ) r o Job#: Lot 108 ABCCMcGowan's Heating & Air Conditioni... Scale: 1 : 103 Performed by Stephen Barber for: Page 1 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.23 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2016-Apr-06 13:47:34 www.mcgowansac.com korey@mcgowansac.com ...\Cumberland Bonus 2805 Right.rup . '41' 1' N up 3"Fan WIC NV II 8 x 4 ., ►� 6x14 4 BATH 3 .. � � 8x4 ! II 6x12 8" 4„ =g. BED 4 II 11Wirmidli M i 8 12x12 6 x 10 12" 5" STAIRS UP Ret Riser Sup Riser Sup Riser 20 18" 12" 20" Job#: Lot 108 ABCCMcGowan's Heating & Air Conditions... scale: : 103 Performed by Stephen Barber for: Page 2 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 15.0.23 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2016-Apr-06 13:47:34 www.mcgowansac.com korey@mcgowansac.com ...\Cumberland Bonus 2805 Right.rup McGowan Manual S Compliance Report Job: Lot 108ABCC Date: 4/6/2016 floating 8Air itgov ConditioningEntire House By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 28938 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 6648 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 35586 Btuh Indoor RH: 50% Estimated airflow: 1400 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042+FB4CNP042 Actual airflow: 1400 cfm Sensible capacity: 28904 Btuh 100%of load Latent capacity: 6729 Btuh 101%of load Total capacity: 35633 Btuh 100%of load SHR: 81% Heating Equipment IDesign Conditions Outdoor design DB: 31.7°F Heat loss: 32925 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CHI4NB042+FB4CNP042 Actual airflow: 1225 cfm Output capacity: 29316 Btuh 89%of load Capacity balance: 30 °F Supplemental heat required: 3609 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 9.6 kW 100%of load Temp. rise: 21 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Apr-0613:46:43 4- ' ,,s wrightsoft' Comfort Builder by Wrightsoft 15.0.23 RSU12270 Page 1 A ...n\Toll Brothers\Cumberland Bonus 2805 Right.rup Calc=MJ8 Front Door faces:NE McCowan Duct System Summary Job: Lot 108 ABCCDate: 4/6/2016 NontmgaAh Cdndltbning Entire House By: Stephen Barber K ucu McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers FI Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.234/0.156 in H2O 0.234/0.156 in H2O Lowest friction rate 0.056 in/100ft 0.056 in/100ft Actual air flow 1225 cfm 1400 cfm Total effective length(TEL) 702 ft Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH 2 c 1 0 0 0.067 4.0 Ox 0 VIFx 60.8 290.0 st6 BATH 3 h 456 17 16 0.081 4.0 Ox 0 VIFx 62.3 225.0 st9 BED 4 c 2402 93 115 0.080 7.0 Ox 0 VIFx 67.9 225.0 st9 BEDROOM 2 c 1283 58 61 0.066 7.0 Ox 0 VIFx 63.8 290.0 st6 BEDROOM 3 c 1865 84 89 0.078 6.0 Ox 0 VIFx 56.8 245.0 st3 DINING ROOM c 1836 64 88 0.080 6.0 Ox 0 VIFx 41.7 250.0 st3 FAMILY ROOM c 2480 98 119 0.077 7.0 Ox 0 VIFx 48.8 255.0 st5 FAMILY ROOM-A c 2480 98 119 0.076 7.0 Ox 0 VIFx 59.8 250.0 st5 FOYER h 1891 70 63 0.068 6.0 Ox 0 VIFx 57.3 285.0 st4 KITCHEN c 2067 53 99 0.084 7.0 Ox 0 VIFx 37.2 240.0 st3 LAUDRY c 1424 34 68 0.079 7.0 Ox 0 VIFx 51.4 245.0 st3 LIVING ROOM h 3524 130 99 0.069 7.0 Ox 0 VIFx 52.8 285.0 st4 LOFT c 3663 122 175 0.082 8.0 Ox 0 VIFx 55.2 230.0 st9 MASTER BATH c 1402 55 67 0.056 6.0 Ox 0 VIFx 82.5 335.0 st7 MASTER BEDROOM c 2984 124 143 0.056 8.0 Ox 0 VIFx 85.8 335.0 st7 MASTER WIC h 1825 67 32 0.056 4.0 Ox 0 VIFx 86.1 335.0 st7 PANTRY h 414 15 7 0.081 4.0 Ox 0 VIFx 42.2 245.0 st3 STAIRS UP h 939 35 28 0.082 5.0 Ox 0 VIFx 58.8 225.0 st9 TOILET c 53 1 3 0.056 4.0 Ox 0 VIFx 85.3 330.0 st7 wlc h 258 9 8 0.079 4.0 Ox 0 VIFx 64.6 230.0 st9 2016-Apr-06 13:46:43 ,` wrightsoft' Comfort Builder by Wrightsoft 15.0.23 RSU12270 Page 1 AC A ...n\Toll Brothers\Cumberland Bonus 2805 Right.rup Calc=MJ8 Front Door faces:NE Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st9 Peak AVF 277 343 0.079 437 12.0 0 x 0 VinlFlx st8 st7 Peak AVF 247 244 0.056 452 10.0 0 x 0 VinIFIx st6 st6 Peak AVF 304 306 0.056 389 12.0 0 x 0 VinIFIx st5 st4 Peak AVF 199 162 0.068 451 9.0 0 x 0 VinIFIx st3 st3 Peak AVF 449 514 0.068 654 12.0 0 x 0 VinlFlx st2 st5 Peak AVF 499 543 0.056 508 14.0 0 x 0 VinlFlx st2 st2 Peak AVF 948 1057 0.056 757 16.0 0 x 0 VinlFlx st1 st8 Peak AVF 277 343 0.079 437 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1225 1400 0.056 792 18.0 0 x 0 VinlFlx Return Branch Detail Tele Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 193 199 200.4 0.078 143 16.0 Ox 0 VIFx rt3 rb2 Ox 0 381 407 262.9 0.059 1167 8.0 Ox 0 VIFx r14 rb3 Ox 0 375 450 280.9 0.056 1290 8.0 Ox 0 VIFx rt4 rb7 Ox 0 277 343 121.3 0.129 437 12.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt4 Peak AVF 756 858 0.056 1572 10.0 0 x 0 VinIFIx rt3 rt3 Peak AVF 948 1057 0.056 484 20.0 0 x 0 VinIFIx rt2 rt2 Peak AVF 948 1057 0.056 484 20.0 0 x 0 VinIFIx rt1 rt1 Peak AVF 1225 1400 0.056 792 18.0 0 x 0 VinlFlx 2016-Apr-06 13:46:43 a wrightsoft' Comfort Builder by Wrightsoft 15.0.23 RSU12270 Page 2 ACcA ...n\Toll Brothers\Cumberland Bonus 2805 Right.rup Calc=MJ8 Front Door faces:NE I