1955 Beachside Ct HVAC permit CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
'�- INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
lob ID: 16-MECH-2507
lob Type: MECHANICAL HVAC ONLY
Description: replace 3.0-ton 36K-BTU AHU
Estimated Value: $6,702.00
Issue Date: 11/8/2016
Expiration_Date: 5/7/2017
PROPERTY ADDRESS:
Address: 1955 BEACHSIDE CT
RE Number: 169542-0580
PROPERTY OWNER:
Name: JURASIC, MATEOAND MARGAUX, '
Address: 1955 BEACHSIDE CT
GENERAL CONTRACTOR INFORMATION:
Name: SERVICE EXPERTS
Carey L.Zarm,CAC1817129
Address: 8475 WESTERN WAY STE 100 QA CAREY ZARM
Phone: -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
AC and Refrigeration $24.00
Furnaces and Heating $20.00
State Mach DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $103.00
PERMIT IS APPROVED ONLY LN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Q, ,qPh(904)2'4/7-5826 Fax(904)247-5845 1�—M (f —aSb�
IOB ADDRESS: ! S V S . PACN S 1 .OrP PERMIT#
PROJECT VALUE $ 6 70ARI# 76 ,� �/SSD REQUIRED
_Air Handling Equipment Only _ it Handling Unit & Condenser —Condenser
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity / Tons Per Unit 3 D
Heat: Unit Quantity BTU's Per Unitb U a Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace QtyAutomobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
tis application and know the same to be one and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
at. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Mh TP O .TLl/L /Y CI C Phone Number
Mechanical Company Service Experts Office Phone 271-2182 Fax
Co.Address: 8475 Western Way Suite 100 City Jacksonville State Fi_Zip 32256
License Holder(Print): Carey Zarm tate Certificat:on/Registration#CAC 1817129
Notarized Signature of License Holder M 4 —
cnsotaurrss<rn Before me this 7TEday of O 20 _
s+; ;ia� MY SSIIXU FF0
Notary Public /.
O EXPIRES JWy s,201
8 Signature of
`tT
mmaatnNxm.nv�eieuxwnt.rs