Loading...
1089 ATLANTIC BLVD - FIRE ALARM DRAWINGS LL HVAC HVAC HVAC HVAC H H r(@ FOS UP 10x10 C10xi0 010x10 C10xi0 Cloxi0 C10xi0 C10x10 010x10 010x10 010x10 C10xi0 010x10 010x10 010x10 010x10 C10xi0 C10x10 010x10 010x10 G10x10 0 W N c):f n 111 CN C1040c10x2QJ 1 (� F C F C 0 o 0 -1 � � N 05x5 G5x10 05x10 W Q 05x10 05x10 05x10 3: z 05x5 010x10 010x10 Clox10 cloxi0 C10xi0 C10xi0 C10xi0 C10xi0 010x10 010x10 C10xi0 0 C10xi0 C10x20 C10x20 010x20 C10x20 C10x20 010x10 O i`� U Q C5xi0 05x10 Cloxi5 C10x15 C10x15 05x10 cis -7 010x10 010x10 010x10 010x10 010x10 C10xi0 010x10 010x10 C10xi0 010x10 010x10 11 ClOx10 il 11 11 1 1 11 010x10 Ec UNITS 05x5 05x5 c5 x10 05x10 05x10 05x10 c5x10 G5x10 05x10 c5x10 05x10 05x10 05x10 05x10 C5xi0 05x10 05x10 05x10 05x10 c5x10 woo ._ 10x10 0C}0xi0 x.. 05x5 05x5 Q� D E.EV 13 KEYPAD EQUIP w 05x5 u- 05x10 C10x15 C10x15 LOADING 010x10 010x10 2 VI (D 4 12 05x10 HVAC C10x30 GiOx30 C10x30 C10x30 C10x30 C10x30 C10x30 CiOx30 C10x30 C10x30 C10x30 CIOx30 C10x30 C10x30 C10x30 E C 05x5 HYAc 05x10 010x10 010x10 HVAC { 010x15 05x10 010x15 FEC 05x10 05x10 HYAC 05x10 (D CLOS R•S O O uu� O O 05x5 co KiTCHEN N f3DR1"i FLOOR 010x12 cz DRAIN 5 S FEC EC � 70 N WH > M 5ATH rtECH 0 G5x5 7G5x5 05x5 �� Y 05x5 0.5x10 c CLOS .i . I OI a H -- _ 0 4 T 2 3 010x15 i LTA -�- ` I OFF-I C 101 w D IN INCA 05x10 ELEV 05x10 C10x20 EQUIP EL 05x10 C -- ih1EC.FIi i 0 0.5x10102 i Q� Cz U ® LG.G FE C10x30 C10x30 C10x30 C10x30 C10x30 C10x30 C10x30 Ci0x30 C10x30 C10x30 10x30 F c _ 4-a+ 0 F C i @� < M. 5ATI••-4 0 e14 x15 10G C5 COUNTER 10 SPfi�'I K T F c M. i„i a T i�' 2 - LOAD(NG 105 E3D R LIVING LEC TLT c� C5xi0 010x10 75 t I--------- ❑ c 4� UP KEYPA FSC �____. SAL. --- cz GP cz rr 15 10B 107 FOS iV tOX 101 1I I FOC I i I�O^ I I 1 I I 1 i BUILDING INFORMATION �_______ ' ---------- 0 0 0 1 I I ROOF I GENERAL DESCRIP'TIOR FIRE ALARM A-0 CRITERIA:_ i EXTERIOR SPRINKLED BUILDING ------- O° O° I OCCUPANCY TYPE: - - r- -------------�-; MOUNTED i I (A) THE PLANS SHALL BE CLEAR, WITH A SYMBOLS LEGEND, SYSTEM RISER DIAGRAM SHOWING ALL INITIATION AND NOTIFICATION COMPONENTS, AND CABLING REQUIREMENTS. INDICA LOCATIONS L_______________________________________.___-_- � / I "I ABOVE FSC DS HVAC f WHERE FIRE RATINGS ARE REQUIRED AS DETERMINED BY THE 3 STORY STORAGE Cx, x, xS 1 (SEE NOTE 10) I SYSTEM'S SURVIVABILITY REQUIREMENTS. IDENTIFY THE GENERAL OCCUPANCY OF THE PROTECTED PROPERTY, AND FOR EACH ROOM AND AREA UNLESS IT IS CLEAR FROM FEATURES SHOWN. FULLY SPRINKLERED •• H 5 ..—...—...—. 7 WIP L-----------i — OCCUPANCY TYPE3 STORY STORAGE DOES STRUCTURE HAVE AUTOMATIC SPRINKLER SYSTEM? B T F "'—"'—"' j I i (B) LOCATE INITIATION AND NOTIFICATION DEVICES AND CONNECTIONS TO RELATED SYSTEMS ON THE FLOOR PLANS AND SECTIONS WHEN NEEDED FOR CLARITY. RELATED SYSTEMS INCLUDE El NO ElFI PARTIAL ®FULL RE SPRINKLER CONTROLLER LEGEND ELEVATOR CONTROLS SMOKE CONTROL SYSTEMS, DAMPERS, AND DOORS. ' FIRST FLOOR FIRE ALARM PLAN SPD — ELEVATOR RECALL PROVIDED AS REQUIRED. SCALE: 1/8" = 1'-0" 8 I I FIRE SPRINKLER © PULL STATION WALL MTD APPLICABLE CODE SUMMARY: j CONTROLLER (C) STROBE INTENSITY AND SPEAKER OUTPUT RATINGS FOR ALL NOTIFICATION DEVICES. '"LOOR PLAN NOTES: 2010 FLORIDA BUILDING CODE 75 H�J, HORN/STROBE WALL MTD • j 1 REVISIONS 5TH EDITION FLORIDA FIRE PREVENTION CODE — ONLY ONE NOTIFICATION DEVICE IS REQUIRED PER NFPA 72 FOR CENTRAL STATION COMMUNICATOR 1. LOCATE SMOKE DETECTOR ON CEILING OF ELEVATOR LOBBY — 2011 NFPA 101 — LIFE SAFETY CODE ANNUNCIATOR MOUNTED B BELL WALL MTD DATE REV TYPICAL FOR ALL THREE FLOORS. �3Lp " BESIDE FSC -- 2010 NFPA 72 — NATIONAL FIRE ALARM AND �® •••—••..... ... S SMOKE DETECTOR CLG MTD 2. PROVIDE SMOKE/HEAT DETECTOR AT TOP OF ELEVATOR SHAFT. SIGNALING CODE. PNL 0— ® _ P 0 (D) IDENTIFY THE CLASS AND STYLE OF CIRCUITS AS LISTED IN THE NFPA 72. 3. PROVIDE SMOKE/HEAT DETECTOR iN ELEVATOR PIT. 2011 NFPA 70 — NATIONAL ELECTRIC CODE DEDICATED 120V CKT FSC T F TAMPER/FLOW SWITCHES - 4. INTERLOCK FIRE ALARM DETECTION DEVICES WITH ELEVATOR SPD NOTE 12 — SYSTEM ALL BE CLASS B STYLE Y. CONTROLLER AS REQUIRED FOR ELEVATOR RECALL UPON FIRE ALARM DS DUCT SMOKE DETECTOR SYSTEM ACTIVATION. I (BY MECH CONTRACTOR) (E) IDENTIFY THE FUNCTIONS REQUIRED BY THE ALARM AND CONTROL SYSTEMS INCLUDING THE TRANSMISSION OF EMERGENCY SIGNALS BEING MONITORED OR ANNUNCIATED. j SEAL . ...—...—...—...•—...-.� (2) TELE LINES — FIRE ALARM SYSTEM CONTROL IS PROVIDED. •••—•••—•••—••• TO SECURITY PNL (F) INDICATE WHETHER THE FIRE ALARM IS CONVENTIONAL OR ADDRESSABLE, AND INDICATE ALL ZONING. FLOOR — SYSTEM IS AN ADDRESSABLE SYSTEM. NOTIFICATION APPLIANCE DEVICE ADDRESS SHOWN FOR EACH DEVICE IN PLAN AND RISER ViEW. (G) LOCATE SURGE PROTECTIVE DEVICES AND REQUIRED PROTECTIVE FEATURES. CENTRAL STATION COMMUNICATOR - SURGE PROTECTION PROVIDED AT FRCP. SPRINKLED BLDG (H) LOCATE SYSTEM DEVICES THAT ARE SUBJECT TO ENVIRONMENTAL FACTORS, AND INDICATE REQUIREMENTS FOR THE PROTEc-nON OF EQUIPMENT FROM TEMPERATURE, HUMIDITY OR CORROSIVE NO SCALE ATMOSPHERES, INCLUDING COASTAL SALT AIR. RISER NOTES: — DEVICES INDICATED AS WP SHALL BE WEATHERPROOF AS 1. RiSER IS DiAGRAMMATICAL ONLY. MONITORED DEVICES SHOWN ON DRAWINGS ARE A REQUIRED FOR ENVIRONMENTAL FACTORS. ALL OTHER DEVICES ARE NEMA—'I THOMAS ELDER, P.E. MINIMUM QUANTITIES QANDEMENT. FIRE LOCATIONS OF ALL 1DEVIu�'',i MAKE NG RA PROMSION FOR DICTATE ADDIT ADDITIONAL FINAL1409 KINGSLEY AVE BLDG 12A DEVICES. '. ORANGE PARK FL, 32073 (I) THE PLANS SHALL iNCLUDE A S1TE PLAN OF THE IMMEDIATE AREA AROUND THE PRO'1"ECTED BUILDlNG, �7F�i�CT�lRE (�-EQUIPMENT WHEN ALAR ,V �► A Q�JJRED 011TSIDE HE � STRUCTURE. 2. FIRE SPRINKLER CONTROLLER (FSC) SHALL 1E INSTALLED IN AIR CONDITIONED SPACE I FL PE: 66121 -EXTERIOR NOTIFICATION PROVIDED BY BELL TRIGGERED BY SPRINKLER FLOW SWITCH � ONLY. iT SHALL BE MONITORED WITH AUTOOIALER. DIALER REQUIRES 2 TELEPHONE (904) 403-9067 LINES AHEAD OF PBX WITH RJ KS. (J) IN BUILDINGS WERE SMOKE DETECTION WILL BE OBSTRUCTED BY WALLS, BEAMS OR CEILING FEATURES, THE ENGINEER OF RECORD SHALL PROVIDE APPLICABLE DESIGN AND DETAIL TO 3. FIRST ZONE SHAT. 1) SMOKE DETECTOR INSTALLED ABOVE FSC & (i) PULL DIRECT THE INSTALLER TO MITIGATE THE OBSTRUCTIONS. IN BUILDINGS WITH SMOKE DETECTION UNDER A PITCHED ROOF, THE PLANS SHALL INDICATE THE ROOF PITCH AND A BUILDING SECTION STA11 D BESIDE CSC. SHALL BE PROVIDED AS PART OF THE ENGINEERING DESIGN DOCUMENTS. 4. SECOND ZONE SHALL BE FOR SPRINKLER FLOW SWITCH. @ n,mm IL aEklkw, PY_ 5. THIRD ZONE SHALL BE FOR SPRINKLER TAMPER SWITCH. DATE 07/13/!5 -- THIS CONDITION DOES NOT EXIST. SMOKE DETECTORS ARE CEILING MOUNTED AND DETECTION IS NOT OBSTRUCTED BY BUILDING MEMBERS. 6. FOURTH ZONE SHALL SMOKE DETECTORS 7. FIFTH ZONE SHALL BE HEAT DETECTOR(S). (K) FIRE DETECTION SYSTEMS UTILIZING SMOKE DETECTION NSITUATIONS WHERE SMOKE STRATIFICATION IS ANTICIPATED, THE DESIGN SHALL PROVIDE THE NECESSARY CRITERIA TO MITIGATE THE 8. COORDINATE LOCATION & QUANTITY OF TAMPER/FLOW SWITCHES WITH SPRINKLER FIRE PROJECT N0. DETECTION PROBLEMS. PROTEC2015-051 S TION DRAWINGS. 9. ALARM BELL SHALL BE LOCATED ON STREET SIDE OF BLDG & MOUNTED 8FT AFG. REVIEWED FOR CODE COMPLIANCE — NOT APPLICABLE. 10. ELEVATOR RECALL SHALL BE PROVIDED BY ELEVATOR CONTOLLER, NOT PART OF CITY OF ATLANTIC BEACH MONO'RRING. (L) SYSTEMS DESIGNED USING PERFORMANCE BASED CRITERIA SHALL BE IDENTIFIED AND REFERENCED TO DESIGN GUIDES OR STANDARDS APPROVED BY THE LOCAL AUTHORITY HAVING 11. SURGE PROTECTIVE DEVICE -- DITEK #DTK120HW SEE PERMITS FOR ADDITIONAL JURISDICTION CONSISTENT WITH STANDARDS ADOPTED BY THE FLORIDA FIRE REQUIREMENTS AND CONDITIONS PREVENTION CODE AND THE FLORIDA BUILDING CODE (2007). REVIEWED BY: DATE: f-%(% — CODE SUMMARY IS PROVIDED (THIS SHEET). (M) THE SYSTEM DESIGN MUST INDICATE iF THE SYSTEM IS TO PROVIDE A GENERAL EVACUATION SIGNAL OR A ZONED EVACUATION FOR ALL HIGH—RISE BUILDINGS OR MULTI—TENANTED PROPERTIES AS DEFINED IN THE FLORIDA BUILDING CODE (2007). A - SYSTEM WILL PROVIDE NOTIFICATION UPON FLOW SWITCH ACTIVATION FIRE ALARM FLOOR (N) WIRING REQUIREMENTS FOR UNDERGROUND, WET LOCATIONS, CAMPUS STYLE WIRING, PROTECTION AGAINST DAMAGE AND BURIAL DEPTH SHALL BE SPECIFIED OR INDICATED ON THE PLAN AND RISER ENGINEERING DESIGN DOCUMENTS. REVIEWED — ALL WIRING IS ABOVE GRADE OR INTERIOR AND NOT SUBJECT TO DAMAGE. fhWk"n rflf*pfft Preventfon dhr D ETAI L (0) REQUIREMENTS FOR OPERATIONS AND MAINTENANCE PROCEDURES, MANUALS, SYSTEM DOCUMENTATION, AND INSTRUCTION OF OWNER'S OPERATING PERSONNEL, AS NEEDED TO OPERATE THE NOV O 7 2016 Ofi SHEET NAME: SYSTEMS AS INTENDED OVER TIME. D IQ% NO�J(C!M'f4N8 - OPERATIONS AND MAINTENANCE MANUAL IS REQUIRED BY SPECIFICATIONS 13 00"IONS AS NO= 0 SHM CaA FA- 1 FIRE ALARM FLOOR PLAN AND RISER DETAIL SCALE 2 1/811=1-011