987 ENERGY SHEETS FILE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0316112 Builder Name: Solar Home Developers.LLC Street: Camelia St. Permit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach, FL, Permit Number: Owner: Miller Residence Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(2413.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood, Exterior R=13.0 2098.40 ft2 b.Frame-Wood,Adjacent R=13.0 315.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1034.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1034.00 ft2 6. Conditioned floor area above grade(ft2) 1631 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11.Ducts R ft2 7. Windows(250.4 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Garage 6 225 a. U-Factor: Dbl•U=0.29 250.44 ft2 SHGC: SHGC=0.23 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 34.6 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.651 ft. Area Weighted Average SHGC: 0.230 14. Hot water systems 8. Floor Types (1034.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 657.00 ft2 b. Conservation features b. Floor over Garage R=19.0 377.00 ft2 None c. N/A R= ft2 15.Credits CF Total Proposed Modified Loads: 55.32 PASS Glass/Floor Area: 0.154 Total Baseline Loads: 55.77 I hereby certify that the plans and specifications covered by Review of the plans and .:.•'�4�KESTgr�••.,, this calculation are in compliance with the Florida Energy specifications covered by this •/41-...,;. „v. •-•";,?:* O Code. calculation indicates compliance • h::,/, , '..."',..6.• j' with the Florida Energy Code. /lw,i' - ;'�••w„'•�O 1. PREPARED BY: Before construction is completed 1f • ..:;ti .. r `s 03-23-16 this buildingwill be inspected for DATE: __ ._ . p : � : ' -�--_ .a compliance with Section 553.908 a , Florida Statutes. •• I hereby certify that this building, as designed, is in compliance ••.,CYC ...,.•••••• �c� ,o with the Florida Energy Code / m OD 1� .• OWNER/AGE�I :% /`/ BUILDING OFFICIAL: / ' '1)" DATE: .S at/ 1 G DATE: V_ 9h/-i6----_ f - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/23/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: R0316112 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1631 Lot# Owner: Miller Residence Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Solar Home Developers,LLC Rotate Angle: 0 Street: Camelia St. Permit Office: City of Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261100 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Entire House 1631 15229.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 HBath 54 1036.8 No 0 1 Yes Yes Yes 2 Entry 78 699 No 0 1 Yes Yes Yes 3 Stairs 39 349 No 0 1 Yes Yes Yes 4 Great Rm 248 2230 No 0 1 Yes Yes Yes 5 Kitchen Dining 238 2142 Yes 0 1 Yes Yes Yes 6 Master Bedroom 194 1746 No 2 1 1 Yes Yes Yes 7 Mwic 28 255 No 0 1 Yes Yes Yes 8 Laundry 48 432 No 0 1 No Yes Yes 9 Loft 170 1530 No 0 1 Yes Yes Yes 10 MBath 88 792 No 0 1 Yes Yes Yes 11 Mwic2 30 270 No 0 1 Yes Yes Yes 12 Mtlt 28 252 No 0 1 Yes Yes Yes 13 Bedroom2 141 1269 No 1 1 1 Yes Yes Yes 14 Bath2 65 585 No 0 1 Yes Yes Yes 15 Bedroom3 182 1638 No 1 1 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio HBath 14.7 ft 0 54 ft2 ____ 0 0 1 2 Slab-On-Grade Edge Insulatio Entry 6.7 ft 0 78 ft2 ____ 0 0 1 3 Slab-On-Grade Edge Insulatio Stairs 6.3 ft 0 39 ft2 ____ 0 0 1 3/23/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet , 4 Slab-On-Grade Edge lnsulatio Great Rm 32 ft 0 248 ft2 ____ 0 0 1 5 Slab-On-Grade Edge lnsulatio Kitchen Dining 36 ft 0 238 ft2 ____ 0 0 1 6 Floor over Garage Loft ____ ___ 83 ft2 19 0 0 1 7 Floor over Garage Bedroom2 ___ 48 ft2 19 0 0 1 8 Floor over Garage Bath2 _- 65 ft2 19 0 0 1 9 Floor over Garage Bedroom3 ___ ___ 181 ft2 19 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1156 ft2 258 ft2 Medium 0.65 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1034 ft2 N N CEILING V # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) HBath 30 61 ft2 0.1 Wood 2 Under Attic(Vented) Master Bedroom 30 194 ft2 0.1 Wood 3 Under Attic(Vented) Mwic 30 28 ft2 0.1 Wood 4 Under Attic(Vented) Laundry 30 48 ft2 0.1 Wood 5 Under Attic(Vented) Loft 30 170 ft2 0.1 Wood 6 Under Attic(Vented) MBath 30 88 ft2 0.1 Wood 7 Under Attic(Vented) Mwic2 30 30 ft2 0.1 Wood 8 Under Attic(Vented) Mtlt 30 28 ft2 0.1 Wood 9 Under Attic(Vented) Bedroom2 30 141 ft2 0.1 Wood 10 Under Attic(Vented) Bath2 30 65 ft2 0.1 Wood 11 Under Attic(Vented) Bedroom3 30 181 ft2 0.1 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Fraction Absor. Grade% _ 1 N Exterior Frame-Wood HBath 13 9 1 19 3 174.9 ft2 0.6 0.25 0.3 0 _ 2 W Exterior Frame-Wood HBath 13 6 5 19 3 123.5 ft2 0.6 0.25 0.3 0 _ 3 N Exterior Frame-Wood Entry 13 2 4 9 0 21.0 ft2 0.6 0.25 0.3 0 4 W Exterior Frame-Wood Entry 13 4 4 9 0 39.0 ft2 0.6 0.25 0.3 0 _ 5 N Exterior Frame-Wood Stairs 13 6 4 9 0 57.0 ft2 0.6 0.25 0.3 0 _ 6 N Exterior Frame-Wood Great Rm 13 16 8 9 0 150.0 ft2 0.6 0.25 0.3 0 7 E Exterior Frame-Wood Great Rm 13 15 4 9 0 138.0 ft2 0.6 0.25 0.3 0 3/23/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below V# Ornt To Wall Type -Space R-Value Ft In __ t-In Area R-Value Fraction Absor. Grade% 8 N Exterior Frame-Wood Kitchen Dinin 13 4 4 9 0 39.0 ft2 0.6 0.25 0.3 0 9 E Exterior Frame-Wood Kitchen Dinin 13 14 8 9 0 132.0 ft2 0.6 0.25 0.3 0 10 S Exterior Frame-Wood Kitchen Dinin 13 17 0 9 0 153.0 ft2 0.6 0.25 0.3 0 11 N Exterior Frame-Wood Master Bedro 13 12 8 9 0 114.0 ft2 0.6 0.25 0.3 0 12 E Exterior Frame-Wood Master Bedro 13 15 4 9 0 138.0 ft2 0.6 0.25 0.3 0 13 N Exterior Frame-Wood Mwic 13 5 0 9 0 45.0 ft2 0.6 0.25 0.3 0 14 N Exterior Frame-Wood Loft 13 2 4 9 0 21.0 ft2 0.6 0.25 0.3 0 15 W Exterior Frame-Wood Loft 13 9 4 9 0 84.0 ft2 0.6 0.25 0.3 0 16 E Exterior Frame-Wood MBath 13 2 4 9 0 21.0 ft2 0.6 0.25 0.3 0 17 S Exterior Frame-Wood MBath 13 6 0 9 0 54.0 ft2 0.6 0.25 0.3 0 18 N Exterior Frame-Wood Mwic2 13 4 4 9 0 39.0 ft2 0.6 0.25 0.3 0 19 E Exterior Frame-Wood Mwic2 13 6 4 9 0 57.0 ft2 0.6 0.25 0.3 0 20 E Exterior Frame-Wood Mtlt 13 6 0 9 0 54.0 ft2 0.6 0.25 0.3 0 Il 21 S Exterior Frame-Wood Mtlt 13 4 8 9 0 42.0 ft2 0.6 0.25 0.3 0 22 S Exterior Frame-Wood Bedroom2 13 10 0 9 0 90.0 ft2 0.6 0.25 0.3 0 23 S Exterior Frame-Wood Bath2 13 5 8 9 0 51.0 ft2 0.6 0.25 0.3 0 24 N Exterior Frame-Wood Bedroom3 13 2 0 9 0 18.0 ft2 0.6 0.25 0.3 0 25 S Exterior Frame-Wood Bedroom3 13 12 4 9 0 111.0 ft2 0.6 0.25 0.3 0 26 W Exterior Frame-Wood Bedroom3 13 14 8 9 0 132.0 ft2 0.6 0.25 0.3 0 27 S Garage Frame-Wood Entry 13 15 8 9 141.0 ft2 0.23 0.01 0 28 SW Garage Frame-Wood Great Rm 13 5 0 9 45.0 ft2 0.23 0.01 0 29 W Garage Frame-Wood Kitchen Dinin 13 14 4 9 129.0 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Entry None .35 3 6 8 20 ft2 2 S Insulated Entry None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered.Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 TIM Low-E Double Yes 0.29 0.23 6.0 ft2 1 ft 0 in 8 ft 6 in Drapes/blinds Exterior 5 2 W 2 TIM Low-E Double Yes 0.29 0.23 15.0 ft2 6 ft 6 in 1 ft 6 in Drapes/blinds Exterior 5 3 N 6 TIM Low-E Double Yes 0.29 0.23 12.0 ft2 1 ft 0 in 15 ft 0 in Drapes/blinds Exterior 5 4 N 6 TIM Low-E Double Yes 0.29 0.23 12.0 ft2 1 ft 0 in 20 ft 0 in Drapes/blinds Exterior 5 5 E 7 TIM Low-E Double Yes 0.29 0.23 39.4 ft2 8 ft 10 in 1 ft 5 in Drapes/blinds Exterior 5 6 E 9 TIM Low-E Double Yes 0.29 0.23 40.0 ft2 1 ft 0 in 16 ft 0 in Drapes/blinds Exterior 5 7 S 10 TIM Low-E Double Yes 0.29 0.23 9.0 ft2 1 ft 4 in 15 ft 0 in Drapes/blinds Exterior 5 8 N 11 TIM Low-E Double Yes 0.29 0.23 30.0 ft2 1 ft 4 in 1 ft 6 in Drapes/blinds Exterior 5 9 W 15 TIM Low-E Double Yes 0.29 0.23 24.0 ft2 1 ft 0 in 4 ft 5 in Drapes/blinds Exterior 5 10 S 17 TIM Low-E Double Yes 0.29 0.23 8.0 ft2 1 ft 4 in 3 ft 9 in Drapes/blinds Exterior 5 11 E 20 TIM Low-E Double Yes 0.29 0.23 6.0 ft2 1 ft 0 in 4 ft 6 in Drapes/blinds Exterior 5 3/23/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 12 S 22 TIM Low-E Double Yes 0.29 0.23 15.0 ft' 1 ft 4 in 7 ft 6 in Drapes/blinds Exterior 5 13 S 23 TIM Low-E Double Yes 0.29 0.23 4.0 ft' 1 ft 4 in 7 ft 6 in Drapes/blinds Exterior 5 14 W 26 TIM Low-E Double Yes 0.29 0.23 30.0 ft2 1 ft 0 in 5 ft 9 in Drapes/blinds Exterior 5 a GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 474.99 ft' 384 ft' 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000297 1268.8 69.66 131 .2812 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.6 kBtu/hr 1153 cfm 0.73 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage k Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ---Supply— ---Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 225 ft' Attic 150 ft2 Default Leakage Garage (Default) (Default) 1 1 3/23/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 . TEMPERATURES Programable Thermostat: N linJan Feb ( ] Ceilingf ] Fans: Heating X Jan X Feb X1 Mar [ ]Apr [ ]May X]Juun Xjuu�Jul X�Aug x Sep �X Oct �X t Nov Dec Venting Jan Feb X Mar (X]Apr [ ]May [ ]Jun Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/23/2016 2:11 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. Camelia St., Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=13.0 2098.40 ft2 b.Frame-Wood,Adjacent R=13.0 315.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 1034.00 ft2 6. Conditioned floor area(ft2) 1631 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 2 a. U-Factor: Dbl,U=0.29 250.44 ft2 11.Ducts R ft a.Sup:Attic. Ret:Attic,AH:Garage 6 225 SHGC: SHGC=0.23 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.6 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.0 HSPF:8.50 Area Weighted Average Overhang Depth: 2.651 ft. Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 657.00 ft2 a. Electric EF:0.97 b.Floor over Garage R=19.0 377.00 ft2 c. N/A R= ft2 b. Conservation features None 15.Credits CF I certify that this home has complied with the Florida Energy Efficiency Code for Building "AHEST••• Construction through the above energy saving features which will be installed (or exceeded) . 01.....ti;........`9To in this home before final inspection. Otherwise, a new EPL Display Card will be completed 447.;;...''.;s. 4 based on installed Code compliant features. o Builder Signature: _ `//-----? Date: 30 p� 1-///G ::c.,', 4; c :2. Address of New Home: City/FL Zip: r�. ..'y�i clG7 Cane%- /a���� P�t�li C'"........_ Z 30x,33 ° *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/23/2016 2:12 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 System SummaryJab: R0316112 +!+ Duct �wrightsoft Date: 03-23-16 Entire House By: JND Solar Home Developers, LLC 2425 Bentshire Dr.,Jacksonville,FL 32246 Phone:904-472-1459 Project Information For: Miller Residence Camelia St.,Atlantic Beach, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.15 in H2O 0.15 in H2O Available static pressure 0.35 in H2O 0.35 in H2O Supply / return available pressure 0.233/0.117 in H2O 0.233/ 0.117 in H2O Lowest friction rate 0.150 in/100ft 0.150 in/100ft Actual air flow 0 cfm 1153 cfm Total effective length (TEL) 335 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath2 c 719 0 33 0.150 5.0 Ox 0 VIFx 57.7 165.0 st5 Bedroom2 c 1538 0 70 0.150 6.0 Ox 0 VIFx 57.7 165.0 st5 Bedroom3 c 3490 0 159 0.150 8.0 Ox 0 VIFx 57.7 165.0 st5 Great Rm c 1802 0 82 0.150 6.0 Ox 0 VIFx 57.7 165.0 st3 Great Rm-A c 1802 0 82 0.150 6.0 Ox 0 VIFx 57.7 165.0 st3 HBath c 2618 0 119 0.150 7.0 Ox 0 VIFx 57.7 165.0 st3 Kitchen Dining c 2781 0 127 0.150 7.0 Ox 0 VIFx 57.7 165.0 st1 Kitchen Dining-A c 2781 0 127 0.150 7.0 Ox 0 VIFx 57.7 165.0 st1 Laundry c 769 0 35 0.150 5.0 Ox 0 VIFx 57.7 165.0 st4 Loft c 1888 0 86 0.150 6.0 Ox 0 VIFx 57.7 165.0 st4 MBath c 852 0 39 0.150 5.0 Oxo VIFx 57.7 165.0 st6 Master Bedroom c 2896 0 132 0.150 7.0 Ox 0 VIFx 57.7 165.0 st4 Mtlt c 651 0 30 0.150 4.0 Oxo VIFx 57.7 165.0 st6 Mwic c 237 0 11 0.150 4.0 Ox 0 VIFx 57.7 165.0 st4 Mwic2 c 435 0 20 0.150 4.0 Ox 0 VIFx 57.7 165.0 st6 Bold/italic values have been manually overridden 1. W CI ht$Oft 2016-Mar-23 14.48:29 9 Right-Suiten Universal 2015 15.0.21 RSU07440 Page 1 ACCP\ ...ork File\R0316112-967 Camelia St\R0316112 rup Calc=MJ8 House Front faces: W il I Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 0 264 0.150 598 9.0 0 x 0 ViniFlx st2 st6 Peak AVF 0 88 0.150 451 6.0 0 x 0 ViniFlx st5 st5 Peak AVF 0 351 0.150 643 10.0 0 x 0 ViniFlx st2 st2 Peak AVF 0 615 0.150 575 14.0 0 x 0 ViniFlx st3 Peak AVF 0 284 0.150 521 10.0 0 x 0 ViniFlx st1 Peak AVF 0 254 0.150 575 9.0 0 x 0 ViniFlx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 0 384 112.4 0.150 488 12.0 Ox 0 VIFx rt1 rb2 Ox 0 0 231 112.4 0.150 524 9.0 Ox 0 VIFx rt1 rb1 Ox 0 0 538 112.4 0.150 685 12.0 Ox 0 VIFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 0 615 0.150 575 14.0 0 x 0 ViniFlx wrightsoft 2016-Mar-2314:48:29 9 Right-Suffer Universal 2015 15.0.21 RSU07440 Page 2 ACCP. ..ork File\R0316112-967 Camelia St\R0316112.rup Calc=MJ8 House Front faces: W d r.....44, First Floor HVAC Layout I I HAP PORCH I 1 125 cfm 10 x 10 125 cfm r.1 20 x 14 7" 1153 cfm . 1 • 9" 1 103 • 7" , 7" _ 07' aXil AI • i L • • "4.1 .., Sup Riser 14 • r 3dm 'CrIff l‘: I'OWN R I. •• .!f.! •. Tr. FRONT li()RCH •. . ... I . Job it. Performed RbyJ031611ND 2for: Scale:1:56 Solar Home Developers, LLC Papal Miler Residence 2425 Bentshire Dr F461.4-Sulleft Uriversei 2015 907 Carnella St Jacksomalle,FL 32246 15.0.21 RSI.107440 Atla-toe Beach FL 3237 20164.144-22 17:55:44 Phone:904-472-1459 12-967 Camels St1R0316112 nip Second Floor HVAC Layout 8x4 8x4 29cfm 19cfm 4 „ 03 4 " -_- 10x 38 cf 5 " ! 12x12 i 6" 12x6 14x14 L ' 130 cfm 12" - 7" .. 8x4 IA 10x6 11 cfm12x12 69 cfm lI g .. 6• gri 10x6 10x6 32cfL[' ' 35cfm i d5" r — 10 x 6 r►a 85 cfm Sup 'me J 01.4 14 x 8 6 " 14" 157 dm • 12 x 12 8" _ 12rr I_J iti it! H-tt:'llh4 .. ;-_,tit 9-- Job ft Job# R0316112 Solar Home Developers, LLC Scale 1:56 Performed by JND for: Pepe 2 r.m,r ResIden, 2425 Bentshire Righl-SuileeDRS 07440 015 967 Car-L'S' Jacksonville,FL 32246 15.0.21 RS11p7410 I,sem,Brach,Fl 32233 Phone:904-472-1459 2016Mr•2317:SS:53 ...12-9e7 Camelia SSR0315112 rup Manual S Compliance Report Job: R0316112 4- wrightsoft pance p Date: 03-23-16 Entire House By: JND Solar Home Developers, LLC 2425 Bentshire Dr,Jacksonville.FL 32246 Phone:904-472-1459 Project Information For: Miller Residence 967 Camelia St,Atlantic Beach, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.7°F Sensible gain: 25158 Btuh Entering coil DB: 77.9°F Outdoor design WB: 77.1°F Latent gain: 4850 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 30008 Btuh Indoor RH: 50% Estimated airflow: 1153 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox or Eqv. Model: 14HPX-036-230-19+CBX25UHV-036-230-* Actual airflow: 1153 cfm Sensible capacity: 25258 Btuh 100% of load Latent capacity: 9342 Btuh 193% of load Total capacity: 34600 Btuh 115% of load SHR: 73% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 26633 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox or Eqv. Model: 14HPX-036-230-19+CBX25UHV-036-230-` Actual airflow: 0 cfm Output capacity: 34000 Btuh 128% of load Capacity balance: 25 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 10.0 kW 128% of load Temp. rise: 27 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Mar-23 18:01:59 wrightsoft Right-Suite®Universal 2015 15.0.21 RSU07440 Page 1 ACCN ...ork File\R0316112-967 Camelia St\R0316112.rup Calc=MJ8 House Front faces: W Project SummaryJob: R0316112 + - wrightsoftDate: 03-23-16 Entire House By: JND Solar Home Developers, LLC 2425 Bentshire Dr,Jacksonville.FL 32246 Phone:904-472-1459 Pro'ect Information For: Miller Residence 967 Camelia St,Atlantic Beach, FL 32233 Notes: Load Calculation was obtained from an electronic copy of drawing. Desi. n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 51 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21238 Btuh Structure 17696 Btuh Ducts 3005 Btuh Ducts 7462 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24243 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25158 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3092 Btuh Ducts 1758 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1630 1630 Equipment latent load 4850 Btuh Volume(ft3) 15223 15223 Air changes/hour 0.50 0.26 Equipment total load 30008 Btuh Equiv.AVF (cfm) 127 66 Req. total capacity at 0.73 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox or Eqv. Make Lennox or Eqv. Trade Split HP Trade Split HP Model 14HPX-036-230-19 Cond 14HPX-036-230-19 AHRI ref 7044409 Coil CBX25UHV-036-230-° AHRI ref 7044409 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 25258 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 9342 Btuh Temperature rise 0 °F Total cooling 34600 Btuh Actual air flow 0 cfm Actual air flow 1153 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.84 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4 wrightsoft 2016-Mar-2318:01:59 9 Right-Suite8 universal 2015 15.0.21 RSu07440 Page 1 ACCP ...ork File\R0316112-967 Camelia St1R0316112.rup Calc=MJ8 House Front faces: W 4 wrightsoft Right-J® Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC 2425 Bentshire Dr.Jacksonville,FL 32246 Phone:904-472-1459 1 Room name Entire House HBath 2 Exposed wall 214.7 ft 14.7 ft 3 Room height 9.3 ft d 19.2 ft heat/cool 4 Room dimensions 7.7 x 7.0 ft 5 Room area 1630.5 ft' 53.7 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btub/ft'-°F) (BtulVft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 3.41 2.29 678 618 2109 1417 174 168 573 385 G 4A5-2ob 0.290 n 10.88 7.88 6 0 65 47 6 0 65 47 G 4A5-2ob 0.290 n 10.88 7.88 12 0 131 95 0 0 0 0 -G 4A5-2cb 0.290 n 10.88 7.88 12 0 131 95 0 0 0 0 11 -C' 4A5-2ob 0.290 n 10.88 7.88 30 0 326 236 0 0 0 0 W 12C-Osw 0.091 e 3.41 2.29 540 454 1550 1042 0 0 0 0 G 10D-b 0.290 a 10.88 6.68 40 35 431 265 0 0 0 0 -G 4A5-2ob 0.290 e 10.88 21.93 6 0 65 132 0 0 0 0 -G 4A5-2ob 0.290 e 10.88 21.93 40 0 435 877 0 0 0 0 W 12C-Osw 0.091 s 3.41 229 501 465 1587 1066 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 7.88 8 8 87 63 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 4 0 44 38 0 0 0 0 G 4A5-2ob 0.290 s 10,88 9.51 9 0 98 86 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 15 0 163 143 0 0 0 0 W 12C-Osw 0.091 w 3.41 2.29 378 289 986 663 123 108 369 248 4A5-2ob 0.290 w 10.88 21.93 24 0 261 526 0 0 0 0 4A5-2ob 0.290 w 10.88 21.93 30 0 326 658 0 0 0 0 4A5-2ob 0.290 w 10.88 10.98 15 12 163 165 15 12 163 165 D 11NO 0.350 w 13.13 10.57 20 20 264 212 0 0 0 0 P 12C-Osw 0.091 - 3.41 1.39 321 301 1028 420 0 0 0 0 LD 11NO 0.350 n 13.13 10.57 20 20 264 212 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 1034 1034 1241 1777 61 61 73 105 F 20P-19c 0.050 - 1.88 0.68 378 378 708 259 0 0 0 0 F 22A-cd 0.989 - 37.09 0.00 656 96 3548 0 54 15 544 0 6 c)AED excursion 0 182 Envelope loss/gain 16011 10493 1787 1132 12 a) Infiltration 5227 1283 740 182 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 5000 0 Subtotal(lines 6 to 13) 21238 17696 2528 1314 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 106 28 14 Subtotal 21238 17696 2633 1342 15 Duct loads 14% 42% 3005 7462 14% 42% 373 566 Total room load 24243 25158 3006 1908 Air required(cfm) 0 1153 0 87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2016-Mar-23 18:01:59 ACCP• 9 Right-Suite®Universal 2015 15.0.21 RSU07440 Page 1 ...ork File\R0316112-967 Camelia St1R0316112.rup Calc=MJ8 House Front faces: W 4 wrightsoft Right-J®Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC 2425 Bentshire Dr.Jacksonville,FL 32246 Phone:904-472-1459 1 Room name Great Rm Kitchen Dining 2 Exposed wall 38.7 ft 36.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 325.4 ft 1.0 x 238.4 ft 5 Room area 325.4 ft' 238.4 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'`F) (BtutVft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 612C-Osw 0.091 n 3.41 229 171 147 502 337 39 39 133 89 G 4A 2ab 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 4A5lob 0.290 n 10.88 7.88 12 0 131 95 0 0 0 0 0 4A5-2c 0.290 n 10.88 7.68 12 0 131 95 0 0 0 11 G 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 e 3.41 2.29 138 98 336 226 132 92 314 211 G 10D-b 0.290 e 10.88 6.68 40 35 431 265 0 0 0 0 -G 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 40 0 435 877 W 12C-Osw 0.091 s 3.41 2.29 0 0 0 0 153 144 491 330 -G 4A5-2ob 0.290 s 10.88 7.88 0 0 0 0 0 0 0 0 G- 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 9 0 98 86 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 3.41 2.29 39 19 64 43 0 0 0 0 4A 5 tab 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-lob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 w 10.88 10.98 0 0 0 0 0 0 0 0 D 11NO 0.350 w 13.13 10.57 20 20 264 212 0 0 0 0 P 12C-Osw 0.091 - 3.41 1.39 189 169 578 236 132 132 450 184 L-D 11NO 0.350 n 13.13 10.57 20 20 264 212 0 0 0 0 C 168-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 F 20P-198 0.050 - 1.88 0.68 0 0 0 0 0 0 0 0 F 22A-cd 0.989 - 37.09 0.00 325 39 1434 0 238 36 1335 0 6 c)AED excursion -220 -51 Envelope loss/gain 4133 1501 3257 1727 12 a) Infiltration 867 213 808 198 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 1900 Subtotal(lines 6 to 13) 5001 2913 4064 3825 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 466 126 0 0 14 Subtotal 5467 3039 4064 3825 15 Duct loads 14% 42% 774 1282 14% 42% 575 1613 Total room load 6240 4320 4640 5438 Air required(cfm) 0 198 0 249 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2016-Mar-2318:01:59 Aar -A 9 Right-Suite®Universal 2015 15.0.21 RSU07440 Page 2 ..ork File\R0316112-967 Camelia St\R0316112.rup Calc=MJ8 House Front faces. W 4 wrightsoft Right-J®Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC 2425 Bentshire Dr,Jacksonville, FL 32246 Phone:904-472-1459 1 Room name Master Bedroom Mwic 2 Exposed wall 28.0 ft 5.0 ft 3 Room height 9.0 ft heat/cod 9.0 ft heat/cool 4 Room dimensions 15.3 x 12.7 ft 5.7 x 5.0 ft 5 Room area 194.2 ft' 28.3 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw 0.091 n 3.41 2.29 114 84 287 193 45 45 154 103 G 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 11 G 4A5-2ob 0.290 n 10.88 7.88 30 0 326 236 0 0 0 0 W 12C-Osw 0.091 e 3.41 2.29 138 138 471 316 0 0 0 0 G 10D-b 0.290 e 10.88 6.68 0 0 0 0 0 0 0 0 G 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 3.41 2.29 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 7.88 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 0 0 0 0 Or) 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 w 10.88 10.98 0 0 0 0 0 0 0 0 11NO 0.350 w 13.13 10.57 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 LD 11NO 0.350 n 13.13 10.57 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 194 194 233 334 28 28 34 49 F 20P-19c 0.050 - 1.88 0.68 0 0 0 0 0 0 0 0 F 22A-cd 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -154 -13 Envelope loss/gain 1317 925 188 • 139 12 a) Infiltration 628 154 112 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 1945 2039 300 167 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1945 2039 300 167 15 Duct loads 14% 42% 275 860 14% 42% 42 70 Total room load 2220 2899 342 237 Air required(cfm) 0 133 0 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2016-Mar-23 18:01:59 .�A Right-Suite. Universal 2015 15.0.21 RSU07440 Page 3 ...ork File\R0316112-967 Camelia St\R0316112.rup Calc=MJ8 House Front faces: W 4 wrightsoft Right-J®Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC 2425 Bentshire Dr,Jacksonville.FL 32246 Phone:904-472-1459 1 Room name Laundry Loft 2 Exposed wall 0 ft 11.7 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.0 x 8.0 ft 1.0 x 169.7 ft 5 Room area 48.0 ft' 169.7 ft' Ty Construction U-value Or HTM Area (ftp) Load Area (ft') Load number (Btuh/ft'-°F) (Btuhrft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw 0.091 n 3.41 229 0 0 0 0 21 21 72 48 . 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 11 G 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 12C-Osw 0.091 e 3.41 2.29 0 0 0 0 0 0 0 0 G 10D-b 0.290 e 10.88 6.68 0 0 0 0 0 0 0 0 I-CG' 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 3.41 2.29 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 5 10.88 7.88 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 5 10.88 9.51 0 0 0 0 0 0 0 0 WI 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 84 60 205 138 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 24 0 261 526 4A 5-2ob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 w 10.88 10.98 0 0 0 0 0 0 0 0 11N 0.350 w 13.13 10.57 0 0 0 0 0 0 0 0 Pi12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 I-D 11 N O 0.350 n 13.13 10.57 0 0 0 0 0 0 0 0 C 166-30ad 0.032 - 1.20 1.72 48 48 58 82 170 170 204 292 F 20P-19c 0.050 - 1.88 0.68 0 0 0 0 83 83 156 57 F 22A-cd 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -41 205 Envelope loss/gain 58 42 897 1265 12 a) Infiltration 0 0 262 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 0 Subtotal(lines 6 to 13) 58 542 1159 1330 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 58 542 1159 1330 15 Duct loads 14% 42% 8 228 14% 42% 164 561 Total room load 66 770 1323 1890 Air required(cfm) 0 35 0 87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr- ht50f't 2016-Mar-2318:01:59 _Aar 9 Right-Suite®Universal 2015 15.0.21 RSU07440 Page 4 ...ork File\R0316112-967 Camelia St1R0316112.rup Calc=MJ8 House Front faces: W 4 wrightsoft Right-J®Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC 2425 Bentshire Dr,Jacksonville,FL 32246 Phone:904-472-1459 1 Room name MBath Mwic2 2 Exposed wall 8.3 ft 10.7 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 14.7 x 6.0 ft 6.3 x 4.7 ft 5 Room area 88.0 ft' 29.6 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-`'F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw 0.091 n 3.41 2.29 0 0 0 0 39 39 133 89 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 . 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 11 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 bG12C-Osw 0.091 e 3.41 2.29 21 21 72 48 57 57 195 131 10D-b 0.290 e 10.88 6.68 0 0 0 0 0 0 0 0 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 3.41 2.29 54 46 157 105 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 7.88 8 6 87 63 0 0 0 0 C- 4A5-2ab 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 0 0 0 0 4A5lob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A 5-2ob 0.290 w 10.88 10.98 0 0 0 0 0 0 0 0 11N 0.350 w 13.13 10.57 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 Pi 11 N 0 0.350 n 13.13 10.57 0 0 0 0 0 0 0 0 C 16B-30ad 0 032 - 1.20 1.72 88 88 106 151 30 30 35 51 F 20P-19c 0.050 - 1.88 0.68 0 0 0 0 0 0 0 0 F 22A-col 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -14 -23 Envelope loss/gain 421 354 363 248 12 a) Infiltration 187 46 239 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 200 0 Subtotal(lines 6 to 13) 608 600 602 307 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 608 600 602 307 15 Duct loads 14% 42% 86 253 14% 42% 85 129 Total room load 694 853 688 436 Air required(cfm) 0 39 0 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Mar-23 1 ACCAr wrightsoft Right-Suites Universal 2015 15.0.21 RSU07440 Page 55 _.ork File\R0316112-967 Camelia St\R0316112.rup Calc=MJ8 House Front faces: W a 4 wrightsoft Right-J®Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC 2425 Bentshire Dr.Jacksonville.FL 32246 Phone:904-472-1459 1 Room name Mtlt Bedroom2 2 Exposed wall 10.7 ft 10.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.0 x 4.7 ft 1.0 x 141.2 ft 5 Room area 28.0 ft' 141.2 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'--°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 3.41 2.29 0 0 0 0 0 0 0 0 G 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 -G 4A5.2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 11 G 4A 5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 VJ 12C-Osw 0.091 e 3.41 2.29 54 48 164 110 0 0 0 0 G 10D-b 0.290 e 10.88 6.68 0 0 0 0 0 0 0 0 G 4A5-2ob 0.290 e 10.88 21.93 6 0 65 132 0 0 0 0 -G 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 3.41 2.29 42 42 143 96 90 75 256 172 -G 4A5-2ob 0.290 s 10.88 7.88 0 0 0 0 0 0 0 0 --G 4A 5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 G 4A5.2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 -G 4A 5-2cb 0.290 s 1088 9.51 0 0 0 0 15 0 163 143 IW 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 0 0 0 0 4A 5 lob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A 5.205 0.290 w 10.88 10.98 0 0 0 0 0 0 0 0 D 11N O 0.350 w 13.13 10.57 0 0 0 0 0 0 0 0 Pi 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 Pi 11 N O 0.350 n 13.13 10.57 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 28 28 34 48 141 141 169 243 F 20P-19c 0.050 - 1.88 0.68 0 0 0 0 48 48 91 33 F 22A-cd 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 14 -42 Envelope loss/gain 406 400 679 548 12 a) Infiltration 239 59 224 55 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 250 Subtotal(lines 6 to 13) 645 458 903 1083 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 645 458 903 1083 15 Duct loads 14% 42% 91 193 14% 42% 128 457 Total room load 737 652 1031 1540 Air required(cfm) 0 30 0 71 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr- htsoft 2016-Mar-2318:01:59 A 9 Right-Suites Universal 2015 15.0.21 RSU07440 Page 6 ...ork File\R0316112-967 Camelia St\R0316112.rup Calc=MJ8 House Front faces: W -4- wrightsoft Right-J®Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC 2425 Bentshire Dr.Jacksonville,FL 32246 Phone:904-472-1459 1 Room name Bath2 Bedroom3 2 Exposed wall 5.7 ft 29.0 ft 3 Room height 9 0 ft heavcool 9.0 ft heat/cool 4 Room dimensions 1.0 x 65.3 ft 14.8 x 12.3 ft 5 Room area 65 3 ft' 181.9 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/f12) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 612C-Osw 0.091 n 3.41 2.29 0 0 0 0 18 18 61 41 G 4A5-2ob n 10.88 7.88 0 0 0 0 0 0 0 0 G 4AS2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 0 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 11 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 e 3.41 2.29 0 0 0 0 0 0 0 0 G 10D-b 0.290 e 10.88 6.68 0 0 0 0 0 0 0 0 G 4A5-2ob 0.290 a 10.88 21.93 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 s 3.41 2.29 51 47 160 108 111 111 379 255 -G 4A5-2ob 0.290 s 10.88 7.88 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 5 10.88 9.51 4 0 44 38 0 0 0 0 G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 0 0 0 0 IW 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 132 102 348 234 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 0 0 0 0 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 30 0 326 658 4A5-2ob 0.290 w 10.88 10.98 0 0 0 0 0 0 0 0 D 11NO 0.350 w 13.13 10.57 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 Pi 11NO 0.350 n 13.13 10.57 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 65 65 78 112 181 181 217 311 F 20P-19c 0.050 - 1.88 0.68 65 65 122 45 181 181 339 124 F 22A-col 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -28 196 Envelope loss/gain 405 275 1671 1818 12 a) Infiltration 127 31 651 160 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 200 250 Subtotal(lines 6 to 13) 532 506 2321 2458 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 532 506 2321 2458 15 Duct loads 14% 42% 75 214 14% 42% 328 1036 Total room load 607 720 2650 3494 Air required(cfm) 0 33 0 160 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' .!`. r- ht soft 2016-Mar-2318:01:59 AATwg Right-Suite`f)Universal 2015 15.0.21 RSU07440 Page 7 ...ork File1R0316112-967 Camelia St1R0316112.rup Calc=MJ8 House Front faces. W 4 wrightsoft Right-J®Worksheet Job: R0316112 Entire House Date: 03-23-16 By: JND Solar Home Developers, LLC il 2425 Bentshire Dr,Jacksonville,FL 32246 Phone:904-472-1459 1 Room name Stairs 2 Exposed wall 6.3 ft 3 Room height 9.0 ft heat/cool 4 Room dimensions 1.0 x 38.8 ft 5 Room area 38.8 W Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ft'°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter 0 Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12C-Osw 0.091 n 3.41 2.29 57 57 195 131 4A 5-2ab 0.290 n 10.88 7.88 0 0 0 0 . 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 11 G 4A5-2ob 0.290 n 10.88 7.88 0 0 0 0 12C-Osw 0.091 e 3.41 229 0 0 0 0 10D-b 0.290 e 10.88 6.68 0 0 0 0 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 4A5-2ob 0.290 e 10.88 21.93 0 0 0 0 W 12C-Osw 0.091 s 3.41 2.29 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 7.88 0 0 0 0 -3 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 G 4A5-2cb 0.290 s 10.88 9.51 0 0 0 0 -G 4A5-2ob 0.290 s 10.88 9.51 0 0 0 0 WI 12C-Osw 0.091 w 3.41 2.29 0 0 0 0 4A5-2ob0.290 w 10.88 21.93 0 0 0 0 4A5-2ob 0.290 w 10.88 21.93 0 0 0 0 4A5-2ob 0.290 w 10.88 10.98 0 0 0 0 D 11NO 0.350 w 13.13 10.57 0 0 0 0 P12C-Osw 0.091 - 3.41 1.39 0 0 0 0 LD 11NO 0.350 n 13.13 10.57 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 F 20P-19c 0.050 - 1.88 0.68 0 0 0 0 F 22A-col 0.989 - 37.09 0.00 39 6 235 0 6 c)AED excursion -12 Envelope loss/gain 429 119 12 a) Infiltration 142 35 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 571 154 Less external load 0 0 Less transfer 0 0 Redistribution -571 -154 14 Subtotal 0 0 15 Duct loads 14% 42% 0 0 Total room load 0 0 Air required(cfm) 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft 2016-Mar-23 18:01:59 AZ-6A 9 Right-Suite Universal 2015 15.0.21 RSU07440 Page 8 ...ork File1R0316112-967 Camelia St\R0316112.rup Calc=MJ8 House Front faces. W 1