1740 MARITIME OAK DR - ENERGY SHEETi r OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RIVER2641 (Revised) Builder Name: Riverside Homes Street: 1740 Maritime Oak DrivePermit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach,FL,"30.093 Permit Number: Owner: Parker Residence Jurisdiction: 261100 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) New(From 1. New construction or existing Plans) 9. Wall Types(3019.6 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 2644.60 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=19.0 375.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1639.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=22.0 1560.00 ft2 2 2658 b.Knee Wall(Unvented) R=0.0 79.00 ft2 6 .Conditioned floor area above grade(ft) c.N/A R= ft Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(404.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 528.2 a. U-Factor: Dbl,U=0.35 404.67 ft2 SHGC: SHGC=0.22 ft2 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a.Central Unit 48.0 SEER:14.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 48.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.553 ft. 14.Hot water systems Area Weighted Average SHGC: 0.220 a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (2658.0 sqft.) Insulation Area EF:0.860 a.Slab-On-Grade Edge Insulation R=0.0 1560.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1098.00 ft2 None c. N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 65.52 PASS Glass/Floor Area: 0.152 Total Baseline Loads: 74.97 I hereby certify that the plans and specifications covered by Review of the plans and •'o�-itiE.sxAr '%;. this calculation are in compliance with the Florida Energy specifications covered by this °pti,,.-- t�?`;* • Opt; Code. calculation indicates compliance !.„, ;: * t, Douglas R. Digitally signed by Douglas R.Suckles iS,••`N 0 T DH:m=Douglas R.Suckles,c=US,o=A/ with the Florida Energy Code. • `iu,u . ,., (Masters HVAC,Inc Before construction is completed •- �'g' PREPARED BY: StIEIE�eS ,' e DATE: - - this building will be inspected for ; (9'•.. compliance with Section 553.908 I hereby certifythat this building, as designed, is in compliance Florida Statutes. ?. 14:%. -../.. ..�:A../ 9 + COD-;11:- ; with the Florida Energy Code. .. � . OWNER/AGENT: il.' � _� � BUILDING OFFICIAL: ill daDATE: ;;: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 11/30/2016 10:00 AM EnergyGauge®Ener Gau e®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: RIVER2641 (Revised) Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2658 Lot# 112 Owner: Parker Residence Total Stories: 2 Block/SubDivision: Atlantic Bch CC #of Units: 1 Worst Case: No PlatBook: Builder Name: Riverside Homes Rotate Angle: 0 Street: 1740 Maritime Oak Driv Permit Office: City of Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Blockl 2658 25482 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 1560 15600 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 1098 9882 No 3 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 166.9 ft 0 1560 ft' ____ 0.3 0.7 0 2 Floor Over Other Space 2nd Floor ____ __-- 1098 ft2 0 0.15 0.85 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1807 ft' 0 ft' Medium 0.6 No 0.4 No 22 30.3 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1560 ft2 N N 11/30/2016 10:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 NI FORM R405-2014 CEILING ✓ # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) 1st Floor 0 Blown 462 ft2 0.11 Wood 2 Under Attic(Unvented) 2nd Floor 0 Blown 1098 ft2 0.11 Wood 3 Knee Wall(Unvented) 2nd Floor 0 Blown 79 ft2 0.11 Wood WALLS Ad scentCavityWidth Height Sheathing Framing Solar Below 1 Space Ft in Area R-vatue-Ecaction ansn�Grade% VIt Ornt To Wall Type R-VabU Ft I[t- _ 1 N Exterior Frame-Wood 1st Floor 19 36 3 10 362.5 ft2 0.23 0.75 0 2 E Exterior Frame-Wood 1st Floor 19 47 10 470.0 ft2 0.23 0.75 0 _ 3 S Exterior Frame-Wood 1st Floor 19 31 10 310.0 ft2 0.23 0.75 0 4 W Exterior Frame-Wood 1st Floor 19 15 10 150.0 ft2 0.23 0.75 0 5 W Garage Frame-Wood 1st Floor 19 37 6 10 375.0 ft2 0.23 0.01 0 6 N Exterior Frame-Wood 2nd Floor 19 6 3 18.0 ft2 0.23 0.75 0 _ 7 W Exterior Frame-Wood 2nd Floor 19 6 3 9 56.3 ft2 0.23 0.75 0 8 N Exterior Frame-Wood 2nd Floor 19 12 3 5 6 67.4 ft2 0.23 0.75 0 9 W Exterior Frame-Wood 2nd Floor 19 10 9 9 96.8 ft2 0.23 0.75 0 _10 N Exterior Frame-Wood 2nd Floor 19 12 9 9 114.8 ft2 0.23 0.75 0 11 E Exterior Frame-Wood 2nd Floor 19 47 9 423.0 ft2 0.23 0.75 0 _12 S Exterior Frame-Wood 2nd Floor 19 34 9 306.0 ft2 0.23 0.75 0 _13 W Exterior Frame-Wood 2nd Floor 19 30 9 270.0 ft2 0.23 0.75 0 DOORS Storms U-Value Width Height Area V # Ornt Door Type Space Ft In Ft In 1 S Insulated 1st Floor None .46 3 8 24 ft2 2 W Insulated 1st Floor None .46 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.35 0.22 8.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 2 N 1 Vinyl Low-E Double Yes 0.35 0.22 16.5 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None - 3 E 2 Vinyl Low-E Double Yes 0.35 0.22 33.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 4 E 2 Vinyl Low-E Double Yes 0.35 0.22 29.3 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 5 E 2 Vinyl Low-E Double Yes 0.35 0.22 36.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None - 6 S 3 Vinyl Low-E Double Yes 0.35 0.22 85.3 ft2 13 ft 8 in 1 ft 0 in Drapes/blinds None - 7 S 3 Vinyl Low-E Double Yes 0.35 0.22 12.0 ft2 13 ft 8 in 1 ft 0 in Drapes/blinds None 8 W 4 Vinyl Low-E Double Yes 0.35 0.22 4.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 9 E 11 Vinyl Low-E Double Yes 0.35 0.22 75.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 10 E 11 Vinyl Low-E Double Yes 0.35 0.22 4.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 11 S 12 Vinyl Low-E Double Yes 0.35 0.22 30.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 12 S 12 Vinyl Low-E Double Yes 0.35 0.22 37.5 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 13 W 13 Vinyl Low-E Double Yes 0.35 0.22 30.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 14 W 13 Vinyl Low-E Double Yes 0.35 0.22 4.0 ft2 1 ft 8 in 1 ft 0 in Drapes/blinds None 11/30/2016 10:00 AM 9Y 9 Ener Gau e®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE ______V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 496 ft2 496 ft2 64 ft 10 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000426 2972.9 163.21 306.94 .4042 7 HEATING SYSTEM V # System Type Subtype _ _Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 48 kBtulhr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 14 48 kBtu/hr 1440 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF - Cap - Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.86 1 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM JFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Su pi ---Return--- Air CFM 25 CFM25 HVAC# P Y V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 528.2 ft Attic 132.05 Default Leakage 2nd Floor (Default) (Default) 1 1 11/30/2016 10:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling f ]]Jan [[ ]Feb [[ ]Mar ]Apr Ma X Jun X Jul X Au [X]Se ct Novv Dec Venting [X]Jan [X Feb [X]Mar [X Apr [ 1 May [ 1 Jun [ 1 Jul [ 'Aug l 'Sep 1)(19 Oct X�Nov Dec Venting [ ]]Jan [[ ]]]Feb [[X]Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) PM 66 66 66 66 66 68 68 68 68 68 68 68 M 68 68 68 68 68 68 68 68 68 68 66 66 11/30/2016 10:00 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. 1740 Maritime Oak Drive, Atlantic Beach, FL, New(From Plans)New construction or existing 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 2644.60 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=19.0 375.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 d.N/A R= ft2 4. Number of Bedrooms 4 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=22.0 1560.00 ft2 6. Conditioned floor area(ft2) 2658 b.Knee Wall(Unvented) R=0.0 79.00 ft2 c.N/A R= ft2 7. Windows** Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.35 404.67 ft2 a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 528.2 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 48.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 48.0 HSPF:8.20 Area Weighted Average Overhang Depth: 4.553 ft. Area Weighted Average SHGC: 0.220 8. Floor Types Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1560.00 ft2 a.Natural Gas EF:0.86 b.Floor Over Other Space R=0.0 1098.00 ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ...• 114,E ST "•••.,,. Construction through the above energy saving features which will be installed (or exceeded) �, :. ,;;. ..0 in this home before final inspection. Otherwise, a new EPL Display Card will be completed iv. ��'', s s `. .„.6 based on installed Code compliant features. ;'i.i' """'.:, _,`".''„ 0 Builder Signature: Date: l?./��,, � ` . Address of New Home: ti Lit) ca tkiosfie. City/FL Zip•: A. .�cn�tr fit^ Z • 'cp ���5 I� •2-72 3 . *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/30/2016 10:01 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods IADDRESS: 1740 Maritime Oak Drive Permit Number: I Atlantic Beach,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 0 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section • 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/30/2016 10:01 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls • capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/30/2016 10:01 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ▪ R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights • ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. 0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or • concrete deck roofs do not have sufficent space,R-10 is allowed. 11/30/2016 10:01 AM EnergyGaugem USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RIVER2641 (Revised) Builder Name: Riverside Homes Street: 1740 Maritime Oak Drive Permit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Parker Residence Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside % and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. i'fr Exposed earth in unvented crawl spaces shall be covered with a Class I IV vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. ✓ Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in j exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air / barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or / air sealed boxes shall be installed. 1/ HVAC register boots HVAC register boots that penetrate building thermal envelope shall be V sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have J gasketed doors 11/30/2016 10:01 AM 9Y 9 Ener Gau e®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 Job: RIVER2736 F " Manual S Compliance Report wrightsot Date: 11130!16 Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 Project Information For: Riverside Homes 12276 San Jose Boulevard, Suite #120, Jacksonville, FL 32223 Cooling Equipment Design Conditions Outdoor design DB: 93.0°F Sensible gain: 34003 Btuh Entering coil DB: 77.6°F Outdoor design WB:77.0°F Latent gain: 6925 Btuh Entering coil WB: 63.8°F Indoor design DB: 75.0°F Total gain: 40928 Btuh Indoor RH: 50% Estimated airflow: 1533 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0480000A+FB4CNP048L Actual airflow: 1533 cfm Sensible capacity: 33180 Btuh 98% of load Latent capacity: 10240 Btuh 148% of load Total capacity: 43420 Btuh 106% of load SHR: 76% Heating Equipment Design Conditions Outdoor design DB: 32.0°F Heat loss: 37458 Btuh Entering coil DB: 68.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0480000A+FB4CNP048L Actual airflow: 1533 cfm a balance: 28 °F Output capacity: 46000 Btuh 123% of load CapacityEconomic balance:-99 °F Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1533 cfm Output capacity: 10.6 kW 97% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2016-Nov-30 10:06:21 wrightsoft" Right-Suite®Universal 2017 17.0.08 RSU13256 Page 1 ACCN ...Homes\ATLANTIC BEACH CC\ABCC112(Parker-Rev).rup Calc=MJ8 Front Door faces: S Job: RIVER2736 Project Summary Date: 11!30!16 -F` - wrightsot Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax.904-722-8944 Pro'ect Information For: Riverside Homes 12276 San Jose Boulevard, Suite#120, Jacksonville, FL 32223 Notes: Lot 112,Atlantic Beach C. C. Parker Residence REVISED Desi• n Information Weather: Jacksonville, Intl Airport, FL, US Winter Design Conditions Summer Design Conditions 32 °F Outside db 93 °F Outside db Inside db 75 °F Inside db 70 °F 18 °F Design TD 38 °F Design TD Daily range M M Relative humidity 50 % 50 gr/lb Moisture difference Heating Summary Sensible Cooling Equipment Load Sizing Structure 26427 Btuh Structure 21027 Btuh 1 Ducts 11031 Btuh Ducts 12976 Btuh 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 37458 Btuh Use manufacturer's data 1.00y Rate/swing multiplier Infiltration Equipment sensible load 34003 Btuh Method Detailed Latent Cooling Equipment Load Sizing Shielding 3 (partial)1 Structure 3550 Btuh Stories Ducts 3375 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 2658 2658 Equipment latent load 6925 Btuh Volume (ft') 25251 25251 40928 Btuh Air changes/hour 0 0 Equipment total load Equiv.AVF(cfm) 0 0 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade 14 SEER PURON HP Trade 14 SEER PURON HP Model CH14NB0480000A Cond CH14NB0480000A AHRI ref 7835757 Coil FB4CNP048L AHRI ref 7835757 Efficiency 8.2 HSPF Efficiency 11.7 EER, 14 SEER Heating Sensible cooling 32200 Btuh Heating output 45500 Btuh @ 47°F Latent cooling 13800 Btuh46000 Btuh Temperature rise 27 °F Total cooling 000 cfm Actual air flow 1533 cfm Actual air flow 1 1533 cfm/Btuh Air flow factor 0.041 cfm/Btuh Air flow factor 0 inc H2O Static pressure 0 in H2O Static pressure Space thermostat Load sensible heat ratio 0.83 Capacity balance point= 28 °F Backup: Input= 11 kW, Output= 36182 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Nov-30 10:06:21 4.`-... 'Iii.Y WrightsOft` Right-Suite®Universal 2017 17.0.08 RSU13256 Page 1 ACCP ...Homes\ATLANTIC BEACH CC1ABCC112(Parker-Rev).rup Calc=MJ8 Front Door faces: S • 4• wrightsoft' Right-J®Worksheet Job: RIVER2736Date: 11/30/16 Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax:904-722-8944 Entire House Whole House 1 Room named wall325.9 ft 325.9 ft 2 Exposed9.5 9.5 ft heat/cool 3 R000mm height ft 2658.0 x 1.0 ft 4 Room dim2658.0 ft' 2658.0 ft' 5 Room areaa Load Area (ft') Load Ty number tion U-valuefOr Btuh//ft') orM ea perimeter (ft) (Btuh) or perimeter (ft) (Btuh) number (Btuh/ft F) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 VII 12E-Osw 0.068 n 2.58 1.46 563 538 1390 787 563 538 1390 787 L-G 3A-2ov 0.350 n 13.30 10.86 25 0 333 272 25 0 333 272 V,11 12E-Osw 0.068 e 2.58 1.46 893 716 1850 1047 893 716 1850 1047 G 3A-2ov 0.350 e 13.30 36.32 177 23 2354 6428 177 12 2354 6428 11 \J 12E-0sw 0.068 s 2.58 1.46 616 427 1103 624 616 427 1103 624 3A-2ov 0.350 s 13.30 20.86 165 330 2195 3442 165 165 2195 3442 D 11J0 0.600 s 22.80 18.36 24 24 547 441 24 24 547 441 IW 12E-Osw 0.068 w 2.58 1.46 573 535 1382 782 573 535 1382 782 (; L3A-2ov 0.350 w 13.30 36.32 38 5 505 1380 38 2 505 1380 6 0.097 3.69 1.73 375 354 1305 611 375 354 1305 611 1211 JO0sw 0.600 w 22.80 18.36 21 21 479 386 21 21 479 386 P 16B-Oad 0.408 - 15.50 22.07 79 79 1225 1744 79 79 1225 1744 C 16X19-0ad 0.408 n 2.15 1.59 462 462 994 735 4622 4622 9944 7355 F 20P-19w 0.050 - 0.00 0.00 0 0 0 0 F 22A-tph 1.358 n 51.60 0.00 1560 209 10765 0 1560 209 10765 0 6 c)AED excursion 0 0 Envelope loss/gain 26427 18677 26427 18677 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 5 1150 Appliances/other 1200 1200 Subtotal pines 6 to 13) 26427 21027 26427 21027 Less extemal load 0 0 0 0 0 0 Less transfer 0 0 0 0 14 Subtotal Redistribution 26427 21027 26427 21027 15 Duct loads 42% 62% 11031 12976 42% 62% 11031 12976 Total room load 37458 34003 37458 34003 ? Air required(cfm) 1533 1533 1533 1533 • Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-Nov-30 10:06:21 .fc- � wrightsOft' Right-Suite®Universal 2017 17.0.08 RSU13256 Page 1 ...Homes\ATLANTIC BEACH CC\ABCC112(Parker-Rev).rup Calc=MJ8 Front Door faces: S ' Building Analysis Job: RIVER2736Date: 11130116 -I - wrightsoft"' Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 Pro'ect Information For: Riverside Homes 12276 San Jose Boulevard, Suite #120, Jacksonville, FL 32223 Design Conditions Location: Indoor: Heating Cooling JacksIndoor temperature (°F) 70 75 Elevation: Intl Airport, FL, US Design TD (°F) 38 18 301 ft Relative humidity (%) 30 50 Latitude:oo31°N Moisture difference (gr/Ib) 11.5 50.0 Outdoor: Heating Cooling Dry bulb (°F) 32 93 Infiltration: Detailed Daily range (°F) - 18 ( M ) Method Wet bulb °F - 77 Shielding 3 (partial) Wind speed(mph) 15.0 7.5 Stories 1 IIOIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINCEMIIIIIIIIIIINIIIIIIIIIIIIIIIIIII Component Btuh/ft2 Btuh % of load Walls 3.1 8256 22.0 w;:10, Glazing 13.3 5387 14.4 °',` Doors 22.8 1026 2.7 Ceilings 2.2 994 2.7 Floors 6.9 10765 28.7 Infiltration 0 0 0 Ducts 11031 29.4 Glaring Piping 0 0 Humidification 0 0 Oo 0 0 Gangs VentilationFloss Adjustments 0 Total 37458 100.0 Coolin• Component Btuh/ft2 Btuh % of load IM Walls 2.1 5595 16.5 w Glazing 28.4 11522 33.9 Doors 18.4 826 2.4 Ceilings 1.6 735 2.2 Floors 0 Ii Infiltration 0 0 0 Ducts 12976 38.2 Ventilation 0 0 Internal gains 2350 6.9 Glazing 0 0 Adjustments 0 Total 34003 100.0 CalmsDoors Latent Cooling Load = 6925 Btuh Overall U-value = 0.168 Btuh/ft2-°F Data entries checked. ill 2016-Nov-30 10:06:22 41- wrightsofr Right-Suites Universal 2017 17.0.08 RSU13256 Page 1 �"-- S A0-11/4...Homes\ATLANTIC BEACH CC\ABCC112(Parker-Rev).rup Calc=MJ8 Front Door faces: . W Cr] r..1 ;C igen m' "i c /'1 R .0 A .n 8, Eaii 1Etg i 8 11110 ii g . cii,....0 2 ih itk Piiiiilil > ,.. IR 'i 4- - a 0 , s 11 Og o .0 ( sa � f; 11 a. 1141 w11, HI 0ocN[LgLe[ RgFZcn x z: . �}6 l.l.l J Q 5 Ul F ° � � • QRZtgO -II lK YO o. OLL ♦Y Qa'n S 'gyp �r AIIININIFAL,i � H �gi K u..i , n' jjs. �_1I L LlQWgo 4411111 , Emillo, A.Tiii, iiptilli s. I Lu co i m� Cr,t, . 1sk r�NT 1, ..• . 4r-iiiii NNMI Ii41 ),Lit,- .411111-11.'-EZEidiliii10111 .11 100.1•11 c in y lig ^T_ R - ..,._. �.m. J Jig, i $ ag� M 4,.. %---_. W. i e.00 r• L t t I Y I,IS 4 " r ii _ n 41 . 1. t ill 16 .rt16 44 .... 6 as YYY S .. 14 t° 11 ._ i- I� :.I x yC ( t : t�IVrr)1,8 x a> VHAv9 < 8 • t e UW . 6^8 3 U as • t I {` Y itraniM1--- 4 ll °'»' �C,'- '"1 y 1 1 0. �_� r.�.� 081 48 0 _ , �i Of o mix �' O •t- �,It 4ss 1�, 4 c � t M Y ., .Ir?E p; . Pix N y�: it N 14�1 i �4 - —-. Tip . ti.1 ' IIC • © i i si'lio 8 I . EZ ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 OFFICE COPY Reissued August 2014 This report is subject to renewal August 2016. www.icc-es.org I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE pcf. The insulation's liquid components are supplied in PROTECTION nominally 55-gallon drums, labeled as "A" component or Section:07 21 00—Thermal Insulation "B" component. The insulation components have a shelf life of six months when stored in unopened containers at REPORT HOLDER: temperatures between 70°F(21°C)and 90°F(32°C). SES FOAM 3.2 Surface-burning Characteristics: 4008 LOUETTA ROAD,#538 At a maximum thickness of 4 inches (102 mm) and a SPRING,TEXAS 77388-4405 nominal density of 0.5 pcf, the insulation has a flame- (713)239-0252 spread index of 25 or less and a smoke-developed index of www.sesfoam.com 450 or less when tested in accordance with ASTM E84. Thicknesses of up to 111/2 inches (292 mm) for wall EVALUATION SUBJECT: cavities and ceiling cavities are recognized based on room corner fire testing in accordance with NFPA 286, when SES FOAM 0.5 lb SPRAY: SPRAY-APPLIED the insulation is covered with a minimum 1/2-inch-thick POLYURETHANE FOAM PLASTIC INSULATION (12.7 mm) gypsum board installed in accordance with the applicable code. 1.0 EVALUATION SCOPE 3.3 Thermal Resistance(R-values): Compliance with the following codes: The insulation has thermal resistance(R-values)at a mean • 2012 and 2009 International Building Codee(IBC) temperature of 75°F(24°C)as shown in Table 1. • 2012 and 2009 International Residential Code®(IRC) 3.4 Air Permeability: • 2012 and 2009 International Energy Conservation The insulation, at a minimum thickness of 3 inches Code®(IECC) (76 mm), is considered air-impermeable in accordance • Other Codes(see Section 8.0) with IRC Section R202, based on testing in accordance with ASTM E283. Properties evaluated: 4.0 INSTALLATION • Surface-burning characteristics 4.1 General: • Physical properties SES Foam 0.5 lb spray insulation must be installed in • Thermal resistance(R-values) accordance with the manufacturer's published installation • Attic and crawl space installation instructions and this report. A copy of the manufacturer's • Air permeabilitypublished installation instructions must be available at all times on the jobsite during installation. 2.0 USES 4.2 Application: SES Foam 0.5 lb spray polyurethane foam plastic The insulation is spray-applied at the jobsite using a insulation is used as a nonstructural thermal insulating volumetric positive displacement pump as identified in the material in buildings of Type V-B (IBC)construction, and in SES Foam 0.5 lb spray application manual. The insulation dwellings built under the IRC. The insulation is for use in components must be stored at temperatures between wall cavities and floor/ceiling assemblies, and in attics and 70°F (21°C) and 90°F (32°C) for several days before crawl spaces when installed as described in Section 4.4. application. The insulation must not be used in areas Under the IRC, the insulation may be used as air- that have maximum in-service temperatures greater than impermeable insulation when installed as described in 180°F (82°C). The insulation must not be used in Section 3.4. electrical outlet or junction boxes or in contact with water 3.0 DESCRIPTION (e.g., rain, condensation, ice, snow) or soil. The substrate 3.1 General: must be free of moisture, frost or ice, loose scales, rust, oil, grease or other surface contaminants. The insulation can SES Foam 0.5 lb spray foam insulation is a two- be installed in one pass to the maximum thickness. The component, open cell, one-to-one-by-volume spray-applied spray-applied foam insulation must be protected from polyurethane foam system with a nominal density of 0.5 weather during and after installation. ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed = ANSI as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as to any finding or other matter in this report,or as to any product covered by the report. <a'oi4o;Y:i Copyright®2014 Page 1 of 3 f ESR-3375 I Most Widely Accepted and Trusted Page 2 of 3 4.3 Thermal Barrier: 5.0 CONDITIONS OF USE SES Foam 0.5 lb spray insulation must be separated from The SES Foam 0.5 lb spray polyurethane foam plastic the interior of the building by an approved thermal barrier insulation described in this report complies with, or is a of 1/2-inch-thick (12.7 mm) gypsum wallboard or an suitable alternative to what is specified in, those codes equivalent 15-minute thermal barrier complying with, and listed in Section 1.0 of this report, subject to the following installed in accordance with, IBC Section 2603.4 or IRC conditions: Section R316.4, as applicable. Within an attic or crawl 5.1 The insulation must be installed in accordance with space, installation must be in accordance with Section 4.4. the manufacturer's published installation instructions, 4.4 Attics and Crawl Spaces: this evaluation report and the applicable code. If there are any conflicts between the manufacturer's 4.4.1 Application with a Prescriptive Ignition Barrier: published installation instructions and this report, this When SES Foam 0.5 lb spray is installed within attics and report governs. crawl spaces, where entry is made only for service of 5.2 The insulation must be separated from the interior of the utilities, an ignition barrier must be installed in accordance building by an approved 15 minute thermal barrier, as with IBC Section 2603.4.1.6 or IRC Section R316.5.3 or described in Section 4.3. Installation in an attic or R316.5.4, as applicable. The ignition barrier must be crawl space must be as described in Section 4.4. consistent with the requirements for the type of construction required by the applicable code, and must be 5.3 The insulation must not exceed the thicknesses noted installed in a manner so that the foam plastic insulation is in Sections 3.2 and 4.4. not exposed. SES Foam 0.5 lb spray insulation at a 5.4 The insulation must be protected from exposure to the minimum thickness of 3 inches(76 mm) may be installed in weather during and after application. unvented attics in accordance with 2012 IRC Section R806.5(2009 IRC Section R806.4), as applicable. 5.5 The insulation must be applied by contractors certified by SES Foam. 4.4.2 Application without a Prescriptive Ignition Barrier: Where the spray-applied insulation is installed in 5.6 Use of the insulation in areas where the probability of accordance with this section (Section 4.4.2) or Section termite infestation is "very heavy" must be in 4.4.3,the following conditions apply: accordance with 2012 IBC Section 2603.9 (2009 IBC Section 2603.8)or IRC Section R318.4, as applicable. a) Entry to the attic or crawl space is to service utilities, 5.7 Jobsite certification and labeling of the insulation must and no storage is permitted. comply with IRC Sections N1101.4 and N1101.4.1 b) There are no interconnected attic or crawl space and IECC Sections R303.1.1 and 303.1.1.1, as areas. applicable. c) Air in the attic or crawl space is not circulated to other 5.8 SES Foam 0.5 lb spray polyurethane foam plastic parts of the building. insulation is produced in St. Louis, Missouri, under a quality control program with inspections by ICC-ES. d) Attic ventilation is provided when required by IBC 6.0 EVIDENCE SUBMITTED Section 1203.2 or IRC Section R806, except when air-impermeable insulation is permitted in unvented 6.1 Data in accordance with the ICC-ES Acceptance attics in accordance with 2012 IRC Section R806.5 or Criteria for Spray-applied Foam Plastic Insulation 2009 IRC Section R806.4. Under-floor (crawl space) (AC377), dated June 2012, including reports of tests ventilation is provided when required by IBC Section in accordance with Appendix X of AC377. 1203.3 or IRC Section R408.1, as applicable. 6.2 Report of room corner fire testing in accordance with e) Combustion air is provided in accordance with NFPA 286. International Mechanical Code®Section 701. 6.3 Report of air permeance testing in accordance with In attics, the insulation may be spray-applied to the ASTM E283. underside of roof sheathing or roof rafters, and/or vertical 7.0 IDENTIFICATION surfaces, and in crawl spaces the insulation may be spray Components of the SES Foam 0.5 lb spray polyurethane applied to the underside of floors and/or vertical surfaces foam plastic insulation are identified with the as described in this section. The thickness of the foam manufacturer's name (SES Foam) and address; the date plastic applied to the underside of the top of the space of manufacture or the lot number; the product trade name must not exceed 12 inches(305 mm). The thickness of the (SES Foam 0.5 Ib); the mixing instructions; the density; the foam plastic applied to vertical surfaces must not exceed flame spread and smoke developed indices; and the 111/2 inches (292 mm). The foam plastic may be installed evaluation report number(ESR-3375). without a covering or coating. The insulation may be installed in unvented attics in accordance with 2012 IRC 8.0 OTHER CODES Section R806.5 (2009 IRC Section R806.4). The ignition In addition to the codes referenced in Section 1.0, the barrier in accordance with IBC Section 2603.4.1.6 or IRC products in the report were evaluated for compliance with Section R316.5.3 may be omitted. the requirements of the following codes: 4.4.3 Use on Attic Floors: SES Foam 0.5 lb spray • 2006 International Building Code®(2006 IBC) insulation mays be installed exposed at a maximum 2006 International Residential Code®(2006 IBC) thickness of 111/2 inches (292 mm) between joists in attic • floors. The ignition barrier in accordance with IBC Section • 2006 and 2003 International Energy Conservation 2603.4.1.6 or IRC Section R316.5.3 may be omitted. The Code®(2006 IECC) insulation must be separated from the interior of the building by an approved thermal barrier. pSR-33755 I Most Widely Accepted and Trusted Page 3 of 3 roducts comply with the above-mentioned codes as provided in accordance with Sections 701 and 703 of ed in Sections 2.0 through 7.0 of this report, with the 2006 IECC. ns as noted below: • Protection against Termites: See Section 5.6, except lication with a Prescriptive Thermal Barrier: See use of the insulation in areas where the probability of tion 4.3, except the approved thermal barrier must termite infestation if"very heavy" must be in accordance nstalled in accordance with Section R314.4 of the with Section R320.5 of the 2006 IRC. 6 IRC. ■ Jobsite Certification and Labeling: See Section 5.7, lication with a Prescriptive Ignition Barrier: Seeexcept jobsite certification and labeling must comply tion 4.4.1, except an ignition barrier must bewith Sections 102.1.1 and 102.1.1.1, as applicable, of alled in accordance with Section R314.5.3 orthe 2006 IECC. 4.5.4 of the 2006 IRC. lication without a Prescriptive Ignition Barrier: Section 4.4.2, except that combustion air is li TABLE 1—THERMAL RESISTANCE(R-VALUES''2) 11 THICKNESS(inches) R-VALUE(°F•ft2•h/Btu) 1 4.0 2 7.6 3 11 3.5 13 4 15 5 19 6 22 7 26 8 30 9 33 10 37 11 41 12 44 For SI: 1 inch=25.4 mm,1°F•ft2•h/Btu=0.176 110K•m2/W. 'R-values are calculated based on tested K values at 1-and 3.5-inch thicknesses. 2R-values greater than 10 are rounded to the nearest whole number. 0 11 41 EZ ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES VAR Environmental Report VAR-1030* Reissued July 2013 This report is subject to renewal September 1, 2015. www.icc-es.orq/ep I 800-423-6587 I (562)699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE high-pressure, plural component SPF application PROTECTION equipment. The bio-based content is as set forth in Table 1 Section: 07 21 00—Thermal Insulation of this report. REPORT HOLDER: 4.0 CONDITIONS 4.1 Code Compliance: SES FOAM See ICC-ES report ESR-3375 for compliance of the SES 4008 LOUETTA ROAD,#538 Foam 0.5 lb Foam S Polyurethane Foam Plastic Insulation SPRING,TEXAS 77388-4405 with code requirements. (713)239-0252 www.sesfoam.com 4.2 Green Codes, Standards and Rating Systems Eligibility: EVALUATION SUBJECT: The information presented in Tables 2 through 5 of this report provides a matrix of areas of evaluation and SES FOAM 0.5 lb SPRAY POLYURETHANE FOAM corresponding limitations and/or additional project-specific PLASTIC INSULATION requirements, and offers benefits to individuals who are assessing eligibility for compliance. 1.0 EVALUATION SCOPE The final interpretation of the specific requirements of the Compliance with the following environmental criteria: code rests with the Authority Having Jurisdiction. ICC-ES Environmental Criteria for Determination of Compliance for items noted as "Verified Attribute" is Bio-based Material Content(EC102),dated March 1, 2012. subject to any conditions noted in the tables. Decisions on Compliance eligibility with the applicable sections of compliance for those items noted as "Eligible for Points" in the following codes and standards: Tables 2 through 5 rests with the user of this report, and those items are subject to the conditions noted. The user is • 2012 International Green Construction CodeTM (IgCC) advised of the project-specific provisions that may be (see Table 2 for details) contingent upon meeting specific conditions, and the • ASHRAE Standard 189.1 – 2009 (see Table 3 for verification of those conditions is outside the scope of this details) report. • National Green Building Standard (ICC 700-2008) (see Due to the variability of costs and volume, the bio-based Table 4 for details) content percentage listed in this report is based upon weight (mass). The use of cost or volume as the method • ANSI/GBI 01-2010, Green Building Assessment for calculation is outside the scope of this report. Protocol for Commercial Buildings (see Table 5 for details) 5.0 BASIS OF EVALUATION 2.0 USES The information in this report, including the "Verified Attributes," is based upon submission of documentation SES Foam 0.5 lb Foam S Polyurethane Foam Plastic demonstrating compliance with the requirements set forth Insulation is used as nonstructural thermal insulating in ICC-ES EC102. (Evaluation applies to IgCC Section material in wall cavities, floor/ceiling assemblies, or in 505.2.4, item 3; ASHRAE 189.1 Section 9.4.1.3; ICC 700 attics and crawl spaces. See ICC-ES report ESR-3375 for Section 606.1;ANSI/GBI-01 Section 10.1.2.2.) more information on uses and applications. 6.0 IDENTIFICATION 3.0 DESCRIPTION Containers of SES Foam 0.5 lb Foam S Polyurethane SES Foam 0.5 lb spray-applied polyurethane foam plastic Foam Plastic Insulation are identified by a label bearing the insulation is a two-component, open-cell, water-blown, SES Foam name and address, product name, spray-applied polyurethane foam (SPF) with a nominal manufacturing date, manufacturing location and the VAR density of 0.5 lb/ft3. The foam is sprayed in place using Environmental Report number(VAR-1030). *Corrected May 2014 ICC-ES Verification of Attributes Reports are issued under the ICC-ES VAR Environmental Program.Mese reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC ! Evaluation Service,LLC,express or implied.as to any finding or other matter in this report,or as to any product covered by the report. S3=z MI OM.in Copyright®2014 Page 1 of 2 VAR-1030 I Most Widely Accepted and Trusted Page 2 of 2 TABLE 1—BIO-BASED MATERIAL CONTENT SUMMARY PRODUCT NAME %MEAN BIO-BASED CONTENT METHOD OF DETERMINATION SES Foam 0.5 lb Spray Polyurethane Foam Plastic Insulation 17%(+/-3%)' ASTM D6866 Note: 'Based on precision and bias cited in ASTM 06866. TABLES 2 THROUGH 5 Section Possible Number Section Intent Points Conditions Of Use To Qualify For Points Finding TABLE 2—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2012 INTERNATIONAL GREEN CONSTRUCTION CODE Bio-based materials shall be those materials that comply with one or more of the following: 505.2.4 Bio-based content N/A 3.The requirements of USDA 7CFR Part 2902. • Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 3—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2009 ASHRAE STANDARD 189.1 A minimum of 5%of building materials used,based on cost,shall be biobased products. Biobased products shall comply with the minimum biobased contents of the USDA's Designation of Biobased Items for Federal Procurement[7 CFR Part 2902],contain the 9.4.1.3 Biobased products N/A "USDA Certified Biobased Product"label,or be composed of solid wood,engineered wood,bamboo,wool,cotton,cork,agricultural fibers,or other biobased materials withat • least 50%biobased content. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 4—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2008 NATIONAL GREEN BUILDING STANDARD(ICC 700) The following biobased products are used: (h)products with the minimum biobased contents of the USDA 7 CFR Part 2902 606.1 Biobased products 3 (i)other biobased materials with a minimum of 50 percent biobased content(by weight 8 max or volume) • Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 5—SUMMARY OF AREA OF ELIGIBILITY WITH THE ANSI/GBI–01(2010)STANDARD Bio-based products accounted for 1%or more of the materials used in the building. Percentage=100 x A=B,where: A=Total cost or weight of bio-based products B=Total cost or weight of all building products 10.1.2.2 Materials content– 1 Cost or weight must be used consistently • Assemblies 7 max For USDA-designated products,products meeting or exceeding USDA's bio-based content,criteria or qualifying as USDA"BioPreferred"were used. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. • =Verified attribute .T.EZ ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 Seal and Insulate with ENERGY STAR®Supplement Reissued August 2014 This report is subject to renewal August 2016. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council° DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section:07 21 00—Thermal Insulation REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD,#538 SPRING,TEXAS 77388-4405 (713)239-0252 www.sesfoam.com EVALUATION SUBJECT: SES FOAM 0.5 lb SPRAY: SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 EVALUATION SCOPE Conformance to the following: Seal and Insulate with ENERGY STAR') Program—Definitions and Testing Requirements for Residential Insulation, Version 1.0 Properties evaluated: • Thermal resistance • Surface-burning characteristics 2.0 PURPOSE OF THIS SUPPLEMENT This supplement is issued to certify that the insulation products described in Sections 2.0 through 8.0 of the master report ESR-3375 have been reviewed for compliance with the requirements of the Seal and Insulate with ENERGY STAR Program, as set forth in the document Definitions and Testing Requirements for Residential Insulation, Version 1.0. The insulation product covered by this supplement is defined as"Spray or Pour Foam Insulation." The requirements for testing laboratory qualification and product sampling, as well as the specific material and test standards and editions used in this evaluation, are as set forth in the applicable documentation noted in Section 6.0 of the master evaluation report. 3.0 DEFINITIONS The following definitions are from Definitions and Testing Requirements for Residential Insulation, Version 1.0, and are applicable to the subject of this report. 3.1 General Definitions: Insulation: Any material mainly used to slow down heat flow. It may be mineral or organic, fibrous, cellular, or reflective (aluminum foil). It may be in rigid, semi-rigid,flexible,or loose-fill form. 3.2 Insulation Product Definitions: Spray or Pour Foam Insulation:A thermal insulating material that is sprayed or poured (as a gel or foamy liquid) into place, and expands or sets into a cellular foam and cures at the point of installation through a chemical reaction. Foamed materials include, but are not limited to polyurethane, polyisocyanurate, phenolic, and cementitious insulation. 3.3 Insulation Performance Definitions: R-value:The inverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces, under steady state conditions, per unit area. For the purposes of the Seal and Insulate with ENERGY STAR®program, Imperial units will only be accepted[(h•ft •°F)/Btu]. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report ora recommendation for its use.There is no warranty by ICC Evaluation Service.LLC.express or implied,as to any finding or other matter in this report,or as to any product covered by the report. tag, Copyright 0 2014 Page 1 of 6 • ESR-3375 I Most Widely Accepted and Trusted Page 2 of 6 Smoke-Development Index: The characteristic of a material to emit smoke when exposed to flame or fire compared to red oak and inorganic cement. Flame-Spread Index: The characteristic of a material to resist the spreading of flames when exposed to flame or fire compared to red oak and inorganic cement. 3.4 Thermal Resistance: The insulation has the thermal resistance R-values as noted in Table 1 of ESR-3375, based upon testing. 3.5 Installation: 3.5.1 General: The installation of the insulation must be in accordance with the requirements set forth in Sections 4.0 and 5.0(as applicable)of ESR-3375.The insulation is manufactured on-site by spray polyurethane foam applicators meeting the qualification requirements of SES Foam. The following information on personal protective equipment and ventilation requirements is reprinted from the SES Foam published installation instructions: "F. SAFETY 3. PERSONAL PROTECTIVE EQUIPMENT(PPE): a. Skin: Wear gloves, coveralls, apron and boots as necessary to prevent contact of liquid components or partially-cured SPF with skin.When handling liquid components, gloves should be made of nitrile, neoprene, butyl or PVC. b. Eyes: Protect eyes while handling liquid components or spraying with safety goggles or safety goggles and a face shield. During spray application, eye protection may be provided by a full-face or hood respirator. c. Respiration: Firms engaged in the application of SES Foam systems must have a written respiratory protection program for employees engaged in handling or applying SES Foam materials. Depending on the situation, respiratory protection may include dust masks, air-purifying respirators (APR), powered air-purifying respirators (PAPR), or supplied- air respirators(SAR). 4. VENTILATION: Provide ventilation and other engineering controls to exhaust vapors from work areas and to protect building occupants and other trades." 3.5.2 Occupancy Time after Installation: The re-entry or re-occupancy time shall be in accordance with the manufacturer's installation instructions,which state the following: "E. RE-ENTRY SES Foam 0.5 lb Spray reacts and cures within seconds of application. Re-entry times will vary depending on factors including ventilation. Typically, ventilation is continued for 24 hours following the conclusion of spray application and re-entry may occur at that time." 3.5.3 Figures:The figures shown represent general installations of the insulation in the following applications: above-grade wall, below-grade wall, vented and unvented crawl space, unvented cathedral ceiling, and vented and unvented attic. These figures are for illustration purposes and are not to be construed or used as construction documents. This supplement expires concurrently with the master report, reissued August 2014. ESR-3375 I Most Widely Accepted and Trusted Page 3 of 6 X 000000,0000000 °OOOpO°000000°00000000p000 00%0000°000o% 00°000000°00°00°0,°000°°°0 00000°00000 0 0p°o0o 000 00 00 00000000 0 ^00000°0 000000° Q°-n° 0000°0°0 0ogo 01,0:0°<;' 0 0 n OnO�°0° 000„00 0,000-00 v00°"00 . �O 00° 0, )0 0°00°°a 09 0 0�, Interior Partition 00°00000 °000°0°°( X00-00 -_Interior Finished Surface ,0000000 (1/2-inch Sheetrock) Soo00 00c 0 )000000 aoo°o°oo SES Foam 0.5 lb Spray I *2:*: °0000000 00� Exterior Sheathing 0 0°000°0 0° 0 0 0°�oo0oa 0 SES FOAM 0.5 LB SPRAY ABOVE GRADE WALL INSULATION SES 05-1 071812 ESR-3375 I Most Widely Accepted and Trusted Page 4 of 6 000. ' Masonry Block 0<> (Typical)---.._ ��1/ 1 ' ' ,0 �-_ Interior Finish Surface �/; (1/2-inch Sheetrock) o. 1 2"x 4"Studs ,I` .,: SES Foam 0.5 lb Spray Te. ..**:,:.''';!.. J.:•:.:...:,, 4-<.• \/ '' . '.,..-::•:: • V / • SES FOAM 0.5 LB SPRAY I BELOW GRADE WALL INSULATION I SES 05-2 I 071812 (Insulation on Interior Side of Wall) Baffle to provide // air space between // Thermal insulation and roof jj/ Barrier' deck. /j (as required //j// by local code) , eli• .A /// o000000000000000 000000000000000000000000. / 00000000000000000000.000000000000000000000000; /�'' 0.000o0o000000000opoO ,0000000000000000000000 000000 0'0000<oc 000000 A 00000000, o�o�o�o�< SES Foam 0.5 lb Spray ogegogog< j0!!llOOilOi!//.4K07!!OO!!!i/O/!!!/liiiii!!///!. 000000000i 00000000t 00000aooc 00000000, 0 0 0 o c 00000000c 0000000ac 0 0 0 o c 000000000 0000000(< O O O Vented Soffit g%ggog8� 0o00000o< ogogogog< 40:0:0:C `Where attic entry is for the 00000000e 00000000< service of utilities only,thermal SES Foam 0.5 lb Spray 00000,00< gogogogo4 and igniton barrier on the attic °�1,4 side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY VENTED ATTIC:FLOOR/SOFFIT SES 05-3 071812 ESR-3375 I Most Widely Accepted and Trusted Page 5 of 6 °,,; Subfloor SES Foam 0.5 lb Spray v.1.::gi:i ►tet °°° C,�oV ;4 48gSg8g°°°g4.4: s°° °° eoo°°o°go,e°g,o,°°e°°, a a°°°g°°°°°°°°°°°°°gog S° � Header °°°°o°e°p°°°•°• °::uo�o�v,viosa► .. , ,., ,,` _ 1 ey°°° <Pg 11 000� 1111 Sill 1����v ► °°°°° Joist Floor Cross Section • 04 Thermal Barrier* M. . - A (as required by Exterior Grade p�i 1X local code) ii4 ►�i�i�i�i.1 6"Min ►• I ►����4 ♦���♦ Footer---,.._ ► 4 Vapor Barrier \//\// /` is for ' //\\/\// /► service of utilities oven thermal the • ; : / // // A and igniton barrier on the crawlspace side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY CRAWLSPACE:VENTED SES 05-4 071812 A ii o Subfloor °°° °°°° ►�. 8°_lIII°Header gg°o°%°S°%.11 liggligqiit Sill io° Joist ►����j�j4:44 Thermal Barrier* ►•.•.•�•.4.1.:02. (as required by Exterior Grade j����-�800g8 local code) //\\ ,\\//2\\ 40 eo.o �:O:': SES Foam 0.5 lb Spray ►����• 4$$a • .•w Footer--,........ !„ : 6"Min Vapor Barrier �/ *Where crawlspace entry is for the service of utilities only,thermal and ignitors barrier on the crawlspace side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY CRAWLSPACE:UNVENTED SES 05-5 071812 • ESR-3375 I Most Widely Accepted and Trusted Page 6 of 6 Note:In cold climates,embed metal connector plates in spray foam to prevent winter-time condensation. SES Foam 0.5 lb Spray oo°°o° l• ' °g000 o°°°°o• ° omoo'. i o0 ° Roof Sheathing °°°o° i `°o t" o/ .°o°oo°o Truss Top Cord/ ,000°°°°. Rafter ,,,— ° nnnnnn nnnnnn Imo__ flnn� IA- Thermal Barrier' (as required by local code) I Note:Local building code may 1 require the use of a vapor retarder 'n cold climate zones. Ceiling/Thermal Barrier 'Where attic entry is for the as required by local building code. service of utilities only,thermal and igniton barrier on the attic side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY UNVENTED ATTIC/INSULATED ROOF DECK SES 05-6 071812 /o o .,00�o ioo0o - SES Foam 0.5 lb Spray O O 00• 00O 0 04 to specified thickness. • O • .7O O Roof Sheathing •O O • 000000 • 1• 0 0 0 0 0. ' Thermal Barrier as Rafter e•O O O ' required by code. •O Note:The local building code I amayva rogbarrthe installation tof o a vapor barrier in cold climate zones. SES FOAM 0.5 LB SPRAY CATHEDRAL CEILING SES 05-7 071912