Loading...
1089 ATLANTIC BLVD - FIRE SPRINKLER PERMIT cIP''`� �1CITY OF ATLANTIC BEACH ' \ ' fl: f' 800 SEMINOLE ROAD 610, .. "" /' ATLANTIC BEACH, FL 32233 \ INSPECTION PHONE LINE 247-5814 MECHANICAL FIRE SPRINKLER MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 17-MCHF-2950 Job Type: MECHANICAL FIRE PERMIT Description: fire sprinkler system approved by JFRD Estimated Value: $90,000.00 Issue Date: 1/6/2017 Expiration Date: 7/5/2017 PROPERTY ADDRESS: Address: 1089 ATLANTIC BLVD RE Number: 177.616-0000 PROPERTY OWNER: Name: ASHLAND INVESTMENT, INC. Address: 7880 GATE PKWY SUITE 300 GENERAL CONTRACTOR INFORMATION: Name: SOUTH FLORIDA FIRE PROTECTION LLC Gerald Crosby, FPC14-000001 Address: 3602 29TH ST E BRADENTON FL 34208 Phone: - - FEES: Fire Sprinkler System $35.00 Total Payments: $35.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 1 - — PA C N F-3_C, kszb JOB ADDRESS: 1 0 sq 4--)-1„„-\--t (._ E 1 v PERMIT# PROJECT VALUES q D 000 ARI# REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authoXS to violate the rovisions of any other state or local law regulation construction or the performance of construction. Property Owners Name L 1 c -1-n VC S),,• F 3 Phone Number Mechanical Company SB 1. Flo t-`'/s +,l r._ P to J cc Office Phone W10,22S4ax Co. Address: `Si Il a,fk e C 4- S-,4-, - City S Grp 512h- State *7 Zip 3L/-2y0 License Holder (Print): erre GrosState Certification/Registration# -FR/Li-o 1 Notarized Signature of License llo der -7/C Ths' ?Y G� ` /�/��,°PZ°i Ac ;;t,,I JENNIFER JOHNSTON I'n _, .•, ck: MY COMMISSION k GG 042984 efore me this �^ day of U(1�1 lNkl 20 lA +„ -_-c:o EXPIRES:October 27,2020 .-s40fioD:t Bonded Tru Notary Public Underwriters ignature of Notary Public \ . Yr ,r._ , AT: . �� :--~-�� South � o id ire terotectv oro, LLC ye. .41 II Power of Attorney Agent Form- City of Jacksonville To whom it may concern, The below listed employees have my permission, Gerald Crosby, owner and license holder of South Florida Fire Protection, to submit, receive contractor ID number, sign, and pick up plans for per I' int City of Jacksonville, Florida. By: 4 At& ' Ryan Crosby By: IL c1--.\,, Andrew Rohani By: ' h'J4 Jerry Crosby-License Holder • Swor to in2;v1 my presence at Port Charlotte, Florida �1 day of ®;mace. -z„ -W,... dcr in Notary Public State of Florida, My commission expires iv—4 1 r . ,FnC.F'%9G" Amy Marie Crosby =..: 4; a'=Comrnission#FF164887 ;` ^ . Bxpire:ocr 01,2018 ,,,,,, 1ST FLORIDA NOTARY,LLC HYDRAULIC CALCULATION Fire Sprinkler Reports or4,1 Copy for • A Atlantic Self Storage 1089 Atlantic Blvd. I Atlantic Beach, FL 32233 i `�0111ffl1/�j� Digitally signed by � �0- M ��----- James M. Curt .4,?:•\.% 4" sssir:,_t is No. . Date: 2015.07.19 �1X TATEOF,�z;ttsl_ `23:27:21 -04'00 / ./)N A Al.OROV:.Ck '///SS�ONA1.`;?\ flffll Prepared By: Phillip Roe South Florida Fire Protection 9522 Melody Circle Port Charlotte,FL 33981 941-228-9541 REVIEWED 7118/15 Jacksonville PIre Prevention Div JAN 0 5 2017 0 NO EXCEPTIONS Design Area#1 ❑EXCEPTIONS AS NOTED SHEET# __- --- �� Elite Software Development,Inc. Fire-Fire Sprinkler Hydraulics Calculation Programgrtil Hydraulic Calculation i Phillip Roe Page 2 I LBurkig-ton,KY 41005 _ __- --- - - -- eeneral Project Data Report General Data - ----i Project Title: South Florida Fire Protection - Hydraulic Calculation Project File Name: Atlantic Self Storage- DA1..fiw Designed By: Phillip Roe Date: 7/18/15 Code Reference: NFPA 13 Approving Agency: Local A.H.J. Design Area#1 Client Name: Atlantic Self Storage Phone: Address: City, State Zip Atlantic Beach, FL 32233 1089 Atlantic Blvd. Code: Design Area#1 Company Name: South Florida Fire Protection Representative: Phillip Roe Company Address: 9522 Melody Circle City And State: Port Charlotte, FL 33981 Phone: 941-228-9541 Building Name: Atlantic Self Storage Building Owner: Contact at Building: Phone at Building: Address Of Building: City, State Zip Atlantic Beach, FL 32233 1089 Atlantic Blvd. Code: I Design Area#1 11 Project Data Description Of Hazard: Ordinary 2 Sprinkler System Wet Type: Design Area Of Water Application: 923 ft2 Maximum Area Per Sprinkler: 130 ft2 Default Sprinkler K-Factor: 5.60 K Default Pipe Material: SCHED 40 WET STEEL Inside Hose Stream Allowance: 0.00 gpm Outside Hose Stream Allowance: 250.00 gpm In Rack Sprinkler Allowance: 0.00 gpm Sprinkler Specifications VK300 Make: Viking Model: Size: 1/2" Temperature Rating: 155 F ,Water Supply Test Data Source Of Information: Test Hydrant ID: Date Of Test: 7/18/15 Hydrant Elevation: 0 ft Static Pressure: 50.00 psi Test Flow Rate: 1145.00 gpm Test Residual Pressure: 30.00 psi Calculated System Flow Rate: 600.21 gpm Calculated Inflow Residual Pressure: 33.44 psi Available Residual Pressure At 43.95 psi System Flow: [Calculation Project Data Calculation Mode: Demand HMD Minimum Residual Pressure: 7.00 psi Minimum Desired Flow Density: 0.20 gpm/ft2 Number Of Active Nodes: 81 Number Of Active Pipes: 93 Number Of Inactive Pipes: 0 Number Of Active Sprinklers: 14 Number Of Inactive Sprinklers: 0 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self Stdr4pedepA11448,2015,9:48 PM ;Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development Inc.ifg 'Phillip Roe Hydraulic Calculation :Burlington,KY 41005 _ fai"'iii Page 3 Fire Sprinkler Output Data • Overall Pipe Output Data _.r ,,2 j q (gpm) F. Lift Pipe-Len. Beg. Nodal Spk/Hose Residual Nom. Dia. PF-(psi) Elevation Q wpm, (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 1 8.00 30.30 25.37 10.06 1.00 25.37 0.20220 1.00 0.607 101 0.00 29.30 0.00 11.10 1.049 25.37 E 2.00 0.433 SCHED 40 WET STEEL 120 9.42 0 3.00 1.040 2 8.00 30.30 24.59 9.45 1.00 24.59 0.19082 1.00 0.572 102 0.00 29.30 0.00 10.45 1.049 24.59 E 2.00 0.433 SCHED 40 WET STEEL 120 9.13 0 3.00 1.005 3 8.00 30.30 25.29 9.99 1.00 25.29 0.20094 1.00 0.603 103 0.00 29.30 0.00 11.03 1.049 25.29 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.036 4 8.00 30.30 25.29 9.99 1.00 25.29 0.20094 1.00 0.603 104 0.00 29.30 0.00 11.03 1.049 25.29 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.036 5 8.00 30.30 25.31 10.01 1.00 25.31 0.20121 1.00 0.604 105 0.00 29.30 0.00 11.04 1.049 25.31 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.037 6 8.00 30.30 24.68 9.52 1.00 24.68 0.19208 1.00 0.576 106 0.00 29.30 0.00 10.53 1.049 24.68 E 2.00 0.433 SCHED 40 WET STEEL 120 9.16 0 3.00 1.009 7 8.00 30.30 25.50 10.16 1.00 25.50 0.20403 1.00 0.612 107 0.00 29.30 0.00 11.20 1.049 25.50 E 2.00 0.433 SCHED 40 WET STEEL 120 9.47 0 3.00 1.045 8 8.00 30.30 25.40 10.08 1.00 25.40 0.20258 1.00 0.608 108 0.00 29.30 0.00 11.12 1.049 25.40 E 2.00 0.433 SCHED 40 WET STEEL 120 9.43 0 3.00 1.041 9 8.00 30.30 24.20 9.15 1.00 24.20 0.18526 1.00 0.556 109 0.00 29.30 0.00 10.14 1.049 24.20 E 2.00 0.433 SCHED 40 WET STEEL 120 8.98 0 3.00 0.989 10 8.00 30.30 25.30 10.00 1.00 25.30 0.20114 1.00 0.603 110 0.00 29.30 0.00 11.04 1.049 25.30 E 2.00 0.433 SCHED 40 WET STEEL 120 9.39 0 3.00 1.036 11 8.00 30.30 24.17 9.13 1.00 24.17 0.18487 1.00 0.555 111 0.00 29.30 0.00 10.12 1.049 24.17 E 2.00 0.433 SCHED 40 WET STEEL 120 8.97 0 3.00 0.988 12 8.00 30.30 25.31 10.01 1.00 25.31 0.20124 1.00 0.604 112 0.00 29.30 0.00 11.05 1.049 25.31 E 2.00 0.433 SCHED 40 WET STEEL 120 9.40 0 3.00 1.037 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self StfilaipedayAlUtfvfk,2015,9:48 PM i rFire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc ' j Phillip Roe Fi" Hydraulic Calculation i Burlington,KY 41005 �`^4Page J 'Fire Sprinkler Output Data 1Overall:Pipe Output Data (cont'd) j Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. Lift Pipe-Len. pF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 13 8.00 30.30 25.38 10.06 1.00 25.38 0.20225 1.00 0.607 113 0.00 29.30 0.00 11.10 1.049 25.38 E 2.00 0.433 SCHED 40 WET STEEL 120 9.42 0 3.00 1.040 14 8.00 30.30 24.42 9.32 1.00 24.42 0.18836 1.00 0.565 114 0.00 29.30 0.00 10.32 1.049 24.42 E 2.00 0.433 SCHED 40 WET STEEL 120 9.07 0 3.00 0.998 101 0.00 29.30 0.00 11.10 1.00 0.00 0.20220 1.00 1.213 115 0.00 29.30 0.00 12.31 1.049 25.37 T 5.00 0.000 SCHED 40 WET STEEL 120 9.42 0 6.00 1.213 115 0.00 29.30 0.00 12.31 2.50 0.00 0.00859 1.20 0.045 116 0.00 29.30 0.00 12.27 2.635 51.99 F 4.00 0.000 SCHED 10 WET STEEL 120 3.06 0 5.20 0.045 102 0.00 29.30 0.00 10.45 1.00 0.00 0.19082 4.50 1.813 116 0.00 29.30 0.00 12.27 1.049 24.59 T 5.00 0.000 ' SCHED 40 WET STEEL 120 9.13 0 9.50 1.813 116 0.00 29.30 0.00 12.27 2.50 0.00 0.00263 8.90 0.034 117 0.00 29.30 0.00 12.23 2.635 27.40 F 4.00 0.000 SCHED 10 WET STEEL 120 1.61 0 12.90 0.034 103 0.00 29.30 0.00 11.03 1.00 0.00 0.20094 1.00 1.206 117 0.00 29.30 0.00 12.23 1.049 25.29 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.206 117 0.00 29.30 0.00 12.23 2.50 2.11 0.00002 5.20 0.000 118 0.00 29.30 0.00 12.23 2.635 2.11 F 4.00 0.000 SCHED 10 WET STEEL 120 0.12 0 9.20 0.000 104 0.00 29.30 0.00 11.03 1.00 0.00 0.20094 1.00 1.206 118 0.00 29.30 0.00 12.23 1.049 25.29 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.206 105 0.00 29.30 0.00 11.04 1.00 0.00 0.20121 1.00 1.207 119 0.00 29.30 0.00 12.25 1.049 25.31 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.207 118 0.00 29.30 0.00 12.23 2.50 23.18 0.00193 4.75 0.017 119 0.00 29.30 0.00 12.25 2.635 23.18 F 4.00 0.000 SCHED 10 WET STEEL 120 1.36 0 8.75 0.017 106 0.00 29.30 0.00 10.53 1.00 0.00 0.19208 4.50 1.825 120 0.00 29.30 0.00 12.35 1.049 24.68 T 5.00 0.000 SCHED 40 WET STEEL 120 9.16 0 9.50 1.825 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®ailjedaSKJUlfMr8,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation ProgramElite Software Development,Ine: Phillip Roe -►"l Hydraulic Calculation Burlirrgton,KY 41005 iiirmit Page 5 I Fire Sprinkler Output Data IOverall Pipe Output Data_(cont'd) Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 119 0.00 29.30 0.00 12.25 2.50 0.00 0.00755 9.25 0.100 120 0.00 29.30 0.00 12.35 2.635 48.49 F 4.00 0.000 SCHED 10 WET STEEL 120 2.85 0 13.25 0.100 107 0.00 29.30 0.00 11.20 1.00 0.00 0.20403 1.00 1.224 121 0.00 29.30 0.00 12.43 1.049 25.50 T 5.00 0.000 SCHED 40 WET STEEL 120 9.47 0 6.00 1.224 120 0.00 29.30 0.00 12.35 2.50 0.00 0.01617 0.75 0.077 121 0.00 29.30 0.00 12.43 2.635 73.16 F 4.00 0.000 SCHED 10 WET STEEL 120 4.30 0 4.75 0.077 108 0.00 29.30 0.00 11.12 1.00 0.00 0.20258 1.00 1.215 122 0.00 29.30 0.00 12.34 1.049 25.40 T 5.00 0.000 SCHED 40 WET STEEL 120 9.43 0 6.00 1.215 122 0.00 29.30 0.00 12.34 2.50 0.00 0.00969 2.75 0.065 123 0.00 29.30 0.00 12.27 2.635 55.46 F 4.00 0.000 SCHED 10 WET STEEL 120 3.26 0 6.75 0.065 109 0.00 29.30 0.00 10.14 1.00 0.00 0.18526 6.50 2.130 123 0.00 29.30 0.00 12.27 1.049 24.20 T 5.00 0.000 SCHED 40 WET STEEL 120 8.98 0 11.50 2.130 123 0.00 29.30 0.00 12.27 2.50 0.00 0.00335 3.50 0.025 124 0.00 29.30 0.00 12.25 2.635 31.26 F 4.00 0.000 SCHED 10 WET STEEL 120 1.84 0 7.50 0.025 110 0.00 29.30 0.00 11.04 1.00 0.00 0.20114 1.00 1.207 124 0.00 29.30 0.00 12.25 1.049 25.30 T 5.00 0.000 SCHED 40 WET STEEL 120 9.39 0 6.00 1.207 124 0.00 29.30 0.00 12.25 2.50 5.96 0.00016 5.50 0.001 125 0.00 29.30 0.00 12.24 2.635 5.96 F 4.00 0.000 SCHED 10 WET STEEL 120 0.35 0 9.50 0.001 111 0.00 29.30 0.00 10.12 1.00 0.00 0.18487 6.50 2.126 125 0.00 29.30 0.00 12.24 1.049 24.17 T 5.00 0.000 SCHED 40 WET STEEL 120 8.97 0 11.50 2.126 112 0.00 29.30 0.00 11.05 1.00 0.00 0.20124 1.00 1.207 126 0.00 29.30 0.00 12.25 1.049 25.31 T 5.00 0.000 SCHED 40 WET STEEL 120 9.40 0 6.00 1.207 125 0.00 29.30 0.00 12.24 2.50 18.21 0.00123 2.50 0.008 126 0.00 29.30 0.00 12.25 2.635 18.21 F 4.00 0.000 SCHED 10 WET STEEL 120 1.07 0 6.50 0.008 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®alleda9AJti1 M'8,2015,9:48 PM Fire-Fire Sprinkler HydaulipRs#s CalculationPq rogm', ,. .». << r i 7Ettt0oare Developi nent;.Inc. 1Phillip Roe ° r ;y zi x y •r �"^ n " ydracCaulation , .Burhngton,'K ;41005,° , . .F- . r^ , : R x ..- . _ . Page6 • Fire Sprinkler Output Data . 1 Ower 1 ik ltit'`� fi D`v a �o tl i x 4 r x• ' r, a,ri........ c. OMAN t,x:X12 r�'i. �- . •r?•_ .s.3 Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 113 0.00 29.30 0.00 11.10 1.00 0.00 0.20225 1.00 1.213 127 0.00 29.30 0.00 12.32 1.049 25.38 T 5.00 0.000 SCHED 40 WET STEEL 120 9.42 0 6.00 1.213 126 0.00 29.30 0.00 12.25 2.50 0.00 0.00618 6.20 0.063 127 0.00 29.30 0.00 12.32 2.635 43.52 F 4.00 0.000 SCHED 10 WET STEEL 120 2.56 0 10.20 0.063 114 0.00 29.30 0.00 10.32 1.00 0.00 0.18836 6.50 2.166 128 0.00 29.30 0.00 12.48 1.049 24.42 T 5.00 0.000 SCHED 40 WET STEEL 120 9.07 0 11.50 2.166 127 0.00 29.30 0.00 12.32 2.50 0.00 0.01447 7.50 0.166 128 0.00 29.30 0.00 12.48 2.635 68.90 F 4.00 0.000 SCHED 10 WET STEEL 120 4.05 0 11.50 0.166 115 0.00 29.30 0.00 12.31 2.50 0.00 0.01793 39.00 0.986 129 0.00 29.30 0.00 13.30 2.635 77.36 T 16.00 0.000 SCHED 10 WET STEEL 120 4.55 0 55.00 0.986 122 0.00 29.30 0.00 12.34 2.50 0.00 0.01946 37.25 1.036 130 0.00 29.30 0.00 13.37 2.635 80.86 T 16.00 0.000 SCHED 10 WET STEEL 120 4.76 0 53.25 1.036 129 0.00 29.30 0.00 13.30 4.00 0.00 0.00173 17.00 0.074 130 0.00 29.30 0.00 13.37 4.260 77.36 T 26.00 0.000 SCHED 10 WET STEEL 120 1.74 0 43.00 0.074 130 0.00 29.30 0.00 13.37 4.00 0.00 0.00649 14.90 0.266 131 0.00 29.30 0.00 13.64 4.260 158.23 T 26.00 0.000 SCHED 10 WET STEEL 120 3.56 0 40.90 0.266 131 0.00 29.30 0.00 13.64 4.00 134.32 0.00480 20.00 0.221 132 0.00 29.30 0.00 13.86 4.260 134.32 T 26.00 0.000 SCHED 10 WET STEEL 120 3.02 0 46.00 0.221 132 0.00 29.30 0.00 13.86 4.00 118.32 0.00379 20.00 0.174 133 0.00 29.30 0.00 14.03 4.260 118.32 T 26.00 0.000 SCHED 10 WET STEEL 120 2.66 0 46.00 0.174 133 0.00 29.30 0.00 14.03 4.00 108.29 0.00322 20.00 0.148 134 0.00 29.30 0.00 14.18 4.260 108.29 T 26.00 0.000 SCHED 10 WET STEEL 120 2.44 0 46.00 0.148 134 0.00 29.30 0.00 14.18 4.00 102.48 0.00291 20.00 0.134 135 0.00 29.30 0.00 14.31 4.260 102.48 T 26.00 0.000 SCHED 10 WET STEEL 120 2.31 0 46.00 0.134 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self Steakgleda9AltilfiWr8,2015,9:48 PM I Firelre.Sprmkler Hydraulics CalcuWtion Program ,- T Q ,e;: ,,. , I' 11 5 , 1 P Burlington,KY 41005. Fire Sprinkler Output Data Overall'Pipe Output Data (cont'd) s� .... �. ro ,.-. ..� [ = ..,a .« �f4 �39�t.,. Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len, End. KFactor Elevation Discharge Pressure Inside Dia. Q (gpm) (psi/ft) Fit-Len. PE-(psi) Node (feet) Velocity Fittings Tot-Len. PE-(psi) (K) (gpm) (psi) C-Value (fps) Type-Grp (ft) PT-(psi) 135 0.00 29.30 0.00 14.31 4.00 99.03 0.00273 18.75 0.122 136 0.00 29.30 0.00 14.44 4.260 99.03 T 26.00 0.000 SCHED 10 WET STEEL 120 2.23 0 44.75 0.122 136 0.00 29.30 0.00 14.44 4.00 95.25 0.00254 13.60 0.101 137 0.00 29.30 0.00 14.54 4.260 95.25 T 26.00 0.000 SCHED 10 WET STEEL 120 2.14 0 39.60 0.101 137 0.00 29.30 0.00 14.54 4.00 88.57 0.00222 20.00 0.102 138 0.00 29.30 0.00 14.64 4.260 88.57 T 26.00 0.000 SCHED 10 WET STEEL 120 1.99 0 46.00 0.102 138 0.00 29.30 • 0.00 14.64 4.00 77.60 0.00174 20.00 0.080 139 0.00 29.30 0.00 14.72 4.260 77.60 T 26.00 0.000 SCHED 10 WET STEEL 120 1.75 0 46.00 0.080 139 0.00 29.30 0.00 14.72 4.00 60.89 0.00111 20.00 0.051 140 0.00 29.30 0.00 14.77 4.260 60.89 T 26.00 0.000 SCHED 10 WET STEEL 120 1.37 0 46.00 0.051 140 0.00 29.30 0.00 14.77 4.00 39.50 0.00050 14.70 0.020 141 0.00 29.30 0.00 14.79 4.260 39.50 T 26.00 0.000 SCHED 10 WET STEEL 120 0.89 0 40.70 0.020 141 0.00 29.30 0.00 14.79 4.00 19.57 0.00014 9.10 0.005 142 0.00 29.30 0.00 14.80 4.260 19.57 T 26.00 0.000 SCHED 10 WET STEEL 120 0.44 0 35.10 0.005 121 0.00 29.30 0.00 12.43 2.50 0.00 0.02811 32.33 1.359 143 0.00 29.30 0.00 13.79 2.635 98.66 T 16.00 0.000 SCHED 10 WET STEEL 120 5.80 0 48.33 1.359 128 0.00 29.30 0.00 12.48 2.50 0.00 0.02536 36.25 1.325 144 0.00 29.30 0.00 13.81 2.635 93.32 T 16.00 0.000 SCHED 10 WET STEEL 120 5.49 0 52.25 1.325 143 0.00 29.30 0.00 13.79 6.00 0.00 0.00039 17.00 0.021 144 0.00 29.30 0.00 13.81 6.357 98.66 T 38.00 0.000 SCHED 10 WET STEEL _ 120 1.00 0 55.00 0.021 131 0.00 29.30 0.00 13.64 2.50 23.90 0.00204 101.10 0.239 145 0.00 29.30 0.00 13.88 2.635 23.90 T 16.00 0.000 SCHED 10 WET STEEL 120 1.41 0 117.10 0.239 144 0.00 29.30 0.00 13.81 6.00 0.00 0.00132 14.90 0.070 145 0.00 29.30 0.00 13.88 6.357 191.98 T 38.00 0.000 SCHED 10 WET STEEL 120 1.94 0 52.90 0.070 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®ateda¢fULtfiv(8,2015,9:48 PM Fire=Fire Sprinkler Hydraulics Calculation Program: 0 Elite SoftwareDevelopment,Inc. Phillip Rce.. �. Hydraulic Calculation; Burlington,KY'44005 rir"i ;, . _ Page 8, Fire Sprinkler Output Data - Q_vOi:glipi koutput pAtailooned-� k . ,. .. ; f, m ;`"' ., , „ 1 ...ax.: rr,-, (5!? r.ii�,»+�...�a • .. _ ��!�n,�k'c�`` .. .u` .. .��,r Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. Lift Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) (feet) VelocityFittings Tot-Len. Node (K) (gpm) (psi) C-Value (fps (ft) PT-(psi) 132 0.00 29.30 0.00 13.86 2.50 16.00 0.00097 101.10 0.114 146 0.00 29.30 0.00 13.97 2.635 16.00 T 16.00 0.000 SCHED 10 WET STEEL 120 0.94 0 117.10 0.114 145 0.00 29.30 0.00 13.88 6.00 0.00 0.00164 20.00 0.095 146 0.00 29.30 0.00 13.97 6.357 215.89 T 38.00 0.000 SCHED 10 WET STEEL 120 2.18 0 58.00 0.095 133 0.00 29.30 0.00 14.03 2.50 10.03 0.00041 101.10 0.048 147 0.00 29.30 0.00 14.08 2.635 10.03 T 16.00 0.000 SCHED 10 WET STEEL 120 0.59 0 117.10 0.048 146 0.00 29.30 0.00 13.97 6.00 0.00 0.00187 20.00 0.109 147 0.00 29.30 0.00 14.08 6.357 231.88 T 38.00 0.000 SCHED 10 WET STEEL 120 2.34 0 58.00 0.109 134 0.00 29.30 0.00 14.18 2.50 5.81 0.00015 101.10 0.017 148 0.00 29.30 0.00 14.20 2.635 5.81 T 16.00 0.000 SCHED 10 WET STEEL 120 0.34 0 117.10 0.017 147 0.00 29.30 0.00 14.08 6.00 0.00 0.00203 20.00 0.118 '148 0.00 29.30 0.00 14.20 6.357 241.92 T 38.00 0.000 SCHED 10 WET STEEL 120 2.45 0 58.00 0.118 135 0.00 29.30 0.00 14.31 2.50 3.45 0.00006 101.10 0.007 149 0.00 29.30 0.00 14.32 2.635 3.45 T 16.00 0.000 SCHED 10 WET STEEL 120 0.20 0 117.10 0.007 148 0.00 29.30 0.00 14.20 6.00 0.00 0.00212 20.00 0.123 149 0.00 29.30 0.00 14.32 6.357 247.73 T 38.00 0.000 SCHED 10 WET STEEL 120 2.50 0 58.00 0.123 136 0.00 29.30 0.00 14.44 2.50 3.78 0.00007 101.10 0.008 150 0.00 29.30 0.00 14.44 2.635 3.78 T 16.00 0.000 SCHED 10 WET STEEL 120 0.22 0 117.10 0.008 149 0.00 29.30 0.00 14.32 6.00 0.00 0.00217 18.75 0.123 150 0.00 29.30 0.00 14.44 6.357 251.18 T 38.00 0.000 SCHED 10 WET STEEL 120 2.54 0 56.75 0.123 137 0.00 29.30 0.00 14.54 2.50 6.69 0.00019 101.10 0.023 151 0.00 29.30 0.00 14.56 2.635 6.69 T 16.00 0.000 SCHED 10 WET STEEL 120 0.39 0 117.10 0.023 150 0.00 29.30 0.00 14.44 6.00 0.00 0.00223 13.60 0.115 151 0.00 29.30 0.00 14.56 6.357 254.96 T 38.00 0.000 SCHED 10 WET STEEL 120 2.58 0 51.60 0.115 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self Steda9A11448,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program �J Elite Software Development,Inc.'' I Phillip Roe "�"�l Hydraulic Calculation Burlington,KY 41005 Page 9 Fire Sprinkler Output Data Vera!! Pipe Output Data (cont'd) f `' Beg. Nodal Spk/Hose Residual Nom. Dia. q (gpm) F. L./ft Pipe-Len. PF-(psi) Elevation Q (gpm) (psi/ft) Fit-Len. End. KFactor Discharge Pressure Inside Dia. PE-(psi) Node (K) (feet) (gpm) (psi) C-Value Velocity Fittings Tot-Len. PT-(psi) (fps) Type-Grp (ft) 138 0.00 29.30 0.00 14.64 2.50 10.96 0.00048 101.10 0.056 152 0.00 29.30 0.00 14.70 2.635 10.96 T 16.00 0.000 SCHED 10 WET STEEL 120 0.64 0 117.10 0.056 151 0.00 29.30 0.00 14.56 6.00 0.00 0.00234 20.00 0.136 152 0.00 29.30 0.00 14.70 6.357 261.64 T 38.00 0.000 SCHED 10 WET STEEL 120 2.64 0 58.00 0.136 139 0.00 29.30 0.00 14.72 2.50 16.71 0.00105 101.10 0.123 153 0.00 29.30 0.00 14.84 2.635 16.71 T 16.00 0.000 SCHED 10 WET STEEL 120 0.98 0 117.10 0.123 152 0.00 29.30 0.00 14.70 6.00 0.00 0.00253 20.00 0.147 153 0.00 29.30 0.00 14.84 6.357 272.60 T 38.00 0.000 SCHED 10 WET STEEL 120 2.76 0 58.00 0.147 142 0.00 29.30 0.00 14.80 2.50 0.00 0.00141 101.10 0.165 154 0.00 29.30 0.00 14.96 2.635 19.57 T 16.00 0.000 SCHED 10 WET STEEL 120 1.15 0 117.10 0.165 141 0.00 29.30 0.00 14.79 2.50 19.93 0.00146 101.10 0.171 155 0.00 29.30 0.00 14.96 2.635 19.93 T 16.00 0.000 SCHED 10 WET STEEL 120 1.17 0 117.10 0.171 154 0.00 29.30 0.00 14.96 6.00 0.00 0.00002 9.10 0.001 155 0.00 29.30 0.00 14.96 6.357 19.57 T 38.00 0.000 SCHED 10 WET STEEL 120 0.20 0 47.10 0.001 140 0.00 29.30 0.00 14.77 2.50 21.40 0.00166 101.10 0.195 156 0.00 29.30 0.00 14.97 2.635 21.40 T 16.00 0.000 1 SCHED 10 WET STEEL 120 1.26 0 117.10 0.195 155 0.00 29.30 0.00 14.96 6.00 0.00 0.00007 14.70 0.004 156 0.00 29.30 0.00 14.97 6.357 39.50 T 38.00 0.000 SCHED 10 WET STEEL 120 0.40 0 52.70 0.004 153 0.00 29.30 0.00 14.84 6.00 0.00 0.00282 8.20 0.130 157 0.00 29.30 0.00 14.97 6.357 289.31 T 38.00 0.000 SCHED 10 WET STEEL 120 2.92 0 46.20 0.130 156 0.00 29.30 0.00 14.97 6.00 0.00 0.00016 11.90 0.008 157 0.00 29.30 0.00 14.97 6.357 60.89 T 38.00 0.000 SCHED 10 WET STEEL 120 0.62 0 49.90 0.008 157 0.00 29.30 0.00 14.97 6.00 0.00 0.00402 2.33 0.082 158 0.00 29.30 0.00 15.05 6.357 350.21 E 18.00 0.000 SCHED 10 WET STEEL 120 3.54 0 20.33 0.082 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self Steakgleda9AfLljiv68,2015,9:48 PM Fire-Fire Sprinkler Hydraulics Calculation Program � Elite Software Development,Inc;; Phillip Roe 1 Hydraulic Calculation Burlington,KY 41005 ritiroli Page 1.0. jFire Sprinkler Output Data __ 1 Overall Pipe Output Data (cont'd) q (gpm) F. L./ft Pipe-Len. PF-(psi) Beg. Nodal Spk/Hose Residual Nom. Dia. Q (gpm) (psi/ft) Fit-Len. Elevation PE-(psi) End. KFactor Discharge Pressure Inside Dia. (p ) Node (K) (feet) (gpm) Velocity Fittings Tot-Len. m (psi) C-Value (fps) Type-Grp (ft) PT-(psi) 158 0.00 29.30 0.00 15.05 6.00 0.00 0.00402 20.00 0.153 159 0.00 9.30 0.00 23.87 6.357 350.21 E 18.00 8.660 SCHED 10 WET STEEL 120 3.54 0 38.00 8.813 159 0.00 9.30 0.00 23.87 6.00 0.00 0.00402 8.50 0.179 160 0.00 9.30 0.00 24.05 6.357 350.21 2E 36.00 0.000 SCHED 10 WET STEEL 120 3.54 0 44.50 0.179 160 0.00 9.30 0.00 24.05 6.00 0.00 0.00402 11.30 0.813 161 0.00 1.00 0.00 28.45 6.357 350.21 F2T2B2C 191.00 3.594 SCHED 10 WET STEEL 120 3.54 0 202.30 4.407 161 0.00 1.00 0.00 28.45 6.00 0.00 0.00438 17.00 0.238 162 0.00 -4.00 0.00 30.86 5.890 350.21 2E 37.20 2.165 CAST IRON, CEMENT 140 4.12 0 54.20 2.403 162 0.00 -4.00 0.00 30.86 6.00 0.00 0.00354 68.00 0.465 163 0.00 -4.00 0.00 31.32 5.993 350.21 3E 63.30 0.000 PVC, CLASS 200 150 3.98 0 131.30 0.465 163 0.00 -4.00 0.00 31.32 6.00 0.00 0.00438 8.50 0.119 164 0.00 2.00 0.00 28.84 5.890 350.21 E 18.60 -2.598 CAST IRON, CEMENT 140 4.12 0 27.10 -2.479 r 164 Backflo 2.00 28.84 350.68 Prey 165 3.00 psi 2.00 31.85 165 0.00 2.00 0.00 31.85 6.00 0.00 0.00438 8.50 0.200 166 0.00 -4.00 0.00 34.65 5.890 350.21 2E 37.20 2.598 CAST IRON, CEMENT 140 4.12 0 45.70 2.798 166 0.00 -4.00 0.00 34.65 6.00 0.00 0.00354 76.00 0.521 167 0.00 0.00 0.00 33.44 5.993 350.21 ETG 70.90 -1.732 PVC, CLASS 200 150 3.98 0 146.90 -1.211 Fitting Legend: F=45 Degree Elbow, E= 90 Degree Elbow, L= Long Turn Elbow,T=Tee or Cross, B=Butterfly Valve, G= Gate Valve, C= Check Valve C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®a eda9AlliL l*8,2015,9:48 PM Fire-Fire Sprinkler HHydraulics Calculation ProgramSoftware _ - -- Elite Softwar F Hydraulic Calculation alculation LBPuhrillliinpgRtooe KY 41005 l'-' Page 11.1 ' Fire Sprinkler Output Data LOverall S rinkler Output Data Flowing Area Group Sprinkler Sprinkler Residual Flowing Flowing Sprinkler Sprinkler Code KFactor(K) Elevation Pressure Area (ft') Density Discharge Node No. (feet) (psi) (gpm/ft2) (gpm) 1 8.00 30.30 10.06 120.00 0.211 25.37 Sub Totals For Non-Group 120.00 0.211 25.37 2 8.00 30.30 9.45 123.00 0.200 24.59 Sub Totals For Non-Group 123.00 0.200 24.59 3 8.00 30.30 9.99 120.00 0.211 25.29 Sub Totals For Non-Group 120.00 0.211 25.29 4 8.00 30.30 9.99 115.00 0.220 25.29 Sub Totals For Non-Group 115.00 0.220 25.29 5 8.00 30.30 10.01 120.00 0.211 25.31 Sub Totals For Non-Group 120.00 0.211 25.31 6 8.00 30.30 9.52 115.00 0.215 24.68 Sub Totals For Non-Group 115.00 0.215 24.68 7 8.00 30.30 10.16 120.00 0.212 25.50 Sub Totals For Non-Group 120.00 0.212 25.50 8 8.00 30.30 10.08 100.00 0.254 25.40 Sub Totals For Non-Group 100.00 0.254 25.40 9 8.00 30.30 9.15 45.00 0.538 24.20 Sub Totals For Non-Group 45.00 0.538 24.20 10 8.00 30.30 10.00 80.00 0.316 25.30 Sub Totals For Non-Group 80.00 0.316 25.30 11 8.00 30.30 9.13 54.00 0.448 24.17 Sub Totals For Non-Group 54.00 0.448 24.17 12 8.00 30.30 10.01 80.00 0.316 25.31 Sub Totals For Non-Group 80.00 0.316 25.31 13 8.00 30.30 10.06 83.00 0.306 25.38 Sub Totals For Non-Group 83.00 0.306 25.38 14 8.00 30.30 9.32 45.00 0.543 24.42 Sub Totals For Non-Group 45.00 0.543 24.42 Totals For All Groups 1320.00 0.265 350.21 C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self Staallleda9At ilfM'8,2015,9:48 PM j Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc ' i Phillip Roe Hydraulic Calculation Burlington,KY 41005 � � Page 12 [Fire Sprinkler Output Summary [Hydraulically Most Demanding Sprinkler Node -� HMD Sprinkler Node Number: 11 HMD Actual Residual Pressure: 9.13 psi HMD Actual GPM: 24.17 gpm Sprinkler Summary sr Sprinkler System Type: Wet Specified Area Of Application: 923.00 ft2 Minimum Desired Density: 0.200 gpm/ft2 Application Average Density: 0.379 gpm/ft2 Application Average Area Per Sprinkler: 65.93 ft2 Sprinkler Flow: 350.21 gpm Average Sprinkler Flow: 25.01 gpm Flow Velocity And Imbalance Summary _ Maximum Flow Velocity ( In Pipe 107 - 121 ) 9.47 ft/sec Maximum Velocity Pressure ( In Pipe 107 - 121 ) 0.60 psi Allowable Maximum Nodal Pressure Imbalance: 0.0100 psi Actual Maximum Nodal Pressure Imbalance: 0.0076 psi Actual Average Nodal Pressure Imbalance: 0.0003 psi Actual Maximum Nodal Flow Imbalance: 0.4770 gpm Actual Average Nodal Flow Imbalance: 0.0118 gpm Overall Network.�Summary • Number Of Unique Pipe Sections: 93 Number Of Flowing Sprinklers: 14 Pipe System Water Volume: 1277.07 gal Sprinkler Flow: 350.21 gpm Non-Sprinkler Flow: 0.00 gpm Demand Flow Excluding Exterior Hose Flow: 350.21 gpm Exterior Hose Flow: 250.00 gpm Minimum Required Residual Pressure At System Inflow 33.44 psi Node: Demand Flow At System Inflow Node: 600.21 gpm C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self SteaIgecialpAlL*48,2015,9:48 PM - Fire-Fire Sprinkler Hydraulics Calculation Program Elite Software Development,Inc. Phillip Roe Hydraulic Calculation Burlington,KY 41005 Page 131 Fire Sprinkler Output Data .Hydraulic_Supply/Demand Graph 100 I I 90 80 U) 70 a 60 z 50 N a 40 • 30 30 7 20 • 10 0 2 4 6 8 10 12 14 16 18 20 Flowrate(x1 00) gpm Supply Curve Data Static Pressure: 50 psi Test Residual Pressure: 30 psi Test Flow Rate: 1145 gpm Demand Curve Data Calculated Residual Pressure: 33.44 psi Calculated Flow Rate: 600.21 gpm Exterior Hose Flow: 250.00 gpm Excess Available Residual Pressure At Calculated Flow: 10.51 psi Pressure Required For First Sprinkler Downstream From Inflow Node To Flow: 16.12 psi C:\Users\Phillip\Documents\Elite Software\Fire 6 Projects\South Florida Fire Protection-Atlantic Self St®a ieda9AJ1j *8,2015,9:48 PM ,r r : ..:.::...:. , , Schedule , .Q an •Schedule 40 . .-',. ...:., :•.- .„...-_, ..,.•:,,,.„-.i:::,...7...... •.: ...: „...:,...•..,.. ' �n .Lt .-* )h-rr1' ii.yY" lj D..ef �"...r . .;,-,-;:‘• --. - . - : • ••";:,•• . .......:.„..:.. .yr .•. - • FM Approved and UL Listed Sprinkler Pipe FILE t f Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and for U.S. made to ASTM A135 and ASTM A795 These Schedule 40 are FM Approved and UL Listed. (for products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems In accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same _rigorous testing as our ASTM withthe zinc coating specifications of ASTM A795 or A53. other fine pipe products. Schedule 10 Pipe • .5 rji rtf o 'tIK �(r .iK``'3 Mt r. 1 � . 1.315 v t1s:zC3 z4F-.� tti.�.e 7 "_ �1�� r!":. 1 1/4 1.097 1.41 lbs/ft 91 1.660 1.442 1.81 lbs/ft 61 1 1/2 1.900 2 1.682 2.09 Ibslft • 2.375 2.157 61 2 1/2 2.875 2 2:64 Ibstft 37 3 .635 3.53 lbs/ft 30 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 Schedule 40 Pipe 1 1.315 � �• t r+. � 41,...*V 1 1/4 1.049 1.68 lbs/ft 1.660 70 1 1/2 1.380 2.27 lbs/ft 51 1.900 1.610 2.72 lbs/ft 44 2 2.375 2 1/2 2.067 3.66 lbs/ft 2.875 2.468 30 3 3.500 3 5.80 (bs/ft 30 4 .068 7.58 lbs/ft 19 4:50U 4.260 10.80 lbs/ft 19 For proper operation,all pipe surfaces should be cleaned prior to installationinstallation In PREPARATION to provide a leak light seat for thegasket, -be free from Indentations and projections from the end of the pipe to the groove All loose paint,scale,dirt,chips,grease,and rust must be removed pdor to irtstallatloR. Failure to takcthese• pipe surfaces should be 1. instructions for the specific fitting used. may result in(rnproper coupling assembly,causing leakage. Also,check the manufacturer's ----- - r es Arai 1819 Clarkson Road =or additional information, y/�r Chesterfield,MO 63017 contact your salesperson c UL , t aut.,.MOOSE TUBE COMPANY (8°13)325-4 467 today at(800)325-4467 or o T V FAX:(636)•537.2645 (636)537-2600 In the USA, - v'�n'-:'•,n ^anti,- or tram Canada A�� company e mail:uhcr!1'ii_o it'__"_cot.1 call(800)882-4666 41/: _ NI informs•'on contained Herein is accurate as known Si the t;me of publ canon Buil Moose Tube reserves the n ht to change APPROVED 9prodocf tpedficafiona without notice and without fntumng obligation '1108 7. r , '• , , 1l -� it.e ct`5.' . •'I ,7/9:i t' 4i- -,A1 - ,41-'% ,---;r', ..�,:t J '- N GS Hole-Cut System MODEL V-M22 MECHANICAL TEE, GROOVED-END OUTLET The VGS Model V-M22 mechanical tee provides a fast and easy ` "k; mid-pipe ,"' gr0oved-end branch 0utlet. The groove dimensions o -�� r; ';7_ conform to AWWA C606.UUFM working 1 It"' g pressure is rated 300 I I z!...:„.,"';a,„ '•:, psi(20 bar). , , �' j ay+.:.:' _:; , ii Him OV1. 11:1111110. 11 dik �1 �I,rl �:i$.rV C)$ ( \- ' !ill s a tF i . .1cr:. ,,,,,,.- LISTED -,:� ' APPROVED N.4.0 six. I RM I Holt 04. RueShe Welke m� mOr_O, •S2-0r 40.4 i A--r-• °a» - -- Baa 80X40 889X48 3 �S~ 90.5 ._._...�^'M __'L"572 mw4wa a'^7 X 7 3 X 15 3500 X 1900 200 23 7 1572 96 0 112 X 35 .74 90.5 532209 _ 080 80%SO 3e.9 X 603 64 � 90.5 6.19 1/2 X l 3.74 3 X 2 3.500X2.373209 6.19 4.25 M12 XIS 1.03 - _ ...� 2.50 3.56 2.09 6.19 4dS 100X40 1143X16] 51 i32 X 7 sol 4 X 15 921 66.7 I 181.6 1016 _I 4.500 X 1.900 2.00 363 -- Mt2 X 7S 181 1001 SO Ir 3143X603 263 1.39 1014 1/2X7 64 101.6 667 182.6 1 98 4 X 2 4300X2.375 2.30 r 101.6 MX7S 1.97 - l00 X 65 114 3X7].0 4.00 _ 2.63 719 4.00 70 ' 103.6 1/2 X 3 2.66 1 X 23 4500 X 2.e75 267 17 4 44 V2 X 75 4.002.66 100X80 1143X889 89 'I 263 7.19 4.N V2X3 5-e5 4%l. 1040 667 382.6 328.6 1412 X 75 4.000X3.500 3.50�.._,j 413 1 2.� )41 RSXSO 143.7X60.7 3 64 Ij 719 I 3.06 V2XJ 5„30 t 120.7 51.0 223-~ li-- 106.4 _ 5 X 2 5563 X2 375 2.50 I 4.75 116 X 90 5.63 125X65 f esti X730 7p� 1.19 LOt 4.19 SM 120.7 5,79_ S X 25 S 56JX 2.875 ! _ 2 7S 4.75 �1�� 273.8 112.7 M16 X 90 --2 88 ISO X50 t 168_3%603 64 1702 8.� -__ 44.1 r S/OX3•1/2 634 9LS 106.4 6 X 2 6.623 X 2.375 1 230 � 513 1 I 9.67 MtX3 1901 6.12 150X65 1693X71.0 1 70 3.72 10. __ 419 5/86X90 6.12 ; 130.2 91.5 6 X 23 ... I 6.625 X 1875 2 75 2587 j 112.7441 M16 X 90 3.73 708 -ISO X 80 I '663 X 88.9 = --�-i- SIS-' 3'77 _ 9.R7 I 444 _ _57B X 3.1/2 89 130.2 - L68 _ 68 6 X 3 I 6.625%3.500 I913 2508 1U.8 � M16X90 3SO 313 772 8.30 150 X 300 I 168_3 X 111 3 907 5.19 61 6X 3.1/2 4.055 114 1373 9t.S LSO.B I t r 6%4 1 6,625 X 4300 I 430 � 1 SB.B Mt6 X 90 5.40 1 3.72 I 9.87 6.25 518 X 3.1/2 I Hole diameters listed are wrgaetted hal*saw diamete8.91 11 `•PI .\ 1j<ITrusted above all TM •..1.,,,,,,:44:F....?,.., a}{ S:f�i"%4 _5�•f'? .tc,{r!,LtY..:�l._{p,.• ."'.1.2:'. y I .. . . .J... x .1\~ �:'rl y. ,;air nr..,.., S.-•a-•'.,.t,q�ea yt.4&'4' L TS Nif GS ' Grooved Fittings MODEL V-901 SHORT RADIUS 90° ELBOW MODEL V-903 SHORT RADIUS TEE •D U` US ,•%,—•.•!.21.. CE :/:: LISTED 11 fir.;• APPROVED Nominal Slee Pipe V-901 mm/In O.D. SR 90 Elbow V-903 mmdn SR Ural•ht Tee SO rC�E(mm/In) K• 2 601 70 ® K•s/Lba 6S 2.773 _I 2.75 13 I 70 10 IS 2.S 770 76 2.73 22 6f 2875 ].Oe 09 76 11 76.1 76 09 17�__._, 29 80 — 11 43 1� e0 20 WO ---- i lie 6 ns 1 '�i86—T. la t.le 17 • �� — I 6soo tot 7.6 _ 2s 4.00 S 161] t71 f_ 7 7 6.00 79 ISO 3361 stltl 7S 126 � 66 I6S.1 0 27 6•eB 707 SS i 160 86 Ise 6 SSO 166.] 140 t2— •- — 200 6.625 S S 140 1 ee 8 719.T A6e..2 6.06 I 770 376 tee E76 16S 24.3 1 6.94 16.1 , I �l 4 - Oik. 0 (. I ( ` lek -- C"....74...... ."... - 1 3I/9'. ) / vit , 1 'Alto available MO ha dp zinc galvanued fn,eled(optional) Trusted above a11.7A6 \Jim%20 • i,i.1"5d..'7-rs..-•"4.1-...'4.,4;r a.7.VM t 01!11.4.}>:"1 .*ni a y •,'}4-4, '1, �3�..;rr �Y +�7r. yl ,NiGsi. Grooved Fittings MODEL V-7160 END CAP I i' -1-4.5;?,,,:.::..‘..`'''' s, 1.,::::::.:,........._.;.,..,...,CLIUS 111011110. j17LISTFO APPAOVEU ® V-7260 End Cap 1•I/4"- 12" wv.00, mm/In min/In Kgs/Lbs 12 42.2 1.25 1.660 04 40 46J 0 2 zs o: ,,s 1.900 1.00 4 s0 I 60.1 -- 3 2 0.25 0 3 2.373 1.00 65 73 0 0.7 63 230 0.6-- 65 761 OA 0.• 1111-111E11.— 111111 07 100 108.0 I'S zs 11 • 4.230 400 171 p1.3 _ 1 7 .0 t 7 3 5.363 1.00 ISO 1683.0 43 ]6 6 6.625 .000 6.6 IS0 1651 25 , 3.0 _ .1 _ 200 219 e30 5.5 4.623 418 .1 730 2730 32 7.z0 10 10.730 1.25 3004 103 0 123.9 12 12.750 2S- ' 100 • 220 Also 6.41404 toth 1101 Op Sine galvuv$ed rinifhed 6301107120 Trusted above aII.TM II(ING 18 t _'[ `Y�'-.} 3.,7t.4„e14 R! yKM1.s l:11i'..:>r'` • 0'" '.4;1,m441, �7 a. V Gs rhi Grooved Fittings MODEL V-7120 TEE MODEL V-7135 CROSS VGS grooved fittingsi''s 1.3'; are cast of ductile hon. i';',.'7:-..-:,,i.; I, i C �L us FM :r 1. • 1f- R9.vnzo r.� 71g.V•7135 Gou Fig.V-7135 LISTED APPROVED 5.I Gods pe V-7120 O.D. �M V• s UM mm/tn Cross 32 42.2 70 3 •_ 125 L660 O'l.bs �_ K•s/tbs I2 �_ 275 1.S 70 1.2 IS 6t] 4.... 70 70 22 SO 1900 L75 00 70 1 65 ]25 7 9.11 2373 , 7 73 603 13 1,3 93 12 ZS 7]0 2075 2. 22 9S ]0 65 761 6 II 3.75 v3 2 67 s0 95 50 3MEM 100 ' 01 ... 1pp 6.25 6. .25 1.1 1143 6.25 6a 6 4 500 . 127 123 S7 s 161.3 �� II.s S.s63 ISO ' MSS 163100 I _ I50� 6.625 450 220 I ids 120 _ 1651 1 165 I 93 650 320 "—�_ _.„� 165 113 200 219.1 I •.. ... 197 8.625 7.75 NMI 197 20.00 7.73 641 'Alto avada0k 10111 ha dip arc galvanised 7lnaled(Optional) NIIKIN Trusted above all.T"' 15 4 • � irN• • 1 . :'";1.41; .w: .•.,y(i ` i ! { 1`4aS. .f.aaf27R" 4x .i to r ,, . 'T .._71.1. . 1:ti 471;; ij ..1 \ISTM Grooved Fittings GROOVED ELBOWS . MODEL V-7110.90° ELBOW MODEL V-7111 45°ELBOW MODEL V-7112 22-1/2° ELBOW MODEL V-7113 11_1/ ° ... 4 ELBOW /" VGS grooved fittings are cast of ductile Iron. C E 'r-" 112 .1-4.7v:: 5 C-E: -fir':: Fig 7112 1111111)00' 7113 72.1/2'Elbow Fl4 Elbow C®us 11 1/4'Elbow LISTED APPROVED z LI 0 , 4-34.'.' Fig.7110 _ Elbow R9.711, fig 7113 45'Elbow 11-1/4'Elbow Nominel pipe V-7110 Site O.D. 90'Elbow V-7111 V-7112 nml/In mTrr741 -� 4S Elbow 9 1lLba C 22-1/2'Elbow 422 °5 4S - k• Lbs ' K• ��r>•or.� 40 48)1.660 tl 677 07 45 0.3 5 E=L=]..1■ 70 07 17Sein IS 1.900 2.73 4S .7 Q/ 1.18 MN 2° 603 07 0.9 t 75 0.9 1.75 1.3 08 3S 0.3 2.375 3250 07 18 178 1 07 65 77.0 .. �2 .� i s °° 75 2S 2675 95 • 12 57 18e_ 138 6S 761 Y9S 2.6 2.25 2ME 501 1.0 38 1.0 -- - 14 S7 t0 51 2.2 LSO 22 d0 88 9 108 - _ 1 1.0 ]e 1.0 2.0 64 1 7 14 - r11] 317x° _ . 4.25 47.• _ 250 29 I S7 1.1 78 aim { '�- 3°0 5.00 -•--�76 20 �3 22 O__- 4130 62 45 123 I41� 1.0 62 300 44 2.88 44 L7S MN 5567 550 110 ® )S ISO 168.) I6$ 77 - ... "' ' 6 I 6625 64 89 _-41 -. dS0 141 79 SO ISO 1651 165 S 7 ---1-l sem-- 9 7 7.12 110 SI )4 89 4.4 79 :00 7.5 200 2191 197 12.3 108 - 1 ].4 NW 8.625 7.75 90 - - 2770 �' 275 425 19.1 31 24 0 121 170 2.00 Miliall 10 750 9 00229 228 121 -- Mill MODEL V 7110DR DRAIN ELBOW 374 _ The Model V-7110DR is a grooved end ductile iron cast elbow with �" an integral 1" NPT or BSP drain. The V-7110DR was primarily ]o r`„ ' 'mm�/In K 2.3 designed for,but not limited to,use on fire protection standpipes. 603 95 372 12 2 2375 3.27 2 2S -=ci 65 770I3 1 70 ` L?: 23 2875 3.75 17 2 7s iINII 211 76.1 95 70 40 13 ao i 889 toe ,_ ` 70 19 �' + i r 3.__ I 3.500 4.25 2.75 1.97 2.0 ,` ..1 100 i ..114 3 127 70 63 {4 4 )O .r/u'r• ......___4... .,1a0- 5.00 3.75 2 48 C UL US ISO 1651 --- _ _ 6.6 165 70 90 7.0 I50 1 1687 165 70 90 70 OSTED Ai-W -0 - 6 6625 630 275 334 is 200 219.1 192 '311040138171e mat 1101 dl 114 12.7 p 75rK g+1w192rd fn�lnrd Iepuona0 8 ; 8673 ' 7.76 3.27 119 27 Trusted above all TM NIKgG14 • . . .. NGsr. Grooved Couplings MODEL V-7706 REDUCING COUPLING The VGS Model V-7706 reducing coupling allows for direct reduction on a • �� 1 r piping run and eliminates the need for a concentric reducer and r• :tV The specially designed rubber " , telescoping Into larger pipe gasket helps Prevent small couplings, 9 during vertical assembly. pipefrom f .' Caution.The Model V-7706 couplings should not be as the end cap may be sucked into the pipe when drainingwithd an end cap, 1% UL BS 9 the system. ri -1.' '`...--;.:-/. .,f;. 100 LISTEDAPPROVED 1 - • :1: h.. 4.III ,.._ •• Mil:• ` . + .i t . 1 Nominal 2'-1r . ; ` Slee Ca Max.Working Max.End Axial nSIx* mm/in Pfessure Load Displacement Per Coupling Dimensions SOm x 40 603x482 gar/PSI pNng - k/4/Lisa n1mRn Pel PO De roe i9 minim IMR C 24 4.40 Belt 55 Weight 2xli 2)75x1.9000-]2 "' . ./. ..1. , /, 350 1336 3•.02• 26.0 2s 122 6Sa5O 7]0x60] O-4q 4. MtOx5S 315 09 2.3 x 2 2 676x2.375Let 46 3/6 a z•ve 22.0 96 I 20 65:30 76.1■60] 144 12 MIO xSS 24 036 Ill __ 3.78 S 67 tee -• 71.0 1/8® ill .- 80:50 811.9 x 603 2'•24' 102 I '30 IB 111M111112x2 7SOOx 2373 6.83 0-12i 18.0 Na63 1149x7]0 550 1370 0-013 2'•04' 23 116 168 411 M12475 1111 7x2.3 7.SOOx 2873 350 24 1001 0.7.2 040 457 6.61 169 it x3 3]70 2••04' 116 4B M12 x 73 80 a 65 .,. O_013 - 168 lall 24 10.91 022 17 0-32 457 661 189 In al _ 2.,a. 180 116 IN 'moi 37 100 x so 114.3 x 60.3 - ! 42 ,•2 24 683 0-4.11 - - _ Ia: 4.s00x2J7s iso -• - SS60 2•.04• 210 75 1911 __. iii, 100x65 1143x770 O-OH 52 Mt26 75 2.4 24 1004 025 _S.75 (7.10 96 1 x 71 I.SOO s 2.8750-I.B 1 21.0 2.08 U2 x 3 SJ • - 350 I 5360 0-019 2'•24' 025 116 198 52 t143a 761M12x7S 21 24 1091 0-4.8 -2 24 546 7.80 20 S 21.0 I I/7 x 3 S.7 (00x80 114.34089 - 2'•21' i 116 191 S2 MEI 24 14.89 0-4 8 -• 4 a 3 4 500 x 3300 350 33602•,21, 21.0 146 198 ISOx q0 165.1-1I4J •" 0-0.19 025 S2 M12 x75 Bill 2a 24 61 0.61 5.75 7.80 2.03 20 0 I/2 x 3 150>t r00 - 2*-11• 202 269 52 MI6 x 90 1627x1113 ... 45 2461 0-64 6 x 4 a 625 x 4.500 12040 2',12' 19 0 ( 208 _ -, 200 a 150 0-0.25 27S 52 M1a x90 4.5 2/91 x IN3 21 023 I 819 10 a1 8x6 SI 2 1 2625x6623 350 0_64 ISO 2.05 1/2 99 ® 219.1 x 166.120440 0_0.23 I I._.10' 260 313337 M20 C 4 24 0187.6 Sl]S o-64 1021 t3.13 224 4-3/47/4x 13 0 260 16 7 OMectkln or an ulae mov El - - • ••.4O• ._ 134 57 M20 x t20 9 einem Is the maximum value Mat a coupling allows under no Interne/pressure - ... _. ••- '/430 evadable with hp cep Zinc 9alanized rnnhed(Ophonall Trusted above all.TM 13 dl/ e Right Hand Coupling ANv -Star. F"Pleat= intemet alMalleable Iron Fittings Class 150 (Standard) Submittal Sheet etzANVIL t IC 14> APPROVED '7"' For Listing/Approval 4V 4. details contact your i AnvilStarru Representative. C ..FIGURE:1121 RIGHT.HAND COUPLING Size w Nughi Klock goly. NPS/DN 1111=1111 Ibr/ttg *Ar 1.i 0 06 0.06 A the _ 0� 0.09 + I :f OI3013 1 _. h I 'd 0.21 3/r i1 029 ; .. 0 31 1 1616 0 48 019 I A I'shs _ 0 71 0.76 TIT 2;A I I 2 I2'h 1 S I6 -----217: r'-----1-"Ti iti 7.4 ?.S — 3 3 t 33 31 4 31 As Si MATERIAL SPECIFICATIONS- . Anvil Class 150 (standard Weight)Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME 816.3 and Unions conform to ASME 816.39. Materials" issued by the Underwriters' laboratories, Inc. Anvil standard weight bonded pattern fittings in this catalog, All ELBOWS d TEES Ya-do DNI and LARGER ARE 100%GAS TESTED ATA sizes 1/8 NPS to 6 NPS (6 to 150 DN) inclusive, are included MINIMUM OF!O0 PSI.16.9 bort NOTE:See the Technical Dalt radion for pressuerlemperature ratings Sea AnvilStar Web site for the most current Listings and opproeols PROJECT INFORMATION: ' Project; APPROVAL STAMP: Date: Phone: Architect/Engineer: Contractor Address: Notes 1: -- Notes 2: Anvil Cast&Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule. • REv 03 03.06-0034 go to www.anvilslar.com 0t contact your local AnvilStar representativenAIWlIe; FIG. 1124 Cap AWILS Malleable fro F�•FwaKs.Memon An r near +rn•:�c.�y ='r� �4 n Fittings Class 150 (Standard) Submittal Sheet CjI • APF'ROVEO . FIGURE 1124 CAP • APPROVED ca FOr Listing/Approval details contact your Sire Weight AnvilStarna Representative block gala. NPS/DN 16s./kg lbs,/kg •h 003 004 •Y' 0.06 0.06 •is 0.09 0.1 11 0 12 0.11 0.22 01 1 0.38 0.38 '/s i 0 58 0.61 I'h 073 075 2 11 1.2 1th 18 18 2.6 2.8 3'h 32 32 4 45 46 6.4 6.9 6 i0 10 1 •Vs,1/4 d s/e 16,E&10 DNI are Mode in SIeml MATERIAL SPECIFICATIONS • Anvil Class 150 (standard Weight) Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME B16.3 and Unions conform to ASME B16.39 Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight banded pattern fittings in this catalog, At1EL0Ow5&TEES 3'e'(10DNI and LARGER ARE 100%GAS TESTED ATA sizes l/E NPS to 6 NPS (6 to 150 DN) inclusive, are included MINIMUM OF 100 PSI.(6.9 burl NOTE.See ilia Technical Dal°section for pressure.kmperoa.,rotingt See AnvilSlor Web silo for the most current lislings and approvals • PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect/Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast&Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe scltedute. U. 03 03 060035 go to www.anvilstat.com or contact your local AnvtiSlar representative 4 FIG,' 1105R• Reducing Tee - .....,. .. --� y ""LStaroaua,Division etAnvB,tnt.mnGan,i� V /IL Malleable Iron Fittings Class 150 (Standard) Submittal Sheet EFM �� J Z,{ + II— Y I 1APPROVED "1 i }- for Listing/Approval {I details contact your +_ AnvilStarTM Representative. -- -.- . •• FIG..1105R REDUCING TEE . Site z -� - ' 1 �- Wdg_ht — _ __ Y HP'DHT11P 'ON in mm in. mm i in mm /b� ndt�' 9atr. Site I x Wei,hl lb . 11PS,, ©- • 0.11 D Id 4�ON • WI In n "tea _tie. ' u, ,,+ ��L� Ib °i, t; n /, 013 014 — 0.45 0.46 A I % 14 0.36 - Ai 4 0.1905 " h + .1, 019 01 - Ins t.ti I n, 0.46 0.48 14 S 'As v11 /is 0.11 0S7 t, '^` i h l A 0.43 0 41- I .11 i.s ? 11 1 It ?' ) '1 In, IA I., 051 051 i 4 D19 + 0.19 A I ' Ins lb 0.38 04 ti /8 NM 0 21 011 4 Ins 1.4 1111111M0.16 /' n I,9 , I 4 }1 IAn, IA, Ih 046 - Ot9 03 031 I , i ti h I,t, ( ns ih 061 D66 I I A, 0.28 0 93 0.29 I--- I,i I , 1 I 1 I I 9 111111111 0.9 } l 0.27 0.19 '4 1114 I.1, I/ii 0.3 0 32 -4 14 .. 1.9 e 043 0.45 • I I I{} ( 11/ 055 T ,357 I 1 MATERIAL SPECIFICATIONS Anvil Class 150 (standard Weight) Malleable Iron Fittings in the "list of Inspected Fire Protection Equipment and conform to ASME B 16.3 and Unions conform to ASME 316.39. Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight bonded pattern fittings in this catalog, AU.ELBOWS 8 TEES-Ve f 10 DN) and LARGER ARE 100%GAS TESTED ATA sizes 1/8 NPS to 6 NPS (6 to 150 DN) inclusive, ore included MINIMUM OF 100 PSI.16.9boil NOTE.See the Technical Data section for pressure-temperature ratings See AnvifSior Web site for the most current Listings and approvals PROJECT INFORMATIO17: Project: APPROVAL STAMP: Date: Phone: Architect/Engineer: � Contractor: Address: Notes 1: -- -----..________ Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, pAaE I CT 3 env o0030& go to www.anvilstar cam or contact your local ArrrlStar rcpre�r•.nialice T+J�IV\/IL FIG, 1105R ReducingAN—TA-Star"• • "`Sta '" F ra Product%Dmxiond Anraf troy.,.......Malleable Iron Fittings Class 150 (Standard) Submittal Sheet ,firA r�': ' r1, Ggrii.f4,.... '.$irdl Y fq 1,t dur, FIG. 11058 REDUCING•TEE (CONT.) Size x 9 ! Srte X M,PoN HS NS O ®®® „ f � . , mONoff in, mm 1•„ �°,� �oh IA p6691h I } I At At j At t/ 1 14 0 55 , 0 55 1, f As 1 I'Ai I4 1.61 I1J INN r,h A h�IT;—�s I 05 062 7T 1.4 1.4 lh • 016 013 I C� 1h IAt 11111 I 1 lA 1/u 7 1r7 I A, ( `� 4 %, —1� — I r 059 I 061 ri- / I I A� I3 j S .4 IT 1 At 0.73 0 JS _ I I I n� I Ar I 4 L3 I r 1 I I 1'A r 1 t ry I'h i I __J_ 0.7q 081 I A� 11 ' 'b 14 1,'s 14 I OSS 1-OSS t�� tAr 14 1 'Ai I I I h' I ITys—� I;�{_ I/�� _ Ih f�� IT- --T �l t I I 0.6 1 0 63 I I 1 At I I no T 1''; 1 A 0— 0 74 I„ I I/e 1�A� I 1 I i /i I,h i 14 141 082 084 I., I I At I/i 1111 1 1A I At� 1 Ai 1rAt 092 091 1 14 I AI IA IIII f 14 t 1'.h` 1 A� I'ry ( 1_2___12 IIN IINI1 Ash— 1 AT f T 2 1 IA '16 1816 14 '4 I" 11111 1.4 ' I Ih r I t Al 1'At A I/t ' 087 094 (--__� 1-4- I A� I4 I5 H ' ,': h , 0 1Ip I�AI I Al ism 86 2 14i sinimi , 086 , I I I r,; 1 Aa I — _ I A 7 2'A 14 i I I •� 096 088 :—��— 7A ®® 1 Frli-H_ice- i;; 1/i I t 1 �-- _I 24 1 At 24 ne r I i4 I A I A 016 0.79 1 2/i I—2 1'%i I Firflpii • Iry 0.81 I I IA 14 IA T4 1'A I i 092 I% I 2 I r j ' I As 1 1 1 ( ' ( 4 T As II j I , 1 1V, am I At IA t____L_____ 1 I 2 1 A y 1 A 12 t I I '1 • 1 A IA-777 I O 86 0 89 I/; 14 1 Lb I !q 1 A ( "A 14 T- 1'AT 098 098 I 1'it I 1 At 24 !.8 I:, �� I/t VIII 1 A I 2 i At—T 2/��I© tAi 1A I 1 Ai 111 �_J_ 2 1'A 1A; ill1.7 14 �1� 1 I.T I I h i' T--,-- P �r^a S I S I l e 7 2 4 I 1'•t I/+— i 7 f 1 8 Anvil Cast &Malleable Iron Fittings +Fv 070306-0031 or the latest UIJUIG Llsted and FM Approved pressure ratings,versus pipe schedule, ,� PAOE 1 OF 3 F go to www,anvltstar.c0ni or contact your local AnvilStar representative ,tz)4nrvi - FIG. 1.10$R Reducing Tee `j(Z' .4M/1L Malleable Iron -- °.d� star Fittings Class 150 (Standard) Submittal E. �� r-j_; Sheet 1:111 APPROVED For Listing/Approval I -� '} details contact your t �� AnvilStarn Representative i_�. FIG. 11058 REDUCING TEE[coN)J Size ! X Y 2 Wei•hi -IPS ON 1 N ON—NPS OX in bloc ba v. She 1 mm in. mm ®�j /bs .h 1'hNPS DN PS ON NPS ON in,® blc4 3 4 �t ®� MI • it 2 I 1 r i ! ' fA 1 18 4 lin_ IMO 12 IIII ' 7-. • 1-; 31s 1 8 4 • 6.8 �` 1Y ih i2 1.4 I 1 I 4 ( 1h —JAF — 3Ar 34 --i�h 2 2 ---Tri-1- 75 —I S I f -I3 J-.4_--,, �i6 I �� , 16 � 2/1-171-2, —�-.2� I 24 3.5 �36 114 1 244 -TA` 2/e 34 35 i_. 2h 7-77,--.----p-, 1 A6 3.8 � 38 ! 1 1 —/TT21j4 2h 33 33 I 2h_ ?'As 14 1 Al 3.6 41 2'k T 1/41A+ 18 I 28 .. i 1 ' l'4 . 14 154 1 y 3 14 11/41 2•,14 21Ar 2 A , 33 i 35 j 1 i6 1/4 ! 1'h 35 r 36 1 1 24 IMO 36 3 3 2 Ar, S 8 6 • r 2 1 2 24 1 1/4 1T 4t 43 I 3 3/r J 24 31A 6I 165 1r--}i 1 17_� 13h 1,-2711 1-471— 14 8 '-1/7-7-7-7—"---ii I 1'1/6 . 3 I 58 59 3 I In 161-1-5-777—T-2 j I 1 ' 2 ' 14 I+ 422 1f�� 44 3 IL 1A; 244I 2/4 41 C1 I. )1 S3 2 troth--F 24 S8 58 24 1 Ac 73 611 61 Anvil Cast&Malleable Iron Fittings For the latest UUULC Listed and FM Approved pre5SUt8 ratings, versuspipe schedule, RFV 03 03.06-0032 PAGE 3 Of 3 go to www.anvilstar.corn or contact your local AnvilStar representative .FIG.-.7101 R_ Reducing Elbow 4 ,0! ! ta!' Malleable Iron Fittings Class 150 (Standard) PSubm 0®© �z_ APPHOVED r' For Listing/A - 11 PProval � I �.•' � Ig^^ details contact your "] _' I 1 AnvilStarnJ Representative. --' • FIGURE 11018 REDUCING:ELBOW. Si" I X • i Weigh; i _ block oc Si" I x MPS/12N___. NPS/ON ...___Wimp Wino _ 4 q � 0� I i*�'9 NPS/DN -j NP!/OM ih/� --1 Sew_. 0.1 � 11/2 !10.83V 0.85 �, ik; A 012 1 0.83 0.85 013 tidy t I 111111111111111111 r---771-4---W-1-11;17-1. -- t;---- -—— r r_r I I h s f ---�. 0 Id O.IS I k 1 Ar Mill 1A j 6 I t O.IT9 1 02 ! I !.1 12 •* .46 "s 0 21 I 01: 1-1-77---It 1 1 3 1.3 t,1 1.: 2 1111.1111111h I q 0.16 0.18 2 —J— >,s (" — 1 1,1-71-11-7V-1—. I —Mil 1 h 1.8 S Min i--h .3 I 11:? I 12'418 t 1 I " 1 0.39 i0.4 _ 1 h 114 23 1S 4 1'A4 11� 21h • MN 0 41 i 0.42 2 I �, 1111011111 2'A6 1 I 14 li} 0.4E :': 0.44 J 1 2 21/2 � �® t 1 ' I�1: oet 0.64 ' --_,_— j 3 3 4 3 19 I "' IAc —h_-i}/1 0.13 r 1 I 1146 I . 0.86 09 MATERIAL.SPECIFICATIONS Anvil Class 1.50 (standard Weight) Malleable Iron Fittings in the conform to ASME B16.3 and Unions conform to ASME B 16.39. Materials""List issued by the of Inspected FUndeire rwri ears' Laboratories, Inc. Anvil standard weight banded pattern fittings in this catalog, sizes IYe NPS to 6 NPS (6 to 150 DN) inclusive, are included Mslimu OF I OPSJ 9boriio )andIARGERARE 100%GASTEST®ATA M4NWWM Of 100 P51.IQ 9 bar NOTE See the Technical Dora seaion for pressure•temperoture rating: See Aev,lScer Web:ite for tke most current train 9s and opprads. PROJECT INFORMATION: Project: APPROVAL STAMP: . Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: --- Notes 2: APei 03 03 nvil Cast&0640 Malleable Iron Fittings For the latest MARC Listed and FMApproved pressure ratings,versus pipe schedule. 0o to tvww.anvllstar.eom or contact vont,InceArvitStar•euresentauve >1T;3�M/IL, • Reducer S • "�' /a�Wl4 Malleable Iron Fittings Class 150 (Standard) r �r' dard) Submittal Sheet ®®Q • — — • FIGURE 7125 RE APPROVED Size REDUCER N wei .. ForLisdng/APPrOvdl block 018 --� I decailsconcac[yatr 6'PS/DR� ' � Sirs ld wee--y�l— _ AnvilStarem Representative. r' AIIII 0.07 lbs ------,------ Work 0.08 071 08 v� 16i,/k. 0.t t 0.13 Ina 114 l l 1 th MN 1391 0 0 9 ' IIN A 01) 4Ild 11' I 1 09 091 0.11 015 ,„—1 _ 5 52 0 9 0.93 '.h h I'h 0.tS —ITT— y 19 —r-5 I 1.1 al 016 018' © 5 5 ' 13 I 011 025 11111-r1 I . Ili ..., 6 2''4e 11 1/ s/r ” 14.e 01? 013 Ih 15 IS 6.5nal »�LL1 FA 0.15 0.26 1-7175— 1111 63IIIII 16 t6 Ell 4 44a 96 92 0.16 018 ' n 0 37 f it 21 6 — + +� 10 ,I 0 35 21 21// 3'A 1 I In 'PoA 0.3S 0.33 1 _TH i i;At h I 1 2 1 039 0.41 � _1__ I 1 _ I LS I 6 ^ j'---072- Od1 — I 3.1 I J1 40.6 0 63 1--1ra -- 32 3 11/i h ?the I 0.64 065 . 1 ? Iq 311ht 33 35 0.68 0 7 1 31 31 24 3.3 34 M Anvil Class 150(standard Weight)Malleable Iron Fittings SPECIFICATIONS in the "List of Inspected Fire Protection Equipment and conform to ASME 816.3 and Unions conform to ASME B16.39 Moteriols" issued by the Underwriters' Laboratories, Inc. Anvil standard weight banded pattern fittings in this catalog, All EtBOWS&TEES h•I10OM mid LARGERAftE I00TGAS TESTED niA sizes 1/e NPS to 6 NPS (6 to 150 DN) inclusive, are included naw.ulMOFl00PS1.169bo4 NOTE iS..the technical Dora section for pressure-temperature ratings. See AneilSrar Wet!site to clue _ most coneM lnutgi and W+wavnls. Project: __ -,..__..•. PROJECT iNFOR6MiION 7 -- •_ Aim _,.., ��APPROVAL STAPr1P:• ��-�.•••-..«. Date: Phone: Architect/Engineer. Contractor: ----- Address: Notes 1: __-- Notes 2: Anvil Cast&Malleable Iron Fittings 4EV 03 0&0033For the latest UWLC Listed ane FM Approves pressure ratings,versus pipe schedule. Z��►w�L: go to www.anvllstar.com or contact your local AnviIStar representative • FIG' .1705 Straight Tee —�� , 'eiz tical Malleable Iron Fittings / n 0. -Star, , gClass 150 (Standard) n~� Submittal Sheet ® CI . . . .. ... .. .. . . . .... . .. APPROVED E'-'l105'STRAIGHTTEt`-' :_ _ __ For Listing/Approval Sire details contact your AnvilStarn.Representative. NPS/OM AI Ai _—. T— 009 0.1 t 0.15 016 IIIIIM 1 s 036 0.31 1 1 A 0 56 0.58 • 0.9 • 0.92 td 13 — — 1,4 TN-, - — 1 T ie - ,_a_ 2.5 28 24 2'At 4.9 _Lr . (� 3 3Aa j T1 S r f 1.3 Li.„.. 11111111111m4 9 0' 111111111111111 S 11111111111111111111111111111111 6 20 51, 26 30 'P.O.A MATERIAL SPECIFICATIONS • Anvil Class 150 (standard Weight) Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME B 16.3 and Unions conform to ASME B 16.39. Anvil standard weight banded pattern fittings in this catalog, AL1Et8OWSl&NNES>issued OM by tond iARGER, Ilters00%GASaAT Aries, Inc. sizes l/s NPS to 6 NPS (6 to 150 DN) inclusive, are included "(1141mum OF loo 9S9 l6.9 bar/ TESTED NOTE:See ills Technical Dab section for pressure-temperature ratings. See Aav,IStat Web see lot dbe moss currant In ingt and approrols. PROJECT iNFORt1ATION: Project: APPROVAL STAMP: 111111 Date: Phone: Architect/Engineer: Contractor: Address: Notes 1: Notes 2: AnvilZEV Cast&Malleable Iron Fittings For the latest UL/ULC listed and FM 00Approve::pr„sauce!clings,versus pipe schedule. go to www.anvjlstar.com or contact your local AnviISlar representative tZ'),e, /IM • ,7-...-.!''-.. ' "i....:..'. - ' • • " ••.- . "-•. ' '---'•'•.,-'•......'-!:..'••••••••••Y•-.. '-.- •-:•ri".11.j-iAq"..4riskA$71. ,'. ,--.- .. ' • .' . •-. -'. •"- - -.' --•:.-.__ VGwTM JJ Grooved Couplings MODEL V-7705 STANDARD FLEXIBLE COUPLING The VGS Model V-7705 flexible coupling _,1'• applications of moderate or high pressure sserviic s. Woror ukin in a pressureg vauy of usuallyy dictated by the wall thickness and rating of the pipe beingused.The Model is ite L..-r couplings feature flexibility that can deol with misalignent, distortion, V•7705 ,> :' stress, vibration and noise and also resist seismic tremors. With the use of Model __ L on, thermal V-7705 couplings you can even design a curved layout. See Typical Applications 1 -Flexible Couplings on page 25. y Sizes available: 1-1/2"_ mm Working Pressure:Up to 500 psi/35 bar 0 r' C 0 us 111181 LISTED APPROVED - 1 I/2•-8" Nominal Plpe Mao.Working 9 I Max.End Axial O.D. Pressure Load Dimensions --- Size mm/In ressu 1 Displacement A- 0 40 19.1 )5 -_4 kN/Lbs mm/In 1 mm/in mm/ln Bolt SIn Weight 40 I6 mm/in S K . 6 3 72 mm/n 9t/!Ja 1.900 SOO i 1420108 46 18o 0 SS SO 60.3 3S 0.0625 28] 1.25 191 0.7 379 x 2-1/e 3 1.6 2.373 500 W 129 Ie MIOx S/ 0e 6S • ••. 2.5 730 J5 144 fe 3.11 _T 142 41! _ 3M 100SS 19 65 2.875 _500 _ 7240 0.06'15 i 99 I 142 48 MW x55 09 78761 75 157 _ 16 39 559 189 3/e a 2-t/e 20 ._ II 102 147 48 MW x 55 10 90 99.9 35 �_.-_ 1 _ I 1 214 16--� n6 _ 3 I 3 500 500 I 4910 i Iff 169 ~� 49 M12 x 75 0 0625 1 8 100 114.3 35 354 ----72----r-i4.57 6 7 12 1 x3 12 9 4 4 500 500 I :45 176 52 I1/3 x 75 19 125 Iq 3 I � �eSb--rte 0.IZ5 � S 71 � 776 2 05 31 I 32 172 —234516x 41 150 1651 1 450 10910 1 0.125 I_677 _921 52 MI6x90 26 Jt b6.4 3 2 f w6 i 2.05 5/9 x 7.112 S I 260 I 54 M16 x 90 .- _____ ___..L.. .—. _ )1 ISO lye' m 690 I " 6 ( 6.625 150 15500 3 2 200 I 268 62 Mie x 90 0125 I 7 2 200 I 2191 Jt I 1169 72 I60 __ 10 55 i 244 3/96 90 70 e II 9625 150 I 26260 0.125 1024 ISO 64 M16 x90 5e I 1 1379 252 5/9x]-1!2 Ile 8110 ova-isle with h010p rine 9alvanaed rin,shed(oouona0 Trusted above aII.rM II ter , o G • FIG.*1705 Straight Tee lioVO • =)/�M�II Malleable Iron Fittings Class `"°`°d""'DMVonctstear� 9 150 (Standard) Submittal Sheet ®®el FIGURE11135:STRAIGHT TEE. APPROVED *----'.•'': For Listing Approval Size details contact your AnvilstarTM Representative. HPT/OM AI Ar r � __ 0 09 0.1 4 t _ • ---- _ __ 0.15 016 _ --t.-.7.-. -:1-5----- t:j L h - 036 I 0 56 111.11611111111 IA 0.9 0.97 lammimmi 1.4 Id 1111111111111111111/111111 t--A 'rte'`" Ininallininall. 9 0. IIIIIIIIIIIIII 1 3 , I I 1111111111111111 5 1 4 4 19 11111.11111 5I.' 26 30 "P.O.A MATERIAL SPECIFICATIONS • Anvil Class 150 (standard Weight)Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME 816.3 and Unions conform to ASME 816.39. Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight bonded pattern fittings in this catalog, AUEtaowsaTEES 4fir110ONM ond!ARM ARE I00%GAS TESTED ATA sizes IA NPS to 6 NPS (6 to 150 DN) inclusive, are included I MIF loops+t6.9bo4 NOM See the technical Dob section for pressors"MmperoWn:wings. See ArrilStor Web wit for t he most current listings end approvals. PROJECT INFORMATION: Project: APPROVAL STAMP: Date: Phone: Architect/Engineer. Contractor: Address: — Notes 1: Notes 2: Anvil Cast&Malleable Iron Fittings For the latest ULUSC sl6d and FM REV 0640?v MARX' Approve prssure rrepres, native plea schedule. go to www.anvllslar.com or contact your local AnvllStar representative x= Awn, A _FIG..1101.. so° Elbow • z � ML Malleable Iron Fittings CI 4r'r 9 ass 150 ,bn""ma•l ' (Standard) Submittal Sheet C)4APSII APPROVED For�isun9�Approval FIGURE 1101 90 ELBOW derails contact your . AnvilStarr.Representative. 1 `? ;` trj Site A �`_WJehi 4s.- bled krsiox = air. " 4 0.06 0? III.t' 0.11 • 012 (�� h "'` � 017 tr---1--\__f Ih 0.26 0.27 L1-1 : l A ;_L - _ i s 0.38 0.43 0.63 0.65 `- 1 ' 0.94 0 9; 1'? I' J 13 13 2 1 -2 2.1 2 it 2 IAi 11116111min ii 5 34: ! 3n' ri 72 4 3i^7T-- 8.9 91 3 l TT 14 1S • • Anvil Class 150(standard Weight)Malleable tron MAERIAL SPECIFICATIONS . ffns E B 16.39 in the "List of Inspected Fire Protection Equipment and conform to ASME B 16.3 and Unions conform to ASM Anvil standard weight banded pattern fittings in this catalog, AUEtsows&TEES h.iioou edu� �G Materiels" issued by the Underwriters' Laboratories, Inc. An IpO:$GAS TESTED AiA sizes lie NPS to 6 NPS (6 to 150 DN) inclusive, are included "mo OF 100Psl.(6.961 NOTE See the Technical Data serine for weave•lefnperolure ratings. See Am tSror W ol _ '� Web Jib 6rrhe'roil:r;rr nl ttu _ u7$.end4. ...J PROJECT INFORMATION: Project: Date: APPROVAL Sump: Architect/Engineer: Phone: Contractor: Address: Notes 1: _�_` N Notes 2: Anvil Cast&Malleable Iron Fittings For the latest UWL(;Listed and FMApproved iE V.07 0.'l.O600t3 g0 to WWW.anVllsta►.eom or contact your local Anv lStarr representative tative pipe schedule. FIG.-1105 Straight Tee • Zr�/�M/IL; Malleable Iron Fit �' °.`Stare Fittings Class 150 (Standard) Submittal Sheet g .. ® .- .._.. : .. `FIGURE,'1'1.05'STRA161i f . : ' -%'-v,:'''."--,•-:' ,-0..•---'-i-, APPRnVEO •• � - For Listing/Approval Size A Weight 1.11111101111111111 details contact your black Anvil$tarTM Representative. NPS/DN in/mm vs n I 0 09 lir./i9 —_ - -- — ---� A` -- O.IS 016 y:: .Jt. A 036 0.37 — .. ` ',Ai 056 t O.SA I/2 11/40.9 0.92 I/r _ 11 --- -- 17:�i — — — ----17----1 .s Id 2h 11 • 7.S 78 t— t'• 2 n 4j 4.9_r 1 A — 3 S t: T i j-- 1.3_ I I A 31 3A1 4 9 0• 9.4• 31r;, i II I? S t efi - 19 20 6 5;t 26 30 •P.O.A MATERIAL SPECIFICATIONS Anvil Class 150 (standard Weight) Malleable Iron Fittings in the "List of Inspected Fire Protection Equipment and conform to ASME B16.3 and Unions conform to ASME 616.39. Materials" issued by the Underwriters' Laboratories, Inc. Anvil standard weight bonded pattern fittings in this catalog, All Et8OWS8TEES 3-{10DN) and LARGER ARE I00%GAS TESTED ATA sizes Ye NPS to 6 NPS (6 to 150 DN) inclusive, are included MINIMUM OF 100 P51 ;6.9 hart NOTE:See the Technical Dela section for preesure-temporoNre rulings, See An.iistar Web pee for IN mast current lrltingland approvds. PROJECT INFORMATION: - Project: • APPROVAL STAMP: Date: Phone: Architect/Engineer: 1 Contractor: Address: Nates 1: - I Notes 2: Anvil Cast & Malleable Iron Fittings Fir the IdtOSt ! L 2FV 0303064070 �LU l i Slid and•c• r� app;0•;l :Oi@$Sl1(Z!a(if,S,versus Dina Scheduie, • go to www.anvitslar.cam or contact your local AnviISlar representative 11Y)AM/I Page 1 of 5 Forr LNo. F_012706 Rev 14.2 RICI:l. FREEDOM® RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK468 is a small. thermosensitive, glass- bulb residential sprinkler available in several different finishes and temperature ratings has been _ meet varying design requirements. The Electroless Nickel PTFE (ENT) , ,� .1 irt investigated for installationndicdincorrosiveApproval Chart.The orifice design, with is UaLK-Factor ofr4 9 1�� sion resistant as indicated in the for the hydraulically designed � (70.6 metrict), allows efficient use of available water supplies fire-protection system.The glass bulb operating element and special deflector characteris- - tics meet the challenges of residential sprinkler standards. LISTINGS AND APPROVALS ` � 2. -.--�-• � -`' c tl� us UL Listed (C-UL-US-EU): Category VKKW " E°- VdS Approved NYC Approved: MEA 89-92-E, Volume 35royal Chart UL Classified to: NSF/ANSI Standard 61, Drinking WatereSystem s that must be nentsed.MH48034). Refer to the App and Design Criteria for C UL US Listing t, 3. TECHNICAL DATA 3.,, COPY Specifications: Available since 2006. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metrict) tMetdc K-factor measurement shown is in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) Material Standards: Viking Technical Data may be found on Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000, Phosphor Bronze UNS-C51000, or Brass The Viking NCor konggrn's Websiit at UNS-C26000 Bulb: Glass, nominal 3 mm diameter e may include a more recent Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with edition The Web site this Technical Data Page. Polytetrafluoroethylene (PTFE)Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screw: Brass UNS-C36000 For ENT coated sprinklers: Belleville spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 13637 Order Sprinkler VK468 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number Finish Suffix: Brass =A, Chrome= F, White Polyester= M-/W, Black Polyester= M-/B, and ENT=JN Temperature Suffix: 155°F (68 °C) = B, 175 'F (79 °C) = D For example, sprinkler VK468 with a Brass finish and a 155°F (68 'C) temperature rating = Part No. 13637AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the`Sprinkler Accessories" section of the Viking data book) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B(available since 2000) B. Wrench for recessed sprinklers: Part No. 13577W/B•(available since 2006) G. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool" Part No. 15915(available since 2010.) 'A%'ratchet is required(not available from Viking). "Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: (Added VdS Approval) Form No. F_012706 Rev 14.2 Page 2 of 5 VIKING* FREEDOM"' RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) • The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. . TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature= Ordinary 155 °F (68 °C) 100°F (38 °C) Red Intermediate 175 'F (79 °C) 150 °F(65 °C) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings': ENT Footnotes 'The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT coated sprinklers,the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. /rench Flats miaow_ Protective 1 // Protective ; . ami i Sprinkl.er Sprinkler Cap Shield 1�^ 1®896 CO Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_012706 Rev 14.2Page 3 of 5 ti NIKING® FREEDOM' RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart Viking VK468, 4.9 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 130 or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Overall Length Part Number' Inches mm U.S. metric' Working Pressure Inches mm 13637 VK468 1/2 15 4.9 70.6 175 psi(12 bar) 2-1/4 58 Ordinary Temp Intermediate Temp g Approvals' Minimum Listin s and A rovals Max.Coverage Rating (155°F/68 °C) Rating (175°F/79 °C) Deflector Area Flow4 Pressure' Flow' Pressure' to Installation Spacing Ft.X Ft. Type C-UL- Ft. (m X m) GPM PSI GPM PSI Ceiling US- VdS NYCE NSF° (m) (L/min) (bar) (L/min) (bar) EU' 12 X 12 13 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) Standard sur- face-mounted 14 X 14 13 7.0 13 7.0 escutcheons,the (4.3 X 4.3) (49.2) (0.48) (49.2) (0.48) Microfast®Model F-1 Adjustable See See See See 16 X 16 13 7.0 13 7.0 1-1/8 to Escutcheon,or Foot- Foot- Foot- Foot- 8 (4.9 X 4.9) (49.2) (0.48) (49.2) (0.48) 2 inch recessed with notes notes note note (2.4) the Micromatic® 7 and 7 and 7 7. 18 X 18 17 12.0 17 12.0 Model E-1, 10. 10. (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) E-2,or E-3 Recessed 20 X 20 20 16.7 20 16.7 Escutcheon (6.1 X 6.1) (75.7) (1.15) (75.7) (1.15) Footnotes ' Part number shown is the base part number. For complete part number,refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 'For areas of coverage smaller than shown, use the 'Flow"and"Pressure"for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum"Flow"and"Pressure"used. s Listed by Underwriter's Laboratories, Inc.for use in the U.S.,Canada. and European Union. Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol. 35. 'Approved Finishes are: Brass, Chrome,White Polyester,and Black Polyester' UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components(MH48034). 'Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. "Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. • Form No. F_012706 Rev 14.2Page 4 of 5 NIKING0 FREEDOM') RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1 ------- 111 -)? Ali 7_-----_,--=7-1ii +- tireiliNirly, IIFyi i iil; ..1n;i�:.i . .; i it 1VO� WINO t i Sprinkler Wrench ` i -•___---.... 13577W/B*w must be .....— used for Installing Step 1: Carefully slide recessed Sprinkler ' the wrench sideways —_ around the deflector i � and protective shield. 111111 , (NoteStep 2: Carefully press the orientation of the wrench upward and the shield in the wrench.) turn slightly to ensure wwA 1/2' ratchet is required engagement with the (not available from Viking). sprinkler wrench flats. Figure 2: Wrench 13577W/B for Recessed Sprinkler Installed with a Microfast Model F-1 1/2' 111 mmpm! Adjustable Escutcheon ._..,__.__ lit (15 mm) —\\ -- _ — + �;_-- I __M- ---, NPT j j, r.ti 1 I im Itlifillf 1-3/4' .-.111.--- --- -4-11.7""1 1111110 (44.5 mm) /jJln titin(38.1 mm) = 'lIP l I 1111 I1-1/2' (38.1 mm) l2' (50.8 mm) lxi- I' Minimum 1 1.1. ..,.. Maximum ` l Installed with a I • 1 1-1/8' I [...1p.-1/8: ��� ���---111 standard 1/8' (3.1 mm) 1T1 (28.7 mm) surface-mounted escutcheon Sprinkler VK468 Figure 3: Sprinkler VK468 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon ,Form No. F_012706 Rev 14.2 Page 5 of 5 NIK1ING R' FREEDOM RESIDENTIAL TECHNICAL DATA PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Ceiling Opening Size: 2-5/16' (58.7 rim) minimum 2-1/2' (63.5 mm) maximum 1"3.1 1-3/4' I �N 1-1/8' (28.6 rim) 2, opip 1-1/8' (28.6 rim)Minimum <44.5 rim) \./ Minimum (50.8 rim) . Maximum Maximum Installed with a Microrhatic Installed with a threaded Micromatic Model E-1 Recessed Escutcheon Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK468 Dimensions with the Model E-1 and E-2 Recessed Escutcheons DESIGN CRITERIA (Also refer to the Approval Chart) UL Listing Requirements(C-UL-US-EU): When using Viking Residential Pendent Sprinkler VK468 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPAI3R applications for each listed area of coverage.Q • Calculated based on a minimum discharge of 0-1 gpm/sq. ft.over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers:8 ft.(2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, VdS, and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. (Added VdS Approval) �{ = 4 t "ii • ) tai* ' 1 `i '.� -T �"n.''�:' t NU = C ® d > ia+' wwWAIDCO.com _T— :AHEAD OF .T•HE ;FLOW.'- • ••• 06%21105 . - Class 125 Bronze Check Valves oe:,nc,r,°at..- Horizontal Swing • Regrinding Type • Y-Pattern • Res.stant Renewable Seat and Disc 125 PSI/8.6 Bar Saturated Steam to 353° F/178°C t� "1' : • 200 PS1/13.8 Bar Non-Shock Cold Working Pressure 3 .... ,.}.i' .... . .... • ........: CONFORMS TO MSS SP-80 MATERIAL LIST 1-413 PART SPECIFICATION Threaded 1 Bonnet Bronze ASTM B 62 2 Body Bronze ASTM 8 62 3 Hinge Pin Bronze ASTM B 140 Alloy 031400 or r l� B 134 Alloy C23000 — (z`` - 4 Disc Hanger Bronze ASTM 8 62 or • '• -: \,` 304 Stainless Steel'/a'thru Es" sizes (' •' t 5 Hanger Nut _ Bronze ASTM B 16 G- t.Y' 6 Disc Holder Bronze ASTM B 62 `D' '.i •.� 111 7 Seat Disc Water Oil or Gas iBuna-N;•W •y \`.` 44 1 Steam;PTFE)01) Bronze ASTM B 62:B) ---1=-. --- __ Viton 1V1 • --- --— ... 8 Seat Disc NutBronze ASTM_B 16 or B 62 r--- - — — 9 Hinge Pin Plug Bronze ASTM B 140 Alloy C32000 rot vow 7-4148 10 Seat Disc Washer ASTM B 98 Alloy C65500 f.�. N' or ASTM B 103 not shown •Sizes':".1"•1'.".and 11/2only • c). 47"16- \ 11, DIMENSIONS—WEIGHTS—QUANTITIESci) A - Dimensions �A1, ►'1 Size A B Master 41 4•' '�� Ii' In. mm. In. mm. In. mm. Lbs. Kg. Ctn.Qty. '1l El V.. 6 213 54 163 41 050 0 23 50 rw+�M.r.� o r.�.r. rhbT 'e 10 _213 54 163 41 047 022 50 `��. 'n 15 2.44 62169 43 055 0 25 50 T-413-Y Y.~20 2.94 75 1818 48 090 8 41 50 NPT x NPT 1 25 356 90 2.31 59 146 066 30 1'/. 32 419 105 269 68 2.17 099 20 1 1/2 40 450 114 294 75 295 1.34 10 2 50 5 25 133 394 100 4 79 217 IC 2' ' 65 800 203 506 129 1148 5 21 5 3' 80 9.25 235 6 25 :59 17 53 796 4 NIBCO check vales ma)be installed in both horizontal and OrderingT-413 normallyfurnished with Bronze Disc(T-413-Bl vertical lines witn upward flow or in any intermediate position They will operate satisfactorily in a declining plane Ino more Available with PTFE Steam Disc IT-413-Y)or CWP Disc than 15') (T-413-W)or 300'F 57 PSI steam Viton Disc(T.413-V) '-Class 150(433)furnished for these sizes Warning-Do Not Use For Reciprocating Air Compressor Ser.ice Si,: • ? - .._ :,t slot_ -JJ"."E''.:-',:_.-__: -1.6:-:,6-1-4:' :_32 : 3::-. __ . , INDOOR/OUTDOOR butterball ® BUTTERFLY VALVES VALVES LESS SUPERVISORY TAMPER SWITCH ASSEMBLY -C- 11' L ,. p s. I - - :S - - - C - BBVSC100 BBVSC100 3 piece with Uni-body with BB-SC100 (Threaded Ends) Grooved Ends Grooved Ends Sizes 1", 1-1/4", 1-1/2 ', 2",2-1/2" Size 2" Size 2-1/2" VALVES WITH SUPERVISORY TAMPER SWITCH ASSEMBLY • - FLOW MOld s : ^_ -- _, • J - LC - -o - - -., -- - ' —' THREADED ENDS NYC INDICATOR BB-SCS02 (Available on both smdched BBVSCS02 BBVSCS02 and non-switched moose's.) 3 piece with Uni-body with ALL DIMENSIONS-INCHES Grooved Ends Grooved Ends Size 2" Size 2-1/2" Threaded Grooved LSIZEI 1' _' 1-114" ' 1-1/2" • 2' 1 SIZE 2" _ 2-112" i A , 2-11 1 2-5'8 1 2-7/81_3-1:4 . A ,_ ._ 4-1.8 B 3.15:164 2 j 41,2 � 5 9 5 5-13;32 C 1.9/16 1-15116 2.3/16:2.3+4 ' C 1 2-3/4 3.3.16 0 1-23:32 2-7/64 2-3/8 3.1116 1 0 I 3-1/16 3-1/2 J 4-15/16 5-1/8 5-19/321 6-118 i E I 5/8 15116 I _K _ 66 .73 .73 1 .79 ( F 15116 . 518 r L .83 90 .99 1.41 (._G : 6 4-t'2 s41.4o 1.05 , 1.38 ( 1.61 2.07 H 12-3/8 ' 2-719,_- MATERIAL LIST, M-BO 96 i 1.28 1.50 I 1.94 I J 16-v8 6-1/4 I r_ 'N-40. 2 25 2 : 2 5 .4 2.25_ ,_ K _ .79. 118 I N0. PART • MATERIAL SPECIFICATION vv i ,-1.8 ,.-�-1 a 't-13321-ti:16.; L t.41 • i 29 1 Indicator S itered Iron F000SP M-40 2 07 ?47 • . V-10 A:,E DIMENSIONS USING SCHED:;LE .'--- -.- ------ 2 Ho;;_in Bronze ASTM 584 PCPE M-Ac 1.94 z 32 --_ _. _._.._. . M-80 ARE D.MENSIO`IS USING SCHEDULE ,N-40 2.25 - 1.0 , : 3 Body _ Bronze ASTM 584 0 PIPE .. NW .....-. - 1=3;4 4 Hand•+e Brass N-40.s FLOW RESISTANCE EXPRESSED+:ti5 Disc Stainless-tees Type 304 EQUIVALENT LENGTH OF SCHEDULE 40 PIPE ~6 Disc Seal EPDM Elastoma_ ` W IS THE WRENCH MAKE-UP LENGTH 7 Switch Housing Die Cast Alum n1m September 15 20C9 • EASYPAC RESIDENTIAL NIKINGR TECHNICAL DATA RISER MANIFOLD ASSEMBLIES -2'iDN2o- DN,5C • The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 • Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking EasyPac Residential Riser Manifold Assemblies are available in sizes 1". 1-114'. 1-'-2 . and 2 for NFPA 133 and NFFA13R residential fire sprinkler systems. The configuration eliminates the need to drain the system before+rs:a brig the relief valve. wtiie built in test port allows hydrostatic testing without draining the system The EasyPac Residential Assernb.es include pressure gauges Potter flow switches.3-way gauge control valve and 1"drain valve(or 1-114"for 2'Manifold) The EasyPac assemblies are made:•.:I' steel bodies and are available in threaded or grooved connections. 2. LISTINGS AND APPROVALS Pressure Gauges: UL Listed. FM Approved Waterflow Alarm Switch: UL Listed - Category USQT.cUL Listed FM Approved-Wa!erfow Detectors. Vane Type CSM Listen Ball Valve: UL Listed. FM Approved AGF TestanDrain Model 1000: UL Listed-Category VEHZ FM Approved-Sprinkler System Alarm Testers AGF TestanDrain Model 1011 with Pressure Relief Valve:UL Listed-Category VEHZ,FM Approvec-Spririker System Alarm.Testers 3. TECHNICAL DATA : V:k+ng Technical Data may be found on Specifications and Material Standards: I The Viking Corporation's Web site at Available since 2007. http-I/www vikinggroupinc corn • Pressure Rating 250 PSI (17.2 bar)maximum water working pressure. Tne Web site may include amore recent • Fabricated steel pipe. edition of this Technical Data Page • Available in male NPT threaded inlet and outlet connections using Schedule 40 steel p•pe • Available in grooved inlet and outlet connections using Schedule 10 steel pipe • Available with male NPT threaded inlet x grooved outlet using Schedule 40 steel pipe • Riser bodies coated with black Ecoat. • Flow Switch:Two single-pole double-throw switches with Form C contacts rated at 15 Amps 125'25'V AC 2.5 Amp 0-30 Each switch can be wired for open or closed circuit operation. See Figure 1. Ordering Information: (Also refer to the current Viking price list.) There are three different options available for the Residentia'line Basic Residential EasyPac Assemblies with Ball Valve Drain(See Figure 2) Residential EasyPac Assemblies with TESTanDRAIN Va've(See Figure 3) Residential EasyPac Assemblies with TESTanDRAIN and Pressure Relief Valve (PRV)(See Figure 4) See Table 1 for Part Numbers 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Note:The EasyPac Residential Riser Manifold Assembly can be installed horizontally with flow switch on top.or vertically with flow upward Viking EasyPac Riser Assemblies use Potter VSR flow switches The literature that accompanies Pie VSR states that the switch shout not be installed within 6-of a change of direction of pipe or within 24- of a valve.This is merely a recommendation to reduce the pos- sibility of the switch not operating while minimal waterf ow is occurring This is a recommendation or.ty not a requirement 5. TESTANDRAIN VALVE OPERATING INSTRUCTIONS 1. To Test:Turn valve handle counterclockwise from"Off to"Test-.The handle will stop automatically After test is completed rat.:•'' handle to"Off 2. To Drain: Turn handle counterclockwise from "Off to 'Test". The handle will stop automatically Depress "Push' ocaor• and Lr' handle to "Drain". When system is empty, return handle clockwise to"Off'position 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection Testing and Maintenance requirements 7. AVAILABILITY The Viking EasyPac Riser Assemblies are available through a network of domestic and ir.terratior.a distributors See Tr. ! .cg C poration web site for the closest distributor or contact The Vking Corporation. 8. GUARANTEE For details of warranty. refer to Viking-s current list pace schedule or contact Viking direct:, Form No F_102407 Replaces cage 31a-'da:e:. J.:ly 3`. 2•:'::9 Remo.ea +:,!e regarc .-, •1.-.r.... .-....i.-f,f,.,r•-,- . -r,r..nr.., .'- • runt f:rri. Cut:Cut:t,-• I 3`h Septerncer 18 2'1:. iR EASYPAC RESIDENTIAL NIKING TECHNICAL DATA RISER MANIFOLD ASSEMBLIES - 2 ,,DN25- DN5U The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com i Table 1 -Commercial EasyPac Assemblies TESTanORAIN Option: r Ir,ci_ces a L .orifice with size spe_i iec Inlet/Outlet Viking Part from 3 8 K2 F,to 25K ESFR' deper•ding Pipe Size Connections Option Pipe Size Number Cr the-;ma!est spank er.r'Ma ed rn the Bat Valve 15226 syster' Fust aid s.,ffix tc the cart'-_awe• Thread/Thread TESTanDRAIN Schedule 40 15227 for tie oes.red cn+te s ze ITESTanDRAIN and PRV 15228 Orifice Suffix: 1 2 8; ' A=318' ' Bail Valve 15243 'c i B=7'16.(K42i Groove!Groove TESTanDRAIN Schedule 10 15244 • C=1/2"11(5 6) TESTanDRAIN and PRV 15245 0= 17/32";K 8 0, Ball Valve 14840 i Thread/Thread TESTanDRAIN Schedule 40 15229 TESTanDRAIN with PRV Option: TESTanDRAIN and PRV 15230 lnc6,des:es:orifice and pressure ret of Ball Valve 14841 valve. Tre!sr.!crit ce m.st be si•ec•f e. - t-1'4• Groove• Groo,e TESTanDRAIN Schedule 10 15231 cased or.ire sma.est spnr.de nava ec n TESTanDRAIN and PRV 15232 • the system for 318• (K2 8)lc K25 ESFR' • Tne pressure relief valve is not factory Be Valve 14905 asselue c to t Tes!anDrain Must ayid Thread/Groo+e TESTanORAIN Schedule 40 15233 suffix to the p•3':n_mber for:1 e desired TESTanDRAIN and PRV 15234 orifice size anc pressure setting of tre Ball Valve 14842 pressure relief valve Thread/Thread TESTanDRAIN Schedule 40 15235 Orifice Suffix: TESTanDRAIN and PRV 15236 A= 3 8 (K 2 8i Ball Valve 14843 ! C- 7 16 1K 4 1t L= 1/2'1K 5e t 1-v2• Groove!Groove TESTanDRAIN Schedule 10 15237 D= 17132 .K 8 C. TESTanORAIN and PRV 15238 PRV Suffix Ball Valve 14849 175 Thread/Groore TESTanDRAIN Schedule 40 15239 115 TESTanDRAIN and PRV 1524C : 195 Ball Valve 14844 • 205 Thread/Thread TESTanDRA1N Schedule 40 15241 : 225 250 TESTanDRAIN and PRV 14901 NOTE:It is important to note that the Ball Valve 14845 pressure rating of the rel'ef�a'v, rid cats_ 2 Groove!Groove TESTanDRAIN Schedule 10 15242 ' a:oG�rdt,ny rd'ye of presswe _,Gal TESTanDRAIN and PRV 14900 penins and rlc;ntg of the:a:e Stan!a': Bali Valve 14846 rel et va,es are regaired to OPEN ^a range. Thread/Groo:e TESTanORAIN Schedule 40 15246 cI pressure between 90%aria 1Cf-. of tre.r 1ESTanORAIN and PRV 15247 rating Th:varves are required t:.CLOSE a: -- a press •e acove 80%of that rtlai'g Table 2-Pipe Diameters 1" 1-114" 1-112" 2" Pipe OD 1 315"(33 4 mm) 1 660'(42 mm) 1 900 (48 r 2 375 •60 mm) Schedule 10 Pipe ID 1 097•'(27 9 mint 145"(36 6 mm) 1 69•(42 7 r': 2 16' 54 A mm' Schedule 40 Pipe ID 1 049"(26 6 mm) 1 38•'(35 1 mm) 1 61' (40$ ry,_ c 07 ;52 5 snm) i Figure 1 -Flow Switch with Two Single Pole, Double Throw Micro , Switches September 18.2009 - • R EASYPAC RESIDENTIAL TECHNICAL DATA RISER MANIFOLD ASSEMBLIES • -2 (C/N25-DN5G The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com !-- -F- ^H -- —. y-© • I �._ aoez -- I I� a) ,, ' W I I c F CIi . j- .._r-1 /' 1 , • iI A - •c,: - D ( - r{'> - -1 is I �, . -f _ t 1 ill , - I - ;r.E7�1 T- B --_ 1 E- -- + — — 1 : 1 t -B I 1" (DN25)1 1-1/4" -2" (DN32-DN50) I Figure 2 -Basic Residential EasyPac — Size A B C D E F G H I ' 16-132" 14.1516" 1" 6-3 16' 5 3.4 3-1(2' 8 1"(DN25)1 VSR-S F;o%Switch- 1"Hose (409) (379) (25) r 1:7) 1'46; 189) 1203 1 1/4"(DN32) VSR-S ROA S:ntc�' 1' NPT 16-1.2' 15 1-1;2' 6-3 32 6-1' 32- 4.316 6.9+ 6• (419• 1361; (38) 1155) !'611 (107) ;218' 1 112"(DN40) VSR-S How Switch, t"NPT 16-1:2• 15 1-1''2 6.7 32• 6-15 '0 4-5,16 9.'1.16 (419) (381) (38) 11.6; 1'6-li i1.10; 1243 . 2"(DN50) VSR Flow Swatch' 1-1;4'NPT 14.1/2' 13 1'2 9.7 Iii 5-51 64' 5' 9.23 64 (369) (330) (-12)2 1164; 1`48) (127) 1239: 'The body of the 1'manifold is comprised of four V nipples and three tee's. Dimension E is negative because the ball valve extends below the end of the manifold oody • • 'Mounted with included nipple(As shown above) 'Mounted with included U bolt(Not Shov.n; -'— --- ---.------- ---.—._------------- Note: Dimensions may vary by± 1/4" (6.3 mm) • • * \ GUARDIAN Ph.800 if ku FIRE EnuIPMI,FL MENT,INC. DETAIL AND SUBMITTAL SHEET / MIA327 6584•Fax 800.827.3869 5000 Series - Hose Valves Project/Location: Date: Architect/Engineer. —_ Qty: Contractor: l7Appropriate Selection Female x Male Angle Valves-Used as tire hose outlet connections.Female NPT inlet x Male hose thread outlet,300 PSI,cast brass,UL listed/FM approved A Model No. I Size I A I B(Open)I C I D I Swing Radius ❑ solo 1Wx1W 4- 7W 2W 2' I 2W 8 c.:= 0 ❑ 5015 2Wx2W 5W 11' I 3W 2W I 3W I j t1-1 Optional Finish:0-B Polished Brass 0-C Rough Chrome Plated 0-D Polished Chrome Plated L_r_ .iY:.-i Threads:❑NST ❑Other - C Female x Female Angle Valves-Used with hose rack assemblies Female NPT inlet and outlet,300 PSI 5ofo/5o15 cast brass,UL listed/FM approved. _ A 1 Model No. I Size I A I B(Open)I C I D I Swing Radius ❑ 5020 1W x 1W 4- 1 _7W 2W 2' 2W 6 _ �L 0 ❑ 5025 2'%'x 2W I 5W + 11' I 3W 2W 3W I f Optional Finish:❑-B Polished Brass 0-C Rough Chrome Plated ❑-D Polished Chrome PlatedL. 4 i Female x Male Pressure Restricting Angle Valves-Used as fire hose outlet connections Field-adjustable C restricting mechanism reduces water pressure under flowing conditions(175 PSI max inlet) When full flow 5020/5025 is required,restriction can be over-ridden by trained personnel.Female NPT x Male hose thread outlet, 175 PSI,cast brass,UL listed/FM Approved. ---A Model No. Size I A 1B(Open) C I D Swing Radius I - , �j ❑ 5030 1W x 1W 4' 9 -_. D ❑ 5035 2W x 2W 5V' 11'x4' ! •I Optional Finish:0-B Polished Brass 0-C Rough Chrome Plated 0-D Polished Chrome Plated 1. � Threads:❑NST ❑Other ' r C 5030/5035 Female x Female Pressure Restricting Valves-Used with hose rack assemblies. Field-adjustable re- stricting mechanism reduces water pressure under flowing conditions(175 PSI max.inlet). When full flow —A•-1 is required,restriction can be over-ridden by trained personnel.Female NPT inlet and outlet,175 PSI,cast brass,UL listed/FM Approved. ,i—' Model No. I Size I . A 1B (Open)I C I D I Swing Radius s o ❑ 5040 1Wx1Yx 4' i ' ` .i ❑ 5045 2W x 2W 5W i -r;,73,--1 Optional Finish:0-B Polished Brass - C ❑-C Rough Chrome Plated ❑-D Polished Chrome Plated 5040/5045 Caps with Chains-Caps with Chains-Used to protect hose Reducer-Used to change outlet size Rigid pin thread outlets on valves and hydrants lug',female x male threads Cast brass caps(pin lugs)'or red plastic caps(rocker lugs) Model No. ! Size Threads: t., Model No. I Size I Type. Threads: 0 3315 i 2% x 1W ❑NST ❑NST n ❑ 5515 1W Brass y Optional Finish: ❑Other ❑ 5515P 1W Plastic ❑Other T�JL ❑-B Polished Brass l ❑ 5525 2W Brass ;,J 0-C Rough Chrome Plated ❑-D Polished Chrome Plated ❑ 5525P 2W Plastic O tional: p ❑-RL Rocker lugs Optional Finish:El-B Polished Brass 0-C Rough Chrome Plated 0-D Polished Chrome Plated *Optional:0-RL Rocker lugs = GUARDIAN kitiff II i Ph.80FIREEQUIPMENTM ,INC. DETAIL AND SUBMITTAL SHEET IAMI,FL 0.327.6584•Fax 800.827.3869 6300 Series - Fire Dept. Inlet Connections - Bodies Project/Location: Date: Architect/Engineer: Qty: Contractor: gAppropriate Selection Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow(minimum),per f--'--- ----_-� 2'/:"inlet. = -- IA 1 � . ii /� Two and three-way-inlet connections feature clappered brass bodies(straight t- i• • —���' I or angle pattern),with female hose thread swivel inlets and female outlets.Cast __B brass construction,standard. 6314 Two and Three-Way Connections • B Model No. I Outlet I Size I Clappers I A B _-- ❑6314' Back 4"x 2'/a"x 2'/i 1 I 4:,.--_,\ ' 5'/i 8'/: ` I ❑6315' Angle 4'x 2'/i x 2W 1 8'/; 8'/: A rk�%! ❑6324 Back 4'x 2'!i x 2W 2 7'/: 10'/i I 4 �4�% ❑6325 Angle 4'x 2'/i x 2'/:' 2 8'/: 10'/i t ❑6326 Back 6'x 2'l:"x 2'!i 2 7'/: 10'/i 6315 ❑6327 Angle 6'x 21/2'x 2W 2 �_10' 107:' ——� ❑6336 Back 6"x 2'/:'x 2'h"x 2'li 3 10Y{ 13'/: -/��\l ❑6337 Angle : 6'x 2'G"x 2'!2"x 2'/,' 3 11'!2 I 14'/i A /� \\ Body Lettering . 1 ❑AUTO SPKR ❑STANDPIPE f ❑Blank(unlettered) 6324/6328 'Auto Spkr lettering only Optional Finish:❑-B Polished Brass Threads: r ' — 1 ❑-C Rough Chrome Plated I �� 0NST i ❑-0 Polished Chrome Plated 0 Other I L.-- i 6325/6327 Plugs with Chains and Break Caps-Used to keep fire dept.inlet connections free of debris and f . -• protect female threads. �✓ I Plugs with Chains Break Caps p 6 r Model No. Size Type'. it��d l ��II YP ,,- Model No.I Size I -Type f ❑ 6404 i 2'/:" Brass - --�-- III ❑6406 2'/i Aluminum __ —---1 Optional Finish: ! 0 6407 2'/i Plastic _ a ❑-B Polished 6336 ❑-C Rough Chrome Plated Threads: Adjustable Plugs ❑-D Polished Chrome Plated ❑NST 1---B Model No.i Sae I Type ❑Omer ❑6408 21/2' Aluminum I 71 9 6409 2'/:' Plastic A r`+ I 7 p--6-4r _., , Contact factory for current listings and approvals 6337 1 August 04, 2013 Sprinkler 43o • NIKING„,„ QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Horizontal Sidewall Sprinkler VK360 is a thermosensitive glass bulb spray sprinkler available in several different finishes and temperature rat- ings to meet varying design requirements. The special Polyester and PTFE coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. ) t 2. LISTINGS AND APPROVALS t' ut „ cULus Listed: Category VNIV Refer to the Approval Chart on page 43r and Design Criteria on page 43s for cULus Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2009. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread Size: 3/4" (20 mm) NPT Nominal K-Factor: 8.0 U.S. (115.2 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F(-55 °C) Overall Length: 2-5/8" (66 mm) Viking Technical Data may be found on Covered by the following US Patent Nos: 7,854,269 and 7,712,218 The Viking Corporation's Web site at Material Standards: http:llwww.vikinggroupinc.com. Sprinkler Frame: Brass UNS-C84400 The Web site may include a more recent Deflector: Brass UNS-C23000 or Phosphor Bronze UNS-C51000 edition of this Technical Data Page. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screws: 18-8 Stainless Steel Yoke: Phosphor Bronze UNS-C51000 Ejector Spring: 17-7 Stainless Steel For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the ap- propriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome= F, White Polyester= M-/W, Black Polyester= M-/B, and Black PTFE = N Temperature Suffix (°F/°C): 135°/57°=A, 155°/68° = B, 175°/79° =D, 200°/93° = E For example, sprinkler VK360 with a Brass finish and a 155 °F/68 °C temperature rating = Part No. 15591AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B(available since 2000). B. Wrench for recessed sprinklers with protective shields: Part No. 13655W/B"(available since 2003) **A%'ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) Form No. F_092508 Replaces page 43o-t, dated February 26, 2010. (Added Patent Nos) Sprinkler 43p August 14, 2013 NIKING® QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the yoke, pip cap, and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Quick Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Wrench Sprinkler Flat Shield ,Elly X11 O .. _ 10996 0 Figure 1: Standard Sprinkler Wrench 10896WIB August 14, 2013 Sprinkler 43q N11(1Not QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and Black PTFE Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE Footnotes 'The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart.These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. Sprinkler Wrench Part No. 13655W/Bx must be used with Coated and/or Recessed Sprinkler VK360. (Recessed Sprinkler' VK360 is shown.) Fit the wrench over the sprinkler and protective shield as shown. (Note the orientation of ' Sprinkler the shield in the wrench,) Protective I Shield �///: 1 `\•\\\\ 1 1 711: I I iill ll�(1111!II I._ —i- -`4--_ I.—.U_ .—f-_i"_--_—_—.___iII4�_.__—.,IIllIiIGG�I �_i/ / 11Ipp al�l��� 1 1 I II: : � Refer to data page QR1-3 for xNote: A 1/2' ratchet complete installation instructions and Figure 3 is required (not for correct final deflector orientation. available from Viking). Figure 2: Installation of Coated and/or Recessed Sprinkler VK360 Sprinkler 43r August 14, 2013 NIKING® QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking ive, Hastings MI 49058 Telephone: 269-945-9501 TechnicalCorporation, Services: 877-384-5464' Fax: 269al Park -818-1680 Email: vikin cor tecchsvcs@ 9 p.com Approval Chart i--Temperature KEYQuick Response Horizontal Sidewall Sprinkler VK360 For Light or OrdinaryHazard Occupancies. A7�f Escutcheon tit applicable) Deflector must be located 4"to 12"(102 mm to 305 mm)below the ceiling. Base Part Nominal , SIN Maximum Thread Size Overall Length Listings and Approvals' Number' Pressure K-Factor g (Refer also to Design Criteria on pg 43s.) NPT BSP U.S. I metric' Inches I mm cULus4 NYC 1 FM LPCB (E 0 15591 VK360 175 psi 3/4" 20 mm 8.0 115.2 2-5/8 66 Al X See Footnote 5. f l I o Approved Temperature Ratings Approved Escutcheons Approved Finishes X - Installed with standard surface-mounted escutcheons or A-135°F(57°C),155°F(68°C), 175°F 1 - Brass, Chrome, White Polyester6, Black the Viking Microfase Model F-1 Adjustable Escutcheon6, (79°C),and 200°F(93°C) Polyester6, and Black PTFE6 or recessed with the Viking Micromatice Model E-1 or E-2 Recessed Escutcheon, or the Model G-1 Recessed Escutcheon Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Other approvals may be in process. 'Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. Meets New York City requirements,effective July 1, 2008. c cULus Listed as corrosion-resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. Ceiling—/ Note top and bottom of the deflector. The top surface is marked 'TOP'. The sprinkler MUST be oriented as shown. 4' (100 mm) Keep leading edge of minimum the deflector oriented to 12' FLOW parallel to the ceiling, 1F104 Measure from top of (304.8 mm) TOP maximum I [ Top of deflector to ceiling. deflector i �mo.... /Era\ r'... 175T 79•C t • illit ‘a' Bottom of •� � deflector Keep the sprinkler Frame arms oriented parallel to the ceiling. Figure 3: Correct Deflector Orientation August 14, 2013 Sprinkler 43s N11(ING® QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Industrial Park Viking Corporation, 7 N Drive, Hastings MI 49058 269-945-9501 Technical Seryces: 87845464 Fax: 29818- 80 Email: tehsvcs vikin cor .co m DESIGN CRITERIA (Also refer to the Approval Chart on page 43r.) cULus Listing Reauirements: Quick Response Horizontal Sprinkler VK360 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • Locate the deflector 4"to 12"(102 mm to 305 mm)below the ceiling. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. • Minimum spacing allowed is 6 ft. (1.8 m). • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. DEFLECTOR POSITION:Install sprinkler VK360 with the leading edge of the deflector and the sprinkler frame arms oriented parallel to the ceiling(see Figure 3). THE TOP SURFACE OF THE DEFLECTOR IS MARKED"TOP".The sprinkler must be oriented as shown in Figure 3. IMPORTANT: Always refer to Bulletin Form No. F_091599 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes,ordinances, and standards, whenever applicable. Wall Opening Size! 2-5/16' (58.7 mm) minimum 2-1/2' (63.5 mm) maximum 2-1/2' 1-15/16' 2-5/8' (63.5 mm) (49 mm) (66 mm) I Minimum I 1t Ill ,�;�✓I II ��,•_._�� (54 II�■i I-dI rtrt) . 3/4' pl� (20 rim) Sprinkler VK360 NPT 111 2-1/2' (63.5 mm) Maximum Installed with a standard 1/8' (3.1 mm) Installed with a MicroFast surFace-mountedescutcheon. Model F-1 Adjustable Escutcheon. Figure 4: Sidewall Sprinkler VK360 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sprinkler 43t August 14, 2013 NII<ING R QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLER VK360 (K8.0) The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Wall Opening Size: 2-5/16' (58.7 mm) minimum 2-1/2' (63.5 mm) maximum 1-3/4' 1-1/2' <45 mm) (38 mm) I I Minimum Minimum I� 111 ail' • D2-1/8' IIIiI�I ( � .iiiii•Imili,� 1,1111r==''� _It \ (54 mm) IIIIIII IIIla -—it -i it 2-1/8' Till ., il,,,I,. 7 <54 mm) i •' —'w: -,I1 II�Ul-I■' �� pi I 2-1/2' II <63.5 mm) 2-1/8' Maximum (54 mm) Maximum Installed with a Model E-2 Thread-on Recessed Escutcheon. Installed with a Micromatic Model E-1 Recessed Escutcheon. Figure 5: Sidewall Sprinkler VK360 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Wall Opening: 1/8' 2-5/8' (66 mm) Minimum (3.2 Mn) 3-3/4' (95 rim) Maximum -I I-J Adjustable Adjustable ,I Outer Cup \ _I Adapter � -1- - i, Ring ir 111 mil, ,, ,,, x,. ali„� I I.. _.� 2-5/8' 4' ,,, ,I', �,. '�111111.4.. ill-tel (66 mm) t; ./% N. �Ii�ftill (102 mm) , . Depth1-1/16: •,� ' (27 rim) 1-1/16" i 1 I- Maximum Recess: (27 mm) 1/2' (12.7 mm) Figure 6: Sprinkler VK360 Dimensions with the Model G-1 Escutcheon Form No. F_092508 Replaces page 43o-t, dated February 26, 2010. (Added Patent Nos) ii Page 1 of 4 ® MICROFAST® QUICK TECHNICAL DATA • RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Microfasta'Quick Response Upright Sprinkler VK350 is a small, then- mosensitive, glass-bulb spray sprinkler available in several different finishes, y � n temperature ratings, and K-Factors to meet design requirements. The special t Polyester, Polytetrafluoroethylene (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In ad- s u • dition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant.FM Global has no approval classification for PTFE and Polyester coatings as corrosion x" resistant.) ,; , 2. LISTINGS AND APPROVALS ut o: cULus Listed: Category VNIV <M FM Approved: Class Series 2000 [VdS) VdS Approved: Certificates G414017 and G414018 �. LPCB Approved «cep E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0786-CPD-40278 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA , E ��� Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)' I Maximum Working Pressure: 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP, 3/4" NPT, 20 mm BSP Nominal K-Factor: 8.0 U.S. (115.2 metric") Glass-bulb fluid temperature rated to-65 °F(-55°C) Viking Technical Data may be found on Overall Length: 2-5/16" (59 mm) The Viking Corporation's Web site at 'cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi(0.5 bar). http://www.vikinclude ainc.com. The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). The Web situ may include more recent Material Standards: edition of this Technical Data Page. Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfasta Quick Response Upright Sprinkler VK350 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome= F, White Polyester= M-/W, Black Polyester= M-/B, and Black PTFE = N, ENT=JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK350 with a 1/2"thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 18259AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: Form No. F_033014 Rev 14.2 (Added 06665B, 14817, and 06764B) Page 2 of 4 • \\EKING® MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast®Quick Response Upright Sprinkler VK350 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. -'' TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES • •Sprinkler Temperature Sprinkler Nominal •Classification Temperature Rating' Maximum Ordinary Ambient . 0 Ceiling Temperature2 Bulb Color 135°F(57°C) 100°F(38°C) Ordinary 155°F(68°C) Orange Intermediate 100°F(38°C) Red 175°F(79°C) 150°F(65°C) Intermediate 200°F(93°C) G High 150°F(65°C) Greene 286°F(141 °C) 225°F(107°C) Sprinkler Finishes: Brass, Chrome,White Polyester, Black Polyester,Black PTFE,and ENT Blue Corroslon-Resistant Coatings':White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135°F(57°C) 'The sprinkler temperature rating is stamped on the deflector. Footnotes 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester,ENT,and PTFE coatings. For ENT coated automatic sprinklers,the waterway is coated. Protective Sprinkler Cap Wrench Flat a .lt finy,. .,. ••t 10896 . Figure 1: Form No. F_033014 Rev 14.2 Standard Sprinkler Wrench 10896W/B i Page 3 of 4 • NIK1NGMICROFAST®QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com . Approval Chart 1 (UL) — f 'Temperature KEY • Microfasta Quick Response ti—s, Finish . Upright Sprinkler VK350 • A . E1�'�nhea�tiapp'�ba)� Maximum 175 PSI(12 bar)WWP Base Part Thread Size Nominal K-Factor Overall Length SIN (Refer also to Design Criteria.) Listings and Approvals' Number' NPT BSP U.S. metric' Inches mm cULus4 VdS LPCB (E 18257 VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B2 18278 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B2 Al Al B1' Al Al 182599 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, 62 1' Al 8 -- 61° NOTICE-Product Below-Limited Availability(Contact Local Viking Office)- 06665B VK350 3/4" — 8.0 115.2 2-5/16 59 Al, 82 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, 62 Al Al 81' 067646' VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al B2 Al Al Al Al 1 -- Ale Approved Temperature Ratings A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F(93 °C), and Approved Finishes 286°F(141°C) 1 -Brass, Chrome, White Polyester", and Black Polyester" B- 155°F(68°C), 175°F(79°C), 200°F(93°C), and 286°F(141°C) 2 ENTS Footnotes 'Base part number is shown.For complete part number,refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa.divide the metric K-factor shown by 10-0. 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 'Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5cULUs Listed as corrosion resistant. °Other colors are available on request with the same Listings and Approvals as the standard colors. 'CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. °CE Certified,Standard EN 12259-1,EC-certificate of conformity 0786-CPD-40278. 9The 1/2"NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. DESIGN CRITERIA- Ut., ' • (Also refer to Approval Chart 1) cULus Listing Reauirements; The Microfasta Quick Response Upright Sprinkler VK350 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 Rev 14.2 I a Page 4 of 4 NIKING® MICROFAST® QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK350 (K8.0) The Telephone: 269-945-9501 Technical Sery Services: 877-384-5464 1 Fax: 69al Park -818-ive, 116801 Email: tecchsvcs@vikin cor .corn 9 p Approvafthart 2 (FM) Tempa a oro - KEY Microfast°Quick Response —Finish Upright Sprinkler VK350-• AlX4-Escutcheoh(ii appi!cable)l . ;;,.;„:>E.,. :, .. „:,,�. = Maximum 175 PS1(12 bar)WWP ` �t, �.f Base Part Thread Size Nominal K-Factor Overall Length •`'provals3 aM .,: Number' SIN FM Approvals NPT BSP U.S. metric2 Inches mm (Refer also to Design Criteria below.) 18257 VK350 3/4" -- 8.0 115.2 2-5/16 59 Al, B2 18278 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, B2 182595 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 NOT/CE=Product Below-L . /mitedAvailabi/ity(Contact Local Viking Office) Al, 62 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 4 14817 VK350 -- Al, B2 20 mm 8.0 115.2 2-5/16 59 Al 82 0676485 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F(57°C), 155°F(68 °C), 175°F(79 °C), 200°F(93 °C), and 286°F(141°C) 1 Brass, Chrome, White Polyester', and Black B-155°F(68°C), 175 °F(79°C), 200°F(93°C), and 286°F(141°C) Polyester' 2-ENTB Footnotes 'Base part number is shown.For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing.Check with the manufacturer for any additional approvals. 'Other colors are available on request with the same Approvals as the standard colors. °The 1/2'NPT Large Orifice Sprinkler is listed and approved for retrofit only when installed in accordance with NFPA 13. °FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Reauirements; The Microfast°Quick Response Upright Sprinkler VK350 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide.For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033014 Rev 14.2 (Added 06665B, 14817, and 06764B) Page 1 of 6 NimNG® MICROFAST'' QUICK TECHNICAL DATAT - '` RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION ;� ;mss The Viking Microfast' Quick Response Pendent Sprinkler VK302 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester, Polytetrafluoroethelyne (PTFE), and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval j Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for PTFE and Polyester coatings as corro- sion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV fH, FM Approved: Class Series 2000 vas VdS Approved: Certificates G414009 and G414010 LPCB Approved c E CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Chart 1 and Design Criteria cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Viking Technical Data may be found on The Viking Corporation's Web site at Specifications: http://www.vikinggroupinc.com. Minimum Operating Pressure: 7 psi (0.5 bar) The Web site may include a more recent Rated to 175 psi (12 bar)water working pressure edition of this Technical Data Page. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric") Glass-bulb fluid temperature rated to-65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) 'cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass =A, Chrome = F, White Polyester= M-/W, Black Polyester= M-/B, Black PTFE = N, and ENT =JN Temperature Suffix: 135 "F (68 "C) =A, 155 'F (68 'C) = B, 175 °F (79 "C) = D, 200 °F (93 °C) = E, 286 'F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 `C) temperature rating = Part No. 12979AB Form No. F_033314 Rev 15.2 • Page 2 of 6 MICROFAST') QUICK NIKING TECHNICAL DATA- - RESPONSE PENDENT - SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B.Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B" (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool"' Part No. 15915 (available since 2010) "A%z"ratchet is required(not available from Viking). •"Allows use from the floor by attaching a length of 1"diameter CPVC tubing to the tool.Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A(available since 1971) B. Twelve-head capacity: Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast'Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Wrench Flat Clip Protective Sprinkler Cap • • Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_033314 Rev 15.2 Page 3 of 6 1 R MICROFASP QUICK TECHN1CAL.DATA RESPONSE PENDENT , 4 , ...., SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES -_. _. Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 'C) 100 'F (38 °C) Orange Ordinary 155 °F (68 'C) 100 'F (38 °C) Red Intermediate 175 'F (79 'C) 150 'F (65 °C) Yellow ) Intermediate 200 °F (93 °C 150 °F (65 °C) Green High 286 °F (141 'C) 225 'F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. i Refer to specific installation standards. 'The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester,PTFE,and ENT coatings. For ENT coated automatic sprinklers,the waterway is coated I • 4.64ANN\ Sprinkler wrench 13655W/B** `'• � � " for recessed pendent 4 sprinklersk( . . .I "A 1/2" ratchet is required 1 � -.� �' r - (not available from Viking) ; -"."" Carefully slide the wrench sideways around �'A - the protective cap, ensuring engagement witl- -4-'— the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 Rev 15.2 Page 4 of 6 • NIKINGINGi 8) MICROFAST' QUICK i . TECHNICAL DATA. .- RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com � Approval Chart 1 (UL) Temperature KEY The Viking Microfast'Quick Response ,;i----Fmish Pendent Sprinkler VK302 A1X4 Esalchecn(.l3 Gticabte) i Maximum 175 PSI(12 Bar)WWP BaseNominal Overall Listings and Approvals' Sprinkler Thread Size K-Factor Length (Refer also to Design Criteria.) Part SIN Style Number' NPT BSP U.S. metric= Inches mm cULus' VdS LPCB (E' Qi' 12979 VK302 Pendent 112- 15 mm 5.6 80.6 2-1/4 58 A1Z,SlY,02,C2X Al A1Z,BlY DIZ,C1Y – D3Z NOTICE-Product Below-Limited Availability(Contact Local Vikkw Office)) 066628 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AIZ,B1Y,02.C2X – – – • 18021 VK302 Pendent 112- 15 mm 5.6 80.6 2-1/4 58 AIX,B1Y Al AIX,B1Y D1X,C1Ya D1X,Cl Y' – Approved Temperature Ratings Approved Finishes Approved Escutcheons A-135°F(57°C), 155°F(68°C), 175°F 1 -Brass,Chrome,White X-Standard surface-mounted escutcheon or the (79°C),200°F(93°C),286°F(141 °C) Polyester'',Black Polyes- Viking Micromatic`Model E-1 Recessed Escutcheon B-135°F(57'C), 155°F(68°C), 175°F ter`' Y-Standard surface-mounted escutcheon or the (79°C),and 200'F(93°C) 2-ENT' Viking tvlicrofast'Model F-1 Adjustable Escutcheon,or recessed with the Viking Micro- C-155°F(68°C), 175'F(79'C),and 3-Chrome mate Model E-1,E-2,or E-3 Recessed Escutcheon 200'F(93°C) Z-Standard surface-mounted escutcheon or the D-155'F(68°C), 175"F(79°C).200°F Viking Microfast`Model F-1 Adjustable Escutcheon (93°C),286°F(141 °C) -"— Footnotes 'Base part number shown.For complete part number,refer to Viking's current price schedule. I Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Other approvals may be in process. Listed by Underwriters Laboratories Inc.for use in the U.S-and Canada. 'cULus Listed as corrosion-resistant. F Other colors are available on request with the same Listings and Approvals as the standard colors. 'CE Certified,Standard EN 12259-1,EC-certificate of conformity 0832-CPD-2001. 'CE Certified,Standard EN 12259-1,EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. ''MED Certified,Standard EN 12259-1,EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: ;The Viking Microfast'Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 Rev 15.2 Page 5 of 6 ,NIKING. .: MICROFASTP QUICK TECHNICAL DATA " RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) -.. Tempera:are KEY The Viking Microfast' Quick Response •+----'Fin;sh Al X 4 Esc:1c^.e.cn idapp:icable) Pendent Sprinkler VK302 Maximum 175 PSI(12 Bar)WWP _ Base Part I SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' Style NPT BSP U.S. metric' Inches mm (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y,D2X,C2 NOTICE-Product Below-Limited Availability(Contact Local.Viking Office) 4144SMOVAVORP. 066628 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,BIY,D2X,C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z,B1Y Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A- 135'F(57`C), 155'F(68°C), 175°F(79°C),200 'F Viking Micromatic-' Model E-1 Recessed (93°C), 286°F(141 °C) Approved Finishes Escutcheon B- 135°F (57 'C), 155 °F (68 'C), 175°F (79°C), and 1-Brass,Chrome,White Polyester', Y - Standard surface-mounted escutcheon or the 200°F(93°C) and Black Polyester' Viking Microfast"Model F-1 Adjustable Escutcheon, C - 155 'F(68 'C), 175 °F(79 °C), 200 °F (93 °C), 286 2-ENT' or recessed with the Viking Micromatic"Model E-1 'F(141 °C) or E-2 Recessed Escutcheon D- 155°F(68°C),175°F(79°C),200°F(93°C) Z - Standard surface-mounted escutcheon or the Viking Microfast'Model F-1 Adjustable Escutcheon Footnotes i'Base part number shown. For complete part number, refer to Viking's current price schedule. 12 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing.Other approvals may be in process. °Other colors are available on request with the same Approvals as the standard colors. 'FM approved as corrosion resistant. I DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) _ FM Approval Requirements: The Viking Microfast'Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage upright and pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to,but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances,and standards, whenever applicable. Form No. F_033314 Rev 15.2 'age 6 of 6 .N4 4 - :. MICROFAST� QUICK , TECHNICAL DATA RESPONSE PENDENT , . _ : : SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com =__ ,_„ t Ceiling Opening Size: 112" 2-5/16" (58.7 mm) minimum (15 mm) 1 2-1/2" (63.5 mm) maximum NPT 2-118" (54 mm) t ."---i-Z... i 1-1/2" 2-1/4" 1 t-1 ' I 1-3/4" 2" g (38 mm) (57 mm) } 4 (51 mm) Min. (44.5 rnm) Max. . li , - J -.L Ja NY.' K�- .. Jea.. - Installed with a standard Installed with a Microfast Note:At maximum,adapter is 1/8" surface-mounted Model F-1 Adjustable exposed 112"(12.7 mm)from escutcheonEscutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon . Ceiling Opening Size: 2-5-16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum • ro— 2-1/8" 2-1/8" (54 mm) • mm)� 14111—(54 1-1/8" 1-1/8" 1-3/4" l I (28.6 mm) 2"" (28.6 mm) (44.5 mm) Min. (51 mm) ,... - Min. Max. Max. t . -. .. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 Rev 15.2 Replaces Form No. F_033314 Rev 15.1 (Renlaced wrenr.h 16036W/R with 13Fti5W/R1