Loading...
850 SEMINOLE RD - FIRE SPRINKLER PERMIT .�r\J f. ✓r 7 �`' 'i ` CITY OF ATLANTIC BEACH 2 800 SEMINOLE ROAD - -` ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL FIRE SPRINKLER MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-MCHF-2715 Job Type: MECHANICAL FIRE PERMIT Description: install 3 fire sprinkler systems Estimated Value: $97,000.00 Issue Date: 12/6/2016 Expiration Date: 6/4/2017 PROPERTY ADDRESS: Address: 850 SEMINOLE RD RE Number: None GENERAL CONTRACTOR INFORMATION: Name: W.W. GAY FIRE PROTECTION , 344022-0001-2003 I Address: 522 STOCKTON ST QA ANDRZEJ RATAJCZYK Phone: - - FEES: Trade Permit Base Fee $35.00 Total Payments: $35.00 I ilPERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax(904) 247-5845 I b_ AA G 14P- SJOBa--i- IS— JOB ADDRESS: 850 Seminole Rd.Atlantic Beach, FL PERMIT# PROJECT VALUE$ 97,000.00 ARI# REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only — NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity 3 systems (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name City of Atlantic Beach Phone Number 904-387-7973 904-394-7261 Mechanical Company WW Gay Fire & Integrated Systems, Inc. Office Phone Fax CO. Address: 522 Stockton St. City Jacksonville StateFL zip 32204 License Holder (Print): Donna Molinaro �iaie Certification/Registration # 344022-0001-2003 Notarized Signature of License Holder N. r^ = —="°"�efore me this 28 day of November 20 16 �s*es'6s. `%f ANDA L CARTER I ,,/ ' 'MISSION*FF7E535 i i nature of Notary Public `_1�(�A,C1- LM y; .: 'tecember 14,2017 � g >�� �• `�..y •, aryPubicUndc er5�• Printing :: CR393101 Page 1 of 1 Duval County, City Of Jacksonville Michael Corrigan ,Tax Collector 231 E.Forsyth Street Jacksonville,FL 32202 General Collection Receipt Account No:CR39310I Date: 12/6/2016 User:Padgett,Hardy Email:HPadgett@coj.net FIRE MARSHALL FEE FOR SERVICES PROVIDED Name: W.W.Gay Fire Protection Address:522 Stockton Street,Jacksonville,Florida 32204 Description:Public Safety Building,850 Seminole Road,Atlantic Beach,Florida 32204 Fire Sprinkler Installation Pressure Test and Final Acceptance Test Required TranCode I IndexCode I SubObject I GLAcct I SubsidNo I UserCode I Project I ProjectDtl I Grant I GrantDtl I DocNo I Amount 701 I FRFP159F1 I 34222 I ( I I I I I I I 175.00 Total Due:$175.00 Michael Corrigan ,Tax Collector General Collections Receipt City of Jacksonville, Duval County Account No:CR393101 FIRE MARSHALL FEE FOR SERVICES PROVIDED Date: 12/6/2016 Name:W.W.Gay Fire Protection Address:522 Stockton Street,Jacksonville,Florida 32204 Description:Public Safety Building,850 Seminole Road,Atlantic Beach,Florida 32204 Fire Sprinkler Installation Pressure Test and Final Acceptance Test Required • Total Due:$175.00 nn: r.nt/Tr r17/r.rir.tir.n nor.v7nr-01?1011 A 1 17/612016 GAY W.W. GAY FIRE & INTEGRATED SYSTEMS, INC. 522 STOCKTON STREET•JACKSONVILLE,FL 32204•PHONE 904-387-7973• www.wwGFP.COM FIRE PROTECTION MATERIAL SUBMITTALS FOR: ATLANTIC BEACHPUBLIC SAFETY BLDG. 850 SEMINOLE RD. ATLANTIC BEACH, FL Date: November 18, 2016 Our Project Number: FP-208716 Project Manager: D. Molinaro The materials submitted represent the quality of material- ; - ' - t, materials may be substituted at this contractor's dirii 1_9 r. _vention Div equivalent materials. DEC 0 6 2016 ❑NO EXCEPTIONS CI EXCEPTIONS AS NOTED W. W. Gay Fire & Integrated Systems, IMET# 522 Stockton Street/ 2500 N.E. 18th Terrace Jacksonville, Florida 32204 / Gainesville, Florida 32609 (904) 387-7973 / (352) 380-0317 Fire Protection Steel Piping Schedule 10/Schedule 40 Specifications/Approvals: ASTM A-135 NFPA 13 UL Listed FM Approved 300 psi working pressure Sizes: Schedule 40: 1" - 2" (Threaded & Grooved) Schedule 10: 2 '/2" - 8" (Roll Grooved) Manufactured by: Wheatland Tube Company Bull Moose Tube Company or equivalent Submittal Prepared by: W. W. Gay Fire & Integrated Systems, Inc. 522 Stockton Street/2500 N.E. 18th Terrace Jacksonville, Florida 32204 / Gainesville, Florida 32609 (904) 387-7973 / (352) 380-0317 STRAIGHT TEE AM/' Star- � Fire Products Division of Anvil`International c SPF/RNVIL' Ductile Iron Submittal Sheet ill STRAIGHT TEE Nominal Anvil Item Universal Max.Working Dimensions Approx. Size Number Number Pressure Wt.pEach f ill A B B 1 840003164 D1333 500 1.50 1.50 0.85 L. 25 3450 38.10 38.10 0.39 11/4 840003172 DT444 500 1.15 1.75 1.22 I 32 3450 44.45 44.45 0.55 N—A—.-:,-.—A—►I 11/ 840003180 D1555 500 1.94 1.94 1.55 40 3450 49.27 49.27 0.10 2 840003198 01666 500 2.25 2.25 2.45 50 3450 51.15 57.15 1.11 MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL & ULC Listed & Dimensions conform to ASME 816.3 Class 150. ® I Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME 81.20.1 . 11> Ductile iron per ASTM A536 Class 65-45-12. APPROVED For Listing/Approval NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore,over tightening con cause damage to pipe threads which may cause leakage.Ductile details contact your iron fittings should be tightened three turns beyond hand tight,but no more than four turns. AnvilStarTM Representative. PROJECT INFORMATION: APPROVAL STAMP: Project: Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast&Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule, 7 - REV.03.03.06-0013 go to www.anvilstar.com or contact your local AnvilStar representative ' Zi4MnL TM Listings and Approvals GENERAL CODES, STANDARDS, SPECIFICATIONS, ASSOCIATIONS & APPROVAL BODIES VGS production facilities are certified to ISO 9001. Products are designed to conform to ASTM and other standards where applicable and are listed, approved and or certified by cULus, ULC, FM, NSF and others. VGS is active in industry membership organizations such as AFSA, NFSA, CASA, NFPA,IFSA,and others. AFSA CE C E NFPA inii American Fire Sprinkler Association National Fire Protection Association NFPA 13 NFPA ANSI ANSI FM ® NSF U American National Standards Institute Factory Mutual Research Corp.- APPROVED ANSI/NSF 61 Drinking Water System ."`"0V1f Approved for fire protection services Component-Health Effects ASTM American Society of Testing and Materials IFSA (0" UL COOS F 1476-01 Couplings International Fire Sprinkler Association Underwriter's Laboratories,Inc.-UL213 LISTED F 1548-01 Fittings6 .c FIRE M E MBE 2 NFSA SPRINKLER ULC AssocASSOCIATION.CASA c National Fire Sprinkler Association,Inc. ® Underwriter's Laboratories of Canada Canadian Automatic Sprinkler Association "0" I I I I Grooved Piping Systems Hole-Cut Piping System V-7706 Reducing Coupling cULus/FM V-M21 Mechanical Tee,Threaded Outlet cULus/FM V-7041 Flange Adapter-ANSI 125/150,PN10/16 cULus/FM V-M22 Mechanical Tee Grooved Outlet cULus/FM V-7110 90°Elbow,Regular Radius cULus/FM V-7110DR Drain Elbow cULus/FM Fire Protection Systems V-7705 Standard Flexible Cou.lin. cULus/FM V-7111 45°Elbow,Regular Radius cULus/FM V-7112 22-1/2°Elbow cULus/FM V-Z05 Ri.id Cou.lin. cULus/FM V-7113 11-1/4°Elbow cULus/FM V-899 End-All Fittin. cULus/FM V-7120 Tee cULus/FM V-901 Short Radius 90°Elbow cULus/FM V-7121 Reducing Tee cULus/FM V-903 Short Radius Tee cULus/FM V-7135 Cross cULus/FM V-723 Saddle-Let cULus/FM V-7150 Conc.Reducer cULus/FM V-M21 Mechanical Tee,Threaded Outlet cULus/FM V-M22 Mechanical Tee,Grooved Outlet cULus/FM V-7160 Domed End Cap cULus/FM Trusted above all.' a VIKING 1 of 2 NGso GROOVED COUPLING TECHNICAL DATA MODEL V-7705 STANDARD FLEXIBLE COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION VGSE Model V-7705 Standard Flexible Couplings are avaialble in sizes 1"through 12". Fitting solutions are available in a number of styles and configurations to support a variety of applications. VGSc"Standard Flexible Couplings are manufac- tured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. 2. LISTINGS AND APPROVALS .1111 cOus Guide No. VIZM ® Class 1920 -etB IC 3. TECHNICAL DATA The latest VGSZ Technical Data can be acessed at Specifications: http://www.vikinggroupinc.com. Maximum working pressure: 300 psi (21 bar) Scan to visit our Mobile website: Ductile iron conforming to ASTM A536 Grade 65-45-12 J ' 1-JJ Coating rust inhibiting paint-Orange RAL 20014 Hot dipped Zinc galvanized versions are availa- ',":7e41. "�;F.il •r� ble(conforming to ASTM A153);when order- I z r �'-..._. ing, add a"G"suffix to the Model number. rim NI r. a Rubber compound EPDM Grade E conforming + Model V-7705 to ASTM D2000,AWA C606, NSF 61 and http://vikinggroup.mobi/p/46374 Standard Flexible Coupling W IAPMO. Nuts:Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10621 Boron Steel Table 1: V-7705 1 1.315 300 406 0.0625 2.2 3.94 1.77 2 3/8 x 1-3/4 1.3 (25) (33) (21) (1.75) (1.6) (56) (100) (45) (M10 x 45) (0.6) 1.25 1.66 300 649 0.0625 2.58 4.09 1.85 2 3/8 x 2-1/8 1.4 (32) (42) (21) (2.79) (1.6) (66) (104) (47) (M10 x 55) (0.6) 1.5 1.9 300 850 0.125 2.82 4.25 1.815 2 3/8 x 2-1/8 1.6 (40) (48) (21) (3.66) (3.2) (72) (108) (47) (M10 x 55) (0.7) 2 2.375 300 1330 0.125 3.39 5.12 1.89 3/8 x 2-1/8 1.9 (50) (60) (21) (5.71) (3.2) (86) (130) (48) 2 (M10 x 55) (0.9) 2.5 2.875 300 1950 0.0625 3.82 5.63 1.89 3/8 x 2-1/8 2.0 (65) (73) (21) (8.37) (1.6) (97) (143) (48) 2 (M10 x 55) (1.9) 3 3.5 300 2885 0.125 4.49 6.42 1.93 2 1/2 x 3 3.1 (80) (89) (21) (12.41) (3.2) (114) (163) (49) (M12 x 75) (1.4) 4 4.5 300 4771 0.125 5.83 7.80 2.05 2 1/2 x 3 4.6 (100) (114) (21) (24.77) (3.2) (148) (198) (52) (M12 x 75) (2) 5 5.563 300 7290 0.125 6.79 9.25 2.09 2 5/8 x 3-1/2 6.3 (125) (141) (21) (32.45) (3.2) (173) (235) (53) (M16 x 90) (2.9) 6 6.625 300 10340 0.125 7.91 10.55 2.13 2 5/8 x 3-1/2 7.3 (150) (168) (21) (46.02) (3.2) (201) (268) (54) (M16 x 90) (3.3) 8 8.625 300 17525 0.25 10.35 13.27 2.44 5/8 x 3-1/2 12.1 (200) (219) (21) (78) (6.4) (263) (337) (62) 2 (M16 x 90) (5.5) 10 10.75 300 27228 0.125 12.76 15.51 2.62 3/4 x 4-3/4 19.7 (250) (243) (21) (121.19) (3.2) (324) (394) (67) 2 (M20 x 120) (8.9) 12 12.75 300 38302 0.189 14.65 17.72 2.62 2 7/8 x 6-1/2 25.1 (300) (330) (21) (170.47) (4.8) (372) (450) (67) (M22 x 65) (10.9) Form No. F_021214 16.03.04 Rev 16.1 Replaces form No. F_021214 Rev 15.1 (Reformatting and corrections) P 7 x t BROCHUREzti' f ....,,,,, . „ } { K } „,,,. .. ,2 , :: . . c .:. - „;,,.„:„.„-:,.„ . .,,,,,,„:„,,..,.....„:„,.„-„,,,„.„..,,,,,.„.„,,,,,..,,,,,..... . � S , 2 ...,:,„,,,,,, yN a ? 3.}(I P i�fj� k ���3 2 s- s ,' ,�}=,sb 'fi��" q`�f syr�� sa t s 6 %�r t leW ` 4i14::. .� 4�t of t!ii SprinkFL COMMERCIAL FIRE SPRINKLER CONNECTIONS Product Submittal _._ . 1 ,, gt`,� ....... 8,,..... gyp,, ekw111 iii / ill ��+e ..----7-------....•....,.......,_„...„. , r , , . . . 0,, ... ......„.....„......_ . i. '.... . , ...,., / i b a ... / �� __ , . ./, A PART OF P ,: if atkore 13 Mill Oil ,” FLEXIBLE HOSE - NON BRAIDED a lg�` x L ClaUS (� 1 LISTED r C) I �� 4tili r(,,h�,l, If,hi ia1��te ni.l• t',li�.i t�li,t�i�.,ti,�.i1 i _ Oa: -- S�,N,, ;'1S„, ,i?,�,4f nr,1�. i,i itienr ,�I ' •' - j` �. _ , i. t1] �1 w,,ti, y,mu. k 1. �l „ NO. DESCRIPTION NO. DESCRIPTION ''4; 10-'.. Flexible Hose 7/8" Nominal Diameter 5 .'i e 2 Ring 6 Reducer • 3/4" 3 Washer 7 Plastic Cap ''P 4 Slip Nut FLEXIBLE HOSE - BRAIDED 4< a.. L C®uS LISTED • aaraavro • _ .. ` 1011.0,... it i 0 10..,11%'..0.11.1.i.. ail'd�,ili140.14'040.14116;.64'14 4_ I: _ ' - IFS 11 at d NO. DESCRIPTION NO. DESCRIPTION 1 Flexible Hose 7/8" Nominal Diameter 5 Nipple J 2 Ring 6 Reducer 1/2"or 3/4" 3 Washer 7 Braid sr1 4 Slip Nut 8 Plastic Cap BRACKET ASSEMBLY ci- -(-.) NO. DESCRIPTION NO. DESCRIPTION 1 24"or 48" Support Bar 4 Hex Screw `'.`, 2 Center Bracket Assembly 5 Wing Bolt 3 Clamp MATERIAL SPECIFICATIONS Corrugated Flexible Hose:SS304 Support Bar:G90 Galvanized Steel SEAL:EPDM Clamp and Center Bracket Assembly:G90 Galvanized Steel SLIP NUT AND NIPPLE:Zinc-Plated Carbon Steel Hex Screw and Wing Bolts:Zinc-Plated Carbon Steel Slip Nut and Nipple:Zinc-Plated Carbon Steel Optional Tamper-Resistant Screw:Zinc-Plated Carbon Steel BRAID AND BRAID RING:SS304 '...: .-;'' Limite. Warranty i. SprinkFLEX LLC warrants that its products will be free from defects in materials and workmanship under normal conditions of use and service for a period of one year from date of sale. Our obligation under this warranty is limited to repairing or replacing any product that is returned to us with transportation charges prepaid within one year after the date of original r sale and that our examination shows to our satisfaction to have been defective in materials or workmanship under normal ,;, conditions of use and service. The decision as to whether to repair or to replace any product shall be made by us, and any Erepair shall be made at our facility. Notwithstanding the foregoing, the following are specifically excluded from the coverage <. of this warranty: (a)the sprinkler head of any SprinkFLEX LLC product, but SprinkFLEX LLC hereby assigns to the original purchaser of any such product the right to enforce the warranty, if any, issued by the manufacturer of such sprinkler head; (b) defects resulting from ordinary wear and tear, of any SprinkFLEX LLC. Product; r, (c) products that have been altered in any manner by the buyer or by anyone other than SprinkFLEX LLC.; (d) products that have been subjected to misuse, abusive use, or damage by accident or casualty; (e) products that have been installed or used in a manner contrary to our specifications, instructions or recommendation; (f) products that have been installed or used in a manner that is not in compliance with all applicable requirements of any code, law, regulation or rule of any federal, state or local governmental or industry authority; and (g) products that have not been inspected and maintained in accordance with our specifications, instructions or recommendations, including, without limitation, our recommendations as to following the inspection and maintenance standards published by the National Fire Protection Association (NFPA); and S I, i; (h) products that have been affected by Microbiologically Influenced Corrosion (MIC). ' This warranty is not assignable and shall benefit only the original purchaser of a SprinkFLEX LLC product. If any provision 0,,j , hereof or any portion of any provision shall be held invalid, the remainder of this Limit W r ed ar anty shallnot be affected �; ;: thereby, and all provisions of this Limited Warranty shall remain valid and in full force and effect to the fullest extent permitted by law, ' THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, WARRANTIESk-" • €, MERCHANTABILITY AND WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NOTWITHSTANDING ANY PROVISION TO THE CONTRARY HEREIN OR ANY APPLICABLE LAW TO THE CONTRARY, IN NO EVENT SHALL SPRINKFLEX LLC, BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES WHATSOEVER, WHETHER ARISING FROM ANY BREACH OF THIS LIMITED WARRANTY OR OTHERWISE ARISING G ' FROM OR IN CONNECTION WITH THE USE OR OPERATION OF, OR ANY DEFECT IN, ANY SPRINKFLEX, LLC. PRODUCT, OR OTHERWISE. The risk of damages from any breach of warranty with respect to injury to any person will be born by the purchaser of SprinkFLEX LLC. k p. y {f 9 1 ii',:.;::',41, F.} i '7'4', a �. ' 1sfor, f;':',,'„,_ ''''"7 ,n� ;,, :' r:',1," 43 - y s`iSP:i�ik rx� "a'i'F kgs i°' t'3 �'a -..,-,,-,."-:!:,,Iii, } ,- d k ! 3,t ,2 '- , May 9, 2013 Check Valve 815a ® EASY RISER® SWING TECHNICAL DATA CHECK VALVE MODELS E-1 & F-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Easy Riser® Swing Check Valve is a general purpose rubber-faced check valve approved for use in fire service systems. The valve is for use in wet system risers, preaction system risers and wherever a check valve with a drain connection and gauge connections can be utilized. When used with a flow switch on wet pipe systems not requiring a mechanical / 01051 alarm, the Easy Riser®Swing Check Valve may replace an alarm check valve. 1-A Features 1. Ductile iron body for less weight and extra strength. • 2. Rated to 300 psi (20.7 bar)water working pressure. 3. Rubber-faced clapper hinged to access cover for quick removal and easy servicing.All moving parts can be serviced without removing the valve from the installed position. 4. With the cover/clapper assembly removed, clapper rubber replacement requires re- moval of only one screw. 5. Valve housing tapped for inlet and outlet pressure gauges, and system main drain. 1-B Accessories 1. 300 PSI (20.7 bar)Trim Packages Trim Packages include: A.All necessary nipples and fittings B. Main Drain Ball Valve C. Necessary gauges 2. 175 psi (12 bar) ESFR Preprimed Preaction System Trim for use when the F-1 Easy Riser Check Valve is installed with the ESFR Cold Storage System. 3. 175 psi (12 bar) ESFR Bypass and Drain Trim for use when the F-1 Easy Riser Check Valve is installed with the ESFR Cold Storage System. 2. LISTINGS AND APPROVALS: For Cold Storage application, use Easy Riser Preprimed Preaction Trim and Bypass and Drain Trim, see page 48a-d. cULus Listed: HMER FM Approved: Single Check Valves NYC Department of Buildings: MEA 89-92-E, Vol. XI VNIIPO (250 psi (17.2 bar) MWP) CE: Pressure Equipment Directive 97/23/EC (250 psi (17.2 bar) MWP) 3. TECHNICAL DATA Specifications: Standard Flanged Connections:ANSI B16.42 Class 150 (mates with ANSI Class 125 and Class 150 flanges). Standard Grooved Connections:ANSI/AWWA C606 Viking Technical Data may be found on The Viking Corporation's Web site at Drain outlet: 2-1/2"and 3" valves-one 1-1/4" (32 mm) NPT; 4", 6"& 8"valves-2" http://www.vikinggroupinc.com. (50 mm) NPT The Web site may include a more recent edition of this Technical Data Page. Gauge Outlets: two 1/4" (8 mm) NPT Other Outlets: two 1/2" (15 mm) NPT Systems with water working pressures above 175 psi (12 bar) may require extra-heavy pattern fittings. Viking Easy Riser® Swing Check Valve flanges are Ductile Iron ANSI 816.42, Class 150, with a maximum water working pressure of 300 psi (20.7 bar).ANSI B16.42, Class 150 flanges are NOT compatible with ANSI Class 250 or Class 300 flanges. To mate the Easy Riser®Swing Check Valve with ANSI Class 250 or Class 300 flanges, use the grooved-inlet/grooved-outlet style installed with listed grooved/flanged adapters of the appropriate pressure rating. For piping with grooved connections, the grooved-inlet and/or grooved-outlet style Easy Riser®Swing Check Valve may be installed with listed grooved couplings of the appropriate pressure rating. FOR THE VIKING ESFR COLD STORAGE SYSTEM: • Uses only 4", 6", or 8" size Model F-1 Easy Riser Check Valve • Uses Easy Riser Preprimed Preaction Trim and Bypass and Drain Trim (refer to data page 48a-d for trim sets used in this ap- plication). • Uses the Viking Automatic Pressure Control System Form No. F_011189 Replaces page 815a-g, dated May 31, 2012. (Added Table 3, Trim Package Part Numbers.) May 9, 2013 Check Valve 815c ® EASY RISER® SWING TECHNICAL DATA CHECK VALVE MODELS E-1 & F-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. Use the appropriate wrench to loosen and remove cover screws (14), and remove cover and clapper assembly (2-11). 5. Inspect water seat (12). Wipe away all contaminants, dirt, and mineral deposits. DO NOT use solvents or abrasives. 6. Inspect cover and clapper assembly (2-11) and cover gasket (13). Test the hinged clapper (8) for freedom of movement. Renew or replace damaged or worn parts as required. CAUTION: NEVER APPLY ANY LUBRICANT TO SEATS, GASKETS, OR ANY INTERNAL OPERATING PARTS OF THE VALVE. PETROLEUM-BASED GREASE OR OIL WILL DAMAGE RUBBER COMPONENTS AND MAY PREVENT PROPER OPERATION. 7. When internal inspection of the Easy Riser"' Swing Check Valve is complete, perform step 6 of paragraph 11. MAINTENANCE to re-install cover and clapper assembly (2-11). 6-B. Maintenance (Refer to Figure 1.) FOR THE VIKING ESFR COLD STORAGE SYSTEM, REFER TO DATA PAGE 45a-j FOR MAINTENANCE INSTRUCTIONS. 1. Perform steps 1 through 5 of paragraph 6-A, FIVE-YEAR INTERNAL INSPECTION. 2. To replace clapper assembly (3, 6-11): a. Remove the cover screws (14) from the cover(2) using a Socket Wrench with a 9/16" socket. b. Remove the cover and clapper assembly (2-11) from the valve. c. Remove the cover gasket (13) by sliding it over the clapper assembly. d. Remove the existing clapper assembly (3, 6-11) from the cover assembly (2): i. Remove one of the retaining rings (5) from the clapper hinge pin (4) using a flat head screwdriver. ii. Remove the clapper hinge pin (4) from the cover and clapper assembly. This will allow the clapper assembly (3, 6- 11) to be removed from the cover assembly (2). e. Install the new clapper assembly (3, 6-11) onto the cover assembly (2): i. Make sure the clapper rubber(9) is facing opposite the direction of the flow arrow on the inside of the cover(2). ii. Line up the holes of the cover assembly (2) and the clapper assembly (3, 6-11) and insert the hinge pin (4). iii. Install the retaining ring (5) onto the hinge pin (4). iv. Install the cover gasket (13) onto the new cover and clapper assembly (2-11) by sliding the cover gasket (13) over the clapper assembly (3, 6-11) and lining up the holes with the cover(2). v. To install the new cover and clapper assembly (2-11) into the valve, slide the clapper assembly into the valve with the clapper rubber (9) lined up with the water seat (12). Ensure the rubber retainer (10) fits inside the seat of the valve (pull back slightly and there should be some resistance). vi. Line up the holes of the cover(2) and cover gasket (13) with the valve body (1) and replace the cover screws (14) using a Socket Wrench with a 9/16" socket. 3. To replace the clapper rubber (9): i. Remove the cover screws (14) from the cover(2) using a Socket Wrench with a 9/16" socket. ii. Remove the cover and clapper assembly (2-11) from the valve. iii. Remove the cover gasket (13) by sliding it over the clapper assembly (3, 6-11). iv. Use a 7/32"Allen wrench to hold the button head socket screw (11) in place and remove the jam nut (6) from the clapper rubber(9) using a Socket Wrench with a 9/16" socket. v. Remove the button head socket screw (11) and sealing washer(7) from the clapper assembly (3, 6-11). vi. Remove the clapper rubber retainer(10) from the clapper(8) to free the clapper rubber(9). vii. To install the new clapper rubber(9), position the clapper rubber(9)on the clapper assembly so the grooved edge is facing down. This will allow the clapper rubber retainer(10)to fit up into the grooved edge of the clapper rubber(9). viii. Install the button head socket screw (11) and sealing washer assembly (7) and the jam nut (6) using a 7/32"Allen wrench and a Socket Wrench with a 9/16" socket. ix. Install the cover gasket (13) onto the cover(2) by sliding it over the clapper assembly (3, 6-11). x. Re-install the cover and clapper assembly (2-11) back into the valve, with the clapper rubber (9) lined up with the water seat (12). Ensure the clapper rubber retainer(10) fits inside the seat of the valve (pull back slightly and there should be some resistance). xi. Line up the holes of the cover(2) and cover gasket (13) with the valve body (1) and replace the cover screws (14) using a Socket Wrench with a 9/16" socket. 4. To replace the cover gasket (13): i. Remove the cover screws (14) from the cover(2) using a Socket Wrench with a 9/16" socket. ii. Remove the cover and clapper assembly (2-11) from the valve. iii. Remove the cover gasket (13) by sliding it over the clapper assembly (3, 6-11). iv. Install the new cover gasket (13) by sliding it over the clapper assembly (3, 6-11), onto the cover(2). May 9, 2013 Check Valve 815e NIKING® EASY RISER® SWING TECHNICAL DATA CHECK VALVE MODELS E-1 & F-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com L. B — C t _J I SIZE A B C D E F G** k . 11 ® l 2-1/2" 9" 4-1/2" 2-5/8" 2" 2" Flg—Fig 114 U f _lig ------_ (65mm) (228,6) (114,3) (66,7) (50,8) (50,8) Not Available ® © 14 \J k`I (80mm) 10-1/8"4-13/16" 2-11/16" 2-9/32"2-9/32"7-7/8" 25/32" 11 � � (257) (122,2) (68,3) (58.1) (58.1) (200) (20) 11 FLOW 0 4" 10-5/8" 5-3/16" 3-1/8" 2-1/4" 2-1/4" 9" 15/16" Proper ) (269,9) (131,8) (79.4) (57.2) (228,6) (23,81) L 11 � 0 (100mm (57,2) — __*k s.ollocatonsh.r A 6" 13-3/8"6-13/16" 4-1/16" 2-1/4" 2-1/4" 11" 1" all valve. 1 y,� �1 O (15omm) (340) (173,3) (103.2) (57,2) (57,2) (279,4) (25,4) 7It ...� �\�� 0 8" 17" 8-13/16" 5" ©O �iiiii.�/ ff,w—"� 2-1/2" 2-7/8" 13-1/2" 1-1/8" _ `�• (200mm) (431,8) (223,4) (127) (63,4) (73,0) (342,9) (28,58) © ��►,� 'k!, \\ 0 ® Dimensions shown in parentheses are millimeter. Ca O Illi II -----_ * For availability of Flg X Fig, Flg X Grv, or Gry X Gry options �� ` i refer to Table 1. ©** # : J ` _— O ** 4", 6", and 8" valves are manufactured with sculptured flanges. i I _—_ 1 + t Dimension indicates thickness of flange at bolt holes. I F Figure 1 - Replacement Parts PART NUMBER ITEM E-1 F-1 F-1 F-1 F-1 NO.REQ'D NO. 2.1/2„ 3" 4" 6" 8" DESCRIPTION MATERIAL (DN65) (DN80) (DN100) (DN150) (DN200) 2-1/2" 3" 4" 6" 8" 1 -- -- -- -- -- Body Ductile Iron,ASTM A536 1 1 1 1 1 (65-45-12) 2 -- -- -- -- -- Cover Assembly E-Coated HSLA Steel,A715 and 1 1 1 1 1 Stainless Steel, UNS-530400 3 07576 07576 07576 07576 None Bushing Lubricomp 189 Ryton 2 2 2 2 0 4 05355A 05355A 04900A 04991A 05334A Clapper Hinge Pin Stainless Steel, UNS-S30400 1 1 1 1 1 5 05445A 05445A 05445A 05445A 05369A Hine Pin Retainin. Ring Stainless Steel, UNS-S15700 2 2 2 2 2 6 01755A Clapper Hex Jam Nut#10-24 UNC Stainless Steel, UNS-S30400 1 0 0 0 0 08159 08159 Clapper Hex Jam Nut 3/8"-24 UNF Stainless Steel, UNS-S30400 0 1 1 0 0 08144 08144 Clapper Hex Jam Nut W-20 UNF Stainless Steel, UNS-S30400 0 0 0 1 1 7 -- 08158 08158 08143 08143 Sealing Washer EPDM and Stainless Steel 1 1 1 1 1 8 * Clapper PTFE Coated HR Steel UNS- G10180 1 1 1 1 1 - 9 * * * * * Clapper Rubber EPDM,ASTM D2000 1 1 1 1 1 10 * * * * * Clapper Rubber Retainer Stainless Steel, UNS-S30400 1 1 1 1 1 06595A H.H.C.Screw,#10-24 UNC x 1/2"(12.7 mm)Ig. Stainless Steel, UNS-S30400 1 0 0 0 0 10194 10194 Screw Button Head,Socket, 3/8"-24 UNF x 1/2(12.7 mm)Ig. Stainless Steel, UNS-S30400 0 1 1 0 0 11 Screw Button Head,Socket, 1/2"-20 UNF x Stainless Steel, UNS-S30400 0 0 0 1 0 10308 3/4(19.1 mm)Ig. 10686 Screw Button Head, Socket, 1/2"-20 UNF x Stainless Steel, UNS-S30400 0 0 0 0 1 7/8(22.2 mm)Ig. 12 -- — -- — Seat Brass, UNS-C84400 1 1 1 1 1 13 05354B 05354B 04649B 04992B 05339C Cover Gasket EPDM,ASTM D2000 1 1 1 1 1 01517A 01517A 01517A Screw, Hex Head Cap, 3/8"-16 UNC x Steel,Zinc Plated 4 4 6 0 0 3/4(19.1 mm)Ig. 14 04993A Screw,Hex Head Cap,1/2"-13 x 7/8(22.2 mm)lg. Steel,Zinc Plated 0 0 0 6 0 01922A Scre, Hex Head Cap, 5/8"-11 UNC x Steel,Zinc Plated 0 0 0 0 6 1-1/4"(31.8 mm)Ig. 15 -- -- — -- -- 1/2"(15 mm)NPT Pipe Plug Steel 2 2 2 2 2 —Indicates replacement part is not available •Indicates replacement part only available in a Sub-Assembly listed below. Sub-Assemblies 3,6-11 05499B 08518 08519 08520 08521 Clapper Assembly 9.11 1'3 06343A 08522 08523 08524 08525 Replacement Rubber Kit May 9, 2013 Check Valve 815g NIKIING® EASY RISER® SWING TECHNICAL DATA CHECK VALVE MODELS E-1 & F-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com A✓ LOsv el (..c.,) 1/4'Pipe PWB 1/4•Poe PI uB Y li1/4'x d• • 1/4' d• (1016) Yd <1016> Ai.Gouge Side Outlet08•dt '`d. � 4%%*4, `, Valve )id•roe `' 7---'.--4 /':` r 1/4'Pp1_1/4•w �1-1/4'x Plu .er 4-1/2'(114.3) 1/4•PrlvB ��ii( 4-1/2'((143) B plug ,�, ��1 io 1/4'Pipe (1016) sib Elbow ,\��, ��� 1-1/4• r`'4�-. (101.6) Sltle Outlet V Elbpw `-4��� �d1. PIuB Valve `,II�_ �,- 40 1-1/4• / ,I �1, • [50.8)2 `i °O` v_ r �> � ill2'Elbow 40 PART N0. 13776 ► 1-1/4' PART NO. 13776 W/ 1-1/4 w 2 // Bou votve (508) �/ 2-1/2' IDN651 MODEL E-1 f' 3'IDN80)MODEL r-3 PART N0. (3777 41. EASY RISER PREACTION / EASY RISER PREACTION 4' IDN1001, 6'IDN150) TRIM CHART TRIM CHART 1 0 6 8' IDN200)MODEL F-I 2 (63.5)/2 EASY RISER PREACTION \te/ TRIM CHART / - 1-I/4' Boll Valve ./ r/ / �Boll Volvo Figure 3 For use on Preaction Systems emm 1� :,O4 „Ire ZAK ii TOP VIEW 2-1/2' TOP VIEW 3', 4", 6' OR B' NW/411MODEL E-1 EASY RISER MODEL F-1 EASY RISER -CHECK VALVE CHECK VALVE • . . TOP VIEW I H EASY RISER CHECK VALVE ROTATED 45' 1 I—: _II .14p_ law 1 .....___ 7 IMII� o` • . .........__ \\�1_• A. �� ._ -c- VINO D D --E FRONT VIEW 2-1/2' FRONT VIEW 3', 4', 6', OR 6' SIDE VIEW EASY RISER MODEL E-I EASY RISER MODEL F-1 EASY RISER CHECK VALVE CHECK VALVE CHECK VALVE HORIZONTAL POSITION SIZE A S C D E F G H J 2-1/2' 9' 4-1/8' 6-3/4' 7-5/8' 9' 5-1/2" 5-3/8' 10-7/16' 6-5/8' (65mm) (228,6) (105) (171) (194) (229) (139) (137) (265) (169) 3' 10-1/8 7-1/4" 6-3/4' 7-7/8' 8-7/8' 5-15/16' 5-7/8' 9-7/8' 6-7/16' (80mm) (257) (184) (171) (200) (226) (150) (149) (251) (163) 4' 10-5/8' 7-3/8' 8-3/8' 8-7/16' 11-5/16' 6-3/16'" 6-1/8' 12-11/16' 8-1/16' (100(71m) (270) (187) (213) (214) (287) (157) (155) (322) (205) 6' 13-3/8' 10-1/8' 9-1/8' 9-1/2' 12-1/16' 6-7/8' 6-13/16' 13-3/16' 8-5/8' (150mm) (340) (257) (232) (241) (306) (175) (173) (3:36) (219) 6' 17' 13-1/8' 9-15/16" 10-3/4" 13-1/16' 7-5/8' 7-1/2' 13-15/16' 9-5/16' (200mm) (432) (333) (253) (273) (332) (193) (191) (354) (237) Figure 4 Dimensions In parentheses are millimeter. Dimensions are approxlmate. April 13, 2012 Check Valve 803a NIKING® TECHNICAL DATA SWING CHECK VALVE MODEL D-1 & G-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Swing Check Valve is a general purpose rubber-faced check valve ap- proved for use in fire protection systems. The Swing Check Valve is manufactured with a ductile iron body, brass seat, and a rubber-faced clapper assembly, hinged to a removable access cover for easy inspection and maintenance. The valve may be installed vertically or horizontally with access cover facing up. For availability of flanged-flanged and grooved-grooved options, refer to Table 1.Tapped openings (with plugs) and gauge connections are provided on both the inlet and outlet chambers of the valve. FEATURES 111 A. Ductile iron body for less weight and extra strength. B. Rated to 300 psi (20.7 bar) water working pressure. C. Rubber-faced clapper hinged to access cover for quick removal and easy servic- ing.All moving parts can be serviced without removing the valve from the installed position. D. With the cover/clapper assembly removed, the clapper rubber replacement re- quires removal of only one screw. E. Can be installed vertically or horizontally with access cover facing up. 2. LISTINGS AND APPROVALS cULus Listed: Guide No. HMER FM Approved: Single Check Valves NYC Department of Buildings: MEA 89-92-E, Vol. XI 3. TECHNICAL DATA Specifications: Rated to 300 psi (20.7 bar) water working pressure. Factory tested hydrostatically to 600 psi (41.4 bar). Standard Flanged Connections:ANSI B16.42 Class 150 (mates with ANSI Class Viking Technical Data may be found on 125 and Class 150 flanges). The Viking Corporation's Web site at Standard Grooved Connections:ANSI/AWWA C606 http:/site may incl roupi more . The Web site may include a more recent Tapped Bosses: 2-1/2" (DN65), 3" (DN80) and 4" (DN100): Two 1/2" (15 mm) NPT edition of this Technical Data Page. 6" (DN150) and 8" (DN200): Two 3/4" (20 mm) NPT Material Standards: Refer to Figure 1. Ordering Information: Refer to Table 1 for part numbers and shipping weight. Table 1 Systems with water working pressures above Size Valve Inlet Type Outlet Friction Shipping 175 psi (12 bar) may require extra-heavy pat- Nominal Type Loss* Weight Part No. tern fittings. Viking Swing Check Valve flanges 2-1/2"(DN65) Groove Groove 6 ft.(1.8 m) 16 lbs. (7 kg) 05497C are Ductile Iron ANSI 816.42, Class 150, with a 3"(DN80) Goove Groove 10 ft. (3.1 m) 20 lbs.(9 kg) 08536 maximum water working pressure of 300 psi(20.7 bar). ANSI 816.42, Class 150 flanges are NOT 4"(DN100) FlaTlye Fia"ge 13 ft.(4.0 ,) 47 lbs.(29 ky) 00530 compatible with ANSI Class 250 or Class 300 4"(DN100) Groove Groove 13 ft. (4.0 m) 27 lbs. (12 kg) 08539 flanges. To mate the Viking Swing Check Valve with ANSI Class 250 or Class 300 flanges, use the 0"(DN150) Flaiiyc Fta1iyo 20 ft.(0.0 in) 75 IL..(34 kg) 00542 grooved-inlet/grooved-outlet style installed with 6"(DN150) Groove Groove 20 ft. (6.0 m) 51 lbs. (23 kg) 08543 listed grooved/flanged adapters of the appropriate 0"(DN200) Flange Flange 23 ft.(7.0 m) 135 lbs.(61 kg) 00546 pressure rating. For piping with grooved connec- tions, the grooved-inlet/grooved-outlet style Swing 8"(DN200) Groove Groove 23 ft. (7.0 m) 106 lbs. (48 kg) 08547 Check Valve may be installed with listed grooved 'Expressed in equivalent length of Schedule 40 pipe based on Hazen&Williams formula:C=120. couplings of the appropriate pressure rating. Form No. F_102688 Replaces page 803a-d, dated July 1, 2011. (Revised Figure 1) April 13, 2012 Check Valve 803c NIKING® TECHNICAL DATA SWING CHECK VALVE MODEL D-1 & G-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 6-B. Valve Maintenance (Refer to Figure 1) 1. Perform steps 1 through 5 of paragraph 6.A- FIVE-YEAR INTERNAL INSPECTION. 2. To remove clapper rubber(9): a. Use the appropriate wrenches to loosen and remove the button-head socket screw(11), hex nut(6),sealing washer(7), and rubber retainer(10). b. Remove the clapper rubber (9) for inspection. If the clapper rubber shows signs of wear, such as cracking, cuts, or excessively deep grooves where the rubber contacts the water seat, replace the rubber. 3. To re-install clapper rubber (9): a. Place the clapper rubber(9) over the center hub of the rubber retainer(10). b. Position the retainer(10) (with rubber in place) against the clapper(8) as shown in Figure 1. c. Replace and tighten the button-head socket screw (11), sealing washer (7), and hex nut (6). The sealing washer (7) and hex nut (6) must be located on the top side of the clapper as shown in Figure 1. Do not over-tighten. 4. To remove clapper(8), and/or hinge pin (4): a. Remove the hinge pin retaining rings (5) to free the hinge pin (4) for removal.After the hinge pin (4) is removed, the clapper (8) can be removed. 5. To re-install clapper(8), and/or hinge pin (4): a. Verify that the clapper rubber(9) is in good condition and that it is properly installed. b. Position the clapper(8)with the elongated hinge holes aligned between the holes of the hinge bracket welded inside the cover (2). The system (top) side of the clapper (8) must face the direction indicated by the flow arrow stamped inside the cover (2). c. Insert the hinge pin (4)through the holes at one end of the hinge assembly. Continue to push the hinge pin(4)through the holes at the remaining end of the hinge assembly. d. Re-install the hinge pin retaining rings (5). 6. To re-install cover/clapper assembly (2-11): a. Verify that cover gasket (13) is in position and in good condition. b. Slide the cover/clapper assembly(2-11) into the Swing Check Valve so that the clapper rubber(9) contacts the water seat (12). c. Replace the cover screws (14). Use the appropriate wrench to cross-tighten all screws to the torque value shown in Table 2 for the valve used. DO NOT over-tighten. 7. AVAILABILITY The Viking Swing Check Valve is available through a network of domestic and international distributors. See the Viking Corp. Web site for closest distributor or contact The Viking Corporation. 8. GUARANTEES For details of warranty, refer to Viking's current list price schedule or contact The Viking Corporation directly. Table 2: Torque Values for Viking Swing Check Valve Cover Screws Valve Size Screw Size Torque Values 2-1/2" (DN65) 3/8"-16 HHC 19 ft-lbs 2.63 kg-m 3" (DN80) 3/8"-16 HHC 19 ft-lbs 2.63 kg-m 4" (DN100) 3/8"-16 HHC 19 ft-lbs 2.63 kg-m 6" (DN150) 1/2"-13 HHC 45 ft-lbs 6.23 kg-m 8" (DN200) 5/8"-11 HHC 93 ft-lbs 12.9 kg-m Model:DG 175 PSI Butterfly Valve I Grooved Technical Features ® cOus 4, •Connections:Grooved Ends,AWWA C606 "Pvnoveo LISTED I. "I •Sizes:2-1/2';3';4;6,8" •Approvals:UL,ULC,FM,and California State Fire Marshal •Maximum Working Pressure:175 PSI(Max.Test Pressure:350 PSI) •Maximum Working Temperature:250"F(120"C) •Application:Indoor and Outdoor Use •Factory Installed Supervisory Tamper Switch Assembly r r Component Material Specification a Body Ductile Iron ASTM A536 Nylon-11 Coated j + Indicator Ductile Iron ASTM A536 Handwheel Ductile Iron ASTM A536 Worm Shaft Stainless Steel AISI 410 1 1 Gear Segment Brass ASTM 8584 Fireriser"Model:DG 0-Ring(All) EPDM EPDM Grade E F 4.4' 2.4' 5.9" IIIII 11 NI to 177. gar- T .�.. lI� 1j1 ill , Tyyo II II H C Dimensions:Inches(Millimeters) Size:in/mm A B C D E F G H 2 1/2" 4.1 (105) 3.7(9) 3.8(96.4) 2.9(73) 5.3(135) 5.3(135) 5.0(128) 4" 5.7(145) 4.3(108) 4.5(115.4) 4.5(114.3) 6.9(175) 5.3(135) 5.0(128) 8" 8.0(204) 6.7(170) 5.8(147.4) 8.6(219.1) 9.2(234) 7.6(193) 8.7(220) 1.0(24.2) H:Disc clearance of body surface through end of disc in open position. FIV `1 LCO kiJ a www.fivalcoUSA.com 4 C 0 Model 1011A uanoT Es TD RAI N 0 AN APP® Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other setting available Dimensions Model 1011A - Front View SIZE A B C D E F G H A ye 7 /16" 11/2" 23/1s" 35/8" 33/8" 113/16" 49/16" 63/8" E-1 +INLET (191 mm) (37.5 mm) (57 mm) �I (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) TO 1 F O 1.. 79/is" 11/2" 2�is" 3�8" 3�/s" 113/n" 49/is" 6�/s, DRAIN mog n _� �� r " (191 mm) (37,5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) ~ II � it`��i:��1 I r 11/4 715/16" 111/16" 29/16" 41/4" 35/6" 115A6'' 59/16" 71/2" ' (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) II "�` 11/2,, 81 5/n" 114/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815ii6" 113/16" 31/4" 51A6" 37/6" 2H" 81/4" 107/8" Model 1011A - Plan View (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) A-7 The Model 1011A provides the following... To I __ 111 From the 2013 Edition of NFPA 13 s �ql � Chapter 8.16.2.4.1' Provisions shall be made to properly drain all parts of the system. I t .� `�J :l�l Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) I c \` &8.16.2.4.3 shall be provided with a drain connection having a minimum iii j —�.— size as shown in Table 8.16.2.4.2. 1.-1 Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Orifice Sizes Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a , ; drain capable of accepting full flow... using an approved sight test /a ' /,6 , /2 , /'1 ,5/e ELO*, connection containing a smooth bore corrosion-resistant orifice 3/4ESFR*,and K25** giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be accessible. Materials Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream of Handle Steel the waterflow alarm. Stem Rod Brass Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in Ball C.P. Brass diameter,terminating in a smooth bore corrosion-resistant orifice, Body Bronze to provide a flow equivalent to one sprinkler... Valve Seat Impregnated Teflon® Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less Indicator Plate Steel than 1",at least one of which shall be brass. Relief Valve Bronze Chapter 7.1.2 -a wet pipe system shall be provided with a listed relief valve set Bypass FittingsBrass to operate at 175 PSI or 10 PSI in excess of the maximum system Bypass TubingNylobraid pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than�/2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at Approvals a pressure not exceeding rated pressure of the system. UL and ULC Listed: Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge from the (EX4019&EX4533) (pressure relief)valve FM Approved NYC-BSA No. 720-87-SM IWE 11 A USA Patent # 4741361 and Other Patents Pending G AGF Manufacturing Inc. Job Name: AF 100 Quaker Lane, Malvern, PA 19355 PhoArchitect: Fax: 610-240-4900 Fax: 610-240-4906 Engineer: www.testandrain.com Contractor: 'Available on 11/4"to 2"size units only•"Available on 11/2"and 2"size units only 138b January 6, 2012 NIKING® TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Table 1 - Pipe Capacity for Sizing Air Compressors Table 2 -Air Pressure Settings Pipe Diameter Capacity Air Pressure Setting Water Schedule 40 (1"to 6") Pressure Minimum Maximum US International Schedule 30 (8") Schedule 10 Gal/Ft L/m Gal/Ft L/m PSI bar PSI bar PSI bar 1" DN25 0.045 0.559 0.049 0.608 50 3.4 22 1.5 27 1.8 1-1/4" DN32 0.078 0.969 0.085 1.043 75 5.1 26 1.8 31 2.1 1-1/2" DN40 0.106 1.316 0.115 1.428 100 6.8 30 2.0 35 2.4 2" DN50 0.174 2.161 0.190 2.360 125 8.6 34 2.3 39 2.6 2-1/2" DN65 0.248 3.080 0.283 3.515 150 10.3 38 2.6 43 2.9 3" DN80 0.383 4.756 0.434 5.390 175 12.0 42 2.8 47 3.2 3-1/2" DN90 0.513 6.370 0.577 7.165 4" DN100 • 0.660 8.196 0.740 9.190 200 13.7 45 3.1 50 3.4 5" DN125 1.040 12.915 1.144 14.206 225 15.5 49 3.4 54 3.7 6" DN150 1.501 18.640 1.649 20.477 250 17.2 53 3.6 58 3.9 Supervisory Pressure Switch should be set 5 PSI 8" DN200 2.660 33.032 2.776 30.472 For Metric Units 1 Ft. =0.3048 M, 1 Gal. =3.785E (0.34 bar) below air compressor cut out. 5. The optional Model LD-1 Anti-Column Device may be installed to prevent water accumulation above the dry pipe valve. 6. The prime line connection shall be made upstream of the water supply control valve using 1/2" or larger pipe. B. Air Supply Design Calculating Trip Pressure and Air Compressor Size To calculate the point where the water pressure will overcome the air pressure and trip the valve, divide the static system water pres- sure by the differential (Approximately 5.75:1). Example: Static Water Pressure=64 PSI (4.4 bar) -.Trip Point=64/5.75= 11 PSI (0.76 bar). The dry valve will trip when the air pressure is reduced to 11 PSI. NFPA 13 requires the air supply to be capable of filling the entire sprinkler system to its required air pressure within 30 minutes.A com- mon method of sizing an air compressor is to use the following formula: Compressor Size (cfm) =0.012 x V(gal) Where V=System volume and 0.012 is a common multiplier that will provide 40 PSI (2.8 bar) in 30 minutes. The following formula may be used for air pressures different than 40 PSI: Where: V=Volume Compressor V x P P= Required Air Pressure (Trip Pressure+ 15 PSI) Size (cfm) = T= Fill time (typically 30 min.) 7.48 x 14.7 x T 7.48 =gal. /ft.3 14.7= atmospheric pressure Example: Table 3 - Quick Reference Compressor Size System volume as determined by table 1 =750 gallons System water pressure= 73 PSI (5 bar) Compressor Free Air @ Maximum Gallons in Required air pressure = (73/5.75) + 15=28 PSI (1.93 bar) Size (HP) 40 PSI (cfm) System to Pump to 40 PSI (2.8 bar) in 30 Minutes Compressor Size (cfm) = (750 x 28) = 6.4 cfm 1/6 1.0 90 7.48 x 14.7 x 30 1/3 2.0 180 Therefore, the compressor shall be capable of providing 7 cfm. 1/2 3.1 300 1 5.9 600 138d January 6, 2012 TECHNICAL DATA 6" MODEL G-6000 DRY VALVE NIKING® RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TO FIRE ALARM PANEL NEGATIVE DC 4483 OR NEUTRAL AC GI POSITIVE DC -7..7�1 OR HOT AC r: • 1 f I ilii-je„ r°1) .® I 0 0 ® I�� O O O / KNOB AN ADJUSTMENT ' ;,. ® [7 971 ..g ' -� I !7.IV (107.19[ j12'NPT Figure 3 -Alarm Pressure Switch Wiring .....1 `•8 �, - ,.�, (62.87I '� [s1.80 (Alarm Pressure Switch should be set to 5 PSI (0.34 bar) 3,73 �- 320 (�>9J [8128J P.S40-2 TO FIRE ALARM FIELD ADJUSTMENTS: PANEL 11M11111111111MMI PIE0[0°N aIAIIR{ Alarm Pressure Switch:The operating point of the switch can be adjusted to any point between 4 PSI(0.27 bar)and 8 PSI(0.55 bar) coM' by turning the adjustment knob(s)clockwise to raise the actuation co�M- © point or counter-clockwise to lower the actuation point. r\ r` LOW WITH NORMAL SYSTEM AIR PRESSURE APPLIED HIGH Air Supervisory Switch: The operating point of the switches can 1„-11-„1 -TERMINAL!ImmlINCREAOSE be adjusted to ON PRESSURE WILL CLOSE I any point between 10 PSI (0.7 bar) and 60 PSI (4.1 bar) by turning the adjustment knob(s) clockwise to raise the EOLR actuation point or counter-clockwise to lower the actuation point. DWGw 930.2 The high and low switches are adjusted independently. Figure 4 -Air Supervisory Switch Wiring (High Air should be set to 10 PSI (0.7 bar) above compressor cut out) (Low Air should be set to 5 PSI (0.34 bar) below comperssor cut out) Figure 5 - Pressure Adjustment C. Air Supply Installation 1, Install the required air supply as described in Viking technical data page 105a-e. The size of the compressor and amount of air required should be determined in accordance with Table 1.The air or nitrogen supply to the dry pipe system must be clean, dry, and oil free. 2. Automatic air supplies must be regulated, restricted, and from a continuous source. A Viking Air Maintenance Device should be installed on each system equipped with a tank mounted compressor, plant air or nitrogen. For riser mounted compressors with a capacity less than 5.5 ft3/min at 10 PSI (0.154 m3/min at 0.7 bar), NFPA 13 does not require an air maintenance device. In addition, the use of an air maintenance device with riser mounted compressors can lead to compressor "short cycling". Viking always recommends using a tank mounted compressor with air maintenance device. This can become critical when accelerators are installed on the system. D. Pressure Switch Wiring; Wire the Alarm Pressure Switch (PS10) and Air Supervisory Switch (PS40), and adjust pressure settings as shown in Figures 3-5. E. Air Leakage Test: Perform air leakage test at 40 PSI (2.8 bar)for 24 hours per NFPA 13. If pressure loss of 1.5 PSI (0.1034 bar)or greater occurs, repair leaks. F. Hydrostatic Test: The Dry System, including sprinkler piping and sprinklers shall be hydrostatically tested at 200 PSI (13.8 bar) and maintained for two hours, in accordance with NFPA 13. Systems normally subjected to working system pressures in excess of 150 PSI (10.3 bar)shall be tested at a pressure of 50 PSI (3.45 bar) in excess of system working pressure. G. Placing the Valve in Service: When the dry pipe system is ready to be placed in service, verify that all equipment is adequately heated and protected to prevent freezing and physical damage. 1. Verify that the water supply main control valve supplying the dry valve is closed. 2. Close the prime valve. 3. Open the main drain valve. 4. Drain all water from the dry pipe system. If the system has operated, or if water has entered the system, allow enough time to completely drain the system. 5. Close the main drain valve. 6. Open the flow test valve. 138f January 6, 2012 , NIKING® TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com B. Loss of System Air Pressure: When a sprinkler operates or air pressure is lost, the sensing end of the differential valve loses pressure and the differential valve opens.Prime water is drained from the prime chamber,causing the dry pipe valve to open.filling the sprinkler piping with water.Water from the intermediate chamber of the dry pipe valve pressurizes the sensing end of the PORV, causing the PORV to open.The open PORV vents air pressure from the air supply, preventing the differential valve from closing and re-establishing prime pressure. Air leaves Air leaves sprinker piping sprinker piping \�' and fills with water �� Water �� r..._._...-� Air _ git;liel .. 1 S;; � I A, I,s��0 ► Differential til--' � ' _ IMMIllir '* I/ �i�l• Valve opens r f _� `-er,( A., - ._1- PORV \ !':! L I Ir i ire-',I J f ��le I L■'��. 1 I Nit (`( • lel ) LINO � Pal ■ ■ , ...ULM) Ai L mimpi , _ ._,. _trolrisio ., uNV 0 4 ! . _ I• bil V Iwo Figure 7 - Loss of System Air Pressure 6. INSPECTIONS, TESTS, & MAINTENANCE It is imperative that the system is inspected and tested on a regular basis. The frequency of the inspections may vary due to contami- nated water supplies, corrosive water supplies, corrosive atmospheres, as well as the condition of the air supply to the system. For minimum testing and inspection requirements, refer to NFPA 25. In addition, the Authority Having Jurisdiction may have additional testing, and inspection requirements that must be followed. Viking does not require internal inspection of the valve as part of routine inspection and testing. Internal maintenance is generally only required for valve repairs and internal component replacement. Maintenance of the Model G-6000 Dry Valve shall be conducted in accordance with the instructions in section 6.111. WARNING: DO NOT SEPARATE THE COVER AND BODY SECTIONS UNLESS THE VALVE IS LEAKING. I. INSPECTION Weekly inspection is recommended. If the system is equipped with a low air(or nitrogen)alarm, monthly inspections may be adequate. 1. Check pressure gauges located on the supply side and system side of the dry valve. Verify that the proper ratio of air (or nitrogen) pressure to water supply pressure is being maintained. Refer to Table 1. 138h January 6, 2012 NIKING® TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5. If the dry valve being tested is equipped with a Viking Model E-1 Accelerator, performing step 6 of this test will cause the accelerator to operate. A burst of air from the vent in the bottom of the accelerator will indicate operation of the accelerator. However,with the water supply main control valve CLOSED and the flow test valve OPEN,operation of the accelerator should not trip the dry valve. 6. Low Air Alarm Test: a. Verify that the water supply main control valve is closed and the flow test valve is open. b. Gradually open the main drain valve on top of the dry valve to simulate operation of the dry system. Observe and record the pressure at which the low air alarm operates. 7. Close the main drain valve. 8. Perform steps 1 through 15 of section 4.G - Placing the Valve in Service. Trip Tests Partial Flow Trip Tests are conducted with the water supply main control valve partially closed to minimize the amount of water enter- ing the system during the test. Performance of a Partial Flow Trip Test is recommended during warm weather at least annually except when a Full Flow Trip Test is conducted. Partial Flow Trip Tests may verify operation of equipment and devices but do not simulate operation of the system in fire conditions. Full Flow Trip Tests are conducted with the water supply main control valve fully open.The dry valve is operated by opening the system test valve to simulate the opening of a sprinkler in fire conditions. When the dry valve operates, the sprinkler piping will be flooded with water. Performance of a Full Flow Trip Test is recommended during warm weather at least once every three years. More frequent testing may be required by the Authority Having Jurisdiction. A. Full Flow Trip Test 1. Notify the Authority Having Jurisdiction and those in the area affected by the test. 2. Fully open the flow test valve (located on the base of the dry valve) to flush away any accumulation of foreign material. 3. Close the flow test valve. 4. Record water supply pressure and system air pressure. 5. Open the remote system test valve to simulate operation of the dry system. Record: a. Elapsed time from opening of the test valve to operation of the dry valve. System pressure when the dry valve oper- ated. b. Elapsed time from opening of the test valve to development of full flow of water from the system test connection. c. Any other information required by the Authority Having Jurisdiction. 6. Verify that alarms operate properly. 7. Allow water to flow from the system test connection until it appears clear and clean. 8. When test is complete, close the water supply main control valve. 9. Perform steps 1 through 15 of section 4.G - Placing the Valve in Service. 10.Verify that the water supply main control valve is open, and all other valves are in their normal operating position. B. Partial Flow Trip Test 1. Notify the Authority Having Jurisdiction and those in the area affected by the test. 2. Record water supply pressure and system air pressure. 3. Fully open the flow test valve (located on the base of the dry valve) to flush away any accumulation of foreign material. 4. CLOSE the water supply main control valve as far as possible while maintaining full flow from the flow test valve. CLOSE the flow test valve. 5. Open the main drain valve to simulate operation of the system. 6. Note (for records) water supply pressure and system air pressure when the dry valve operates. 7. CLOSE the water supply main control valve and OPEN the main drain IMMEDIATELY, when test is complete. 8. Perform steps 1 through 15 of section 4.B - Placing the Valve in Service. 9. Verify that the water supply main control valve is open, all other valves are in their normal operating position. III. MAINTENANCE 1. Close the water supply main control valve, placing the system out of service. 2. Open the flow test valve located in the base of the dry valve. 3. Close the air(or nitrogen) supply to the dry system piping. 4. Close the priming valve. 5. Relieve all pressure from the dry system piping. If the system has operated, open the main drain valve to allow the system to drain completely. 6. Confirm that all three pressure gauges read zero. 138j January 6, 2012 NIKING® TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Air Pressure 12 Section or 6 Part Number 17048-1 includes: Supervisory -� Schedule l0 Pipe 1 Model G-6000 Valve Switch ...,41111:1j ' and 6• Coupling I 1 Model G-6000 Dry Trim *1 j •` *�C 1 12" Section of Schedule 10 Pipe with ` Coupling t t-\ �w }l�1 1 Air Pressure Supervisory Switch (PS40 2A) Alarm � a 0 :,1�'I?' �1. 1 Alarm Pressure Switch (PS10-2A) Pressure ���,,�=' • ,t' ��i Water Supply Switch e 0 "' (, �1_II�;���. .1.--.. ..41-1 1 pp y Control Valve RIPPO‘ i1 ��!♦\� w---,�quA ; G-6000 Valve ���`46 �: and Trim ,,:t-.-37;.4-f at, Lam* 1 1,101 �ll 1111� �! Water Supply •'� tli�`��� ,�l•! Iu d. Control Valve `/404 alve ,� `/ si ipt Figure 8 - Complete Assembly Model E-i Accelerator (Vent to 0 Atmosphere) 4� `�. `��' ' �!C --.•. Accessories: / kile C �) t' �, �l' 08055 Model E-1 Accelerator -4(t'=. rr`�� 10i��,r�t,4' r. 14800 Model LD-1 Anti-Column Device '�`��1 Vi�0� ` �� 17056 Drain Manifold \ w' �,�,;►_� Figure 9 - Optional Accessories I Nib": 1117-H4,4_,_iit:11 izoill :Imoi � ice' 17,-;.rriwqr-crptial %Tao i) (1IJ#Sl! I`14-tftV lir 0 ih1,6 ,f,,,„A. te.4,.... ., .4r. y ► �a r.W1 —^ ' Drip Grooved 41. IModel LD-i �`/j_% Culirp Coupling Anti-Column �� � Device '` tin.-120 ^ Check WIWI II ///\� a Valve 1111r( (0.1.!'. our(4,7, ➢rain Manifold Drain Manifold `1� '�, Detail 1381 January 6, 2012 NIKING® TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com i ,r O • ,iii • •ir''i 0 I _SII 1116, _ 1, 4,77,em!„......mie—siqi, 1.Thr--....11•, !.. e4....,.„'O.' tif 1• •Il / niiiii ,.i unit t�i�":il� O �1i 'i 1�1 ���/, / Oit' - i;, �4coto �— , �`� 7/ li„,. 1 I MY -0 j 3 ., II 41111 140 29, IF 0 Figure 11 - G-6000 Valve Components List/Replacement Parts Item Part Number Number Number Description Material Required 1 -- Body 64-45-12 Ductile Iron 1 2 -- Seat UNS-S30400 Stainless Steel 1 3 -- Anaerobic Adhesive -- 1 4 17081 Prime Chamber Assembly Brass, EPDM, Nitrile, 304 Stainless Steel, Bronze Alloy 1 5 0-Ring EPDM 1 6 0-Ring EPDM 1 7 16299 Coupling UNS-S17400 Stainless Steel 1 8 16552 Check Diaphragm EPDM 1 9 -- Cover 65-45-12 Ductile Iron 1 10 08083 1/2-13 x 1-1/2"HHS UNS-S30400 Stainless Steel 16 11 -- Data Plate Aluminum 2 12 -- Tack Alloy Carbon Steel 4 --Replacement part is not available. 'Indicates part is available only in a Sub-Assembly,as indicated below. Sub-Assembly 5, 6 17445 0-Ring Replacement Kit (Refer to 0-Ring Replacement Bulletin Form No. F_120611 for instructions.) THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_022111 Replaces page 138a-m, dated June 1, 2011. (Revised the replacement parts list and Figure 11.) January 6, 2012 Preaction 330c NIKING® 2" MODEL G-2000P TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC/PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Table 1 - Pipe Capacity for Sizing Air Compressors System Pressure Pipe Diameter Capacity Table 2 - Air Pressure Settings Up to 175 PSI 175 PSI (12 bar) Schedule 40(1"to 6") g (12 US International Schedule 30(8") Schedule 10 bar) to 250 PSI (17 bar) Gal/Ft L/m Gal/Ft L/m For Systems with Tank-Mounted Compressors: 1" DN25 0.045 0.559 0.049 0.608 Air Maintenance 30 PSI 50 PSI 1-1/4" DN32 0.078 0.969 0.085 1.043 Device (2.1 bar) (3.45 bar) 1-1/2" DN40 0.106 1.316 0.115 1.428 Air Supervisory Switch 25 PSI (1.7 bar) 45 PSI (3.1 bar) 2" DN50 0.174 2.161 0.190 2.360 For Systems with Riser Mounted Compressors: 2-1/2" DN65 0.248 3.080 0.283 3.515 Compressor 30 PSI (2.1 bar)/ 50 PSI (3.45 bar)/ 3" DN80 0.383 4.756 0.434 5.390 On/Off Switch 40 PSI (2.8 bar) 60 PSI (4.1 bar) 3-1/2" DN90 0.513 6.370 0.577 7.165 Air Supervisory 4" DN100 0.660 8.196 0.740 9.190 Switch 25 PSI (1.72 bar) 45 PSI (3.10 bar) 5" D N 125 1.040 12.915 1.144 14.206 6" DN150 1.501 18.640 1.649 20.477 Table 3 - Quick Reference Compressor Size 8" DN200 2.660 33.032 2.776 30.472 Compressor Free Air @ Max System Size to For Metric Units 1 Ft. = 0.3048 M, 1 Gal. = 3.785L Size (HP) 40 PSI (2.8 bar) Pump to 40 PSI (2.8 bar) a valve house (enclosure) with adequate heat around the (cfm) in 30 Minutes (Gal) G-2000P Valve and trim. Freezing temperatures will damage 1/6 1.0 90 the G-2000P Valve. When corrosive atmospheres and/or 1/3 2.0 180 contaminated water supplies are present, it is the owner's 1/2 3.1 300 responsibility to verify compatibility with the G-2000P Valve and associated equipment. 1 5.9 600 4. The Viking Model E-1 Accelerator should be installed at the location indicated in Figure 1 when required. B. Air Supply Design 1.Air Compressor Size Viking recommends tank-mounted air compressors for Double Interlock Electric/Pneumatic Release Preaction Systems. The pneumatic actuator requires at least 30 PSI (2.1 bar) of air pressure be established within the piping network for systems with water pressure up to 175 PSI (12.1 bar) and 50 PSI (3.45 bar) of air pressure for systems with water pressures up to 250 PSI (17.2 bar). NFPA 13 requires the air supply to be capable of filling the entire sprinkler system to its required air pressure within 30 minutes.A com- mon method of sizing an air compressor is to use the following formula: Where: Example: V=Volume System volume as determined by table 1 = 750 gallons Compressor V x P P= Required Air Pressure Required Air pressure= 30 PSI Size(cfm) = T= Fill time (typically 30 min.) (750 750 x 30) 7.48 x 14.7 x T 7.48 =gal./ft.3 Compressor Size (cfm) _ =6.8 cfm 14.7=atmospheric pressure 7.48 x 14.7 x 30 Therefore, the compressor shall be capable of providing 7 cfm. 2. Nitrogen Cylinder Gas Supoy (See Figure 1) Nitrogen may be used in place of air compressors. Nitrogen is supplied in pressurized cylinders in various sizes and pressures. Some of the most common are 122 Cu. Ft. at 1,900 PSI (3,455 L at 131 bar), 225 Cu. Ft. at 2,100 PSI (6,372 L at 145 bar), and 280 Cu. Ft. at 2,300 PSI (7,930 L at 159 bar). When nitrogen cylinders are used as a primary air supply, spare cylinders should be furnished and located at the valve location. To determine the approximate amount of nitrogen to be furnished. the following formula may be used: English Units Metric Units Vs x P Where: Vs x P Where: Vc= Vc=Volume of Cylinder(ft3) _ Vc=Volume of Cylinder(L) 100 P= Required Nitrogen Pressure (PSIg) Vc 108 P= Required Nitrogen Pressure(bar) V=Volume of System (gal) V=Volume of System (L) January 6, 2012 Preaction 330e ® 2" MODEL G-2000P NIKINGTECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Air Supply Air Pressure Air Pressure / Connector Air Pressure ,i01/ Gauge and Valve Supervisory Switch Supervisory l 1 Switch � ��r(., �� \ Check ir► *to. Air +� Valve Air Supply Pneumatic i,. `meq `v Pressure LiPPrime (111 , ,I/ Connection Actuator `"% !b', 1GV9vee & "� / Prime IlVI e ie ressur�t _� CIL%. 1 Pressure ci,'�Gauge Valve& C,� l� /�—Nip 1/ ' li eumatic Gnu e & ' oto , �(lr( %�, Ali! Actuator Va " NC Emergency �r ��,�71T(� ��;I ' 0"-.... Solenoid Release ��ci� ,li�i1�� ` k;(�^ j' NCValve ,ter'�^ •` O�/�, PORV ....1.,- �� Solenoid � ' ,�`������ (l Valve �4101F, Alarm to ily i�!! f I11 ��'1 ., � Einer.- �Cfr- ,lt-.�����1 � "'Pressure � "��l"T(�j'(S ►"� Relei- 001-„�f ��ly ��1Switch ii, l,Wirire at&# 4\� - ,', rgr �,-la,.INiiiiii i�,,h�/`'= f E ;�. � jr reams � PORV `` %Zooi 1 `.1i` Check .��,.„ij �,�`r./ -u�irsee- r0”, 0Valve !'1ow, im r►��r�-,; Check Drip plre#H4 Flo11 0 Main ; ,��`^- 1 Valve Check �� v rri,Al Flow .,I, .5)211011. -000. Test��0 Drain Su l/Alarm' —kla.,Y� Test �\r�( < K +Valve Supply Prime Line •_•� ✓. ,c Test 1.17' Valves / `r( �� ,'r' �� Pressure r ' ■i connects < Valve v��'i �� ) ��i� , Supply Pressure Gauge & lenotrici . r upstream of ( ��=I(`l Gauge & Valve Valve s'`&11 '(`; Water Supplyliv ( Alarm Prime . (�\��� Water Supply �� Valve Control Valve �: Pressure Control Valve DripCheck Switch Main Restriction Valve Drain Strainer Cup Figure 5 - Trim Components 6. Close the main drain valve. 7. Open the priming valve. Prime water pressure will enter and expand the valves internal diaphragm assembly onto the valve seat, effectively closing the valve. Verify prime pressure has been established on the prime pressure gauge. 8. Establish air pressure on the system. 9. Verify that no water flows from the drip check when the plunger is pushed. 10.When the priming pressure has been verified as being established, slowly open the water supply control valve (not shown). 11. When flow is developed from the flow test valve, CLOSE the flow test valve. 12. Fully open the water supply main control valve. 13.Secure all valves in their normal operating position. 14. Reset the release control panel. 15. Notify Authorities Having Jurisdiction and those in the affected area that the system is in service. 16.The system is now fully operational. G. Operational Test: An operational test shall be performed on the system in accordance with NFPA 13. Refer to Section 6 for Inspection and Operation Test Procedures. January 6, 2012 Preaction 330g NIKING® 2" MODEL G-2000P TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC,PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com B. Fire Condition: When the detection system operates,the normally closed solenoid valve is powered open.At this point,the prime water is still held in the prime chamber by the closed pneumatic actuator. When a sprinkler operates, air pressure is lost on the sensing end of the pneumatic actuator, causing the pneumatic actuator to open. With both the pneumatic actuator and solenoid valve open, prime water is drained from the prime chamber, causing the G-2000P Valve to open, filling the sprinkler piping with water. Water from the intermediate chamber of the G-2000P Valve pressurizes the sensing end of the PORV, causing the PORV to open. The open PORV prevents water pressure from building in the prime chamber should the solenoid or pneumatic actuator close. q 1. Detector operates // \N 0 AN ‘111111111. Nip .. 0 dei Vii/ _ 2. Sprinkler 'e' ('L Operates, Draining To Air 'y To the Air in the Piping Supply di lir Riser f416, 3. Low Air Alarm ,, r f . , �. Activates tel= 0 `rr:- 0 6. Valve opens, 4. Pneumatic 11/ �0 _i ills er piping Actuator Opens v ,��- Ohl►] fills with water -.:1. 1 11111 ,‘ �iN ■ ,411111414 it fil IP i7-7 it NO:: /�'� , 5. Prime _ •�•` " .•�`, .s.„ Chamber ?lri_ _ ii'C '% 1 ,i; 4a1„A ),01 ' Drains un,_ —�td4----Z-11-.'‘:,. ' �•11�JII'; � f �( k`_ ��� i� I , . (**A stom -" . Rivve l � ��►� • 1 '1 I -illi i• (410,,,:4,i '�ri� r 41 1D _ o (�%,'' vs„ Air lii , \j 11, 4 Ig �� Air • Figure 7 - Fire Condition January 6, 2012 Preaction 330i NIKING® 2" MODEL G-2000P TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC/PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 6. The cover(9) and trim that is still connected may now be removed from the valve body. (It may be necessary to pry the valve open as the diaphragm may bond itself to the cover(9) and body over time.) C. Removing/ Replacing the Check Diaphragm: (Refer to Figure 11) 1. The check diaphragm (7) may be lifted from the valve body (1). 2. If necessary, replace the check diaphragm (7). D. Inspecting the Prime Chamber and Coupling for Leaks: (Refer to Figure 11) If desired, it is possible to set the G-2000P Valve and inspect for leaks with the cover (9) removed. 1. Slowly open the prime valve. 2. With prime water established, partially open the main water supply control valve. 3. Visually inspect the inside of the G-2000P Valve for leaks. E. Removing/Replacing the Prime Coupling: (Refer to Figure 11) 1. Open the 1/2" union on the prime line. 2. Using a wrench on the flats of the coupling (6), remove the coupling (6) from the valve body (1). 3. Inspect the coupling (6) and 0-rings. Replace if necessary, using the instructions in 0-Ring Replacement Bulletin F_120611. F. Removing/Replacing the Prime Chamber Assembly: (Refer to Figure 11) 1. The prime chamber assembly(4) is now held in place by two flanges on the outside diameter of the assembly. Slide the prime chamber assembly (4) toward the prime line and remove from the body. 2. Inspect and replace if necessary. 3. Inspect the seat. The seat should be clean and free of foreign material. If the seat is damaged, the G-2000P Valve must be replaced. G. Re-Assembling the Valve: (Refer to Figure 11) 1. Place the prime chamber assembly (4) in the valve body (1). Make sure the two flanges are positioned in the groove. 2. Thread the prime coupling (6) into the valve body (1). Make sure the end of the prime coupling (6) is inserted into the prime chamber assembly (4). 3. Lay the check diaphragm (7) into the valve body (1). 4. Position the cover(9) onto the valve body (1), and install and tighten the cover screws (8). 5. Re-install any trim that was removed. 6. Place the valve in service by following the steps in Section 4.F. 8. AVAILABILITY The Viking Model G-2000P Valve is available through a network of domestic and international distributors. See the Viking Corp. Web site for closest distributor or contact The Viking Corporation. January 6, 2012 Preaction 330k ® 2" MODEL G-2000P NIKIN4 TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC,PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com —2232 [577)— -- - 17-5[ 436) 916 [233] Ilk i D;/Ill C�I��~l:II�E?_ INI i BIM I :MI -in I I 1:±' III .... ein , ee S—T-1 E la NI /111111 1 I. 016 [509] m�� (.;�Q D=I� leit0iricA-iLgmigirlmiWia..iwimliitr4iil 1 7-. mit Illa 101 [255] oi �billl�ra � -_- , _i_ t� 16 — �07 �. I► loll 'EcylErl.wwfi Et LrE6103311111111 CI ill Ill Q D ,� l #1i? '!!q.li�� I 23 ■ ' I � u�[170] iil 4 3��2 [272] III co - - t . 1 . . I, Q-D el 1--815 [227]6 [152:0-- 6-3 S :� 16 [157] X16 [186) Figure 10 - Installation Dimensions October 25, 2010 Sprinkler 105a VIKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suit- able for use in areas subject to freezing. The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation.They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and tem- perature ratings to meet design requirements. The special Polyester coating has been investigated for installation in corrosive atmospheres and is cULus listed as corrosion resistant as indicated in Approval Chart 1. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Viking Technical Data may be found on Specifications: The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar) http://www.vikinggroupinc.com. Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to The Web site may include a more recent 100 psi (6.89 bar) edition of this Technical Data Page. Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support (Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Form No. F_031793 Replaces page 105a-f, dated August 12, 2010. (Revised sprinkler materials.) October 25, 2010 Sprinkler 105c NII<ING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy (patents pending), and White Polyester Corrosion-Resistant Coating3.4: White Polyester in all temperature ratings Footnotes " The sprinkler temperature rating is stamped on the deflector. ' Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester coating has passed the standard corrosion test required by the approving agencies indicated in Approval Chart 1.These tests cannot and do not represent all possible corrosive environments.Note:This coating is NOT corrosion proof. Prior to installation,verify through the end-user that the coating is compatible with or suitable for the proposed environment. Polyester coating is applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester coatings. 4 When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For- 'A' Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2' (12.7 mm) between 1-1/2' and 45-1/2' (38.1 mm and 1,156 mm). NOTE' The deflector will be located approximately 3-7/16' (87.3 mm) below the ceiling. with 1' (25.4 mm) upward and 1' (25.4 mm) downward adjustment. Deflector at minimum distance below ceiling. IIii NOTE To locate the deflector ��� at the minimum distance below the ceiling, with I I no downward adjustment A Minimum ceiling opening r-7/l6' available, order the diameter: 1-3/4' (44.5 mm). • (61.9 mm) dry pendent sprinkler Maximum ceiling opening I Minimum 1' (25.4 mm) shorter diameter: 2-1/4' (57 mm). than the 'A' dimension. " N"I-I - 13/16' 1�1 NOTE: Finished I/ ® (20.6 mm) NIII1PP To locate the deflector Ceiling at the maximum distance 4-7/16' below the ceiling, with 1-1/2'- Sleeve finish (112.7 mm) no downward adjustment (38.1 mm) I. matches escutcheon. Maximum available, order the diameter dry pendent sprinkler 3-1/16' I 1' (25.4 ruin) longer (77.8 mm) than the 'A' dimension. Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler October 25, 2010 Sprinkler 105e VIKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Base SIN S le Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 Part No.' tyle NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 08383U VK176 Adjustable Standard 1 5.6 80.6 1/2 12.7 Al 16457U -- 25 mm -- 80.6 1/2" 12.7 Al 08385U VK180 Adjustable Recessed 1" 5.6 80.6 1/4" 6.35 B2 16453U -- 25 mm -- 80.6 1/4" 6.35 B2 08387U 1" -- 5.6 80.6 1/2" 12.7 A3 16455U VK172 Plain Barrel -- 25 mm -- 80.6 1/2" 12.7 A3 Approved Temperature Ratings Approved Finishes and "A" Dimensions A- 155°F(68°C), 175°F (79°C), 200°F(93°C), 1 - Brass, Chrome-Enloy1', or White Polyester sprinkler with a Brass, Chrome-Enloy"' or White and 286°F(141 °C) Polyester Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) 2-Brass.Chrome-Enloyy',or White Polyester with"A'dimensions 3-1/4'.to 47-1/2"(82.5 mm to 1,207 mm) B-155°F(68°C), 175°F(79°C),and 200°F(93°C) 3-Brass,Chrome-Enloy5. or White Polyester with "A"dimensions 3"to 47"(76.2 mm to 1,194 mm) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 'K-Factor applies for standard lengths("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. `This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nibco Model 5012-S-Bl tees.When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Reauirements; The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(includ- ing 2-0)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements. hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F 091699 -Care and Handling of Sprinklers.Also refer to page DRY1-3 for general care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other simi- lar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. 1110114M111? V DuI ,. Iioh• For 'A'' Dimension i1. Determine the distance I from face of tee to 1-For 'A` Dimension the finished ceiling. A 2. Round to nearest 1/4' A 1. Determine the (6.35 mm) between distance from Minimum telling openingOutside the face of the 2-1/8' (54 mm) diameter. 3-1/4' (82.5 mm) and dlnmeter, \ tee to the base 47-1/2' (1,207 mm). 1-5/16' 1k of the sprinkler. Maximum ceiling opening: (33.4 mm) 2-1/2' <63.5 mm) diameter. NOTE, Sprinkler will be 2. Round up to the recessed approximately (same as next highest 1/2' • (7.9 mm) above 1' (25 mm) (12.7 mm) incre- 5/16' Schedule ment between 3' the finished ceiling with 40 pipe). (76.2 mm) and Ad justment, 5/8' (15.8 mm) vertical T 47' (1,194 mm). 5/16' (7.9 mm) �_- ll U .-:.:: :.. adjustment available. �•i malt:`:. 5/16' (7.9 mm) I. C--` - Finished ceiling 1-5/8' Minimum 1' (25.4 mm) ;1 (48.3 mm) Maximum 1-5/8' (42.1 mm) ( L._3-1/16' (77.9 mm)-- - it Figure 4: Adjustable Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler Page 1 of 6 ® MICROFAST® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfasts Quick Response Pendent Sprinkler VK302 is a small n thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester, Polytetrafluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) 2. LISTINGS AND APPROVALS cOus cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS VdS Approved: Certificates G414009 and G414010 LPCB Approved LPC$', C E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Viking Technical Data may be found on Rated to 175 psi (12 bar)water working pressure The Viking Corporation's Web site at Factory tested hydrostatically to 500 psi (34.5 bar) http:/Iwww.vikinggroupinc.com. Thread size: 1/2" NPT, 15 mm BSP The Web site may include a more recent Nominal K-Factor: 5.6 U.S. (80.6 metric**) edition of this Technical Data Page. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers; Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, Black PTFE = N, and ENT=JN Temperature Suffix: 135 °F (68 °C) =A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Form No. F_033314 Rev 14.2 (Added 06662B and 18021) Page 3 of 6 II(11S1c ® MICROFAST® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. For ENT coated automatic sprinklers,the waterway is coated III , III Sprinkler wrench 16036W/B"" 1 ## for recessed pendent , sprinklers 0 **A 1/2" ratchet is required (not available from Viking) *410-- Carefully slide the wrench sideways around *"1111.- the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers Form No. F_033314 Rev 14.2 Page 5 of 6 II(IF1G® MICROFAST® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' SIN Number Style NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 NOTICE- Product Below-Limited Availability(Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y,D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A- 135°F(57°C), 155°F(68°C), 175°F(79°C),200 °F Viking Micromatict Model E-1 Recessed (93°C),286°F(141 °C) Approved Finishes Escutcheon B - 135 °F (57°C), 155 °F (68 °C), 175 °F (79 °C), and 1-Brass,Chrome,White Polyester', Y - Standard surface-mounted escutcheon or the 200°F(93°C) and Black Polyester' Viking Microfastt Model F-1 Adjustable Escutcheon. C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2- ENT' or recessed with the Viking Micromatic&Model E-1 °F(141 °C) or E-2 Recessed Escutcheon D- 155°F(68°C), 175°F(79°C),200 °F(93°C) Z - Standard surface-mounted escutcheon or the Viking Microfastt Model F-1 Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. "Other colors are available on request with the same Approvals as the standard colors. ` FM approved as corrosion resistant. FM Aooroval Requirements; The Viking Microfast®Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 14.2 Page 1 of 4 IKIlsIG® MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfast Quick Response Upright Sprinkler VK300 is a small, , • thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in 0 111 decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cOus cULus Listed: Category VNIV FM FM Approved: Classes 2002 and 2020 Refer to Approval Chart 1 and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Viking Technical Data may be found on Deflector: Brass UNS-C23000 or Copper UNS-C19500 The Viking Corporation's Web site at Bulb: Glass, nominal 3 mm diameter http://www.vikinggroupinc.com. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Web site may include a more recent PTFE Tape Screw: Brass UNS-C36000 edition of this Technical Data Page. Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS- S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers. Belleville Spring-Exposed, Screw and Pipcap- ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfase Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, and ENT= JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B.Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 Rev 14.2 (Added 06661B) Page 3 of 4 II(JIs13® MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Base Part SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals' Number' NPT BSP U.S. metric' Inches mm cULus VdS LPCB (E 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 -- -- -- NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 06661B VK300 1/2" 15 mm 8.0 115.2 2-3/16 56 Al, B2 — -- -- Approved Temperature Ratings A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and Approved Finishes 286°F(141°C) - Bras hrome, White Polyester", and Black Polyester" B - 155°F (68 °C), 175°F(79 °C), 200 °F(93°C), and 286 °F (141°C) 2 - ENT6 Footnotes 'Base part number is shown.For complete part number,refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.Wien pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 'Listed by Underwriters Laboratories Inc.for us in the U.S.and Canada 5 Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. cULus Listing Requirements; The Viking Microfasta Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 14.2 Page 1 of 6 N1KING MICROFAST®QUICK TECHNICAL DATA RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is a small thermosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are de- sired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. 2. LISTINGS AND APPROVALS cOus cULus Listed: Category VNIV <> FM Approved: Class 2020 Refer to Approval Chart 1 and Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar.When pressure Viking Technical Data may be found on is measured in kPa,divide the metric K-factor shown by 10.0. The Viking Corporation's Web site at Overall Length: 2-3/4" (68 mm) http://www.vikinggroupinc.com. Material Standards: The Web site may include a more recent Frame Casting: Brass UNS-C84400 or QM Brass edition of this Technical Data Page. Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers; Belleville Spring - Exposed, Screw and Pip cap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast®Quick Response Horizontal Sidewall Sprinkler VK305 by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome= F, White Polyester= M-/W, Black Polyester= M-/B, and ENT= JN Temperature Suffix: 135 °F/57 °C =A, 155 °F/68 °C = B, 175 °F/79 °C = D, 200 °F/93 °C = E, and 286 °F/ 141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F/68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for recessed and/or wax coated sprinklers: Part No. 13655W/B" (available since 2006) **A'1/4"ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) Form No. F_060914 16.01.28 Rev 16.1 Replaces form F_060914 Rev. 14.2 (Revised temperature suffix designation) Page 3 of 6 NII<ING MICROFAST® QUICK TECHNICAL DATA RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 'Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, and ENT coatings. i` Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. i �, —Ow_ Sprinkler wrench 13655W/B** , must be used for installing wax coated sprinklers. **A 1/2" ratchet is required Step 2: Carefully press the wrench onto the (not available from Viking) sprinkler wrench flats. Figure 2: Wrench 13655W/B for Recessed Sprinklers Form No. F_060914 16.01.28 Rev 16.1 Page 5 of 6 NII<ING MICROFAST® QUICK TECHNICAL DATA RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals" Number' NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 12997 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 12121 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X Approved Temperature Ratings Approved Escutcheons A- 135°F(57°C), 155°F(68°C), 175 X - Installed with standard surface-mounted escutcheons or the Viking °F (79°C), 200 °F(93°C), and 286 Approved Finishes Microfast3 Model F-1 Adjustable Escutcheon, or recessed with the °F(141 °C) 1 -Brass Viking Micromatic3 Model E-1, E-2, E-3, or G-1 Recessed Escutcheon B- 135 °F (57°C), 155 °F (68 °C), 175 Y - Installed with standard surface-mounted escutcheons or the Viking °F(79°C), and 200 °F(93°C) Microfast3 Model F-1 Adjustable Escutcheon Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing. Other approvals may be in process. °Viking vertical sidewall sprinklers may be installed pendent or upright. I FM Aooroval Reauirements: Horizontal Sidewall Sprinkler VK305 is FM Approved as a quick response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes,ordinances, and standards, whenever applicable. Form No. F_060914 16.01.28 Rev 16.1 August 14, 2013 Sprinkler 126a NIIKING® INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. PRODUCT DESCRIPTION Viking Institutional Style Quick Response Standard Coverage/Extended Coverage Flush Pendent Sprinklers are small, flush, solder link and lever sprinklers made with tamper-resistant construction. Viking institutional sprinklers have been spe- cifically designed for use with concealed piping in institutional mental health oc- cupancies, correctional facilities, or anywhere a likelihood of tampering with fire sprinklers by the occupants may exist. The institutional sprinkler assembly consists of the sprinkler body, lockring, and a 3-1/4"(82.6 mm) diameter thread-on escutcheon plate. The sprinkler and escutch- fhl i�iil fl1 eon plate have a polished chrome finish. Tests simulating conditions of misuse demonstrate the fusible element assembly — consistently breaks away when connected to a 30 lb. (13.6 kg) weight dropped 6" (152 mm)t. — _ — t For a copy of the break-a-way test described, contact The Viking Corporation. The Viking Corporation disclaims any responsibility for damages or injury (including death) caused by the operation or inoperation of sprinklers arising out of the misuse of or tampering with Viking` brand sprinklers including,without limitation,any personal injury or death arising out of or caused by the manipulation of,dismantling of,or attempted use of the sprinkler or any component as an instrument unrelated to its intended use. 2. LISTINGS AND APPROVALS eO„ cULus Listed: Category VNIV NYC Approved: MEA 89-92-E, Volume 16 cULus Listed as Quick Response Flush Pendent Sprinkler for standard areas of coverage in Light or Ordinary Hazard oc- cupancies. Also cULus Listed for extended areas of coverage up to 16'x 16' (4.9 m x 4.9 m) in Light Hazard occupancies only. Refer to the Approval Chart on page 126c and Design Criteria on page 126d for cULus Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Maximum Working Pressure: 175 psi (12 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) *Metric K-factor measurement is shown in Bar,When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Overall Length: 2-9/32" (57.9 mm) Material Standards: Sprinkler Body: Brass Casting UNS-C84400 Body Cap: Stainless Steel UNS-S30400 or UNS-S30500 Viking Technical Data may be found on Deflector: Copper UNS-C19500 The Viking Corporation's Web site at Deflector Pins: Stainless Steel UNS-S30300 http://www.vikinggroupinc.com. Button: UNS-C23000 H55-H80 The Web site may include a more recent Compression Screw: Brass UNS-C36000 edition of this Technical Data Page. Fusible Link Assembly: Beryllium Nickel and Eutectic Solder Fusible Link Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Escutcheon Materials: Escutcheon Plate: Brass UNS-C26000 Lockring: Stainless Steel UNS-S41000 Available Finishes And Temperature Ratings: Refer to Table 1. Ordering Instructions: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 10554 Form No. F_100998 Revised page replaces page 126a-d dated December 1, 2006. (Added US Patent Number.) August 14, 2013 Sprinkler 126c NIIKING® INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Base NPT Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Part Number' Inches mm U.S. metric2 Inches mm (Refer also to Design Criteria on page 126d.) 10554 1/2 15 5.6 80.6 2-9/32 57.9 cULus° FM NYCE VdS LPCB CE et Standard Coverage Applications- For Light and Ordinary Hazard Occupancies Al -- B1 -- -- __ _- Extended Coverage Applications- For Light Hazard Occupancies Only cULus5 FM NYC VdS LPCB C E e Maximum Area of Coverage: 16'x 16'(4.9 m x 4.9 m) See Minimum Water Supply Requirements: 26 gpm @ 21.6 psi (98.4 L/min @ 1.49 bar) Al -- Footnote 7 -- -- -- -- Approved Temperature Ratings Approved Finish A- 165°F (74 °C) and 220 °F (104°C) B 165°F(74°C) 1 - Polished Chrome Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. ' Listed by Underwriter's Laboratories for use in the U.S. and Canada as a Quick Response Flush Pendent Sprinkler for standard areas of coverage. t Listed by Underwriter's Laboratories for use in the U.S. and Canada as a Quick Response Extended Coverage Flush Pendent Sprinkler for Light Hazard occupancies only. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 16. 'Meets New York City requirements, effective July 1,2008. 1 14//% i MiIE OA 1 1 MI _ 2-3/4" (70 r1r)) Outside Diameter Figure 1: Sprinkler Body, Lockring,and Escutcheon Plate Figure 2: Retaining Flange August 14, 2013 Sprinkler 126e NIKINGI® INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com r2 s YY/ ---------I I- T, LJ-\ i-LJ 1' Nipple rl Li LT TJ I Retaining Flange 1' x 1/2' , to Prevent Reducer Sprinkler Movement r 1 Mei 2-1/4' (57,2 mm) Dia, //, 1 / Opening In Ceiling ‘ L f Mil IN 2' (50 mm) 1/4' (6.4 mm) Adjustment 3-1/4' Dia. (82.6 mm) 3/16' (4.8 mm) ,j NOTE: Upon sprinkler activation, the deflector descends approximately 1/4' (6.4 mm) below the sprinkler body. Figure 3: Sprinkler Dimensions and Installation Adjustment F.After installation, the entire system must be tested in accordance with recognized installation standards. The test is applied after sprinkler installation to ensure that no damage has occurred to the sprinkler during shipping and installation, and to make sure the unit has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint compound or tape applied,and then reinstalled.This is due to the fact that when the joint seal leaks,the sealing compound or tape is washed out of the joint. G.After testing, repairing all leaks, and installing and painting the ceiling, remove the plastic protective shell from the sprinkler. INSTALLATION TIP:Do NOT install the lockring onto the sprinkler until afterthe sprinkler nipple has been cut back to ensure the sprinkler is at the desired elevation in relation to the face of the ceiling.The lockring will prove difficult to remove from the sprinkler once it has been installed above the plane of the ceiling.Check final installation by temporarily installing the escutcheon plate onto the sprinkler withoutthe lockring,using Institutional Escutcheon Installation Wrench 1 0551W/B.If necessary,re-cutthesprinklernippleas required. Once satisfied with sprinkler level compared to the surface of the ceiling, install lockring and escutcheon plate following the steps below. The escutcheon plate cannot be removed after it has been installed with the lockring, so do not install the escutcheon plate with the lockring until after the system has been tested. H.As shown in Figure 4-C and D,fit the lockring over the open end of the protective sprinkler shell and use the shell to gently press the lockring over the threads of the sprinkler. The ring must rest against the two wrench ears of the sprinkler body with the four arms of the lockring pointing outward. I. REMOVE THE PLASTIC PROTECTIVE SHELL from the sprinkler. (Recommendation: retain a protective shell in the spare sprinkler cabinet.) August 14, 2013 Sprinkler 126g INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com The sprinkler pipe above the ceiling leading to the sprinkler must be secured to prevent any movement of the sprinkler. One method of anchoring the pipe above the ceiling is to use the retaining flange and screw assembly that are available from Viking. The flange slides over the sprinkler drop nipple prior to threading the nipple into the branch line tee (see Figure 4-A). 6. INSPECTIONS, TESTS AND MAINTENANCE (Refer to Figures 1-4.) NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For mini- mum maintenance and inspection requirements, refer to NFPA 25 for Inspection, Testing and Maintenance requirements. In addi- tion, the Authority Having Jurisdiction may have additional maintenance requirements that must be followed. A. The sprinklers must be inspected on a regular basis for corrosion, mechanical damage, obstructions, paint, etc. The frequency of inspections may vary due to corrosive atmospheres, water supplies, and activity around the device. B. Sprinklers that have been painted or mechanically damaged must be replaced immediately. Sprinklers showing signs of corro- sion shall be tested and/or replaced immediately as required. Installation standards require sprinklers to be tested and, if neces- sary, replaced after a specified term of service. Refer to the installation standards and the Authority Having Jurisdiction for the specified period of time after which testing and/or replacement is required. Sprinklers that have operated cannot be reassembled or reused, but must be replaced. When replacing sprinklers, use only new sprinklers. C. The sprinkler discharge pattern is critical for proper fire protection. Nothing should be hung from the sprinkler, attached to it, or otherwise obstruct the discharge pattern. All obstructions must be immediately removed or, if necessary, additional sprinklers installed. D. When replacing existing sprinklers,the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. DISASSEMBLY: There are two methods of sprinkler disassembly. In Method 1, the escutcheon plate and lockring are removed first,and then the remaining sprinkler components can be removed without being destroyed.The second method of disassembly results in complete destruction of the unit. Disassembly Method 1: 1. Remove the system from service, drain all water, and relieve all pressure on the piping. NOTE: Disassembly Method 1 results in damage to the 2. Use a drill (not available from Viking) sized appropriately for escutcheon plate and lockring,and they cannot be reused. use with a spanner wrench (see step 3) to make two holes through two opposite indentations on the face of the escutch- eon plate. 3. Use a 2-1/2" C-C spanner wrench (Viking Part No. 10729) to unthread the escutcheon plate by turning it counterclockwise. Make sure that the sprinkler body does not turn or loosen. 4. Remove the lockring from the sprinkler body. 5. Place a protective sprinkler shell (from the spare sprinkler cabinet) over the sprinkler to be removed. 6. With the protective shell over the sprinkler, place Sprinkler Wrench 08336W/B or 10366W/B over the unit and turn it counter- clockwise to carefully unthread the sprinkler body from the reducing coupling. 7. Install the new unit using the sprinkler wrench. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the appropriate orifice size, temperature rating, and response characteristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. (Stock of spare lockrings and escutcheon plates should be available in the spare sprinkler cabinet in addition to the spare sprinkler heads.) 8. Place the system back in service and secure all valves. Check for and repair all leaks. Disassembly Method 2: NOTE: Disassembly Method 2 results in complete destruction of 1. Remove the system from service, drain all water, and the unit. None of the sprinkler components may be reused. relieve all pressure on the piping. 2. Disassemble and remove the fusible element, and bend the deflector and sealing assembly to expose the waterway of the sprinkler. 3. Insert an easy-out screw extractor (Trade No. 6) into the waterway. Turn the easy-out counterclockwise with a wrench to remove the sprinkler assembly from the reducing coupling. 4. Install the new unit using Sprinkler Wrench 08336W/B or 10366W/B. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the appropriate orifice size, temperature rating, and response characteristics. Page 1 of 3 ® MICROFAST® QUICK TECHNICAL DATA RESPONSE VERTICAL SIDEWALL SPRINKLER VK306 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfasts Quick Response Vertical Sidewall Sprinkler VK306 is a small thermo- sensitive glass bulb spray sprinklers designed for installation in either the upright or pendent position.The VK306 is available with finishes and temperature ratings to meet design require- ments. 2. LISTINGS AND APPROVALS FM FM Approved: Class 2012 — Refer to the Approval Chart and Design Criteria for FM Approval requirements t!K that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) **Metric K-factor measurement shown is in Bar. When pressure is measured in kPa,divide Viking Technical Data may be found on the metric K-factor shown by 10.0. The Viking Corporation's Web site at Material Standards: http://www.vikinggroupinc.com. Frame Casting: Brass UNS-C84400 or QM Brass The Web site may include a more recent Deflector. Brass UNS C23000 edition of this Technical Data Page. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Vertical Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the ap- propriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, and Chrome = F Temperature Suffix: 135 °F (57 °C) =A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, and 286 °F (141 °C) = G For example, sprinkler VK306 with a 1/2" NPT thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12983AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: A. Standard Wrench: Part No. 10896W/B (available since 2000). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Form No. F_060614 Rev 15.1 (Removed Figure 2) Page 3 of 3 NIKING. MICROFAST® QUICK TECHNICAL DATA RESPONSE VERTICAL SIDEWALL SPRINKLER VK306 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Base Part Maximum Thread Size Nominal Overall Length Listings and Approvals' Number' SIN Pressure K-Factor (Refer also to Design Criteria below.) NPT BSP U.S. metric' Inches mm cULus FM'' VdS LPCB C E O Standard Orifice 129834 VK306 175 psi 1/2' 15 mm 5.6 80.6 2-1/4 58 -- A1X — -- -- — NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 06727B4 VK306 175 psi 1/2" 15 mm 5.6 80.6 2-1/4 58 -- A1X -- -- -- -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57°C , 155°F (68 °C , 175°F(79°C ,200°F X-Installed with standard surface-mounted ) ) ) 1 - Brass and Chrome (93°C), and 286°F(141 °C) escutcheons Footnotes I Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Viking vertical sidewall sprinklers may be installed pendent or upright. FM Aooroval Reauirements; Vertical Sidewall Sprinkler VK306 is FM Approved as a Quick response sidewall Non-Storage sprinkler, as indicated in the FM Approval Guide. For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including 2-0)and Technical Advisory Bulletins.FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to,but not limited to:minimum water sup- ply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes,ordinances, and standards, whenever applicable. Form No. F_060614 Rev 15.1 (Removed Figure 2) Page 2 of 6 ® MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage`s Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463- HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504(2-3/4"diameter), Base Part No. 13642 (3-5/16"diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper= E-/B, Painted White= M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 °F (57 °C) UL(139 °F (59 °C) FM and LPCB) =A, 165 °F (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 °F (57°C)temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or B. Head Cabinet Wrench Part No. 14031"" (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ''/z' ratchet(not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 Rev 15.1 Page 4 of 6 NIKING® MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com cULus Listing Reauirements; Mirage/Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Aooroval Reauirements; a)The sprinkler can be installed in a concrete ceiling (massive ceiling)or in a false ceiling made of light materials. b)This sprinkler is deflector fixed type and can be only activated by heat.The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845.These sprinklers can only be installed in LH and OH occupan- cies,except in OH4. NOTES: Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type'Domed-CCP'shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 or QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. \oCUSTOM i Q\, A DO NOT PAINT Q 9� WINGv - Identification of Custom Paint Color, All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample 3-5/16" (84.1 mm)-0—{ (a point dot) of the paint on the 'obe' Figure 1: Identification of Custom Paint Color for Concealed Covers Figure 2: Square Cover Assembly 15394 Form No. F_103005 Rev 15.1 Page 6 of 6 NIKING® MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler _ Wrench Sprinkler -um! o Flat iamet (57.2 nirn) Frame1iIi diameter opening Arms go Is required inthe ceiln , 9 '_I'r1� 11 Sprinkler and g — ���! — _ _ Adapter Assembly aillriiP (Protective Cap is removed for _ ��_` Installation--use II■i., - Wrench 14031)1 ) NEVER Install the sprinkler by applying the Installation Sprinkler wrench across the frame arms. Wrench 1114111111111111 (Part No. _ DO N❑T overtighten, 14047W/Bo Use only the designated Is shown) ;=; sprinkler wrench, Viking Part Number 14047W/B or 14031. **A 1/2' ratchet Is required (not 1 DO NOT apply more than =; available from Viking). 25 ft, lbs. of torque. A leak tight seal should be achieved Step 2: Carefully press the by turning the sprinkler Step 11 Carefully slide the wrench upward and turn slightly clockwise 1 to 1-1/2 turns wrench sideways around to ensure engagement with the beyond finger tight. the deflector and pins. sprinkler wrench flats. Figure 3: Sprinkler Installation and Correct Use of Wrenches 1/2' (15 mm) \ — NPT _ _ __ __ _ 2-9/16' .I.�Ij 2-1/16' — �� y 2-3/16' ■I��I� (65 mm) (52 mm) EP��� (55 mm) Maximum Minimum UMMMMIIMMMMMIMM ..' "r, MIIMMEIMMIMISIMMIMM r. mumMoin rs 2-3/4' (70 mm) or 3-5/16° (84.1 mm) Note: Upon sprinkler activation, the deflector descends to approximately 13/16' (20.6 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 Rev 15.1 (Added CCCF Approval) SIDEWINDERSTM HORIZONTAL MOUNT food lut Driver 1/4" 8018957 4016 SWG 100 1/4 X 1 25 9.38 125 #H4SWNutDriver 1/4" 8019957 300 SWG 200 1/4 X 2 25 10.00 125 1 Sidewinders and r Rod Sammys 3/8 8020957 18 SWG 10 1/4 X 1 25 7.50 125 4V. 3/8" 8021957 19 SWG 20 1/4 X 2 25 8.75 125 Q. 3/8" 8022925 26 SWG 25-380 3/8 X 2-1/2 3/8" 8023925 25 25 12.81 125 10.63 125 SWG 30 1/4 X 3 25 i •teel art#8114910 3/8" 8050957 39 SWD 10 1/4-14 X 1 25 7.50 125 3/8" 8051957 40 SWD15 11414X1-112 25 9.38 125 ii-) ti 3/8" 8052957 41 SWD 20 1/4-14 X 2 25 8.13 125 6 ' Item#101 3/8" 8053957 42 SWD 516 5/16-18 X 1-1/4 25 8.75 125 3/8" 8054957 46 SWDR 1-1/2" 1/4-20 X 1-1/2 25 9.06 125 Q• 3/8" 8055957 43 SWDR 1" 1/4-20 X 1 25 8.75 125 lQ• 3/8" 8056957 44 SWDR 516 5/16-18 X 1-1/4 25 10.31 125 3/8" 8057957 45 SWT 15 12-24 X 1-1/2 25 7.81 125 loncrete 9!r 7- ;,2ao0-.;,; rwc 5/16 X 1-1/2 25 9-38 125 3/8" 8061957 85 SWC 20 5/16 X 1-1/2 25 9.38 125 • Most Items Available in Stainless Steelit NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! NEW! * Use with 3/8" Sammy Swivel Head' ipprovals Part# Item# Model Screw Box Weight Case Descriptions Qty. (per 126) Qty U.S.Patent No. • 17°deflection from vertical 6,443,680 • Accommodates up to (1' 8139957 4702 SH-GST 20 1/4 x 2 25 9.38 125 3-1/2 x 12 pitch roof <i• 8140957 4703 SH-GST 22SS 1/4 x 2 25 9.38 125 , • Also available in stainless steel Q, 8141957 4704 SH-GST 30 1/4 x 3 25 10.94 125 V. 8142957 4705 SH-GST 30SS 1/4 x 3 25 10.94 125 - • Use#14 Nut Driver(black) t 8137957 4700 SH-DSTR 1 1/4-20 x 1 25 9.38 125 gi. 8138957 4701 Stl-DSTR 1-SS 1/4-20 x 1 25 9.38 125 aded Rod Directly Patent Pending SAMMY X-PRESS Steel Screw Box Weight Case t{Tom�'in Gauge Metal • Approvals Ga. Part# Item# Model Descriptions Qty. (per 125) Qty peck&Pullin . - gi. 22-20 8150922 500 XP 20 1/4-20 x 1-1/8 25 10.3 125 v h Sammy X-Press 20 418-16 8153922 503 XP 35 t/4 20 x 25 10.3 125 o Sammy X-Press 35 Uninstall: -__ Sammy X-Press It 8151910 501 XPIT 1 Installation Tool 1 1.02 1 aditantnT (Kit includes:Sleeve,Bit Receiver, Hex Wrench,and 25/64"Drill Bit) REBS TM Installed 8152910 502 XPDB 25/64"Drill Bit 1 0.14 1 aTOLCO www.tolco.com NIBCD Revision 12/15/2008 omponent of State of FI • i. •8 - Rod Stiffener California nia OSHPD Approved Seismic Restraints System ,:::1 Fig. •- Fig. 98 = od Stiffener w/Break-off Bolt Head t F Size Range — Secures • :" thru 7/8" hanger rod -=I Material — Carbon Steel '' � ! FY Function — Secures channel to han.- od for vertical seismic bracing. f •, • ���r � Approvals — Included in our Seismic Res :. is Catalog approved ( , by the State of California Office of Statewide Hea • Planningand i Ii ?' Development (OSHPD). For additional load, spacing a : •lacement i information relating to OSHPD projects. please refer to the c- 0 I ' Soo Seismic Restraint Systems Guidelines FIG. 98 '',- Finish — Electro Galvanized ft- Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number ) li II t jiirNi d I li rills ,., :II \ / = I,l / '' " ,,fir �y FIG. 98B '_ . ' I • . • ' - All Thread Rod Cut to Length Size Range — Secure :" thru 7/8" rod in /�i Dimensions 1" increments l(((�/�/ Rod Max. Rec. Load Lbs. Material — Carbon Steel Size For Service Temp Maximum Temperature — 750°F ��� 650°F Finish — Plain „,��l(((....._ �,..e..„. 3/8 730 1/2 1350 Note — Available in Electro Galvanized and 1�����<(/ 5/8 2160 HDG finish or Stainless Steel materials. �l( �/ 3230 Order By — Figure number, rod diameter, rod "``ill 7/8 4480 length and finish Fig. 100 - All Thread Rod Full Length Size Range — Secures 3/8 thru 11/2" rod in 00)*» 10' lengths \ lMaterial — Carbon Steel ���1'�����)����������� Maximum Temperature — 750°F ���������������Finish — Plain 0111 Note — Available in Flectro-Galvanized and Dimensions •Weights HDG finish tainless Ste;e materials. Max Rec. Load Lbs. Order By — Figure number, rod diameter Rod For Service Temps Approx. and finish Size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 1'/2 13800 510 y ® OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com VSR-F P POTTER VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD FIG. 1 FIG.2 SWITCH TERMINAL OPTIONAL TAMPER SWITCH DO NOT LEAVE COVER OFF FOR CONNECTIONS EXTENDED PERIOD OF TIME CLAMPING PLATE RETARD ADJUSTMENT: / TERMINAL TO CHANGE TIME TURN KNOB (EITHER DIRECTION) 1�(-'� � TIGHTEN NUTS FOR DESIRED TIME DELAY. USE THE MINIMUM `I!^ /l`` ALTERNATELY TO AN AMOUNT OF RETARD NECESSARY TO PREVENT �:c` �'� O EVENTUAL 20FT.-LBS (27 n-m) i� 01" FALSE ALARMS, A "B" SETTING IS USUALLY [ �aS ,�I` � OF TORQUE `-r JkCADEQUATE FOR THIS. FACTORY IS SET TO "B". 1, 11 TO INSTALL, DRILL HOLE AS INDICATED: ('/ G d PIPE SIZE HOLE SIZE \ U 0��`� DWG..921.3 2" to 2 1/2" 1 1/4" +1/8" -1/16" �. MOUNT ON PIPE SO (50mm to 65mm) (33mm ±2mm) �� C�.J ARROW ON SADDLE POINTS IN DIRECTION CAUTION: 3" to 8" 2" ±1/8" OF WATERFLOW An uninsulated section of a (8omm to 200mm) 50mm ±2mm) ROLL PADDLE IN Single conductor should not pip OPPOSITE DIRECTION be looped around the terminal Cover Tamper OF WATERFLOW and serve as two separate (with cover in place) connections. The wire must • r. DIRECTION OF be severed, thereby providing O + WATERFLOW supervision of the connection C N.O. N.C. JJJJ (W1ri') (RED) (BLK) APPROX. RETARD SETTINGS (IN SECS.) in the event that the wire x,,,,.,00,, o A 8 C D E becomes dislodged from under DWG. 7st-30 o 10-25 20-4.0 35-55 50-70 60-90 the terminal. FIG.3 TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG.4 1. The Model VSR-F has two To remove knockouts: Place 2 SETS OF NORMALLY switches, one can be used screwdriver at edge of knockouts, OPEN CONTACTS WATERFLOW ZONE ROLE FROM to operate a central station, CLOSE ON ALARM ON FIRE.PANEL FIRE PANELpnot in the center. proprietary or remote signaling m ® ® Err unit, while the other contact is t� 1 E 1 I IN l k�1�l used to operate a local audible or NM MN — ION MI visual annunciator. i pow � I ^r I® U� ® 2. A condition of LPC Approval of [� MN = ME this product is that the electrical THE N.C.AND N .MARKINGS ON POSITIVE DC entry must be sealed to exclude �, THE SWITCH ARE FOR AN ALARM OR HOT AC ,r 4y' CONDITION. BELL moisture. Ij THE CONTACTS ARE REVERSED NEGATIVE NELTTRAL ACR 3. For supervised circuits see WHEN THE DEVICE IS IN THF. NORMAL CONDITION. UWD0 NI-2 "SWltch Terminal Connections" drawing and caution note DWG. ►761-4 (Fig.1). APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges,trapped air,or short retard times,waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge A}-t+,deluge,or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve,that is usually located at the end of the most remote branch line,should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm(38 Lpm)is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT.#8800001-REV X PAGE 2 OF 2 MFG.#5400761-3/07 P POTTER BELLS e The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. 1 Fig.3 A.C.BELLS 1Q.. WHITE(IN) WHITE(OUP L ]), (250) 8" (200) 6.. Tr4:11)1FRP NEL O OL �,'(ISO) PRECEDING BELL �_'•_ BLACK UNl 111111111.1111 I_ ' BLACK(OLT( CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OLT LEADS AS SHOWN. 2 11/16" (68) DWG,/7764 VOWS: I.WHEN USING AC BELLS.TERMINATE.EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2.E.1,11).01-LINE.RESISTOR IS NOT REQUIRED ON AC BELLS. DWOO 776) Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance ,it, 1- . ,III, III 53/4" 0 _ [1] 3 m 5•. LimiliTo(146) (86) (127) Next Device or End-of-Line Ir Resistor Li_ Le_ 6) 15/8" 3(86) 86) (41) 4 1/4" (108) 7....1 L Installation DWG.776.2 1. The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 2. Remove the gong. '15'7: - 3. Connect wiring(see Fig.3). ).. / 4. Mount bell mechanism to backbox(bell mechanism must be Dmounted with the striker pointing down). 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 5» 6. Test all bells for proper operation and observe that they can BBx-1 1v be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). Failure to install striker down will .revent bell from operating. P P g PRINTED IN USA MFG.#5400776-REV Y PAGE 2 OF 2 5/08 _411111, IMIlis an t ro. — — MI INNIMMI 111111.111,illlialM MN Mr . IIIIIIM 11111 sir ice.— —ice.: V --mm. iiiiiimis — .41IIN.■IIMIIIIMI M M IIIIMIIIII I -- MK...., AIR PRODUCTS OLT Plus Series - Single Phase Tank Mount Fire Protection Air Compressor Electrical Cut Sheet 7 This oilless tank mounted air OLT*. ® compressor is UL1450 listed Series for use in sprinkler systems. Factory Amperage (amps) Minimum Wire Size Based Model Nominal i ! on Run Length (gage) Wired -- Number HP Voltage Voltage FLA Start 25 FT 50 FT 100 FT Up 115 5 35 12 12 12 OL12516ACT 1/6 115 208 2.3 16.1 12 12 12 230 2.5 17.5 12 12 12 115 7.4 51.8 12 12 12 OL25033ACT 1/3 115 208 3.5 24.5 12 12 12 230 3.7 25.9 12 12 12 115 10 70 12 10 8 OL36550ACT 1/2 115 208 4.9 34.3 12 12 12 230 5 35 12 12 12 1 115 11.6 81.2 12 10 6 OL43075ACT 3/4 115 208 5 35 12 12 12 230 5.8 40.6 12 12 12 115 18 T 126 12 8 6 OL615100ACT 1 115 208 7.7 53.9 12 12 12 230 9 63 12 12 12 I 115 16.6 116.2 12 8 6 OL915150ACT 11/2 208-230 208 8.2 57.4 12 12 12 230 8.3 58.1 12 12 12 OL1225200ACT 2 208-230 208 11.6 81.2 12 12 10 230 11 77 12 12 10 Note: Wire sizes are based on maintaining 90% of the nominal voltage at starting amps. Starting amps are assumed to be 6 times the SFA. Warning: Failure to consult with a licensed electrical professional can result in serious personal injury or death. Disconnect all power before servicing. Undersized wire between the motor and the power source will limit the starting and load carrying abilities of the motor causing motor overheating and permanent damage to the motor. Wire sizes listed are recommendations only- consult the National Electric Code (NEC) and any applicable local electrical safety codes. The NEC and GAP recommends a maximum voltage drop of 3%. Install motors and related equipment in accordance with the National Electrical Code (NEC) local electrical safety codes and practices. It is always the electrician's responsibility to determine and install a wire size that ensures motors can start and run well. www.generalairproducts.com 1-800-345-8207 6000 Series ',► Flush Fire Dept. Inlet Connections GUARDIAN FIRE EQUIPMENT. INC.Eq1/4 EQU , Residential Function • Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies 1----‘.,\ .r A • Provides 250 GPM flow (minimum), per 2W inlet -• Features/Components soot , 6014/6015 • Single inlet connections incorporate a straight-thru, non-clappered design with female NPT outlets • Two and three-way inlet connections feature brass bodies (angle 0 • or straight pattern), with integral drop-clapper inlets and female NPT outlets :.1s/so17 • Standard components, all connections: Female hose thread swivel inlets, plugs with chains and identification plate • Cast brass construction*, standard "Optional brass finishes on exposed surfaces,add suffix to model no. l -B Polished;-C Rough Chrome Plated;-D Polished Chrome Plated 6024-6029 Single Inlet Connections Back Outlet Top/Bottom Outlet Model No. 6002 6014 6015 6016 6017 t r_A� t �A__I is_r_ Outlet 1/2" 2/2" 3" 2W 3 I aft El Inlet 1W 2W 2W 2%x" 2W B B Plate 4/2'O.D. 7"O.D. 7"O.D. 7"SQ 7"SQ Identification Plate Letterin,:AUTO SPKR 2W Nipple-11 r Plate 3W Dia. (by others) — .— Swivel Swivel Inlet—- - JlFf O 9- Two and Three-Way Connections -- Plug 3/ Li_ Ili D f Model No. Outlet I Size Clappers I A B IC I 15 6024 Back 4"x 2/2"x 2W 2 11W 7W --- 7W 6025 Bottom 4"x 2A"x 2/2" 2 12W 6W 7/e" 7W 6026 To. 4"x2/2"x2/2" 2 12/u" 6W 7W' 7W 6027 Back 6"x 2W x 2W 2 11W 7W' --- 7W 6028 Bottom 6"x 2W x 2W 2 12/8' 7" 7/2" 7% 6029 To. 6"x 2W x 2W 2 12W 8" 9" 7" 6034 Back 4"x 2W x 2W x 21/2" 3 173% 6W --- 6W 6037 Back 6"x 2W x 2W x 2/z' 3 17W 6/8' --- 6W 6038 Bottom 6"x 2W x 2W x 2/2' 3 17W 7%' 7/e' 6W 6039 To• 6"x 2W x 2W x 2/" 3 17%" 7W 7/u" 6% 6034-6099 Identification Plate Lettering: •AUTO SPKR •AUTO SPKR&STANDPIPE Back Outlet Top/Bottom Outlet •STANDPIPE •DRY STANDPIPE A LIMO- 0 ip pe IP 2W Nipple (by others J�W, ` LI, Plate 3W Dia. Swivel f•Notes Inlet • a 9. Plug 3/ L _1 • Pipe nipples for connecting bodies to swivel inlets by others !I I D • Always specify hose threads and identification plate lettering 23' 1 • Contact Guardian for current approvals and special requirements _ Fire Protection by Computer Design WW Gay Integrated Fire Systems 522 Stockton Street Jacksonville, Florida 32204 904 387 7973 D Prev eht/eh QlM nye �C 6Z416 ExcFP CEAIip Job Name : City of Atlantic Beach Public Safety Sy��t, pt�Nsgss Building : NOrfp Location : Offices System : Wet Contract : FP-208716 Data File : CEILING.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CD N 0)OM O(f) N r- V O CO a N O N O V ao a 7 C U) (13 ^E oE13a) cu_a. c0 c ° EEEE � O comma)a) m O a) U) Un 0 U) co U()cn"0)-. a) , a2 L' -NN OM (o (000020(1) E a) 0 ti co 0 co O D Q O co O 2 Z E (o L C C O O V N 0 ct U C ^ 0 Ua) 00 2 0 O < >, 2 N Z a 0 u) U 0 m LL a 2 . i. I O O c o a r- E 0 0 0 0 O 0 co 000 a) c� ai U (I) N u u) � X03 0 N a) c u) L o O II.! .`-= a- �aL (n U T� (a i0 a o _ c c a) 0 0_0aa 0 �+ (II m C (o to 0 a O 0 cn O)CC CC Ii �t Q '0 i 0 M .0 C (0 (Q�-N N O 0 co:k' v U v _ ,........ N 0 0 0 0 0 D C� o U 1 V- c � .- 0 o o 0 o 0 0 0 00 6 ,Z' Q) CO !�. C0 CO 'V CO N r a 0 a CL W to U) D CL W Pressure / Flow Summary - STANDARD , WW Gay Integrated Fire Systems Page 4 City of Atlantic Beach Public Safety Date 11-12-16 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 51 9.333 5.6 13.11 na 20.27 0.15 59 7.0 52 9.333 5.6 13.89 na 20.87 0.15 80 7.0 53 9.333 5.6 18.97 na 24.39 0.15 84 7.0 54 9.333 5.6 21.99 na 26.26 0.15 84 7.0 55 8.0 5.6 15.68 na 22.18 0.1 197 7.0 56 8.0 5.6 12.74 na 19.98 0.1 162 7.0 57 8.0 5.6 13.31 na 20.43 0.1 204 7.0 58 8.0 5.6 13.27 na 20.4 0.1 204 7.0 59 8.0 5.6 17.24 na 23.26 0.1 175 7.0 60 12.083 13.74 na 61 12.083 19.15 na 62 12.083 22.38 na 70 0.0 28.75 na 71 0.0 28.79 na 72 0.0 28.97 na 57A 0.0 25.04 na 73 0.0 25.66 na 74 0.0 29.06 na 80 0.0 31.36 na 90 12.083 26.12 na 91 12.083 26.15 na 92 0.0 31.49 na 93 12.083 26.91 na TOR 0.0 32.39 na IBR 2.5 32.39 na UG1 -3.0 34.99 na UG2 0.0 45.16 na TEST 2.0 44.39 na 100.0 The maximum velocity is 15.28 and it occurs in the pipe between nodes 60 and 61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams 1MN Gay Integrated Fire Systems Page 6 `City of Atlantic Beach Public Safety Date 11-12-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 61 24.39 1.38 0.0 10.500 19.152 to 120.0 0.0 0.0 0.0 62 65.54 0.3076 0.0 10.500 3.230 Vel= 14.06 62 26.26 1.61 T 8.0 5.792 22.382 to 120.0 0.0 8.000 0.0 90 91.8 0.2708 0.0 13.792 3.735 Vel = 14.47 0.0 91.80 26.117 K Factor= 17.96 70 22.18 1.38 0.0 0.833 28.755 to 120.0 0.0 0.0 0.0 71 22.18 0.0408 0.0 0.833 0.034 Vel = 4.76 71 0.0 1.61 0.0 9.042 28.789 to 120.0 0.0 0.0 0.0 72 22.18 0.0196 0.0 9.042 0.177 Vel = 3.50 72 0.0 2.067 0.0 16.000 28.966 to 120.0 0.0 0.0 0.0 74 22.18 0.0058 0.0 16.000 0.093 Vel = 2.12 0.0 22.18 29.059 K Factor= 4.11 57A 40.42 1.38 0.0 4.917 25.037 to 120.0 0.0 0.0 0.0 73 40.42 0.1259 0.0 4.917 0.619 Vel= 8.67 73 20.40 1.61 3E 12.0 6.917 25.656 to 120.0 T 8.0 20.000 0.0 74 60.82 0.1264 0.0 26.917 3.403 Vel = 9.58 74 22.17 2.067 E 5.0 19.917 29.059 to 120.0 T 10.0 15.000 -5.233 91 82.99 0.0666 0.0 34.917 2.324 Vel= 7.93 0.0 82.99 26.150 K Factor= 16.23 80 23.26 2.067 E 5.0 5.750 31.359 to 120.0 T 10.0 15.000 0.0 92 23.26 0.0064 0.0 20.750 0.132 Vel= 2.22 0.0 23.26 31.491 K Factor= 4.14 90 91.80 4.26 0.0 13.833 26.117 to 120.0 0.0 0.0 0.0 91 91.8 0.0024 0.0 13.833 0.033 Vel = 2.07 91 82.99 4.26 0.0 13.833 26.150 to 120.0 0.0 0.0 5.233 92 174.79 0.0078 0.0 13.833 0.108 Vel = 3.93 92 23.26 4.26 T 26.334 40.004 31.491 to 120.0 0.0 26.334 -5.233 93 198.05 0.0098 0.0 66.338 0.651 Vel = 4.46 93 0.0 6.357 7V 88.014 87.871 26.909 to 120.0 0.0 88.014 5.233 TOR 198.05 0.0014 0.0 175.885 0.247 Vel = 2.00 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 4 Fire Protection by Computer Design WW Gay Integrated Fire Systems 522 Stockton Street Jacksonville, Florida 32204 904 387 7973 ✓o 4$11 otlive0ECO D;,, c7 Ivo 020/5 wittr4„PrioA,s4,0Atss Job Name : City of Atlantic Beach Public Safety Npr Building Fp Location : Existing Attic System : Wet Contract : FP-208716 Data File : EXISTING ATTIC.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 a (o N r- O CO CD CO c��4—OMN d p = C co n3 o2-oaa) c LL.0 c c a)� co 0 � ininp �� co UJ O)0)CJ) c,—NN0coa3 (,00010(/) E a) 0 r--- co 0 co 0 O Q O (I) CO D ± Z E co L c 0 O 'cr. a) O ct 0 C ^ 0 LU (V co 2 O — -0 O < T N = Z ›, .0 V 0 2 m 2 a o ) 0 0 n E 0 0 O O (o co 0Zs Lo�O(0 E co C . N 0 U) N V >..= ,_ M 3 N o u) O o � a en o_ (n it t N--co a co U a s a c D • „ o >, co m ci)@ a a ,I 0 0. c 2 I I p o C �o�—NN 1... >Q UUU _ bib - N te 0O v M N CD •—• O O o O o 0 0 0 0 0 0 0 4-, U 0) 00 N- (0 to V M N .-- U W W U) CO p fY UJ Pressure / Flow Summary - STANDARD WW Gay Integrated Fire Systems City of Atlantic Beach Public Safety Page 4 Date 11-11-16 Node Elevation K-Fact No. Pt Pn Flow Actual Density Area Press Actual Re.. MA 0.0 16.69 na 1 12.0 5.6 2 12.0 5.6 8.64 na 16.47 0.1 3 8.26 na 16.09 82 1 7.0 22.875 5.6 7.0 0.1 83 7.0 4 22.875 5.6 7.48 na 14.82 7.0 22.875 0.1 83 5.6 na 15.31 0.1 83 6 22.875 5.6 7.72 na 15.56 7.0 8.19 0.1 111 7.0 7 22.875 5.6 na 16.03 0.1 111 87 12.0 5.6 8.87 na 16.68 7.0 10.29 0.1 11 7.0 9 15.125 5.6 na 17.97 0.1 91 9 15.1 5 5.6 8.43 na 16.26 7.0 8.8 0.1 73 7.0 12 17.042 5.6 10.06 na 16.61 17.042 na 0.1 90 7.0 11 5.6 10.43 17.76 0.1 111 7.0 13 17.042 5.6 na 18.09 0.1 111 14 17.042 5.6 11.01 na 18.58 7.0 1.84 150.1 111 7.0 16 12.0 5.6 19.61 na 19.27 0.1 11 7.0 12.0 5.6 na 17.36 0.1 91 17 11.292 5.6 10.97 na 18.55 7.0 12.15 0.1 130 7.0 18 11.292 5.6 na 19.52 0.1 83 19 11.292 5.6 12.79 na 20.03 7.0 13.13 0.1 83 7.0 20 11.292 5.6 na 20.29 0.1 111 21 11.292 5.6 13.82 na 20.82 7.0 301 0.0 14.82 na 21.56 0.1 111 7.0 40 0.0 14.14 na 0.1 111 7.0 41 0.0 16.06 na 50 0.0 16.13 na 31 0.0 16.35 na 42 0.0 19.19 na 51 0.0 20.07 na 60 12.083 20.43 na 61 12.083 17.08 na 62 00 17.12 na 63 12.083 22.33 na TOR 0.0 19.42 na IBR 2.5 25.29 na UG1 -3.0 25.69 na UG2 0.0 28.79 na TEST 2.0 41.85 na 41.52 na 100.0 The maximum velocity is 13.21 and it occurs in the pipe between nodes 21 and 51 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems ' City of Atlantic Beach Public Safety Page 6 Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt ..C.. Ref.Pointor Ftng's Pe Pv ******* ****** Qt Pf/Ft Eqv. Ln. Total Pf Notes Pn 13 18.58 2.067 0.0 8.000 11.010 to 120.0 0.0 KFactor= 5.60 14 105.27 0.1034 0'0 0.0 0.0 8.000 0.827 Vel= 10.06 14 19.27 2.067 E 5.0 2.583 11.837 to 120.0 0.0 5.000 7.164 KFactor=5.60 42 124.54 0.1411 0.0 7.583 1.070 Vel= 11.91 0.0 124.54 20.071 15 17.36 1.049 3E 6.0 K Factor= 27.80 6.583 9.611 K Factor= 5.60 to 120.0 50 T 5.0 11.000 4.981 17.36 0.1001 0.0 17.583 1.760 0.0 Vel= 6.44 17.36 16.352 16 18.55 1.049 K Factor= 4.29 to E 2.0 1.542 10.971 K Factor= 5.60 120.0 0.0 2.000 4.981 50 18.55 0.1129 0.0 3.542 0.400 Vel= 6.89 0.0 18.55 16.352 17 55.43 1.61 K Factor= 4.59 to 0.0 6.000 12.154 K Factor= 5.60 120.0 0.0 0.0 0.0 18 55.43 0.1065 0.0 6.000 18 0.639 Vel= 8.74 20.03 2.067 0.0 6.000 12.793 to 120.0 0.0 0.0 K Factor= 5.60 0.0 19 75.46 0.0558 0.0 6.000 0.335 Vel= 7.21 19 20.29 2.067 0.0 8.000 13.128 to 120.0 0.0 0.0 K Factor=5.60 0.0 20 95.75 0.0867 0.0 8.000 0.694 Vel= 9.15 20 20.82 2.067 0.0 8.000 13.822 to 120.0 K Factor= 5.60 21 116.57 0.1248 0�0 0'0 0.0 0.0 8.000 0.998 Vel = 11.15 21 21.56 2.067 E 5.0 0.500 14.820 to 120.0 0.0 5.000 4.674 KFactor=5.60 51 138.13 0.1707 0.0 5.500 0.939 Vel= 13.21 0.0 138.13 20.433 30 32.56 1.38 3E 9.0 21.250 14.140 K Factor= 30.56 to 120.0 0.0 9.000 -9.691 3 32.56 0.0843 0.0 30.250 2.551 Vel= 6.98 0.0 32.56 7.000 K Factor= 12.31 40 34.23 1.38 0.0 0.833 16.057 to 120.0 0.0 0.0 0.0 41 34.23 0.0924 0.0 0.833 0.077 41 16.61 1.61 3E 12.0 0.0 16.134 Vel= 7.34 to 120.0 0.0 12.000 -7.164 11 50.84 0.0908 0.0 12.000 1.089 Vel = 8.01 0.0 50.84 10.059 K Factor= 16.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 t-Inal Calculations - Hazen-Williams WW Gay Integrated Fire Systems City of Atlantic Beach Public Safety Page 8 Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Ref. C, p Pt Pt Point Qt Pf/Ft or Ftng's Pe Pv ,*****x Eqv. Ln. Total Notes ****** Pf Pn 100.00 473.62 Qa = 100.00 41.517 K Factor= 73.51 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 t "-dim* is _ _ _ Fire Protection by Computer Design I WW Gay Integrated Fire Systems 522 Stockton Street Jacksonville, Florida 32204I 904 387 7973 prePennr, DEQ h ;,, Job Name : City of Atlantic Beach Public Safety QN 6 Zr7J� Building QF o�xCEp Location New Attic slat_..rioA._Ns System : Wet AS N�rFO Contract : FP-208716 Data File NEW ATTIC.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CO N- Nt vin N co(fl- CO N �N- c N- d D N (a , E ON-0a) CLL a. C0 CD CD as g..,) g)... ) U) I I , 41) NN 0 C C (6DOOIOU) D co co • O Q (I) CO Z E co L C O 5 • a) 0 0' • Li C U ( Q) co f9 < Z a N 0 m U J- W 2 • o_ " o • o 5 a 0 • • U CD . o (0 • CD 000 °O (i) � en v m ( � ai . . U u).0 z L.. 03 ZL_ � LL t .>;c1_ C m 3 .a 0 0_ = CD U a) al a.c>77 O io �113 a`)) a) d rnU c) I.U)ixix U O O O O O O (1) C7 p ( V C) N O OO O CD O CD CD CD O O co (— (O (0 't M N d ix W U) U) D ix W Pressure / Flow Summary - STANDARD VVV;/Gay Integrated Fire Systems Page 4 City of Atlantic Beach Public Safety Date 11-11-16 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1A 11.0 5.6 11.17 na 18.71 0.1 76 7.0 2A 11.0 5.6 11.22 na 18.75 0.1 76 7.0 3A 11.0 5.6 11.24 na 18.78 0.1 76 7.0 4A 11.0 5.6 11.44 na 18.94 0.1 76 7.0 5A 11.0 5.6 11.82 na 19.25 0.1 76 7.0 6A 11.0 5.6 12.11 na 19.49 0.1 76 7.0 7A 11.0 5.6 13.2 na 20.35 0.1 76 7.0 8 12.042 5.6 11.79 na 19.23 0.1 110 7.0 9 12.042 5.6 11.93 na 19.34 0.1 110 7.0 10 12.042 5.6 12.22 na 19.57 0.1 110 7.0 11A 14.333 5.6 10.07 na 17.77 0.1 110 7.0 12A 16.833 5.6 8.97 na 16.77 0.1 110 7.0 13 17.917 5.6 9.84 na 17.57 0.1 110 7.0 14 17.917 5.6 10.13 na 17.82 0.1 110 7.0 15A 14.333 5.6 10.47 na 18.12 0.1 110 7.0 16A 16.833 5.6 9.33 na 17.11 0.1 110 7.0 17 23.667 5.6 7.74 na 15.58 0.1 110 7.0 18 23.667 5.6 7.98 na 15.82 0.1 110 7.0 19 24.6 5.6 8.46 na 16.28 0.1 83 7.0 20A 14.333 5.6 11.62 na 19.09 0.1 106 7.0 21A 16.833 5.6 10.44 na 18.09 0.1 106 7.0 22 28.125 5.6 7.0 na 14.82 0.1 106 7.0 23 28.125 5.6 7.2 na 15.03 0.1 108 7.0 24 28.125 5.6 7.53 na 15.37 0.1 80 7.0 1 10.292 12.39 na 30 10.292 12.45 na 2 10.292 12.45 na 3 10.292 12.47 na 31 10.292 12.63 na 4 10.292 12.69 na 32 10.292 13.08 na 5 10.292 13.1 na 6 10.292 13.41 na 33 10.292 14.33 na 7 10.292 14.59 na 34 10.292 16.26 na 35 10.292 17.3 na 11 0.0 17.11 na 12 0.0 17.21 na 60 0.0 21.8 na 15 0.0 17.54 na 16 0.0 17.61 na 61 0.0 22.16 na 20 0.0 18.79 na 21 0.0 18.83 na 62 0.0 22.33 na 63 0.0 22.76 na 64 0.0 23.18 na 36 10.292 17.6 na 100 12.083 16.67 na 101 12.083 16.74 na 102 12.083 17.19 na 103 12.083 17.34 na 104 12.083 17.58 na 105 12.083 17.98 na 106 12.083 18.44 na 107 12.083 18.58 na TOR 0.0 24.44 na IBR 2.5 24.71 na UG1 -3.0 28.01 na UG2 0.0 42.58 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems City of Atlantic Beach Public Safety Page 6 Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. ..C.. Point or Ftng's Pe Pv ******* Notes ****** Qt Pf/Ft Eqv. Ln. Total Pf Pn 1A 18.71 1.049 E 2.0 1.000 11.166 to 120.0 T 5.0 7.000 K Factor= 5.60 1 18.71 0.1150 0.307 0.0 8.000 0.920 Vel= 6.95 0.0 18.71 2A12.393 K Factor= 5.31 18.75 1.049 E 2.0 1.000 11.215 to 120.0 T 5.0 7.000 K Factor= 5.60 2 18.75 0.1155 0.307 0.0 8.000 0.924 Vel= 6.96 0.0 18.75 12.446 3A 18.78 1.049 K Factor= 5.31 to E 2.0 1.000 11.241 K Factor= 5.60 120.0 T 5.0 7.000 0.307 3 18.78 0.1158 0.0 8.000 0.926 0.0 Vel= 6.97 18.78 12.474 K Factor= 5.32 4A 18.94 1.049 E 2.0 1.000 11.440 K Factor= 5.60 to 120.0 T 5.0 7.000 0.307 4 18.94 0.1176 0.0 8.000 0.941 0.0 Vel= 7.03 18.94 12.688 5A 19.25 1.049 E 2.0 K Factor= 5.32 1.000 11.819 K Factor= 5.60 to 120.0 T 5.0 7.000 0.307 5 19.25 0.1212 0.0 8.000 0.970 0.0 VeI= 7.15 19.25 13.096 6A 19.49 1.049 E 2.0 K Factor= 5.32 to 1.000 12.109 K Factor= 5.60 120.0 T 5.0 7.000 0.307 6 19.49 0.1239 0.0 8.000 0.991 Vel= 7.24 0.0 19.49 13.407 7A 20.35 1.049 E 2.0 1.000 13.204 K Factor= .65.02 K Factor= 5.6 to 120.0 T 5.0 7.000 0.307 0 7 20.35 0.1342 0.0 8.000 1.074 Vel= 7.55 0.0 20.35 14.585 K Factor= 5.33 8 40.04 2.067 0.0 8.000 11.792 to 120.0K Factor= 5.60 9 40.04 0.0174 0.0 0.0 0.0 0.0 8.000 0.139 Vel = 3.83 9 19.34 2.067 0.0 8.000 11.931 to 120.0 K Factor= 5.60 10 59.38 0.0357 0.0 0.0 0.0 0.0 8.000 0.286 Vel = 5.68 10 19.58 2.067 2V 7.0 46.667 12.217 to 120.0 2T 20.0 27.000 -0.018 K Factor= 5.60 100 78.96 0.0607 0.0 73.667 4.471 Vel = 7.55 0.0 78.96 16.670 K Factor= 19.34 11A 17.77 1.049 E 2.0 1.000 10.069 to 120.0 T 5.0 7.000 6.208 K Factor= 5.60 11 17.77 0.1045 0.0 8.000 0.836 Vel = 6.60 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams AM/Gay Integrated Fire Systems Page 8 City of Atlantic Beach Public Safety Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 23 15.03 2.067 0.0 8.000 7.202 K Factor= 5.60 to 120.0 0.0 0.0 0.0 24 64.19 0.0414 0.0 8.000 0.331 Vel = 6.14 24 15.37 2.067 T 10.0 32.500 7.533 K Factor= 5.60 to 120.0 0.0 10.000 12.181 62 79.56 0.0616 0.0 42.500 2.616 Vel = 7.61 0.0 79.56 22.330 K Factor= 16.84 1 18.71 2.067 T 10.0 2.792 12.393 to 120.0 0.0 10.000 0.0 30 18.71 0.0042 0.0 12.792 0.054 Vel = 1.79 30 -20.81 2.067 T 10.0 4.583 12.447 to 120.0 0.0 10.000 0.0 2 -2.1 -0.0001 0.0 14.583 -0.001 Vel= 0.20 2 18.76 2.067 0.0 8.000 12.446 to 120.0 0.0 0.0 0.0 3 16.66 0.0035 0.0 8.000 0.028 Vel = 1.59 3 18.77 2.067 T 10.0 1.417 12.474 to 120.0 0.0 10.000 0.0 31 35.43 0.0138 0.0 11.417 0.157 Vel= 3.39 31 -7.86 2.067 0.0 6.583 12.631 to 120.0 0.0 0.0 0.0 4 27.57 0.0087 0.0 6.583 0.057 Vel = 2.64 4 18.94 2.067 T 10.0 7.083 12.688 to 120.0 0.0 10.000 0.0 32 46.51 0.0228 0.0 17.083 0.390 Vel= 4.45 32 -3.60 2.067 0.0 0.917 13.078 to 120.0 0.0 0.0 0.0 5 42.91 0.0196 0.0 0.917 0.018 Vel = 4.10 5 19.25 2.067 0.0 8.000 13.096 to 120.0 0.0 0.0 0.0 6 62.16 0.0389 0.0 8.000 0.311 Vel = 5.94 6 19.49 2.067 T 10.0 4.333 13.407 to 120.0 0.0 10.000 0.0 i 33 81.65 0.0646 0.0 14.333 0.926 Vel= 7.81 33 2.84 2.067 0.0 3.667 14.333 to 120.0 0.0 0.0 0.0 7 84.49 0.0687 0.0 3.667 0.252 Vel= 8.08 7 20.35 2.067 T 10.0 6.333 14.585 to 120.0 0.0 10.000 0.0 34 104.84 0.1026 0.0 16.333 1.675 Vel = 10.02 34 -38.45 2.067 T 10.0 13.583 16.260 to 120.0 0.0 10.000 0.0 35 66.39 0.0441 0.0 23.583 1.039 Vel= 6.35 35 -32.46 2.067 T 10.0 13.833 17.299 to 120.0 0.0 10.000 0.0 I 36 33.93 0.0127 0.0 23.833 0.303 Vel = 3.24 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems Page 10 City of Atlantic Beach Public Safety Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 34.34 7.000 K Factor= 12.98 62 79.56 3.26 T 20.159 15.708 22.330 to 120.0 0.0 20.159 -5.233 103 79.56 0.0067 0.0 35.867 0.240 Vel= 3.06 0.0 79.56 17.337 K Factor= 19.11 34 38.45 2.067 7V 24.5 82.625 16.260 to 120.0 2T 20.0 44.500 4.457 63 38.45 0.0160 0.0 127.125 2.039 Vel= 3.68 63 0.0 3.26 T 20.159 12.333 22.756 to 120.0 0.0 20.159 -5.233 104 38.45 0.0017 0.0 32.492 0.056 Vel = 1.48 0.0 38.45 17.579 K Factor= 9.17 35 32.46 2.067 7V 24.5 77.000 17.299 to 120.0 2T 20.0 44.500 4.457 64 32.46 0.0117 0.0 121.500 1.424 Vel = 3.10 64 0.0 3.26 T 20.159 6.208 23.180 to 120.0 0.0 20.159 -5.233 105 32.46 0.0013 0.0 26.367 0.033 Vel= 1.25 0.0 32.46 17.980 K Factor= 7.66 36 33.93 2.067 6V 21.0 96.875 17.602 to 120.0 2T 20.0 41.000 -0.776 107 33.93 0.0127 0.0 137.875 1.754 Vel= 3.24 0.0 33.93 18.580 K Factor= 7.87 100 78.96 3.26 0.0 10.292 16.670 to 120.0 0.0 0.0 0.0 101 78.96 0.0066 0.0 10.292 0.068 Vel = 3.04 101 77.79 3.26 0.0 19.167 16.738 to 120.0 0.0 0.0 0.0 102 156.75 0.0235 0.0 19.167 0.450 Vel= 6.03 102 86.50 4.26 0.0 10.333 17.188 to 120.0 0.0 0.0 0.0 103 243.25 0.0144 0.0 10.333 0.149 Vel= 5.48 103 79.56 4.26 0.0 10.000 17.337 to 120.0 0.0 0.0 0.0 104 322.81 0.0242 0.0 10.000 0.242 Vel = 7.27 104 38.45 4.26 0.0 13.417 17.579 to 120.0 0.0 0.0 0.0 105 361.26 0.0299 0.0 13.417 0.401 Vel = 8.13 105 32.45 6.357 V 12.573 42.167 17.980 to 120.0 T 37.72 50.293 0.0 106 393.71 0.0050 0.0 92.460 0.461 Vel= 3.98 106 0.0 6.357 0.0 27.875 18.441 to 120.0 0.0 0.0 0.0 107 393.71 0.0050 0.0 27.875 0.139 Vel = 3.98 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ell . . _ Fire Protection by Computer Design WW Gay Integrated Fire Systems 522 Stockton Street Jacksonville, Florida 32204 904 387 7973 lOck ktie sio Job Name : City of Atlantic Beach Public Safety „`j''e�r�r Building Location : Dispatch Office ���'� e`eh�loh0 System : Pre-action OF osi, �2we Contract : FP-208716 F1, Data File : PREACTION.WXF Sy�� 1( /0 'OA, N°rF0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CD •c- O U)(D LC) N `_ O O Ca f` a)a)w N co M co a_ 0 C (i) (13 3 �— E • 0zt.'.a � LL EL. C c 0 -° E E E E'o� o co 4-0 CVn v)cn"C%> U m � NN OM 00 (0000200) E a) 0 co Q () • O O Q O Cr) (D 2 Z E (0 -C -a C O o a) 0 cc 0 C 0 u-) Q) 0 (6 O < "Z >, • p U W 2 o d • o o a 0 C) • • o • o CO o 0 0 0 (.. . E . . (f) (na� 0 (0 (0 - U m C ac)7-o • o ' • • (n (7)>+ m o ca. cmcA,ra) a) o CI ' o CI) c ca U U N • • • ,� l .1.-...... N ca Q O O co co o O CD 0 O U7 .' M N — 0 0 0 0 0 0 0 0 0 0 0) CO N- (0 M N (.3 d UJ Cl) U) D W Pressure / Flow Summary - STANDARD WW Gay Integrated Fire Systems Page 4 City of Atlantic Beach Public Safety Date 11-12-16 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. P1 8.0 5.6 7.0 na 14.82 0.1 140 7.0 P2 8.0 5.6 7.13 na 14.96 0.1 140 7.0 P3 8.0 5.6 9.77 na 17.5 0.1 140 7.0 P4 8.0 5.6 11.28 na 18.81 0.1 140 7.0 P5 8.0 5.6 11.06 na 18.62 0.1 43 7.0 P10 9.333 7.89 na P11 9.333 10.38 na P12 9.333 12.06 na P13 9.333 12.35 na P14 9.333 16.64 na TPV 15.833 14.34 na BDV 0.0 21.78 na 100 12.083 17.7 na 93 12.083 17.8 na TOR 0.0 23.08 na IBR 2.5 23.02 na UG1 -3.0 25.45 na UG2 0.0 37.43 na TEST 2.0 36.59 na 100.0 The maximum velocity is 13.35 and it occurs in the pipe between nodes P13 and P14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WVV Gay Integrated Fire Systems Page 6 City of Atlantic Beach Public Safety Date 11-12-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 100 84.71 4.26 0.0 48.917 17.701 to 120.0 0.0 0.0 0.0 93 84.71 0.0020 0.0 48.917 0.099 Vel = 1.91 93 0.0 6.357 7V 88.014 87.871 17.800 to 120.0 0.0 88.014 5.233 TOR 84.71 0.0003 0.0 175.885 0.052 Vel= 0.86 0.0 84.71 23.085 K Factor= 17.63 TOR 84.71 6.357 B 12.573 7.000 23.085 to 120.0 S 40.235 52.808 -0.083 ** Fixed Loss = 1 IBR 84.71 0.0003 Fsp 0.0 59.808 0.017 Vel= 0.86 IBR 0.0 4.094 L 6.51 12.000 23.019 to 120.0 0.0 6.510 2.382 UG1 84.71 0.0025 0.0 18.510 0.046 Vel = 2.06 0.0 84.71 25.447 K Factor= 16.79 UG1 84.71 4.07 2F 12.746 91.125 25.447 to 150.0 7L 66.915 82.847 11.691 ** Fixed Loss= 12.99 UG2 84.71 0.0017 G 3.186 173.972 0.294 Vel = 2.09 Zif 0.0 UG2 0.0 5.86 2G 7.668 14.500 37.432 to 150.0 L 11.503 57.513 -0.866 TEST 84.71 0.0003 T 38.342 72.013 0.020 Vel= 1.01 100.00 Qa = 100.00 184.71 36.586 K Factor= 30.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 _ . _ Fire Protection by Computer Design WW Gay Integrated Fire Systems 522 Stockton Street Jacksonville, Florida 32204 904 387 7973 acksont, . kw,min Job Name : City of Atlantic Beach Public Safety Bldg ill Fire r VUBuilding : QV ehtl� Location : High Bay Attic UEC pr D/y System : dry �60 Contract : FP-208716 p OFP Data File HI-BAY DRY.WXF SHF TC#ioxCEns NS qs NOrEn Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 (D 0 N (CDO �L N N��� I,-M CO`_ W0 N C u) fII clid c0 c ° � � � Eo) o co w cn Ci)(I) a) C N N O CO (�D E a) 0 N- co 0 CO C) O Q O (n c Z E L C • ca C] N O • _ C U LU CU CO ca oD < T N = (N Z U 0 - to 0 CO (L ' o - o O E . o U O O .Ca O tL- co • N (n a) . . • CO uw w L >, C Tu Q O O md. a C •' Q t ) o U). O a) r ; �t Cl a) 1 1 1 0 C] c • o CO ANN �.................. ......1 N UU (1)N C) o O o o O o O LU V CO N o O 0 O o O O o O O .- O) CO I,- (D L Cr CO N d CC W U) U) : CC W Pressure / Flow Summary - STANDARD WW Gay Integrated Fire Systems Page 4 City of Atlantic Beach Public Safety Bldg Date 11-11-2016 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. D1 25.375 5.6 7.18 na 15.01 0.1 114 7.0 D2 25.375 5.6 7.24 na 15.07 0.1 64 7.0 D3 25.375 5.6 7.45 na 15.28 0.1 86 7.0 D4 25.375 5.6 8.03 na 15.87 0.1 86 7.0 D5 25.375 5.6 7.75 na 15.59 0.1 86 7.0 D6 25.375 5.6 7.28 na 15.11 0.1 D7 25.375 5.6 86 7.0 D8 7.08 na 14.9 0.1 64 7.0 25.375 5.6 7.03 na 14.84 0.1 114 7.0 D11 29.625 5.6 7.51 na 15.34 0.1 84 7.0 D12 29.625 5.6 7.57 na 15.41 0.1 84 7.0 D13 29.625 5.6 7.8 na 15.64 0.1 84 7.0 D14 29.625 5.6 7.66 na 15.5 0.1 84 7.0 D15 29.625 5.6 7.43 na 15.27 0.1 84 7.0 D16 29.625 5.6 7.37 na 15.2 0.1 84 7.0 D9 25.375 5.6 7.14 na 14.97 0.1 77 7.0 D10 25.375 5.6 7.28 na 15.11 0.1 77 7.0 D19 25.375 5.6 8.13 na 15.96 0.1 114 7.0 D19A 25.375 8.16 na D20 25.375 5.6 8.29 na 16.13 0.1 64 7.0 D21 25.375 5.6 8.53 na 16.35 0.1 86 7.0 D22 25.375 5.6 9.01 na 16.81 0.1 86 7.0 D23 25.375 5.6 8.82 na 16.63 0.1 86 7.0 D24 25.375 5.6 8.35 na 16.18 0.1 86 7.0 D25 25.375 5.6 8.12 na 15.96 0.1 64 7.0 D26A 25.375 7.99 na D26 25.375 5.6 7.95 na 15.79 0.1 114 7.0 D18 25.375 5.6 7.14 na 14.96 0.1 77 7.0 D17 25.375 5.6 7.0 na 14.82 0.1 77 7.0 D40 25.833 9.21 na D42 29.708 8.55 na D44 25.833 9.91 na D41 24.125 10.81 na D43 24.125 12.23 na D45 24.125 12.33 na TDV 0.0 23.51 na BDV 0.0 23.81 na TOR 0.0 24.42 na IBR 2.5 24.65 na UG1 -3.0 27.86 na UG2 0.0 41.84 na TEST 2.0 41.34 na 100.0 The maximum velocity is 11.63 and it occurs in the pipe between nodes D40 and D41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams • WN Gay Integrated Fire Systems Page 6 City of Atlantic Beach Public Safety Bldg Date 11-11-2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 45.97 8.548 K Factor= 15.72 D15 30.47 1.682 0.0 8.000 7.434 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D14 30.47 0.0285 0.0 8.000 0.228 Vel= 4.40 0.0 30.47 7.662 K Factor= 11.01 D16 15.20 1.682 0.0 8.000 7.371 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D15 15.2 0.0079 0.0 8.000 0.063 Vel= 2.19 0.0 15.20 7.434 K Factor= 5.57 D9 14.97 1.38 0.0 6.917 7.143 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D10 14.97 0.0201 0.0 6.917 0.139 Vel= 3.21 D10 15.11 1.38 T 6.0 6.000 7.282 K Factor= 5.60 to 120.0 0.0 6.000 0.0 D19A 30.08 0.0728 0.0 12.000 0.874 Vel = 6.45 0.0 30.08 8.156 K Factor= 10.53 D19 15.96 1.049 0.0 0.333 8.127 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D19A 15.96 0.0871 0.0 0.333 0.029 Vel = 5.92 D19A 30.08 2.067 0.0 6.170 8.156 to 120.0 0.0 0.0 0.0 D20 46.04 0.0224 0.0 6.170 0.138 Vel= 4.40 D20 16.13 2.067 0.0 6.000 8.294 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D21 62.17 0.0390 0.0 6.000 0.234 Vel = 5.94 D21 16.35 2.067 0.0 8.000 8.528 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D22 78.52 0.0600 0.0 8.000 0.480 Vel = 7.51 D22 16.81 2.067 T 10.0 2.750 9.008 K Factor= 5.60 to 120.0 0.0 10.000 -0.198 D44 95.33 0.0860 0.0 12.750 1.097 Vel = 9.11 0.0 95.33 9.907 K Factor= 30.29 D23 94.33 2.067 T 10.0 5.250 8.819 K Factor= 5.60 to 120.0 0.0 10.000 -0.198 D44 94.33 0.0843 0.0 15.250 1.286 Vel = 9.02 0.0 94.33 9.907 K Factor= 29.97 D24 77.70 2.067 0.0 8.000 8.347 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D23 77.7 0.0590 0.0 8.000 0.472 Vel = 7.43 0.0 77.70 8.819 K Factor= 26.16 D25 61.52 2.067 0.0 6.000 8.118 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D24 61.52 0.0382 0.0 6.000 0.229 Vel= 5.88 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems City of Atlantic Beach Public Safety Bldg Page 8 Date 11-11-2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. ..C.. or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BDV 0.0 6.357 4V 50.294 67.042 23.810 to 120.0 0.0 50.294 0.0 TOR 403.71 0.0052 0.0 117.336 0.613 Vel= 4.08 0.0 403.71 24.423 K Factor= 81.69 TOR 403.71 6.357 B 12.573 7.000 24.423 to 120.0 S 40.235 52.808 -0.083 ** Fixed Loss = 1 IBR 403.71 0.0052 Fsp 0.0 59.808 0.312 Vel= 4.08 IBR 0.0 4.094 L 6.51 12.000 24.652 to 120.0 0.0 6.510 2.382 UG1 403.71 0.0446 0.0 18.510 0.825 Vel = 9.84 0.0 403.71 27.859 K Factor= 76.49 UG1 403.71 4.07 2F 12.746 91.125 27.859 to 150.0 7L 66.915 82.847 8.701 ** Fixed Loss = 10 UG2 403.71 0.0303 G 3.186 173.972 5.276 Vel = 9.96 Zif 0.0 UG2 0.0 5.86 2G 7.668 14.500 41.836 to 150.0 L 11.503 57.513 -0.866 TEST 403.71 0.0051 T 38.342 72.013 0.370 Vel= 4.80 100.00 Qa = 100.00 503.71 41.340 K Factor= 78.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 /MAIN . . _ Fire Protection by Computer Design WW Gay Integrated Fire Systems 522 Stockton Street Jacksonville. Florida 32204 904 387 7973 Job Name : City of Atlantic Beach Public Safety Bldg Building : 'locks �� Location : High Bay Dry Pendents opv./e ® System dry D �op�peeve�l/o Contract : FP-208716 Data File : HI-BAY DRY-PENDENTS.WXF �k��per 0 2O/5 h04, H —vs sgsNotFo Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 V r c- N- t` N N-- O ct'O 'c7' N V O cd r-- N Lr) Q O N -a - c m-oa) cUQ cOc •� EEEE � . o con ua) a) a)CDm a') 0)U)ou) m NN Oce) (13 CO0002OO) - E . a) O - co • o () • o . o CD co z E L -a C_ O O a) O U _ C ^ U lU Q) 00 (6 < a 2 .0 U 0 a) 2 o_ ' o CD 5 CD I- C) O CD CO O O O O co (1) Q) (n U cnn � � 3 o Z ma (neo o codW ii a • a U Q 7 7 U a) 03 a.077 o 55 Z/5 CL u ca(13 c c v C j c (0 (II N N O UUU 11� (1) CD O U) V• 00 0 N O O 0 0 0 0 O 0 0 0 UCO0) CO •;:t" r7 N 0_ Q W U) U) O W Ir'ressure / Flow Summary - STANDARD Wl1/Gay Integrated Fire Systems , City of Atlantic Beach Public Safety Bldg Page 4 Date 11-11-16 Node Elevation K-Fact No. Pt Pn Flow Actual Density Area Press Actual Req. 1 23.25 5.6 28.71 23.25 5.6 8.71 na 16.53 0.15 104 23.25 5.6 na 16.53 0.157.0 4 9.05 na 104 7.0 23.25 5.6 16.84 0.15 106 7.0 5 23.25 5.6 9.05 na 16.84 0.15 6 8.8 na 1061 7.0 23.25 5.6 16.62 0.15 110 7.0 68 23.25 5.6 8.68 8.8 na 16.62 0.15 110 23.25na 0.15 7.0 5.6 na 16.5 110 7.0 90 23.25 23.25 5.6 10.477 na 16.5 0.15 1104 7.0 5.618.12 0.15 11 23.25 5 6.6 10.47 na 18.12 0.15 104 7.0 12 23.25 5.6 10.71 na 18.32 104 7.0 13 23.25 5.6 10.71 na 18.32 0.15 106 7.0 14 23.25 5.6 10.68 na 18.3 0.15 1061 7.0 15 23.25 5.6 10.68 na 18.3 0.15 110 7.0 16 10.3 0.15 110 7.0 23.25 5.6 na 17.97 0.15 110 20 24.25 10.3 na 17.97 0.15 7.0 22 24.25 9.35 na 110 7.0 24 24.25 9.72 na 26 24.25 9.45 na 30 24.25 11.36 na 24.25 na 34 24.25 11.56 na 36 24.25 11.53 na 21 25.542 11.38 na 23 25.542 9.34 na 27 25.542 9.73 na 25 25.542 9.35 na 31 25.542 9.44 na 33 25.542 11.39 na 37 25.542 11.67 na 35 25.542 11.46 na 40 0.0 11.64 na 41 0.0 22.58 na 42 24.125 23.88 na TDV 0.0 13.5 na BDV 0.0 24.39 na TOR 0.0 24.54 na IBR 2.5 24.94 na UG1 -3.0 25.02 na UG2 0.0 27.82 na TEST 2.0 39.17 na 38.49 na 250.0 The maximum velocity is 12.71 and it occurs in the pipe between nodes 40 and 41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rural Calculations - Hazen-Williams WA/Gay Integrated Fire Systems City of Atlantic Beach Public Safety Bldg Page 6 Date 11-11-16 Hyd. Qa Dia. Fitting RefRef. ..C.. Pipe Pt Pt . Qt "CI'Pf/ or Ftng's Eqv. Ln. Total Pf Frvi ******* Notes Poin0.0 18.12 11.298 K Factor= 5.39 11 18.32 1.049 to E 2.0 4.667 10.707 120.0 T 5.0 7.000 K Factor= 5.60 32 18.32 0.1107 -0.433 0.0 11.667 1.291 0.0 Vel = 6.80 18.32 11.565 K Factor= 5.39 E 2.0 4.667 10.707 12 18.32 1.049 - 120.0 T 5.0 7.000 K Factor= 5.60 to 32 18.32 0.1107 0.0 11.667 -0. 0.0 1.229191 Vel= 6.80 18.32 11.565 K Factor= 5.39 13 18.30 1.049 to E 2.0 4.667 10.678 120.0 T 5.0 7.000K Factor=5.60 34 18.3 0.1104 0.0 11.667 -0.433 0.0 1.288 Vel = 6.79 18.30 11.533 K Factor= 5.39 14 18.30 1.049 E 2.010.678 to 120.0 4.667 K Factor= 5.60 34 18.3 0.1104 T 5.0 7.000 -0.433 0.0 11.667 1.288 Vel = 6.79 0.0 18.30 11.533 K Factor= 5.39 15 17.97 1.049 to 2E 4.0 5.167 10.300 120.0 T 5.0 9.000 K Factor= 5.60 36 17.97 0.1067 -0.433 0.0 14.167 1.512 Vel= 6.67 0.0 17.97 11.379 K Factor= 5.33 16 17.97 1.049 to 2E 4.0 5.167 10.300 120.0 T 5.0 9.000 K Factor= 5.60 36 17.97 0.1067 -0.433 0.0 14.167 1.512 Vel = 6.67 0.0 17.97 20 33.06 1.38 11.379 K Factor= 5.33 to T 6.0 0.333 9.348 120.0 0.0 6.000 -0.560 21 33.06 0.0868 0.0 6.333 0.0 0.550 Vel = 7.09 33.06 22 33.69 1.38 9.338 K Factor= 10.82 to T 6.0 0.333 9.718 120.0 0.0 6.000 -0.560 23 33.69 0.0898 0.0 6.333 0.569 Vel= 7.23 0.0 33.69 24 33.23 1.38 9.727 K Factor= 10.80 to T 6.0 0.333 9.449 120.0 0.0 6.000 -0.560 25 33.23 0.0876 0.0 6.333 0.555 Vel = 7.13 0.0 33.23 9.444 K Factor= 10.81 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 renal Calculations - Hazen-Williams VVVt/Gay Integrated Fire Systems ,. ' City of Atlantic Beach Public Safety Bldg Page 8 Hyd. Date 11-11-16 Ref. Qa Dia. Fitting Pipe ..C.. Pt Pt Point Qt Pf/Ft Eqv.r Ftng'Ln. Totals Pf PPe � ******* Notes ****** I 72.88 23.879 K Factor= 14.91 37 35.94 2.067 to T 10.0 2.417 11.461 120.0 0.0 10.000 35 35.94 0.0142 0.0 35 0.0 12.417 0.176 36.60 2.067 T 10.0 14.000 Vel= 3.44 to 120.0 11.637 42 72.54 0.0519 0.0 10.000 0.614 0.0 24.000 1.245 0.0 Vel= 6.94 72.54 13.496 K Factor= 19.75 40 132.98 2.067 to 0.0 8.167 22.579 120.0 0.0 0.0 41 132.98 0.1592 0.0 41 0.0 8.167 1.300 Vel= 12.71 72.88 4.26 0.0 6.167 to 120.0 23.879 42 205.86 0.0105 0.0 0.0 -10.448 0.0 6.167 0.065 Vel= 4.63 42 72.55 6.357 8V 100.587 68.750 13.496 to 120.0 0.0 100.587 TDV 278.41 0.0026 10.448 TDV 0.0 169.337 0.445 Vel= 2.81 0.0 6.065 0.0 44.880 24.389 to 120.0 0.0 BDV 278.41 0.0033 0.0 0.0 0.0 44.880 0.148 Vel= 3.09 BDV 0.0 6.357 7V 88.014 67.042 to 120.0 24.537 TOR 278.41 0.0026 0'0 88.014 0.0 0.0 155.056 0.408 Vel= 2.81 0.0 278.41 24.945 K Factor= 55.74 TOR 278.41 6.357 toB 12.573 7.000 24.945 120.0 S 40.235 52.808 -0.083 IBR 278.41 0.0026 Fsp 0.0 59.808 *` Fixed Loss = 1 IBR 0.0 4.094 0.157 Vel= 2.81 to L 6.51 12.000 25.019 120.0 0.0 6.510 2.382 UG1 278.41 0.0224 0.0 18.510 0.415 Vel= 6.79 0.0 278.41 27.816 UG1 278.41 4.07 2F 12.746 91.125 K Factor= 52.79 to 150.0 7L 66.915 82.847 27.701 UG2 278.41 0.0152 8.701 ** Fixed Loss= 10 G 3.186 173.972 2.653 Vel= 6.87 Zif 0.0 UG2 0.0 5.86 2G 7.668 14.500 39.170 to 150.0 L 11.503 57.513 TEST 278.41 0.0026 T 38.342 72.013 -0.866 250.00 0.186 Vel= 3.31 528.41 38.490 Qa = 250.00 K Factor= 85.17 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams \NW Gay Integrated Fire Systems Page 7 City of Atlantic Beach Public Safety Bldg Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *****" Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 26 33.00 1.38 T 6.0 0.333 9.358 to 120.0 0.0 6.000 -0.560 27 33.0 0.0864 0.0 6.333 0.547 Vel = 7.08 0.0 33.00 9.345 K Factor= 10.80 30 36.24 1.38 T 6.0 0.333 11.298 to 120.0 0.0 6.000 -0.560 31 36.24 0.1030 0.0 6.333 0.652 Vel = 7.77 0.0 36.24 11.390 K Factor= 10.74 32 36.65 1.38 T 6.0 0.333 11.565 to 120.0 0.0 6.000 -0.560 33 36.65 0.1050 0.0 6.333 0.665 Vel = 7.86 0.0 36.65 11.670 K Factor= 10.73 34 36.60 1.38 T 6.0 0.333 11.533 to 120.0 0.0 6.000 -0.560 35 36.6 0.1048 0.0 6.333 0.664 Vel = 7.85 0.0 36.60 11.637 K Factor= 10.73 36 35.94 1.38 T 6.0 0.333 11.379 to 120.0 0.0 6.000 -0.560 37 35.94 0.1014 0.0 6.333 0.642 Vel= 7.71 0.0 35.94 11.461 K Factor= 10.62 21 33.06 1.61 0.0 9.500 9.338 to 120.0 0.0 0.0 0.0 23 33.06 0.0409 0.0 9.500 0.389 Vel = 5.21 23 33.69 1.61 0.0 11.917 9.727 to 120.0 0.0 0.0 11.062 40 66.75 0.1502 0.0 11.917 1.790 Vel = 10.52 0.0 66.75 22.579 K Factor= 14.05 27 33.00 1.61 0.0 2.417 9.345 to 120.0 0.0 0.0 0.0 25 33.0 0.0410 0.0 2.417 0.099 Vel= 5.20 25 33.23 1.61 0.0 14.000 9.444 to 120.0 0.0 0.0 11.062 40 66.23 0.1481 0.0 14.000 2.073 Vel = 10.44 0.0 66.23 22.579 K Factor= 13.94 31 36.24 2.067 T 10.0 9.500 11.390 to 120.0 0.0 10.000 0.0 33 36.24 0.0144 0.0 19.500 0.280 Vel= 3.46 33 36.64 2.067 T 10.0 11.917 11.670 to 120.0 0.0 10.000 11.062 41 72.88 0.0523 0.0 21.917 1.147 Vel = 6.97 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems Page 5 City of Atlantic Beach Public Safety Bldg Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 16.53 1.049 E 2.0 4.667 8.714 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 20 16.53 0.0915 0.0 11.667 1.067 Vel= 6.14 0.0 16.53 9.348 K Factor= 5.41 2 16.53 1.049 E 2.0 4.667 8.714 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 20 16.53 0.0915 0.0 11.667 1.067 Vel= 6.14 0.0 16.53 9.348 K Factor= 5.41 3 16.84 1.049 E 2.0 4.667 9.046 K Factor=5.60 to 120.0 T 5.0 7.000 -0.433 22 16.84 0.0947 0.0 11.667 1.105 Vel= 6.25 0.0 16.84 9.718 K Factor= 5.40 4 16.84 1.049 E 2.0 4.667 9.046 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 22 16.84 0.0947 0.0 11.667 1.105 Vel= 6.25 0.0 16.84 9.718 K Factor= 5.40 5 16.62 1.049 E 2.0 4.667 8.805 K Factor=5.60 to 120.0 T 5.0 7.000 -0.433 24 16.62 0.0923 0.0 11.667 1.077 Vel= 6.17 0.0 16.62 9.449 K Factor= 5.41 6 16.62 1.049 E 2.0 4.667 8.805 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 24 16.62 0.0923 0.0 11.667 1.077 Vel = 6.17 0.0 16.62 9.449 K Factor= 5.41 7 16.50 1.049 E 2.0 5.167 8.681 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 26 16.5 0.0912 0.0 12.167 1.110 Vel= 6.13 0.0 16.50 9.358 K Factor= 5.39 8 16.50 1.049 E 2.0 5.167 8.681 K Factor=5.60 to 120.0 T 5.0 7.000 -0.433 26 16.5 0.0912 0.0 12.167 1.110 Vel = 6.13 0.0 16.50 9.358 K Factor= 5.39 9 18.12 1.049 E 2.0 4.667 10.467 K Factor=5.60 to 120.0 T 5.0 7.000 -0.433 30 18.12 0.1083 0.0 11.667 1.264 Vel= 6.73 0.0 18.12 11.298 K Factor= 5.39 10 18.12 1.049 E 2.0 4.667 10.467 K Factor= 5.60 to 120.0 T 5.0 7.000 -0.433 30 18.12 0.1083 0.0 11.667 1.264 Vel = 6.73 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CV CV 0G@ Qg§ 0 c \ @ 0SA c7 k0 T.- V) m Co 0$C �R &o EI CL E .- 0g- m2 COo cr om» �N &0 CV NCV'') 02220 0 022 0»GS0 c0 2 �a �Q $ g2 0 0 < 0 2,- w n0)RR2 CO p ± O a20 CV (0 Z E k Tr 2 - .7 C(0206 / 0 Jowe, r-�$20 C / k \ — ■ c Ce V) r-wn N- 0-1- r § b / // n 22 £ = 0 / { icon .- Tr'-2 ¥ = 03E'Vm e .g o 2 c a) j <-c)43} > ? = f L k CV o(0C §- n.- .- w § O0 2Rc2 i > ° •- 2 2 $ = •5 ƒ = -- >., .0 DoE e / o«�jo�==oj �5 © � m E ® ® _ 0) WI CD a a o co = / - � ƒ � ® 22 % a. onT- aoNw0o2 cQ ■ - m ƒ ƒ & % / I � Imc k = E k ■ CL 0�.- 2oN000U) kU) 2 \ ( s E 2 2 @8 E� 2E£ _ a) C o 2 z « •- '3 2 4 ac.) . - o#o \ 2 % f \ � $ 2 § L i f@ $ o 2oeal ■ E c = I 0 0- ` m ' « r) CO 2 aT-T-�odono� O 02 / EEk CO 712040c -0 cb- e .? E e o c = f � CV° ° ` in E $ mo • ■ ak/ � t aN ¢d 2% E wc2 � % � CO E 0) � k »/$ 5230 2 2w-w E @CL > coe _ mo »o 0. 010 = u) £ E _ cE: >¥ �2# = Q � @ � = o =f a a �� ± _ © 5 ° = o =oin= - o »6o< E ® � 2 2 ) 20 ma « oo�n��r o£ mc » - MS @ = nn� \Q222ƒ � a Qoe ■ - _ EG © << <®«<< <= c ' ) ' �/ � � � 2 \ % 2 § ƒ EE/ƒEUU 111 12 E oaf = c2 ) �t $ 0) > ,z zzz�zzzzo4 � � � gGe7 [ � Cr) ® ® a) • m @ £ = 2 � � a — mu- C o % _( E _ ■ us & - ® � � Q i£ o. ® _ § � @ o �2 /- � / O L< mwu U)I->R = 6 2 & oma ■ a WW Gay Integrated Fire Systems Page 1 City of Atlantic Beach Public Safety Bldg Date 11-11-16 Hydraulic Design Information Sheet Name - City of Atlantic Beach Public Safety Bldg Date - 11-11-16 Location - High Bay Dry Pendents Building - System No. - dry Contractor - WW Gay fire & Integrated Systems Contract No. - FP-208716 Calculated By - Charles Cabbage Drawing No. - FP-1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 23'2.5" Occupancy - Ordinary Hazard Group I S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1950 sqft System Type Sprinkler/Nozzle Density - .15 ( ) Wet Make Viking D Area Per Sprinkler - 130 Max (X) Dry Model VK180 E Elevation at Highest Outlet - 23'2.5" ( ) Deluge Size 1/2" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - N/A ( ) Other Temp.Rat.200 Deg F G Hose Allowance - Outside - 250 gpm dry pendents N Note Actual RA smaller(entire space calculated) Calculation Flow Required - 528.233 Press Required - 38.533 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-26-2016 Cap. - T Time of Test - 2:05 PM Rated Cap.- Elev.- E Static Press - 50 @ Press - R Residual Press - 40 Elev. - Well Flow - 1060 Proof Flow S Elevation - 2 '-0" U P Location - Plaza Rd. Adjacent to Fire Department P L Source of Information - City of Atlantic Beach Fire Rescue Y C Commodity N/A Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled $ Palletized $ Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams . WW Gay Integrated Fire Systems Page 7 City of Atlantic Beach Public Safety Bldg Date 11-11-2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """" Notes "*"'" Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 61.52 8.347 K Factor= 21.29 D26A 45.57 2.067 0.0 5.667 7.993 to 120.0 0.0 0.0 0.0 D25 45.57 0.0221 0.0 5.667 0.125 Vel = 4.36 0.0 45.57 8.118 K Factor= 15.99 D26 15.79 1.049 0.0 0.500 7.951 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D26A 15.79 0.0840 0.0 0.500 0.042 Vel = 5.86 0.0 15.79 7.993 K Factor= 5.59 D18 29.78 1.38 T 6.0 6.000 7.136 K Factor= 5.60 to 120.0 0.0 6.000 0.0 D26A 29.78 0.0714 0.0 12.000 0.857 Vel= 6.39 0.0 29.78 7.993 KFactor= 10.53 D17 14.82 1.38 0.0 6.917 7.000 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D18 14.82 0.0197 0.0 6.917 0.136 Vel= 3.18 0.0 14.82 7.136 K Factor= 5.55 D40 121.68 2.067 E 5.0 1.375 9.211 to 120.0 0.0 5.000 0.740 D41 121.68 0.1351 0.0 6.375 0.861 Vel= 11.63 0.0 121.68 10.812 K Factor= 37.01 D42 92.36 2.067 T 10.0 5.580 8.548 to 120.0 0.0 10.000 2.418 D43 92.36 0.0811 0.0 15.580 1.264 Vel= 8.83 0.0 92.36 12.230 K Factor= 26.41 D44 189.66 2.635 T 16.474 1.375 9.907 to 120.0 0.0 16.474 0.740 D45 189.66 0.0941 0.0 17.849 1.679 Vel= 11.16 0.0 189.66 _ 12.326 K Factor= 54.02 D41 121.68 2.067 0.0 10.500 10.812 to 120.0 0.0 0.0 0.0 D43 121.68 0.1350 0.0 10.500 1.418 Vel= 11.63 D43 92.36 4.26 0.0 8.500 12.230 to 120.0 0.0 0.0 0.0 D45 214.04 0.0113 0.0 8.500 0.096 Vel= 4.82 D45 189.67 6.357 8V 100.587 41.042 12.326 to 120.0 0.0 100.587 10.448 TDV 403.71 0.0052 0.0 141.629 0.741 Vel = 4.08 TDV 0.0 6.065 0.0 44.880 23.515 to 120.0 0.0 0.0 0.0 BDV 403.71 0.0066 0.0 44.880 0.295 Vel = 4.48 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems Page 5 City of Atlantic Beach Public Safety Bldg Date 11-11-2016 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D1 15.01 1.61 0.0 6.000 7.182 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D2 15.01 0.0095 0.0 6.000 0.057 Vel= 2.37 D2 15.06 1.61 0.0 6.000 7.239 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D3 30.07 0.0343 0.0 6.000 0.206 _ Vel= 4.74 D3 15.28 1.61 0.0 8.000 7.445 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D4 45.35 0.0735 0.0 8.000 0.588 Vel = 7.15 D4 15.88 1.61 T 8.0 2.750 8.033 K Factor=5.60 to 120.0 0.0 8.000 -0.198 D40 61.23 0.1280 0.0 10.750 1.376 Vel= 9.65 0.0 61.23 9.211 K Factor= 20.17 D5 60.45 1.61 T 8.0 5.250 7.752 K Factor=5.60 to 120.0 0.0 8.000 -0.198 D40 60A5 0.1251 0.0 13.250 1.657 Vel= 9.53 0.0 60.45 9.211 K Factor= 19.92 _ D6 44.86 1.61 0.0 6.500 7.284 K Factor=5.60 to 120.0 0.0 0.0 0.0 D5 44.86 _ 0.0720 0.0 6.500 0.468 Vel= 7.07 0.0 44.86 7.752 K Factor= 16.11 D7 29.75 1.61 0.0 6.000 7.082 K Factor=5.60 to 120.0 0.0 0.0 0.0 D6 29.75 0.0337 0.0 6.000 0.202 Vel= 4.69 0.0 29.75 7.284 K Factor= 11.02 D8 14.84 1.61 0.0 6.000 7.026 K Factor=5.60 to 120.0 0.0 0.0 0.0 D7 14.84 0.0093 0.0 6.000 0.056 Vel= 2.34 0.0 14.84 7.082 K Factor= 5.58 D11 15.34 1.682 0.0 8.000 7.506 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D12 15.34 0.0079 0.0 8.000 0.063 Vel= 2.21 D12 15.41 1.682 0.0 8.000 7.569 K Factor= 5.60 to 120.0 0.0 0.0 0.0 D13 30.75 0.0290 0.0 8.000 0.232 Vel = 4.44 D13 15.64 1.682 T 9.9 2.750 7.801 K Factor=5.60 to 120.0 0.0 9.900 -0.036 D42 46.39 0.0619 0.0 12.650 0.783 Vel = 6.70 0.0 46.39 8.548 K Factor= 15.87 K Factor=5.60 D14 45.97 1.682 T 9.9 5.250 7.662 to 120.0 0.0 9.900 -0.036 D42 45.97 0.0609 0.0 15.150 0.922 Vel= 6.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 UD 0G2 - §0 \ T.- 0 024 Q / ko , 2I0'N a-R G0 CD gi c CD,- o¥-ccr) R Go S' N-CV p s- oo N &%Q CDaSS0 0 - Sa1.-So CO 220) _Q$GQ 0 0 < CD '-'- N. VI \ ± 10 07210 N(0207( E CO k Nr 2�_ CCD2gCD / 0 a- / 000n .- �,-20 c in: 112 ok .12 \ Ca, a-wn a-ra-a-< E ƒ 7@ / cc 2Uu) ,g VI f2 � o - qN. mn a- Cr UmE- 2 0 G £ cS © a 2 / ) •r= ._ _ ■ ƒ N o ��\-nQa \ / C) / / � f I 7 7 E25 ƒ 2E 2 / o # Nco0NO =O2 �t 222 E mn22 �-n @ CO CO Qt CD co .c 2 / on �oN � co� \ ) / � � � � \ x x as $ = E » e o. 0N� )0N» to02 k� / \ J � � E E 5 ca) E� 2E£ k a) a 2 @ ON 0'- o -oK k 2 E� k0� � 0) 2 O �� 0\ono / L k �C C $ ; 0 til If 1 -le \ 03 20Rc « e kC0 . VC® ® 7e ■ o ■k0 7tok■ _ ■ • // ! }> j\ ) /> cg �k LU \ m - � 0. � fE e � 2 ■I% =S8 022Ea.0 =>i- �2# = G - Q � E _ ©mw2a =:LLt = © t ° = m 7 § 030)C.) §$/ k/ 2q Ta t 13 e � .- nn\QQQQ22 $ In @o ■ C - _ ® 72 e < << <<<< m 207 ' C 2 @ c 2E CLQ_0_ a =Q_a.a_22 E G- o _> � - 03- ,Z u_u.. E k 2 % k � x E2 �/ a) u_� £ / � 222kk ƒ KK E » @ k2ta. 2 .. \ § a o @ o = _ � \ b § k mwu_Io�me >% = 6 _i L 2 wo _ ■ 2 VVW Gay Integrated Fire Systems Page 1 City of Atlantic Beach Public Safety Bldg Date 11-11-2016 Hydraulic Design Information Sheet Name - City of Atlantic Beach Public Safety Bldg Date - 11-11-2016 Location - High Bay Attic Building - System No. - dry Contractor - WW Gay fire & Integrated Systems Contract No. - FP-208716 Calculated By - Charles Cabbage Drawing No. - FP-2 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 30'7.5" Occupancy - Light Hazard Attic S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1950 sqft System Type Sprinkler/Nozzle Density - .1 ( ) Wet Make Viking D Area Per Sprinkler - 130 Max (X) Dry Model VK300 E Elevation at Highest Outlet - 29 '7.5" ( ) Deluge Size 1/2" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - N/A ( ) Other Temp.Rat.200 Deg F G Hose Allowance - Outside - 100 gpm N Note Actual RA smaller(entire space calculated) Calculation Flow Required - 503.76 Press Required - 41.340 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-26-2016 Cap. - T Time of Test - 2:05 PM Rated Cap.- Elev.- E Static Press - 50 @ Press - R Residual Press - 40 Elev. - Well Flow - 1060 Proof Flow S Elevation - 2 '-0" U P Location - Plaza Rd. Adjacent to Fire Department P L Source of Information - City of Atlantic Beach Fire Rescue Y C Commodity N/A Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized 8 Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I Final Calculations - Hazen-Williams . WW Gay Integrated Fire Systems Page 5 City of Atlantic Beach Public Safety Date 11-12-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn P1 14.82 1.049 3E 6.0 8.583 7.000 K Factor= 5.60 to 120.0 T 5.0 11.000 -0.577 P10 14.82 0.0747 0.0 19.583 1.463 Vel= 5.50 0.0 14.82 7.886 K Factor= 5.28 P2 14.96 1.049 3E 6.0 6.500 7.133 K Factor=5.60 to 120.0 T 5.0 11.000 -0.577 P10 14.96 0.0760 0.0 17.500 1.330 Vel= 5.55 0.0 14.96 7.886 K Factor= 5.33 P3 17.50 1.049 2E 4.0 2.667 9.767 K Factor=5.60 to 120.0 T 5.0 9.000 -0.577 P11 17.5 0.1017 0.0 11.667 1.186 Vel= 6.50 0.0 17.50 10.376 K Factor= 5.43 P4 18.81 1.049 2E 4.0 2.667 11.279 K Factor= 5.60 to 120.0 T 5.0 9.000 -0.577 P12 18.81 0.1161 0.0 11.667 1.355 Vel= 6.98 0.0 18.81 12.057 K Factor= 5.42 P5 18.62 1.049 2E 4.0 7.375 11.061 K Factor=5.60 to 120.0 T 5.0 9.000 -0.577 P13 18.62 0.1140 0.0 16.375 1.867 Vel= 6.91 0.0 18.62 12.351 K Factor= 5.30 P10 29.77 1.049 0.0 9.167 7.886 to 120.0 0.0 0.0 0.0 P11 29.77 0.2716 0.0 9.167 2.490 Vel= 11.05 P11 17.50 1.38 0.0 10.000 10.376 to 120.0 0.0 0.0 0.0 P12 47.27 0.1681 0.0 10.000 1.681 Vel= 10.14 P12 18.81 1.61 0.0 2.000 12.057 to 120.0 0.0 0.0 0.0 P13 66.08 0.1470 0.0 2.000 0.294 Vel = 10.41 P13 18.63 1.61 2E 8.0 10.375 12.351 to 120.0 0.0 8.000 0.0 P14 84.71 0.2334 0.0 18.375 4.289 Vel= 13.35 P14 0.0 2.067 V 3.5 3.917 16.640 to 120.0 0.0 3.500 -2.815 TPV 84.71 0.0690 0.0 7.417 0.512 Vel = 8.10 TPV 0.0 2.067 0.0 8.500 14.337 to 120.0 0.0 0.0 6.857 BDV 84.71 0.0692 0.0 8.500 0.588 Vel= 8.10 BDV 0.0 2.067 V 3.5 3.167 21.782 to 120.0 T 10.0 13.500 -5.233 100 84.71 0.0691 0.0 16.667 1.152 Vel= 8.10 0.0 84.71 17.701 K Factor= 20.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 N 0Gq 2U §0 CO 2 0 024 . 7 ko nr- e 2 0$& r-) mo 9k cco CD 0.4-e- WN wo 0G& 0-4 §0 2 NRQ 40/2400 ' $2' LO OD 2ao NtQ$GQ 0 0 % co 2t-N noCR2 0) ± N N(0K in om( E -, c \ Nr e- ,- .7 N(0Rga \ 0 § 00303 -U).0 ` 01=-12 \ n 'wn - rf20 Eu2e / ct 2 � u) tfi d m � 2 £ = 0 5 N0- Wn - _ -2ei =,_ C13 @2cS a, j �0al} > 0..cip ƒ V N o(0CVCC') '— C 6 ? 22cZ i > ° � 7 7 k2 .5 � 2 ) / 0 « CV03004CDco02Z./ 2220 E mm » 777 @ \ j @t co .c - = 2 fon�$CN0- 00Va) k — k24cu .o / CU ƒ & = / 12k � % CL oCV � $oCq10 �oa) k� / = LE). E e a � � E22k£ ƒ - a) o I = « � ' t * o�� Ko-o«o \ q ) @ « ■ /_ � IM Q c ELc m t > / 0 �$ &\ % « a o .- �iL000noit � � / 2 •/ EEk C2c « 5 kam $k / k � J # * m . m . o 2e oq '' \£ 22 § St\_ $ % k � � E a)- >C00a) 11)0\o k / d \ k 2Ja =>e �0g = R � m E / \ ff�±aE:� t = ® o ° = & Sib C moo #bo< � © c > Cl) $ e 2�_ 2ouma)Ip k£ � c ± o Ts @ = nnn�QQ2Q22 Cl) eon@ - E 7 e < << <<«it _ ' ) ' � § � � 0 Cl) k § 2t a. o_ E n ' A ck ( �t $ cn �f fz zzz�zzzz�k / f / \ / LL 6 \ m .92 o EKE ■ � / •- _ a - U 4, as /£ 2 o / g ii_ O LLk cow��o�me>% D 6 2 wom ■2 WW Gay Integrated Fire Systems Page 1 City of Atlantic Beach Public Safety Date 11-12-16 Hydraulic Design Information Sheet Name - City of Atlantic Beach Public Safety Bldg Date - 11-12-2016 Location - Dispatch Office Building - System No. - Pre-action Contractor - WW Gay fire & Integrated Systems Contract No. - FP-208716 Calculated By - Charles Cabbage Drawing No. - FP-1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 8'-0" Occupancy - Light Hazard Office S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 sqft System Type Sprinkler/Nozzle Density - .1 ( ) Wet Make Viking D Area Per Sprinkler - 225 Max (X) Dry Model VK300 E Elevation at Highest Outlet - 8'-0" ( ) Deluge Size 1/2" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - N/A ( ) Other Temp.Rat.200 Deg F G Hose Allowance - Outside - 100 gpm N Note RA reduced for QR sprinklers in ceiling <10 '-0" Calculation Flow Required - 185.705 Press Required - 36.586 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-26-2016 Cap. - T Time of Test - 2:05 PM Rated Cap.- Elev.- E Static Press - 50 @ Press - R Residual Press - 40 Elev. - Well Flow - 1060 Proof Flow S Elevation - 2 '-0" U P Location - Plaza Rd. Adjacent to Fire Department P L Source of Information - City of Atlantic Beach Fire Rescue Y C Commodity N/A Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams • WW Gay Integrated Fire Systems Page 11 . City of Atlantic Beach Public Safety Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 107 33.94 6.357 5V 62.867 45.625 18.580 to 120.0 0.0 62.867 5.233 TOR 427.65 0.0058 0.0 108.92 0.631 Vel = 4.32 0.0 427.65 24.444 K Factor= 86.50 TOR 427.65 6.357 B 12.573 7.000 24.444 to 120.0 S 40.235 52.808 -0.083 ** Fixed Loss= 1 IBR 427.65 0.0058 Fsp 0.0 59.808 0.348 Vel = 4.32 IBR 0.0 4.094 L 6.51 12.000 24.709 to 120.0 0.0 6.510 2.382 UG1 427.65 0.0495 0.0 18.510 0.917 Vel = 10.42 0.0 427.65 28.008 K Factor= 80.81 UG1 427.65 4.07 2F 12.746 91.125 28.008 to 150.0 7L 66.915 82.847 8.701 ** Fixed Loss= 10 UG2 427.65 0.0337 G 3.186 173.972 5.870 Vel = 10.55 Zif 0.0 UG2 0.0 5.86 2G 7.668 14.500 42.579 to 150.0 L 11.503 57.513 -0.866 TEST 427.65 0.0057 T 38.342 72.013 0.411 Vel= 5.09 100.00 Qa= 100.00 527.65 42.124 K Factor= 81.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems Page 9 City of Atlantic Beach Public Safety Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 33.93 17.602 K Factor= 8.09 30 20.81 2.067 3V 10.5 9.500 12.447 to 120.0 0.0 10.500 -0.758 8 20.81 0.0052 0.0 20.000 0.103 Vel = 1.99 0.0 20.81 11.792 K Factor= 6.06 31 7.86 2.067 5V 17.5 11.167 12.631 to 120.0 0.0 17.500 4.457 11 7.86 0.0009 0.0 28.667 0.025 Vel = 0.75 11 17.77 2.067 2V 7.0 6.000 17.113 to 120.0 0.0 7.000 0.0 12 25.63 0.0075 0.0 13.000 0.098 Vel = 2.45 12 16.77 2.067 2V 7.0 13.167 17.211 to 120.0 0.0 7.000 -7.760 13 42.4 0.0192 0.0 20.167 0.388 Vel= 4.05 0.0 42.40 9.839 K Factor= 13.52 60 77.79 3.068 T 15.0 4.667 21.802 to 120.0 0.0 15.000 -5.233 101 77.79 0.0086 0.0 19.667 0.169 Vel = 3.38 0.0 77.79 16.738 K Factor= 19.01 32 3.60 2.067 5V 17.5 10.167 13.078 to 120.0 0.0 17.500 4.457 15 3.6 0.0002 0.0 27.667 0.005 Vel = 0.34 15 18.12 2.067 2V 7.0 6.000 17.540 to 120.0 0.0 7.000 0.0 16 21.72 0.0056 0.0 13.000 0.073 Vel = 2.08 16 17.10 2.067 2V 7.0 15.833 17.613 to 120.0 0.0 7.000 -10.250 17 38.82 0.0163 0.0 22.833 0.372 Vel = 3.71 0.0 38.82 7.735 K Factor= 13.96 61 86.50 3.26 T 20.159 12.708 22.164 to 120.0 0.0 20.159 -5.233 102 86.5 0.0078 0.0 32.867 0.257 Vel= 3.32 0.0 86.50 17.188 K Factor= 20.86 33 -2.84 2.067 5V 17.5 10.167 14.333 to 120.0 0.0 17.500 4.457 20 -2.84 -0.0001 0.0 27.667 -0.003 Vel = 0.27 20 19.09 2.067 2V 7.0 6.000 18.787 to 120.0 0.0 7.000 0.0 21 16.25 0.0032 _ 0.0 13.000 0.042 Vel= 1.55 21 18.09 2.067 2V 7.0 20.042 18.829 to 120.0 0.0 7.000 -12.181 22 34.34 0.0130 0.0 27.042 0.352 Vel= 3.28 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems Page 7 City of Atlantic Beach Public Safety Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 17.77 17.113 K Factor= 4.30 12A 16.77 1.049 E 2.0 3.167 8.966 K Factor=5.60 to 120.0 T 5.0 7.000 7.290 12 16.77 0.0939 0.0 10.167 0.955 Vel= 6.23 0.0 16.77 17.211 K Factor= 4.04 13 59.96 2.067 0.0 8.000 9.839 K Factor=5.60 to 120.0 0.0 0.0 0.0 14 59.96 0.0365 0.0 8.000 0.292 Vel= 5.73 14 17.83 2.067 V 3.5 42.750 10.131 K Factor= 5.60 to 120.0 2T 20.0 23.500 7.760 60 77.79 0.0590 0.0 66.250 3.911 Vel= 7.44 0.0 77.79 21.802 K Factor= 16.66 15A 18.12 1.049 E 2.0 1.000 10.466 K Factor= 5.60 to 120.0 T 5.0 7.000 6.208 15 18.12 0.1082 0.0 8.000 0.866 Vel= 6.73 0.0 18.12 17.540 K Factor= 4.33 16A 17.11 1.049 E 2.0 3.167 9.332 K Factor= 5.60 to 120.0 T 5.0 7.000 7.290 16 17.11 0.0975 0.0 10.167 0.991 Vel= 6.35 0.0 17.11 _ 17.613 K Factor= 4.08 17 54.40 2.067 0.0 8.000 7.735 K Factor= 5.60 to 120.0 0.0 0.0 0.0 18 54.4 0.0305 0.0 8.000 0.244 Vel = 5.20 18 15.82 2.067 2V 7.0 11.042 7.979 K Factor= 5.60 to 120.0 0.0 7.000 -0.404 19 70.22 0.0488 0.0 18.042 0.881 Vel = 6.71 19 16.28 2.067 T 10.0 32.500 8.456 K Factor=5.60 to 120.0 0.0 10.000 10.654 61 86.5 0.0719 0.0 42.500 3.054 Vel= 8.27 0.0 86.50 22.164 K Factor= 18.37 20A 19.09 1.049 E 2.0 1.000 11.624 K Factor=5.60 to 120.0 T 5.0 7.000 6.208 20 19.09 0.1194 0.0 8.000 0.955 Vel= 7.09 0.0 19.09 18.787 K Factor= 4.40 21A 18.09 1.049 E 2.0 3.167 10.440 K Factor=5.60 to 120.0 T 5.0 7.000 7.290 21 18.09 0.1081 0.0 10.167 1.099 Vel = 6.72 0.0 18.09 18.829 K Factor= 4.17 22 49.16 2.067 0.0 8.000 7.000 K Factor=5.60 to 120.0 0.0 0.0 0.0 23 49.16 0.0253 0.0 8.000 0.202 Vel = 4.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard WW Gay Integrated Fire Systems Page 5 City of Atlantic Beach Public Safety Date 11-11-16 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. TEST 2.0 42.12 na 100.0 The maximum velocity is 10.55 and it occurs in the pipe between nodes UG1 and UG2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 c1 OW ag §0 CO \ 01 024 .-7 k0 co .— co e ,- o $& »R \o 9I I c ,_ o¥.- c% Wo OM.- we §o & R» We-WOO 0 MN .- ».GGO = 2$0) .72.7§2 0 0 « OV.. w n0)RR.- @ CO D ± co o2r Nc2m\ Z E o \et 2,-_ NCOR26 / omn <- U).20 C (Li \ § � k n co .- U) a2U § ƒ 7e $ ƒ Oto t% 5 = L 1 / \ mon - � ,- 24 gEE� 2 .2G2c � u a) / ) % :. -weer 2 U . o@LL > ace = L C CU)C §.-n - .- n § % o � ° cf 73i '0 '0 U > ° ' >. . 4) ■ V '= 22 � .0 fo«C]0C0U)02 >,..0O3...01740 E ® - _ &® K � �� / m o f on�\0C � =oj 2 - k / eee / I e e cG ■ • © $ ƒ x . m / I c } e $ u) r- o. ON,- ;oNLOWo $ km 33 � 5m — E 2 2 @ � �� 2Ef / o . § 2 » oN� \c-o _ o & U k 2 ° k � �/ � c E .0 ' 0 � % J2 2 0--§o\onoit ° ono a o@ ■ ° £ � _ � 22 / EEk k2 = c2e � � 5mf $ � f E \ K E7 ® SES I � aS / � § @ -• .0 LN >d 2� § wte - � £ m = - E ® \ --k »// Ef� 3 2 2 $ § E eI >.coem ,o » o o = § u) £ E E _ % a&§>¥ �2# = o « @ D = o . =fw� aE��t � � « zc ; oi. = • o #oo< cU) c22 = m $ Q 3 »_ oo-Jnalp \. mac ' « V @ = nnn nn.-� n oa (5m = — »�� � � _ 0 $ C _ « o a) a)/ a' < <<CO<< << M ' m E oaE ® ,- c 2E = �� » �a�� f� E _ = E/ S �yo D - � a � ������U- b c $ CO > &z zzz� zzzzmk / � / \ \ k / k k � ® ± co C 55 E/ . ED & 22 § 0 . ' § @oe t =� g� � � / O I<I cowu_IC_jme>% = 6 a 2 uomea WW Gay Integrated Fire Systems Page 1 City of Atlantic Beach Public Safety Date 11-11-16 Hydraulic Design Information Sheet Name - City of Atlantic Beach Public Safety Bldg Date - 11-10-2016 Location - New Attic Building - System No. - Wet Contractor - WW Gay fire & Integrated Systems Contract No. - FP-208716 Calculated By - Charles Cabbage Drawing No. - fFP-3 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 29'6" Occupancy - Light Hazard Attic S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1950 sqft System Type Sprinkler/Nozzle Density - .1 ( ) Wet Make Viking D Area Per Sprinkler - 130 Max (X) Dry Model VK300 E Elevation at Highest Outlet - 29'7.5" ( ) Deluge Size 1/2" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - N/A ( ) Other Temp.Rat.200 Deg F G Hose Allowance - Outside - 100 gpm N Note RA increased 30% for roof pitch, no bonus for QR hds due to height Calculation Flow Required - 529.647 Press Required - 42.124 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-26-2016 Cap. - T Time of Test - 2:05 PM Rated Cap.- Elev.- E Static Press - 50 @ Press - R Residual Press - 40 Elev. - Well Flow - 1060 Proof Flow S Elevation - 2 '-0" U P Location - Plaza Rd. Adjacent to Fire Department P L Source of Information - City of Atlantic Beach Fire Rescue Y C Commodity N/A Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 J Final Calculations - Hazen-Williams \MN Gay Integrated Fire Systems Page 7 City of Atlantic Beach Public Safety Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 50 35.91 1.38 0.0 4.708 16.352 to 120.0 0.0 0.0 -4.674 17 35.91 0.1011 0.0 4.708 0.476 Vel= 7.70 0.0 35.91 12.154 K Factor= 10.30 31 110.95 2.067 E 5.0 10.458 19.193 to 120.0 T 10.0 15.000 -5.017 60 110.95 0.1139 0.0 25.458 2.900 Vel = 10.61 0.0 110.95 17.076 K Factor= 26.85 42 124.54 2.067 T 10.0 4.667 20.071 to 120.0 0.0 10.000 -5.017 61 124.54 0.1410 0.0 14.667 2.068 Vel = 11.91 0.0 124.54 17.122 K Factor= 30.10 51 138.13 2.067 T 10.0 1.083 20.433 to 120.0 0.0 10.000 0.0 62 138.13 0.1708 0.0 11.083 1.893 Vel = 13.21 0.0 138.13 22.326 K Factor= 29.23 60 110.95 4.26 0.0 13.833 17.076 to 120.0 0.0 0.0 0.0 61 _ 110.95 0.0033 0.0 13.833 0.046 Vel = 2.50 61 124.54 4.26 0.0 13.833 17.122 to 120.0 0.0 0.0 5.017 62 235.49 0.0135 0.0 13.833 0.187 Vel = 5.30 62 138.13 4.26 T 26.334 40.004 22.326 to 120.0 0.0 26.334 -5.017 63 373.62 0.0318 0.0 66.338 2.110 Vel = 8.41 63 0.0 6.357 5V 62.867 87.871 19.419 to 120.0 T 37.72 100.587 5.017 TOR 373.62 0.0045 0.0 188.458 0.853 Vel = 3.78 0.0 373.62 _ 25.289 K Factor= 74.30 _ TOR 373.62 6.357 B 12.573 7.000 25.289 to 120.0 S 40.235 52.808 0.134 ** Fixed Loss= 1 IBR 3.7.3.62 _0.0045 Fsp 0.0 59.808 0.270 Vel= 3.78 IBR 0.0 4.094 L 6.51 12.000 25.693 to 120.0 0.0 6.510 2.382 UG1 373.62 0.0386 0.0 18.510 0.715 Vel = 9.11 0.0 373.62 28.790 K Factor= 69.63 UG1 373.62 4.07 2F 12.746 91.125 28.790 to 150.0 7L 66.915 82.847 8.484 ** Fixed Loss= 10 UG2 373.62 0.0263 G 3.186 173.972 4.572 Vel = 9.21 Zif 0.0 UG2 0.0 5.86 2G 7.668 14.500 41.846 to 150.0 L 11.503 57.513 -0.650 TEST 373.62 0.0045 T 38.342 72.013 0.321 Vel = 4.44 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems Page 5 City of Atlantic Beach Public Safety Date 11-11-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 16.47 1.049 T 5.0 0.667 8.645 K Factor= 5.60 to 120.0 0.0 5.000 4.981 30 16.47 0.0907 0.0 5.667 0.514 Vel= 6.11 0.0 16.47 _ 14.140 K Factor= 4.38 2 16.09 1.049 T 5.0 5.333 8.260 K Factor= 5.60 to 120.0 0.0 5.000 4.981 30 16.09 0.0870 0.0 10.333 0.899 Vel = 5.97 0.0 16.09 14.140 K Factor= 4.28 3 47.38 1.61 0.0 6.000 7.000 K Factor= 5.60 to 120.0 0.0 0.0 0.0 4 47.38 0.0797 0.0 6.000 0.478 Vel= 7.47 4 15.31 2.067 0.0 6.000 7.478 K Factor= 5.60 to 120.0 0.0 0.0 0.0 5 62.69 0.0397 0.0 6.000 0.238 Vel= 5.99 5 15.55 2.067 0.0 8.000 7.716 K Factor= 5.60 to 120.0 0.0 0.0 0.0 6 78.24 0.0596 0.0 8.000 0.477 Vel = 7.48 6 16.03 2.067 0.0 8.000 8.193 K Factor= 5.60 to 120.0 0.0 0.0 0.0 7 94.27 0.0842 0.0 8.000 0.674 Vel = 9.01 7 16.68 2.067 E 5.0 0.583 8.867 K Factor= 5.60 to 120.0 0.0 5.000 9.691 31 110.95 0.1137 0.0 5.583 0.635 Vel = 10.61 - - 0.0 110.95 19.193 K Factor= 25.33 8 17.97 1.049 E 2.0 5.333 10.294 K Factor= 5.60 to 120.0 0.0 2.000 4.981 40 17.97 0.1066 0.0 7.333 0.782 Vel = 6.67 0.0 17.97 16.057 K Factor= 4.48 9 16.26 1.049 E 2.0 7.583 8.430 K Factor= 5.60 to 120.0 T 5.0 7.000 6.334 40 16.26 0.0887 0.0 14.583 1.293 Vel = 6.04 0.0 16.26 _ 16.057 K Factor= 4.06 10 16.61 1.049 E 2.0 9.500 8.800 K Factor= 5.60 to 120.0 T 5.0 7.000 5.811 41 16.61 0.0923 0.0 16.500 1.523 Vel = 6.17 0.0 16.61 16.134 K Factor= 4.14 11 68.60 2.067 0.0 8.000 10.059 K Factor= 5.60 to 120.0 0.0 0.0 0.0 12 __ 68.6 0.0468 0.0 8.000 0.374 Vel = 6.56 12 18.09 2.067 0.0 8.000 10.433 K Factor= 5.60 to 120.0 0.0 0.0 0.0 13 86.69 0.0721 0.0 8.000 0.577 Vel = 8.29 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C °G@ ag §o 0 \ o 02C Q7 SD M '- co 'RG Q $ - og& o E to 11c a 0- c\ Qo om» N- � p0 2 §RQ C2G0 0 0 o2p 10a2@o 03 220 _ Q $ AQ 0 0 < o s- s- w n0) RRs- n D ± 2 U) � =K(CD 10 0 z E / « NOV ( OCR( / omn a- Oa-a-0 ` wo12 ws § Cc, a-Nn - IO�2CD E $ E § ƒ 2§ Uu) tq 2a � 0 2n / N P,cn # .- ¥ 0 ■ E-0 \ ¥ » » •� E ° k 2 O 2 % ._ _ e � N ���\- M, \ 0 $ / $ / I k k 0.a) k A' o#Nf0CMWOm �5 Eo « o E co © ® » c ., 2 Co o 5 cot ° ■ ® 2 f on��oN �oo� Cu) t § / g2 k ƒ ƒ & m / I ■ % rc = E # 0 o. ON.- §oN1010o § kU) u) -t-.... \ � E 2 2 � � E� 2i£ _c 0 a) t 00- 2 = -4 ma k « ow� Ko�o- ok q 2 w0 $ F2 E . 'E� E B. � � _. - 0 m / ƒ qC $w 0mN—§o\on0l 0. / \C $ 2t --a CU.- f = 6') 2 ® o , E« w $ aS E / / S mm ' mf k_ 7 k �\ \ ©\�/� kc ..c) a" E � ƒ � co50 38 \ § 22mf E ii- .c ƒ22 \277ƒƒ = 5225 � N u)En cu) c2cl = U) $ Q m�# uoumolp \£ m / » 2 em nnn7\ »QQ±\ a EfE <0 ® w/ e <<<®<<<<= _ � £ a ' o n "2 ® c = E (LCL(1 » =�CL . .2 E _ ' E 0)- yo £ ■ Q2 zz)ƒZZZZO) m cg, Q = - X ® 2 #k f Cl) = D2 LL � ƒ 7 / ƒ � G k \ 2 § $ § $ /� � � LL $ O Ik mw� 2o �Uw>§ = 6 a 2 u % mm2 , WW Gay Integrated Fire Systems Page 1 City of Atlantic Beach Public Safety Date 11-11-16 Hydraulic Design Information Sheet Name - City of Atlantic Beach Public Safety Bldg Date - 11-11-2016 Location - Existing Attic Building - System No. - Wet Contractor - WW Gay fire & Integrated Systems Contract No. - FP-208716 Calculated By - Charles Cabbage Drawing No. - FP-2 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 22'-10" Occupancy - Light Hazard Attic S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1950 sqft System Type Sprinkler/Nozzle Density - .1 ( ) Wet Make Viking D E Area Per Sprinkler - 130 Max (X) Dry Model VK300 Elevation at Highest Outlet - 29'7.5" ( ) Deluge Size 1/2" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - N/A ( ) Other Temp.Rat.200 Deg F G Hose Allowance - Outside - 100 gpm Top of truss to Ceiling = 14 '-0" N Note RA increased 30% for roof pitch, 34% reduction for QR sprinklers Calculation Flow Required - 473.615 Press Required - 41.517 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-26-2016 Cap. - 11 T Time of Test - 2:05 PM E Static Press - 50 R Residual Press - 40 Rated Cap.- Elev.- @ Press - Elev. - Well Flow - 1060 Proof Flow S Elevation - 2 -0" U P Location - Plaza Rd. Adjacent to Fire Department P L Source of Information - City of Atlantic Beach Fire Rescue Y C Commodity N/A Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack 11 M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams • , W Gay Integrated Fire Systems Page 7 W City of Atlantic Beach Public Safety Date 11-12-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 198.05 32.389 K Factor= 34.80 TOR 198.05 6.357 B 12.573 7.000 32.389 to 120.0 S 40.235 52.808 -0.083 ** Fixed Loss = 1 IBR 198.05 0.0014 Fsp 0.0 59.808 0.084 Vel = 2.00 IBR 0.0 4.094 L 6.51 12.000 32.390 to 120.0 0.0 6.510 2.382 UG1 198.05 0.0119 0.0 18.510 0.220 Vel = 4.83 0.0 198.05 34.992 K Factor= 33.48 UG1 198.05 4.07 2F 12.746 91.125 34.992 to 150.0 7L 66.915 82.847 8.753 ** Fixed Loss = 10.052 UG2 198.05 0.0081 G 3.186 173.972 1.413 Vel= 4.88 Zif 0.0 UG2 0.0 5.86 2G 7.668 14.500 45.158 to 150.0 L 11.503 57.513 -0.866 TEST 198.05 0.0014 T 38.342 72.013 0.099 Vel= 2.36 100.00 Qa= 100.00 298.05 44.391 K Factor= 44.73 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams WW Gay Integrated Fire Systems Page 5 City of Atlantic Beach Public Safety Date 11-12-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 51 20.27 1.049 E 2.0 11.625 13.108 K Factor= 5.60 to 120.0 0.0 2.000 -1.191 60 20.27 0.1334 0.0 13.625 1.818 Vel= 7.52 0.0 20.27 13.735 K Factor= 5.47 52 20.87 1.049 T 5.0 2.333 13.894 K Factor= 5.60 to 120.0 0.0 5.000 -1.191 60 20.87 0.1407 0.0 7.333 1.032 Vel= 7.75 0.0 20.87 13.735 K Factor= 5.63 53 24.39 1.049 T 5.0 2.333 18.966 K Factor=5.60 to 120.0 0.0 5.000 -1.191 61 24.39 0.1878 0.0 7.333 1.377 Vel= 9.05 0.0 24.39 19.152 K Factor= 5.57 54 26.26 1.049 T 5.0 2.333 21.993 K Factor=5.60 to 120.0 0.0 5.000 -1.191 62 26.26 0.2155 0.0 7.333 1.580 _ Vel = 9.75 0.0 26.26 22.382 K Factor= 5.55 55 22.18 1.049 E 2.0 59.000 15.681 K Factor=5.60 to 120.0 0.0 2.000 3.465 70 22.18 0.1575 0.0 61.000 9.609 Vel = 8.23 0.0 22.18 28.755 K Factor= 4.14 56 19.98 1.049 E 2.0 66.000 12.736 K Factor=5.60 to 120.0 0.0 2.000 3.465 57A 19.98 0.1299 0.0 68.000 8.836 Vel= 7.42 0.0 19.98 25.037 K Factor= 3.99 57 20.43 1.049 T 5.0 56.000 13.313 K Factor=5.60 to 120.0 0.0 5.000 3.465 57A 20.43 0.1354 0.0 61.000 8.259 Vel= 7.58 0.0 20.43 25.037 K Factor= 4.08 58 20.40 1.049 T 5.0 61.083 13.270 K Factor= 5.60 to 120.0 0.0 5.000 3.465 73 20.4 0.1350 0.0 66.083 8.921 Vel = 7.57 0.0 20.40 25.656 K Factor= 4.03 59 23.26 1.049 T 5.0 56.917 17.245 K Factor= 5.60 to 120.0 0.0 5.000 3.465 80 23.26 0.1720 0.0 61.917 10.649 Vel= 8.63 0.0 23.26 31.359 K Factor= 4.15 60 41.15 1.049 0.0 10.958 13.735 to 120.0 0.0 0.0 0.0 61 41.15 0.4943 0.0 10.958 5.417 Vel= 15.28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 % 5 eGq Q$ § o UD / q1 084 cG k0 � n CO 1 01-0$N 00R Go A$ �� 2 DD» 0'— CO k GoCD Nt 012 N-CI § 0 0 CI &\Q CD T- S0 0 2q'- r»GS0 CO .-CD #QgG2 0 010 < o '- '- w naRR'- 0 � 3 0 CD2to N00Rm] Z E \ # '-._ NWNN00 \ / omn '- co».-o ƒ § k/ .1) n -N-n '- toa2U) a) CO E § ƒ m \ k � � � $ \ � CDn ,- _ T-2 = mE� 2 0 » a .ge2 § S ¥ a) o o % : a) 2 C•1 00�\T- nzr-%\ / o 0.k / • 2 i o - 7 a) 0113 •ƒ 22i Al o#�2o�� co mo� a./ E22o E u.) caCD $ » 777 11°- 0) j . cC CD o .c 2 / on��o� � oo� / > / 0 � � � / L ■ a = c $ = E3m E 0N� $oNtU0 ( k� / k % J \ - E �� 2 $ 0e -11'. �CE ƒ £ n2z « a » t@ k ocs, - \o� o _ o0) 0) 7f E� � / 2 § fa = 'a " tea -6 � o - T-§o\ono / ƒ q 7 ,•;:_) • \ / k COC � c25 c 13 ® = - _c $ » E 2 R $ o ■ // J ! 2 u) � • mf k_ CU CO �\ \ ©\ k}� > c " o E > 2 ! � > E .G.-r; e � » e ' 2 E E .-°> -k/2 �2 co 7 / § f � k k\in.ckoca b05, � � � 2 2f m $ o mo« oo�m�Ir � 0a 0 V %f QQQ/QQQQ2� ¢ / / —1c � < 2 ® 2 £ _ E QEE3EEEE§± E - e o� U_\� .- £ e §) LL u_ kc \ k Ek £4- f • � = f = � k / kf ƒ c o % 2¢ . ES 6220..0 � a e £ � 5 =� � = � $ d § k wwU- U-oume>% = B JL a 2 uo � ea ti WW Gay Integrated Fire Systems Page 1 City of Atlantic Beach Public Safety Date 11-12-16 Hydraulic Design Information Sheet Name - City of Atlantic Beach Public Safety Bldg Date - 11-12-2016 Location - Offices Building - System No. - Wet Contractor - WW Gay fire & Integrated Systems Contract No. - FP-208716 Calculated By - Charles Cabbage Drawing No. - FP-1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 9'4" Occupancy - Light Hazard Office (Storage rooms in calc @ .15 density) S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 sqft System Type Sprinkler/Nozzle Density - .1 ( ) Wet Make Viking D Area Per Sprinkler - 225 Max (X) Dry Model VK300 E Elevation at Highest Outlet - 9 '4" ( ) Deluge Size 1/2" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - N/A ( ) Other Temp.Rat.200 Deg F G Hose Allowance - Outside - 100 gpm 48" Flex Drop = 56' of 1" Sch40 N Note RA reduced for QR sprinklers in ceiling <10 '-0" Calculation Flow Required - 298.047 Press Required - 44.391 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-26-2016 Cap. - T Time of Test - 2:05 PM Rated Cap.- Elev.- E Static Press - 50 R Residual Press - 40 @ Press - Elev. - Well Flow - 1060 Proof Flow S Elevation - 2 '-0" U P Location - Plaza Rd. Adjacent to Fire Department P L Source of Information - City of Atlantic Beach Fire Rescue Y C Commodity N/A Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 r 14r IliimE=— —=>•■IIII\ A NM ....r —i•IMIN 111111111111111111 IIIIIIIIIII 11MJIIIII —= A 114kr, AIR PRODUCTS OLT Plus Series - Connection Diagram OLT40 This oilless tank mounted air ice compressor is UL1450 listed A Series for use in sprinkler systems. System Layout t oN MAIN POWER 0 —• INDUSTRIAL DISCONNECT °'` SWITCH 7:::,,ETRAIIN, NOTES: PRESSURE SWITCH 1.MOST MOTORS ARE MULTIPLE VOLTAGE.CHECK NAMEPLATE LENGTH MUST BE WIRED IN FOR CORRECT INTERNAL CONNECTIONS FOR VOLTAGE CIRCUIT TO CONTROL BEING SUPPLIED TO UNIT. COMPRESSOR 2.ALL WIRING TO BE IN ACCORDANCE WITH THE APPUCABLE STATE,LOCAL,AND NATONAL CODES AND SHOULD BE APPROVED BY AK I H z Z 7GENERAL AIR TO SYSTEM U uj J T Pressure Switch Connection PRESSURE SWITCH Ground Terminals DiagramAr,,,,r Note:Location of pressure switch varies based on OO 0 model.This is a general diagram of components.For Adjustment Screw • & 0 Differential Adjustment Screw help specific to your switch please contact General Air 1�``� Products. Motor `1 rj Motor Line ~� O 6 Line LogE Warning: Failure to consult with a licensed electrical professional can result in serious personal injury or death. Disconnect all power before servicing. Undersized wire between the motor and the power source will limit the starting and load carrying abilities of the motor causing motor overheating and permanent damage to the motor.Wire sizes listed are recommendations only- consult the National Electric Code (NEC) and any applicable local electrical safety codes. The NEC and GAP recommends a maximum voltage drop of 3%. Install motors and related equipment in accordance with the National Electrical Code (NEC) local electrical safety codes and practices. It is always the electrician's responsibility to determine and install a wire size that ensures motors can start and run well. www.generalairproducts.com 1-800-345-8207 �.r.–�— — —ate■asr� — * IMMO 11111/1111111111 NM MINININ11111111111111lik AI= NM Electrical '�� — Specs on AIR PRODUCTS page 2! OLT Plus Series - Single Phase, Tank Mounted Air Compressors for Dry Pipe Sprinkler Systems O LT Ul This oilless tank mounted air compressor is UL1450 listed 4, ® for use in sprinkler systems. Series ____At - Oil Less Piston Compressor - Vibration Isolation Pads (4) - UL Listed Pressure Switch - Integrated Air Intake Filters • -ASME Coded Tank (standard) - Customized Motor Windings , r,` t `.14_ . a - Bubble tight air check valve - Fully automatic, direct drive - Permanently lubricated bearings - 60 Hz (cycle) - 30" SS Flex Hose (NEW) - Max Pressure: 60 PSI - Specifically designed to fill the system to 40 PSI in 30 minutes System `.: odelAverage ' Motor Minimum Dimensions Tank Size Weight 'Capacity** Number CFM* HP Wire al. lbs Size + L I W H (gal.) (lbs) 125 gal. T OL12516ACT 1.52 1/6 12 34" 13" 27" 10 76 250 gal. OL25033ACT 3.03 1/3 12 34" 13" 27" 10 77 365 gal. OL36550ACT 4.43 1/2 12 34" 15" 25" 10 84 430 gal. OL43075ACT 5.21 3/4 10 34" 15" 25" 10 96 615 gal. OL615100ACT 7.46 1 6 34" 15" 25" 10 96 915 gal. OL915150ACT 11.10 1 1/2 6 38" 16" 28" 20 135 1225 gal. OL1225200ACT 14.85 2 10 38" 16" 29" 20 145 Accessories Required By Code: 11111:ice ■ Magnetic Line Starters - Thermal Overload Protection ! r 4.14i Single Phase $' 208/230V Size Model C7 p 0 1/3 HP 1 HP 00 MGOOA w . * . 4 Maximum r1 HPIIMPF11.1110A t wr HP 2 HP 3 HP 1 MGO1A 3 HP "°ltHP 1 M G15A VOLTAGE:All Units 115 or 208-230 Volt except When Ordering a Motor Starter you must specify OL1225200ACT which is 208-230 only HP, Voltage and Phase that is supplied to the motor. *Average CFM is the average free air delivery Air Maintenance Devicein from 0 to 40 PSIG. Part#AMD-1 + Based on 100 foot run at weakest electrical supply. Our UL / FM Approved air maintenance Consult Factory for longer or shorter runs. device is required on each system ** Based on 70°F system temp. attached to a tank mounted compressor. For other conditions consult factory for pump up times. www.cieneralairproducts.com 1-800-345-8207 P POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC UL,ULC,and FM Approved Sizes Available: 6"(150mm),8"(200mm)and 10"(250mm) Voltages Available: 24VAC 120VAC 12VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized Service Use: Fire Alarm General Signaling Burglar Alarm s. x Environment: Indoor or outdoor use(See Note 1) 40°to 150°F(-40°to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No.18 AWG stranded wires FM DC Bells-Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101mm)square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30°to 150°F(-34°to 66°C) deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No.1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA128 1750080 .12A 90 77 10(250) 12VDC MBA1210 1750060 .12A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-1 or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5400776-REV Y PAGE 1 OF2 5/08 '1 VSR-F PPOTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULC and CSFM Listed,FM and LPCB Approved,NYMEA Accepted,CE Marked Service Pressure: Up to 450 PSI(31 BAR) Minimum Flow Rate forAlarm:10 GPM(38 LPM) Maximum Surge: 18 FPS(5,5 m/s) Contact Ratings: Two sets of SPDT(Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2"conduit Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and ;. , die-cast housing. • NEMA 4/IP54 Rated Enclosure-use with appropriate conduit fitting. • Temperature Range: 40°F/120°F, 4,5°C/49°C • Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. SizesAvailable: Steel Pipe schedules 10 thru 40,sizes 2"thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 U.S.Pat.No.3921989 One or two family dwelling NFPA-13D Canadian Pat.No. 1009680 Residential occupancy up to four stories NFPA-13R Other Patents Pending National Fire Alarm Code NFPA-72 Potter Electric,Rd.,1990 Optional: Cover Tamper Switch Kit,Stock No.0090018 GENERAL INFORMATION INSTALLATION: See Fig.2 The Model VSR-F is a vane type waterflow switch for use on wet These devices may be mounted on horizontal or vertical pipe. On sprinkler systems. It is UL Listed and FM Approved for use on steel horizontal pipe they should be installed on the top side of the pipe pipe;schedules 10 through 40,sizes 2"thru 8"(50mm thru 200mm). where they will be accessible.The units should not be installed within LPC approved sizes are 2" thru 8"(50mm thru 200mm). 6" (15cm)of a fitting which changes the direction of the waterflow or within 24" (60 cm)of a valve or drain. The unit may also be used as a sectional waterflow detector on large systems. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill.The 2"(50mm)and 2 1/2"(65mm)devices require a The unit contains two single pole,double throw,snap action switches hole with a diameter of 1 1/4"+1/8"-1/16"(33mm±2mm).All other and an adjustable, instantly recycling pneumatic retard.The switches sizes require a hole with a diameter of 2" ±1/8"(50mm±2mm). are actuated when a flow of 10 gallons per minute(38 LPM)or more occurs downstream of the device.The flow condition must exist for a Clean the inside pipe of all growth or other material for a distance equal period of time necessary to overcome the selected retard period. to the pipe diameter on either side of the hole. ENCLOSURE: The unit is enclosed in a general purpose, die-cast Roll the vane so that it may be inserted into the hole;do not bend or crease it.Insert the vane so that the arrow on the saddle points in the housing.The cover is held in place with two tamper resistant screws direction of the waterflow. Install the saddle strap and tighten nuts which require a special key for removal. A field installable cover alternately to an eventual 20 ft-lbs.(27 n-m)of torque(see Fig.2).The tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for vane must not rub the inside of the pipe or bind in any way. installation instructions of this switch. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MKT.#8800001-REV X PAGE 1 OF 2 MFG.#5400761-3/07 , ., SAMMYSTM VERTICAL MOUNT food 1/4" 8001957 20 GST 750 1/4 x 3/4 25 5.93 125 1/4" 8002957 21 GST 100 1/4 x 1 25 6.25 125 '' 1/4" 8003957 22 GST 200 1/4 x 2 25 8.13 125 1/4" 8004957 23 GST 300 114 x 3 25 9.38 125 1/4" 8005925 24 GST 600 1/4 x 6 25 11.25 125 3/8" 8006957 10 GST.75 1/4 x 3/4 25 5.63 125 trW 3/8" 8007957 11 GST 10 114 x 1 25 5.93 125 f 3/8" 8008957 12 GST 20 1/4 x 2 25 7.50 125 3/8" 8009925 27 GST 25-380 3/8 x 2-1/2 25 11.56 125 4Q- .7-- 3/8" 8010957 30 GST 30 1/4 x 3 25 8.75 125 3/8" 8011925 403 GST 40 1/4 x 4 25 10.00 125 3/8" 8012925 14 GST 60 1/4 x 6 25 11.25 125 1/2" 8013925 8 GST 2 1/4 X 2 25 8.75 125 1/2" 8014925 6 GST2.5-380 3/8X2-1/2 25 12.50 125 1/2" 8015925 15 GST 3 1/4 X 3 25 13.13 125 1/2" 8016925 16 GST 4 1/4 X 4 25 13.25 125 1/2" 8017925 17 GST 6 1/4 X 6 25 13.69 125 Steel 1/4" 8024957 50 DSTR 100 1/4-20 X 1 25 7.81 125 1/4" 8025957 51 DST 100 1/4-14 X 1 25 6.56 125 1/4" 8026957 52 DST 150 1/4-14 X 1-1/2 25 6.88 125 1/4" 8027957 53 DST 200 1/4-14 X 2 25 7.50 125 1/4" 8028957 54 DST 250 1/4-12 X 2-1/2 25 8.44 125 1/4" 8029957 55 DST 300 1/4-14 X 3 25 9.06 125 7.1 1/4" 8030957 56 TEK 500 12-24 X 1-1/2 25 6.88 7.75 125 Nut Driver Win Q 3/8" 8037957 29 DSTR 1-1/2" 12-24 X 1-1/2 25 125 Use#14 Nut Driver ' 3/8" 8038957 30 DSTR 1" - 1/4-20X 1 25 78, 125 forSammysand �+Q,- 3/8" 8039957 31 DSTR 516 5/16-18 X 1-1/4 25 7.06 125 Swivel Head 3/8" 8040957 32 DST 10 1/4-14 X 1 25 6.94 125 3/8" 8041957 33 DST 15 1/4-14 X 1-1/2 25 6.56 125 3/8" 8042957 34 DST 20 1/4-14 X 2 25 6.88 125 3/8" 8043957 35 DST 25 1/4-14 X 2-1/2 25 7.81 125 3/8" 8044957 36 DST 30 1/4-14 X 3 25 8.44 125 Q• 3/8" 8045957 37 DST 516 5/16-18 X 1-1/4 25 7.50 125 3/8" 8046957 38 TEK 50 12-24 X 1-1/2 25 6.88 125 1/2" 8031925 601 DST 2.0 1/4-14 X 2 25 8.44 125 part#8113910 1/2" 8032925 1113 DST 2.5 ''''1/4-14 X 2-1/2 25 9.06 125 Item#100 1/2" 8033925 422 DSTR 1.0 1/4-20 X 1 25 6.25 125 1/2" 8034925 28 DSTR 5.16 5/16-18 X 1-1/4 25 10.00 125 1/2" 8035925 443 DST 5.16 5/16-18 X 1-1/4 25 8.44 125 1/2" 8036925 5 TEK 5.0 12-24 X 1-1/2 25 7.50 125 Ion crete 1/4" 8058957 64 CST 200 5/16 x 1-1/2 25 8.44 125 3/8" 8059957 61 CST 20 5/16 X 1-1/2 25 7.81 125 1/2" 8060925 66 CST 2 5/16 X 1-1/2 25 8.75 125 _di.. 0 TOLCO www.tolco.com N1E3CO Revision 12/18/2008 Fig. 200 - "Trimline" Adjustable Band Hanger cgs ME Fig. 200R (Import) - "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range — 1/2" thru 8" pipe ,, Material — Carbon Steel, Mil. Galvanized to G90 �, specifications Function — For fire sprinkler and other general piping $i i purposes. Knurled swivel nut design permits hanger \ ® ;::_� adjustment after installation. \ /; Features — - I B ; • (1/2" thru 2") Flared edges ease installation for t B I /!;' all pipe types and protect CPVC plastic pipe 11 - .' /% ;,' from abrasion. Captured design keeps adjusting A nut from separating with hanger. Hanger is eas- ily installed around pipe. A �` • (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Fig.200 1"-2" Fig.200 21"-8" Approvals — Underwriters' Laboratories listed AP (1/2" thru 8") in the USA(UL) and Canada (cUL) Iwo for steel and CPVC plastic pipe and Factory Mutual ��� MP, Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and ®/ -�. Manufacturers Standardization Society SP-69, Type /' / 10. B / / Niki -- // ii I - Maximum Temperature — 650°F e ; :+,...- ,i 1l Finish — Mil. Galvanized. Stainless Steel materials will I ; be supplied with (2) hex nuts in place of a knurl nub. " - /, ;+ //, Order By — Figure number and pipe size _ ' ' j a ' Note — Figure 200R (import) with retainer ring and A non-captured knurl nut. Fig.200R 21h"-8" Fig.200R 1/2"-2" Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21 400 11 1 3/8 8mm or 10mm 33/8 2% 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 3% 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/ 3/8 10mm 5% 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31,. 3/8 10mm 7% 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101A 63 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA.CA 92879•PH: 951.737.5599•FAX: 951.737 0330 CUSTOMER SERVICE•800.786.5266 II www.tolco.com Page 5 of 6 NIKING® MIRAGE STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Maximum Sprinkler Base NPT Thread Size Nominal K-Factor FM Approvals' Part No.' SIN Water Working (Refer also to Design Criteria below.) Inch mm U.S. metric2 Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) AW1,BX1 Cover Plate Assembly Temperature Ratings" Cover Plate Assembly Finishes' Sprinkler Temperature Ratings W- 139 °F (59°C) cover 13504", 13642' (large diameter), 1 - Polished Chrome, Brushed Chrome, Bright A- 155°F (68 °C) or 15394' (square cover plate) Brass, Antique Brass, Brushed Brass, B-175°F(79°C)and 200°F(93°C) X-165°F(74°C)cover 13504'. 13642' (large diameter),or Brushed Copper, Painted White, Painted 15394" (square cover plate) Ivory, or Painted Black Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing.Other approvals may be in process. Check with the manufacturer for any additiona approvals. The 139°F(59°C)cover has an orange label. The 165°F(74°C)cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. FM Approval Reauirements; Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to. but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 Rev 15.1 Page 3 of 6 ® MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES f- 3 Ordinary 155 °F (68° C) 100 °F (38 °C) 135 °F (57 °C) cULus Red 139 °F 59 °C FM and LPCB Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F 93 °C) 150 °F (65 °C) 165 °F 74 °C Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass,Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory,or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings': ENT oo notes 'The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. Thes= tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, includin• the waterway, but the Belleville spring is exposed. NPT Thread Nominal Maximum Listings and Approvals` Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' Inch mm U.S. metric' Pressure cULus' NYC VdS' LPCB CE Standard Response Applications 13503A VK462 1/2' 15 5.6 80.6 175 psi(12 bar) -- -- AY1,CZ1 AY1, BZ1 AY1,CZ1° AV1,CW1 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) AV1, BX1 AV1, BW1`5 - - -- -- 13503JN" VK462 1/2' 15 5.6 80.6 175 psi(12 bar) AV1, BX1 AV1. BW16 - - -- -- 13667A VK463 1/2' 15 5.6 80.6 250 psi(17.2 bar)' AV1, BX1 AV1. BW16 -- -- -- -- Cover Plate Assembly Temperature Ratings° Sprinkler Temperature Ratings V- 135°F (57°C)cULus Listed cover 13504'. 13642' (large diam- Cover Plate Assembly Finishes10 eter),or 15394' (square cover plate) 1 - Polished Chrome, Brushed Chrome. Bright Brass, A-155°F(68°C) W-165°F(74°C)cover 13504'or 13642' (large diameter) B-175°F(79°C)and 200°F(93°C) X-165°F(74°C)cover 13504',or 13642' (large diameter) Antique Brass, Brushed Brass, Brushed Copper, C-200°F(93°C) Painted White, Painted Ivory,or Painted Black Y-135 135°F(57°C)cover 13504' LPCB Approved as 139°F(59°C) Z-165°F(74°C)cover 13504' Footnotes ' Part number shown is the base part number. For complete part number,refer to current Viking price list schedule. Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. 'This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional ap- provals. `Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E.Vol. 32. 'VdS Approved.standards VdS 2344:2005-12.VdS 2100-25:2008-01.and EN 12259-1:1999+A1:2001 +A2:2004+A3:2006,Certificate G4080021. e((Certified. Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 9 The 135/139°F cover has an orange label.The 165°F(74°C)cover has a white label. '°Painted finish consists of Polyester Baked Enamel.Other paint colors are available on request with the same listings as the standard paint colors. Listings and approv- als apply for any paint manufacturer.Contact Viking for additional information. cULus Listed as corrosion resistant. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 Rev 15.1 Page 1 of 6 NIKING® MIRAGE® STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-pro- = . file cover assembly that provides up to 1/2" (12.7 mm) of vertical adjustment.The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate.The"push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is cULus Listed as cor- rosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. Viking Technical Data may be found on 2. LISTINGS AND APPROVALS The Viking Corporation's Web site at c �L us cULus Listed: Category VNIV http://www.vikinggroupinc.com. FM Approval: Class 2015 The Web site may include a more recent edition of this Technical Data Page. VdS NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 " ° LPCB Approved: Ref. No. 096e/12 E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 Design Criteria for cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). (Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Rev 15.1 (Added CCCF Approval) Page 2 of 3 ' , NIKING. MICROFASTm QUICK TECHNICAL DATA RESPONSE VERTICAL SIDEWALL SPRINKLER VK306 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking MicrofastQuick Response Vertical Sidewall Sprinkler VK306 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact TheViking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, and Chrome Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Protective Sprinkler '/Wrench Flat Clip -------.....4. , „liki.,,,.4%... Li ,,,a... awls 10896 • Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_060614 Rev 15.1 Sprinkler 126h August 14, 2013 NIKING® INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com A fully stocked spare sprinkler cabinet should be provided for this purpose. (Stock of spare lockrings and escutcheon plates should be available in the spare sprinkler cabinet in addition to the spare sprinkler heads.) 5. Place the system back in service and secure all valves. Check for and repair all leaks. E. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combustion or high ambient temperatures, but have not operated,should be replaced. Refer to the Authority Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY Viking Sprinkler VK410 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. 9. DISCLAIMER THE VIKING CORPORATION DISCLAIMS ANY RESPONSIBILITY FOR DAMAGES OR INJURY(INCLUDING DEATH) CAUSED BY THE OPERATION OR INOPERATION OF SPRINKLERS ARISING OUT OF THE MISUSE OF OR TAMPERING WITH VIKING BRAND SPRINKLERS INCLUDING, WITHOUT LIMITATION, ANY PERSONAL INJURY OR DEATH ARISING OUT OF OR CAUSED BY THE MANIPULATION OF, DISMANTLING OF, OR ATTEMPTED USE OF THE SPRINKLER OR ANY COMPONENT AS AN INSTRUMENT UNRELATED TO ITS INTENDED USE. Form No. F_100998 Revised page replaces page 126a-d dated December 1, 2006. (Added US Patent Number.) Sprinkler 126f August 14, 2013 NIIKING. INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com -------- ----- --- n Nc —---u — --_ __ —— -- — Y __ Y F_____„_____----- Retaining — —I ____j Flnnge Assembly ` re, --7:--z,---.-_-7; r v ---f r vr mor '7 Fit -9, mr _..J Protective Flush/Concealed Lockring-� Sprinkler Shell D A 1771— Sprinkler Wrench—\_/-u-\\ �n and Lockring (Part Number �' Protective-/ Institutional E 08336W/B shown) Sprinkler Shell Escutcheon Installation B Wrench 10551W/B INSTALLATION TIP: Do not install the lockring onto the sprinkler until after the sprinkler nipple has been cut back to ensure the sprinkler is at the desired elevation in relation to the face of the ceiling.The lockring will prove difficult to remove from the sprinkler once it has been installed above the plane of the ceiling.Check final installation by temporarily installing the escutcheon plate onto the sprinkler without the lockring, using the Institutional Escutcheon Installation Wrench. If necessary, re-cut the sprinkler drop nipple as required. Once satisfied with sprinkler level compared to the surface of the ceiling, install lockring and escutcheon plate following steps H through J below.The escutcheon plate cannot be removed after it has been installed with the lockring, so do not install the escutcheon plate with the lockring until after the system has been tested. Figure 4: Sequence of Installation J. As depicted in Figure 4-E, use the Institutional Escutcheon Installation Wrench to screw on the escutcheon plate clockwise. The face of the escutcheon plate is equipped with four indentations to complement the design of the Institutional Escutcheon Installation Wrench 10551W/B and facilitate installation of the escutcheon plate. As the escutcheon plate is threaded onto the sprinkler body, the four arms of the lockring must fully engage with the radial grooves on the inside of the escutcheon plate. Continue to thread the escutcheon plate onto the sprinkler body until the plate's flange fits tightly against the surface of the ceiling. Then, proceed to turn the escutcheon plate another '/ turn clockwise to ensure that it is secured to the ceiling. The arms of the lockring are angled and designed to wedge into the coined radial grooves on the inside face of the escutcheon plate to keep the escutcheon plate from being unscrewed. Thus, an attempt to remove the escutcheon plate after installation is prevented. DO NOT MODIFY THE UNIT. K. The retaining flange, located behind the finished ceiling, must fit snug against the inner surface of the ceiling to prevent vertical movement of the assembly. Use a 1/8" hex wrench to tighten the retaining flange screw and secure the assembly into place to prevent it from being pulled through the ceiling. L. DISASSEMBLY: Refer to section 6. INSPECTIONS, TESTS AND MAINTENANCE, paragraph D. and follow all warnings and instructions. 5. OPERATION The sprinkler is recessed into the mounting surface, flush to the ceiling, with only a portion of the fusible link assembly exposed beneath the ceiling. The concealed deflector is held inside the sprinkler body until the eutectic metal solder link is fused. When the sprinkler fuses,the deflector extends to discharge and distribute water. The multi-piece design allows the installation and testing of the institutional sprinklers prior to installation of the ceiling. The special escutcheon plate on the Institutional Quick Response Flush Pendent Sprinkler assembly is the only ceiling ring that may be used with these institutional sprinklers, and all of these sprinklers must be installed with this escutcheon plate. Removal of the thread-on escutcheon plate is prevented by the lockring. Sprinkler 126d August 14; 2013 NIIKINGe INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com cULus Listing Requirements for Standard Coverage Applications: Sprinkler VK410 is cULus Listed as a Quick Response Flush Pendent Sprinkler for standard areas of coverage as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler must be installed in the pendent position in fixed fire protection systems(wet,dry,deluge,or preaction systems). • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard coverage spray pendent sprinklers must be followed. cULus Listing Requirements for Extended Coverage Applications; Sprinkler VK410 is cULus Listed as a Quick Response Extended Coverage Flush Pendent Sprinkler as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers. • Designed for use in Light Hazard occupancies only. • The sprinkler must be installed in the pendent position in fixed fire protection systems (wet,dry,deluge,or preaction systems). • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 or EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordi- nances, and standards, whenever applicable. B. Viking Institutional Quick Response Flush Pendent Sprinklers are not intended for use in corrosive environments. Use only sprinklers listed for corrosive environments when subject to corrosive atmospheres. C. Use care when locating sprinklers near fixtures that can generate heat. Do not install sprinklers where they will be exposed to temperatures that exceed the maximum recommended ambient temperature for the temperature rating used. D. Adequate heat must be provided when the Institutional Quick Response Flush Pendent Sprinkler is installed on wet-pipe sys- tems. E.The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. Install the sprinklers according to the following sequence: 1. Install all piping and cut the sprinkler drop nipple so that the 1/4" (15 mm) NPT outlet of the reducing coupling is at the desired elevation and centered in a 2-1/4" (57.2 mm) diameter opening in the ceiling (due to lockring). Note: If the retaining flange assembly is to be used, slide the flange over the sprinkler drop nipple prior to threading the nipple into the branch line tee as shown in Figure 4-A. 2.The internal diameter of the special Flush/Concealed Sprinkler Wrench is designed for use with the sprinkler contained in the protective plastic shell. With the sprinkler in the shell, apply a small amount of pipe-joint compound or tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet. 3. Refer to Figure 4-B and use only Sprinkler Wrench 08336W/B or 10366W/B,which is designed for installing Viking Institutional Quick Response Flush Pendent Sprinklers. With the sprinkler in the plastic protective shell, place the unit into the wrench. DO NOT use the fusible link to start or thread the sprinkler into a fitting. Turn the unit clockwise to thread the sprinkler into the coupling, taking care not to over-tighten or damage the sprinkler operating parts. Sprinkler 126b August 14; 2013 NIKING® INSTITUTIONAL QUICK TECHNICAL DATA RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Order Sprinkler VK410 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Polished Chrome= F Temperature Suffix: 165°F (74°C) = C, 220 °F(104°C) = F For example, sprinkler VK410 with a 165°F (74 °C)temperature rating = Part No. 10554FC. Escutcheon Package: US Patent No.6,024,177, Part No. 10627F (includes lockring and escutcheon plate) . Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches*: A. Heavy Duty Part Number 08336W/B Available since 1983, or B. Light Duty Part Number 10366W/B**Available since 1998. *Requires a'/2'ratchet(not available from Viking). **Ideal for sprinkler cabinets. Institutional Escutcheon Installation Wrench: Part No. 10551W/B (available since 1999) Spanner Wrench: Part No. 10729***(for removal of institutional escutcheon plate),2-1/2"C-C(available since 1999) ***For removal of the Institutional Quick Response Flush Pendent Sprinklers,special tools are needed (not all the required tools are available from Viking). Refer to section 6. INSPECTIONS,TESTS,AND MAINTENANCE,paragraph D.on pages 126g-h. Sprinkler Cabinet: Six-head capacity: Part No. 01731A(available since 1971) Retaining Flange Assembly: Part No. 10599, includes: Retaining Flange Casting:AISI C1045 Low Carbon Steel (available since 1999) Thickness: 13/32" (10.3 mm) Outside Diameter: 2-3/4" (70 mm) Socket Set Screwtt: Steel Alloy ttRequires a 1/8"hex wrench for installation and removal(not available from Viking). 4. INSTALLATION (Refer to Figures 1-4.) WARNING: Viking sprinklers are manufactured and tested to meet the rigid requirements of the approving agency.The sprinklers are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation. Flush sprinklers are decorative sprinklers and may be considered special purpose.As such, some Authorities may limit the use depending on the occupancy classification. Refer to the Authority Having Jurisdiction prior to installation. A. Sprinklers must be handled with care.They must be stored in a cool,dry place in their original shipping container. Never install sprinklers that have been dropped, damaged in any way, or exposed to temperatures in excess of maximum ambient tempera- ture allowed. Such sprinklers should be destroyed immediately. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 165°F (74°C) 100 °F (38°C) Intermediate 220°F (104°C) 150°F (65°C) Sprinkler Finish: Polished Chrome Footnotes ' The sprinkler temperature rating is stamped on the sprinkler. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Page 6 of 6 NII<ING MICROFAST®QUICK TECHNICAL DATA RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 2-3/4" 2-7/16" Minimum 1-441— (68 mm) ♦► 1-7/8" (62 mm) �(48 mm fr1 !r' ,.:; 2-1/8" ' \ MawV_' 1111611 mm) I (672-5/8" mm) Maximum Wall Opening Size: Installed with a Standard Installed with a Microfast 2-5/16" (58.7 mm) minimum 1/8" Surface-Mounted Model F-1 Adjustable 2-1/2" (63.5 mm) maximum Escutcheon Escutcheon Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Minimum Minimum 1-5/8" 1-3/4" (41 mm) (45 mm) t tr 2-1/8" t tP"* 2- 118" (54 mm) (54 mm) 2-1/4" 2-5/8" ' ..1 .0 Poll , (57 mm) (67 mm) Maximum Maximum Wall Opening Size: Installed with the Installed with the 2-5/16" (58.7 mm) minimum Micromatic Model E-1 Threaded Model E-2 Recessed Escutcheon Recessed Escutcheon 2-1/2" (63.5 mm) maximum Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_060914 16.01.28 Rev 16.1 Replaces form F_060914 Rev. 14.2 (Revised temperature suffix designation) Page 4 of 6 MICROFAST® QUICK , VIKING TECHNICAL DATA RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Thread Size Nominal K-Factor Overall Length Listings and Approvals' Base Part SIN Sprinkler (Refer also to Design Criteria on page 43x.) Number' Style 2 4 Ka NPT BSP U.S. metric Inches mm cULus LPCB IKMI 12997 VK305 HSW 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X, -- __ C2W, D2Z NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 12121 VK305 HSW 1/2" 15 mm 5.6 80.6 1-11/16 68 MY,81X, C2W, D2Z Approved Temperature Ratings Approved Escutcheons A 135 °F (57 °C), 155 °F (68 °C), 175 W-Installed with standard surface-mounted escutcheons °F (79 °C), 200 °F (93 °C), and 286 °F X-Installed with standard surface-mounted escutcheons or (141 °C) Approved Finishes the Viking Microfasta Model F-1 Adjustable Escutcheon, B - 135 °F (57 °C), 155 °F (68 °C), 175 °F 1 - Brass, Chrome, White Poly-ester", or recessed with the Viking Micromatic'Model E-1, E-2, (79°C), and 200°F (93°C) and Black Polyester'6 or G-1 Recessed Escutcheon C 155 °F (68 °C), 175 °F (79 °C), 200 °F 2- ENT' Y-Installed with standard surface-mounted escutcheons or (93°C), and 286°F (141 °C) the Viking Microfast/ Model F-1 Adjustable Escutcheon D- 155°F(68°C), 175°F (79°C), and 200 Z-Installed with standard surface-mounted escutcheons or °F(93°C) recessed with the Viking Micromatic Model E-1 Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listin.s and Ap.rovals as the standard colors. cULus Listing Reauirements; Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • Locate with the deflector 4P to 12"(102 mm to 305 mm) below the ceiling. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Align the top of the deflector parallel with the ceiling. • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_060914 16.01.28 Rev 16.1 Page 2 of 6 VIKING MICROFAST®QUICK TECHNICAL DATA RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat 10896 • 4 4 Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_060914 16.01.28 Rev 16.1 Page 4 of 4 NIKING® MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria below.) 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A1, B2 NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 06661B VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155°F (68°C), 175 °F(79°C), 200°F (93°C), and 286°F (141°C) 1 - Brass, Chrome, White Polyesters, and Black B- 155 °F (68 °C), 175°F(79 °C), 200 °F (93°C), and 286°F (141°C) Polyesters 2- ENT6 Footnotes "Base part number is shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. s FM approved as corrosion resistant. FM Approval Reauirements: The Microfasr Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements. reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 14.2 (Added 06661 B) Page 2 of 4 ® MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast(''Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary / 135°F(57°C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F (38°C) Red Intermediate 175°F(79°C) 150°F(65°C) Yellow Intermediate 200°F(93°C) 150°F(65°C) Green High 286°F (141 °C) 225 °F(107°C) Blue Sprinkler Finishes: Brass, Chrome,White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings':White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135°F(57°C) Footnotes 'The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester. ENT,and PTFE coatings. For ENT coated automatic sprinklers,the waterway is coated. Protective Sprinkler Cap Wrench Flat 10896 • Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_052114 Rev 14.2 Page 6 of 6 MICROFAST® QUICK NIKING® TECHNICAL DATA RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 1/2" 2-1/2" (63.5 mm) maximum (15 mm) NPT 2-1/8" (54 mm) 4'4 t .4:f',I.,- ♦ 1-1/2" 2-1/4" 1-3/4" 2" (38 mm) (57 Imm) (44.5 mm) (51 mm) Min. i + Max. , Installed with a standard Installed with a Microfast Note:At maximum,adapter is 1/8" surface-mounted Model F-1 Adjustable exposed 1/2"(12.7 mm)from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon 111 1111111 Ceiling Opening Size: 2-5-16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" 2-1/8" (54• mm) 4 mm) •l ��,� .Its , r .,. • Ar54 ., 41-1/8" 4 1 1-1/8" 1-3/4" T (28.6 mm) 2" (28.6 mm) (44.5 mm) Min. (51 mm) Min. Max. Max. J Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 Rev 14.2 (Added 06662B and 18021) Page 4 of 6 II(II1G® MICROFAST® QUICK TECHNICAL DATA MICROFAST® PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com BaseThread Size Nominal Overall Listings and Approvals' Part SIN Sprinkler K-Factor Length (Refer also to Design Criteria.) Style Number NPT BSP U.S. metrics Inches mm cULus` VdS LPCB 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y,D2,C2X Al A1Z, B1Y D1Z, C1Y -- NOTICE-Product Below-Limited Availability(Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y,D2,C2X -- -- -- -- 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1X, B1Y Al A1X, B1Y D1X,C1Y5 D1X,C1Y' Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F(57 °C), 155 °F (68 °C), 175°F 1 -Brass,Chrome,White X-Standard surface-mounted escutcheon or the (79°C),200°F(93°C),286°F(141 °C) Polyester56, Black Polyes- Viking Micromatic®Model E-1 Recessed Escutcheon B- 135°F (57 °C), 155 °F (68 °C), 175°F ter' Y-Standard surface-mounted escutcheon or the (79°C),and 200°F(93°C) 2-ENT` Viking Microfast®Model F-1 Adjustable Escutcheon,or recessed with the C-155°F (68 °C), 175 °F (79 °C), and Viking MicromatiO Model E-1, E-2,or E-3 Recessed Escutcheon 200°F(93°C) Z-Standard surface-mounted escutcheon or the D-155°F (68 °C), 175 °F (79°C),200°F Viking Microfastt Model F-1 Adjustable Escutcheon (93°C),286°F(141 °C) Footnotes ' Base part number shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc.for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 'CE Certified. Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. cULus Listing Reauirements;, The Viking Microfast'Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 14.2 Page 2 of 6 II(IIIG® MICROFAST® QUICK TECHNICAL DATA MICROFAST® PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for Recessed Pendent Sprinklers: Part No. 16036W/B** (available since 2011) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/z"ratchet is required (not available from Viking). "**Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection. Testing and Maintenance requirements. 7. AVAILABILITY The Viking MicrofastT Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Wrench Flat Clip Protective Sprinkler Cap 10896 • Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 Rev 14.2 Sprinkler 105f October 25; 2010 VIKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ambient Exposed Barrel Install 1 inch NPT threaded Deflector at / Ambient Temperature end of drypendent sprinkler Temperature 40•F/4•c150•F/10'C160•r/16•C — into the 1 Inch NPToutlet minimum distance of Protectedbelow ceiling Area' at the Exposed Minimum Barrel 1n of a malleable Iron tee fitting Discharge End Length's Face of Tee Y per ANSI B 16.3 (Class 150) of the Sp,WAer to Top of Ceiling Up to 2' (50.8 mm) In.(re) In.(re) In.(mm) or cast iron threaded tee fitting adjustment available. 40•F (4'C) 0 0 0 ! , per ANSI 16.4 (Class 125) only. 30'F (-1•C) 0 0 0 Minimum ceilingopeningdiameter ®I Note 20'F (-TC) 4 (300) 0 0 To locate the 1-3/4' (44.5 mm) deflector at the 10'F (-12'C) 8 (203) 1 (254) 0 _(Exposed I 2-7/16' minimum distance 0'F (-18•C) 12 (305) 3 (76) 0 Barrel) / below the ceiling, C) Maximum ceiling opening diameter, L 2-1/4' (57 mm). (61.9 mm) with no upward -10'F <-23' 14 (356) 4 (102) 1 (2S4) -20•F (-29•C)14 (356) 6 (152) 3 (76) Seal the clearance I Minimum adjustment avail- / space around the I I able, order the -30'F ( 34•()16 (406)8 (203)4 (102) - p dry pendent sprhk- -40'F (-40'C)18 (457)8 (203)4 (102) sprinkler to avoid leak- ler 1' (25.4 mm) -50•F (-46'020 (508)10 (254)6 (152) ��_ • age of air into the shorter than the 1-- i i-2protected area and g�l�l 'A' dimension. -60'F (-51'C)20 (508)10 (254)6 (152) \ / 13/16' consequent formation :1WPRRM Ceiling (20'6 mm) of condensate around Nair the frame, which could Note! Inhibit operation or To locate the i ( Sleeve finish cause premature opera- 4-7/16' deflector at the 1-1/2' (38.1 mm) —matches tion. Refer to Figure (1127 mm) maximum distance diameter escutcheon 7 below. Maximum below the ceiling, with no downward If humidity and temp- adjustment avail- 3-1/16' erature differential able, order the (Protected Area) causes condensation I dry pendent sprink (77.8 mm) on the exposed dry ler 1' (25.4 mm) sprinkler, consider Deflector at longer than the wrapping the exposed 'A' dimension. barrel with insulation, maximum distance foam insulating tape, below ceiling or equivalent. eThe protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. eeThe minimum required barrel length Is not the same as the 'A' dimension. Refer to Figures 3-5 for the 'A' dimension. NOTE! Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Seal Part No. 13864 ■ (or equivalent method) Seal MEIN ipiiii iii. _ . ClearanceNIIIIIPPP Insulated ® Opening ■ Ceiling ■ I i. Dry Sprinkler Seal on the Dry Sprinkler Seal Within the Ceiling Exterior of' the Ceiling Figure 7: Dry Sprinkler Seal(Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_031793 Replaces page 105a-f, dated August 12, 2010. (Revised sprinkler materials.) Sprinkler 105d October 25, 2010 VIKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals' Sprinkler SIN Style (Refer also to Design Criteria below.) Base Part No.' NPT BSP U.S. metric' Inches mm cULuss NYC' VdS LPCB (E 4$1- 08383U Adjustable 1" -- 5.6 80.6 1/2" 12.7 Al Al -- -- -- -- VK176 Standard -- 25 mm -- 80.6 1/2" 12.7 Al 16457.1 -- -- -- -- -- 08385U Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2 B2 -- -- 16453U VK180 Recessed -- 25 mm -- 80.6 1/4" 6.35 B2 -- 08387U Plain 1" -- 5.6 80.6 1/2" 12.7 A3 A4 VK172 16455U Barrel -- 25 mm -- 80.6 1/2" 12.7 A3 -- -- -- -- -- Approved Temperature Ratings Approved Finishes and "A" Dimensions A- 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), 1 -Chrome-Enloy®or White Polyester'sprinkler with a Chrome-Enloy®or White Polyester Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) and 286°F(141 °C) 2-Chrome-Enloy®or White Polyester'with"A"dimensions 3-1/4"to 47-1/2°(82.5 mm to 1,207 mm) B 155 °F (68 °C), 175 °F 79°C and 200 °F 3-Chrome-Enloy®, Brass,or White Polyester' with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) (93°C) 4-Chrome-Enloy®or Brass with "A"dimensions 3"to 47" (76.2 mm to 1,194 mm) Footnotes • Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 'K-Factor applies for standard lengths("A"Dimensions indicated above). ' Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. °This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 6 Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 15. cULus Listed as corrosion resistant. 0 NOTE:When using CPVC fittings with Viking dry sprinklers,use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Reauirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler 105b October 25, 2010 NilKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2"to 45-1/2" (38.1 mm to 1,156 mm)for the adjustable standard style, 3"to 47"(76.2 mm to 1,194 mm)for the plain barrel style, and 3-1/4"to 47-1/2" (82.5 mm to 1,207 mm)for the adjustable recessed style. Lengths exceeding the standard lengths are available,with no approvals, on a"made-to-order" basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm).Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass =A, Chrome-Enloy'' = F, and White Polyester = M-/W Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = D, 200°/93° = E, 286°/141° = G For example, sprinkler VK176 with a Chrome finish and a 155 °F/68 °C temperature rating, and "A" length of 10" = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Wrench111111 Sprinkler Wrenches: Flat Protective A. Standard Wrench: Part No. 07297W/B (available since 1991) 1wKwiffi1 B. Wrench for recessed sprinklers: Part No. 07565W/B** Sprinkler ■ i Shield (available since 1991) O **A'A"ratchet is required (not available from Viking). Alp/pi Sprinkler Guard: Chrome, with no listings or approvals, for installation it ` - on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: A.Adjustable Standard Dry Escutcheon: Base Part No. 07741 ` B. Recessed Dry Escutcheon Cup: Base Part No. 05459A VIKING 07297 O J 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Figure 1: Standard Sprinkler Wrench 07297W/B 5. OPERATION During fire conditions, the heat-sensitive liquid inNMI — the glass bulb expands, causing the glass to __mmi smi shatter, releasing the internal parts to open the -==_ -_ waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming ammimmi uniform spray pattern to extinguish or control the fire. Sprinkler Wrench 6. INSPECTIONS, TESTS & MAINTENANCE j o7565w/B** must be used for installing Refer to NFPA 25 for Inspection, Testing and recessed dry Maintenance requirements. sprinklers _,,_ is i__. 11 Is--.ti I 5— 1.,2:,. :__1 !His,. mos- 7. AVAILABILITY Step 2 Carefully press The Viking Quick Response Dry Pendent Sprink- I��r, the wrench upward and lip 1 ler is available through a network of domestic Wit% turn slightly to ensure and international distributors. See The Viking - engagement with the sprinkler wrench flats. Corporation web site for the closest distributor or contact The Viking Corporation. Step 1, carefully voNA 1/2' ratchet Is t 1 slide the wrench required (Not avail- 1 I sideways around the 1111 able from Viking.) 8. GUARANTEE sprinkler deflector. For details of warranty, refer to Viking's current Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers list price schedule or contact Viking directly. Preaction 3301 January 6,2012 ' HI(IF1G ® 2" MODEL G-2000P TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC/PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 0 / ! Preaction 330j January 6, 2012 A 2" MODEL G-2000P NIKING TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRICPNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1U" Section of d' Schedule 10 Pipe & Part Number 16188-1: It 2" Coupling Air 1 Model G-2000P Valve Pre,,"ure Supervisory 1 G-2000P Double Interlock, Electric/ tea' II/ Sw tr„ Pneumatic Release Trim (Includes NC Solenoid & Pneumatic Actuator) �� **) 1 ,�•^,�1 :t.-�l- 1 10" Section of Schedule 10 Pipe and 0`. vii io• � Coupling �1Tr,i ` 1 Air Pressure Supervisory Switch (PS40-2A) r�ir ,�, _..4.1&4 � ►:�_ 401 1 Alarm :: : : 0 2A) ater it >>._ :l3_ok„r41 .. r G-2000P Valve and \I h1�♦,���q�,, �,: i Preaction Trim Alarm 1��� f(r �•� •'��1] Pressure 'fs,/i(J ' �,(i , ob .a.� bawl Switch A�LIT_. fey r ..... rr r Water Supply g joi 0V Control Valve '1 -r�J1(,r, �, Figure 8 - 16188-1 Assembly Model E-1 Accelerator fir Accessories: Ng Vent to 08055 Model E-1 Accelerator 4%0g 1 Atmosphere 14800 Model LD-1 Anti-Column Device `,�,`is� 16211 Drain Manifold at, r `is .i0 It I .4 e ..,4,,, _ IF, ,.: 1110:11; .tea r - �I• �1-41;11,y ! Drip _. I ''(, Cup 4.0 ��' _ ' Check -fir l (`�ah1� �, ct Valve a • �/ �� i (•' " Drain Model LD-1 ili 1 Manifold Detail Anti-Column -7 fi :.-t-'; v Device CIO Drain �';�� Manifold Figure 9 - Optional Accessories Preaction 330h January 6, 2012 R 2" MODEL G-2000P N1KINGTECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC;PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 6. INSPECTION AND OPERATIONAL TEST NOTICE: THE OWNER IS RESPONSIBLE FOR MAINTAINING THE FIRE PROTECTION SYSTEM AND DEVICES IN PROPER OPERATING CONDITION. It is imperative that the system is inspected and tested on a regular basis in accordance with NFPA 25. The frequency of the inspections may vary due to contaminated water supplies, corrosive water supplies, corrosive atmospheres, as well as the condition of the air supply to the system. For minimum maintenance and inspection requirements, refer to NFPA 25. In ad- dition,the Authority Having Jurisdiction may have additional maintenance,testing, and inspection requirements that must be followed. Viking does not require internal inspection of the valve as part of routine inspection and testing. Internal maintenance is generally only required for valve repairs and internal component replacement. WARNING: Any system maintenance that involves placing a control valve or detection system out of service may eliminate the fire protection capabilities of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected areas. A. Low Air Pressure Alarm Test: (Refer to Figure 5) Quarterly testing of low air alarms is recommended. To Test Sprinkler System "Low Supervisory Air"Alarm: 1. To prevent operation of the G-2000P Valve and filling the system with water during the test, DO NOT operate the electric detection system during test. Consider closing the main water supply control valve. 2. Fully open the sprinkler system test connection. 3. Verify that low air alarms operate within an acceptable time period and continue without interruption. 4. Close the test connection. 5. Establish recommended pneumatic supervisory pressure to be maintained. Refer to section 4. INSTALLATION. 6. Reset the system release control panel.Alarms should stop. When testing is complete, return the system to service following steps 1 through 8 below. B. Full Flow Trip Test: (Refer to Figure 5) Performance of a trip test is recommended annually during warm weather. Consider coordinating this test with operation testing of the detectors. CAUTION! PERFORMANCE OF THIS TEST WILL CAUSE THE G-2000P VALVE TO OPEN AND THE SPRINKLER SYSTEM TO FILL WITH WATER. To Trip Test the Electric/ Pneumatic Double-Interlocked Preaction System: 1. Notify the Authority Having Jurisdiction and those in the area affected by the test. 2. Trip the G-2000P Valve by performing option "a" or"b" below. a. Operate the electric release control system according to the manufacturer's instructions, and open the sprinkler system test connection. b. Operate the emergency release valve . 3. The G-2000P Valve should open, filling the sprinkler system with water. Water flow alarms should operate. 4. Verify that there is adequate flow from the sprinkler system test valve. When Trip Testing is complete: 5. Perform steps 1 through 13 of section 4.F. PLACING THE SYSTEM IN SERVICE to return the system to service. 6. Notify the Authority Having Jurisdiction and those in the affected area that testing is complete. 7. MAINTENANCE Viking does not require an internal inspection of the G-2000P Valve unless there is an indication of damage to internal components. A. Taking the system out of service: (Refer to Figure 5) 1. Close the water supply main control valve, placing the system out of service. 2. Open the flow test valve located in the base of the G-2000P Valve. 3. Close the air (or nitrogen) supply to the preaction system piping. 4. Close the priming valve. 5. Relieve all pressure from the preaction system piping. If the system has operated, open main drain valve to allow the system to drain completely. B. Removing the Cover from the Body: (Refer to Figures 1 & 11) 1. Remove the 2" grooved coupling from the top of the G-2000P Valve. 2. Remove the 10" section of pipe directly above the G-2000P Valve. 3. Break the 1/2" coupling between the air pressure fauge and air pressure supervisory switch. 4. Remove the 3/4" union below the main drain. 5. Remove the 8 cover screws (8). Preaction 330f January 6, 2012 2" MODEL G-2000P NIKING® TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC'PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5. OPERATION A. In the Set position: When air pressure is introduced into the sprinkler piping,the sensing end of the pneumatic actuator is pressurized.This closes the pneumatic actuator.The closed pneumatic actuator and the normally closed solenoid valve prevent prime water from escaping the prime chamber of the G-2000P Valve. When prime water enters the prime chamber,the rolling diaphragm is pressurized,causing it to expand downward onto the water seat. ,/---\, U() eN ,:.-------5--- I i .'\ _ i / . 0 0 „ .„,, .„4001°..". ,,,.,,..,,,, , • 1�� aux To Air 1'''' Supply' f, r"LP t f' i FL, % �c : .4�j .: ill /Ifir0 `i i v III „ ., ,_,) 1� wr.,,, 1„,„ _, I _ - / �= tf,:; _ii: - } tt I •;r r 111. � � 71 �r III,aii-44,- 1r - "' AL' ---- - :-. -1 40-11,40 4WOilt ' it ,voir,:,....0 . .ir, .. !!'1;bh_q;Al )r, . 'I° i irri: TA pi ea I, ( � '!r' l iii - .U, — III l _ Air I g =_ I Water Figure 6 - Set Position Preaction 330d January 6, 2012 NIKING® 2" MODEL G-2000P TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRIC,PNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com To R ....Control P... dl f1- cr1 Y 4 `I 227 ��I�� SCREwS ADJUSTMENT i' 172971 KNOB �.�� :. j .x 1107.191 R 0 0 0 ® -- 1 WI Y NPT 240 .... 1, LEO ��.'..—:'� 162.1171 f (OLEO 3.78 —.. ,+ 320 Figure 2 - Alarm Pressure Switch Wiring (95.291 18122) (Alarm Pressure Switch should be set to 5 PSI (0.34 bar) FIELD ADJUSTMENTS: pJ4o-.2 Alarm Pressure Switch:The operating point of the switch can be TO RELEASE CONTROL PANE I. adjusted to any point between 4 PSI(0.27 bar)and 8 PSI(0.55 bar) by turning the adjustment knob(s)clockwise to raise the actuation �6L point or counter-clockwise to lower the actuation point. 2 1 `OM Air Supervisory Switch: The operating point of the switches can --- be adjusted to any point between 10 PSI (0.7 bar) and 60 PSI •• 0© Low (4.1 bar) by turning the adjustment knob(s) clockwise to raise the C+ + AIR actuation point or counter-clockwise to lower the actuation point. v v/ y The high and low switches are inde endentl varil�l���ladjustedindependently. liMill EOLR i Figure 3 - Air Supervisory Switch Wiring Figure 4 - Pressure Adjustment Special attention must be given to systems employing a bottled-gas supply. Because only a limited amount of gas is available, small leaks(which normally would go unnoticed in systems being supplied by mechanical compressors) can become critical to the system's overall performance. If the system is to function at temperatures as low as-40°F (-40°C), and, if bottled nitrogen is the gas supply,the system is particularly susceptible to leakage, and special care should be taken to ensure against leaks throughout the entire system. C. Air Supply Installation 1. Install the required air supply as described in section 4.B. The size of the compressor and amount of air required should be determined in accordance with Tables 1, 2 & 3. The air or nitrogen supply to the preaction system must be clean, dry, and oil free. 2. Automatic air supplies must be regulated, restricted, and from a continuous source.A Viking Air Maintenance Device should be installed on each system equipped with a tank mounted compressor, plant air or nitrogen. For compressors with a capac- ity less than 5.5 ft3/min at 10 PSI (0.154 m3/min at 0.69 bar), NFPA 13 does not require an air maintenance device.The use of an air maintenance device with riser mounted compressors can lead to compressor"short cycling". Viking always recom- mends that a tank-mounted compressor with air maintenance device be used. This can become critical when accelerators are installed on the system. D. Pressure Switch Wiring; Wire the Alarm Pressure Switch (PS10)and Air Supervisory Switch(PS40), and adjust the pressure settings as shown in Figures 2-4. E. Hydrostatic Test: The Preaction System, including Sprinkler Piping and Sprinklers shall be hydrostatically tested at 200 PSI (13.79 bar)and maintained for two hours, in accordance with NFPA 13. Systems normally subjected to working system pressures in excess of 150 PSI (10.34 bar) shall be tested at a pressure of 50 PSI (3.45 bar) in excess of system working pressure. F. Placing the Valve in Service: (Refer to Figure 5) When the Preaction System is ready to be placed in service, verify that the pneumatic release system is in a normal condition and that the electric release system has been reset. 1. Verify that the water supply main control valve (not shown) supplying the G-2000P Valve is closed. 2. Close the prime valve. 3. Open the main drain valve. 4. Open the flow test valve. 5. Drain all water from the preaction system. If the system has operated, or if water has entered the system, allow enough time to completely drain the system. January 6, 2012 Preaction 330a 2" MODEL G-2000P NIKING® TECHNICAL DATA DOUBLE INTERLOCK PREACTION WITH ELECTRICTNEUMATIC RELEASE The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-2000P Valve.The small profile, lightweight. pilot operated Viking Model - G-2000P Valve comes complete as shown in Figure 8. The system piping is pressurized with air or nitrogen to serve both as a means of supervising rji the integrity of the piping network and as oneportion of the system release operation. This 9 Y P P 9 Y p feature serves to prevent undetected leaks on the system piping network. If the system piping • (04, Ear,' �� �s or a sprinkler is damaged, the supervisory pressure is reduced and a "low air" supervisory t .• -.4-&1014111 ' C alarm is activated. "�\:,,� vt. e�'' • ;e;n _ This pilot operated externally reset valve also includes an internal check diaphragm, �= �, •�1 which eliminates the need for a separate check valve being installed in the system riser. 46' (f��! '� , A•wti I� iso Double interlocked electric/pneumatic release preaction systems require the use of one 24 �1 ^�( VDC normally closed (NC) electric solenoid and one pneumatic actuator. The electric sole- ��"4` *''11,1(,•,"•+1 is noid is connected to a compatible release control panel and compatible detection devices. ,• :�,..: The pneumatic actuator is controlled by the air pressure that is contained within the sprinkler system piping. In fire conditions, both the solenoid and a sprinkler must open in order for the 404: G-2000P Valve to operate.When both the solenoid and pneumatic actuator open,the priming =•1 �:rii water is relieved from the internal prime chamber assembly. The prime chamber assembly collapses,and water passes through the G-2000P Valve and internal check diaphragm to the system piping network.The entire sprinkler system fills with water. Double interlock electric/pneumatic release preaction systems are commonly used in cold storage applications and other areas where it is important to control accidental water discharge due to inadvertent damage to the sprinkler piping. 2. LISTING AND APPROVALS cOas cULus Listed: VLFT <> FM Approved: Refrigerated Area Sprinkler Systems 3. TECHNICAL DATA Specifications: Pressure Rating: 250 PSI (17.2 Bar)Water Working Pressure Factory Hydrostatically Tested to: 500 PSI (34.5 bar) Friction Loss(Given in feet of Schedule 40 pipe based on Hazen&Williams formula C = 120): QP Model G-2000P Valve: 8.5' Q _ CV 10" Section of Pipe: 1' S Water Supply Control Valve: 1.9' Q= Flow Model G-2000P Valve Cv Factor: 115.6 Valve Color Black Cv= Flow Factor(GPM/1 PSI AP) Material Specifications: AP= Pressure Loss through Valve Refer to Figure 11. S= Specific Gravity of Fluid Ordering Information: Available since 2010. Part Number: G-2000P Double Interlock Electric/Pneumatic Preaction Riser Assembly: 16188-1 (Refer to Figure 8) Accessories: (Refer to Figure 9) Drain Manifold: 16211 Viking Technical Data may be found on Model E-1 Accelerator: 08055 The Viking Corporation's Web site at Model LD-1 Anti-Column Device: 14800 http://www.vikinggroupinc.com. The Web site may include a more recent 4. INSTALLATION: edition of this Technical Data Page. A. General Installation Instructions 1. For proper operation and approval, the valve must be installed in the vertical position as trimmed from the factory. DO NOT modify the factory assembled trim except as described in this technical data sheet. 2. A 10" section of pipe is provided with the G-2000P Double Interlock Electric/Pneumatic Preaction Riser Assembly. Prior to valve maintenance, this section of pipe may be removed to provide clearance for lifting the cover from the body. 3. The G-2000P Valve must be installed in an area not subject to freezing temperatures or physical damage. If required, provide Form No. F_011510 Replaces page 330a-I, dated July 1, 2011. (Revised the replacement parts list and Figure 11.) January 6, 2012 Dry 138m NIKINGR TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 0 ,,,,,/witivcimit_0, 6 4 / " ' '1114$ 0 ir;\\.\\\\ \t1 ......, \ :\\.__.,: 1111 ttt `��\ 4 \ fir •. t t 1 t a_�Z \tt t ;\lltt •s ,\,\ 0.\\\ t •t�Yc.. ...\/10a \tt' Q '6. tt 80 ,t tt tttttt t\tt\t a tot� ta\\.tt\t\— Q a..� \tt -- 11 � 11,0,1.0 ,,,tt ;t1A..,0.\1,1tt ,1104441 ; 0 0LtOlOtt, 44t144b4IN Figure 12 - Model A-1 Differential Valve Item Number er Part Number Description Material Requiredd 1 15459 Seat Brass UNS-C36000 1 2 -- Body Brass UNS-C84400 1 3 14948 Diaphragm Polyester Fabric and EPDM Elastomer 1 4 04735A Upper Diaphragm Bellofram 1 5 12470 Screw,#10-24 x 1-1/4" Long Steel, Zinc Coated 3 6 -- Cover Brass UNS-C84400 1 7 -- Spacer Brass UNS-C84400 1 8 04736A Piston Polycarbonate 1 --Replacement part is not available. Sub-Assemblies 1-8 15461 Replacement Model A-1 Differential Valve 3-5, 8 15763 Maintenance Kit January 6, 2012 Dry 138k R TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 21i (SSlnnl I MI II 88 II Ii I 'I /1 ®i r , ;/Im:D1 :=�InI'I*. A �milim�- 1 ■ (7 Air 'I� � �imir/I � ,,,,„,,...r.„,..., -. b Lam. ! �■ ������T=TTO Wild = \--1\ ._. —- — f — rr AII 36 7 (926nn] — -- >— =.4 i� = _. i 1 I ii ,_, i 1776 (443nn] _ Ilillir =] ■�■ ■ .IIS Il .lL il) I fT1-1 0 vii 1 Num - I o 7 (I 8mm] IIM9 lei<> - = Co 1 o) E R !Mk11 O — 1 . / MINT !1 L ptil �1' li m AIM O �.� i 1012 (275nn1 94 (235nn] 1-0—I011 (268nn) i 1186nn1—.7 - 2641 (667nn] Figure 10 - Installation Dimensions January 6, 2012 Dry 138i NIKINGR, TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com A. Removing the Cover from the Body 1. Remove the 6" grooved coupling from the top of the dry valve. 2. Remove the section of pipe directly above the dry valve, if provided. 3. Open both of the 1/2" unions on the air supply line. 4. Remove the 2" coupling below the main drain, if provided. 5. Remove the 16 cover screws. 6. The cover and trim that is still connected may now be removed from the valve body. (It may be necessary to pry the valve open as the diaphragm may bond itself to the cover and body over time.) B. Removing/ Replacing the Check Diaphragm 1. The check diaphragm may be lifted from the valve body. 2. If necessary, replace the check diaphragm. C. Inspecting the Prime Chamber and Coupling for Leaks If desired, it is possible to set the G-6000 Dry Pipe Valve and inspect for leaks with the cover removed. 1. Remove the Model A-1 Differential Valve from the prime line and temporarily install a pipe plug. 2. Slowly open the prime valve. Confirm that the valve is primed by reading the prime pressure gauge. 3. With prime water established, partially open the main water supply control valve. 4. Visually inspect the inside of the dry pipe valve for leaks. 5. Close the main water supply control valve. D. Removing / Replacing the Prime Coupling 1. Using a wrench on the flats of the coupling, remove the coupling from the valve body. 2. Inspect the coupling and 0-rings. Replace if necessary, using the instructions in 0-Ring Replacement Bulletin F_120611. E. Removing I Replacing the Prime Chamber Assembly 1. The prime chamber assembly is now held in place by two flanges on the outside diameter of the assembly. Slide the prime chamber assembly toward the prime line and remove from the body. 2. Inspect and replace if necessary. 3. Inspect the seat. The seat should be clean and free of foreign material. If the seat is damaged, the G-6000 Dry Pipe Valve must be replaced. F. Re-Assembling the Valve 1. Verify that the prime piston is fully extended downward. 2. Place the prime chamber assembly in the valve body. Make sure the two flanges are positioned in the groove. 3. Thread the prime coupling into the valve body. Make sure the end of the prime coupling is inserted into the prime chamber assembly. 4. Lay the check diaphragm into the valve body. 5. Position the cover onto the valve body, and install and tighten the cover screws. 6. Re-install any trim that was removed. 7. Place the valve in service by following the steps in Section 4.G. 7. AVAILABILITY The Viking Model G-6000 Dry Valve Riser Assembly is available through a network of domestic and international distributors. See the Viking Corp. Web site for closest distributor or contact The Viking Corporation. January 6, 2012 Dry 138g NIEK1NG® TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 2. Verify that the intermediate chamber of the dry valve is free of water. No water should flow from the drip check when the plunger is pushed. 3. Verify that there is no air coming out of the 1/2" outlet of the PORV. 4. If equipped with a Viking Model E-1 Accelerator: a. Check the air pressure gauge located on the top of the accelerator.Air pressure in the upper chamber of the accelerator should equal the pneumatic pressure maintained in the system. 5. Verify that the water supply main control valve is open and all trim valves are in their normal operating position. 6. Check for signs of mechanical damage and/or corrosive activity. If detected, perform maintenance as required or, if necessary, replace the device. 7. Verify that dry valve and trim are adequately heated and protected from freezing and physical damage. II. TESTS Quarterly Tests A. Water Flow Alarm Test Quarterly testing of water flow alarms is recommended and may be required by the Authority Having Jurisdiction. 1. Notify the Authority Having Jurisdiction and those in the area affected by the test. 2. To test the local electric alarm (if provided) and/or mechanical water motor gong (if provided), OPEN the alarm test valve in the dry valve trim. a. Electric alarm pressure switches should activate. b. Electric local alarms should be audible. c. The local water motor gong should be audible. d. Verify that remote station alarm signals (if provided) were received. 3. When testing is complete, close the alarm test valve. 4. Verify: a. All local alarms stop sounding and alarm panels (if provided) reset. b. All remote station alarms reset. c. All supply piping to water motor properly drains. 5. Verify that the alarm test valve is CLOSED. 6. Verify that the intermediate chamber of the dry valve is free of water. No water should flow from the drip check when the plunger is pushed. 7. Notify the Authority Having Jurisdiction and those in the affected area that testing is complete. B. Main Drain Test Quarterly performance of the Main Drain Test is recommended and may be required by Authorities Having Jurisdiction to verify integrity of the water supply. 1. Notify the Authority Having Jurisdiction and those in the area affected by the test. 2. Record pressure reading from the water supply pressure gauge. 3. Verify that the intermediate chamber of the dry valve is free of water. No water should flow from the drip check when the plunger is pushed. 4. Verify that there is no air coming out of the 1/2" outlet of the PORV. 5. Verify that the dry pipe system is pressurized at or above the minimum pressure recommended in Table 2 for the water supply pressure available. 6. Fully OPEN the main drain valve located on the base of the dry valve. 7. When a full flow is developed from the main drain, record the residual pressure from the water supply pressure gauge. 8. When the test is complete, SLOWLY CLOSE the main drain. 9. Compare test results with previous flow information. If deterioration of the water supply is detected, take appropriate steps to restore adequate water supply. 10.Verify that normal water supply pressure and system pneumatic pressure have been restored, and that all alarm devices and valves are secured in normal operating position. 11. Notify the Authority Having Jurisdiction that the test is complete. Record and/or provide notification of test results as required by the Authority Having Jurisdiction. C. Low Air Alarm Test Quarterly testing of low air alarms is recommended. 1. Notify the Authority Having Jurisdiction and those in the area affected by the test. 2. Close the water supply main control valve supplying the dry valve. 3. Close the priming valve. 4. Open the flow test valve (located on the inlet of the dry valve). January 6, 2012 Dry 138e TECHNICAL DATA 6" MODEL G-6000 DRY VALVE NIIKING® RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 7. Establish air pressure on the system. 8. When air pressure has been established, open the priming valve. Prime water pressure will enter and expand the valve's internal diaphragm assembly onto the valve seat, effectively closing the valve. Verify prime pressure has been established on the prime pressure gauge. 9. Verify that no water flows from the drip check when the plunger is pushed. 10.When the priming pressure has been verified as being established, slowly open the water supply control valve (not shown). 11. When flow is developed from the flow test valve, CLOSE the flow test valve. 12.Fully open the water supply main control valve. 13.Secure all valves in their normal operating position. 14. Notify Authorities Having Jurisdiction and those in the affected area that the system is in service. 15.The system is now fully operational. H. Operational Test: An operational test shall be performed on the system in accordance with NFPA 13 as follows: 1. Open the inspector's test connection. 2. Record the time to trip the valve. 3. Record the time for water delivery to the inspector's test connection. 5. OPERATION A. In the Set Position: When air pressure is introduced into the sprinkler piping, the sensing end of the differential valve is pressurized. This closes the differential valve, preventing prime water from escaping the prime chamber of the dry pipe valve. When prime water enters the prime chamber, the rolling diaphragm is pressurized, causing it to expand downward onto the water seat. c INI Water 40 Air i ,..� iii- . ; �1,'M r I _,_ I milm...; .. ..... ----1 101 t - .4 ..,,,, ,- *IN- -.0 111...............4‘ -— i.• <11/ `J1` / -_ o iii.,,,,;, _ r =ry`<tr�i - �`L�= - a��- �`,( ) _ —r ,, dig;;!_ __ 1111hiMliNall. a" —.14"." "----71--. i lo ` m$ ` IIIA ,, ■I. tg. 1„.....„ 4/ 1..vorgi up- (V"All1101.‘ ))40.4... t�� - �7i f�i ' ,c. 1 waft III t I . 11- virt-wrir 4fl.AP '%10111V' Millb40 11 tatill Figure 6 - Set Position January 6,2012 Dry 138c H(lI1Gi TECHNICAL DATA 6" MODEL G-6000 DRY VALVE RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Air Pressure LIM- Figure 1 - Trim Components Supervisory Switch Al* Air Pressure _IIIIM Prime Pressure �' Gauge and Valve f Gauge & Valve Air ,I/� %� Air Pressure Pressure \7l�' '•�� Valve Supervisory dip Gauge & Optional 1�j1 ^` Check ` Air Supply Switch;�OP `�;� � Valve Accelerator 'l4/1 Connection ,:i `, " Connection '/,jw l*��l \( ��' �• ��� �AN:, �, f���� `� Model A-1 `r�w 0 ����l. Check I PORV k _ ���' �_' Differential Valve �C I/1``}1 Pres10 Alarm $JPressureGoue. /Pressure ft, a4�� �✓_••/' ��..3 and Valve Optional =--��i^�7� J` , Accelerator PORV \�� ���� \�� �`r Check Connection (- Check �, i�•�\ , Valve `;+� ��� ,iValve 4111 41, th `a ' Check �''!W� 1, 1,.- \im/1) 1101•01�1) Flow �11 � Restriction �(('�` \�`��� Test Supply Pressure Itieri tig � (' 'A 1��;(irl1r_ �\\`� \no , Valve Gauge & Valve �: �� !\�//IGS ��� �f�rr�•71r �,a i 't !0 d(r \�/• Flow Test ��CjA, I ��(11 �� u p 41"1-1111 1 Check 'fr� !��� Main Water Supply Valve .� Valve ' Supply _../ Drain Control Valve P� Alarm Water Supply PressureUe I Pressure Control Valve g Switch Valve ' Air Maintenance � Riser Device with n■ Mounted Air Bypass Trim 444 Ili Compressor io ;:,� ib '� Check Valve _0 vol (Soft Seat) '�' Electrical `. • Inlet AirI Air ill Air Supervisory ...,„"ii;' 1� Supervisory Outlet Switch -) Switch V r �� prp 1(-- ��`�� Wnterflow ����wl*�� Waterflow _lo ���► �, Pressure .:1( � >► ��fi:` �j • Pressure �. , Switch Switch 0 IF* ,v4140, O s�1 �,�����J7 • � i--,--_-_-_-_,-7,,,A, #4*.....4-___1_5*-;:4- Np �� \��� Tank Mounted _ ail .),,.., ,,.„,,,y.' ' Air Compressor 1r ���I V 4 qk tpe l� ii IVes1 111110A1 4:; Vi, to.Jove' ri. Igo tp.priteri/i-e. V `41 fill, rellIr" r kiliii4W 41110/V/ 1161-4 II.4i Figure 2 -Air Supply Options January 6, 2012 Dry 138a TECHNICAL DATA 6" MODEL G-6000 DRY VALVE NIKING® RISER ASSEMBLY The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking 6" Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry arf sprinkler piping, which is pressurized with air. The pilot operated valve combines an ,e 1 internal diaphragm assembly that is pressurized closed with priming water, an internal 4L-if � check valve to isolate the sprinkler system piping,and the Model A-1 Differential Valve �. located on the valve trim that allows the valve to operate upon loss of air pressure.The �;, `fit 1 ; differential design of the differential valve allows an air supply of moderate pressure to +, .11 control a higher water supply pressure. When the air pressure in the dry pipe system )10 is reduced sufficiently upon the differential valve due to a sprinkler head operation to �c� ' ,' destroythepressure differential, the differential valve will open and relieve the prim- .1V1,psi. •�%„ i�O� , ing pressure from the internal diaphragm assembly.The internal diaphragm assembly r�w��:f �� •� .11/ will compress, which will allow water to pass through the body of the valve and center •,_ y;�'i,;��ir—:( �1. lerf•-:.dm. r' of the internal check valve, entering the sprinkler system piping. The Viking Model X01 4g:✓ ��-� G-6000 Valve is designed to be used with a water flow pressure switch and/or water 4110 f��J�� 1 ..!� motor gong. For systems that require an accelerator to increase the speed of water delivery, the Viking Model E-1 Accelerator shall be used. �... 2. LISTING AND APPROVALS cOus cULus Listed: VPZV " FM Approved: Dry Pipe Valves 3. TECHNICAL DATA Specifications: Pressure Rating: 250 PSI (17.2 bar) Water Working Pressure Factory Hydrostatically Tested to: 500 PSI (34.5 bar) Air to water differential:Approximately 5.75 to 1 Friction Loss(Given in feet of Schedule 40 pipe based on Hazen &Williams formula C = 120): G-6000 Valve: 44.88' 12" Section of Pipe: 1' Q= Flow Water Supply Control Valve: 14.7' Model G-6000P Valve Cv Factor: 811 AF Cv= Flow Factor(GPM/1 PSI AP) Valve Color Black Q = CV s :AP= Pressure Loss through Valve Material Specifications: S= Specific Gravity of Fluid Refer to Figure 11. Ordering Information: Available since 2011. Part Number: G-6000 Dry Valve Riser Assembly(See Figure 8) - 17048-1 Accessories: Viking Technical Data may be found on Model E 1 Accelerator: 08055 The Viking Corporation's Web site at http:Nwww.vikinggroupinc.com. Drain Manifold: 17056(See Figure 9.) The Web site may include a more recent Model LD-1 Anti-Column Device: 14800 edition of this Technical Data Page. 4. INSTALLATION: A. General Installation Instructions 1. For proper operation and approval, the valve must be installed in the vertical position as trimmed from the factory. DO NOT install horizontally or modify the factory assembled trim except as described in this technical data page. 2. Viking recommends installing a 12" section of pipe directly above the G-6000 Dry Valve. Prior to valve maintenance, this sec- tion of pipe may be removed to provide clearance for lifting the cover from the body. 3. The dry valve must be installed in an area not subject to freezing temperatures or physical damage. If required, provide a valve house (enclosure)with adequate heat around the dry valve and trim. Freezing temperatures and/or excessive pressure will damage the dry valve. When corrosive atmospheres and/or contaminated water supplies are present, it is the owner's responsibility to verify compatibility with the Model G-6000 Dry Valve and associated equipment. 4. The Viking Model E-1 Accelerator should be installed at the location indicated in Figure 1 when required by the installation standard or local Authority Having Jurisdiction. Replaces page 138a-m, dated June 1, 2011. (Revised Form No. F_022111 the replacement parts list and Figure 11.) Model 1O1IA APAN Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve • TEST 12 ORIFICE PUSH LL 0 SjjNMOjOI1 Sizes: . 3A" 1" 11/a" 11/2" 2" The AGF Model 1011A TESTANDRAIN® provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief(NFPA 13 and NFPA 13R).The Model 1011A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011A is available in a full range of sizes (3/" to 2") with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UUFM)features a flushing handle and a 175 PSI factory rating (other pressure ratings available). • Complies with NFPA 13 and NFPA 13R Requirements • Compact, Single-Handle Ball Valve • Tamper-Resistant Test Orifice and Sight Glasses • 300 PSI rated. • Specifiable orifice sizes: 3/8" (2.8K), 7/16" (4.2K), 1/2" (5.6K), 17/32" (8.0K), $/8" (11.2K, ELO), 3A (14.0K, ESFR), and K25 • Relieves Excess System Pressure caused by Surges or Temperature Changes • Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing • Locking Kit Available Repair kits are available for all TESTANDRAlle valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer(1). Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90%and 105%of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for maintenance.Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Reliability, Versatility, Code Compatibility SS-Mt011A_V001 06/13 TESTANDRAIN•is a registered trademark of AGF Manufacturing Inc. Check Valve 803d April 13, 2012 NIKING® TECHNICAL DATA SWING CHECK VALVE MODEL D-1 & G-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com B C 1I 1 SIZE A B C D E F Gs* �4 \' ® IE 2-1/2" 9" 4-1/2" 2-5/8" 2" 2" Flg-Fig ♦ ictf Ail ___-_(_ (65mm) (228,6) (114,3) (66,7) (50,8) (50,8) Not Available ® O 11♦1 �`I`I;lo 3" 10-1/8"4-13/16"2-11/16"2-9/32"2-9/32" Flg—Fig ♦ (80mm) (257) (122,2) (68,3) (58.1) (58.1) Not Available 1♦' FLOW , O 4" 10-5/8" 5-3/16" 3-1/8" 2-1/4" 2-1/4" 9" 15/16" 11 ; (100mm) (269,9) (131,8) (79.4) (57.2) (57,2) (228,6) (23,81) .�1_ Props ° O 6" 13-3/8"6-13/16" 4-1/16" 2-1/4" 2-1/4" 11" 1" �� Sealin Washer = . location �1 A (150mm) (340) (173,3) (103.2) (57,2) (57,2) (279,4) (25,4) 1$ all valva O 8" 17" 8-13/16" 5" 2-1/2" 2-7/8" 13-1/2" 1-1/8" j� „0�.w �;����J, ® (200mm) (431,8) (223,4) (127) (63,4) (73,0) (342,9) (28,58) 00 'r . .�� ��� 0 Dimensions shown in parentheses are millimeters. 0 ���1 rIIIt II -_-____ " 4", 6", and 8" valves are manufactured with sculptured flanges. %17�+\ems` O T Dimension indicates thickness of flange at bolt holes. 2 G** ! ) Figure 1 F* - PART NUMBER ITEM D-1 G-1 G-1 G-1 G-1NO.REQ'D DESCRIPTION MATERIAL NO. 2-1/2" 3" 4" 6" 8" (DN65) (DN80) (DN100) (DN150) (DN200) 2-1/2" 3" 4" 6" 8" 1 Body Ductile Iron,ASTM A536 1 1 1 1 1 (65-45-12) 2 -- -- -- -- -- Cover Assembly,300 PSI WWP E-Coated HSLA Steel,A715 and 1 1 1 1 1 Stainless Steel, UNS-S30400 3 07576 07576 07576 07576 None Bushing Lubricomp 189 Ryton 2 2 2 2 0 4 05355A 05355A 04900A 04991A 05334A Clapper Hinge Pin Stainless Steel, UNS-S30400 1 1 1 1 1 5 05445A 05445A 05445A 05445A 05369A Hinge Pin Retaining Ring Stainless Steel, UNS-S15700 2 2 2 2 2 6 0jjjjA08i508i59L ..'F Clapper Hex Jam Nut#10-24 UNC Stainless Steel, UNS-S30400 1 0 0 0 0 9 Clapper Hex Jam Nut 3/8"-24 UNF Stainless Steel,UNS-S30400 0 1 1 0 0 08144 08144 Clapper Hex Jam Nut Y2'-20 UNC Stainless Steel, UNS-S30400 0 0 0 1 1 7 06595A 08158 08158 08143 08143 Sealing Washer EPDM and Stainless Steel 1 1 1 1 1 letIonr6 8 * * * * * Clapper G1018p oated HR Steel UNS- 1 1 1 1 1 9 * * * * Clapper Rubber EPDM,ASTM D2000 1 1 1 1 1 10 * * * Clapper Rubber Retainer Stainless Steel, UNS-S30400 1 1 1 1 1 06595A H.H.C. Screw#10-24 UNC x 1/2"(12.7 mm)Ig. Stainless Steel, UNS-S30400 1 0 0 0 0 10194 10194 Screw, Button Head, Socket. 3/8"-24 UNF x 1/2" Stainless Steel, UNS-S30400 0 1 1 0 0 11 10308 Screw, Button Head, Socket, 1/2" 20 UNF x 3/4" Stainless Steel, UNS-S30400 0 0 0 1 1 (19.1 mm)lg. 10686 Screw, Button Head, Socket, 1/2"-20 UNF x 7/8" Stainless Steel, UNS-S30400 0 0 0 0 1 12 -- -- -- -- -- Seat Brass, UNS-C84400 1 1 1 1 1 13 05354B 05354B 04649B 04992B 05339C Cover Gasket EPDM,ASTM D2000 1 1 1 1 1 01517A 01517A 01517A,,4,4,„„,,,„.,.. H.H.C. Screw 3/8"-16 UNC x 3/4"(19,1 mm)Ig. Steel,Zinc Plated 4 4 6 0 0 14 `04993A H.H.C. Screw '/2'-13 UNC x 7/8"(22.2 mm)Ig. Steel,Zinc Plated 0 0 0 6 0 01922A H.H.C. Screw 5/8"-11 UNC x 1-1/4"(31.8 mm)Ig. Steel,Zinc Plated 0 0 0 0 6 _ -- 1/2"(15 mm) NPT Pipe Plug Steel 2 2 2 0 0 15 i 3/4"(20 mm)NPT Pipe Plug Steel 0 0 0 2 2 --Indicates replacement part is not available Indicates replacement part only available in a Sub-Assembly listed below Sub-Assemblies 3.6-11 05499B 08518 08519 08520 08521 Clapper Assembly 9,10 -- 14864 14865 14866 -- Replacement Clapper Rubber Kit* 'Clapper rubbers are different on 3',4',8 6"G-1 valve than original manufacture.If clapper rubber requires replacement,order replacement rubber kit Replaces page 803a-d, dated July 1, 2011. Form No. F_102688 (Revised Figure 1) Check Valve 803b April 13, 2012 TECHNICAL DATA SWING CHECK VALVE MODEL D-1 & G-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. INSTALLATION The Swing Check Valve must be installed in an area not subject to physical damage.When corrosive atmospheres and/or contami- nated water supplies are present, it is the owner's responsibility to verify compatibility with the Swing Check Valve and associated equipment. Prior to installing the valve, thoroughly flush the water supply piping to verify that no foreign matter is present. The Swing Check Valve may be installed in the vertical position with direction of flow up, or in the horizontal position with the access cover up. Systems with water working pressures above 175 psi (12 bar) may require extra-heavy pattern fittings. Viking Swing Check Valve flanges are Ductile Iron ANSI B16.42, Class 150, with a maximum water working pressure of 300 psi (20.7 bar). ANSI B16.42, Class 150 flanges are not compatible with ANSI Class 250 or Class 300 flanges.To mate the Viking Swing Check Valve with ANSI Class 250 or Class 300 flanges, use the grooved-inlet/grooved-outlet style installed with listed grooved/flanged adapters of the appropriate pressure rating. For piping with grooved connections, the grooved-inlet/grooved-outlet style Swing Check Valve may be installed with listed grooved couplings of the appropriate pressure rating. 5. OPERATION (Refer to Figure 1) Flow through the Viking Swing Check Valve lifts the rubber-gasketed clapper(8, and 9) off the seat(12) to enter the sprinkler pip- ing. When flow through the valve stops, the clapper(8) closes quickly. The rubber gasket (9) forms a tight seal against the brass water seat (12), trapping pressure above the clapper and preventing reverse flow from sprinkler piping. Hydrostatic Test: The Swing Check Valve is manufactured and listed for use at a maximum water working pressure of 300 psi (20.7 bar).The valve is factory tested at 600 psi (41.4 bar). Check Valves may be hydrostatically tested (in accordance with NFPA 13) at 350 psi (24.1 bar) and/or 50 psi (3.4 bar) above the normal water working pressure for limited periods of time(two hours) for the purpose of ac- ceptance by the Authority Having Jurisdiction. If air testing is required, do not exceed 40 psi (2.8 bar) air pressure. 6. INSPECTIONS, TESTS AND MAINTENANCE NOTICE: The owner is responsible for maintaining the fire-protection system and devices in proper operating condition. The Viking Swing Check Valve must be kept free of foreign matter, freezing conditions (when used on wet systems), corrosive atmospheres, contaminated water supplies, and any condition that could impair its operation or damage the device. It is imperative that the system be inspected and tested on a regular basis. The frequency of the inspections may vary due to contaminated water supplies, corrosive water supplies, and corrosive atmospheres. For minimum maintenance and inspection requirements, refer to NFPA 25. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and in- spection requirements that must be followed. WARNING: Any system maintenance which involves placing a control valve or detection system out of serv- ice may eliminate the fire-protection capabilities of that system. Prior to proceeding, notify all the Authority Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected areas. 6-A. Five-Year Internal Inspection Internal inspection of Swing Check Valves is recommended every five years unless inspections and tests indicate more fre- quent inspections are required. (Refer to Figure 1) 1. Notify the Authority Having Jurisdiction, remote station alarm monitors, and those in the area affected that the system will be taken out of service. Consideration should be given to employment of a fire patrol in the affected areas. 2. Close the water supply main control valve, placing the system out of service. 3. Open the main drain. If necessary, open the system test valve to vent and completely drain the system. 4. Use the appropriate wrench to loosen and remove the cover screws (14), and remove the cover/clapper assembly (2-11). 5. Inspect the water seat (12). Wipe away all contaminants, dirt, and mineral deposits. DO NOT use solvents or abrasives. 6. Inspect the cover/clapper assembly (2-11) and the cover gasket (13). Test the hinged clapper (8) for freedom of move- ment. Renew or replace damaged or worn parts as required. CAUTION: Never apply any lubricant to seats, gaskets, or any internal operating parts of the valve. Petroleum- based grease or oil will damage rubber components and may prevent proper operation. 7. When Internal inspection of the Check Valve is complete, perform step 6 of paragraph 11. VALVE MAINTENANCE to re- install the cover/clapper assembly (2-11). THIS PAGE INTENTIONALLY LEFT BLANK Replaces page 815a-g, dated May 31, 2012. Form No. F_011189 (Added Table 3,Trim Package Part Numbers.) Check Valve 815f May 9, 2013 NEKING® EASY RISER® SWING TECHNICAL DATA CHECK VALVE MODELS E-1 & F-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com For ESFR Cold Storage Systems, use Preprimed Preaction Trim and Bypass and Drain Trim. See page 48a-d for trim arrangements. Water ; Gauge 1/4 Plu g Gauge ` Water J Water / Gauge l/ ,i/r` /'•• 1/4 x 4 1/4 Plug o loci /�/ (101,6) 1/4 Plug "" ` } Side Outlet /�j• ICO) ///o t' i'is Globe Valve " 1/4 x 4 'y� /i/ �*:'� / Side Outlet Slue ��i%'' /// (101,6) Globe Valve 1/4 `//i �� Outlet Globe Valve `//i• (101,6) \, 3' l�j�' , dl)J�1 1-1/4 X 4-1/2 (114,3) /���`�� % 4',6'.8" Watert ,,�. *2 X 4 (101,6) Gaug � p , [. Illllr � -;#1/4x4 O �l 01,6)11 O O reAI . r& 1 �( pot is �� 1-1/4 X 4-1/2 O 3. 1/4 Pu 9 Side Outlet II ,,� , 6.- (114,3) 1-1/4"x 90 Ell t� Globe Valve 116 Ai. ��,-/ c 24•x690• 111.0 Ell 3' 1-1/4x2 J 1-1/4" x 90 El (50,8) 4",6",8" 2 x 2-1/2 ) 1-1/4 x 2 4" (63.5) (50,8) %II-110C� 3- 1_1/4• `1 1-1/4 Ball Valve 1/ Ball Valve 4",6",8" �� (Normally I11� 2' Ball Valve i Closed) �W„._.e„0..0, ; (Normally ��/ ikto Closed) / r4,.... TO DRAIN TO DRAIN 2-1/2" MODEL E-1 3",4",6", & 8' MODEL F-1 EASY RISER CHECK VALVE EASY RISER CHECK VALVE TRIM CHART Figure 2 TRIM CHART Note 1: 300 psi (20.7 bar) water pressure gauges are provided with trim. 600 psi (41.4 bar)water pressure gauges are avail- able. Order separately when needed*. Refer to Viking's current price schedule. "NFPA 13 requires gauges to have a minimum limit not less than twice the normal water working pressure at the point where the gauges are installed.When normal water working pressure exceeds 150 psi(10.3 bar).order 600 psi(41.4 bar)water pressure gauges separately. Note 2: System Drain Ball Valve is UL Listed and FM Approved for 300 psi (20.7 bar)water working pressure. Check Valve 815d May 9, 2013 EASY RISER® SWING NIICING® TECHNICAL DATA CHECK VALVE MODELS E-1 & F-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5. Reinstall the cover and clapper assembly (2-11) into the valve: i. Line up the clapper rubber(9)with the water seat(12). Ensure the clapper rubber retainer(10)fits inside the seat of the valve (pull back slightly and there should be some resistance). ii. Line up the holes of the cover (2) and cover gasket (13)with the valve body (1) and replace the cover screws (14) using a Socket Wrench with a 9/16" socket. 7. AVAILABILITY The Viking Easy Riser~Swing Check Valve is available through a network of domestic and international distributors. See the Viking Corp. Web site for closest distributor or contact The Viking Corporation. 8. GUARANTEES For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Table 1 -Valve Part Numbers and Specifications Table 2 -Torque Values for Part Shipping Easy Riser Swing Check DescriptionI Nom! Number Friction Loss' Weight Valve Cover Screws Flange/Flange Valve Screw Torque Flange Drilling Model F-1 Size Size Value ANSI 3" _- 08505 10 ft. (3.1m) 35 lbs. (16 kg) ANSI 4" 08508 13 ft. (4.0 m) 27 lbs. (12 kg) 2-1/2" 3/8"-16 19 ft-lb ANSI 6" 08511 20 ft. (6.0 m) 75 lbs. (34 kg) (DN65) H.H.C. (2.63 kg-m) ANSI/Japan DN100 1 09039 13 ft. (4.0 m) 27 lbs. (12 kg) 3" 3/8"-16 19 ft-lb ANSI/Japan DN150 09385 20 ft. (6.0 m) 75 lbs. (34 kg) (DN80) H.H.C. (2.63 kg-m) ANSI/Japan DN200 14023 23 ft.(7.0 m) 119 lbs. (54 kg) 4" 3/8"-16 19 ft-lb PN10/15 DN80 08796 10 ft. (3.1m) 35 lbs. (16 kg) (DN100) H.H.C. (2.63 kg-m) PN1C.15' DN100 08797 13 ft. (4.0 m) 27 lbs. (12 kg) PN10/16 DN150 08835 20 ft. (6.0 m) 75 lbs. (34 kg) 6" W-13 45 ft-lb PN10 DN200 08836 23 ft. (7.0 m) 119 lbs. (54 kg) (DN150) H.H.C. (6.23 kg-m) PN16 DN200 12355 23 ft. (7.0 m) 119 lbs. (54 kg) 8" 5/8"-11 93 ft-lb (DN200) H.H C. (12.9 kg-m) Flange/Groove Flange Drilling/Pi.: , Model F-1 0.D..°` ANSI/89mm ' 3" 08506 10 ft. (3.1m) 27 lbs. (12 kg) Table 3 -Trim Package Part ANSI/114mm 4" 08509 13 ft. (4.0 m) 37 lbs. (17 kg) Numbers ANSI/168mm . 6" 08512 20 ft. (6.0 m) 64 lbs. (29 kg) Valve ANSI/219m is 8" 08515 23 ft. (7.0 m) 119 lbs. (54 kg) Size Part Number PN10/16/89mm DN80 12648 10 ft. (3.1m) 27 lbs. (12 kg) PN10/16/ 114mm DN100 1 12649 13 ft.(4.0 m) 37 lbs. (17 kg) Wet System Trim Packages PN10/16/165mm,;.j DN150 12652 20 ft. (6.0 m) 64 lbs. (29 kg) 2-1/2", 3"(DN65), 07236 PN10/16/168mm DN150 08512 20 ft. (6.0 m) 64 lbs. (29 kg) (DN80) PN10/219mm, DN200 12651 23 ft. (7.0 m) 119 lbs. (54 kg) PN16/219mm DN200 12650 23 ft. (7.0 m) 119 lbs. (54 kg) (DN100), (DN150), 07237 (DN200) Groove/Groove Preaction System Trim Packages Pipe O.D.,a Model E-1 2-1/2"(DN65) 13776 73mm 2%'/DN65 07929 6 ft. (1.8m) 16 lbs. (7kg) Model F-1 89mm `' 3"/DN80 ' 08507 10 ft. (3.1m) 20 lbs. (9 kg) (DN80), (DN100), 13777 114mm y'' 4" /DN100 08510 13 ft. (4.0 m) 27 lbs. (12 kg) (DN150), (DN200) 165mm 'I DN150 12356 20 ft. (6.0 m) 51 lbs. (23 kg) 168mm:.__ 6")DN150 : 08513 20 ft. (6.0 m) 51 lbs. (23 kg) 219mm " 08516 23 ft. (7.0 m) 106 lbs. (48 kg) 'Expressed in equivalent length of Schedule 40 pipe based on Hazen&Williams formula:C=120. Check Valve 815b May 9, 2013 N1K1NG® EASY RISER® SWING TECHNICAL DATA CHECK VALVE MODELS E-1 & F-1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com • System is designed so maximum operating pressures of the system does not exceed 175 PSI (12 bar). • Refer to technical data page 47a-c: Automatic Pressure Control System Material Standards: Refer to Figure 1. Ordering Information: See Table 1 for part numbers and shipping weights. 4. INSTALLATION FOR THE VIKING ESFR COLD STORAGE SYSTEM, REFER TO DATA PAGE 45a-j FOR INSTRUCTIONS ON PLACING THE SYSTEM IN SERVICE. The Easy Riser'Swing Check Valve must be installed in an area not subject to freezing temperatures or physical damage. When corrosive atmospheres and/or contaminated water supplies are present, it is the owner's responsibility to verify compatibility with the Easy Riser" Swing Check Valve, trim, and associated equipment. Prior to installing the valve, thoroughly flush the water supply piping to verify that no foreign matter is present. The Easy Riser Swing Check Valve may be installed in the vertical position with direction of flow up, or in the horizontal position with the access cover up. 1. Remove all plastic thread protectors from the openings of the Easy Risers Swing Check Valve. 2.Apply a small amount of pipe-joint compound or tape to the external threads of all pipe connections required. Take care not to allow any compound, tape, or other foreign matter inside any of the nipples or openings of the valve or trim components. 3. Easy Riser Swing Check Valve Trim Charts are provided with Trim Packages and in the Viking Engineering and Design Data book. 4. Verify that all system components are rated for the water working pressure of the system. Hydrostatic Test: The Easy Riser' Swing Check Valve is manufactured and listed for use at a maximum water working pressure of 300 psi (20.7 bar). The valve is factory tested at 600 psi (41.4 bar). Easy Riser' Swing Check Valves may be hydrostatically tested at 350 psi (24.1 bar) and/or 50 psi (3.5 bar) above the normal water working pressure for limited periods of time (two hours) for the purpose of acceptance by the Authority Having Jurisdiction. If air testing is required, DO NOT exceed 40 psi (2.8 bar) air pressure. 5. OPERATION (Refer to Figure 1.) Water flowing through the Viking Easy Riser' Swing Check Valve lifts the rubber-gasketed clapper(8 and 9) off the seat (12) and flows into the sprinkler piping. When flow through the valve stops, the clapper (8) closes quickly. The rubber gasket (9) forms a tight seal against the brass water seat (12), trapping pressurized water above the clapper and preventing reverse flow from the sprinkler piping. 6. INSPECTIONS, TESTS, AND MAINTENANCE FOR THE VIKING ESFR COLD STORAGE SYSTEM, REFER TO DATA PAGE 45 a-j FOR INSPECTIONS AND TESTS NOTICE: THE OWNER IS RESPONSIBLE FOR MAINTAINING THE FIRE-PROTECTION SYSTEM AND DEVICES IN PROPER OPERATING CONDITION. The Viking Easy Riser Swing Check Valve and trim must be kept free of foreign matter, freezing conditions, corrosive atmos- pheres, contaminated water supplies, and any condition that could impair its operation or damage the device. It is imperative that the system be inspected and tested on a regular basis. The frequency of the inspections may vary due to contaminated water supplies, corrosive water supplies, and corrosive atmospheres. For minimum maintenance and inspection requirements, refer to NFPA 25. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and in- spection requirements that must be followed. WARNING:ANY SYSTEM MAINTENANCE WHICH INVOLVES PLACING A CONTROL VALVE OR DETECTION SYSTEM OUT OF SERVICE MAY ELIMINATE THE FIRE-PROTECTION CAPABILITIES OF THAT SYSTEM. PRIOR TO PROCEEDING, NO- TIFY ALL THE AUTHORITY HAVING JURISDICTION. CONSIDERATION SHOULD BE GIVEN TO EMPLOYMENT OF A FIRE PATROL IN THE AFFECTED AREAS. 6-A. Five-Year Internal Inspection Internal inspection of check valves is recommended every five years unless inspections and tests indicate more frequent inspections are required. (Refer to Figure 1.) 1. Notify the Authority Having Jurisdiction, remote station alarm monitors, and those in the area affected that the system will be taken out of service. Consideration should be given to employment of a fire patrol in the affected areas. 2. Close the water supply main control valve, placing the system out of service. 3. Open the main drain. If necessary, open the system test valve to vent and completely drain the system. 139A Charles Street #313 Boston, MA 02114 TOLL FREE / 800-463-1276 FAX / 888-502-3775 spi inkflex@gmail.com www.sprinkflex.com —•� FLEXHEAP° � _LV(- UNISTRUT �� I I TUBE&CONDUIT A FC � rNDUS TRIES LA') HeritageP la stics" s� RIdgeIli `�neNISTRUT ��;� Columbia-MBF CO ) Pipe Manufacturing) construction wire,conduit 7TECTRONTUbe SprinkFLEX Ker TECI{ --HI-STRUT 62014 Atkore International.Inc.All rights reserved.SPF-L-9000-1401 FRICTION LOSS DATA UNBRAIDED HOSE UL LISTED UL LISTED- MODEL LET&OUTLET SIZE LENGTH INCH(mm) NUMBER OF 90 UNBRAIDED HOSE MAXIMUM El • T ' NCH DEGREE BENDS LENGTH OF SCH 40 1 INCH D ., ' PIPE(C=120),FT SFN28H 1 x 1/2 28" (700mm) 2 22 SFN28T 1 x 3/4 10mm) 2 28 SFN4OH 1 x 1/2 40" (1000mm 3 39 SFN4OT 1 x3/4 40" (1000mm) < 54 SFN48H 1 x 1/2 48" (1200m 1 3 56 SFN48T 1 x3/4 4:" 00mm) 3 63 SFN59H 1 x 1/2 59" (1500mm) 3 59 SFN59T '4 59" (1500mm) 3 SFN71H 1 x 1/2 71" (1800mm) 3 67 171T 1 x3/4 71" (1800mm) 3 74 'Series SFN models are unbraided/Series SFB models are braided 'Unbraided hoses are UL Listed 'Braided hoses are FM Approved and UL Listed BRAIDED HOSE FM APPROVED AND UL LISTED INLET&OUTLET UL UL-BRAIDED HOSE MAXIMUM FM FM-BRAIDED HOSE SIZE LENGTH INCH NUMBER OF 90 EQUIVALENT LENGTH OF NUMBER OF 90 MAXIMUM EQUIVALENT MODEL NPT INCH (mm) DEGREE BENDS SCH 401 INCH DIAMETER PIPE DEGREE BENDS LENGTH OF SCH 401 INCH (C=120),FT DIAMETER PIPE(C=100),FT SFB28H 1 x 1/2 28" (700mm) 2 22 1 46.4 SFB28T 1 x 3/4 28" (700mm) 2 28 1 39.1 SFB4OH 1 x 1/2 40" (1000mm) 3 39 1 53.9 SFB4OT 1 x 3/4 40" (1000mm) 3 54 1 45.3 SFB48H 1 x 1/2 48" (1200mm) 3 56 2 73.4 SFB48T 1 x 3/4 48" (1200mm) 3 63 2 64.3 SFB59H 1 x 1/2 59" (1500mm) 3 59 3 89.9 SFB59T 1 x 3/4 59" (1500mm) 3 74 3 86.5 SFB71H 1 x1/2 71" (1800mm) 3 67 4 112.8 SFB71T 1 x3/4 71" (1800mm) 3 74 4 104.9 BRAIDED HOSE WITH ELBOW - FM APPROVED UL FM FM-BRAIDED HOSE I MODEL INLET&OUTLET SIZE LENGTH INCH(mm) NUMBER OF 90 NUMBER OF 90 DEGREE BENDS MAXIMUM EQUIVALENT NPT INCH DEGREE BENDS LENGTH OF SCH 40 1 INCH DIAMETER PIPE(C=120),FT SFB28H-E 1 x 1/2 28" (700mm) 2 1 - 48.4 SFB28T-E 1 x3/4 28" (700mm) 2 1 41.1 SFB4OH-E 1 x 1/2 40" (1000mm) 3 1 55.9 SFB4OT-E 1 x3/4 40" (1000mm) 3 1 47.3 SFB48H-E 1 x 1/2 48" (1200mm) 3 2 75.4 SFB48T-E 1 x3/4 48" (1200mm) 3 2 66.3 SFB59H-E 1 x 1/2 59" (1500mm) 3 3 91.9 SFB59T-E 1 x3/4 59" (1500mm) 3 3 88.5 SFB71H-E 1 x 1/2 71" (1800mm) 3 4 114.8 SFB71T-E 1 x3/4 71" (1800mm) 3 4 106.9 r T Series SFN Unbraided flexible Hose Assemblies LISTED Y . - Series SFB Braided Flexible Hose Assemblies IVO. E U)ous APPROVED LISTED SprinkFLEX Stainless Steel Sprinkler Fittings connect the branch line to the sprinkler using a flexible stainless steel hose and reducer. The flexible stainless steel hose and fittings are intended for direct connection to the sprinkler and are particularly suited for use in suspended and hard ceiling applications. Each drop assembly comes with one stainless steel flexible hose, one branch line connection nipple, one sprinkler reducing nipple and bracket system. SYSTEM OPTIONS • Pre-assembled, ready to install, unbraided and braided { flexible stainless steel hose lengths: 28" (700mm), 40" (1000mm), 48" (1200mm), °s 59" (1500mm), 71" (1800mm) • 1/2" and 3/4" outlet fittings for connecting sprinkler 1 • Pre-assembled, ready to install mounting bracket rt available in 24" and 48" long "r" • Mounting bracket allows the sprinkler to be locate anywhere within the ceiling with reference marks in +l` the center for ease of installation without the need for measuring. f • Optional factory installed sprinkler head. ,g TECHNICAL DATA --- -g • Maximum Working Pressure: 200 psi (1375 kPa) • Maximum Ambient Temperature: 300 F (149'0) • Connection to Branch Line: 1-inch NPT • Minimum Bend Radius of Flexible Stainless Steel Hose: 3 inches (76.2 mm) per UL Listing 8 inches (203.2 mm) per FM Approval f / The flexible stainless steel hose should not be bent within 21/2 inches (64 mm) of the connection nut at both ends. • UL Maximum K-Factor of Sprinkler to be connected to a Sprinkler Reducing Nipple: 4 '""' 1/2 inch outlets: 8.0 3/4 inch outlets: 11.2 t `I • FM Maximum K-Factor of Sprinkler to be connected to ,/ Sprinkler Reducing Nipple: , 1/2 inch outlets: 5.6 3/4 inch outlets: 8.0 • Listings and Approvals: Unbraided models are UL Listed Braided models are FM Approved and UL Listed a 2 of 2 NiGso GROOVED COUPLING TECHNICAL DATA MODEL V-7705 STANDARD FLEXIBLE COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. INSTALLATION Be sure that all pipes and fittings used with this coupling are standard sizes and not metric. Refer to the following VGS"Technical Data Sheets for detailed installation instructions: • Grooved Coupling Installation Guide (Form No. F_031114) • Pipe End Preparation Guide (Form No. F_031214) • Rubber Gasket Installation Guide (Form No. F_031014) Table 2: V-Z05 (Rigid) and V-7705 (Flexible) VGS Coupling Gaskets . aximum Tamp. Compound * Color C* • " t Range Green Stripe* Good for cold & hot water up to +230°F(+110°C). Also good for services for water with acid,water with Purple Stripe** chlorine,deionized water,seawater and waste water, -30°F(-34°C) EPDME dilute acids, oil-free air,and many chemicals. to +230°F(+110°C) Green and Purple Not Recommended for petroleum oils. mineral oils Stripe*** solvents, and aromatic hydrocarbons. *Lubricated **Composition Change, Lubricated ***Additional Color Coding, Lubricated Note:Additional Lubricant is not required. 111111111111114 1111111161. 11111111bilk Note: All other gasketed prducts (i.e. reducing coupling, mech tee, etc.) have never been pre-lubricated. These products have always been, and are today, marked with a single green stripe. Refer to the latest edition of the VGS Technical Data Sheets. For additional information contact Viking Technical Services. Table 3: Approved Pipe and End Types Schedule 40, Cut Goove-Schedule 40, Roll Groove-Schedule 30, Cut Goove -Schedule 30, Roll Groove -Allied Tube & Conduit, "XL"-Allied Tube & Conduit, "BLT" -Allied Tube & Conduit, "Dyna-Thread" - Wheatland Tube, "Mega-Thread"- Schedule 10, Roll Groove -Allied Tube & Conduit, "Dyna-Flow" - Bullmoose Tube, "EDDY-Flow" - Bullmoose Tube, "EDDYlite" -Wheatland Tube, "Mega-Flow" Form No. F_021214 16.03.04 Rev 16.1 Replaces form No. F_021214 Rev 15.1 (Reformatting and corrections) t tl V S Product Specifications I Grooved Fittings MODEL V-901 SHORT RADIUS 90° ELBOW C-E-1 C-E -1 MODEL V-903 SHORT RADIUS TEE 1. c �l u s ® i ti -i LISTED APPROVED Nominal Pipe V-901 -:'-{/403 ;`V 903 Size 0.0. SR 90 Elbow SR Straight Tee mm/In mm/in C-E(mm/in) Kgs/Lbs C-E(mm/in) Kgs/Lbs 50 60.3 70 0 7 70 1 0 2 2.375 2.75 1.5 2.75 2.2 65 710 76 0.9 76 11 2.5 2.875 3.00 2.0 3.00 2.9 65 76.1 76 0.9 76 13 80 88.9 86 1.4 86 2.0 3 3.500 3.38 3.1 3.38 4.4 100 114.3 102 1.7 102 3.6 4 4.500 4.00 3.7 4.00 7.9 125 141.3 124 3.5 124 4.6 5 5.563 4.88 7.7 4.88 10.1 150 165.1 140 5.5 140 8.6 150 168.3 140 5.5 140 8.6 6 6.625 5.50 121 5.50 18.9 200 219.1 176 11.0 176 16.5 8 8.625 6.94 24.2 6.94 36.3 NIKING Trusted above aII.TM 19 7 NGs TM Grooved Piping System j Product Catalog ' - tr Y aJc 1 r IS o 4Enh .3 .. • _ fil° Ma `�' /4 .. G • • • .t ///.///////■ tr. _ c. . r f ♦4 r .,w. ArY �' c//C./. > . 41111.•' 1 _' . • • i .r �� y11 �f �A 1 .. 11$1101•111111,1•4-..... •' `. • 41 • •.. . - .. w rt ill dIIP ith 90° ELBOW IM/ Star- Fire Products Division of Anvil'International 0(441:1M)» Ductile Iron Submittal Sheet 90" ELBOW Nominal Anvil Item Universal Max. Dimensions- App rox. Size Number Number Working In.lmml Wtprox. Pressure A B H A—01 as,(k,) 1 840000004 DB90033 500 1.50 1.50 0.62 20 3450 38.10 38.10 0.28 11/4 840000012 DB90044 500 1.75 1.75 0.90 t 32 3450 44.45 44.45 0.41 B 11/2 840000020 0890055 500 1.94 1.94 1.20 AP_ 40 3450 49.276 49.276 0.54 t 2 840000038 DB90066 500 2.25 2.25 1.85 50 3450 57.15 57.15 0.84 MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL & ULC Listed & Dimensions conform to ASME 816.3 Class 150. jj ®© Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME 81.20.1. Ductile ironer ASTM A536 Class 65-45-12. APPROVED p For Listing/Approval NOTICE:Ductile iron finings have higher tensile strength than that of steel pipe.Therefore,over tightening can cause damagerothreads whichcause leakage.Ductile details contact your g g 9 `� pipemayAnvilStarTM Representative. iron Fittings should be tightened three turns beyond hand tight,but no more than four turns. PROJECT INFORMATION: APPROVAL STAMP: Project: Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: Notes 2: SPF Cast&Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule, Z ANVIL REV.03.03.06-0010 go to www.anvilstar.com or contact your local AnvilStar representative .. TABLE OF CONTENTS 1 PIPE & FITTINGS Schedule 10/40 Sprinkler Pipe—ASTM A135 Ductile Iron Threaded Fittings—Anvil Grooved Fittings—Viking VGS Standard Rigid Coupling—Viking VGS Flex Connection- Sprinkflex 2 VALVES Riser Check Valve—Viking Check Valve -Viking Butterfly Valve- Fivalco Inspector's Test Valve—AGF Model 1000 Dry Pipe Valve—Viking G-6000 Preaction Valve—Viking G-2000P 3 SPRINKLER HEADS Sprinkler Heads—Viking 4 HANGERS Loop Hanger Rings—TOLCO Sammys—Horiz&Vert All Thread Rod—TOLCO 5 ELECTRICAL DEVICES Flow Switch—Potter Electric Signal Company VSR-F Alarm Bell—Potter Electric Signal Company PBA1206 Air Compressor-General 6 MISCELLANEOUS Fire Department Connection-Guardian