81 5TH ST - HVAC -S r��`J\_ �" i* � , CITY OF ATLANTIC BEACH ;--, . .,.. -. ,_ . ;) 800 SEMINOLE ROAD jtl ;r ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 J.21>r MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 17-MECH-2962 Job Type: MECHANICAL HVAC ONLY Description: install one (1) 3.0-ton 36K-BTU & one (1) 1.5-ton 18K-BTU AHU Estimated Value: $12,000.00 Issue Date: 1/10/2017 Expiration Date: 7/9/2017 PROPERTY ADDRESS: Address: 81 5TH ST RE Number: 170151-0000 PROPERTY OWNER: Name: Sabatier, Nadine Address: 81 5Th ST GENERAL CONTRACTOR INFORMATION: Name: B & G PLUMBING, HEATING &AIR CONDITIONING LLC Scott. E. Martin, CAC1814123 Address: 2232 CORPORATE SQUARE BLVD Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Work W/O Permit Mechanical $110.00 AC and Refrigeration $36.00 Air Duct System $20.00 Furnaces and Heating $20.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $110.00 Total Payments: $300.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA 1 BUILDING CODES. 1-u;yf, City of Atlantic Beach APPLICATION NUMBER mss • Building Department (To be assigned by the Building Department.) A ! -� J 800 Seminole Road _ Jv h �-t�:�� 'i ( �T 9 ri e Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 I ,^1 0.219r E-mail: building-dept@coab.us Date routed: Ci ` V CI 111- City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: De_padment review required Yes o uilding—� Applicant: 1`31)i j h _tti �(� '� G.t Planning &Zoning �J , ,1 Tree Administrator Project: \t ;\�1 a k tS - ,S��L t �C �u� / Public Works PiY� 6 co LiA` i,J11J Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Rpproved. ['Denied. (Circle one.) Comments: BUILDIN p PLAN G &ZONING Reviewed by: !'�// Date: /— ! -t'7 TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. Comments: Reviewed by: Date: Revised 05/14/09 MECHANICAL PERMIT APPLICATION , JLor A�� �i CITY OF ATLANTIC BEACH 70 v 19 7 OFFICE COPY 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax (904)247-5845 11-- b1(--- C V4— d`I to 7 JOB ADDRESS: R I S } •gA- • PERMIT# " S az 5317 PROJECT VALUE $ ‘ Z , o U ARI# I li H in o et o REQUIRED Air Handling Equipment Only /Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Z Tons Per Unit 3 / I . Heat: Unit Quantity 2. BTU's Per Unit 3 to,o 0 oSeer Rating t H Duct Systems: Total CFM i goo t 8, o oa REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty ----�`,-�-�-- Automobile Lifts Gas Piping Outlets r I �E Q V E Boilers BTU's Elevators/Escalators ALL OTHER GAS PI I eat Exchanger Quantity of Outlets 1 AN - q 2017 I'umps #Vented Wall Furnace t # Water Heaters ;` .olar Collection Systems 4I anks(gallons) __...--- ells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name NiA t,;4 E Ag Al'+E 4 Phone Number 5 H O N ck t Mechanical Company Q, k ( .(A Q ;IN 3 .v) t kA 1:54 A\0. Office Phone 213-3 SSC Fax `I`t 4-Z no to Co. Address: a a 2- G r;,; (\c R ATE, , c .;A 0.£ i.k.i. City '3"-A'#- State F\ Zip 3 z z\ b License Holder(Print): 5 ct-r.c � . c' State Certification/Registration# G At.+ai 1-.\)2-3 No , 11-7.;--- :---.. ....-- — ----' • _ er _ %'d-- I,✓� o;;�.., •' JENNIFER JOHNSTON 1 �� ••• fit: . MY COMMISSION N GG 042984 I.efore me this day of u n actit{ 20 . i -•., :: EXPIRES:October 27,2020I t ; ••�^' Bonded Ttw Notary Punic Underwritersignature of Notary Public \. ,,,4, A FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page) and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level (EPL) Display Card (one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) REVIEWED FOR CODE COMPLIANCE OFFICE COPY CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS REVIEWED BY; 771 p,DATE: / ! / 7 EnergyGaug + -USRCSB v5.1 Page 1 of 1 1/9/2017 10:22:17 AM 411 M\ . FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Sabatier Residence Builder Name: Street: 81 Fifth St Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3153.2 sqft.) Insulation Area a.Frame-Wood,Exterior R=13.0 2900.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 252.90 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types , s t.) Insulation Area 5. Is this a worst case? No a.Roof D (Unvente ) R=21.0 1624.00 ft2 R= ft2 6. Conditioned floor area above grade(ft2) 2607 b.N/A R= ft' c.N/A Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 278.33 7. a.WU-Factor: sqft.) Dbl,Description= .4Area ft2 b.Sup: Attic,Ret:Attic,AH:1st Floor Bedroom Suite 6 60.58 a. U-Factor: U=0.40 539.53 SHGC: SHGC=0.25 ft' 12.Cooling systems kBtu/hr Efficiency SHGC: b. N/A a.Central Unit 33.0 SEER:14.00 SHGC: b.Central Unit 17.8 SEER:14.00 c. U-Factor: N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a.Electric Heat Pump 33.8 HSPF:8.20 SHGC: b.Electric Heat Pump 17.6 HSPF:8.20 Area Weighted Average Overhang Depth: 3.478 ft. 14.Hot water systems Area Weighted Average SHGC: 0.250 a.Electric Cap:55 gallons 8. Floor Types (2607.0 sqft.) Insulation Area EF:0.920 a.Crawlspace R=13.0 1136.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1108.00 ft' None c.other(see details) R= 363.00 ft' 15.Credits None Total Proposed Modified Loads: 77.21 PASS Glass/Floor Area: 0.207 Total Baseline Loads: 79.53 I hereby certify that the plans and specifications covered byReview of the plans and :••''�• IM ST,gT•••.• this calculation are in compliance with the Florida Energy specifications covered by this ,, ;',;'_ .`0,�; t , . .[. Code. v calculation indicates compliance : ry,���,.. ��;..4% -, V Ryan B.Ellis with the Florida Energy Code. ? :;rrr��: ..... :.*A Before construction is completed f 1 i ".,t PREPARED BY: : a 0 DATE: 119/17 _ this building will be inspected for 1 c.,) a : compliance with Section 553.908 *`., ,' I lorida Statutes. � ��� . hereby c:.•• . at this building,as designed, is in comp i• •' O�� wi • e Florida Energy�Qde.�y �� ,/ OWNER/AGENT ✓1�1�, �1lYnl ��'`-vn,'nv UILDING OFFICIAL: DATE: 19 9 J.- DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as c- ied factory-sealed in accordant• ith R403.2.2.1. -Complian - • -- • =• ter and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 1/9/2017 10:22 AM EnergyGauge®au e®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Bedrooms: 3 Address Type: Street Address Title: Sabatier Residence Lot# Building Type: User Conditioned Area: 2607 Total Stories: 2 Block/SubDivision: Owner: #of Units: 1 Worst Case: No PlatBook: Rotate Angle: 0 Street: 81 Fifth St Builder Name: County; Duval Permit Office: Atlantic Beach Cross Ventilation: Whole House Fan: City,State,Zip: Atlantic Beach, Jurisdiction: 261100 FL, Family Type: Single-family New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT_NS FL_MAYPORT_NS 2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume 1 Block/ 2141 20445.8 2 Block2 466 4194 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor Main Living 670 6030 Yes 1 1 Yes Yes Yes 2 1st Floor Bedroom S 466 4194 Yes 1 1 1 Yes Yes Yes 3 2nd Floor 1471 14415.8 Yes 3 2 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Crawlspace 1st Floor Main Livi 83.6 ft 0 670 ft2 13 0 0 1 2 Crawlspace 1st Floor Bedroom 88.4 ft 0 466 ft2 13 0 0 1 -- 3 Floor over Garage -- 2nd Floor ___ 363 ft2 0 0 0 1 4 Floor Over Other Space 2nd Floor ____ ___ 642 ft2 0 0 0 1 5 Floor Over Other Space 2nd Floor _-_ ___ 466 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch J # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1624 ft2 0 ft2 Medium 0.96 No 0.9 No 21 22.6 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1499 ft2 N N 1/9/2017 10:22 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING J Space R-Value Ins Type- Area Framing Frac Truss Type - _ V _ # Ceiling Type 1 Under Attic(Unvented) 1st Floor Main Livi 0 Blown 30 ft' 0.11 Wood 2 Under Attic(Unvented) 2nd Floor o Blown 1594 ft' 0.11 Wood WALLS Cavity Width Height Sheathing Framing Solar Below V#_ Ornt - Tm Adjacent Space R_V u FtJn- --Ft __In Area- _R-Value Fraction Absorr_Grade%- - �JVaU-Type- __ 109.8 ft' 0.05 0.170000 0 1 W Exterior Frame-Wood 1st Floor Main 13 12.2 9 9 ft' 0.05 0.170000 0 _ 2 S Exterior Frame-Wood 1st Floor Main 13 27.1 9 243. 0.05 0.170000 0 3 E Exterior Frame-Wood 2nd Floor 13 14.5 9 130.5 ft' 4 E Exterior Frame-Wood 2nd Floor 13 11.7 9 105.3 ft' 0.05 0.170000 0 5 E Exterior Frame-Wood 1st Floor Bedr 13 7.8 9 70.2 ft' 0.05 0.170000 0 _ 6 E Exterior Frame-Wood 1st Floor Bedr 13 6 9 54.0 ft' 0.05 0.170000 0 7 N Exterior Frame-Wood 1st Floor Bedr 13 41.8 9 376.2 ft' 0.05 0.170000 0 8 W Exterior Frame-Wood 1st Floor Bedr 13 9 9 81.0 ft' 0.05 0.170000 0 9 S Garage Frame-Wood 1st Floor Bedr 13 19.1 9 171.9 ft2 0.05 0.170000 0 _10 W Garage Frame-Wood 1st Floor Bedr 13 4.7 9 42.3 ft' 0.05 0.170000 0 11 N Garage Frame-Wood 1st Floor Main 13 4.3 9 38.7 ft' 0.05 0.170000 0 12 W Exterior Frame-Wood 2nd Floor 13 40.3 9.8 394.9 ft' 0.05 0.170000 0 13 S Exterior Frame-Wood 2nd Floor 13 41.6 9.8 407.7 ft' 0.05 0.170000 0 14 E Exterior Frame-Wood 2nd Floor 13 40.3 0 9.8 394.9 ft' 0.05 0.170000 0 15 N Exterior Frame-Wood 2nd Floor 13 41.6 9.8 407.7 ft' 0.05 0.170000 0 16 W Exterior Frame-Wood 1st Floor Main 13 13.8 9 124.2 ft' 0.05 0.170000 0 DOORS / Space Storms U-Value Width Height Area- V # Ornt Door Type Ft In Ft In -- - - - 16.8 ft' 1 W Wood 1st Floor Main None .46 2.5 6.7 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.4 0.25 24.0 ft2 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 2 W 1 Vinyl Law-E Double Yes 0.4 0.25 9.4 ft' 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 3 S 2 Vinyl Low-E Double Yes 0.4 0.25 42.1 ft' 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 4 E 3 Vinyl Low-E Double Yes 0.4 0.25 40.2 ft' 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 5 E 4 Vinyl Law-E Double Yes 0.4 0.25 3.5 ft' 14 ft 0 in 1 ft 0 in Drapes/blinds None 6 E 4 Vinyl Low-E Double Yes 0.4 0.25 18.1 ft' 14 ft 0 in 1 ft 0 in Drapes/blinds None 7 E 5 Vinyl Low-E Double Yes 0.4 0.25 24.3 ft' 14 ft 0 in 1 ft 0 in Drapes/blinds None 8 E 6 Vinyl Law-E Double Yes 0.4 0.25 12.2 ft' 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 9 N 7 Vinyl Low-E Double Yes 0.4 0.25 16.8 ft' 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 10 N 7 Vinyl Low-E Double Yes 0.4 0.25 4.0 ft' 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 11 N 7 Vinyl Low-E Double Yes 0.4 0.25 16.2 ft' 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 12 W 12 Vinyl Low-E Double Yes 0.4 0.25 21.6 ft2 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 13 W 12 Vinyl Low-E Double Yes 0.4 0.25 28.1 ft' 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 1/9/2017 10:22 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered,Proposed orientation Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 14 S 13 Vinyl Low-E Double Yes 0.4 0.25 28.1 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 15 W 12 Vinyl Low-E Double Yes 0.4 0.25 42.1 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 16 S 13 Vinyl Low-E Double Yes 0.4 0.25 84.2 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 17 E 14 Vinyl Low-E Double Yes 0.4 0.25 41.6 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 18 E 14 Vinyl Low-E Double Yes 0.4 0.25 26.8 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 19 E 14 Vinyl Low-E Double Yes 0.4 0.25 28.1 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 20 E 14 Vinyl Low-E Double Yes 0.4 0.25 18.1 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None 21 N 15 Vinyl Low-E Double Yes 0.4 0.25 5.1 ft2 2.5 ft 0 in 12 ft 0 in Drapes/blinds None 22 N 15 Vinyl Low-E Double Yes 0.4 0.25 5.0 ft2 2.5 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 402 ft2 402 ft2 37.2 ft 10.2 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Whdehouse Proposed ACH(50) .0003 2053.3 112.72 211.99 .2847 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 33.8 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8.2 17.6 kBtu/hr 2 sys#2 COOLING SYSTEM __ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 33 kBtu/hr 990 cfm 0.75 1 sys#1 2 Central Unit None SEER:14 17.8 kBtu/hr 534 cfm 0.75 2 sys#2 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor Main LG 9lti 55 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF ft` None None 1/9/2017 10:22 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 DUCTS / ----Supply---- ---Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 278.33 f Attic 107.05 f Default Leakage Attic (Default)c(Default)c 1 1 2 Attic 6 60.58 ft' Attic 23.3 ft' Default Leakage 1st Floor Be (Default)c(Default)c 2 2 TEMPERATURES Programable Thermostat: None Ceiling Fans: Cooling Jan Feb ]Mar Apr May (X Jun X Jul X Aug Dec NNonvv ,x)Dec Heating X Jan X Feb 1 Mar Apr l May l Jun Jul Aug Sep XJ Oct X Nov Dec Venting Jan Feb X]Mar X Apr [ May l 1 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(W EH) A8 78 78 8 78 78 PM 78 78 78 78 78 78 8 78 78 78 78 78 8 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(W EH) AM 68 68 68 68 68 68 68 68 68 6 68 68 68 8 68 68 68 68 68 68 68 68 68 1/9/2017 10:22 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 81 Fifth St, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=13.0 2900.30 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 252.90 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 2 d.N/A R= f1 4. Number of Bedrooms 3 Insulation Area l 10.Ceiling Types 5. Is this a worst case? No a.Roof Deck(Unvented) R=21.0 1624.00 ft2 6. Conditioned floor area(ft2) 2607 b.N/A R= ft2 c.N/A R= ft2 7. Windows" Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.40 539.53 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 278.33 SHGC: SHGC=0.25 b.Sup: Attic,Ret:Attic,AH:1st Floor Bedroom Suite 6 60.58 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 33.0 SEER:14.00 b.Central Unit 17.8 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 33.8 HSPF:8.20 Area Weighted Average Overhang Depth: 3.478 ft. b.Electric Heat Pump 17.6 HSPF:8.20 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14.Hot water systems Cap:55 gallons a.Crawlspace R=13.0 1136.00 ft2 a.Electric EF:0.92 b.Floor Over Other Space R=0.0 1108.00 ft2 b. Conservation features c.other(see details) R= 363.00 ft2 None 15.Credits None I certify that t ' me has complied with the Florida Energy Efficiency ::- •r Buildin• •••.... ..srgj;• Constr . 'on through the above energy saving features which will be installed(or ex - :-• ` 04: .:.........." F in th'- home before final inspection. Otherwise, a new EPL Display Card will be completed ; co :. ,.f.3' ;,,, ,,. ba--d on installed Code compliant features. 1.,""„ _ '•'„•3„ o t. B ilder Signature: �,tQ,n, Date: 1 �� �Q '� a • As•ress of New Home: g t 5 Wt vie 1 _ City/FL Zip: . �' Y. v9� • cOh w ..••'' *N• e: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mort•-•e(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-149 •r see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information abouthe Florida Building Code, Energy Conservation ntact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/9/2017 10:22 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 81 Fifth St Permit Number: Atlantic Beach.FL. MANDATORY REQUIREMENTS See individual code sections for full details. X 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law(Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. X R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. X R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1.as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors.fireplace and stove doors shall be closed,but not sealed.beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test.shall be open: 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed: 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. X R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. X R402.4.3 Fenestration air IeakagelNindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/W DMA/CSA 101/l.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. X R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. X R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. X R403.1.3 Heat pump supplementary heat(Mandatory)Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. X R403.2.2 Sealing(Mandatory,All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99.Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm(85 L/min)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 1/9/2017 10:22 AM EnergyGaug + USA-FlaRes2014 -Section R405.4.1 Compli Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. X R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. 0 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. X R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'A inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. X R403.4.4 Water heater efficiencies(Mandatory). X R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100"F to 140 F(38 C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water heating systems to be turned off. X R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. 0 R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. X R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for coding and heating equipment. X R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 1/9/2017 10:22 AM EnergyGaug + USA-FlaRes2014 -Section R405.4.1 Compli Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) X R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. X R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. X R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events.shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. O R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and 0404 of the Commercial Provisions in lieu of Section R403. O R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55-F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal ▪ efficiency of 82 percent for heaters manufactured on or after April 16.2013 when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with • AHRI 1160.Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar ▪ energy source computed over an operating season. X RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights X R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. X R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 1/9/2017 10:22 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compli Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Sabatier Residence Builder Name: Street: 81 Fifth St Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. X Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. X Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. X Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and X Rim joists Rim joists are insulated and include an air barrier. X Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. X The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. X Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or X unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled X by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. X Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be X air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to X available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air X barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or X air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be X sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have X gasketed doors 1/9/2017 10:22 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Date: 117117 4 wrightsoft° 1st& 2nd Firs By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville,FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.jax@ arnail.com Project Information For. Sabatier Residence 81 Fifth St,Atlantic Beach Notes: Desi• n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 Moisture difference 50 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19520 Btuh Structure 28233 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19520 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load B 7Stuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2880 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heati ng Cooling (none) Area(ft2) 2141 2141 Equipment latent to tuh Volume(ft3) 20446 20446 Air changes/hour 0.33 0.14 Equipmen ' Btuh . Equiv.AVF(cfm) 113 49 o a capacity at 0.78 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade BRYANT HEATING AND COOLING SYS... Trade BRYANT HEATING AND COOLING SYS... Model 214DNA0360000B0 Cond 214DNA0360000B0 AHRI ref Coil FB4CNP036L AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 23100 Btuh Heating output 33800 Btuh @ 47°F Latent cooling 9900 Btuh Temperature rise 28 °F Total cooling 33000 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Capacity balance point = 24 °F Backup: Input = 6 kW, Output= 19520 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft. eon-Jan-os 10:22:08 9 Right-Suite®Universal 2017 17.0.17 RSU17457 Page 1 ACCK ...J\Sabatier Residence,81 Fifth St.All Bch.nip Calc=MJ8 Front Door faces: W -PkProject Summary Date: 1/7/17 wrightsoft 1st Fl Bdrm Ste By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd.Jacksonville. FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.ji3xCgrnail.com Pro'ect Information For: Sabatier Residence 81 Fifth St,Atlantic Beach Notes: Desi s n Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F Outside db 94 °F Inside db 68 °F Inside db 75 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 5619 Btuh Structure 12970 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 5619 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sen_sibleloa 1'19Ttuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2966 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 466 466 Equipment latent Iced V• P Btuh Volume(ft3) 4194 4194 Air changes/hour 0.55 0.24 Equipment total load r1' Btuh Equiv.AVE(cfm) 38 17 Req. total capacity at 0.70 SHR f.5 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade BRYANT HEATING AND COOLING SYS... Trade BRYANT HEATING AND COOLING SYS... Model 214DNA0180000A0 Cond 214DNA0180000A0 AHRI ref Coil FB4CNP018L AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17600 Btuh @ 47°F Latent cooling 5340 Btuh Temperature rise 27 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.106 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Capacity balance point = 10 °F Backup: Input = 1 kW, Output= 4908 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Jan-09 10:22:08 Wrightsoft" Right-Suite®Universal 2017 17.0.17 RSU17457 Page 2 AC. K ...J\Sabatier Residence.81 Fifth St.Atl Bch.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: -�- wrightsoft' p Date: 1!1117 1st & 2nd Firs By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville,FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:8ds.laxgarail.com Project Information For: Sabatier Residence 81 Fifth St,Atlantic Beach Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 28233 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latent gain: 2880 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 31112 Btuh Indoor RH: 50% Estimated airflow: 1100 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer. Bryant Model: 214DNA0360000B0+FB4CNP036L Actual airflow: 1100 cfm Sensible capacity: 24420 Btuh 86% of load Latent capacity: 8580 Btuh 298% of load Total capacity: 33000 Btuh 106% of load SHR: 74% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 19520 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer. Bryant Model: 214DNA0360000B0+FB4CNP036L Actual airflow: 1100 cfm Output capacity: 33800 Btuh 173% of load Capacity balance: 24 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1100 cfm Output capacity: 5.7 kW 100% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2017-Jan-09 10:33:01 �`. wrightsoft Right-Suite®Universal 2017 17.0.17 RSU17457 Page 1 ACC ...ISabatier Residence,81 Fifth St.Ati Bch.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: wrightsoft' P p Date: 1nn7 1st Fl Bdrm Ste By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville,FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.iaxgama l comp Project Information For: Sabatier Residence 81 Fifth St,Atlantic Beach Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 12970 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latent gain: 2966 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 15936 Btuh Indoor RH: 50% Estimated airflow: 593 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 214DNA0180000A0+FB4CNP018L Actual airflow: 593 cfm Sensible capacity: 13172 Btuh 102% of load Latent capacity: 4628 Btuh 156% of load Total capacity: 17800 Btuh 112% of load SHR: 74% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 5619 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Bryant Model: 214DNA0180000A0+FB4CNP018L Actual airflow: 593 cfm Output capacity: 17600 Btuh 313% of load Capacity balance: 10 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer Model: Actual airflow: 593 cfm Output capacity: 1.4 kW 87% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2017-Jan-09 10:33:01 -1* wrightsoft Right-Suite®Universal 2017 17.0.17 RSU17457 Page 2 JtSabatier Residence,81 Fifth St,All Bch.rup Calc=MJ8 Front Door faces: W N-.11111,\*1 1st Floor 8.41 cfm Bed 3 Wet Bar �� 266 cfm L.. ndry 6 " Foyer/Game 10 " 41 cfm Powder •14 " 600 cfm 4 Hall •257 cfm up Riser 8 " 8 „ Breakfast , 170 cfm 4 " 166 cfm Bath 3 Job#: Scale: 1 : 70 Exclusively for the use of: Performed for: Page 1 Sabatier Residence B&G Plumbing,Heating and Air Ccnditiori rg Right-Suite®Universal 2017 17.0.17 RSU17457 81 Fifth St 2017-Jan-09 10:31:30 Atlantic Beach ...idence.81 Fifth St.N Bch.rup Afc 2nd Floor Master Bed Living Kitchen 7 „ 7 7" 3.107 cfa 71 cfm 3 71 cfm •89 cf _ • cfm ;• cfm 6 " 10 " 14 " 4 " 76 cfm 111 ser j 358 cfm WIC 1 4 10 " Stairs 10 . 2, cfm rail 531 cf • 133 cfm 75 cfm at 212 4 " 7 „ Bed 2 119 cfm Master Bath Job#: Scale: 1 : 70 Exclusively for the use of: Performed for: Page 2 Sabatier Residence B&G Plumbing,Heating andAirConditiori rg Right-Suite®Universal 2017 81 Fifth St17.0.17 RSU17457 2017-Jan-09 10:31:30 Atlantic Beach ...idence.81 Fifth St.Al Bch.rup eld_ wrightsoft' Duct System Summary Date: 1st & 2nd Firs By: Exclusively for the use of: B&G Plumbing,Heating and Air Conditioning Project Information For: Sabatier Residence 81 Fifth St,Atlantic Beach Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/ return available pressure 0.065/0.035 in H2O 0.065/0.035 in H2O Lowest friction rate 0.046 in/100ft 0.046 in/100ft Actual air flow 1200 cfm 1200 cfm Total effective length(TEL) 217 ft Supply Branch Detail Table I Design I Htg I Clg I Design I Diam I H x W I Duct I Actual I Ftg.Eqv 1 Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath2 c 805 24 24 0.057 4.0 Ox 0 VIFx 15.3 100.0 st2 Bed 2-A c 4422 132 133 0.055 8.0 Ox 0 VIFx 19.8 100.0 st2 Foyer/Game h 8031 257 236 0.065 8.0 Ox 0 VIFx 20.1 80.0 Kitchen c 3558 97 107 0.051 7.0 Ox 0 VIFx 29.4 100.0 st1 Laundry h 1279 41 37 0.065 6.0 Ox 0 VIFx 20.4 80.0 Laundry-A h 1279 41 37 0.074 4.0 Ox 0 VIFx 8.9 80.0 Living c 2366 68 71 0.049 7.0 Ox 0 VIFx 33.4 100.0 st1 Living-A c 2366 68 71 0.046 7.0 Ox 0 VIFx 42.3 100.0 st1 Master Bath c 3958 117 119 0.056 7.0 Ox 0 VIFx 17.5 100.0 st2 Master Bed c 2954 86 89 0.049 7.0 Ox 0 VIFx 32.6 100.0 st1 Master Bed-A c 2954 86 89 0.053 7.0 Ox 0 VIFx 23.8 100.0 st1 Stairs c 25101 74 75 0.047 4.0 Ox 0 VIFx 38.6 100.0 st1 WIC 1 c 2541 75 76 0.048 6.0 Ox 0 VIFx 37.2 100.0 st1 WIC 2 c 11781 341 35 I 0.0481 4.01 Ox 0 1 VIFx 1 36.0 100.0 st1 Supply Trunk Detail Table Trunk I Htg I Clg I Design I Veloc I Diam I H x W I Duct I I Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 589 614 0.046 574 14.0 0 x 0 VinIFIx I st2 Peak AVF 272 276 0.055 351 12.0 I 0 x 0 VinIFIx I Bold/italic values have been manually overridden 2017-Jan-09 10:31:15 .L -11F wrightsoft RightSuites Universal 2017 17.0.17 RSU17457 Page 1 /,glrTil6t .. D\Sabatier Residence,81 Fifth St,Atl Bch.rup Calc=MJ8 Front Door faces: W Return Branch Detail Table Grille I Htg I Clg TEL 'Design Veloc IDiam I H x W I Stud/Joist I Duct I Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb6 Ox 0 322 326 47.3 0.073 598 10.0 Ox 0 VIFx rt1 rb5 I Ox 0 I 5311 5151 38.1 1 0.091 9741 10.01 Ox 0 I 1 VIFx 1 rt1 rb4 Ox 0 347 I 3581 75.1 I 0.0461 335 I 14.01 Ox 0 I VIFx I rt1 Return Trunk Detail Table I I Trunk I Htg I Clg I Design I Veloc I Diam I H x W I Duct I I Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 1200 1200 0.046 1123 14.0 0 x 0 VinIFIx Bold/italic values have been manually overridden 2017-Jan-09 10:31:15 „ wrightsoft Right-Suite®Universal 2017 17.0.17 RSU17457 Page 2 AICA ...D1Sabatier Residence,81 Fifth St,Atl Bch.rup Calc=MJ8 Front Door faces: W wrightsoft° Duct System Summary Date: 1st FI Bdrm Ste By: Exclusively for the use of: B&G Plumbing. Heating and Air Conditioning Project Information For: Sabatier Residence 81 Fifth St,Atlantic Beach Heating Cooling External static pressure 0.10 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.10 in H2O 0.10 in H2O Supply/return available pressure 0.071 /0.029 in H2O 0.071 /0.029 in H2O Lowest friction rate 0.081 in/100ft 0.081 in/100ft Actual air flow 600 cfm 600 cfm Total effective length(TEL) 124 ft Supply Branch Detail Table I Design I Htg I Clg 'Design I Diam I H x W I Ductl Actual I Ftg.Eqv I ' Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 3 c 3137 165 166 0.081 4.0 Ox 0 VIFx 18.0 70.0 Bed 3 1 h 4918 1 2661 264 0.0881 10.01 Ox 0 1 VIFx 10.4 70.0 ( I Breakfast c 3202 169 170 0.089 8.0 Ox 0 VIFx 10.0 70.0 Return Branch Detail Table I Grille I Htg I Clg I TEL 'Design I Veloc IDiam I H x W I Stud/Joist I Duct I Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb2 Ox 0 600 600 36.0 0.081 561 14.0 Ox 0 VIFx Bc4Yita1k values have been manually overridden 2017-Jan-09 10:31:15 wrightsoft° Right-Suite®Universal 2017 17.0.17 RSU17457 Page 3 ...D\Sabatier Residence,81 Fifth St,All Bch.rup Calc=MJ8 Front Door faces: W