Loading...
1756 ATLANTIC BEACH DR - NEW HOME PERMIT (---. ; . s CITY OF ATLANTIC BEACH 2 800 SEMINOLE ROAD -TIF .__j-zy ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 SINGLE FAMILY DWELLING NEW MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFR-2081 Job Type: SINGLE FAMILY RESIDENCE Description: new single-family residence Estimated Value: $357,152.00 Issue Date: 10/13/2016 Expiration Date: 4/11/2017 PROPERTY ADDRESS: Address: 1756 ATLANTIC BEACH DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: TOLL BROS.,INC , CGC 1510225 Address: 250 GIBRALTAR RD STEVEN R MERTEN Phone: - - PERMIT INFORMATION: FEES: ENG REV RESIDENTIAL BLD $100.00 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $1,251 .46 STATE DCA SURCHARGE $18.77 PLAN CHECK FEES $625.73 STATE DBPR SURCHARGE $18.77 EII I�` f'12��,f IY()�TT" INQAVIZI)1NCE` 'IO15OI.P9:ITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA NG CODES. S y]J�f •\ rf\SCITY OF ATLANTIC BEACH ;_, 800 SEMINOLE ROAD -4::) ' y" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 0321 9f= WATER CONNECT/TAP & $185.00 METER WATER CROSS CONNECTION $50.00 WATER SDC-SYSTEM DEV $1,140.00 CHG WATER CONNECT/TAP & $185.00 METER Total Payments: $7,674.73 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. � ;s�L�f., City of Atlantic Beach � � BuildingDepartment APPLICATION NUMBER t� p (To be assigned by the Building Department.) 8tl0 Seminole laBeach, FloridaAtlantic rii32233-5445 I(0 -S Fg. a 011 y - Phone(904) 247-5826 • Fax(904)247-5845 \._.-19,1511;„/ E-mail: building-dept@coab.us Date routed: 9 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I1-Cb C—knIa. De artment review required Yes No nn uildin Applicant: �� e (OS. 1IiL • ,Planning&Zoning Tree Administrator Project: 1\&AZ s �� 1�- cM t tAi C.OoSil miLki,iY\ ubl Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle on-. Comments: :UILDING /�}� 9'2;76 PLANNING&ZONING Reviewed by: c - / / Date: TREE ADMIN. Second Review: ['Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. Comments: Reviewed by: Date: of Atlantic_Beach -Building Department APPLICATION NUMBER---- , (To be assigned by the Building Department.) IA ,�) 800 Seminole Road ,. Atlantic Beach, Florida 32233-5445 ((q —S FR._aQ Phone(904)247-5826 Fax(904)247-5845 Q µort �r y E-mail: building-dept@coab.us City web-site: http://www.coab.us Date routed: f/b Ii APPLICATION REVIEW AND TRACKING FORM Property Address: I.1•g-19 A-NAO.- M C. Bt..tt.CilNi. Department review required Yes No :uildin• Applicant: TO S (0S.) L • Planning &Zonin. ` �• Tree Administrator Project: 1\ 2AZ 5 t,f1A`�- M 1 (AnSit�1�11� ub rk- Public Utilities Public Safety Fire Services Review fee $ Dept Signature • Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ,Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: � � C��—pate: 17/241/4( TREE ADMIN. Second Review: Approved as revised. ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: DApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 City of Atlantic Beach . __ • ,---- -- -- — APPLICATIONNUMBER -- i . Building Department ^C iVF: ---7.41',,r;; 800 Seminole Road �-� (To be assigned by the Building Department.) !:�`; V Atlantic Beach, Florida 32233-54 SEP 16 2016 , g -- t S Fga ow Phone(904)247-5826 - Fax(90 ) 47-5845 ',o f g- E-mail: building-dept@coab.us ,•, Date routed: Ii(p (p City web-site: http://www.coab.usBY: ii APPLICATION REVIEW AND TRACKING FORM Property Address: 1 i(i h-k-k&Ai L BIALAAliNi, Department review required Yes No puildin. Applicant: TO tk 2 (OS., liAc_ • Planning &Zoning Tree Administrator Project: I\amu) S l,rl kit,- Vr(1.tn t toti C,pv)sit t( y\ ublic..Wnrks Public Utilities Public Safety Fire Services ,Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers - Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: (Approved. a f-1ti1` ❑Denied. (Circle one.) Comments: r BUILDING floe i �/�i 44010691 PLANNING &ZONING �C q Reviewed by: Date//3d/j4 TREE ADMIN. Second Review: ❑Approved as revised. ❑ enied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: DApproved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 /9c' fld /' 0,/ //cX s'_ 4‘57,z4.- /37 67/ x - - -t / r , ? X 29 _ If 9 ,z/,1 g9,J'"X 7 z 40' �� << 1 r r _ Y (V ,514 p r6 LP'VG x`/1 - -r'-( ' 7-/G '1 . . __ City of Atlantic_Beach APPLICATION NUMBER-- esit: Building Department E C E 11\1E' (To be assigned by the Building Department.) 800 Seminole Road 1.? Atlantic Beach, Florida 32233-544 16 2016 {(0 �5 FR.—a o• Phone(904)247-5826 • Fax(90 7-K, u of >r E-mail: building-dept@coab.us Date routed: cJ J/'p ' IO City web-site: http://www.coab.us BY: APPLICATION REVIEW AND TRACKING FORM Property Address: 11-g19 Ack1O4.nti L It cii 1 1. De artment review required Yes No pp Buildin e Applicant: Tt7 11 (OS., Planning&Zoninn Tree Administrator Project: 1\itAZ V M s(Ai CO‘ASii t , \ ub Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING lA Reviewed by: Date:14 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. CI Denied. Comments: Reviewed by: Date: Revised 07/27/10 I trLff � ` i ,� ` . `S CITY OF ATLANTIC BEACH ,.i„: 0 PUBLIC UTILITIES y V 1200 Sandpiper Lane ATLANTIC BEACH,FL 32233 .-J'31 PY (904) 270-2535 or(904)247-5874 NEW WATER/SEWER TAP REQUEST Date: 1/2.4 1)6 Project Address: 7 6i+-7-("/17L (3I DiZ. No. of Units: 1 Commercial Residential ✓ Multi-Family ..., r' New Water Tap(s)&Meter(s) Meter Size(s) 'i=f New Irrigation Meter V Upgrade Existing Meter from to (size) New Reclaim Water Meter 7 Size 3/4 'New Connection to City Sewer 7 Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# /6 ` S Fta.' 24,1 • Water System Development Charge $ f/1 140 ,o0 •Sewer System Development Charge $ y, o So,00 • Water Meter Only $ /gs:v, • Reclaim Meter Only $ /gr-oo Water Meter Tap $ (notes) Sewer Tap $ • Cross Connection $ AO Other $ TOTAL $ 6(0 .00 APPROVED: Kayle Moore.PE )Z11,1_ (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH OFFICE COPY 800 Seminole Road,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 // �j Job Address: 1756 Atlantic Beach Drive:Atlantic Beach,FL 32233 Permit Number: /U S'F', --c2(co- Legal Description Lot 72 Atlantic Beach Country Club Unit 02 67-132-08-2S-29E.148 Parcel Floor Area of Sq.Ft. Sq.Ft Valuation of Work$ 357 152 Proposed Work heated cooled 3,120 non-heated/cooled 908 Class of Work(circle one): co Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed?(Circle one): N/A Florida Product Approval#See attached For multiple products use product approval form _ {l Describe in detail the type of work to be performed:New Residential Construction , ,,, ,,,,,\ ,_,.. Property Owner Information: Name:TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Aven 2' \C:11 City Ponte Vedra State FL Zip,32081 Phone 904 217-0739 �e E-Mail or Fax 4(Optional)arogers n�?tollbrothers.com CJ Contractor Information: CONTRACTOR EMAIL ADDRESS: arogers'2)tollbrothers.com Company Name:Toll Bros..Inc.Qualifying Agent:Steven R.Merten,Division Sr.Vice President Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 , Office Phone 904 217-0739 Job Site/Contact Number 904 386-6472 Fax# State Certification/Registration 4 CGC 1510225 Architect Name&Phone# — 1 1 . Jar 1• ■i" /tor Z "',�i • Engineer's Name&Phone# , grAWI`I arlaMOLMang(oi Fee Simple Title Holder Name and Address RC)II FL VI U 1V11 r d Foy+) 16rShip Bonding Company Name and Address N A Mortgage,Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months,or if construction or work is suspended or abandoned for a period of six(6)months at any lime after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells,Pools,Furnaces,Boilers, Heaters,Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whethe pectjted herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state.or loc regulating construction or the performance of construction. Signature of Owner Signature of Contractor 41 Print Name Steven R.Merten,Division Sr.Vice,President_ Print Name Steven R.Mertes,Division Sr.Vice President Before me Before me this Day of July .2016 this 22 •ay of July .2016 E0 L4. • r . !' 1�rCli A k AI& Al t" I )L\JRI o . Publi. • b is , Revised 01.26.10 ;;;"' ASHLEY ANN ROGERS •'i MY COMMISSION#GG019753 `'"` ; ASHLEY ANN ROGERS • a,ti EXPIRES August 09,2020 '*: ' MY COMMISSION#GG019753 "' ;.� EXPIRES August 09,2020 OFFICE COPY DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions Review Initials/Date: /77,), Development Size Habitable Space 3)10 3,i=' Non-Habitable 70 SI s. Impervious area Miscellaneous Information Occupancy Group g -5 Type of Construction V 6 Number of Stories 2 Zoning District A 6c- Max. Occupancy Load Fire Sprinklers Required Flood Zone X Conditions/Comments: • OFFICE COPY R.O.W.Permit Attachment of for R.O.W.Permit# issued ,20I6 Atlantic Beach,FL 32233 Owner's Name: Toll FL VI,LP Property Address: 1756 Atlantic Beach Drive Atlantic Beach,FL 32233 Subdivision: Atlantic Beach Country Club Lot#/Block#: 72 R.E.#: 169505-1655 REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this day of ,20 ,by Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and Toll FL VI,LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30)days notice by CITY to the USER,said notice to USER shall be given by certified mail,return receipt requested,to the following address: 160 Cape May Ave.Ponte Vedra,FL 32081. The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating,replacing,or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes,Land Development Code,and all other land use and code requirements of the CITY,including City Code Section 19-7 (h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page lof2 `✓ �� 16 V a �O O Q 1 I I OFFICE COPY The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall,at the discretion of the CITY,be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. DATED and S r.i TED this .=), x day of J U t\-/ ,2016. By: 10 St: :marten,Division Sr.Vice President,Toll FL VI,LP. (t-,be signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this 22nd day of July ,2016,personally appeared before me,a Notary Public in and for said County and State, St.Johns,Florida ,the property owner of 1756 Atlantic Beach Drive,Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instru who acknowledged to me that he or she executed the same freely and voluntarily and for the use• .�i . ..ses therein mentioned. ,yii"" ;. ASHLEY ANN ROGFRS j di OA- AI . ., •'5 MY COMMISSION#GG019753 NotaryPublic in .•sat"Coun and State ��" tY '•.,,o,' ,: EXPIRES August 09,2020 CITY OF ATLANTIC BEACH,FLORIDA,a municipal corporation: Approved: Doug Layton,Public Works Director For Permits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 N -- O sD 00 -.] CT In W N CO O\ V, W tJ 'a ',..<O U PfiIIIH =C- CDn: 1It Q" 93 = Uo ir -o u4 C a, Q4 v, (J4 C/) Cl) 0 a U4 'n a. Z U4 a cr o (-5 N 0 CD d CD . • 3 a. v, coo a. 0 s� a0 -I m P. V. C C • O = C CS • -- (n3 cr o v,• V, 7 O O S S l+ A CCI .,- H H '-� H .Do .a W T.' [J Ca "'� x tJ .� S) O C ry o o a. 0. n CD ,H n_ -t 0 �" o b tJ O = ?» Z �' a 0 4 f `D Q' a• cox1 ✓ o u n s m O < -o 0 C • ° y Y CD a a ro o o n <i �1 00 O\ cn A w N — O sO oo J to A w N -- C) O Do v o. LA A w N n a o cno 0• o `C o o o o o Z 7� •a w w c o rrl o -nom y r) C' O p .c O O W O O UG a. y O a. 't7 O S < O w cn ,_ c 't (n �' ~ `< '-h a. Q. f Dt 7 lD '=1 C ^i •-, P.)G O Oi7.CD O' o �' ` UGtii a9 ✓ �o sv UG 9 UG U� v n ° UG,, < y z �• w o C" o t7 N r O N O O U = UQ c O O ~ a' O n O p> > Ar A� _ A ;: w Dn o C7 oc UG C S 0 r co •e_..... ` O Tm O T ( O -n -,' S ry 7' ry V) Oo O� � CQ. Q. - c tn t.n b CO v• - _ 1.' r' p' a. a. �. C) �;, 0 (ID (1G o r n O O a a. 0. "' C C 3 7 a a OctV) Xi a a >, w a. a a. = OC -, aD Pr c ry (a CD(; t1_ Ew cn en v� P.) 4) 7.' in w O O X 10 r, . 7 a a a a n y C) �' �' (n a Y UG UG 'Zr C) C b a ca "0.-s. 00 v, — 0 / z: . ZZZ ZZZ Z 0 z 0 C (n CD "r1 "r1z; -n' •n - -n -n r r r- r-- t- . rr � rr (J _ —1 _. I- w N • . co 0 o N w v, N (., 4- J - w - O O N • O 7-. N O \O O\ - '0 O -1 4- �, J • ? 00 co vi co IJ V. -. IJ .- -. - W hJ 0. O N v, O -- it - SID ‘0 Go N • 4- O 4:_ • n a J — M x tJ C) W IJ — O � 00 �] C\ CA A W N — n ....1 J ON In ? W N M -I a C O cp V7 '0 o z (-) (7 7o m -3 O v) O :4 c� to y v) o -, a C17 CZ:i • c w $ as 2 0 s ° ° 8 a• 0 0' O a C" to . m Nva 2 v n O C 2 v m• .a a '-3 Qq a -, a ,b �7 '" 0 a CD w a Z r) a a a -�3 0 Lai ,n 6. A) O '.1" ^� p C. a n to co Z �" N Z CA vdi ZI Z cn N 3 ° c Oma, c N0 IQ v', O S -, G 'v rn 0 c o v: C) ) v , H o a < cON = o . _-J oi yN ..7: _ H a' -0 TD u) N r (IQ c° to a Co o m a a a O 7M ti a < a nU 0 v a O 0 3--. < A -'' CD a C 7 v) a C) n va '^a p) CD --i f. a- Q0) -, CD N . ..t O N O 5 a vt C 07 CDo 0 a' O O CD N 0 -i P = fl. CD cm O 0 EF a CD aa 0 o a• tom., -a m H :n -0 73Ct C) va 2 ° o < n ,,, g a. o CD e> v' r -o CD a `< B a- n F CJ a" O 3 N tti -, - N O v; < a 0 O• a — Coa a- g. o- _, -t m -s_ 0 f.M -0• ri Fj CD a CD a ' o $ . o a _i O' n CD• a a o o' o '"' a a C to CD m a- a DI co a. -o -^ --i• -o -o r a CD ut FJ SS r o a — P) t ) ON a• w CAa a' fD (r. Oa 3k 0 0 n a n / n ¥ / - k k / 0 E Q 7 / 2 ° 2 > < E \ Z ? \ ) 0 \ / / ® 3 } .. 7 § ƒ R / n ri < ~ ° _ .. ± 0 § 0 © RQ k. k ..--. 2 /= oo 2 n CO / ON 2 k f « CT' \ \ . p co / - > G R ) \ 2 (lc ¢ \ to (Ikd \ O \ / E n' k § x g 0 F. \ 7 CIQ Z c 0. \ = ., r CD . . § �E M f \ o \ (n n c / & .... \ % \ / 4 co" \ ) e r111111,Di qb. ƒ / c \ OFFICE COPY • FORM R405-2014 ' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION 1 Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Davenport 3120 Right NE Builder Name: Toll Brothers Inc. Street: 1756 Atlantic Beach Dr.(Lot 72 AB) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) I . 1. New construction or existing New(From Plans) 9. Wall Types(3496.9 sqft.) Insulation Area a.Frame-Wood, Exterior R=19.0 3321.40 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 175.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 4 d.N/A R= ft' 10.Ceiling Types (2310.0 sqft.) Insulation Area 5. Is this a worst case? No • a.Under Attic(Vented) R=38.0 1975.00 ft' 6. Conditioned floor area above grade(ft') 3120 b.Under Attic(Vented) R=19.0 335.00 ft2 c.N/A R= ft' Conditioned floor area below grade(ft2) 0 11.Ducts R ft' 7. Windows(470.6 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 550 a. U-Factor: Dbl,U=0.33 470.56 ft2 SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A ft' a.Central Unit 48.0 SEER:14.00 SHGC: . c. U-Factor: N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency • d. U-Factor: N/A ft' a.Electric Heat Pump 48.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.253 ft. 14.Hot water systems Area Weighted Average SHGC: . 0.300 a.Natural Gas Tankiess Cap:1 gallons 8. Floor Types (3120.0 sqft.) Insulation Area EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2310.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 790.00 ft2 None c.other(see details) R= 20.00 ft' 15.Credits Pstat i Total Proposed Modified Loads: 74.88 PASS Glass/Floor Area: 0.151 Total Baseline Loads: 80.35 t I hereby certify that the plans and specifications covered by Review of the plans and F,040 .1,HE ST,4 444>� this calculation are in compliance with the Florida Energy specifications covered bythis ti �� 5 O calculation indicates compliance co /i,, Code. / / with the Florida EnergyCode. �"''1 �''-�!'''°'`'� h «rru.n , 0 • PREPARED BY: ( `"'r' Before construction is completed $$ '� l-...-x---.7:' DATE: 0S4lIBLe this building will be inspected for 1 tt,A.i.compliance with Section 553.908 .` a '•Florida Statutes. I hereby certify that this building -s designed,is in compliance Q5 with the Florida Energy Code. n ) �e.4.°0 WL ,0 OWNER/AG T: /� / BUILDING OFFICIAL: �! ' DATE: 111110 - DATE: 9' /6 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulatign Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software PPP 1 of 5 FORM R405-2014 PROJECT Title: Davenport 3120 Right NE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3120 Lot# Owner: Toll Brothers Inc. Total Stories: 2 Block/SubDivision: . #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Inc. Rotate Angle: 0 Street: 1756 Atlantic Beach Dr. Permit Office: Atlantic Beach Cross Ventilation: No County: Duval I Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range - V FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume • 1 Block1 3120 30390. SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2310 23100 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 810 7290 No 1 1 1 Yes Yes Yes FLOORS , V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet i// 1 Slab-On-Grade Edge Insulatlo Main 214.6 ft 0 2310 ft2 ____ 0 0 1 2 Floor over Garage 2nd Floor ____ ____ 20 ft2 19 0 0 1 3 Floor Over Other Space 2nd Floor ___ ____ 790 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch • V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) • V 1 Gable or Shed Composition shingles 2606 ft' 584 ft2 Medium 0.6 N 0.9 No 0 26.6 • ATTIC V # Type Ventilation Vent Ratio(1 In) Area RBS IRCC _ 1 Full attic Vented 300 2330 ft2 N N • • • 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type ✓ 1 Under Attic(Vented) Main 19 Blown 214 ft' 0.11 Wood ✓ 2 Under Attic(Vented) Main 38 Blown 1286 ft2 0.11 Wood V 3 Under Attic(Vented) 2nd Floor 38 Blown 689 ft2 0.11 Wood ✓ 4 Under Attic(Vented) 2nd Floor 19 Blown 121 ft2 0.11 Wood WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V #-Ornt T.o wail _T-ype Space Value-Et-In-Et-h Area R_Value-Fraction-Absor-Grade%-- ✓ 1 NE Exterior Frame-Wood Main 19 20 6 10 0 205.0 ft2 0 0.23 0.6 0 ✓ 2 NW Exterior Frame-Wood Main 19 77 0 10 0 770.0 ft2 0 0.23 0.6 0 ✓ 3 W Exterior Frame-Wood Main 19 7 2 10 0 71.7 ft2 0 0.23 0.6 0 V 4 SW Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.6 0 V 5 SE Exterior Frame-Wood Main 19 77 0 10 0 770.0 ft2 0 0.23 0.6 0 ✓ 6 NE Garage Frame-Wood Main 13 19 6 9 0 175.5 ft2 0 0.23 0.6 0 ✓ 7 NE Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 • ✓ 8 NW Exterior Frame-Wood 2nd Floor 19 20 3 10 0 202.5 ft2 0 0.23 0.6 0 V 9 SW Exterior Frame-Wood 2nd Floor 19 40 0 9 0 360.0 ft2 0 0.23 0.6 0 ✓ 10 SE Exterior Frame-Wood 2nd Floor 19 20 _ 3 9 0 182.3 ft2 0 0.23 0.6 0 DOORS V # Ornt Door Type Space Storms U-Value Ft Width In FtWidthArea _V- i NE Insulated Main None .4 3 8 24 ft2 2 NE Insulated Main None .4 2 8 8 21.3 ft2 WINDOWS • Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.33 0.3 36.0 ft2 7 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 ✓ 2 NW 2 Vinyl Low-E Double Yes 0.33 0.3 18.0 ft2 7 ft 0 in 1 ft 0 In Drapes/blinds Exterior 5 V/ 3 NW 2 Vinyl Low-E Double Yes 0.33 0.3 36.0 ft2 1 ft 4 In 1 ft 0 in Drapes/blinds Exterior 5 V 4 NW 2 Vinyl Low-E Double Yes 0.33 0.3 20.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 ✓ 5 W 3 Vinyl Low-E Double Yes 0.33 0.3 18.0 ft2 1 ft 4 in 1 ft 0 In None Exterior 5 1 V 6 SW 4 Vinyl Low-E Double Yes 0.33 0.3 36.0 ft2 9 ft 4 In 1 ft 0 in None Exterior 5 V 7 SW 4 Vinyl Low-E Double Yes 0.33 0.3 96.0 ft2 9 ft 4 in 1 ft 0 in None Exterior 5 ✓ 8 SW 4 Vinyl Low-E Double Yes 0.33 0,3 36.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Exterior 5 ✓ 9 SE 5 Vinyl Low-E Double Yes 0.33 0.3 54.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 IVB 10 SE 5 Vinyl Low-E Double Yes 0.33 0.3 6.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 v 11 SE 5 Vinyl Low-E Double Yes 0.33 0.3 36.0 ft2 1 ft 4 In 1 ft 0 in None Exterior 5 • 12 NW 8 Vinyl Low-E Double Yes 0.33 0.3 3.6 ft2 1 ft 4 In 1 ft 0 in None Exterior 5 ✓ 13 NW 8 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Exterior 5 / 14 SE 10 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 • • 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 . FORM R405-2014 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 444 ft2 444 ft2 43 ft 9 ft 1 INFILTRATION i # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000309 2532.5 139.03 261.47 .2934 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts ✓ 1 Electric Heat Pump None HSPF:8.2 48 kBtulhr 1 sys#1 , COOLING SYSTEM YP V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts ✓ 1 Central Unit Split SEER:14 48 kBtu/hr 1440 cfm 0.7 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF V None None ft2 DUCTS V # —Supply— --Return-- Air CFM 25 CFM25 HVAC# / Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool V 1 Attic 6 550 ft' Attic 287 ft' Default Leakage Attic (Default) (Default) 1 1 I I I I I I I I I 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FARM R405-2014 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ ]Jan (x)m) ]Mar Ixi,tp)rr [ Jun Jul ri Au Se Oct [xill',1Z Heating [X]Jan f X)Mar [ Jun Jul Au1 SeE A Oct fVenting [[ ]Jan Feb [XI Mar Apr May Jun Jul Aug Sep [X]]]Oct XNov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 88 78 78 78 78 78 78 80 80 80 80 i 0 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 68 66 68 68 68 68 68 66 66 Heating(WEH) PM 66 68 66 66 66 68 68 68 68 68 68 66 688 1 i I I i I f 1 I I • • 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 'FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) , DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. • 1756 Atlantic Beach Dr. (Lot 72 AB), Atlantic Beach , FL, t I 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area , 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=19.0 3321.40 ft2 b.Frame-Wood,Adjacent R=13.0 175.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 . 10.Ceiling Types Insulation Area 5. Is this a worst case? No • a.Under Attic(Vented) R=38.0 1975.00 ft2 6. Conditioned floor area(ft2) 3120 b.Under Attic(Vented) R=19.0 335.00 ft2 7. Windows" Description Area c.N/A R= ft' 2 a. U-Factor: Dbl,U=0.33 470.56 ft2 11•Ducts R ft a.Sup:Attic,Ret:Attic,AH:Attic 6 550 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 48.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency I I SHGC: a.Electric Heat Pump 48.0 HSPF:8.20 , Area Weighted Average Overhang Depth: 4.253 ft. Area Weighted Average SHGC: 0.300 1 8. Floor Types Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2310.00 ft2 a.Natural Gas EF:0.8 1 b. Floor Over Other Space R=0.0 790.00 ft2 c. other(see details) R= 20.00 ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ‘‘.v`Vii sTg7,,i, Construction through the above energy saving features which will be installed (or exceeded) / O .0.-,--t---.244 " .� ,,y. .,,c,, •.:i= oma'. in this home before final inspection. Otherwise, a new EPL Display Card will be completed 'v` •.•,, . ,ft g e:,,� r i based on installed Code com li.� atures. . Builder Signature: L� / / Date: 1,,/,�j a�7. .4-LIP Address of New Home: 11C:)(j antic Meth Of, City/FL Zip: AB,� 39x3,3 T ,14.�o m `.',�v5a,° .,,n„w,�...v *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 ' I , I FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 1756 Atlantic Beach Dr.(Lot 72 AB) Permit Number: Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information Indicating the energy performance level and efficiencies of components • Installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans • and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. VR402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; • 2.Dampers Including exhaust,Intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond Intended Infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. VR402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. pR402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,Independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. Yr R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. gi R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. J2J R403.2.2 Sealing(Mandatory)Ail ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified In accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,Including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Urnin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1.of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) r t� R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. fe R403.4.4 Water heater efficiencies(Mandatory). 5( R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum • temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 5r' R403.4.4.2 Water heating equipment. Water heating equipment installed In residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of • Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors In installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. yr R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system Is not operating. R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. VR403.6.1 Equipment sizing. Heating and cooling equipment shall be sized In accordance with ACCA Manual S based on the • equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not Include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that Its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn• Page 2 of 3 FORM R405-2014 • MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is Installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. Si R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system Is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. 0 R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall Include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. 0 R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and Inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently Installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 17{ V R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. P. R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type w concrete deck roofs do not have sufficent space,R-10 is allowed. 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Davenport 3120 Right NE Builder Name: Toll Brothers Inc. Street: 1756 Atlantic Beach Dr. (Lot 72 AB) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers Inc. Jurisdiction: 261300 - Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK i Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. I Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and / framing shall be sealed. / Rim joists Rim joists are insulated and include an air barrier. • Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside / and cantilevered floors) of subfloor decking. // The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently / attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. / Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or /// unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled / by insulation that on installation readily conforms to the available cavity ,/ spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be / air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in / exterior walls, or insulation that on installation readily conforms to available • space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air / barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or / air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be / sealed to the sub-floor or drywall. �/Z Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have t gasketed doors i 8/11/2016 9:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE • FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Davenport 3120 Right NE • Builder Name: Toll Brothers Inc. • Street: 1756 Atlantic Beach Dr.(Lot 72 AB) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: • Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 3120 sq.ft. Cond.Volume: 30390 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: i CFM(50): _ Single or Multi Point Test Data • HOUSE PRESSURE FLOW: I ELA: Eq LA: • ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour In Climate Zones 1 and 2,3 air changes per hour In Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 Inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other • Infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if Installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if Installed at the time of the test,shall be fully open. ........p.....gl.t I hereby certify that the above envelope leakage Where required by the code official, 0".c.11-1E • performance results demonstrate compliance testing shall be conducted by an �,. ti.•, �.__ with Florida Energy Code requirements in approved third party.A written .1f.' '` �� • accordance with Section R402.4.1.2. report of the results of the test shall •• .: be signed by the third party x'•, conducting the test and provided to SIGNATURE: the code official. 14/4/\ t , ,Qv wt,c3 „40 PRINTED NAME: DATE: BUILDING OFFICIAL: DATE: 8/11/2016 10:00 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 • McGowan' Project Summary Dae: 20-413Condilrtg Entire HouseBy: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email:smerten@tollbrothersinc.com Notes: The Davenport Bonus Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 37 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 31977 Btuh Structure 30139 Btuh Ducts 4354 Btuh Ducts 5649 Btuh 1 Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36330 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 35788 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4083 Btuh Ducts 967 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 3120 3120 Equipment latent load 5550 Btuh Volume(ft3) 30496 30496 Air changes/hour 0.28 0.15 Equipment total load 41338 Btuh Equiv.AVF(cfm) 142 76 Req.total capacity at 0.70 SHR 4.3 ton Heating Equipment SummaryCooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB048 Cond CH14NB048 AHRI ref Coil FB4CNP048 AHRI ref Efficiency 8.2 HSPF Efficiency 11.0 EER, 14 SEER Heating input Sensible cooling 32900 Btuh Heating output 47000 Btuh @ 47°F Latent cooling 14100 Btuh Temperature rise 31 °F Total cooling 47000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsofL' 2016-Aug-1108:23:53 �� Comfort Builder by Wrlghtsofl 17.0.03 RSU12270 page 1 ..on\Toll Brothers\Davenport Bonus 3120 Right.rup Catc=MJ8 Front Door faces:NE .0..— /1 \ First Floor 3'Fan, 6 x 10 1,, 6.. M.Bath 14" 14' Master 16_ 10 x 6 ., • \ 6- / "`� hirygc 12' 45.6 -. 4,. `wtlLaunciry 6x1 y ,7 T. 10x10 18" t2• 10' 18x16 ' MWIC,;' �i 14' 8' 4x8' 9• " 4' 3'Fan /0 x 10 ; dst'. Ret Riseii 1 6x14 16x16 12 I 8- 12' 6x10 • 6 Sup Rise 1 f 12" Fo er ` Great / Dining Kitchen r J 12x12 ik 10x8 12x12 184 !i' 8x14 18• 8. 8x610 6x10 B¢d3t 8x4 6' t 4' Eicct 2 6..12 breakfast Path.Z;.:i area Fan O o In 1 Job #: Scale: 1 : 128 Performed by Stephen Barber for: McGowan's Heating & Air Conditioni... Page 1 Steve Marten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.03 RSU12270 Ponta Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2016-Aug-11 08:24:27 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey@mcgowansac.com ...s\Davenport Bonus 3120 Right.rup www.tollbrothers.com smerten@tollbrothersinc.com 1_ y i►_ Mfr 2nd 3-Fan ath 3 6x10 bed4 5" 14x6 9" 12x1 10' c; �I � 16x 16 14x6 12 s- Ret Riser 12 Sup Riser 12" 12" • loft 14 x 6 s- Job #: McGowan's Heating & Air Conditions... scale: : 128 Performed by Stephen Barber for: Page 2 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.03 RSU12270 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2016-Aug-11 08:24:27 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey@mcgowansac.com ...s\Davenport Bonus 3120 Right.rup www.tollbrothers.corn smerten@tollbrothersinc.com • • McGowan Manual S Compliance Report Job: Date: Neatinc ttAir`' By: P Entire House Stephen Barber CamfiGaunq McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey©mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.3°F Sensible gain: 35788 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.0°F Latent gain: 5550 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 41338 Btuh Indoor RH: 50% Estimated airflow: 1400 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB048+FB4CNP048 Actual airflow: 1400 cfm Sensible capacity: 35741 Btuh 100%of load Latent capacity: 7010 Btuh 126%of load Total capacity: 42751 Btuh 103%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 33.5°F Heat loss: 36330 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB048+FB4CNP048 Actual airflow: 1400 cfm Output capacity: 39594 Btuh 109%of load Capacity balance: 27 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1400 cfm Output capacity: 10.0 kW 94%of load Temp.rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2016-Aug-11 08:23:53 41— wrightsoftt Comfort Builder by Wrightsofl 17.0.03 RSU12270 Page 1 Zeik ...on\Toll Brothers\Davenport Bonus 3120 Right.rup Calc=MJ8 Front Door faces:NE • McGawa res Duct System Summary Dae: °"6"114.4481, Entire HouseCorsWinng By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.262/0.128 in H2O 0.262/0.128 in H2O Lowest friction rate 0.075 in/100ft 0.075 in/100ft Actual air flow 1400 cfm 1400 cfm Total effective length(TEL) 522 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 2 h 916 35 21 0.115 4.0 Ox 0 VIFx 33.7 195.0 st4 • Bed 2 h 4598 177 120 0.112 7.0 Ox 0 I VIFx 38.5 195.0 st4 Bed 3 h 1315: 51 48 0.115 6.0 Ox 0 VIFx 37.2 190.0 st4 Dining h 2196' 85 74 0.075 6.0 Ox 0 VIFx 71.2 280.0 st7 Foyer h 2060 79 57 0.118 6.0 Ox 0 VIFx 32.6 190.0 st4 Great-A h 3507 135 135 0.075 8.0 Ox 0 VIFx 69.5 280.0 st7 Great-B h 3507 135 135 0.075 8.0 Ox 0 VIFx 67.5 280.0 st7 Kitchen c 1933 48 76 0.075 6.0 Ox 0 VIFx 68.0 280.0 st7 Laundry c 827 16 32 0.113 5.0 Ox 0 VIFx 31.8 200.0 st5 M wlc c 18 0 1 0.094 4.0 Ox 0 VIFx 44.0 235.0 st6 M.Bath h 2352 91 59 0.115 6.0 Ox 0 VIFx 27.8 200.0 st5 Master c 2081 77 81 0.098 6.0 Ox 0 VIFx 38.8 230.0 st6 Master-A c 2081 77 81 0.097 6.0 Ox 0 VIFx 41.3 230.0 st6 Toilet c 49 2 2 0.120 4.0 Ox 0 VIFx 27.8 190.0 st5 bath 3 h 1162 45 42 0.111 5.0 Ox 0 VIFx 60.7 175.0 st3 bed 4 c 4050 114 158 0.114 8.0 Ox 0 VIFx 54.3 175.0 st3 loft c 3544 117 139 0.119 8.0 Ox 0 VIFx 46.1 175.0 st3 loft-A c 3544 1171 139 0.116 8.0 Ox 0 VIFx 51.7 175.0 st3 2016-Aug-11 08:23:53 ..: 41- wrightsoft' Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 1 AC' , ...on\Toll Brothers\Davenport Bonus 3120 Right.rup Calc=MJ8 Front Door faces:NE Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 392 478 0.111 608 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 392 478 0.111 608 12.0 0 x 0 VinIFIx st4 Peak AVF 343 246 0.112 628 10.0 0 x 0 VinIFIx st2 st5 Peak AVF 665 676 0.075 632 14.0 0 x 0 VinIFIx st2 st2 Peak AVF 1008 922 0.075 722 16.0 0 x 0 VinlFlx st7 Peak AVF 402 420 0.075 534 12.0 0 x 0 VinlFlx st6 st6 Peak AVF 557 583 0.075 546 14.0 0 x 0 VinIFIx st5 Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rsb4 Ox 0 158 201 171.0 0.075 368 10.0 Ox 0 VIFx rt4 rb4 Ox 0 398 399 133.6 0.096 1143 8.0 Ox 0 VIFx rt2 rb3 Ox 0 177 120 137.1 0.093 401 9.0 Ox 0 VIFx rt2 rb5 Ox 0 234 277 141.9 0.090 508 10.0 Ox 0 VIFx rt4 rb1 Ox 0 432 403 169.6 0.075 404 14.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt4 Peak AVF 392 478 0.075 608 12.0 0 x 0 VinlFlx rt3 rt2 Peak AVF 1008 922 0.075 570 18.0 0 x 0 VinIFIx rt1 rt3 Peak AVF 392 478 0.075 608 12.0 0 x 0 VinIFIx rt1 rt1 Peak AVF 1400 1400 0.075 792 18.0 0 x 0 VinIFIx 2016-Aug-11 08:23:53 .:,_ wrightSOft Comfort Builder by Wrightsoft 17.0.03 RSU12270 Page 2 AC ...onlToll Brothers Bonus 3120 Right.rup Calc=MJ8 Front Door faces:NE 0 IliartIIIP1 BCS 0 BUILDING COMPONENT SUPPLY, INC. O 4627 JP HALL BLVD. SUITE 208 GREEN COVE SPRINGS, FL 32043 1 0: 904.297.9390 F: 904.529. 1 406 BEARING HEIGHTS 91- 1 1 /811 1 01- 1 1 /811 2 01-711 m°'-0° f . 11°6 0 0 THIS IS A TRUSS PLACEMENT OM IMati ,d DIAGRAM ONLY. Ova Tam ', _ . These trusses are designed as individual building components to be incorporated into the building design at the specification of the building I designer. See individual design sheets Y g for each truss design identified on the $ placement drawing.The building } designer is responsible for temporary and permanent bracing of the roof and floor system and for the overall i structure.The design of the truss �,I f—- $ support structure including headers, ,., __ _„_ __ beams,walls,and columns is the I * responsibility of the building designer. i ! E $ For general guidance regarding 1 4 bracing,consult"Bracing of Wood 14 C Trusses"available from the Truss Plate w,.,.„,.,, • Institute,583 D'Onifrio Drive; Madison, WI53179. ATTENTION. - - ,,, ..., Refer to truss layout and engineering $ documents that arrive with delivered "t - field trusses. Unless noted otherwise,all beams are ' by0 thers ,,,_•___... xm.-,_ -- 44r.f..1.1 REVISION DATE nn 1 1 . CHECKED BY 00/00/1 5 a,°, CLIENT TOLL BROTHERS SUBDIVISION ATLANTIC BEACH MODEL DAVENPORT ELEVATION SHINGLE DRAWN BY LOT # CJR DATE SECOND FLOOR LAYC 072 08/24/201 6 REF# SCALE: 3/ 1 611 = 1 1 1 0879T0 4 a Boise Cascade Double 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP Floor Beam1FBM2 Dry 11 span I No cantilevers 10/12 slope August 10,2016 17:08:03 BC CALC®Design Report Build 4516 File Name: 10879T0 Job Name: 10879T0 Description: Designs\FBM2 Address: OFFICE R®PY Specifier: ^ (� City, State,Zip: , C! Designer: 0�J Customer: Company: • \ Code reports: ESR-1040 Misc: (�� Q1 � L N 4 -- 2 T t 1 14-07-02 BO B1 Total Horizontal Product Length=14-07-02 Reaction Summary (Down/Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO, 5-1/2" 3,151 /0 3,544/0 1,469/0 B1, 3-1/2" 3,080/0 3,464/0 1,435/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 Standard Load Unf.Area(Ib/ft^2) L 00-00-00 14-07-02 40 10 01-00-00 2 Wall Unf. Lin. (lb/ft) L 00-00-00 14-07-02 110 n/a 3 F09 Unf. Lin. (lb/ft) L 00-00-00 14-07-02 387 145 n/a 4 T02 Unf. Lin. (lb/ft) L 00-00-00 14-07-02 199 199 n/a Controls Summary Value %Allowable Duration Case Location Pos. Moment 22,128 ft-lbs 59.2% 100% 1 07-04-09 End Shear 5,070 lbs 47.7% 100% 1 01-09-08 Total Load Defl. L/492(0.341") 48.8% n/a 3 07-04-09 Live Load Defl. L/996(0.168") 36.2% n/a 6 07-04-09 Max Defl. 0.341" 34.1% n/a 3 07-04-09 Span/Depth 10.5 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim.(L x W) Value Support Member Material BO Wall/Plate 5-1/2"x 3-1/2" 7,009 lbs 64.4% 48.5% Southern Pine B1 Wall/Plate 3-1/2"x 3-1/2" 6,851 lbs 99% 74.6% Southern Pine Notes Design meets Code minimum (U240)Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design meets arbitrary(1") Maximum total load deflection criteria. Calculations assume Member is Fully Braced. Design based on Dry Service Condition. Deflections less than 1/8"were ignored in the results. Page 1 of 2 ®Boise Cascade Double 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP Floor Beam1FBM2 Dry I 1 span I No cantilevers 10/12 slope August 10,2016 17:08:03 BC CALC®Design Report Build 4516 File Name: 10879T0 Job Name: 10879T0 Description: Designs\FBM2 Address: Specifier: City, State,Zip: , Designer: Customer: Company: Code reports: ESR-1040 Misc: Connection Diagram Disclosure Completeness and accuracy of input must '0-1 b r—d be verified by anyone who would rely on a I ^ output as evidence of suitability for • / ' • particular application.Output here based on building code-accepted design c properties and analysis methods. Installation of Boise Cascade engineered • • � wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum=2" C= 12" (800)232-0788 before installation. b minimum=3" d=24" BC CALC®,BC FRAMER®,AJST"', Member has no side loads. ALLJOIST®,BC RIM BOARDT'",BCI®, Connectors are: 16d Sinker Nails BOISE GLULAMT'",SIMPLE FRAMING SYSTEM®,VERSA-LAM®,VERSA-RIM PLUS®,VERSA-RIM®, VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C.