1545 MAIN ST - AT & T RADIO DWGS r„,_\i,J,,
s, CITY OF ATLANTIC BEACH
, 2
r, w< _,:„„ ” :) 800 SEMINOLE ROAD
j " ATLANTIC BEACH, FL 32233
/ INSPECTION PHONE LINE 247-5814
COMMERICAL ALTERATION/OTHER
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 16-COTH-2315
Job Type: COMMERCIAL OTHER
Description: Ansco & Associates LLC for AT&T - AT&T 5C installing 3
antennas, 3 RRUS-32 B 66, 2 DC2, 1 DC6, power and fiber cables.
Estimated Value: $20,000.00
Issue Date: 10/24/2016
Expiration Date: 4/22/201.7
PROPERTY ADDRESS:
Address: 1545 MAIN ST
RE Number: 172325-0000
PROPERTY OWNER:
Name: PAR PRO LTD
Address: P 0 BOX 330177
GENERAL CONTRACTOR INFORMATION:
Name: Ansco & Associates
Jack Michael Hober, CGC1522785
Address: 735 Park N Blvd BLVD
Phone: - -
PERMIT INFORMATION:
FEES:
Total Payments: $0.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
e
Mir
A4. P- n BUILDING PERMIT APPLICATION
CITY OF ATLANTIC BEACH
J 800 Seminole Road,Atlantic Beach FL 32233
Office:(904)247-5826 • Fax:(904)247-5845
Job Address: 1545 Main Street,Atlantic Beach,FL 32233 1 _(../ �u _�315-
17-2S-29E 5.71
Permit Number: 1 hl .0 rl
Legal Description PT GOVT I OT 4 RECD O/R 11544.628 RE# 172325-0000
Valuation of Work(Replacement Cost)$ 20,000 Heated/Cooled SF Non-Heated/Cooled
• Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door
• Use of existing/proposed structure(s)(Circle one): Commercial Residential
• If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal
Describe in detail the type of work to be performed:
AT&T 5C installing 3 antennas,3 RRUS-32 B 66,2 DC2, 1 DC6,power and
fiber cables.
Florida Product Approval# for multiple products use product approval form
Property Owner Information
Name: Crown Castle South LLC for AT&T Address: 4511 N.Nimes Ave.,Suite 210
City Tampa State FL Zip 33614 Phone 813-342-3852
E-Mail Donna.Moore@crowncastle.com
Owner or Agent (If Agent,Power of Attorney or Agency Letter Required)_
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT.
Contractor Information:
Name of Company: Ansco&Associates LLC Qualifying Agent: Jack Michael Hober
Address: 736 Park North Blvd.,Suite 100 City Clarkston State Zip GA 30021
Office Phone 404-300-5227 Job Site/Contact Number 813-342-3852
State Certification/Registration# CGC1522785 E-Mail Donna.Moore@crowncastle.com
Architect Name& Phone#
Engineer's Name&Phone#
Worker's Compensation Liberty Mutual Fire Ins.Co./Liberty Ins.Co. Exp.7/31/17
Exempt / Insurer / Lease Employees / Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced
rior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdictio
his permit becomes null and void if work is not commenced within sir(6)months, or if construction or work is sus ended or abandoned fo.
period ojsix(6 months at any time after work is commenced. /understand that separate permits must be secures - . rival IV• Phumb
Signs,►Yells,Pools,Furnaces,Boilers,Heaters, Tanks and Air Conditioners,etc.
Signature of Property Owner:�� - Signature of Contracto , / A
Before me
this 25i Day of �� � 7-01k,p Before me this Day of ' t t I ..i4/lo
NotaryPublic: P . / ' •• I .;°.'1;.
t '
t...ii�L/.. �� G O F * 1
NotaryPublic ��' . o ti ��
V
I hereby certify that I have read and examined this application and know the same to he true and correct. All pri»i. kc„/ja •7/ti _ F.
•
ordinances governing this type of work will be complied with whether specified herein or not. The granting oFr I.iiie tt Q
presume to give authority to violate or cancel the provisions of any other federal, state, or local law regulating J tK nor thcc w•:0
performance of construction. •• A
DONNA R MOORE Rev.AVIV,
V ♦
? 4iu •-
Commission#FF 123162 '//,tiN'illi' ; -' %%
I* i „*E My Commission Expires
47-O,Os'
IC Jam, May 14, 2018
PAUFRD Syeaes-
„9
RIF & COMPANYO1962015
Date: August 17, 2016
Angela Harris Paul J Ford and Company
Crown Castle 250 E. Broad Street Suite 600
12725 Morris Road Extension Suite 400 Columbus, OH 43215
Alpharetta, GA 30004 mbuske@pjfweb.com
Subject: Structural Analysis Report
Carrier Designation: AT&T Mobility Co-Locate
Carrier Site Number: 10020470
Carrier Site Name: Mayport
Crown Castle Designation: Crown Castle BU Number: 812565
Crown Castle Site Name: MAYPORT
Crown Castle JDE Job Number: 391746
Crown Castle Work Order Number: 1284708
Crown Castle Application Number: 358493 Rev. 0
Engineering Firm Designation: Paul J Ford and Company Project Number: 37516-1744.002.8700
Site Data: 1545 Main Street, Atlantic Beach, Duval County, FL
Latitude 30°20'13", Longitude -81°25'12"
190 Foot-Self Support Tower
Dear Angela Harris,
Paul J Ford and Company is pleased to submit this "Structural Analysis Report” to determine the structural
integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle
Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 936351, in accordance
with application 358493, revision 0.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC7: Existing + Reserved + Proposed Equipment Sufficient Capacity
Note:See Table I and Table II for the proposed and existing/reserved loading, respectively.
This analysis has been performed in accordance with the 2014 Florida Building Code, 5th Edition, based upon
an ultimate 3-second gust wind speed of 129 mph converted to a nominal 3-second gust wind speed of 100 mph
per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1440
Exposure Category C with a topographic category 1 and crest height of 0 feet, and Risk Category II were u
in this analysis.
)1°' .
We at Paul J Ford and Company appreciate the opportunity of providing our continuing professional services to
you and Crown Castle. If you have any questions or need further assistance on this or any other projects,
please give us a call.
Respectfully submitted by: ;F
No. 79560
* _
Matthew Buske, E.I. � ��.� STATE OF '�
Structural Designer �i A.. ,OH,: ' '��111
��
11 tie
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 3
1) INTRODUCTION
This tower is a 190 ft Self Support tower designed by Rohn in November of 1990. The tower was originally
designed for a wind speed of 100 mph per EIA-222-D. The tower was reinforced by modifications designed by
PJF in July of 2011.
2) ANALYSIS CRITERIA
The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G
Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind
speed of 99.9 mph with no ice, 30 mph with 0 inch ice thickness and 60 mph under service loads, exposure
category C with topographic category 1 and crest height of 0 feet.
Table 1 - Proposed Antenna and Cable Information
Center Number Number Feed
Mounting Line Antenna
of Antenna Model of Feed Line Note
Level (ft) Elevation Antennas Manufacturer Lines Size (in)
(ft)
• 3 commscope SBJAH4-1D65B-DL
2 commscope WCS-IMFQ-AMT-43
3 ericsson RRUS 32 B2 1 3/4
187.0 187.0
3 ericsson RRUS 32 B66 1 3/8
6 raycap DC2-48-60-0-9E
I 1 I raycap DC6-48-60-18-8C
•
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
' Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 5
3) ANALYSIS PROCEDURE
Table 3 -Documents Provided
Document Remarks Reference Source
!
GEOTECHNICAL REPORTS ATEC, #72-01065, 12/3/1990 111139 CCISITES
TOWER FOUNDATION - 816089 CCISITES
DRAWINGS/DESIGN/SPECS
TOWER MANUFACTURER Rohn, #25703JC, 11/30/1990 225932 CCISITES
DRAWINGS
POST-MODIFICATION TEP, #113297, 1/12/2012 3062154 CCISITES
INSPECTION
TOWER REINFORCEMENT PJF,#37511-1230, 7/5/2011 3009343 CCISITES
DESIGN/DRAWINGS/DATA
3.1) Analysis Method
tnxTower(version 7.0.5.1), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built in accordance with the manufacturer's specifications.
2) The tower and structures have been maintained in accordance with the manufacturer's
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
This analysis may be affected if any assumptions are not valid or have been made in error. Paul J
Ford and Company should be notified to determine the effect on the structural integrity of the tower.
4)ANALYSIS RESULTS
Table 4-Section Capacity (Summary)
Section Elevation(ft) Component Type Size Critical P(K) SF"P allow % Pass/Fail
No. Element (K) Capacity
Ti 190-180 Leg Pipe 2.875"S).276"(2.5 2 -3.28 74.51 4.4 Pass
T2 180-160 Leg Pipe 3.5"x 0.300"(3 XS) 29 -29.76 94.46 31.5 Pass
. T3 160-140 Leg Pipe 4.5"x 0.337"(4 XS) 68 -60.15 159.90 37.6 Pass
T4 140-120 Leg Pipe 5.563"x 0.375"(5 107 -89.55 239.38 37.4 Pass
XS)
T5 120-100 Leg Pipe 6.6 EHS)0.340 (6 146 -118.19 244.02 48.4 Pass
•. T6 100-80 Leg Pipe 6.62XS)0.432"(6 173 -149.29 303.62 49.2 Pass
T7 80-60 Leg Pipe 6.62XS)0.432"(6 200 -177.75 303.58 58.5 Pass
T8 60-40 Leg Pipe 8.62EHS)0.375"(8 227 -205.50 386.31 53.2 Pass
T9 40-20 Leg Pipe 8.62EHS) 375 (8 254 233.52 386.31 60.4 Pass
T10 20-0 I Leg I Pipe 8.62XS)) l 0.500"(8 281 I -247.49 I 505.43 I 49.0 I Pass
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 7
Section Elevation(ft) Component Type Size Critical P(K) SF*P allow % Pass/Fail
No. Element (K) Capacity
T9 40-20 Inner Bracing I L3 1/2x3 1/2x114 267 I -0.01 I 8.92 0.2 I Pass
T10 20-0 Inner Bracing Pipe 2.3 STD)0.154 (2 310 -0.01 6.59 0.2 Pass
Summary
Leg(T9) 60.4 Pass
Diagonal 73.8 Pass
(T4)
Horizontal 65.4 Pass
(T10)
Top Girt 3.8 Pass
(T1)
Redund
Horz 1 33.3 Pass
Bracing
(T10)
Redund
• Diag 1 43.6 Pass
Bracing
(T10)
Redund Hip
1 Bracing 0.4 Pass
(T10)
Redund Hip
Diagonal 1 0.5 Pass
Bracing
(T10)
Inner
Bracing 0.3 Pass
(T5)
I I I I I (Bolt Checks I 48.4 I Pass
Rating= 73.8 Pass
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 9
APPENDIX A
TNXTOWER OUTPUT
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 11
•
Wind 180
1
IegA
Wind 90
Q coB
ALeg C Leg B
i 1
Face C
Wind Normal
Triangular Tower
Tower Section Geometry
Tower Tower Assembly Description Section Number Section
Section Elevation Database Width of Length
Sections
ft ft ft
T1 190.00-180.00 8.50 1 10.00
T2 180.00-160.00 8.54 1 20.00
T3 160.00-140.00 8.63 1 20.00
T4 140.00-120.00 10.71 1 20.00
T5 120.00-100.00 12.79 1 20.00
T6 100.00-80.00 15.04 1 20.00
17 80.00-60.00 17.54 1 20.00
T8 60.00-40.00 20.18 1 20.00
T9 40.00-20.00 22.68 1 20.00
T10 20.00-0.00 25.18 1 20.00
Tower Section Geometry (cont'd)
Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt .
Section Elevation Spacing Type K Brace Horizontals Offset Offset
End
ft ft Panels in in
T1 190.00-180.00 5.00 K Brace Down No Yes 0.0000 0.0000
T2 180.00-160.00 6.67 K Brace Down No Yes 0.0000 0.0000
T3 160.00-140.00 6.67 K Brace Down No Yes 0.0000 0.0000
T4 140.00-120.00 6.67 K Brace Down No Yes 0.0000 0.0000
T5 120.00-100.00 10.00 K Brace Down No Yes 0.0000 0.0000
T6 100.00-80.00 10.00 K Brace Down No Yes 0.0000 0.0000
T7 80.00-60.00 10.00 K Brace Down No Yes 0.0000 0.0000
T8 60.00-40.00 10.00 K Brace Down No Yes 0.0000 0.0000
T9 40.00-20.00 10.00 K Brace Down No Yes 0.0000 0.0000
T10 20.00-0.00 20.00 K1 Down No Yes 0.0000 0.0000
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
' Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 13
Tower Secondary Secondary Horizontal Secondary Inner Bracing Inner Bracing Size Inner Bracing
Elevation Horizontal Type Size Horizontal Type Grade
Grade
ft
T2 180.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
160.00 (50 ksi) (36 ksi)
T3 160.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
140.00 (50 ksi) (36 ksi)
T4 140.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
120.00 (50 ksi) (36 ksi)
T5 120.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
100.00 (50 ksi) (36 ksi)
T6 100.00- Solid Round A572-50 Equal Angle L2 1/2x2 1/2x3/16 A36
80.00 (50 ksi) (36 ksi)
17 80.00-60.00 Solid Round A572-50 Equal Angle L3x3x3/16 A572-50
(50 ksi) (50 ksi)
T8 60.00-40.00 Solid Round A572-50 Equal Angle L3 1/2x3 1/2x1/4 A572-50
(50 ksi) (50 ksi)
T9 40.00-20.00 Solid Round A572-50 Equal Angle L3 1/2x3 1/2x1/4 A572-50
(50 ksi) (50 ksi)
T10 20.00-0.00 Solid Round A572-50 Pipe Pipe 2.375"x 0.154"(2 A618-50
(50 ksi) STD) (50 ksi)
Tower Section Geometry (cont'd)
Tower Redundant Redundant Redundant K Factor
Elevation Bracing Type Size
Grade
ft
T10 20.00- A53-B-35 Horizontal(1) Pipe Pipe 1.9"x 0.145"(1.5 1
0.00 (35 ksi) Diagonal(1) Pipe STD) 1
Hip(1) Pipe Pipe 2.375"x 0.154"(2 1
Hip Diagonal Pipe STD) 1
(1) Pipe 1.9"x 0.145"(1.5
STD)
Pipe 2.875"x 0.203"(2.5
STD)
Tower Section Geometry (cont'd)
Tower Gusset Gusset Gusset GradeAdjust.Factor Adjust. Weight Mu/t. Double Angle Double Angle Double Angle
Elevation Area Thickness A, Factor Stitch Bolt Stitch Bolt Stitch Bolt
(per face) A, Spacing Spacing Spacing
Diagonals Horizontals Redundants
ft ft2 in in in in
T1 190.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
180.00 (36 ksi)
T2 180.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
160.00 (36 ksi)
T3 160.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
140.00 (36 ksi)
T4 140.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
120.00 (36 ksi)
T5 120.00- 0.00 0.3750 A36 1 1 1.1. 0.0000 0.0000 36.0000
100.00 (36 ksi)
T6 100.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
80.00 (36 ksi)
17 80.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
60.00 (36 ksi)
T8 60.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
40.00 (36 ksi)
T9 40.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
20.00 (36 ksi)
T10 20.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
0.00 (36 ksi)
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
• Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 15
Tower Section Geometry (cont'd)
Tower Leg Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short
Elevation Connection Horizontal
ft Type
Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No.
in in in in in in in
T1 190.00- Flange 0.8750 4 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
180.00 A325N A325N A325N A325N A325N A325N A325N
T2 180.00- Flange 0.8750 4 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
160.00 A325N A325N A325N A325N A325N A325N A325N
T3 160.00- Flange 1.0000 4 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
140.00 A325N A325N A325N A325N A325N A325N A325N
T4 140.00- Flange 1.0000 6 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
120.00 A325N A325N A325N A325N A325N A325N A325N
T5 120.00- Flange 1.0000 6 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
100.00 A325N A325N A325N A325N A325N A325N A325N
T6 100.00- Flange 1.0000 6 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
80.00 A325N A325N A325N A325N A325N A325N A325N
17 80.00- Flange 1.0000 8 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
60.00 A325N A325N A325N A325N A325N A325N A325N
T8 60.00- Flange 1.0000 8 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
40.00 A325N A325N A325N A325N A325N A325N A325N
T9 40.00- Flange 1.0000 8 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
20.00 A325N A325N A325N A325N A325N A325N A325N
T10 20.00- Flange 1.0000 10 0.7500 3 0.0000 0 0.0000 0 0.6250 0 0.7500 2 0.6250 0
0.00 A354-BC A325N A325N A325N A325N A325N A325N
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face Allow Component Placement Face Lateral # # Clear Width or Perimete Weight
or Shield Type Offset Offset Per Spacing Diameter r
Leg ft in (Frac FW) Row in in plf
in
**Face C**
LDF4- C No Ar(CaAa) 178.00-0.00 0.0000 -0.47 3 2 0.5200 0.6300 0.15
50A(1/2") 0.5000
LDF4- C No Ar(CaAa) 178.00-0.00 0.0000 -0.47 3 3 0.5200 0.6300 0.15
50A(1/2") 0.5000
9207(5/16") C No Ar(CaAa) 178.00-0.00 0.0000 -0.45 3 3 0.3300 0.3300 0.06
2.5"Conduit C No Ar(CaAa) 178.00-0.00 0.0000 0.45 1 1 2.8730 2.8730 5.53
1.5"flat C No Af(CaAa) 178.00-0.00 0.0000 -0.45 2 2 12.0000 1.5000 1.80
Cable Ladder 1.5000
Rail
**Face A**
LDF7-50A(1- A No Ar(CaAa) 130.00-0.00 0.0000 0.4 10 7 0.5200 1.9800 0.82
5/8") 0.5000
ASU9325TY A No Ar(CaAa) 130.00-0.00 0.0000 0.4 3 3 1.5840 1.5840 1.61
P01(1-3/5")
1.5"flat A No Af(CaAa) 130.00-0.00 0.0000 0.4 2 2 12.0000 1.5000 1.80 •
Cable Ladder 1.5000
Rail
**Face B**
HJ7-50A(1- B No Ar(CaAa) 187.00-0.00 0.0000 0.4 12 1? 0.5200 1.9800 1.04
5/8") 0.5000
ATCB- B No Ar(CaAa) 187.00-0.00 0.0000 0.4 3 3 2.1900 0.3150 0.07
B01(5/16) 0.5000
WR- B No Ar(CaAa) 187.00-0.00 0.0000 0.4 5 5 0.7740 0.7740 0.59
VG86ST-
BRD(3/4)
LDF2-50 B No Ar(CaAa) 187.00-0.00 0.0000 0.4 3 3 0.4400 0.4400 0.08
(3/8"foam)
1.5"flat B No Af(CaAa) 187.00-0.00 0.0000 0.4 2 2 12.0000 1.5000 1.80
Cable Ladder 1.5000
Rail
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CC!BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 17
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustmen Front Side
Leg Lateral
Vert
ft ft ft2 ft2 K
ft "
ft
0.00
WCS-IMFQ-AMT-43 A From Leg 4.00 0.0000 187.00 No Ice 0.55 0.39 0.02
0.00
0.00
WCS-IMFQ-AMT-43 B From Leg 4.00 0.0000 187.00 No Ice 0.55 0.39 0.02
0.00
0.00
RRUS 32 B2 A From Leg 4.00 0.0000 187.00 No Ice 2.73 1.67 0.05
0.00
0.00
RRUS 32 B2 B From Leg 4.00 0.0000 187.00 No Ice 2.73 1.67 0.05
0.00
0.00
RRUS 32 B2 C From Leg 4.00 0.0000 187.00 No Ice 2.73 1.67 0.05
0.00
0.00
(2)DC2-48-60-0-9E A From Leg 4.00 0.0000 187.00 No Ice 0.93 0.56 0.02
0.00
0.00
(2)DC2-48-60-0-9E C From Leg 4.00 0.0000 187.00 No Ice 0.93 0.56 0.02
0.00
0.00
SBJAH4-1 D65B-DL w/ A From Leg 4.00 0.0000 187.00 No Ice 9.47 7.74 0.08
Mount Pipe 0.00
0.00
SBJAH4-1 D65B-DL w/ B From Leg 4.00 0.0000 187.00 No Ice 9.47 7.74 0.08
Mount Pipe 0.00
0.00
SBJAH4-1 D65B-DL w/ C From Leg 4.00 0.0000 187.00 No Ice 9.47 7.74 0.08
Mount Pipe 0.00
0.00
RRUS 32 B66 a4 From Leg 4.00 0.0000 187.00 No Ice 2.74 1.67 0.05
0.00
0.00
RRUS 32 B66 B From Leg 4.00 0.0000 187.00 No Ice 2.74 1.67 0.05
0.00
0.00
RRUS 32 B66 C From Leg 4.00 0.0000 187.00 No Ice 2.74 1.67 0.05
0.00
0.00
(2)DC2-48-60-0-9E B From Leg 4.00 0.0000 187.00 No Ice 0.93 0.56 0.02
0.00
0.00
DC6-48-60-18-8C B From Leg 4.00 0.0000 187.00 No Ice 2.74 2.74 0.03
0.00
0.00
Sector Mount[SM 502-3] C None 0.0000 187.00 No Ice 33.02 33.02 1.67
LLPX310R-V4 w/Mount A From Leg 4.00 0.0000 178.00 No Ice 4.44 2.85 0.04
Pipe 0.00
0.00
Horizon DUO A From Leg 4.00 0.0000 178.00 No Ice 0.47 0.29 0.01
0.00
5.00
nRRHv2 A From Leg 4.00 0.0000 178.00 No Ice 2.49 1.48 0.06
0.00
0.00
JUNCTION BOX A From Leg 4.00 0.0000 178.00 No Ice 0.53 0.27 0.00
0.00
0.00
LLPX310R-V4 w/Mount B From Leg 4.00 0.0000 178.00 No Ice 4.44 2.85 0.04
Pipe 0.00
0.00
Horizon DUO B From Leg 4.00 0.0000 178.00 No Ice 0.47 0.29 0.01
0.00
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 19
Description Face Offset Offsets: Azimuth Placement CAAA C,,AA Weight
or Type Horz Adjustmen Front Side
Leg Lateral
Vert
ft ft ft2 ft2 K
ft °
ft
0.00
6'x 2"Mount Pipe C From Leg 4.00 0.0000 130.00 No Ice 1.43 1.43 0.02
0.00
0.00
FASB w/Mount Pipe A From Leg 4.00 0.0000 130.00 No Ice 13.90 14.69 0.24
0.00
0.00
FASB w/Mount Pipe B From Leg 4.00 0.0000 130.00 No Ice 13.90 14.69 0.24
0.00
0.00
FASB w/Mount Pipe C From Leg 4.00 0.0000 130.00 No Ice 13.90 14.69 0.24
0.00
0.00
Sector Mount[SM 104-3] C None 0.0000 130.00 No Ice 30.02 30.02 0.95
Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
ft ft ft ft2 K
VHLP2-18 A Paraboloid From 4.00 90.0000 178.00 2.17 No Ice 3.72 0.03
w/Shroud(HP) Leg 1.00
5.00
VHLP2-11 B Paraboloid From 4.00 90.0000 178.00 2.17 No Ice 3.72 0.03
w/Shroud(HP) Leg 1.00
6.00
VHLP2-18 C Paraboloid From 4.00 90.0000 178.00 2.17 No Ice 3.72 0.03
w/Shroud(HP) Leg 1.00
5.00
Load Combinations
Comb. Description
No.
1 Dead Only
2 1.2 Dead+1.6 Wind 0 deg-No Ice
3 0.9 Dead+1.6 Wind 0 deg-No Ice
4 1.2 Dead+1.6 Wind 30 deg-No Ice
5 0.9 Dead+1.6 Wind 30 deg-No Ice
6 1.2 Dead+1.6 Wind 60 deg-No Ice
7 0.9 Dead+1.6 Wind 60 deg-No Ice
8 1.2 Dead+1.6 Wind 90 deg-No Ice
9 0.9 Dead+1.6 Wind 90 deg-No Ice
10 1.2 Dead+1.6 Wind 120 deg-No Ice
11 0.9 Dead+1.6 Wind 120 deg-No Ice
12 1.2 Dead+1.6 Wind 150 deg-No Ice
13 0.9 Dead+1.6 Wind 150 deg-No Ice
14 1.2 Dead+1.6 Wind 180 deg-No Ice
15 0.9 Dead+1.6 Wind 180 deg-No Ice
16 1.2 Dead+1.6 Wind 210 deg-No Ice
17 0.9 Dead+1.6 Wind 210 deg-No Ice
18 1.2 Dead+1.6 Wind 240 deg-No Ice
19 0.9 Dead+1.6 Wind 240 deg-No Ice
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CC!BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 21
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. °
T8 60-40 1.154 8 0.1677 0.0177
T9 40-20 0.513 12 0.1079 0.0110
T10 20-0 0.114 20 0.0469 0.0048
Critical Deflections and Radius of Curvature - Design Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ft
190.00 Flash Beacon Lighting 8 12.127 0.5567 0.1019 974791
187.00 (2)E15S09P78 8 11.769 0.5572 0.1013 974791
184.00 VHLP2-11 8 11.410 0.5571 0.1006 828718
183.00 VHLP2-18 8 11.291 0.5569 0.1004 805454
178.00 LLPX310R-V4 w/Mount Pipe 8 10.694 0.5535 0.0990 152700
130.00 ETW200VS12UB 8 5.573 0.4067 0.0560 16291
Bolt Design Data
Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable Criteria
No. Type Grade Of Load per Load Load Ratio
ft in Bolts Bolt K Allowable
K
T1 190 Leg A325N 0.8750 4 0.27 40.59 0.007 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 1.55 12.43 0.125 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 1.62 12.43 0.130 ✓ 1 Bolt Shear
T2 180 Leg A325N 0.8750 4 6.08 40.59 0.150 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 2.75 12.43
0.221 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 2.23 12.43 0.179 ✓ 1 Bolt Shear
T3 160 Leg A325N 1.0000 4 13.20 53.01 0.249 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 2.29 12.43 0.184 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 2.13 12.43
0.172 $/ 1 Bolt Shear
T4 140 Leg A325N 1.0000 6 13.02 53.01 0.246 V 1 Bolt Tension
Diagonal A325N 0.6250 3 3.24 12.431 Bolt Shear
0.261
Horizontal A325N 0.6250 2 3.34 12.43 0.269 ✓ 1 Bolt Shear
T5 120 Leg A325N 1.0000 6 17.40 53.01 0.328 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 3.93 12.43 0.316 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 3.52 12.43
0.283 1' 1 Bolt Shear
T6 100 Leg A325N 1.0000 6 22.08 53.01 0.417 V 1 Bolt Tension
Diagonal A325N 0.6250 3 3.78 12.43 0.304 V 1 Bolt Shear
Horizontal A325N 0.6250 2 3.68 12.43
0.296 V 1 Bolt Shear
T7 80 Leg A325N 1.0000 8 19.68 53.01 0.371 V 1 Bolt Tension
Diagonal A325N 0.6250 3 3.78 12.43 0.304 V 1 Bolt Shear
Horizontal A325N 0.6250 2 3.94 12.43 0.317 ✓ 1 Bolt Shear
T8 60 Leg A325N 1.0000 8 22.66 53.01 0.428 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 4.14 12.43 0.333 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 4.57 12.43 0.368 ✓ 1 Bolt Shear
T9 40 Leg A325N 1.0000 8 25.65 53.01 0.484 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 4.30 12.43 0.346 ✓ 1 Bolt Shear
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 23
Section Elevation Size L L„ KUr A P„ 41P„ Ratio
No. P„
ft ft ft in2 K• K 4)P.
STD) K=1.00 V
T6 100-80 Pipe 3.5"x 0.216"(3 13.31 12.89 132.9 2.2285 -11.34 28.50 0.398'
STD) K=1.00 (/
T7 80-60 Pipe 3.5"x 0.216"(3 14.21 13.82 142.5 2.2285 -11.34 24.78 0.458 1
STD) K=1.00 y/
T8 60-40 Pipe 3.5"x 0.216"(3 15.12 14.64 151.0 2.2285 -12.42 22.07 0.563 1
STD) K=1.00 V
T9 40-20 Pipe 3.5"x 0.216"(3 16.08 15.62 161.1 2.2285 -12.90 19.40 0.665 1
STD) K=1.00 `/
T10 20-0 (37515-2715)2.875"x 24.33 12.17 158.8 3.7615 -19.05 33.70 0.565 1
.276"Pipe w/3.5"x.300" K=1.00 I/
Half Sleeve
P„ /4P0 controls
Horizontal Design Data (Compression)
Section Elevation Size L L„ KUr A P„ •P„ Ratio
No. P.
ft ft ft in2 K K 4)P"
T1 190-180 Pipe 1.9"x 0.145"(1.5 8.52 4.14 79.8 0.7995 -3.20 22.58 0.142'
STD) K=1.00 V
T2 180-160 Pipe 1.9"x 0.145"(1.5 8.60 4.15 80.0 0.7995 -4.42 22.52 0.196'
STD) K=1.00 V
T3 160-140 Pipe 1.9"x 0.145"(1.5 10.01 4.82 92.9 0.7995 -4.27 19.14 0.223'
STD) K=1.00 V
T4 140-120 Pipe 2.375"x 0.154"(2 12.10 5.82 88.7 1.0745 -6.68 27.21 0.245'
STD) K=1.00 y/
T5 120-100 Pipe 2.375"x 0.154"(2 13.92 6.68 101.9 1.0745 -7.04 22.64 0.311 '
STD) K=1.00 V
T6 100-80 Pipe 2.375"x 0.154"(2 16.29 7.87 120.0 1.0745 -7.36 16.86 0.436 1
STD) K=1.00 V
17 80-60 Pipe 2.875"x 0.203"(2.5 18.86 9.15 115.9 1.7040 -7.88 28.64 0.275'
STD) K=1.00 i/
T8 60-40 Pipe 2.875"x 0.203"(2.5 21.43 10.35 131.1 1.7040 -9.05 22.38 0.404'
STD) K=1.00 V
T9 40-20 Pipe 2.875"x 0.203"(2.5 23.93 11.60 147.0 1.7040 -9.76 17.82 0.548 1
STD) K=1.00 (/
T10 20-0 Pipe 2.875"x 0.203"(2.5 25.18 12.23 154.9 1.7040 -10.50 16.05 0.654'
STD) K=1.00 `/
1 P„ /4)P„controls •
Top Girt Design Data (Compression)
Section Elevation Size L L„ KUr A P„ 4P„ Ratio
No. P.
ft ft ft in2 K K 4)P.
T1 190-180 Pipe 1.9"x 0.145"(1.5 8.50 4.13 79.6 0.7995 -0.87 22.63 0.038'
STD) K=1.00 V
1 P„ I 11P„controls
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CC!BU No 812565
' Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 25
Section Elevation Size L L. K!/r A P. 41P„ Ratio
No. P„
ft ft ft in2 K• K Op„
T3 160-140 L2x2x1/8 5.01 5.01 151.1 0.4844 -0.01 4.79 0.001 '
K=1.00 V
T4 140-120 L2x2x1/8 6.05 6.05 182.6 0.4844 -0.01 3.28 0.003'
K=1.00 ✓
T5 120-100 L2x2x1/8 6.96 6.96 210.0 0.4844 -0.01 2.48 0.003'
K=1.00 V
T6 100-80 L2 1/2x2 1/2x3/16 8.15 8.15 197.5 0.9020 -0.01 5.23 0.002
K=1.00 V
17 80-60 L3x3x3/16 9.43 9.43 189.9 1.0900 -0.01 6.83 0.002 1
K=1.00 V.
T8 60-40 L3 1/2x3 1/2x1/4 10.71 10.71 185.2 1.6900 -0.01 11.13 0.001 1
K=1.00 V/
T9 40-20 L3 1/2x3 1/2x1/4 11.96 11.96 206.9 1.6900 -0.01 8.92 0.001
K=1.00 V
T10 20-0 Pipe 2.375"x 0.154"(2 12.59 12.59 191.9 1.0745 -0.01 6.59 0.002 1
STD) K=1.00 V
•
1
P„ /4P„controls
II Tension Checks
Leg Design Data (Tension)
Section Elevation Size L L„ Kir A P. OP„ Ratio
No. P.
11 ft ft ft in2 K K gyp„
T1 190-180 Pipe 2.875"x 0.276"(2.5 10.00 5.00 64.9 2.2535 0.33 101.41 0.003'
XS) V
T2 180-160 Pipe 3.5"x 0.300"(3 XS) 20.00 6.67 70.4 3.0159 24.31 135.72 0.179 1
T3 160-140 Pipe 4.5"x 0.337"(4 XS) 20.04 6.68 54.3 4.4074 52.79 198.34 0.266 1
11 T4 140-120 Pipe 5.563"x 0.375"(5 20.04 6.68 43.6 6.1120 78.11 275.04 0.284 1
XS) ✓
T5 120-100 Pipe 6.625"x 0.340"(6 20.04 10.02 54.0 6.7133 104.43 302.10 0.3461
EHS) V
T6 100-80 Pipe 6.625"x 0.432"(6 20.05 10.03 54.8 8.4049 132.48 378.22 0.3501
XS) V
T7 80-60 Pipe 6.625"x 0.432"(6 20.06 10.03 54.8 8.4049 157.46 378.22 0.416 1
XS) V
T8 60-40 Pipe 8.625"x 0.375"(8 20.05 10.03 41.2 9.7193 181.31 437.37 0.415
EHS) V.
T9 40-20 Pipe 8.625"x 0.375"(8 20.05 10.03 41.2 9.7193 205.17 437.37 0.469 1
EHS) V
T10 20-0 Pipe 8.625"x 0.500"(8 20.05 10.03 41.8 12.762 214.87 574.32 0.374
XS) 7 I,
1 P„ I¢P„controls
Diagonal Design Data (Tension)
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
' Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 27
Section Elevation Size L L„ KUr A Pu OR, Ratio
No. Pu
ft ft ft in2 K• K OPn
T1 190-180 Pipe 1.9"x 0.145"(1.5 8.50 4.13 79.6 0.7995 0.87 35.98 0.024'
STD) V/
1
P u /en controls
Redundant Horizontal (1) Design Data (Tension)
Section Elevation Size L Lu KUr A P. OPn Ratio
No. Pu
ft ft ft in2 K K en
j T10 20-0 Pipe 1.9"x 0.145"(1.5 6.29 5.93 114.4 0.7995 4.29 25.18 0.171 '
STD) V
• 1 P„ /(pPn controls
Redundant Diagonal (1) Design Data (Tension)
Section Elevation Size L Lu KUr A P. 4)Pn Ratio
No. P„
ft ft ft in2 K K OPn
T10 20-0 Pipe 2.375"x 0.154"(2 11.50 10.77 164.2 1.0745 3.92 33.85 0.116'
STD) V
Pu /013n controls
Redundant Hip Diagonal (1) Design Data (Tension)
Section Elevation Size L L„ KUr A Pu 4Pn Ratio
No. Pu
ft ft ft in2 K K en
T10 20-0 Pipe 2.875"x 0.203"(2.5 15.07 15.07 190.9 1.7040 0.08 53.68 0.001 '
STD) {I
1 P u /OPn controls
Inner Bracing Design Data (Tension)
Section Elevation Size L Lu KUr A Pu 4Pn Ratio
No. Pu
ft ft ft in2 K K OPn
T1 190-180 L2x2x1/8 4.25 4.25 81.4 0.4844 0.02 15.69 0.001 1
V/
T2 180-160 L2x2x1/8 4.30 4.30 82.4 0.4844 0.01 15.69 0.000 1
V
T3 160-140 L2x2x1/8 4.31 4.31 82.6 0.4844 0.00 15.69 0.000'
V
T4 140-120 L2x2x1/8 6.05 6.05 115.9 0.4844 0.00 15.69 0.000'
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 29
Section Elevation Component Size Critical P oP,,,o,, % Pass
No. ft Type Element K K Capacity Fail
T3 160-140 Inner Bracing L2x2x1/8 81 -0.01 '4.79 0.1 Pass
T4 140-120 Inner Bracing L2x2x1/8 119 -0.01 3.28 0.3 Pass
T5 120-100 Inner Bracing L2x2x1/8 158 -0.01 2.48 0.3 Pass
T6 100-80 Inner Bracing L2 1/2x2 1/2x3/16 186 -0.01 5.23 0.2 Pass
17 80-60 Inner Bracing L3x3x3/16 212 -0.01 6.83 0.2 Pass
T8 60-40 Inner Bracing L3 1/2x3 1/2x1/4 240 -0.01 11.13 0.2 Pass
T9 40-20 Inner Bracing L3 1/2x3 1/2x1/4 267 -0.01 8.92 0.2 Pass
T10 20-0 Inner Bracing Pipe 2.375"x 0.154"(2 STD) 310 -0.01 6.59 0.2 Pass
Summary
Leg(T9) 60.4 Pass
Diagonal 73.8 Pass
(T4)
Horizontal 65.4 Pass
(T10)
Top Girt 3.8 Pass
(T1)
Redund 33.3 Pass
Horz 1
Bracing
(1i0)
Redund 43.6 Pass
Diag 1
Bracing
(T10)
Redund 0.4 Pass
Hip 1
Bracing
(T10)
Redund 0.5 Pass
Hip
Diagonal 1
li Bracing
(110)
Inner 0.3 Pass
Bracing
i (T5)
Bolt 48.4 Pass
Checks
II RATING= 73.8 Pass
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 31
APPENDIX C
ADDITIONAL CALCULATIONS
tnxTower Report-version 7.0.5.1
190.0 ft-,.. tip I__
. Milli II II
Lel
▪a w - @1 0 ■MI• sr
180.06 s SYMBOL LIST
N liii 11111 MARK SIZE MARK SIZE
eoc / A Pipe 2.875"x 0.277(2.5 XS) F Pipe 2.375"x 0.218"(2 XS)
g ti " B Pipe 5.563"x 0.375"(5 XS) G Pipe 2.875"x 0.203"(2.5 STD)
P,e n N C Pipe 6.625"x 0.340"(6 EHS) H (37515-2715)2.875-x.276"Pipe w/3.5"x.300"
" • i D Pipe 8.625"x 0.500"(8 XS) • Hall Sleeve
n
,"'4 I E Pipe 2.375"x 0.154"(2 STD) I Pipe 1.9"x 0.145"(1.5 STD)
& o
• - 180.0" -- -- MATERIAL STRENGTH
x aGRADE Fy Fu GRADE Fy Fu
er a A618-50 50 ksi 70 ksi A500-46 46 ksi 62 ksi
Q
n -
o
P S m
x e a _ TOWER DESIGN NOTES
°° 1. Tower is located in Duval County,Florida.
N 2. Tower designed for Exposure C to the TIA-222-G Standard.
it.• o - Jas - 140.0 rt 3. Tower designed for a 100 mph basic wind in accordance with the TIA-222-G Standard.
4. Deflections are based upon a 60 mph wind.
5. Tower Structure Class II.
N ■ 6. Topographic Category 1 with Crest Height of 0.00 ft
▪m a "« 1111 i1/1,,,®1I 1111 7. TOWER RATING:73.8%
II i PI
120.0 fl
In a
n
N
r
g 0 V, o « .,......_____ ____.__
K
m M d d d
re N z Z 2
< O
- 2 100.0 fl
o c
ei
•
Brn a ' ^
o80.0 fl •
,_x - --^F- -. _ _ ......
•
N
m
b
G o
'' O
C aA ® 7 ..._.__.
I-I- ei o
W
80.0 fl
o ^ \
x •
.1 c '
/
Cl N `•�
8 \
a
x N
m n /Lu / s.
�'
s. ALL REACTIONS
"' R 40.0 fl ARE FACTORED
. t. C o i 5
N / MAX.CORNER REACTIONS AT BASE:
a N r DOWN: 273 K
B ai. a . - ..../t._._........._.•- SHEAR: 34 K
\ UPLIFT: -238 K
_ 20.0 ft 'N SHEAR: 31 K
•
•
•
• N AXIAL •
i N R 59 K
F o x o - w - w R _...... ..._..
a SHEA MOMENT
58 K 6139 kip-ft
0.0 ft .
TORQUE 29 kip-ft
w REACTIONS-100 mph WIND
H
D "+. o a.e E.
C
a, b 0 a a pp
g•
C .0 C Cg = - = m9C -
aq . .5 $y, m . n 5 dao
le 3 3 5 i5 12 xz rc
cc = : s
• Paul J Ford and Company )ob 190-ft Self Support Tower Atlantic Beach,FL
250 E. Broad Street Suite 600 Projec4'PJF#37516-1744 BU#812565)
Columbus, OH Client Crown Castle DrawnbY:Matthew R Buske App,d:
Phone:43215 Code' TIA-222-G Dale: 8/17/16 Scale: NTS
FAX:614.448.4105 Path:
,.,,,„„M..,,.,,..,07,..,..OM......,v,..,.072,A..1..,,.....wa,Nnw,..nYe*.Dwg No.E-1
Co ,c CO
A-
CS) CO
Co
CI (0 _ i-ii
N ° 111 Q. Y Ya)
III II YQ Y °
N CO 1 co co U)U) c) 0 $ Y
- o e-- 1� . Y Y 0 0 0 Y O ° w
-� '' (V Co �cm- w ° �-0) cA •- Il 0 09 O ,_(...1.
Ili c�0 0 N n 11 II Y 0 0) ') Co � II >
i'� C LL ,- r- O 11 r- O •'4- r Q .° N II
N A II >.N II Ch III v- i., CJ r- C Y 'c (6 O
�' Co a,
Y _ _ _ _ _ -. _.. M c IO C I)0 Co N to co N n
v 2 w ao 0 CO re
N V co O N ow as '� Co O d V +11 i 11 II Co O O N
`� �' O CO
m N N E E = U `) c0
11 O Q)
-r •C C ° +-� U) () E co a) +,, U) U)
co
— N III
15 "C Z _Cf) � CDen 0) 0) 0 UWU) CD
t D E0 E � 'C o o i i5 � D) .n � � 6 0)
O a) L II O - d c C a) a) C N O d a) tv C
.� u! gZ6£ g9 = P m o X = - °- 0 -a c ,_ comb'v
u_ Cr)� - 0 OCL 2D coo » a' CD aa 'a a. a_ m
t
0
Co
a)
m `,
V II
rn
CC
Co 'L V
Q 11g9 m cf)
L - co
o 149 co �
I- z
co s g'o 116 9
o Q I Y
✓'a) '\
;\\ \
Eti �N N
C 3 __
Q
(12 �, C
I III 0)N a) a II —_ 5 - -•-•- -•-• -
M O O • M M \ I —
_ 1 III
CO —
0
11 11 II II II 11 fl - CO
\ M 00 I 0
LL LL N .5 Q a) \ ch 0
t p) a) I- E Y ` \ N 3
0 co
C N _ 0 a) = 1 0
cc ccs) OCL C) II Y IIIA t � ai
ai
,crI-▪ C a) `m ° >0 3 al
O = v — a) t o) E N
oa' a) J• 111— M L � 3 � 0 °'
U a) a) ti % o)(0 O ..)
O 0 a) ° > c — a .0 c co d
i U V 0 ° = U a) O n°(S V
C N C > O
O SZ
M C E _ N * 0 co
O V
C (L •C ca (4 OU p) co r
C
I-
LL >? 4 . C co
o E v 3 °'
to0
0
PAUFORDPJF
& COMPANY 015
Date: August 17, 2016
Angela Harris Paul J Ford and Company
Crown Castle 250 E. Broad Street Suite 600
12725 Morris Road Extension Suite 400 Columbus, OH 43215
Alpharetta, GA 30004 mbuske@pjfweb.com
Subject: Structural Analysis Report
Carrier Designation: AT&T Mobility Co-Locate
Carrier Site Number: 10020470
Carrier Site Name: Mayport
Crown Castle Designation: Crown Castle BU Number: 812565
Crown Castle Site Name: MAYPORT
Crown Castle JDE Job Number: 391746
Crown Castle Work Order Number: 1284708
Crown Castle Application Number: 358493 Rev. 0
Engineering Firm Designation: Paul J Ford and Company Project Number: 37516-1744.002.8700
Site Data: 1545 Main Street, Atlantic Beach, Duval County, FL
Latitude 30°20'13", Longitude -81°25'12"
190 Foot-Self Support Tower
Dear Angela Harris,
Paul J Ford and Company is pleased to submit this "Structural Analysis Report" to determine the structural
integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle
Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 936351, in accordance
with application 358493, revision 0.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:
LC7: Existing + Reserved + Proposed Equipment Sufficient Capacity
Note: See Table I and Table H for the proposed and existing/reserved loading, respectively.
This analysis has been performed in accordance with the 2014 Florida Building Code, 5,h Edition, based upon
an ultimate 3-second gust wind speed of 129 mph converted to a nominal 3-second gust wind speed of 100 mph
per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1.
Exposure Category C with a topographic category 1 and crest height of 0 feet, and Risk Category II were used
in this analysis.
We at Paul J Ford and Company appreciate the opportunity of providing our continuing professional services to
you and Crown Castle. If you have any questions or need further assistance on this or any other projects,.
please give us a call. \ 1.ODD ,��
..CESS •
Respectfully submitted by: " • �
I. No. 79560
Matthew Buske, E.I. 1 STATE OF 1� z-_—
0'
Structural Designer
I 111
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 3
1) INTRODUCTION
This tower is a 190 ft Self Support tower designed by Rohn in November of 1990. The tower was originally
designed for a wind speed of 100 mph per EIA-222-D. The tower was reinforced by modifications designed by
PJF in July of 2011.
2) ANALYSIS CRITERIA
The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G
Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind
speed of 99.9 mph with no ice, 30 mph with 0 inch ice thickness and 60 mph under service loads, exposure
category C with topographic category 1 and crest height of 0 feet.
Table 1 - Proposed Antenna and Cable Information
Center Number Number Feed
Mounting Lineof Antenna Antenna Model of Feed Line Note
Level (ft) Elevation Antennas Manufacturer Lines Size (in)
(ft) - —
3 commscope SBJAH4-1D65B-DL
2 commscope WCS-IMFQ-AMT-43
3 ericsson RRUS 32 B2 1 3/4
187.0 187.0 1 3/8
3 ericsson RRUS 32 B66
6 raycap DC2 48 60 0 9E
1 raycap I DC6-48-60-18-8C
I
tnxTower Report-version 7.0.5.1
J August 17, 2016
190 Ft Self Support Tower Structural Analysis CC!BU No 812565
' Project Number 37516-1744.002.8700,Application 358493,Revision 0 Page 5
3)ANALYSIS PROCEDURE
Table 3-Documents Provided
Document Remarks Reference Source
GEOTECHNICAL REPORTS ATEC, #72-01065, 12/3/1990 111139 CCISITES
TOWER FOUNDATION _ 816089 CCISITES
DRAWINGS/DESIGN/SPECS
TOWER MANUFACTURER
DRAWINGS
POST-MODIFICATION Rohn, #25703JC, 11/30/1990 225932 CCISITES
TEP,#113297, 1/12/2012 3062154 CCISITES
INSPECTION
TOWER REINFORCEMENT I PJF,#37511-1230, 7/5/2011 3009343 I CCISITES
DESIGN/DRAWINGS/DATA
3.1) Analysis Method
tnxTower(version 7.0.5.1), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) Tower and structures were built in accordance with the manufacturer's specifications.
2) The tower and structures have been maintained in accordance with the manufacturer's
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
This analysis may be affected if any assumptions are not valid or have been made in error. Paul J
Ford and Company should be notified to determine the effect on the structural integrity of the tower.
4) ANALYSIS RESULTS
Table 4-Section Capacity (Summary)
Section SF"P allow %
Elevation(ft) Component Type Size Critical P(K) Pass/Fail
No. Element (K) Capacity
Pipe 2.875"x 0.276"(2.5
Ti 190-180 Leg XS) 2 -3.28 74.51 4.4 Pass
T2 180-160 Leg Pipe 3.5"x 0.300"(3 XS) 29 -29.76 94.46 31.5 Pass
T3 160-140 Leg Pipe 4.5"x 0.337"(4 XS) 68 -60.15 159.90 37.6 Pass
T4 140-120 Leg Pipe 5.563"x 0.375"(5 107 -89.55 239.38 37.4 Pass
)
T5 120-100 Leg Pipe 6.625"EHS) 340 (6 146 -118.19 244.02 48.4 Pass
T6 100-80 Leg Pipe 6.625")0.432"(6 173 -149.29 303.62 49.2 Pass
T7 80-60 Leg Pipe 6.625")0.432"(6 200 -177.75 303.58 58.5 Pass
T8 60-40 Leg Pipe 8.62EHS)5"x 375 (8 227 -205.50 386.31 53.2 Pass
T9 40-20 Leg Pipe 8.625"
x) 375 (8 254 -233.52 l 386.31 60.4Ef Pass
! I
T10 { 20-0 Leg I Pipe 8.62X5;0.500"(8 281-247.49 l 505.43 1 49.0 I Pass
tnxTower Report-version 7.0.5.1
•
August 17, 2016
190 Ft Self Support Tower Structural Analysis CC/BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 7
Section Elevation(ft) Component Type Size Critical P(K) SP? allow % pass/Fail
No. Element (K) Capacity
T9 40-20 Inner Bracing L3 1/2x3 1/2x1/4 267 -0.01 8.92 0.2 Pass
T10 20-0 Inner Bracing Pipe 2.375"STD)0.154 (2 310 -0.01 6.59 0.2 Pass
Summary
Leg(T9) 60.4 Pass
Diagonal 73.8 Pass
(T4)
Horizontal 65.4 Pass
(T10)
Top Girt 3.8 Pass
(T1)
Redund
Horz 1 33.3 Pass
Bracing
(T10)
Redund
Diag 1 43.6 Pass
Bracing
(T10)
Redund Hip
1 Bracing 0.4 Pass
(T10)
Redund Hip
Diagonal 1 0.5 Pass
Bracing
(T10)
Inner
Bracing 0.3 Pass
(T5)
Bolt Checks 48.4 Pass
I I I I Rating= I 73.8 Pass
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CC!BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 9
APPENDIX A
TNXTOWER OUTPUT
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 11
•
Wind 180
1
4 Leg A
Wind 90 A
Leg C I. A Leg B
Face C
Wind Normal
Triangular Tower
Tower Section Geometry
Tower Tower Assembly Description Section Number Section
Section Elevation Database Width of Length
Sections
ft ft ft
T1 190.00-180.00 8.50 1 10.00
T2 180.00-160.00 8.54 1 20.00
T3 160.00-140.00 8.63 1 20.00
T4 140.00-120.00 10.71 1 20.00
T5 120.00-100.00 12.79 1 20.00
T6 100.00-80.00 15.04 1 20.00
T7 80.00-60.00 17.54 1 20.00
T8 60.00-40.00 20.18 1 20.00
T9 40.00-20.00 22.68 1 20.00
T10 20.00-0.00 25.18 1 20.00
Tower Section Geometry (cont'd)
Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt .
Section Elevation Spacing Type K Brace Horizontals Offset Offset
End
ft ft Panels in in
T1 190.00-180.00 5.00 K Brace Down No Yes 0.0000 0.0000
T2 180.00-160.00 6.67 K Brace Down No Yes 0.0000 0.0000
T3 160.00-140.00 6.67 K Brace Down No Yes • 0.0000 0.0000
T4 140.00-120.00 6.67 K Brace Down No Yes 0.0000 0.0000
T5 120.00-100.00 10.00 K Brace Down No Yes 0.0000 0.0000
T6 100.00-80.00 10.00 K Brace Down No Yes 0.0000 0.0000
T7 80.00-60.00 10.00 K Brace Down No Yes 0.0000 0.0000
T8 60.00-40.00 10.00 K Brace Down No Yes 0.0000 0.0000
T9 40.00-20.00 10.00 K Brace Down No Yes 0.0000 0.0000
T10 20.00-0.00 20.00 K1 Down No Yes 0.0000 0.0000
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
' Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 13
Tower Secondary Secondary Horizontal Secondary Inner Bracing Inner Bracing Size Inner Bracing
Elevation Horizontal Type Size Horizontal Type Grade
Grade
ft
T2 180.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
160.00 (50 ksi) (36 ksi)
T3 160.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
140.00 (50 ksi) (36 ksi)
T4 140.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
120.00 (50 ksi) (36 ksi)
T5 120.00- Solid Round A572-50 Equal Angle L2x2x1/8 A36
100.00 (50 ksi) (36 ksi)
T6 100.00- Solid Round A572-50 Equal Angle L2 1/2x2 1/2x3/16 A36
80.00 (50 ksi) (36 ksi)
T7 80.00-60.00 Solid Round A572-50 Equal Angle L3x3x3/16 A572-50
(50 ksi) (50 ksi)
T8 60.00-40.00 Solid Round A572-50 Equal Angle L3 1/2x3 1/2x1/4 A572-50
(50 ksi) (50 ksi)
T9 40.00-20.00 Solid Round A572-50 Equal Angle L3 1/2x3 1/2x114 A572-50
(50 ksi) (50 ksi)
T10 20.00-0.00 Solid Round A572-50 Pipe Pipe 2.375"x 0.154"(2 A618-50
(50 ksi) STD) (50 ksi)
Tower Section Geometry (cont'd)
Tower Redundant Redundant Redundant K Factor
Elevation Bracing Type Size
Grade
ISft
T10 20.00- A53-B-35 Horizontal(1) Pipe Pipe 1.9"x 0.145"(1.5 1
0.00 (35 ksi) Diagonal(1) Pipe STD) 1
Hip(1) Pipe Pipe 2.375"x 0.154"(2 1
Hip Diagonal Pipe STD) 1
(1) Pipe 1.9"x0.145"(1.5
STD)
Pipe 2.875"x 0.203"(2.5
STD)
Tower Section Geometry (cont'd)
Tower Gusset Gusset Gusset GradeAdjust. Factor Adjust. Weight Mult. Double Angle Double Angle Double Angle
Elevation Area Thickness A, Factor Stitch Bolt Stitch Bolt Stitch Bolt
(per face) A, Spacing Spacing Spacing
Diagonals Horizontals Redundants
ft ft2 in in in in
T1 190.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
180.00 (36 ksi)
T2 180.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
•
160.00 (36 ksi)
T3 160.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
140.00 (36 ksi)
T4 140.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
120.00 (36 ksi)
T5 120.00- 0.00 0.3750 A36 1 1 1.1. 0.0000 0.0000 36.0000
100.00 (36 ksi)
T6 100.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
80.00 (36 ksi)
17 80.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
60.00 (36 ksi)
T8 60.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
40.00 (36 ksi)
T9 40.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
20.00 (36 ksi)
T10 20.00- 0.00 0.3750 A36 1 1 1.1 0.0000 0.0000 36.0000
0.00 (36 ksi)
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 15
Tower Section Geometry (cont'd)
Tower Leg Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short
Elevation Connection Horizontal
ft Type
Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No. Bolt Size No.
in in in in _ in in in
T1 190.00- Flange 0.8750 4 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
180.00 A325N A325N A325N A325N A325N A325N A325N
T2 180.00- Flange 0.8750 4 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
160.00 A325N A325N A325N A325N A325N A325N A325N
T3 160.00- Flange 1.0000 4 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
140.00 A325N A325N A325N A325N A325N A325N A325N
T4 140.00- Flange 1.0000 6 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
120.00 A325N A325N A325N A325N A325N A325N A325N
T5 120.00- Flange 1.0000 6 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
100.00 A325N A325N A325N A325N A325N A325N A325N
T6 100.00- Flange 1.0000 6 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
80.00 A325N A325N A325N A325N A325N A325N A325N
T7 80.00- Flange 1.0000 8 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
60.00 A325N A325N A325N A325N A325N A325N A325N
T8 60.00- Flange 1.0000 8 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
40.00 A325N A325N A325N A325N A325N A325N A325N
T9 40.00- Flange 1.0000 8 0.6250 3 0.0000 0 0.0000 0 0.6250 0 0.6250 2 0.6250 0
20.00 A325N A325N A325N A325N A325N A325N A325N
T10 20.00- Flange 1.0000 10 0.7500 3 0.0000 0 0.0000 0 0.6250 0 0.7500 2 0.6250 0
0.00 A354-BC A325N A325N A325N A325N A325N A325N
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face Allow Component Placement Face Lateral # # Clear Width or Perimete Weight
or Shield Type Offset Offset Per Spacing Diameter r
Leg ft in (Frac FW) Row in in plf
. in
**Face C**
LDF4- C No Ar(CaAa) 178.00-0.00 0.0000 -0.47 3 2 0.5200 0.6300 0.15
50A(1/2") 0.5000
LDF4- C No Ar(CaAa) 178.00-0.00 0.0000 -0.47 3 3 0.5200 0.6300 0.15
50A(1/2") 0.5000
9207(5/16") C No Ar(CaAa) 178.00-0.00 0.0000 -0.45 3 3 0.3300 0.3300 0.06
2.5"Conduit C No Ar(CaAa) 178.00-0.00 0.0000 0.45 1 1 2.8730 2.8730 5.53
1.5"flat C No Af(CaAa) 178.00-0.00 0.0000 -0.45 2 2 12.0000 1.5000 1.80
Cable Ladder 1.5000
Rail
**Face A**
LDF7-50A(1- A No Ar(CaAa) 130.00-0.00 0.0000 0.4 10 7 0.5200 1.9800 0.82
5/8") 0.5000
ASU9325TY A No Ar(CaAa) 130.00-0.00 0.0000 0.4 3 3 1.5840 1.5840
•
1.61
P01(1-3/5")
1.5"flat A No Af(CaAa) 130.00-0.00 0.0000 0.4 2 2 12.0000 1.5000 1.80
Cable Ladder 1.5000
Rail
**Face B"*
1111 HJ7-50A(1- B No Ar(CaAa) 187.00 0.00 0.0000 0.4 12 12 0.5200 1.9800 1.04
5/8") 0.5000
ATCB- B No Ar(CaAa) 187.00-0.00 0.0000 0.4 3 3 2.1900 0.3150 0.07
B01(5/16) 0.5000
WR- B No Ar(CaAa) 187.00-0.00 0.0000 0.4 5 5 0.7740 0.7740 0.59
VG86ST-
BRD(3/4)
LDF2-50 B No Ar(CaAa) 187.00-0.00 0.0000 0.4 3 3 0.4400 0.4400 0.08
(3/8"foam)
1.5"flat B No Af(CaAa) 187.00-0.00 0.0000 0.4 2 2 12.0000 1.5000 1.80
Cable Ladder 1.5000
Rail
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 17
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustmen Front Side
Leg Lateral
Vert
ft ft ft2 ft2 K
ft •
ft
0.00
WCS-IMFQ-AMT-43 A From Leg 4.00 0.0000 187.00 No Ice 0.55 0.39 0.02
0.00
0.00
WCS-IMFQ-AMT-43 B From Leg 4.00 0.0000 187.00 No Ice 0.55 0.39 0.02
0.00
0.00
RRUS 32 B2 A From Leg 4.00 0.0000 187.00 No Ice 2.73 1.67 0.05
0.00
0.00
RRUS 32 B2 B From Leg 4.00 0.0000 187.00 No Ice 2.73 1.67 0.05
0.00
0.00
RRUS 32 B2 C From Leg 4.00 0.0000 187.00 No Ice 2.73 1.67 0.05
0.00
0.00
(2)DC2-48-60-0-9E A From Leg 4.00 0.0000 187.00 No Ice 0.93 0.56 0.02
0.00
0.00
(2)DC2-48-60-0-9E C From Leg 4.00 0.0000 187.00 No Ice 0.93 0.56 0.02
0.00
0.00
SBJAH4-1 D65B-DL w/ A From Leg 4.00 0.0000 187.00 No Ice 9.47 7.74 0.08
Mount Pipe 0.00
0.00
SBJAH4-1 D65B-DL w/ B From Leg 4.00 0.0000 187.00 No Ice 9.47 7.74 0.08
Mount Pipe 0.00
0.00
SBJAH4-1 D65B-DL w/ C From Leg 4.00 0.0000 187.00 No Ice 9.47 7.74 0.08
Mount Pipe 0.00
0.00
RRUS 32 B66 A From Leg 4.00 0.0000 187.00 No Ice 2.74 1.67 0.05
0.00
0.00
RRUS 32 B66 B From Leg 4.00 0.0000 187.00 No Ice 2.74 1.67 0.05
0.00
0.00
RRUS 32 B66 C From Leg 4.00 0.0000 187.00 No Ice 2.74 1.67 0.05
0.00
0.00
(2)DC2-48-60-0-9E B From Leg 4.00 0.0000 187.00 No Ice 0.93 0.56 0.02
0.00
0.00
DC6-48-60-18-8C B From Leg 4.00 0.0000 187.00 No Ice 2.74 2.74 0.03
0.00
0.00
Sector Mount[SM 502-3] C None 0.0000 187.00 No Ice 33.02 33.02 1.67
LLPX310R-V4 w/Mount A From Leg 4.00 0.0000 178.00 No Ice 4.44 2.85 0.04 •
Pipe 0.00
0.00
Horizon DUO A From Leg 4.00 0.0000 178.00 No Ice 0.47 0.29 0.01
0.00
5.00
nRRHv2 A From Leg 4.00 0.0000 178.00 No Ice 2.49 1.48 0.06
0.00
0.00
JUNCTION BOX A From Leg 4.00 0.0000 178.00 No Ice 0.53 0.27 0.00
0.00
0.00
LLPX310R-V4 w/Mount B From Leg 4.00 0.0000 178.00 No Ice 4.44 2.85 0.04
Pipe 0.00
0.00
Horizon DUO B From Leg 4.00 0.0000 178.00 No Ice 0.47 0.29 0.01
0.00
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 19
Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight
or Type Horz Adjustmen Front Side
Leg Lateral t
Vert
ft ft ft2 ft2 K
ft °
ft
0.00
6'x 2"Mount Pipe C From Leg 4.00 0.0000 130.00 No Ice 1.43 1.43 0.02
0.00
0.00
FASB WI Mount Pipe A From Leg 4.00 0.0000 130.00 No Ice 13.90 14.69 0.24
0.00
0.00
FASB w/Mount Pipe B From Leg 4.00 0.0000 130.00 No Ice 13.90 14.69 0.24
0.00
0.00
FASB w/Mount Pipe C From Leg 4.00 0.0000 130.00 No Ice 13.90 14.69 0.24
0.00
0.00
Sector Mount[SM 104-3] C None 0.0000 130.00 No Ice 30.02 30.02 0.95
Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
ft • ft ft ft2 K
VHLP2-18 A Paraboloid From 4.00 90.0000 178.00 2.17 No Ice 3.72 0.03
w/Shroud(HP) Leg 1.00
5.00
VHLP2-11 B Paraboloid From 4.00 90.0000 178.00 2.17 No Ice 3.72 0.03
w/Shroud(HP) Leg 1.00
6.00
VHLP2-18 C Paraboloid From 4.00 90.0000 178.00 2.17 No Ice 3.72 0.03
w/Shroud(HP) Leg 1.00
5.00
Load Combinations
Comb. Description
No.
1 Dead Only
2 1.2 Dead+1.6 Wind 0 deg-No Ice
3 0.9 Dead+1.6 Wind 0 deg-No Ice
4 1.2 Dead+1.6 Wind 30 deg-No Ice
5 0.9 Dead+1.6 Wind 30 deg-No Ice
6 1.2 Dead+1.6 Wind 60 deg-No Ice
7 0.9 Dead+1.6 Wind 60 deg-No Ice
8 1.2 Dead+1.6 Wind 90 deg-No Ice
•
9 0.9 Dead+1.6 Wind 90 deg-No Ice
10 1.2 Dead+1.6 Wind 120 deg-No Ice
11 0.9 Dead+1.6 Wind 120 deg-No Ice
12 1.2 Dead+1.6 Wind 150 deg-No Ice
13 0.9 Dead+1.6 Wind 150 deg-No Ice
14 1.2 Dead+1.6 Wind 180 deg-No Ice
15 0.9 Dead+1.6 Wind 180 deg-No Ice
16 1.2 Dead+1.6 Wind 210 deg-No Ice
17 0.9 Dead+1.6 Wind 210 deg-No Ice
18 1.2 Dead+1.6 Wind 240 deg-No Ice
19 0.9 Dead+1.6 Wind 240 deg-No Ice
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 21
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. •
T8 60-40 1.154 8 0.1677 0.0177
T9 40-20 0.513 12 0.1079 0.0110
T10 20-0 0.114 20 0.0469 0.0048
Critical Deflections and Radius of Curvature - Design Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ' ° ft
190.00 Flash Beacon Lighting 8 12.127 0.5567 0.1019 974791
187.00 (2)E15S09P78 8 11.769 0.5572 0.1013 974791
184.00 VHLP2-11 8 11.410 0.5571 0.1006 828718
183.00 VHLP2-18 8 11.291 0.5569 0.1004 805454
178.00 LLPX310R-V4 w/Mount Pipe 8 10.694 0.5535 0.0990 152700
130.00 ETW200VS12UB 8 5.573 0.4067 0.0560 16291
Bolt Design Data
Section Elevation Component Bolt Bolt Size Number Maximum Allowable Ratio Allowable Criteria
No. Type Grade Of Load per Load Load Ratio
ft in Bolts Bolt K Allowable
K
T1 190 Leg A325N 0.8750 4 0.27 40.59 0.007 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 1.55 12.43 0.125 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 1.62 12.43 0.130 ✓ 1 Bolt Shear
T2 180 Leg A325N 0.8750 4 6.08 40.59 0.150 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 2.75 12.43
0.221 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 2.23 12.43 0.179 ✓ 1 Bolt Shear
T3 160 Leg A325N 1.0000 4 13.20 53.01 0.249 I/ 1 Bolt Tension
Diagonal A325N 0.6250 3 2.29 12.43
0.184 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 2.13 12.43
0.172 ✓ 1 Bolt Shear
T4 140 Leg A325N 1.0000 6 13.02 53.01 0.246 too' 1 Bolt Tension
Diagonal A325N 0.6250 3 3.24 12.43 0.261 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 3.34 12.43
0.269 ✓ 1 Bolt Shear
T5 120 Leg A325N 1.0000 6 17.40 53.01 0.328 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 3.93 12.43 0.316 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 3.52 12.43
0.283 V 1 Bolt Shear
T6 100 Leg A325N 1.0000 6 22.08 53.01
0.417 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 3.78 12.43 0.304 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 3.68 12.43 0.296 ✓ 1 Bolt Shear
T7 80 Leg A325N 1.0000 8 19.68 53.01 . 0.371 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 3.78 12.43 0.304 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 3.94 12.43 0.317 ✓ 1 Bolt Shear
T8 60 Leg A325N 1.0000 8 22.66 53.01
0.428 r/ 1 Bolt Tension
Diagonal A325N 0.6250 3 4.14 12.43 0.333 ✓ 1 Bolt Shear
Horizontal A325N 0.6250 2 4.57 12.43 0.368 ✓ 1 Bolt Shear
T9 40 Leg A325N 1.0000 8 25.65 53.01 0.484 ✓ 1 Bolt Tension
Diagonal A325N 0.6250 3 4.30 12.43 0.346 ✓ 1 Bolt Shear
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700, Application 358493, Revision 0 Page 23
Section Elevation Size L L. Kl/r A P. 4P„ Ratio
No. P.
ft ft ft in2 K• K OPn
STD) K=1.00 y/
T6 100-80 Pipe 3.5"x 0.216"(3 13.31 12.89 132.9 2.2285 -11.34 28.50 0.398'
STD) K=1.00 /
T7 80-60 Pipe 3.5"x 0.216"(3 14.21 13.82 142.5 2.2285 -11.34 24.78 0.458'
STD) K=1.00 /
T8 60-40 Pipe 3.5"x 0.216"(3 15.12 14.64 151.0 2.2285 -12.42 22.07 0.563 1
STD) K=1.00 I
T9 40-20 Pipe 3.5"x 0.216"(3 16.08 15.62 161.1 2.2285 -12.90 19.40 0.665'
STD) K=1.00 1/
T10 20-0 (37515-2715)2.875"x 24.33 12.17 158.8 3.7615 -19.05 33.70 0.565 1
.276"Pipe w/3.5"x.300" K=1.00 `/
Half Sleeve
1 P„ /OP„controls
Horizontal Design Data (Compression)
Section Elevation Size L L„ Kl/r A P. 4)P„ Ratio
No. P.
ft ft ft int K K +Pn
T1 190-180 Pipe 1.9"x 0.145"(1.5 8.52 4.14 79.8 0.7995 -3.20 22.58 0.142'
STD) K=1.00 /
T2 180-160 Pipe 1.9"x 0.145"(1.5 8.60 4.15 80.0 0.7995 -4.42 22.52 0.196'
STD) K=1.00 V
T3 160-140 Pipe 1.9"x 0.145"(1.5 10.01 4.82 92.9 0.7995 -4.27 19.14 0.223'
STD) K=1.00 (/
T4 140-120 Pipe 2.375"x 0.154"(2 12.10 5.82 88.7 1.0745 -6.68 27.21 0.245'
STD) K=1.00 `/
T5 120-100 Pipe 2.375"x 0.154"(2 13.92 6.68 101.9 1.0745 -7.04 22.64 0.311 '
STD) K=1.00 /
T6 100-80 Pipe 2.375"x 0.154"(2 16.29 7.87 120.0 1.0745 -7.36 16.86 0.436'
STD) K=1.00 1/
T7 80-60 Pipe 2.875"x 0.203"(2.5 18.86 9.15 115.9 1.7040 -7.88 28.64 0.275'
STD) K=1.00 ti/
T8 60-40 Pipe 2.875"x 0.203"(2.5 21.43 10.35 131.1 1.7040 -9.05 22.38 0.404'
STD) K=1.00 (/
T9 40-20 Pipe 2.875"x 0.203"(2.5 23.93 11.60 147.0 1.7040 -9.76 17.82 0.548'
STD) K=1.00 /
T10 20-0 Pipe 2.875"x 0.203"(2.5 25.18 12.23 154.9 1.7040 -10.50 16.05 0.6541
STD) K=1.00 V
P„ /OP„controls •
Top Girt Design Data (Compression)
Section Elevation Size L L. Kl/r A P. OP" Ratio
No. P.
ft ft ft in2 K K 4P"
T1 190-180 Pipe 1.9"x 0.145"(1.5 8.50 4.13 79.6 0.7995 -0.87 22.63 0.038'
STD) K=1.00 I/
1 P /�P„controls
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
' Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 25
Section Elevation Size L L„ KUr A P. 401'„ Ratio
No. P„
ft ft ft in2 K• K 4)P„
T3 160-140 L2x2x1/8 5.01 5.01 151.1 0.4844 -0.01 4.79 0.001 '
K=1.00 V
T4 140-120 L2x2x1/8 6.05 6.05 182.6 0.4844 -0.01 3.28 0.003'
K=1.00 (/
T5 120-100 L2x2x1/8 6.96 6.96 210.0 0.4844 -0.01 2.48 0.003 1
K=1.00 V
T6 100-80 L2 1/2x2 112x3/16 8.15 8.15 197.5 0.9020 -0.01 5.23 0.002 1
K=1.00 V
T7 80-60 L3x3x3/16 9.43 9.43 189.9 1.0900 -0.01 6.83 0.002 1
K=1.00 V
T8 60-40 L3 1/2x3 1/2x1/4 10.71 10.71 185.2 1.6900 -0.01 11.13 0.001 1
11K=1.00 V
T9 40-20 L3 1/2x3 1/2x1/4 11.96 11.96 206.9 1.6900 -0.01 8.92 0.001 '
K=1.00 V
T10 20-0 Pipe 2.375"x 0.154"(2 12.59 12.59 191.9 1.0745 -0.01 6.59 0.002'
STD) K=1.00 V
1 P„ /QP„Controls
Tension Checks
Leg Design Data (Tension)
Section Elevation Size L L„ KUr A P„ +P„ Ratio
No. P„
ft ft ft in2 K K 4)P„
T1 190-180 Pipe 2.875"x 0.276"(2.5 10.00 5.00 64.9 2.2535 0.33 101.41 0.003'
XS) i✓
T2 180-160 Pipe 3.5"x 0.300"(3 XS) 20.00 6.67 70.4 3.0159 24.31 135.72 0.179'
V
T3 160-140 Pipe 4.5"x 0.337"(4 XS) 20.04 6.68 54.3 4.4074 52.79 198.34 0.266'
V
T4 140-120 Pipe 5.563"x 0.375"(5 20.04 6.68 43.6 6.1120 78.11 275.04 0.284 1
XS) V
T5 120-100 Pipe 6.625"x 0.340"(6 20.04 10.02 54.0 6.7133 104.43 302.10 0.346'
EHS)
T6 100-80 Pipe 6.625"x 0.432"(6 20.05 10.03 54.8 8.4049 132.48 378.22 0.350'
XS) V
T7 80-60 Pipe 6.625"x 0.432"(6 20.06 10.03 54.8 8.4049 157.46 378.22 0.416'
XS) V
T8 60-40 Pipe 8.625"x 0.375"(8 20.05 10.03 41.2 9.7193 181.31 437.37 0.415 1
EHS)
T9 40-20 Pipe 8.625"x 0.375"(8 20.05 10.03 41.2 9.7193 205.17 437.37 0.469 1
EHS)
T10 20-0 Pipe 8.625"x 0.500"(8 20.05 10.03 41.8 12.762 214.87 574.32 0.374 1
XS) 7 - V
1 P„ I.Pn controls
Diagonal Design Data (Tension)
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
- Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 27
Section Elevation Size L L. Kik A P. 4)P„ Ratio
No. P„
ft ft ft in2 K• K gyp„
T1 190-180 Pipe 1.9"x 0.145"(1.5 8.50 4.13 79.6 0.7995 0.87 35.98 0.024'
STD)
1 P u /4P„controls
Redundant Horizontal (1) Design Data (Tension)
Section Elevation Size L L. Kik A P. OP„ Ratio
No. P.
ft ft ft in2 K K 4)P„
T10 20-0 Pipe 1.9"x 0.145"(1.5 6.29 5.93 114.4 0.7995 4.29 25.18 0.171 '
STD) /
• 1 P„ /4P„controls
Redundant Diagonal (1) Design Data (Tension)
Section Elevation Size L L„ KUr A P. (I)P„ Ratio
No. P„
ft ft ft in2 K K 4iP„
T10 20-0 Pipe 2.375"x 0.154"(2 11.50 10.77 164.2 1.0745 3.92 33.85 0.116 1
STD) I,
1
P„ /OP„controls
Redundant Hip Diagonal (1) Design Data (Tension)
Section Elevation Size L L. Kik A P. 41P0 Ratio
No. P„
ft ft ft in2 K K 4)P„
T10 20-0 Pipe 2.875"x 0.203"(2.5 15.07 15.07 190.9 1.7040 0.08 53.68 0.001 1
STD) /
1
P„ /OP„controls
Inner Bracing Design Data (Tension)
Section Elevation Size L L. Kl/r A P. 4P„ Ratio
No. P"
ft ft ft in2 K K c6P„
T1 190-180 L2x2x1/8 4.25 4.25 81.4 0.4844 0.02 15.69 0.001 1
i✓
T2 180-160 L2x2x1/8 4.30 4.30 82.4 0.4844 0.01 15.69 0.000
T3 160-140 L2x2x1/8 4.31 4.31 82.6 0.4844 0.00 15.69 0.000'
I✓
T4 140-120 L2x2x1/8 6.05 6.05 115.9 0.4844 0.00 15.69 0.0001
VI
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 29
Section Elevation Component Size Critical P OPa,b,v % Pass
No. ft Type Element K K Capacity Fail
T3 160-140 Inner Bracing L2x2x1/8 81 -0.01 '4.79 0.1 Pass
T4 140-120 Inner Bracing L2x2x1/8 119 -0.01 3.28 0.3 Pass
T5 120-100 Inner Bracing L2x2x1/8 158 -0.01 2.48 0.3 Pass
T6 100-80 Inner Bracing L2 1/2x2 1/2x3/16 186 -0.01 5.23 0.2 Pass
T7 80-60 Inner Bracing L3x3x3/16 212 -0.01 6.83 0.2 Pass
T8 60-40 Inner Bracing L3 1/2x3 1/2x1/4 240 -0.01 11.13 0.2 Pass
T9 40-20 Inner Bracing L3 1/2x3 1/2x1/4 267 -0.01 8.92 0.2 Pass
T10 20-0 Inner Bracing Pipe 2.375"x 0.154"(2 STD) 310 -0.01 6.59 0.2 Pass
Summary
Leg(T9) 60.4 Pass
'1 Diagonal 73.8 Pass
(T4)
Horizontal 65.4 Pass
(T10)
Top Girt 3.8 Pass
(T1)
Redund 33.3 Pass
Horz 1
Bracing
(T10)
Redund 43.6 Pass
Diag 1
Bracing
(T10)
II Redund 0.4 Pass
Hip 1
Bracing
(T10)
Redund 0.5 Pass
Hip
Diagonal 1
Bracing
(T10)
Inner 0.3 Pass
Bracing
(T5)
Bolt 48.4 Pass
Checks
RATING= 73.8 Pass
0
tnxTower Report-version 7.0.5.1
August 17, 2016
190 Ft Self Support Tower Structural Analysis CCI BU No 812565
Project Number 37516-1744.002.8700,Application 358493, Revision 0 Page 31
APPENDIX C
ADDITIONAL CALCULATIONS
4
tnxTower Report-version 7.0.5.1
190.0 ft
I_aemesa
W _ m o 1111 .111111111111111
_•
N 180.0 ft SYMBOL LIST
N ^ = I1,III1I1111111 MARK SIZE MARK SIZE
.... A Pipe 2.875"x 0.276"(2.5 XS) F Pipe 2.375"x 0.218'(2 XS)
m
N - B Pipe 5.563"x 0.375"(5 XS) G Pipe 2.875"x 0203'(2.5 STD)
F d a
�'+ m 2 C Pipe 6.625"x 0.340'(6 EHS) H (37515-2715)2.875'x.276"Pipe w!3.5'x.300"..__. _... D Pipe 8.625'x 0.500"(8 XS) Half Sleeve
'" + E Pips 2.375'x 0.154"(2 STD) I Pipe 1.9'x 0.145'(1.5 STD)
E. o
, - 190.ort MATERIAL STRENGTH
(7, m GRADE Fy Fu GRADE Fy Fu
S o_ r A618-50 50 ksi 70 ksi A500-46 46 ksi 62 ksi
ft k O § ., W_,•1•
y e 0 - TOWER DESIGN NOTES
O1. Tower is located in Duval County,Florida.
8 i I 2. Tower designed for Exposure C to the TIA-222-G Standard.
.._�._.
ii 140.0 ft
O - 3. Tower designed for a 100 mph basic wind in accordance with the TIA-222-G Standard.
x m
4. Deflections are based upon a 60 mph wind.
o 5. Tower Structure Class II.
N L 6. Topographic Category 1 with Crest Height of 0.00 ft
m it. tim 2 G®I 111 1111 7. TOWER RATING:73.8%
120.0 ft
- O �-
1- 70" `: \
CO /% '\
C V 0 c 2 ..._____
x
b N
m ,r, aaa
m N z z z
8 100.0 ft
o $ Qm N
a
c_
I
D80.0ft •..
O'
a '
h' ,,
o o o
N
M
Io
BO.Oft /
.._____._...'
_ N _
r ,
_
N
d pN
'a 6'
-
m
' ALL REACTIONS
•
$ - 40.0ft %__ ` ARE FACTORED
-X % xn / \
L'" /
m „ r / MAX.CORNER REACTIONS AT BASE:
°° J N i DOWN: 273 K
• M & a /N SHEAR: 34 K
/ UPLIFT: -238 K
20.0 ft N. SHEAR: 31 K
• AXIAL
N 59 K
!en S Qg _ W _ W 0 D ...
d •
SHEA MOMENT
58 K I 6139 kip-ft
o.on
TORQUE 29 kip-ft
"' REACTIONS-100 mph WIND
N
• og-
v ° •3 •••me•, m 9o m n m$m sg ?v
•
o e ` o (7 d E.
l o o $° n'c c 6 v c a a
• Paul J Ford and Company MoD 190-ft Self Support Tower Atlantic Beach,FL
250 E. Broad Street Suite 600 I'°1 PJF#37516-1744 BU#812565)
Columbus, OH Client Crown Castle Drawn by'Matthew R Buske Pppd.
Phone:43215 cede' TIA-222-G Dale:08/17/16 scale: NTS
FAX:614.448.4105 Pam: v.cNae- ,01,14,,...,x,.,...., .o..».no..,...1n..a.Wt.,,..Or170>..DwgNo.E-1