Loading...
23 CORAL ST - ENERGY SHEETS OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CoralSt BuilderName: PILLAR CONSTRUCTION Street: CORAL STREET Permit Office: Duval City,State,Zip: ,FL, Permit Number: Owner: Jurisdiction: 261000 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(3755.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3440.00 ft' b.Frame-Wood,Adjacent R=19.0 315.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 4 d.N/A R= ft' 10.Ceiling Types_(1980.0 soft.) Insulation Area 5. Is this a worst case? No a.Roof D Unvented _ R=20.0 1980.00 ft' 6. Conditioned floor area above grade(ft') 3260 b.N/A R= ft2 Conditioned floor area below grade(ft') 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(620.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 652 a. U-Factor: Dbl,U=0.35 620.00 ft' SHGC: SHGC=0.29 b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 40.0 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 40.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.318 ft. Area Weighted Average SHGC: 0.290 14.Hot water systems 1 8. Floor Types (1972.0 sqft.) Insulation Area a.Natural Gas Tankless CapEF: gallons EF:0.820 a.Slab-On-Grade Edge Insulation R=0.0 1280.00 ft2 b. Conservation features b.Floor over Garage R=13.0 388.00 ft' None c.other(see details) R= 304.00 ft' 15.Credits Pstat Total Proposed Modified Loads: 85.02 PASS Glass/Floor Area: 0.190 Total Baseline Loads: 87.85 I hereby certify that the plans and specifications covered by Review of the plans and ...O1THE STgT� this calculation are in compliance with the Florida Energy specifications covered by this v : ; ;;..•O4 Code. calculation indicates compliance Ic4I•�„`' , � . with the Florida Energy Code. i ti:...•, ", ,:-..- i-..4;;;..::•`--,%':0 PREPARED BY: Before construction is completed e 1 ..� t s t '-- a DATE: 04 06 16 Fdwin Rodriguez this building will be inspected for t 0',, _ _E_ compliance with Section 553.908 't ,. b'O Florida Statutes. %.f I hereby certify that this building,as designed, is in compliance .�1•`,oD��4v�..r� with the Florida Energy Code. ,,, OWNER/AGENT: BUILDING OFFICIAL: . /71)' -- DATE: DATE: R-510 ._____1 U - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and ane velofll�Vv3$a e test report in accordance with R402.4.1.2. c \'I"4/8/2016 5:15 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant SoftwarePage of 5 • FORM R405-2014 PROJECT Title: CoralSt Bedrooms: 4 Address Type: Street Address Building Type: User ConditionedArea: 3260 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: PILLAR CONSTRUCTION RotateAngle: 0 Street: CORAL STREET Permit Office: Duval Cross Ventilation: No County: Duval Jurisdiction: 261000 Whole House Fan: No City,State,Zip: , FamilyType: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer DegreeDays Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 3260 30644 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 3260 30644 Yes 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter PerimeterR-Value Area Joist R-Value Tile Wood Carpet - 1 Raised Floor Main ____ ____ 304 ft2 13 0.34 0 0.66 2 FlooroverGarage Main ____ ____ 388 ft2 13 0.42 0 0.58 3 Slab-On-GradeEdgelnsulation Main 141.5 ft 1280 ft2 ____ 0.37 0 0.63 ROOF VRoof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Compositionshingles 2214 ft2 0 ft2 Medium 0.85 N 0.85 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1980 ft2 N N 4/8/2016 5:15 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING v✓ # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 UnderAttic(Unvented) Main 0 1980 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Fraction Absor. Grade% 1 N Exterior Frame-Wood Main 19 69 7 10 0 695.8 ft2 0 0.25 0.6 0 _ 2 E Exterior Frame-Wood Main 19 118 2 10 0 1181.7 ft2 0 0.25 0.6 0 3 S Exterior Frame-Wood Main 19 52 1 10 0 520.8 ft' 0 0.25 0.6 0 _ 4 W Exterior Frame-Wood Main 19 104 2 10 0 1041.7 ft2 0 0.25 0.6 0 5 - Garage Frame-Wood Main 19 31 6 10 0 315.0 ft' 0 0.25 0.01 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area V Ft In Ft In 1 - Wood Main None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.35 0.29 14.2 ft2 1 ft 4 in 3 ft 4 in None None 2 N 1 Vinyl Low-E Double Yes 0.35 0.29 16.0 ft2 1 ft 6 in 1 ft 0 in None None 3 N 1 Vinyl Low-E Double Yes 0.35 0.29 16.5 ft2 1 ft 4 in 6 ft 0 in None None 4 N 1 Vinyl Low-EDouble Yes 0.35 0.29 16.5 ft2 1 ft 4 in 8 ft 3 in None None 5 N 1 Vinyl Low-E Double Yes 0.35 0.29 48.0 ft2 1 ft 6 in 2 ft 0 in None None 6 N 1 Vinyl Low-E Double Yes 0.35 0.29 21.0 ft2 15 ft 0 in 1 ft 0 in None None 7 N 1 Vinyl Low-E Double Yes 0.35 0.29 63.3 ft2 15 ft 0 in 1 ft 0 in None None 8 E 2 Vinyl Low-E Double Yes 0.35 0.29 9.0 ft2 1 ft 6 in 10 ft 0 in None None 9 E 2 Vinyl Low-E Double Yes 0.35 0.29 7.5 ft2 1 ft 4 in 0 ft 8 in None None 10 E 2 Vinyl Low-E Double Yes 0.35 0.29 8.0 ft2 1 ft 6 in 10 ft 0 in None None 11 E 2 Vinyl Low-E Double Yes 0.35 0.29 60.0 ft2 1 ft 4 in 0 ft 8 in None None 12 E 2 Vinyl Low-E Double Yes 0.35 0.29 16.5 ft2 1 ft 4 in 0 ft 8 in None None 13 E 2 Vinyl Low-EDouble Yes 0.35 0.29 36.0 ft2 1 ft 6 in 10 ft 0 in None None 14 S 3 Metal Low-E Double Yes 0.35 0.29 21.3 ft2 13 ft 0 in 1 ft 0 in None None 15 S 3 Vinyl Low-E Double Yes 0.35 0.29 20.2 ft2 1 ft 4 in 1 ft 0 in None None 16 S 3 Vinyl Low-E Double Yes 0.35 0.29 33.0 ft2 1 ft 4 in 6 ft 10 in None None 17 S 3 Vinyl Low-E Double Yes 0.35 0.29 36.0 ft2 9 ft 6 in 1 ft 0 in None None 18 S 3 Vinyl Low-E Double Yes 0.35 0.29 8.0 ft2 13 ft 0 in 1 ft 0 in None None 19 W 4 Metal Low-E Double Yes 0.35 0.29 21.3 ft' 3 ft 0 in 1 ft 8 in None None 20 W 4 Vinyl Low-E Double Yes 0.35 0.29 15.0 ft2 1 ft 4 in 0 ft 8 in None None 21 W 4 Vinyl Low-E Double Yes 0.35 0.29 18.0 ft2 1 ft 6 in 11 ft 8 in None None 22 W 4 Vinyl Low-E Double Yes 0.35 0.29 16.0 ft2 1 ft 4 in 1 ft 2 in None None 23 W 4 Vinyl Low-E Double Yes 0.35 0.29 11.6 ft2 1 ft 4 in 0 ft 8 in None None 24 W 4 Vinyl Low-E Double Yes 0.35 0.29 66.0 ft2 1 ft 4 in 0 ft 8 in None None 25 W 4 Vinyl Low-E Double Yes 0.35 0.29 21.0 ft2 1 ft 6 in 2 ft 0 in None None 4/8/2016 5:15 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE 1 # FloorArea CeilingArea Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation _ 1 388 ft2 384 ft2 48 ft 9.4 ft 3 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000299 2553.7 140.19 263.65 .2831 5 HEATING SYSTEM / # System Type Subtype Efficiency Capacity _Block Ducts 1 Electric Heat Pump Split HSPF:8.2 40 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:14.5 40 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.82 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert# CompanyName System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 652 w Attic 163 ft2 DefaultLeakage Main (Default)c(Default)c 1 1 4/8/2016 5:15 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: Coolin Jan Feb Mar A r Ma (X]Jun X Jul X Au [[X]gee,,,, [ ]Oct [ Nov Dec Heatinf Xj Jan f X]Feb f X]Mar k Apr l i Ma [ 1 Jun [ 'Jul l i Aug [ ] [ ]Oct [X'Nov Dec Venting [ Jan [ ]Feb X Mar Apr [ May [ ]Jun Jul [ Aug [[ ]Sep [X1 Oct [X'Nov nDec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 70 0 0 1-Electric Heat Pump % 1-Central Unit 4/8/2016 5:15 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED NERGY PERFORMANCE INDEX* = 97 The lower the En rgyPerformance Index, the more efficient the home. CORAL STREET, , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3440.00 ft2 b.Frame-Wood,Adjacent R=19.0 315.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Roof Deck(Unvented) R=20.0 1980.00 ft2 6. Conditioned floor area(ft2) 3260 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor. Dbl,U=0.35 620.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.29 a.Sup:Attic,Ret:Attic,AH:Main 6 652 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 40.0 SEER:14.50 SHGC: d. U-Factor. N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.318 ft. a.Electric Heat Pump 40.0 HSPF:8.20 Area Weighted Average SHGC: 0.290 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1280.00 ft2 a.Natural Gas Cap:1 gallons EF:0.82 b.Floor over Garage R=13.0 388.00 ft2 c.other(see details) R= 304.00 ft2 b.Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building 7' ;,,� Construction through the above energy saving features which will be installed (or exceeded) �e�oF,, HE4gTF ti,, in this home before final inspection. Otherwise, a new EPL Display Card will be completed ` y�3',, = ��', based on installed Code co_mptiant features. ;ti Nrr-.;• :i-i ° to • C7E Builder Signature, �_ _ - Date: �s/�6 ; LI ._0, it_ ,.. 2�,C, Address of New Home: ,ij 1,,,-,,/S,l, .d�-,( ` City/FL Zip: y. , y ,� . t ,yCv � rr '' OUWE11 � *Note: This is not a Building Energy Rati g. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain - Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web si a at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. I **Label required by Section R303.1.3 oft e Florida Building Code, Energy Conservation, if not DEFAULT. 4/8/2016 5:15 PM EnergyGaug USA-FlaRes2014-Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: CoralSt Builder Name: PILLAR CONSTRUCTION Street: CORAL STREET Permit Office: Duval City,State,Zip: ,FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261000 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA: EqLA: ACH: ACH(50): SLA: R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermalenvelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration controlmeasures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sea led; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code .,.:�0elliE TF::: performance results demonstrate compliance official, testing shall be conducted 04.,\. with Florida Energy Code requirements in by an approved third party. A ` ' accordance with Section R402.4.1.2. written report of the results of the A"1-1;; yo test shall be signed by the third 01, a.` party conducting the test and __ate _ SIGNATURE: provided to the code official. PRINTED NAME: . .et•OD WE. BUILDING OFFICIAL: DATE: DATE: 4/8/2016 5:15 PM EnergyGauge®USA-Fla Res2014 -Section R405.4.1 Compliant Software Page 1 of 1 • "4DEL-AIR Manual S Compliance Report Job: CORAL STREET Date: 03.23.16 HEATING AIR CONOmONING Entire House By: BENTLEY DEL AIR HEATING & AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-831-2665 Project Information For: PILLAR CONSTRUCTION CORAL STREET Cooling Equipment Design Conditions Outdoor design DB: 92.7°F Sensible gain: 31672 Btuh Entering coil DB: 76.1°F Outdoor design WB: 77.1°F Latent gain: 6667 Btuh Entering coil WB: 63.7°F Indoor design DB: 75.01= Total gain: 38339 Btuh Indoor RH: 50% Estimated airflow: 1333 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042""A+FV4CN(B,F)005L Actual airflow: 1333 cfm Sensible capacity: 31574 Btuh 100%of load Latent capacity: 7219 Btuh 108%of load Total capacity: 38793 Btuh 101%of load SHR: 81% Heating Equipment Design Conditions Outdoor design DB: 32.59= Heat loss: 38188 Btuh Entering coil DB: 67.89= Indoor design DB: 70.0°= Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042""A+FV4CN(B,F)005L Actual airflow: 1333 cfm Output capacity: 32318 Btuh 85%of load Capacity balance: 32 °F Supplemental heat required: 5870 Btuh Economic balance: -99 9= Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1333 cfm Output capacity: 5.2 kW 46%of load Temp. rise: 50 9= The above equipment was selected in accordance with ACCA Manual S. 2016-Apr-08 15:36:53 wrightsoft Right-Suite)Universal 2015 15.0.24 RSU24006 Page 1 ACCA ...s'\PillarConstructionJa,ACoralStreet CoralSt.rup Calc=MJ8 House faces: S QDEL-AIR Component Constructions Job: CORAL STREET Date: 03.23.16 Mina'wn col Qatar s Entire House By: BENTLEY DEL AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 32771 Phone:407-831-2665 Pro'ect Information For. PILLAR CONSTRUCTION CORAL STREET Design Conditions Location: Indoor: Heating Cooling Jacksonville Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 33 ft Design TD (°F) 38 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grub) 11.0 51.2 Dry bulb(°F) 33 93 Infiltration: Daily range(°F) - 18 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain 8" BuMt"-'F tr-'I uh BluhRt" Btuh Btuhitt' Btuh Walls 12E-Osw:Frm wall,stucco ext,r-19 cav ins,1/2"gypsum board int n 500 0.068 19.0 2.55 1276 1.43 718 fnsh,2"x4"wood frm,16"o.c.stud e 1045 0.068 19.0 2.55 2663 1.43 1499 s 403 0.068 19.0 2.55 1027 1.43 578 w 873 0.068 19.0 2.55 2225 1.43 1252 all 2820 0.068 19.0 2.55 7191 1.43 4046 Partitions 12E-Osw:Frm wall,r-19 cav ins,1/2"gypsum board int fnsh,2"x4" 297 0.068 19.0 2.55 758 0.86 257 wood frm,16"o.c.stud Windows 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 14 0.350 0 13.1 189 12.2 176 1/8"thk;NFRC rated(SHGC�.29);1.3 ft overhang(2.7 ft window ht, 3.3 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,dr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 16 0.350 0 13.1 210 12.2 195 1/8"thk;NFRC rated(SHGC=0.29);1.5 ft overhang(4 ft window ht,1 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 17 0.350 0 13.1 217 12.2 201 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(5.5 ft window ht,6 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 17 0.350 0 13.1 217 12.2 201 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(5.5 ft window ht, 8.25 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 48 0.350 0 13.1 630 12.2 586 1/8"thk;NFRC rated(SHGCO.29);1.5 ft overhang(6 ft window ht,2 ft w 21 0.350 0 13.1 276 34.0 714 sep.);6.67 ft head ht all 69 0.350 0 13.1 906 18.8 1300 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr iow-e innr,1/4"gap, n 21 0.350 0 13.1 276 12.2 256 1/8"thk;NFRC rated(SHGC=0.29);15 ft overhang(6 ft window ht,1 ft sep.);6.67 ft head ht 2A-2ovd:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, n 63 0.350 0 13.1 831 12.2 773 1/8"thk;NFRC rated(SHGC=.29);15 ft overhang(8 ft window ht,1 ft sep.);6.67 ft head ht 2016-Apr-08 15:36:53 •C Ad" wrightsot Right-Suite®universal 2015 15.0.24 RSU24006 Page 1 ...s\PillarConstructionJax\CoralStreet\CoralSt.rup Cab=MJ8 House taces: S 2A-2ov:2 glazing,dr outr,air gas,vni frm mat,clr low-e innr,1/4"gap, e 9 0.350 0 13.1 118 34.0 306 1/8"thk;NFRC rated(SHGCO.29);1.5 ft overhang(1.5 ft window ht, 10 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,dr outr,air gas,vni frm mat,clr low-e innr,1/4"gap, e 8 0.350 0 13.1 98 31.0 233 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(3 ft window ht, w 15 0.350 0 13.1 197 31.0 466 0.67 ft sep.);6.67 ft head ht all 23 0.350 0 13.1 295 31.0 698 2A-2ov:2 glazing,dr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, e 8 0.350 0 13.1 105 34.0 272 1/8"thk;NFRC rated(SHGC=0.29);1.5 ft overhang(3 ft window ht,10 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, e 60 0.350 0 13.1 788 32.2 1934 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(5 ft window ht, 0.67 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,dr outr,air gas,vnl frm mat,dr low-e innr,1/4"gap, e 17 0.350 0 13.1 217 32.4 534 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(5.5 ft window ht, w 66 0.350 0 13.1 866 32.4 2138 0.67 ft sep.);6.67 ft head ht all 83 0.350 0 13.1 1083 32.4 2672 2A-2ov:2 glazing,clr outr,air gas,vni frm mat,clr low-e innr,1/4"gap, e 36 0.350 0 13.1 473 34.0 1224 1/8"thk;NFRC rated(SHGC=0.29);1.5 ft overhang(6 ft window ht,10 ft sep.);6.67 ft head ht 10C-m:2 glazing,clr outr,air gas,mtl no brk frm mat,cir low-e innr,1/4" s 21 0.350 0 13.1 280 8.55 182 gap,1/8"thk;NFRC rated(SHGC�.29);13 ft overhang(8 ft window ht, 1 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,dr iow-e innr,1/4"gap, s 20 0.350 0 13.1 263 12.2 245 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(4.3 ft window ht,1 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,ch outr,air gas,vnl frm mat,ck low-e innr,1/4"gap, s 33 0.350 0 13.1 433 14.4 475 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(5.5 ft window ht, 6.83 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,dr outr,air gas,vni frm mat,clr low-e innr,1/4"gap, s 36 0.350 0 13.1 473 12.2 440 1/8"thk;NFRC rated(SHGC=0.29);9.5 ft overhang(6 ft window ht,1 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,dr low-e innr,1/4"gap, s 8 0.350 0 13.1 105 12.2 98 1/8"thk;NFRC rated(SHGC=0.29);13 ft overhang(8 ft window ht,1 ft sep.);6.67 ft head ht 10C-m:2 glazing,cir outr,air gas,mti no brk frm mat,ck low-e innr,1/4" w 21 0.350 0 13.1 280 22.2 474 gap,1/8"thk;NFRC rated(SHGC=.29);3 ft overhang(8 ft window ht, 1.67 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, w 18 0.350 0 13.1 236 34.0 612 1/8"thk;NFRC rated(SHGC4).29);1.5 ft overhang(3 ft window ht, 11.67 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, w 16 0.350 0 13.1 210 34.0 544 1/8"thk;NFRC rated(SHGC=.29);1.3 ft overhang(4 ft window ht, 1.17 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,dr outr,air gas,vnl frm mat,clr lon-e innr,1/4'gap, w 11 0.350 0 13.1 151 31.9 366 1/8"thk;NFRC rated(SHGC1.29);1.3 ft overhang(4.3 ft window ht, 0.67 ft sep.);6.67 ft head ht Doors 11 D0:Door,wd sc type n 18 0.390 0 14.6 261 11.8 210 Ceilings 16X19-0ad:Attic ceiling,asphalt shingles roof mat,r-20 roof ins,1/2' 2031 0.408 19.0 2.12 4312 1.57 3185 gypsum board int fnsh Floors 20P-13c:Fir floor,frm flr,6"thkns,carpet flr fnsh,r-13 cav ins,amb ow 304 0.068 13.0 2.55 775 0.93 283 20P-13c:Fir floor,frm flr,6"thins,carpet flr fnsh,r-13 cav ins,gar ow 399 0.068 13.0 2.55 1017 0.93 372 22A cpl:Bg floor,light dry soil,on grade depth,carpet flr fnsh 142 0.989 0 37.1 5248 0 0 2016-Apr-08 15:36:53 .4 � wrightsoft" Right-Suite®Universal 2015 15.0.24 RSU24006 Page 2 ..slPillarConstructionJax\CoralStreet\CoralSt.rup Calc=MJ8 House faces: S d ,(I iDEL-AIR ProjectSummary Job: CORAL STREET Date: 03.23.16 .HERTING AIR CONDITIONING Entire House By: BENTLEY DEL AIR HEATING & AIR CONDITIONING 531 CODISCO WAY.SANFORD,FL 32771 Phone:407-831-2665 Pro'ect Information For: PILLAR CONSTRUCTION CORAL STREET Notes: 04.08.16 ER Desi• n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 51 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 33116 Btuh Structure 28699 Btuh Ducts 2188 Btuh Ducts 1612 Btuh Central vent (70 cfm) 2884 Btuh Central vent (70 cfm) 1361 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 38188 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load (31672 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3175 Btuh Ducts 1060 Btuh Heating Cooling Central vent (70 cfm) 2432 Btuh Area(ft2) 3260 3260 Equipment latent load ... Btuh Volume(ft3) 31554 31554 Air changes/hour 0.25 0.13 Equipment total load8339 Btuh Equiv. AVF (cfm) 131 68 Req. total capacity at 0.75 SHR ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB042****A Gond CH14NB042****A AHRI ref 7835752 Coil FV4CN(B,F)005L AHRI ref 7835752 Efficiency 8.2 HSPF Efficiency 12.0 EER, 14.5 SEER Heating input Sensible cooling 30000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 10000 Btuh Temperature rise 28 °F Total cooling 40000 Btuh Actual air flow 1333 cfm Actual air flow 1333 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.40 in H2O Static pressure 0.40 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 0 2016-Apr-08 15:36:53 ± wrightsoft Right-Suitee Universal 2015 15.0.24 RSU24006 Page 1 AC.c.P. ...s'PillarConstructionJax\CoralStreel\CoraiSI.rup Calc=MJ8 House faces: S I ,DEL--AIR Right-J®Worksheet Job: CORAL STREET f .nunNs MRCOKOMONING Date: 03.23.16 Entire House By: BENTLEY DEL AIR HEATING &AIR COITIONG 531 CODISCO WAY,SANFORD,FL 32771 N�40i 831-2665 1 Room name Entire House DINING 2 Eaposed wall 366.5 ft 32.5 ft 3 Room height 9.4 ft 10.0 ft heat/cool 4 Room dimensions 8.5 x 15.5 ft 5 Room area 3358.5 ft' 131.8 ft' Ty Construction U-value Or HTM Area (It') Load Area (ft') Load number (Btuhift'-`F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 2.55 1.43 696 500 1276 718 155 71 180 101 . 2A-2ov 0.350 n 13.13 12.21 14 0 189 176 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 16 0 210 195 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 17 0 217 201 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 17 0 217 201 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 48 0 630 586 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 21 0 276 256 21 0 276 256 2A-2ovd 0.350 n 13.13 12.21 63 0 831 773 63 0 831 773 12E-Osw 0.068 e 2.55 1.43 1182 1045 2663 1499 85 85 217 122 2A-2ov 0.350 e 13.13 34.01 9 0 118 306 0 0 0 0 2A-2ov 0.350 c 13.13 31.04 8 1 98 233 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 8 0 105 272 0 0 0 0 2A-2ov 0.350 e 13.13 32.23 60 5 788 1934 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 17 1 217 534 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 36 0 473 1224 0 0 0 0 12E-Osw 0.068 s 2.55 1.43 521 403 1027 578 0 0 0 0 1C m 0.350 s 13.13 8.55 21 21 280 182 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 20 20 263 245 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 33 1 433 475 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 36 36 473 440 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 8 8 105 98 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 1042 873 2225 1252 85 64 163 92 10C-m 0.350 w 13.13 22.24 21 2 280 474 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 15 2 197 466 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 18 0 236 612 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 16 0 210 544 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 11 1 150 366 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 66 5 866 2138 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 21 0 276 714 21 0 276 714 112E-Osw 0.068 - 2.55 0.86 315 297 758 257 0 0 0 0 D 11D0 0.390 n 14.62 11.78 18 18 261 210 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 2031 2031 4312 3185 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 304 304 775 283 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 399 399 1017 372 0 0 0 0 F 22A-cp1 0.989 - 37.09 0.00 1328 142 5248 0 132 33 1205 0 6 c)AED excursion 0 9 Envelope loss/gain 27699 21999 3148 2068 12 a) Infiltration 5417 1330 512 126 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 4450 0 Subtotal(lines 6 to 13) 33116 28699 3660 2193 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 33116 28699 3660 2193 15 Duct loads 7% 6% 2188 1612 -0% 0^/ 0 0 Total room load 35304 30311 3660 2193 Air required(cfm) 1333 1333 138 96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w r ig h tsoft 2016-Apr-08 15:36:53 AC"‘ Right-Suite®Universal 2015 15.0.24 RSU24006 Page 1 ...s.PillarConstructionJax1CoralStreet\Cor alSt.rup Calc=MJ8 House faces: S 3DEL-AIR Right-J® Worksheet Job: CORAL STREET HEATING AIR coloommis Entire House Date: 03.23.16 By: BENTLEY DEL AIR HEATING &AIR 531 CODISCO WAY,SANFORD,FL 3277CONDITIONING 66 1 Room name KITCHEN PANTRY 2 Exposed wall 18.5 ft 5.5 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cod 4 Room dimensions 18.5 x 15.5 ft 5.5 x 10.0 ft 5 Room area 286.8 ft2 55.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/t12-`F) (Btuh'ft2) ix perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 W 12E-Osw 0.068 n 2.55 1.43 0 0 0 0 0 0 0 0 . G 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-20v 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 -C 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 G 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 1 12E-Osw 0.068 e 2.55 1.43 185 176 449 253 55 55 140 79 2A-2ov 0.350 e 13.13 34.01 9 0 118 306 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.23 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 112E Osw 0.068 s 2.55 1.43 0 0 0 0 0 0 0 0 14-m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 • 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 0 0 0 0 F 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 I 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 0 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 22A-cp1 0.989 - 37.09 0.00 287 19 686 0 55 6 204 0 6 c)AED excursion -56 -4 Envelope loss/gain 1253 503 344 75 12 a) Infiltration 291 72 87 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1800 0 Subtotal(lines 6 to 13) 1544 2374 431 96 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1544 2374 431 96 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 1544 2374 431 96 Ar required(cfm) 58 104 16 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +1+ wrightsoft 2016-Apr-08 15:36:53 .A� Right-Suite®Universal 2015 15.0.24 RSU24006 Page 2 ...sPillarConstructionJax\CoralStreet`,CoratSt.mp Calc=MJ8 House faces: S DEL-AIR Right-J®Worksheet Job: CORAL STREET HEATING AIN CONOnwNING Entire House Date: 03.23.16 By: BENTLEY CDEEL AIRRT HEATINGN &AIR 531 CODISCO WAY.SANFORD,FL 32771 Phon�e:D 07 831-2665 G 1 Room name BATH OFFICE/GUEST 2 E1posed wall 6.0 ft 24.5 ft 3 Room height 10.0 ft heat/cod 10.0 ft heat/cool 4 Room dimensions 6.0 x 10.0 ft 13.5 x 10.0 ft 5 Room area 60.0 ft' 135.0 ft' Ty Construction U-value Or HTM Area MI Load Area (ft/ Load number (&uh/ft'--F) (Btuh/11') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 2.55 1.43 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 2.55 1.43 60 52 133 75 135 99 252 142 2A-2ov 0.350 c 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 8 0 105 272 0 0 0 0 2A-2ov 0.350 c 13.13 32.23 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 36 0 473 1224 12E-Osw 0.068 s 2.55 1.43 0 0 0 0 100 64 163 92 t OC m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 A-2ov 2 G0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 36 36 473 440 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 10 10 26 14 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 o 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 22A-cpl 0.989 - 37.09 0.00 60 6 223 0 135 25 909 0 6 c)AED excursion 21 -103 Envelope loss/gain 460 368 2295 1809 12 a) Infiltration 94 23 386 95 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 600 Subtotal(lines 6 to 13) 555 391 2681 2504 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 555 391 2681 2504 15 Duct loads -0"/ 0% 0 0 -0% 0"/ 0 0 Total room load 555 391 2681 2504 Air required(cfm) 21 17 101 110 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WI'Igf7t50fC 2016-Apr-0815:36:53 ACCP 414- Right-Suite®Universal 2015 15.0.24 RSU24006 Page 3 ...s.PillarConstructionJax1CoralStreet\CoralSt.rup Calc=MJ8 House laces: S DEL--AIR Right-J®Worksheet Job: CORAL STREETt MUM•"""""" Entire House Date: 03.23.16 By: BENTLEY DEL AIR HEATING &AIR ONG 531 CODISCO WAY.SANFORD,FL 32771 Phone:4OT/831 -2665 1 Room name GREAT RM MUD RM 2 Exposed wall 45.0 ft 9.5 ft 3 Room height 10.0 ft heat/cod 10.0 ft heat/cool 4 Room dimensions 1.0 x 569.0 ft 9.5 x 9.5 ft 5 Room area 569.0 ft2 90.3 ft2 Ty Construction I U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/It'-`F) (Btuhrft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P,'S Heat Cool 6 12E-0sw 0.068 n 2.55 1.43 190 142 362 204 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 48 0 630 586 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 NJ 12E-Osw 0.068 e 2.55 1.43 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 e 13.13 32.23 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 12E-05w 0.068 s 2.55 1.43 70 41 104 58 0 0 0 0 10C-m 0.350 s 13.13 8.55 21 21 280 182 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 8 8 105 98 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 190 172 439 247 95 74 188 106 10C-m 0.350 w 13.13 22.24 0 0 0 0 21 2 280 474 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 18 0 236 612 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 I 12E-Osw 0.068 - 2.55 0.86 220 202 515 175 95 95 242 82 p 1 D 1100 0.390 n 14.62 11.78 18 18 261 210 0 0 0 0 C 16X19-Oad 0.408 - 2.12 1.57 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 22A-cpl 0.989 - 37.09 0.00 569 45 1669 0 90 10 352 0 6 c)AED excursion -43 223 Envelope loss/gain 4601 2329 1062 885 12 a) Infiltration 709 174 150 37 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 5310 3193 1212 922 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5310 3193 1212 922 15 Duct loads -0% 0% 0 0 -0°% 0% 0 0 Total room load 5310 3193 1212 922 Air required(cfm) 200 140 46 41 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AZ- wrightsoft 2016-Apr-08 15:36:53 Right-Suite®Universal 2015 15.0.24 RSU24006 Page 4 ...s\PillarConsfructionJax\CoralStreet\CoralSLrup Calc=MJ8 House faces: S /DEL--AIR Right-J® Worksheet Job: CORAL STREET .HEATING ANI COBOngNING Entire House Date: 012316 By: BENTLEY DEL AIR HEATING &AIR NG 531 CODISCO WAY.SANFORD,FL 3277�f ND4�I N665 1 Room name BED 3 BED 3 WIC 2 Exposed wall 27.5 ft 8.0 ft 3 Room height 9.0 ft heat/cod 9.0 ft heat/cool 4 Room Eimensions 12.5 x 15.0 ft 6.5 x 6.0 ft 5 Room area 187.5 ft' 39.0 ft' Ty Construction U-value Or HTM Area (f1') Load Area (f t') Load number (Btuh'ft'-`F) (Btuhtt') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 2.55 1.43 135 102 260 146 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 17 0 217 201 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 17 0 217 201 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 2.55 1.43 0 0 0 0 0 0 0 0 2A-2ov 0.350 c 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 a 13.13 32.23 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 2.55 1.43 0 0 0 0 14 14 34 19 -G 10C-m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 -(.5 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 113 96 245 138 59 59 149 84 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 17 1 217 534 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 11 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 188 188 398 294 39 39 83 61 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 22A-cpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 116 -8 Envelope loss/gain 1553 1631 266 157 12 a) Infiltration 390 96 113 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1942 1727 380 185 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1942 1727 380 185 15 Duct loads 12% 9% 240 163 12% 9% 47 17 Total room load 2182 1890 427 202 Air required(cfm) 82 83 16 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. am rig htsoft 2016-Apr-08 15:36:53 "E-6P. Right-Suitt'®Universal 2015 15.0.24 RSU24006 Page 5 ...siPillarConsiructionJax\CoralStreef,CoralS1.rup Calc-MJ8 House laces: S -;DEL-AIR Right-J®Worksheet Job: CORAL STREET ,Hum AIN CONDITIONING Entire House Date: 03.23.16 By: BENTLEY DEL AIR HEATING &AIR C1 NDII G 531 CODISCO WAY,SANFORD,FL 3277 one:40i-83i-2665NI 1 Room name BATH 3 MASTER SUITE 2 Exposed wall 0 ft 28.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.5 x 9.0 ft 1.0 x 280.0 ft 5 Room area 58.5 ft' 280.0 ft- Ty Construction U-value Or HTM Area (III Load Area (f t2) Load number (Btuh'ft'-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 2.55 1.43 0 0 0 0 36 36 92 52 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-20v 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 2.55 1.43 0 0 0 0 144 114 291 164 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.23 0 0 0 0 30 2 394 967 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 12E-Osw 0.068 s 2.55 1.43 0 0 0 0 0 0 0 0 11,X;-m 0.350 s 13.13 855 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 72 39 99 56 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 33 2 433 1069 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 I 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 I D 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 59 59 124 92 280 280 595 439 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 22A-opt 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -4 -106 Envelope loss/gain 124 88 1903 2640 12 a) Infiltration 0 0 397 97 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 850 Subtotal(lines 6 to 13) 124 88 2300 3818 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 124 88 2300 3818 15 Duct loads 12'/ 9'/ 15 8 12% 9% 284 361 Total room load 140 96 2584 4179 Air required(cfm) 5 4 98 184 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightso - 2016-Apr-08 15:36:53 . EA Right-Suite®Universal 2015 15.0.24 RSU24006 Page 6 ...s'PillarConstructionJax\CoralStreeP.CoralSt.rup Calc=MJ8 House faces: S ,DEL--AIR Rig ht-J® Worksheet Job: CORAL STREET mune URCormnwRrRC Entire House Date: 03.23.16 By: BENTLEY DEL AIR HEATING &AIR 531 CODISCO WAY.SANFORD,FL 32771�N�4007 8(31-26665 1 Room name MASTER BATH MASTER W.0 2 Exposed wall 32.5 ft 10.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 171.8 ft 6.0 x 4.0 ft 5 Room area 171.8 ft' 24.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh'ft'-`f) (Btuh/ft') or perimeter (ft( (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 • 12E-Osw 0.068 n 2.55 1.43 104 80 205 115 36 29 73 41 2A-2ov 0.350 n 13.13 12.21 7 0 95 88 7 0 95 88 2A-2ov 0.350 n 13.13 12.21 16 0 210 195 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 2.55 1.43 122 114 291 164 0 0 0 0 2A-2ov 0.350 c 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 8 1 98 233 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 c 13.13 32.23 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 12E-Osw 0.068 s 2.55 1.43 0 0 0 0 0 0 0 0 10C-m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 a 13.13 14.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 • 12E-Osw 0.068 w 2.55 1.43 68 60 153 86 54 47 119 67 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 8 1 98 233 8 1 98 233 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 R 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 D 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 172 172 365 269 24 24 51 38 F 20P-13c 0.068 - 2.55 0.93 164 164 418 153 24 24 61 22 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 22A-cpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -65 87 Envelope loss/gain 1933 1470 497 576 12 a) Infiltration 461 113 142 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2393 1584 639 611 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2393 1584 639 611 15 Duct loads 12% 9% 295 150 12% 9% 79 58 Total room load 2689 1733 718 669 Air required(cfm) 102 76 27 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w r ig h is o ft 2016-Apr-08 15:36:53 RCCA Right-Suite®Universal 2015 15.0.24 RSU24006 Page 7 ...s`PillarConstructionJax\CoralStreer,CoralSt.rup Calc=MJ8 House faces: S ;DEL-AIR Right-J®Worksheet Job: CORAL STREET .IEATIRC AIRCONOn10RIRG Entire House Date: 03.23.16 By: BENTLEY DEL AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 3277 one:40 831 2665 1 Room name MASTER WIC GATHERING 2 E posed wall 11.0 ft 26.5 ft 3 Room height 9.0 ft heat/cod 9.0 ft heat/cod 4 Room dimensions 11.0 x 15.5 ft 1.0 x 428.0 ft 5 Room area 170.5 ft' 428.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-`f) (Btuh/ft,) or perimeter (ft) (Btuh) or perimeter (ft) (Bfuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 2.55 1.43 0 0 0 0 14 14 34 19 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 VI 12E-Osw 0.068 e 2.55 1.43 99 99 252 142 140 110 279 157 G 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 -C 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 e 13.13 32.23 0 0 0 0 30 2 394 967 -C 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 12E-Osw 0.068 s 2.55 1.43 0 0 0 0 14 14 34 19 10C m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 72 56 143 80 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 16 0 210 544 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 IR 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 D 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 171 171 362 267 428 428 909 671 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 23 23 59 22 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 16 16 41 15 F 22A-cpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -18 -126 Envelope loss/gain 614 392 2104 2369 12 a) Int iltration 156 38 376 92 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 600 Subtotal(lines 6 to 13) 770 430 2479 3061 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 770 430 2479 3061 15 Duct loads 12% 9% 95 41 12"/ 9% 306 290 Total room load 865 471 2785 3351 Air required(cfm) 33 21 105 147 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wrightsoTt 2016-Apr-08 15:36:53 ACCA Right-Suite®Universal 2015 15.0.24 RSU24006 Page 8 ...s,PiltarConstructionJax\CoralSireet`.CoralSt.rup Calc-MJ8 House faces: S DEL--AIR Rig ht-J®Worksheet Job: CORAL STREET HEATING .M`O"°'T'°"'"° Entire House Date: 03.23.16 By: BENTLEY DEL AIR HEATING &AIR CONDITIONING 531 CODISCO WAY,SANFORD,FL 3277 one:40 891-2665 2665 1 Room name BED 2 WIC BED 2 2 Exposed wall 0 ft 29.0 ft 3 Room height 9.0 ft heat/cod 9.0 ft heat/cod 4 Room dimensions 5.5 x 5.5 ft 1.0 x 177.8 ft 5 Room area 30.3 ft' 177.8 ft' Ty Construction L1-value Or HTM Area (ftl Load Area (ft') Load number (Btufvft'-`F) (Btuh/tF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 • 12E-Osw 0.068 n 2.55 1.43 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 2.55 1.43 0 0 0 0 122 105 268 151 2A-2ov 0.350 0 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.23 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 17 1 217 534 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 VJ 12E-Osw 0.068 s 2.55 1.43 0 0 0 0 126 106 270 152 -G 10C-m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 20 20 263 245 -G 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 VI 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 14 14 34 19 G 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 -----G 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 G 2A-20v 0.350 w 13.13 32.39 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 D 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 30 30 64 47 178 178 377 279 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 56 56 142 52 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 0 0 0 0 F 22A-cpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -2 -61 Envelope loss/gain 64 46 1572 1371 12 a) Infiltration 0 0 411 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 64 46 1983 1472 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 64 46 1983 1472 15 Duct loads 12% 9% 8 4 12% 9"/ 245 139 Total room load 72 50 2228 1612 Air required(cfm) 3 2 84 71 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -+/- wrigtitsoft 2016-Apr-08 15:36:53 ACOA Right-Suite®Universal 2015 15.0.24 RSU24006 Page 9 ...s.PillarConstructionJax\CoralSireet\CoralSt.rup Calc-Ma House faces: S ,DEL-AIR Right-J®Worksheet Job: CORAL STREET MATING ANSCONOmONWGEntire House Date: 0123.16 By: BENTLEY DEL AIR HEATING &AIR NG 531 CODISCO WAY,SANFORD,FL 32771 Phone I�I N665 1 Room name BATH 2 BATH 2 W.C. 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cod 4 Room dimensions 14.5 x 7.5 ft 3.5 x 7.5 ft 5 Room area 108.8 ft2 26.3 ft' Ty Construction U-value Or HTM Area (f12) Load Area (ft2) Load number (Btuh/fiz°F) (Btufv'ft2) or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 2.55 1.43 0 0 0 0 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 • 12E-Osw 0.068 e 2.55 1.43 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.23 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 12E-Osw 0.068 5 2.55 1.43 0 0 0 0 0 0 0 0 10C-m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 R 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 D t D 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 109 109 231 171 26 26 56 41 F 20P-13c 0.068 - 2.55 0.93 0 0 0 0 4 4 10 3 F 20P-13c 0.068 - 2.55 0.93 78 78 199 73 21 21 54 20 F 22A-cpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -10 -3 Envelope loss/gain 430 234 119 62 12 a) Miltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 610 13) 430 234 119 62 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 430 234 119 62 15 Duct loads 12% 9`/ 53 22 12% 9% 15 6 Total room load 483 256 134 68 Air required(cfm) 18 11 5 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A wrightsoft 2016-Apr-08 15:36:53 Right-Suited Universal 2015 15.0.24 RSU24006 Page 10 Jax\ ...s\PillarConstructionCoralStreet`CoralSt.rup Calc-MJ8 House faces: S DEL-AIR Right-J®Worksheet Job: CORAL STREET .HEATING MN CONDITIONING Entire House Date: 03.23.16 By: BENTLEY DEL AIR HEATING &AIR 531 CODISCO WAY.SANFORD,FL 32771 Phone: 071831N565 G 1 Room name BED 1 WIC BED 1 2 Evosed wall 11.5 ft 27.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 35.3 ft 1.0 x 198.0 ft 5 Room area 35.3 ft' 198.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/ft'--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12E-Osw 0.068 n 2.55 1.43 0 0 0 0 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 . 26-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 0 0 0 0 V./ 12E-Osw 0.068 e 2.55 1.43 36 36 92 52 0 0 0 0 G 2A-2ov 0.350 c 13.13 34.01 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 a 13.13 32.23 0 0 0 0 0 0 0 0 -G 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 0 0 0 0 G 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 0 0 0 0 12E-Osw 0.068 s 2.55 1.43 68 68 172 97 117 84 214 121 t OC m 0.350 s 13.13 8.55 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 33 1 433 475 2A-2ov 0.350 s 13.13 12.21 0 0 0 0117 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 0 0 0 0 • 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 126 110 279 157 10C-m 0.350 w 13.13 22.24 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 0 0 0 0 0 0 0 0 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 17 1 217 534 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 0 0 0 0 R 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 0 0 0 0 D 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 35 35 75 55 198 198 420 311 F 20P-13c 0.068 - 2.55 0.93 8 8 21 8 13 13 33 12 F 20P-13c 0.068 - 2.55 0.93 27 27 69 25 185 185 472 172 F 22A-cp1 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -11 27 Envelope loss/gain 429 226 2068 1809 12 a) Infiltration 163 40 383 94 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 AppliancesJother 0 0 Subtotal(lines 6 to 13) 592 266 2451 1903 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 592 266 2451 1903 15 Duct loads 12% 9% 73 25 12'/ 9% 303 180 Total room load 665 291 2754 2083 Ar required(elm) 25 13 104 92 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w r igh tsafit 2016-Apr-08 15:36:53 AGS GP. Right-Suited Universal 2015 15.0.24 RSU24006 Page 11 ...s.PillarConstruclionJaxACoralStreet`CoralSt.rup Calc=MJ8 House faces: S ":,DEL-AIR Right-J®Worksheet Job: CORAL STREET NfAnNs MR CONOIr10NrNs Date: 03.23.16 Entire House By: BENTLEY DEL AIR HEATING &AIR NG 531 CODISCO WAY,SANFORD,FL 32771 NDI�I Nw166b 1 Room name LAUNDRY 2 Exposed wall 14.0 ft 3 Room height 9.0 ft heat/cool 4 Room dmensions 1.0 x 95.3 It 5 Room area 95.3 tt' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ttz°F) (Btuhitt') or perimeter (tt) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N./RS Heat Cod 6 12E-Osw 0.068 n 2.55 1.43 27 27 69 39 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 . 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 11 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 2A-2ov 0.350 n 13.13 12.21 0 0 0 0 2A-2ovd 0.350 n 13.13 12.21 0 0 0 0 12E-Osw 0.068 e 2.55 1.43 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 2A-2ov 0.350 e 13.13 31.04 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 2A-2ov 0.350 e 13.13 32.23 0 0 0 0 2A-2ov 0.350 e 13.13 32.39 0 0 0 0 2A-2ov 0.350 e 13.13 34.01 0 0 0 0 12E-Osw 0.068 s 2.55 1.43 14 14 34 19 1OC-m 0.350 s 13.13 8.55 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 2A-2ov 0.350 s 13.13 14.39 0 0 0 0 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 G 2A-2ov 0.350 s 13.13 12.21 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 86 74 189 106 10C-m 0.350 w 13.13 22.24 0 0 0 0 2A-2ov 0.350 w 13.13 31.04 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 2A-2ov 0.350 w 13.13 31.94 11 1 150 366 2A-2ov 0.350 w 13.13 32.39 0 0 0 0 2A-2ov 0.350 w 13.13 34.01 0 0 0 0 12E-Osw 0.068 - 2.55 0.86 0 0 0 0 D 11D0 0.390 n 14.62 11.78 0 0 0 0 C 16X19-0ad 0.408 - 2.12 1.57 95 95 202 149 F 20P-13c 0.068 - 2.55 0.93 12 12 31 11 F 20P-13c 0.068 - 2.55 0.93 72 72 184 67 F 22A-cpl 0.989 - 37.09 0.00 0 0 0 0 6 c)AED excursion 135 Envelope loss/gain 859 893 12 a) Infiltration 198 49 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 600 Subtotal(lines 6 to 13) 1057 1542 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1057 1542 15 Duct loads 12% 9"/ 131 146 Total room load 1188 1688 Air required(cfm) 45 74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -+ wrightsoft A2016-Apr-08 15:36:53 Right-Suited Universal 2015 15.0.24 RSU24006 Pagc 12 ...s\PiltarConstmctionjax\CoralStreet CoralSt.rup Calc=MJ8 House faces: S .' ,,DEL-AIR Duct System Summary Job: CORAL STREET Date: 03.23.16 J .HEATING AIR CONDITIONING Entire House By: BENTLEY DEL AIR HEATING & AIR CONDITIONING 531 CODISCO WAY,SANFORD.FL 32771 Phone:407-831-2665 Project Information For: PILLAR CONSTRUCTION CORAL STREET Heating Cooling External static pressure 0.40 in H2O 0.40 in H2O Pressure losses 0.06 in H2O 0.06 in H2O Available static pressure 0.34 in H2O 0.34 in H2O Supply! return available pressure 0.170/0.170 in H2O 0.170!0.170 in H2O Lowest friction rate 0.215 in/100ft 0.215 in/100ft Actual air flow 1333 cfm 1333 cfm Total effective length (TEL) 158 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH h 555 21 17 0.219 4.0 Ox 0 VIFx 45.1 110.0 st3 BATH 2 h 483 18 11 0.279 4.0 Ox 0 VIFx 22.1 100.0 st4 BATH 2 W.C. h 134 5 3 0.267 4.0 Ox 0 VIFx 27.2 100.0 st4 BATH 3 h 140 5 4 0.344 4.0 Ox 0 VIFx 13.7 85.0 st2 BED 1 .h 2754 104 92 0.309 6.0 Ox 0 VIFx 24.9 85.0 st2 BED 1 WIC h 665 25 13 0.265 4.0 Ox 0 VIFx 28.2 100.0 st4 BED 2 h 2228 84 71 0.268 6.0 Ox 0 VIFx 27.0 100.0 st4 BED 2 WIC h 72 3 2 0.274 4.0 Ox 0 VIFx 23.9 100.0 st4 BED 3 c 1890 82 83 0.316 6.0 Ox 0 VIFx 22.6 85.0 st2 BED 3 WIC h 427 16 9 0.329 4.0 Ox 0 VIFx 18.4 85.0 st2 DINING h 3660 138 96 0.248 7.0 Ox 0 VIFx 42.1 95.0 st1 GATHERING c 3351 105 147 0.330 7.0 Ox 0 VIFx 18.0 85.0 st2 GREAT RM h 2655 100 70 0.260 6.0 Ox 0 VIFx 35.6 95.0 st1 GREAT RM-A h 2655 100 70 0.272 6.0 Ox 0 VIFx 30.0 95.0 st1 KITCHEN c 2374 58 104 0.269 6.0 Ox 0 VIFx 31.3 95.0 st1 LAUNDRY c 1688 45 74 0.334 5.0 Ox 0 VIFx 16.8 85.0 st2 MASTER BATH h 2689 102 76 0.234 6.0 Ox 0 VIFx 45.5 100.0 st5 MASTER SUITE c 4179 98 184 0.258 7.0 Ox 0 VIFx 31.7 100.0 st5 MASTER W.0 c 669 27 29 0.230 4.0 Ox 0 VIFx 48.1 100.0 st5 MASTER WIC h 865 33 21 0.263 4.0 Ox 0 VIFx 29.3 100.0 st5 MUD RM h 1212 46 41 0.241 4.0 Ox 0 VIFx 45.8 95.0 st1 OFFICE/GUEST c 2504 101 110 0.215 6.0 Ox 0 VIFx 48.0 110.0 st3 PANTRY h 431 16 4 0.218 4.0 Ox 0 VIFx 45.9 110.0 st3 2016-Apr-08 15:36:54 ACCP -+- wrightsoft Right-Suite®Universal 2015 15.0.24 RSU24006 Page 1 ..s 1PillarConstructionJaACoralStreet\CoraISt.rup Calc=MJ8 House laces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 138 132 0.215 518 7.0 0 x 0 VinIFIx st1 st1 Peak AVF 581 513 0.215 544 14.0 0 x 0 VinIFIx st4 Peak AVF 135 100 0.265 506 7.0 0 x 0 VinlFlx st2 st5 Peak AVF 259 310 0.230 702 9.0 0 x 0 VinIFIx st2 st2 Peak AVF 752 820 0.230 587 16.0 0 x 0 VinIFIx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 1333 1333 0 0 0 0 Ox 0 VIFx 2016-Apr-08 15:36:54 wrightsoft Right-Suite®Universal 2015 15.0.24 RSU24006 Page 2 ACCA ..s\PillarConstructionJax\CoralStreet\CoralSt.rup Calc=WS House faces: S FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: CORAL STREET Permit Number: ,FL, MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law[Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. o R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1.as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed.beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shalt be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. o R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. o R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2).when tested according to NFRC 400 or AAMA/W DMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. o R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. U R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. U R403.1.3 Heat pump supplementary heat(Mandatory)Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost.prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory#,ll ducts,air handlers.and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 4/8/2016 10:56 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compli Page 1 of 3 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,dr low-e innr,1/4"gap, e 9 0.350 0 13.1 118 34.0 306 1/8"thk;NFRC rated(SHGC=0.29);1.5 ft overhang(1.5 ft window ht, 10 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, e 8 0.350 0 13.1 98 31.0 233 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(3 ft window ht, w 15 0.350 0 13.1 197 31.0 466 0.67 ft sep.);6.67 ft head ht all 23 0.350 0 13.1 295 31.0 698 2A-2ov:2 glazing,dr outr,air gas,vnl frm mat,dr low-e innr,1/4"gap, e 8 0.350 0 13.1 105 34.0 272 1/8"thk;NFRC rated(SHGC=0.29);1.5 ft overhang(3 ft window ht,10 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, e 60 0.350 0 13.1 788 32.2 1934 1/8"thk;NFRC rated(SHGC4129);1.3 ft overhang(5 ft window ht, 0.67 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, e 17 0.350 0 13.1 217 32.4 534 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(5.5 ft window ht, w 66 0.350 0 13.1 866 32.4 2138 0.67 ft sep.);6.67 ft head ht at 83 0.350 0 13.1 1083 32.4 2672 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, e 36 0.350 0 13.1 473 34.0 1224 1/8"thk;NFRC rated(SHGC�.29);1.5 ft overhang(6 ft window ht,10 ft sep.);6.67 ft head ht 100-m:2 glazing,clr outr,air gas,mtl no brk frm mat,clr low-e innr,1/4" s 21 0.350 0 13.1 280 8.55 182 gap,1/8"thk;NFRC rated(SHGC=129);13 ft overhang(8 ft window ht, 1 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, s 20 0.350 0 13.1 263 12.2 245 1/8"thk;NFRC rated(SHGC=0.29);1.3 ft overhang(4.3 ft window ht,1 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,ck low-e innr,1/4"gap, s 33 0.350 0 13.1 433 14.4 475 1/8"thk;NFRC rated(SHGCO.29);1.3 ft overhang(5.5 ft window ht, 6.83 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, s 36 0.350 0 13.1 473 12.2 440 1/8"thk;NFRC rated(SHGC�.29);9.5 ft overhang(6 ft window ht,1 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, s 8 0.350 0 13.1 105 12.2 98 1/8"thk;NFRC rated(SHGC=.29);13 ft overhang(8 ft window ht,1 ft sep.);6.67 ft head ht 10C-m:2 glazing,clr outr,air gas,mtl no brk frm mat,clr low-e innr,1/4" w 21 0.350 0 13.1 280 22.2 474 gap,1/8'title;NFRC rated(SHGC�.29);3 ft overhang(8 ft window ht, 1.67 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, w 18 0.350 0 13.1 236 34.0 612 1/8"thk;NFRC rated(SHGC 0.29);1.5 ft overhang(3 ft window ht, 11.67 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,clr low-e innr,1/4"gap, w 16 0.350 0 13.1 210 34.0 544 1/8"thk;NFRC rated(SHGC ).29);1.3 ft overhang(4 ft window ht, 1.17 ft sep.);6.67 ft head ht 2A-2ov:2 glazing,clr outr,air gas,vnl frm mat,cir low-e innr,1/4"gap, w 11 0.350 0 13.1 151 31.9 366 1/8"thk;NFRC rated(SHGC�.29);1.3 ft overhang(4.3 ft window ht, 0.67 ft sep.);6.67 ft head ht Doors 11 D0:Door,wd sc type n 18 0.390 0 14.6 261 11.8 210 Ceilings 16X19-0ad:Attic ceiling,asphalt shingles roof mat,r-20 roof ins,1/2" 2031 0.408 19.0 2.12 4312 1.57 3185 gypsum board int fnsh Floors 20P-13c:Fir floor,frm flr,6"thkns,carpet fir fnsh,r-13 cav ins,amb ow 304 0.068 13.0 2.55 775 0.93 283 20P-13c:Ft:floor,frm flr,6'thkns,carpet flr fnsh,r-13 cav ins,gar ow 399 0.068 13.0 2.55 1017 0.93 372 22A-cpl:Bg floor,light dry soil,on grade depth,carpet flr fnsh 142 0.989 0 37.1 5248 0 0 2016-Apr-08 15:36:53 1�C� ^ wrightsoft Right-Suites Universal 2015 15.0.24 RSU24006 Page 2 /+C �+ ...s1PillarConstnictionJax1CoralStreet\CoralSt.rup Cale=MJ8 House laces: S FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. i ] R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55`F(13°C)shall be insulated to a minimum of R-3., o R403.3.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. I I R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.4.4 Water heater efficiencies(Mandatory). Water heater efficiencies • R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water heating systems to be turned off. • R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal:and 2. Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory).The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. o R403.5.1 Whole-house mechanical ventilation system fan efficacy. Mechanical ventilation system fans shall meet the efficacy requirements of Table R403.5.1. Exception:W here mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.5.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62,Ventilation for Acceptable Indoor Air Quality.shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioned system make air shall be provided to conditioned space from attics,crawlspaces,attached closed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. U R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 4/8/2016 10:56 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compli Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. C) R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. C.1 R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal • efficiency of 82 percent for heaters manufactured on or after April 16.2013 when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters.pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar ▪ energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O 8405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 4/8/2016 10:56 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compli Page 3 of 3