363 12 th st - ENERGY SHEETS (2) 431- Job:- wrightsoft Manual S Compliance Report Date: 7/5/16 • 1st Floor OFFICE COMFY' M.Ellis Energy Design Systems, Inc. 11727 Brady Rd.Jacksonville,FL 32223 Phone 904-268-3670 Fax 904-268-3670 Email:eds.jax@gmail.com Project Information For: Hand Residence 363 12th St,Atlantic Beach, FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 43578 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latent gain: 6516 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 50093 Btuh Indoor RH: 50% Estimated airflow: 1917 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Trane Model: 4TWR5061E 1+TAM7B0C6OH 51 Actual airflow: 1917 cfm Sensible capacity: 38700 Btuh 89% of load Latent capacity: 16400 Btuh 252% of load Total capacity: 55100 Btuh 110% of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 31559 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Trane Model: 4TWR5061E1+TAM7B0C6OH51 Actual airflow: 1917 cfm Capacity balance: 23 °F Output capacity: 55500 Btuh 176% of load Economic balance: 23 °F Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1917 cfm IIECIEDVE Output capacity: 9.2 kW 100% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. AUG 1 9 2016 2016-Aug-09 17 38 06 t +INF wrightsoft Right-Suite®Universal 2017 17 0 04 RSU17457 1157"r"..." / ak ..nual J\Hand Residence,363 12th St,All Bch.rup Calc=MJ8 Front Door faces. S Manual S Compliance Report Job. -+ d- wrightsoft p Date: 715116 2nd Floor By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville. FL 32223 Phone 904-268-3670 Fax.904-268-3670 Email.eds.jax@gmail.com Project Information For: Hand Residence 363 12th St,Atlantic Beach, FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 35889 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latent gain: 6024 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 41913 Btuh Indoor RH: 50% Estimated airflow: 1633 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Trane Model: 4TWR5049E1+TAM7A0C48H41 Actual airflow: 1633 cfm Sensible capacity: 33900 Btuh 94% of load Latent capacity: 12600 Btuh 209% of load Total capacity: 46500 Btuh 111% of load SHR: 73% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 23755 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASH P Manufacturer: Trane Model: 4TWR5049E1+TAM7A0C48H41 Actual airflow: 1633 cfm Output capacity: 47500 Btuh 200% of load Capacity balance: 19 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1633 cfm Output capacity: 7.0 kW 100% of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Aug-09 17 38 06 ti wrightsoft Right-Suite®Universal 2017 17.0 04 RSU17457 Page 2 ACCt ..nual 11-land Residence.363 12th St,All Bch rup Calc=MJ8 Front Door faces. S FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hand Residence Builder Name: Street: 363 12th St Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach.FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types (7351.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 7186.00 ft' b.Frame-Wood,Adjacent R=19.0 165.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 6 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (3975.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=19.0 3975.00 ft' 6. Conditioned floor area above grade(ft') 6160 b.N/A R= ft' Conditioned floor area below grade(ft2) 0 c.NIA R= ft2 11.Ducts R ft' 7. Windows(1511.0 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor.AH: 1st Floor 6 430.04 a. U-Factor: Dbl,U=0.40 1511.00 ft' b.Sup: 2nd Floor,Ret:2nd Floor,AH:2nd Floor 6 370.76 SHGC: SHGC=0.25 b. U-Factor N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 55.1 SEER:15.00 b.Central Unit 46.5 SEER:15.50 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a.Electric Heat Pump 55.5 HSPF:8.50 SHGC: b.Electric Heat Pump 47.5 HSPF:9.00 Area Weighted Average Overhang Depth: 5.753 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems a.Propane Tankless Cap: 1 gallons 8. Floor Types (6160.0 sqft.) Insulation Area EF:0.750 a.Slab-On-Grade Edge Insulation R=0.0 3308.00 ft' b. Conservation features b.Floor Over Other Space R=0.0 2825.00 ft' None c.other(see details) R= 27.00 ft2 15.Credits None Total Proposed Modified Loads: 150.50 PASS Glass/Floor Area: 0.245 Total Baseline Loads: 155.02 I hereby certify that the plans and specifications covered by Review of the plans and :.•''oF'CE STg1�••.,. this calculation are in compliance with the Florida Energy specifications covered by this 1,. .......ti: ; .,:04,•: calculation indicates compliance '• ii Ryan B.Ellis with the Florida Energy Code. ...1.0,q ••,,.,...,.... °,l:0 • •71 PREPARED BY: Before construction is completed e a f• �, - DATE: 7/17/16 this building will be inspected for O o •Y compliance with Section 553.908 *`... Florida Statutes. : f ''r �'r ''s' I hereby certify that this budding, • designed, is in compliance •.,+ ' 4, with the Florida Energy �. / ' COD WE 0 , / OWNER/AGENT: Imo. - _. BUILDING OFFICIAL: DATE: _ i_,____ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: Hand Residence Bedrooms: 6 Address Type: Street Address Building Type: User Conditioned Area: 6160 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 363 12th St Permit Office: Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Block/ 3308 33080 2 Block2 2852 34224 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infi1ID Finished Cooled Heated 1 1st Floor 3308 33080 Yes 4 1 1 Yes Yes Yes 2 2nd Floor 2852 34224 No 5 5 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulation 1st Floor 339.1 ft 0 3308 ft' — 0 0 1 2 Raised Floor 2nd Floor — ____ 27 ft2 19 0 0 1 3 Floor Over Other Space 2nd Floor ____ ____ 2825 ft' 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 3999 ft' 1110 ft' Medium 0.96 No 0.9 No 19 33.7 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 3327 ft2 N N 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING V # Ceiling Type _ Space R-Value_ Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) 1st Floor 0 Blown 580 ft2 0.11 Wood 2 Under Attic(Unvented) 2nd Floor 0 Blown 3395 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Omt - To Wall type_- Space R-value Ft In Et In- Area -R-Value-Fraction--Absor. Grade% 1 S Exterior Frame-Wood 1st Floor 19 48 10 480.0 ft2 0.05 0.170000 0 2 S Exterior Frame-Wood 1st Floor 19 21 10 210.0 ft2 0.05 0.170000 0 3 W Exterior Frame-Wood 1st Floor 19 4 22 88.0 ft2 0.05 0.170000 0 - 4 S Exterior Frame-Wood 1st Floor 19 16 22 352.0 ft2 0.05 0.170000 0 - 5 E Exterior Frame-Wood 1st Floor 19 4 22 88.0 ft2 0.05 0.170000 0 6 E Exterior Frame-Wood 1st Floor 19 67.2 10 672.0 ft2 0.05 0.170000 0 7 N Exterior Frame-Wood 1st Floor 19 16.5 10 165.0 ft2 0.05 0.170000 0 - 8 W Exterior Frame-Wood 1st Floor 19 68.6 10 686.0 ft2 0.05 0.170000 0 9 W Exterior Frame-Wood 1st Floor 19 12 10 120.0 ft2 0.05 0.170000 0 _10 N Exterior Frame-Wood 1st Floor 19 52 10 520.0 ft2 0.05 0.170000 0 _11 E Exterior Frame-Wood 1st Floor 19 13.3 10 133.0 ft2 0.05 0.170000 0 12 N Garage Frame-Wood 1st Floor 19 16.5 10 165.0 ft2 0.05 0.170000 0 _13 S Exterior Frame-Wood 2nd Floor 19 69 12 828.0 ft2 0.05 0.170000 0 _14 E Exterior Frame-Wood 2nd Floor 19 76 12 912.0 ft2 0.05 0.170000 0 15 N Exterior Frame-Wood 2nd Floor 19 85 12 1020.0 ft2 0.05 0.170000 0 16 W Exterior Frame-Wood 2nd Floor 19 76 12 912.0 ft2 0.05 0.170000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood 1st Floor None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered. Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.4 0.25 126.0 ft2 1 ft 0 in 12 ft 0 in Drapes/blinds None 2 S 2 Vinyl Low-E Double Yes 0.4 0.25 72.0 ft2 8 ft 0 in 2 ft 0 in Drapes/blinds None 3 W 3 Vinyl Low-E Double Yes 0.4 0.25 54.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 4 E 6 Vinyl Low-E Double Yes 0.4 0.25 126.0 ft2 1 ft 0 in 13.6 ft 0 i Drapes/blinds None 5 N 7 Vinyl Low-E Double Yes 0.4 0.25 54.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 6 W 8 Vinyl Low-E Double Yes 0.4 0.25 18.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 7 W 8 Vinyl Low-E Double Yes 0.4 0.25 48.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 8 W 9 Vinyl Low-E Double Yes 0.4 0.25 48.0 ft2 52 ft 0 in 2 ft 0 in Drapes/blinds None 9 N 10 Vinyl Low-E Double Yes 0.4 0.25 288.0 ft2 12 ft 0 in 2 ft 0 in Drapes/blinds None 10 E 11 Vinyl Low-E Double Yes 0.4 0.25 18.0 ft2 52 ft 0 in 2 ft 0 in Drapes/blinds None 11 E 6 Vinyl Low-E Double Yes 0.4 0.25 24.0 ft2 4 ft 0 in 2 ft 0 in Drapes/blinds None 12 W 8 Vinyl Low-E Double Yes 0.4 0.25 24.0 ft2 4 ft 0 in 2 ft 0 in Drapes/blinds None 13 W 8 Vinyl Low-E Double Yes 0.4 0.25 18.0 ft2 1 ft 0 in 13.6 ft 0 i Drapes/blinds None 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 14 W 8 Vinyl Low-E Double Yes 0.4 0.25 9.0 ft2 1 ft 0 in 13.6 ft 0 i Drapes/blinds None 15 S 13 Vinyl Low-E Double Yes 0.4 0.25 144.0 ft 1 ft 0 in 2 ft 0 in Drapes/blinds None 16 S 13 Vinyl Low-E Double Yes 0.4 0.25 8.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 17 S 4 Vinyl Low-E Double Yes 0.4 0.25 36.0 ft' 1 ft 0 in 2 ft 0 in Drapes/blinds None 18 E 14 Vinyl Low-E Double Yes 0.4 0.25 72.0 ft' 1 ft 0 in 2 ft 0 in Drapes/blinds None 19 E 14 Vinyl Low-E Double Yes 0.4 0.25 27.0 ft' 1 ft 0 in 2 ft 0 in Drapes/blinds None 20 N 15 Vinyl Low-E Double Yes 0.4 0.25 36.0 ft' 1 ft 0 in 2 ft 0 in Drapes/blinds None 21 W 16 Vinyl Low-E Double Yes 0.4 0.25 18.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 22 N 15 Vinyl Low-E Double Yes 0.4 0.25 108.0 ft' 1 ft 0 in 2 ft 0 in Drapes/blinds None 23 E 14 Vinyl Low-E Double Yes 0.4 0.25 18.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 24 E 14 Vinyl Low-E Double Yes 0.4 0.25 9.0 ft' 1 ft 0 in 2 ft 0 in Drapes/blinds None 25 W 16 Vinyl Low-E Double Yes 0.4 0.25 18.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 26 W 16 Vinyl Low-E Double Yes 0.4 0.25 90.0 ft' 1 ft 0 in 2 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 1224 ft2 1224 ft2 136.5 ft 10ft 0 INFILTRATION 4 Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000347 5608.7 307.91 579.07 .3291 5 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 55.5 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:9 47.5 kBtu/hr 2 sys#2 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15 55.1 kBtu/hr 1653 cfm 0.75 1 sys#1 2 Central Unit None SEER: 15.5 46.5 kBtu/hr 1395 cfm 0.75 2 sys#2 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.75 1 gal 90 gal 120 deg None • 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 i FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft? DUCTS , ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 430.04 f 1st Floor 165.4 ft2 Default Leakage 1st Floor (Default)c(Default)c 1 1 2 2nd Floor 6 370.76 f 2nd Floor 142.6 ft2 Default Leakage 2nd Floor (Default)c(Default)c 2 2 TEMPERATURES Programable Thermostat: None Ceiling Fans: Cooling Jan Feb ( Mar ZrMa X]Jun X Jul X Au X Se [ ]Oct [ Nov Dec Heatinil Jan "XiFeblx Mar rl Mal JunJull AuSepOctNovl DecVentin Jan Feb [X' Mar `X Apr [ May [ ]Jun Jul ( Aug Sep [X]Oct [[X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 363 12th St, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 7166.00 ft2 b.Frame-Wood,Adjacent R=19.0 165.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 6 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 3975.00 ft2 6. Conditioned floor area(ft2) 6160 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 11.Ducts R ft2 a. U-Factor: Dbl,U=0.40 1511.00 ft2 a.Sup: 1st Floor,Ret: 1st Floor,AH: 1st Floor 6 430.04 SHGC: SHGC=0.25 b.Sup: 2nd Floor,Ret:2nd Floor,AH:2nd Floor 6 370.76 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 55.1 SEER:15.00 SHGC: b.Central Unit 46.5 SEER:15.50 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 55.5 HSPF:8.50 Area Weighted Average Overhang Depth: 5.753 ft. b. Electric Heat Pump 47.5 HSPF:9.00 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 3308.00 ft2 a.Propane EF:0.75 b.Floor Over Other Space R=0.0 2825.00 ft2 c.other(see details) R= 27.00 ft2 b. Conservation features None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building •.�•'' 1ESrq'•• Construction through the above energysavingfeatures which will be installed (or exceeded) .0 ....of "" TFp` in this home before final inspect• . Otherwise, a new EPL Display Card will be completed .4.7./;,'"1�;'s, ,,.�•..n based on installed Code ompl.. t features. '41-'I' � ' W /Ill __+Y..-�.� . 7'i Builder Signature: / Date: ..-7/72:1 16 '•Mo.' a a ; - •- . -- ! - �• QTY .' '� Address of New Horn {• rew\ _ City/ Zip: 32- '•.;mac* `_.: v5 oo fi••; '.e..«..•r. I *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 363 12th St Permit Number: Atlantic Beach,FL MANDATORY REQUIREMENTS See individual code sections for full details. X 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law[Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. X R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. X R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official.an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures: 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3.Interior doors,if installed at the time of the test,shall be open: 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and 6.Supply and return registers,if installed at the time of the test,shall be fully open. X R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. X R402.4.3 Fenestration air IeakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. X R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. X R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. X R403.1.3 Heat pump supplementary heat(Mandatory)Heat pumps having supplementary electric-resistance heat shall have controls that. except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. X R403.2.2 Sealing(Mandatory/NI ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm(85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compli Page 1 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. X R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13°C)shall be insulated to a minimum of R-3.. R403.3.1 Protection of piping insulation. 0 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. X R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%I inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. X R403.4.4 Water heater efficiencies(Mandatory). X R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water heating systems to be turned off. X R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions.for the type of equipment installed.Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar • Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal:and 2. Be installed at an orientation within 45 degrees of true south. p R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code.Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. X R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment X R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies.based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compli Page 2 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data.the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space Exceptions 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. X R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. X R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14 O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16.2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar ' energy source computed over an operating season. X RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights X R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. X R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space.R-10 is allowed. 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compli Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hand Residence Builder Name: Street: 363 12th St Permit Office: Atlantic Beach City.State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. X Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. X Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. X Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and X Rim joists Rim joists are insulated and include an air barrier. X Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. X The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. X Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or X unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity X spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. X Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be X air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to X available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air X barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or X air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be X sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have X gasketed doors 7/17/2016 2:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 ir Wrl htsoft Job: Project Summary Date: 715)16 9 1st Floor By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville,FL 32223 Phone 904-268-3670 Fax 904-268-3670 Email:eds.jax@gmad corn Project Information For: Hand Residence 363 12th St,Atlantic Beach. FL Notes: Desi• n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 To Moisture difference 50 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 31559 Btuh Structure 43578 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31559 Btuh Use manufacturer's data Y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 43578 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 6516 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 3308 3308 Equipment latent load 6516 Btuh Volume (ft') 35732 35732 Air changes/hour 0.28 0.14 Equipment total load 50093 Btuh Equiv.AVF (cfm) 169 85 Req. total capacity at 0.72 SHR 5.0 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR5061E1 Cond 4TWR5061E1 AH RI ref 5315804 Coil TAM7B0C60H51 AH RI ref 5315804 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 38570 Btuh Heating output 55500 Btuh @ 47°F Latent cooling 16530 Btuh Temperature rise 26 °F Total cooling 55100 Btuh Actual air flow 1917 cfm Actual air flow 1917 cfm Air flow factor 0.061 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Jul-17 14 39 54 Wrlghtsoft Right-Suite®Universal 2017 17.0 01 RSU17457 Page 1 ACCA _nual J11-land Residence,363 12th St,Atl Bch rup Calc=MJ8 Front Door faces S 4 wrightsoft Project Summary Job:Date: 7/5/16 2nd Floor By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville, FL 32223 Phone:904-268-3670 Fax.904-268-3670 Email eds jax@grnail.com Pro'ect Information For: Hand Residence 363 12th St,Atlantic Beach. FL Notes: Desi• n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23755 Btuh Structure 35889 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23755 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 35889 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 6024 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 2852 2852 Equipment latent load 6024 Btuh Volume (ft3) 33782 33782 Air changes/hour 0.31 0.16 Equipment total load 41913 Btuh Equiv.AVF (cfm) 175 88 Req. total capacity at 0.74 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade TRANE Trade TRANE Model 4TWR5049E1 Cond 4TWR5049E1 AHRI ref 4385456 Coil TAM7A0C48H41 AHRI ref 4385456 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 32550 Btuh Heating output 47500 Btuh @ 47°F Latent cooling 13950 Btuh Temperature rise 26 °F Total cooling 46500 Btuh Actual air flow 1633 cfm Actual air flow 1633 cfm Air flow factor 0.069 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ..p���.'"�. 2016-Jul-17 14 39 54 -fie- wrightsoft Right-Suite®Universal 2017 17 0 01 RSU17457 Page 2 ACCP. .nual J\Hand Residence.363 12th St,Atl Bch.rup Calc=MJ8 Front Door faces S N 1st Floor 130 ctm �~ 130 ctm y °-169c 752 cfm '10" ,7. I RI 571 cfm 117- 10• •1s• I '`'72 cfm 0 92 cfmI 04 cfm ° 101 cfm s• 101 c*n On n Tg - 4 Sup R xr – — —i —1 y:•-- — — y + ry`879 cfm n- 10• 9' 9• f*1.208 cfm ®211 cfm f-�125 cfm 1i1,125 cfm Job #: Scale: 1 : 135 Exclusively for the use of: Performed for: Page 1 Hand Residence Environmental Air Conditioning Services,Inc. Right-Suite&Universal 2017 363 12th St2016-Jul-17 14:40:38 17.0.01 RSU17457 Atlantic Beach.FL ...idence,363 12th St,All Bch.rup N ,1 \ 2nd Floor 11' 107 cfm 034 cfm 146 c m ® f� 55 dm Wi-268 cfm I 5 '6" I 2129 cfm ®33cfm I 1'177 elm 9' I 5" 9" I 119 efm 70 cfm 2127 cfm 2182:fm 12" 7' ,.•, 54c w....28efm °21 dm (425 elm 14229n 5" 5' W1 W1115 115cfm '309cfm I Wi339cfm 4" 8" I I 8" 6' 5' `70' 4" 4' •9' 113' 173- 1 cfm I °98:11 ��' „Ic 12" — i-i 847 cfm 1' _-- .130 cfm Job #: scale: 1 : 135 Exclusively for the use of: Performed for: Page 2 Hand Residence Environmental Air Conditioning Services,Inc. Right-Suite€Universal 2017 363 12th St2016-Jul-17 14:40:38 ...idence, RSU17457 Atlantic Beach,FL nce,363 12th St,Atl Bch.rup 4 wrightsoft Duct System Summary Date: 1st Floor By: Exclusively for the use of: Environmental Air Conditioning Services. Inc Project Information For: Hand Residence 363 12th St,Atlantic Beach, FL Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/ return available pressure 0.065/ 0.035 in H2O 0.065/ 0.035 in H2O Lowest friction rate 0.018 in/100ft 0.018 in/100ft Actual air flow 2000 cfm 2000 cfm Total effective length (TEL) 553 ft Supply Branch Detail Table fDesign Htg I Cig Design Diam H x W I Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Beach Bath h 1914 70 69 0.023 7.0 Ox 0 ShMt 28.0 255.0 st3 Den h 5712 208 206 0.022 11.0 Ox 0 ShMt 77.0 220.0 st3 Dining h 2524 92 89 0.023 8.0 Ox 0 ShMt 34.0 255.0 st3 Drop h 3325 121 121 0.043 8.01 Ox 0 ShMt 23.0 I 130.0 Exercise-A c 3745 126 130 0.018 10.01 Ox 0 ShMt 106.0 255.0 st3 1 Exercise-13 c 3745 126 130 0.020 9.01 Ox 0 ShMt 100.0 230.0 st3 Foyer c 3603 124 125 0.022 9.01 Ox 0 ShMt 47.0 255.0 st3 Guest&Play h 4652 169 169 I 0.021 10.01 Ox 0 ShMt 87.0 220.0 st3 Guest Bath h 1978 72 72 I 0.020 8.0 Ox 0 I ShMt I 78.0 255.0 st3 Homework h 3434 125 123 I 0.023 9.0 Ox 0 ShMt I 30.0 255.0 st3 Kitchen c 2903 100 101 I 0.024 8.0 Ox 0 ShMt 16.0 255.0 st3 Kitchen-A c 2903 100 101 I 0.023 8.0 Ox 0 ShMt 24.0 255.0 I st3 Laundry 1 c 4260 1471 148 0.032! 9.01 Ox 0 I ShMt 32.0 175.0 st3 Living I h 2856 1041 102 0.022! 8.01 Ox 0 I ShMt 49.0 245.0 st3 living-B h 2856 1041 102 0.022 9.01 Ox 0 ShMt 61.0 240.0 st3 Pantry 1 C 6077 2111 211 0.035 10.01 Ox 0 ShMt 10.0 175.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W I Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 1879 1879 0.018 551 25.0 0 x 0 ShtMetl Bold/italic values have been manually overridden _�J. 2016-Jul-17 14:40:19 .` wrightsoft Right-Suite®Universal 2017 17 0 01 RSU17457 Page 1 ACC nual D\Hand Residence.363 12th St.Atl Bch rup Calc=MJ8 faces S Return Branch Detail Table Grill Htg Clg I TEL I Design I Veloc I Diam H x W Stud/Joist Duct I Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 750 752 132.0 0.026 477 17.0 Ox 0 ShMt rt3 rb12 Ox 0 571 570 192.0 0.018 409 16.01 Ox 0 ShMt rt3 1 rb13 Ox 0 679 678 184.0 0.019 I 431 I 17.01 Ox 0 ShMt 1 rt3 Return Trunk Detail Table Trunk Htg I Clg Design Veloc Diam I H x W I Duct I I Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt3 Peak AVF 2000 2000 0.018 542 26.0 0 x 0 ShtMetl 2016-Jul-17 14:40:19 41- W rightsoft` Right-Suite®Universal 2017 17 0 01 RSU17457 Page 2 ACCP, nual D\Hand Residence.363 12th St.All Bch rup Calc=MJ8 faces S wrightsoft Duct System Summary Date: 4 2nd Floor By: Exclusively for the use of: Environmental Air Conditioning Services. Inc Project Information For: Hand Residence 363 12th St,Atlantic Beach, FL Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/ return available pressure 0.067/ 0.033 in H2O 0.067/ 0.033 in H2O Lowest friction rate 0.016 in/100ft 0.016 in/100ft Actual air flow 1600 cfm 1600 cfm Total effective length (TEL) 641 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual l Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 1 h 1976 54 53 0.030 6.0 Ox 0 ShMt 63.0 160.0 st2 Bath 2 h 1971 54 52 0.028 6.0 Ox 0 ShMt 40.0 195.0 st2 Bath 3 c 1166 29 29 0.033 5.0 Ox 0 ShMt 28.0 175.0 st1 Bath 41 c 1325 331 33 0.023 5.0 Ox 0 1 ShMt 35.0 255.0 st1 Child 1 h 5340 146 146 0.032 9.0 Ox 0 1 ShMt 56.0 150.0 st2 Child 2 c 4675 116 117 0.038 8.0 Ox 0 ShMt 27.0 I 150.0 st2 Child 3 c 4771 118 119 0.034 8.0 Ox 0 ShMt 19.0 1 175.0 st2 Child 4 c 2784 1 66 70 0.018 7.0 I Ox 0 ShMt 40.0 I 335.0 st1 Computer h 2810 1 77 75 0.032 7.0 Ox 0 I ShMt 35.0 I 175.0 st2 Her WIC c 2181 I 54 55 0.016 7.0 Ox 0 I ShMt 74.0 355.0 st1 His WIC 1 C 1089 1 25 27 0.0181 4.0 Ox 0 1 ShMt 49.0 325.0 st1 Laundry 2 h 5350 1 147 145 0.0361 9.0 Ox 0 ShMt 9.0 175.0 st2 Master Bath I h 3883 107 106 0.017 9.01 Ox 0 I ShMt 81.0 320.0 st1 Master Bed I c 3293 78 82 0.018 8.01 Ox 0 I ShMt 60.0 310.0 st1 Office I h 4728 130 126 0.025 9.01 Ox 0 ShMt 11.0 255.0 st1 Sitting c 3937 I 97 98 0.019 9.01 Ox 0 ShMt I 47.0 310.0 st1 Toilet h 1231 34 33 0.017 5.0 Ox 0 ShMt I 84.0 320.0 st1 Upper Hall h 4729 130 128 0.018 10.0 Ox 0 ShMt I 30.0 335.0 st1 WIC 1 h 1238 34 33 0.029 5.0 Ox 0 ShMt 71.0 I 160.0 st2 WIC 2 h 1017 28 27 0.0341 5.0 Ox 0 ShMt 32.0 165.0 st2 WIC 3 I C 848 I 211 21 1 0.0341 4.01 Ox 0 ShMt 19.0 175.0 st1 1 WIC 4 I c 989 1 241 25 1 0.0241 4.01 Ox 0 ShMt 26.0 I 255.0 1 st1 1 Bold/italic values have been manually overridden 2016-Jul-17 14 40 19 wrightsoft Right-Suite®Universal 2017 17 0.01 RSU17457 Page 3 ACCP nual D\Hand Residence.363 12th St.All Bch nip Calc=MJB faces S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam I H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 825 833 0.016 423 19.0 0 x 0 ShtMetl st2 ' Peak AVF 775 767 0.028 491 17.0 0 x 0 ShtMetl Return Branch Detail Table Grill Htg Clg 1 TEL Design Veloc Diam H x W Stud/Joist Duct 1 Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb6 Ox 0 289 284 140.0 0.024 368 12.0 Ox 0 ShMt rt2 rb7 Ox 0 339 338 135.0 0.0241 368 13.0 Ox 0 ShMt rt2 rb8 Ox 0 229 228 92.0 I 0.0361 420 1 10.0 Ox 0 ShMt rt1 rb9 I Ox 0 113 115 129.0 0.026 259 9.0 Ox 0 ShMt rt1 rb10 I Ox 0 305 309 212.0 0.016 336 13.01 Ox 0 ShMt rt1 rb11 Ox 0 326 326 98.0 1 0.034 415 12.01 Ox 0 1 ShMt rt1 Return Trunk Detail Table Trunk Htg Clg I Design Veloc Diam H x W I Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 972 978 0.016 448 20.0 0 x 0 ShtMetl rt2 Peak AVF 628 622 0.024 450 1 16.0 0 x 0 ShtMetl 1 2016-Jul-17 14.40 19 WrightSOft Right-Suite®Universal 2017 17.0.01 RSU17457 Page 4 /t'CCA _nual D\Hand Residence,363 12th St,AB Bch.rup Calc=MJ8 faces S