Loading...
130 OCEAN GATE DR - PERMIT (2) -S y\i']� �' AO°r �. n�s, CITY OF ATLANTIC BEACH -- '+ >. J 800 SEMINOLE ROAD V " ATLANTIC BEACH, FL 32233 x INSPECTION PHONE LINE 247-5814 ..) SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFAT-2357 Job Type: SINGLE FAMILY ATTACHED DWELLING Description: new 2-story single-family attached home Estimated Value: $124,720.00 Issue Date: 11/17/2016 Expiration Date: 5/16/2017 PROPERTY ADDRESS: Address: 130 OCEAN GATE DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Robert J. Peterson, CGC1506666 Address: 2768 STATE RD A1A #701 Phone: 904-334-1202 PERMIT INFORMATION: FEES: ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $277.08 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $554.16 STATE DCA SURCHARGE $8.31 STATE DBPR SURCHARGE $8.31 FINIALEIS +lyi,SIS CQ^vKE T ANCESNWI QI.L CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 3 si, CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j`� .}- ATLANTIC BEACH,FL 32233 i\ INSPECTION PHONE LINE 247-5814 WATER CONNECT/TAP & $185.00 METER Total Payments: $1,232.86 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. �$,,`Lyrjz e A, .e�s� CITY OF ATLANTIC BEACH J S) 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 \4'-;-.140111,..f> SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFAT-2358 Job Type: SINGLE FAMILY ATTACHED DWELLING Description: new 2-story single-family attached home Estimated Value: $124,720.00 Issue Date: 11/17/2016 Expiration Date: 5/16/2017 PROPERTY ADDRESS: Address: 134 OCEAN GATE DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Robert J. Peterson, CGC1506666 Address: 2768 STATE RD A1A#701 Phone: 904-334-1202 PERMIT INFORMATION: FEES: ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $277.08 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $554.16 STATE DCA SURCHARGE $8.31 STATE DBPR SURCHARGE $8.31 iAz IT'IS APP9dWDCO I C ICJ(JI NNCE 9—rg0ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. e AP , CITY OF ATLANTIC BEACH A j 800 SEMINOLE ROAD 1-5',1r x X ATLANTIC BEACH, FL 32233 , INSPECTION PHONE LINE 247-5814 WATER CONNECT/TAP & $185.00 METER Total Payments: $1,232.86 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. r ,mss V. \t, CITY OF ATLANTIC BEACH 5,.:....- 9 800 SEMINOLE ROAD s) j j ATLANTIC BEACH, FL 32233 \ INSPECTION PHONE LINE 247-5814 \J3219r SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFAT-2359 Job Type: SINGLE FAMILY ATTACHED DWELLING Description: new 2-story single-family attached home Estimated Value: $124,720.00 Issue Date: 11/17/2016 Expiration Date: 5/16/2017 PROPERTY ADDRESS: Address: 138 OCEAN GATE DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Robert J. Peterson, CGC1506666 Address: 2768 STATE RD A1A #701 Phone: 904-334-1202 PERMIT INFORMATION: FEES: ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $277.08 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $554.16 STATE DCA SURCHARGE $8.31 STATE DBPR SURCHARGE $8.31 WATER CROSS CONNECTION $50.00 PERMI I IS APPROVED ONLY IN ACCORDANCE \W I I I1 ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH A S 800 SEMINOLE ROAD j t1 ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 WATER CONNECT/TAP & $185.00 METER Total Payments: $1,232.86 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. rAPPLYr �,�1 : City of Atlantic Beach ICATION NUMBER u' , •;,>\ Building Department (To be assigned by the Building Department.) - 800 Seminole Road RU- J rAl Q1 w - Atlantic Beach, Florida 32233-5445, Phone(904)247-5826 • Fax(904)247-5845 /�� ",01119'r- E-mail: building-dept@coab.us Date routed: Id LC1 (110 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 13o &c ut()GOO.- of. De artment review required Ye�s` No Buildi.) Applicant: ZUAA�� c1# OnIlci; i Planning &Zoning> .4\ (� Tree Administrator Project: ��.1A o1^S o(9 Slr\� r().cnl Iy ublic Works CtiV CLUA AUL,t, �o�� Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: .proved. ['Denied. (Circle one.) Comments: BUILDI PLANNING &ZONING ,/y� x'69-427'16 Reviewed by: !� ' � Date: TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH OFFICE COPY 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: # 130 OceanGate Drive, COAB, 32233 Permit Number: Ito—S FAT- a-13--Th Legal Description: 38-2S29E-7.41B De Castro Y Ferrr Grant PT RECD O/R 16531-2248 Parcel #Blk: 4 Lot: 10 Floor Area of Sq.Ft. Sq.Ft Valuation of Work ; i.l 'roposed Work heated/cooled 1172 non-heated/cooled 188=/3 b 0 Class of Work(circle one): r New (X) Addition Alteration Repair Move Demolition /spa window/door Use of existing/proposed structure(s) (circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No(X) N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: Construct attached two story Triplex single family homes Property Owner Information: Name: Beaches Habitat for Humanity Address: 797 Mayport Rd City Atlantic Beach State FL Zip 32233 Phone#904-241-1202 E-Mail or Fax#(Optional)#904-241-4310,rpeterson(ci)beacheshabitat.org Contractor Information: Company Name:201 Mayport Construction Management, LLC Qualifying Agent: Robert Peterson Address: 2768 State Rd.AlA# 701 City Atlantic Beach State FL Zip 32233 Office Phone 904-595-5798 Job Site/Contact Number_904-334-1202 Fax# State Certification/Registration#CGC 1506666 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void f work is not commenced within six(6)months, or if construction or work is suspended or abandoned for aper iod of six(6)months at any time after work is commenced. I understand that separate permits must be secured for ElectricalpWork,Plumbing,Signs, Wells, Pools, Furnaces, Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I herebycertify that ave read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type of ork will be : :plied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other •,eral,state or local law regulating construction or the performance of construction. Signature of OwnerC1 • �'�� Signature of Contractor ' . Pr Print Name 642.19(a-ti. -•2—a Print Name 9.0(7I'v-1- lie--f-e...!r5.cl.?.-\.. Sworn td and subscribed ore me Sworn to,and subscribe efore me this ? ` Day of .' , 20(4 rp this 3 Day of ,204- . �� `7`� 7 /liz _ Nofrr bike__ _ _ :, _ ? Pu 1c KYLE MURRAY KYLE MURRAY L �� ~ Nebry PubKc-8tat� f�i vised 012610 ...A.J.,-- • •• C01n[IIIti1011 I FF 9I1841 •4 ;., "P .Expirq Apr 2. � My Comm.Expires Apr 2,2020 61118919r m0 NOW Notary Lu DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA BUILDING CODE Review Result (circle onel: Approved Disapproved Approved w/ Conditions Review Initials/Date: Development Size Habitable Space // 7) S F, Non-Habitable Impervious area Miscellaneous Information Occupancy Group g2-3 Type of Construction V (-3 Number of Stories cg. Zoning District G - Max. Occupancy Load Fire Sprinklers Required Flood Zone / Conditions/Comments: ,wj-- � CITY OF ATLANTIC BEACH . ' ' PUBLICUTILITIESJ 1200SandpierLane� �131ATLANTIC BEACH,FL 32233 (904) 270-2535 or (904)247-5874 NEW WATER/SEWER TAP REQUEST Date: /0-ze?-/6 Project Address: /3O OeepLi 6697= Dr No. of Units: / Commercial Residential ✓ Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) 344 New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# go 5 — Z35-7 Water System Development Charge $ Sewer System Development Charge $ Water Meter Only $ /,95";DD Reclaim Meter Only $ Water Meter Tap $ (notes) Sewer Tap $ Cross Connection $ SO. OO Other $ TOTAL $ 23Sb APPROVED: Kayle Moore,PE (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED OFFICE COPY =Turner BRAIN OiiN:lC 480 EosEw000 AVENUE,Snurn,JACKSONVILLE,hauoA 32205 roc h1.;904-aB5330D•bo,999-353.1488•hist atule 533D5.1rw+v.nnoon n:s•,ca ControlS,.Man,GA.-912-576-1w CICALA,F .-852-351.838b What BuggingDAno a SEAM Fu.-386-7814309 You? M Fu.-321-951- POKY Si.l..lCK,-1 Fu.-7724524073 13 NOTICE OF INTENT FOR PREVENTATIVE TREATMENT AGAIINST1TERMITES as re.aired by Florida Building Codcs.FBC 104 2.6) Address: 0 �+C.r� ( tJ J L•O.A Lot: 1 b Block: 1:1" t{ --_Darer liUitA t Altl lnniticide(1XJisod Trcan�t�ytt) ALL STRUCTURAL CHANGES Product Used ARE TO BE REPORTED FOR RETREATMENT Dislulium Octaborate Tetral ydr4tt LIKAskyt an tenChemical used(active ingredient) Percent Concentration Annl t i_pli sg gpVt_lurWs unto utru{•rs n _ 41 r Stage of treatment(Horizontal,Vertical,Adjoining Slab,retreat of disturbed area)s01 BORA-CA RF•lennt_ticide anplicaticnshall be anolied accordingu►EPA rcgistratrd is rl Iircrliui»as stated iii the Florida Ruin-wg Lode Section 1816.1.S (INFORMATION TO BE PROVIDED TO LOCAL BUILDING CODE OFFICES PRIOR TO CONCRETE FOUNDATION INSTALLATION) FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-TRIPLEX-OUTSIDE-C-J-130 Builder Name: BEACHES HABITAT Street: 130 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville County:: DUVAL(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Frame Wood,Exterior R=19.0 1138.70 ft2 b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (572.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 572.00 ft2 6. Conditioned floor area above grade(ft2) 1172 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(130.0 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH: 1st Floor 6 165 a. U-Factor: Dbl,U=0.30 130.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 23.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (568.0 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 568.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.114 Total Proposed Modified Loads: 29.95 PASS Total Baseline Loads: 31.47 I hereby certify that the plans and specifications covered by Review of the plans and :•''�q1.E STq?;'•• this calculation are in compliance with the Florida Energy specifications covered by this � ' z cp ,:: Code. calculation indicates compliance :y ./, ,. .[+ with the Florida Energy Code. :n,,,'7K''.. ':€ ?,,,• 0 J PREPARED BY: FERNANDEZ(ESIGN) Before construction is completed ' 1, • ',''.--:.,:',**":.....:i 4 E 06/2016 ; c4; ; ` DATE: this building will be inspected for i,!', ;a compliance with Section 553.908 * -. i Florida Statutes. I hereby certify that this building,as designed, is in compliance C with the Florida Energy C . DD{yE 14: ......... .. OWNER/AGENT: BUILDING OFFICIAL: /Pk DATE: ( 0 '�t 7� DATE: I�'a 7'l - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: HABITAT-TRIPLEX-OUTSID Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1172 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 0 Street: 130 OCEAN GATE Permit Office: DUVAL COUNTY Cross Ventilation: No County: DRI DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 1172 9120 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 584 4544 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 588 4576 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 0 584 ft2 ____ 0.2 0 0.8 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 588 ft2 96 ft2 Medium 0.85 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 588 ft2 N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 Batt 588 ft2 0 Wood 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Clrnt Tn Wall Tyra S pace R-Values Ft In Ft In Aran R-VaI11P Frartinn Ahcnr r;raria% 1 SE Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 2 SW Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 3 NW Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 4 NE Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 5 SE Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 6 SW Exterior Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 7 NW Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 8 NE Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated 1st Floor Metal .46 3 6 8 20 ft2 2 S Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 SE 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 SE 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 3 SW 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 SW 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 SE 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 6 SE 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 7 SW 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 SW 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 NW 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 NW 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed CFM(50) .1 .00 .01 .0000 .0003 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 23.5 kBtu/hr 1 sys#1 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 24 kBtu/hr 720 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply--- —Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage 1st Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Venting tXi Jan ix c Feb X Mar X arr Apr r X May X Jun unn X Jul X Aug X Sel ikt.1 p X Oct X Nov v X Dec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index,the more efficient the home. 130 OCEAN GATE DRIVE, ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft2 b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 572.00 ft2 6. Conditioned floor area(ft2) 1172 b.N/A R= ft2 7. Windows** Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.30 130.00 ft2 11.Ducts R ft2 a.Sup: 1st Floor,Ret: 1st Floor,AH: 1st Floor 6 165 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 24.0 SEER:15.00 SHGC: d. U Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 23.5 HSPF:8.50 Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 568.00 ft2EF:0.92 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building •••""""""'' '41HEsto„•. Construction through the above energy saving features which will be installed (or exceeded) ��y' 0 `4. in this home before final inspection. Otherwise, a new EPL Display Card will be completed y ;;;�' ...z..s. -iP„,,`; based on installed Code compliant features. :l l( "".�0 Builder Signature: � ' Date: �y�� o Address of New Home: (30 d I C9- 0..vi V c_ City/FL Zip: c___D__g, .• 4 . Z3 °D 3 z_ . *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 130 OCEAN GATE DRIVE Permit Number: ATLANTIC BEACH ,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. ® 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces.New wood-buming fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. • R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. • R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ® R403.2.2 Sealing(Mandatory)111 ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ▪ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. • R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. • R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. • R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ® R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. 121 R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum • thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ▪ solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-TRIPLEX-OUTSIDE-C-J-130 Builder Name: BEACHES HABITAT Street: 130 OCEAN GATE DRIVE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/22/2016 3:35 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Job: HABIJAX-TRIPLEX-UNIT-... 4 wrightsoft Date: 06/2016 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE@ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT 130 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Notes: Desi• n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19249 Btuh Structure 14915 Btuh Ducts 2587 Btuh Ducts 3084 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21836 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17999 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1555 Btuh Ducts 828 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1172 1172 Equipment latent load 2383 Btuh Volume (ft3) 10260 10260 Air changes/hour 0.57 0.23 Equipment total load 20382 Btuh Equiv.AVF(cfm) 97 39 Req.total capacity at 0.78 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade 2.0 TON Trade 2.0 TON Model 25HBC524 Cond 25HBC524 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 0.8 HSPF Efficiency 15 SEER Heating input Sensible cooling 18720 Btuh Heating output 24000 Btu h @ 47°F Latent cooling 5280 Btuh Temperature rise 27 °F Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft 2016-Jun-22 15:22:17 Right-Suite®Universal 2013 13.0.09 RSU13554 Page 1 ...s\Wrightson HVAC\HABIJAX-TRIPLEX-UNIT-C-MJ.rup Calc=MJ8 Building Front faces: SE Duct System Summary Job: HABIJAX-TRIPLEX-UNIT-... 4 wrightsoft Date: 06/2016 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE@ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT 130 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 in/100ft 0.500 in/100ft Actual air flow 800 cfm 800 cfm Total effective length(TEL) 377 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk MECH h 541 28 10 0.500 4.0 Oxo VIFx 307.0 70.0 BATH2 h 813 41 29 0.500 4.0 Ox 0 VIFx 307.0 70.0 MBED h 3360 171 145 0.500 7.0 Ox 0 VIFx 307.0 70.0 BED3 h 2293 117 97 0.500 6.0 Ox 0 VIFx 307.0 70.0 KITCHEN h 2326 118 101 0.500 6.0 Ox 0 VIFx 307.0 70.0 BED2 h 2378 121 103 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT c 2152 85 149 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT-A c 2152 85 149 0.500 6.0 Ox 0 VIFx 307.0 70.0 BATH1 c 148 6 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 MWIc h 530 27 8 0.500 4.0 Ox 0 VIFx 307.0 70.0 C wrightsoft. Page 1 2016-Jun-2215:22:17 9 Right-Suite®Universal2013 13.0.09 RSU13554 ..s\Wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-c-MD.rup Calc=MJ8 Building Front faces:SE Manual S Compliance Report Job: QUADPLEX-OUTSIDE UNI... wrightsoft Date: 06/2016 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE@ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT 130 OCEAN GATE DR,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.0°F Sensible gain: 17931 Btuh Entering coil DB: 76.2°F Outdoor design WB: 78.0°F Latent gain: 2425 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 20356 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A**30+FX4DNF025 Actual airflow: 800 cfm Sensible capacity: 21971 Btuh 123%of load Latent capacity: 744 Btuh 31%of load Total capacity: 22715 Btuh 112%of load SHR: 97% Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21480 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A**30+FX4DNF025 Actual airflow: 800 cfm Output capacity: 23554 Btuh 110%of load Capacity balance: 36 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 5.2 kW 83%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Jun-22 15:22:17 wrightsoft Right-Suite®Universal 2015 15.0.17 RSU13554 Page 1 A ...htsoft HVAC\HABIJAX-QUAD-OUTSIDE UNIT-C-MJ2.rup Calc=MJ8 Building Front faces: SE Ali `_w - fol 11 m BATHROOM 8'CLG. (UTILITY MASH & 10x6x6 1 R•CLG. TRASH & PATIO (AI� 1 j j y ' PATIO -- Il l►•a J !�41 r U UJ '� — 4 — a (I >— . 1 UTILITY ,j.j UTILITY — CLOSET 8'ac. KITCHEN 8'CLG. - T 8'CLG. . CC Z I- Q Z KITCHEN / 10" a 8x4x4 10X6X6 8'CLG. \ Kil, if..N 8x4x4 [ 1 © . .AHU • BATHR00 BATHROOM 10X6X6 / 4 8'CLG. ■ • 8'CLG. = \ \\\ —J 12" ,_i © ■ OUVERED 0 12" I DOOR AHU 16G TG 0 O IAHU O16X20I MECH A7 7'-8'CLG _ 10X6X6 ■ �� 10X6X6 �'-e'ac. -12 12"- STORAGE, STORAGE VARIES III 10X6X6 VARIES GREAT ROOM GREAT ROOM \ 8'CLG. 8'CLG. GREAT ROOM 8'CLG. 10X6X6 ■ ■ 10X6X6 ■ 10X6X6 ht I. h h__d .^. d .—,lh 1� FRONT PORCH n 0 i°' i0 r4; ini FRONT PORCH DI `O] UNIT 'A' UNIT 'B' UNIT 'C' BEACHES _ A3 TAT 138-134-130 OCEAN GATE DRIVE ATLANTIC BEACH, FL 32233 TRIPLEX MECHANICAL PLAN - M1 u BEDROOM BEDROOM BEDROOM k2 BEDROOMBEDROOM 1 a is 8'CLG. / 3 8'CLC. 8'CLG. \ 8'CL. 10X6X6 10X6X6 10X6X6 8'ac. //� 10X6X6 /\ 10X6X6 • ii'� �10 ", ■ 1 TG I 10" Y TG06 �D�10 12x1 a V 12�� 8x4x4 8x4x4 L1 i BATHROOM / FATHR00M q //\Jj 8 CLG. ' 8'CLG. 1 // lj 12" ! 12" o J _ , - L \ a 8x4x4 . TG / / 12x10 \ ' a e - BATHROOM 12x10 \ _ 14 ' \ TG .- 8'CLG j / 12x10 a 12x6x7 12x6x7 ■ \1 8x4x44 MASTER 10X6X6 MASTER Q8x4x4 BEDROOM MASTER BEDROOM 1+ CLOSET - e CLG. BEDROOM 8'CLC. 8'CLG. CLOSET 8'CLG. 8'CLG. tl h A ) 11- 1 -- h tl LI--fl UNIT 'A' UNIT 'B' UNIT 'C' BEAC - - S _ AB TAT 138-134-130 OCEAN GATE DRIVE ATLANTIC BEACH, FL 32233 TRIPLEX MECHANICAL PLAN - M2 City of Atlantic Beach APPLICATION NUMBER it . Building Department (To be assigned by the Building Department.) 1. - 800-Seminole Road Q� ) Atlantic Beach, Florida 32233-5445 '�( �FPCT o� Phone (904)247-5826 • Fax(904)247-5845 I E-mail: building-dept@coab.us Date routed: it t Let No City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 13o oc n elm)2_ of. De artment review required Yes No A, Buildin o. Applicant: O1 J'Ut ham'f c 'tons tic.-{zn Plannin &Zonin Tree Administrator Project: rLLOo1+SAD(9 stnGtkt- fin Ill ublic Works 3 V 1 Public Utilities ��is U � �OOVZ Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: )pproved. ['Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING iy Reviewed by: _/ �� (��� Date: /b/ TREE ADMIN. Second Review: 'Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 olAnf,,, City of Atlantic Beach APPLICATION NUMBER �s \ Building Department J s) 800 Seminole Road _ (To be assigned by the Building Department.) <` „r Atlantic Beach, Florida 32233-5445 I• n I h—S FMS ` o� �- lir) Phone(904)247-5826 • Fax(904)247-5 OCT 2 O 2016 AZo t EE-mail: building-dept@coab.us : ` Date routed: ItIlei No City web-site: http://www.coab.us LM APPLICATION REVIEW AND TRACKING FORM Property Address: 130 C(,Q-an 2 -},- 3(, Dekartment review required Yes No A' /� ,, Buildin Applicant: o�UL 1M�� pof# Ofl 1U(iion Plannin &Zonin Tree Administrator Project: if\t.,{,,0p�'S\Q19 SI(1GV- -affl i (y ublic Works (ti hOotvz V Public Utilities Public Safety Fire Services Review fee $ 50 Dept Signature `,Xe Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APP�TION STATUS Reviewing Department First Review: ApAproved. I 'Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING 14-1/....- V Y2/ /Reviewed by: , 1 Date: /o(2f1(6 TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. IAII •WORKComments: 'UBLIC UTILITIES /0 —Zo—/L PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. ['Denied. Comments: Reviewed by: Date: Revised 05/14/09 ol..m;.i, City of Atlantic Beach APPLICATION NUMBER s � Building Department °Ert- +- (To be assigned by the Building Department.) t I� �� 800 Seminole Road � � I �' o�359- - ' r) Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 Fax(904) 247-5845 T 2 2016 • Date routed: ��t�"L b i J,tiO. , E-mail: building-dept@coab.us City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 13o E)LC.n C-►� t L Oi. De artment review required Yes No 1 /^� ,^, Buildin o. Applicant: O1 JAA,,v`�� pof� wfS uc On Planning &Zonin Tree Administrator Project: \L,,1^) st( 8`t— --amt lyublic Works cti\-ctOmati IfkOAQ. Public Utilities Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Date Other Agency Review or Permit Required of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. Denied. (Circle one.) Comments: —1# 441/14 4111/44* BUILDING PLANNING &ZONINGReviewed by: % Date: / �(o TREE ADMIN. Second Review: Approved as revised. ❑ ,. . PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 v--17-0../ (1-.- J1../ ;,- 2 -:, o,pf;-, on(,a/ hicYonfq / 1/:11 31 --t/X44/ 1 - i 1/ rityrtv� 0?-/ ' 17 or 'y v ry _-+ G'/ter" . ,_.1-- -• ./ x_rios ^ "'' 4c. ! u, ll = Y:`8ff; arks I! ‘'.100AVvQ T(rE f?' A A .x hi-oircli till IV ° i x ."1,/ YAW -re? ✓. . x^1' l YIN i7.10 1 ? '7/ ..xyziy p x ,t4i . .- 2--:-ovs-, .. y71.f,r-u hpv-i.95/ty 01 ^ x i id!31911' 1 A 'i/ .k. 4 b x // 11'✓m/ reV ori Ai 1 .n lr rii 71 s ,-1`h, js / x..i 'Q4- . / 49,1`2"/, 5.- of9 % n -07 A:i ~,v 40(71441-g20 g2Q oi/ Permit Attachment of__ __ for Permit# issued 20 Atlantic Beach,FL 32233 Owner's Name: g-eik c S [ i ._. Property Address: r 3 0 R.E. #: (�4 i3 8 �('e , ` 4vim_ Subdivision: e (, _ Lot#/Block#: L 1.--•6 C`g, 9 to REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this day of by Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State Florida, hereinafter referred to as "CITY" and L3G,a t of hereinafter referred to as "USER". -- (- � E of Atlantic Beach, Florida, WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the rih enter upon the property of the City of Atlantic Beach for the g t to Beach Right-of-Way/Easement permit numbers noted above(copies purpose bed in the City of Atlantic This work is generally described as: [t . v-e.Ars •, dv-CucUAL. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty given b ( 0)days notice by CITY to the USER, said notice to USER shall be l y certified ,mail, return receipt requested, to the following address: OA& . ...l- ! . 4 • The depositing of said notice of cancellation in the United States mail shall constitute the noti cancellation and the burden is upon USER to keep the CITY informed of USER'S proper address. ce of The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility enter upon the above-described property of the CITY, the USER shall replace at the USER'S sole expense any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing, or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code, and all other land use and code requirements of the CITY, including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 The USER, prior to making any changes from the approved approval from the City of Atlantic Beach, Public Worms Department,plans and/or method, must obtain written discretion of the CITY, be requested to submit as-built drawings showing ngs for said change. wit USER shall,at the after the day of completion. the change within thirty (30) days This permit shall insure to the benefit of, and be binding upon, the USER assigns, and their respective successors and • USER shall meet the terms and conditions of this permit and to all of and/or specifications, to include utilities locate requirements the applicable State and CITY laws rights-of-way d/orsand other public land. USER fia q and use limitations/requirements saved harmless by the USER fromrther agrees that the CITY and iofficrand employees • bliabilities are hereby assumed b any of the work herein under the terms of this permit and that all of said 13,L)he USER. DAT, • and SIGNED this. '�'/ day of 204.. 10 - . By: ,,, Property Owner . (to be signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DIIVAL On this day of me, and for said County and 20_, personally appeared before a Notary ry Public in and who executed the fore going 'Atlantic Beach, Florida lmown the property owner of to me to be the person(s)described in and voluntarily g g m purpos ; who acknowledged to me that he or she executed the same freely Y and for the uses and purposes therein mentioned. Notary Public in for said County and State CITY OF ATLANTIC BEACH, FLORIDA a municipal corporation: ' Approved: -moi Nettg-L-rrytem, w Pu• i Q ks Arrector Det„,,a v. u. -,LZ, R C� For Permits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2