Loading...
1655 ATLANTIC BEACH DR - NEW HOME PERMIT rI, CITY OF ATLANTIC BEACH , l 800 SEMINOLE ROAD t�` ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 J3',l9r SINGLE FAMILY DWELLING NEW MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 16-SFR-2900 Job Type: SINGLE FAMILY RESIDENCE Description: NEW SINGLE FAMILY RESIDENCE Estimated Value: $367,356.00 Issue Date: 1/19/2017 Expiration Date: 7/18/2017 PROPERTY ADDRESS: Address: 1655 ATLANTIC BEACH DR RE Number: None GENERAL CONTRACTOR INFORMATION: Name: TOLL BROS.,INC , CGC 1510225 Address: 250 GIBRALTAR RD STEVEN R MERTEN Phone: - - PERMIT INFORMATION: FEES: ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $641.03 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $1,282.07 STATE DCA SURCHARGE $19.23 SEWER SDC-SYSTEM DEV $4,050.00 CHG STATE DBPR SURCHARGE $19.23 I'ERMfI IS :U'PRO\Ii) ONLY IN ACCORDANCE WW"I WI ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 4"S, CITY OF ATLANTIC BEACH • s 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 �� INSPECTION PHONE LINE 247-5814 WATER CONNECT/TAP & $370.00 METER WATER CROSS CONNECTION $50.00 WATER SDC-SYSTEM DEV $1,140.00 CHG Total Payments: $7,721.56 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 0L`�3 City of Atlantic Beach 41 �, APPLICATION NUMBER fr `fa Building Department CE'E " 'a� (To be assigned by the Building Department.) If 800 Seminole Road 7 / `SER ` ��O �1 (� 0•.. Atlantic Beach, Florida 32233-5445 JAN 0 3 2017 r 0 Phone(904)247-5826 • Fax(904)247 45 j 01319 E-mail: building-dept@coab.us By, L Date routed: 1 Z/3c /i (G., City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM (� Property Address: 16,Os R ruck )'(-t Q_ r jGptC H Departm,ent review required Yes No (;Buildir _ Applicant: ( l--)Lc `)I. Os ( ADC Inning &Zonin \ l Tree Administrator Project: �i t✓,,J S I kpC-,Le- FRAnt ( L (ubiic Works (ublic Utiliti Public fety Fire Services Review fee __- . - - - _.._. $ �c� Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 11Vpproved. J (Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: it/ Date: i /5- I‘ -7 TREE ADMIN. SReview: ['Approved as revised. ❑ pp ['Denied. IC.W RK Co econd ents: PUBLIC UTILITIES I- 3— 1-7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. Comments: Reviewed by: Date: Revised 05/14/09 I ,�(An33� City of Atlantic Beach °+ ;,aas El APPLICATION NUMBER `�s „t-A-,,,, Building Department ” ' +.�;� (To be assigned by the Building Department.) it 800 Seminole Road 15'1,— �� Atlantic Beach, Florida 32233 5445 ; JAN 0 3 2017 1 Ib --SFR - ��(��� Phone(904)247-5826 • Fax(904)241-6845 -A-..,0110 E-mail: building-dept©coab.us BY: 1 J Date routed: 1 Z/3ci /i City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM r) i? Property Address: ((,ss R 7Lq c .:`((C._ c2,EA�.N DepartiRent review required Yes No ;- (Building—L____ Applicant: ( �--�( 1 l FOS ( !vc lannin_g_&Zonin \ l Tree Administrator Project: Gi,J S I (3 j L� Fq-/Int ( � ublic Works public Utiliti Public Safety Fire Services Review feel. - Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [pproved. ❑Denied.e f foN7 (Circle one.) Comments: fee Atet 4:fJ Gei inc BUILDING 'w/� l� PLANNING &ZONING / Reviewed by: Date://5"--4_, TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. Comments: 1 Reviewed by: Date: I Revised 05/14/09 1 � /kc-c iNetv4c oer:de 4- ,- erho AAti o2d'x .ZJ'a 66 yo M'O° 02679 jaaX /1.3 Y 29 -Iteitikb,ty/44 xrirm �j�od peak, lapcite(e4 C(y � 3 E. 4/1 c);(/-1 pe-r clr:z _ //: I. tz f( /e7ref•tei7 -/ ClAilyz, City of Atlantic Beach ALA. r BuildingDepartment APPLICATION NUMBER �, �a (To be assigned by the Building Department.) E-mail:Seminole Road SFR ` Z�� �r Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 0;;i� Embuilding-dept@coab.us Date routed: 1 Z/30/1L.. City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM i? . Property Address: 1(,55 R r LRb\Y 12)GA0 Ile-parnent review required Yes No Buildin Applicant: ( of u_.. t POS i &1C_ e..ffonin V(tonin \ lTree Administrator Project: Gt-J S i �C- LFF- 11(1( ( L ublic Works / Public Utiliti Public Safety Fire Services Review fee $ Dept Signature • Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: • APPLICATION STATUS Reviewing Department First Review: Approved. ['Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: v'' ate: 75/6 TREE ADMIN. Second Review: A roved as revised. ❑ pp Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 1i �s1.A1.1ry City of Atlantic Beach APPLICATION NUMBER L d � ►A• �a Building Department (To be assigned by the Building Department.) ,�( 800 Seminole Road t / O , Atlantic Beach, Florida 32233-5445 1 l> Phone(904)247-5826 • Fax(904)247-5845 r�r; J E-mail: building-dept@coab.us Date routed: i 130/1 (U City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 C5S TLAK%T(Q. r)6,AC H D patient review required Ye V No . Buildir _____ Applicant: ((J. _ 1-IROS ( !UClanninc,�&Zonin \ 1 Tree Administrator Project: lv GGJ S i {\C-NLC- FiCW‘t ( L ublic WorksD ublic Utiliti Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date • of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. ['Denied. (Circle one. Comments: BUILDING PLANNING &ZONING 4 / 1ctI7 Reviewed by: Date: TREE ADMIN. Second Review: Approved as revised. Denied PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 BUILDING PERMIT APPLICATION OFFICE COPY CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 I l0 —S FR - O 0 Job Address: 1655 Atlantic Beach Drive;Atlantic Beach,FL 32233 Permit Number: Legal Description Lot 10 Atlantic Beach Country Club USngit 1 67-132-08-2S-29E.152 Parcel Floor Valuation of Work$ 367,356 Proposed Workof heat d/cooled 3.163 non-heated/coot led 956 Class of Work(circle one): 42140 Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed?(Circle one): c —N/A 2) Florida Product Approval#See attached For multiple products use product approval form Describe in detail the type of work to be performed:New Residential Construction Property Owner Information: Name:TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904 217-0739 E-Mail or Fax#(Optional)arogers@tollbrothers.com Contractor Information: CONTRACTOR EMAIL ADDRESS: arosrers(n.tollbrothers.com Company Name:Toll Bros.,Inc,Qualifying Agent:Steven IL Merten Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904 217-0739 Job Site/Contact Number 904 386-6472 Fax# State Certification/Registration#CGC 1510225 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months,or ifconstruction or work is suspended or abandonedfor a period of six(6)months at any time .�' after work is commenced 1 understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells,Pools,Furnaces,Boilers, Heaters,Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this op•llcation and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether sped • rein or not. The grantingof a permit does not presume to give authori violate or cancel the provisions of any other federal,state,or local law • 'ng construction or the perormance of construction, Si ature of Owner 411/11P Signature of Contractor v,/ Print Name Steven '. erten Division Sr.Vice President Print Name Steven R. erte Di 'sion Sr.Vice Presiden Before me Before me this 23 a•v• December _2016 this 23 Le. of December ,2016 f .i Notal Pu.l c � '� IA a ) ( No T 4 lic'I /a_ I OU V al s: ASHLEY ANN ROGERS Revised 01.26.10 4 MY COMMISSION#GG019753 ''.?n;.?f EXPIRES August 09,2020 .,Z;•"••' ;; ASHLEY ANN ROGERS a MY COMMISSION#GG019753 ,'w;s!t• EXPIRES August 09,2020 OFFICE COPY • DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions Review Initials/Date: • • Development Size • • Habitable Space 3/6 3 Non-Habitable Impervious area Miscellaneous Information Occupancy Group Type of Construction Number of Stories Zoning District Max. Occupancy Load Fire. Sprinklers Required Flood Zone Conditions/Comments: • i '�' jCITY OF ATLANTIC BEACH ;-) PUBLIC UTILITIES J 1200 Sandpiper Lane ATLANTIC BEACH,FL 32233 401319r (904)270-2535 or(904) 247-5874 NEW WATER/SEWER TAP REQUEST Date: /- 3 -/ 7 Project Address: /6 SC igriA-,QT)[ ay? ,--- No. of Units: / Commercial Residential tZ Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) 3 7 New Irrigation Meter `, Upgrade Existing Meter from to (size) New Reclaim Water Meter Size �C� New Connection to City Sewer 1. Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application#&- S re - 21°6 Water System Development Charge $ f / p, (6 Sewer System Development Charge $ Q j`d, (ft ,/ Water Meter Only $ /e pd 7 Reclaim Meter Only $ /9.5-, (SO r✓ Water Meter Tap $ (notes) Sewer Tap $ Cross Connection $�, 00 V Other $ TOTAL $,5 &,O, vd APPROVED: Kayle Moore,PE (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED OFFICE COPY R.O.W.Permit Attachment of for R.O.W.Permit# issued ,2016 Atlantic Beach,FL 32233 Owner's Name: Toll FL VI,LP Property Address: 1655 Atlantic Beach Drive Atlantic Beach,FL 32233 Subdivision: Atlantic Beach Country Club Lot#/Block#: 10 R.E.#: 169505-1345 REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this day of ,20 ,by Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and Toll FL VI,LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30)days notice by CITY to the USER,said notice to USER shall be given by certified mail,return receipt requested,to the following address: 160 Cape May Ave.Ponte Vedra,FL 32081. The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating,replacing,or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code,Building Codes,Land Development Code,and all other land use and code requirements of the CITY,including City Code Section 19-7 (h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 OFFICE COPY The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall,at the discretion of the CITY,be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of/i liabilities are hereby assumed by the USER. DATED and SIG d'`' this 23 day of December ,2016. By: // Stev e i",Division Sr.Vice President,Toll FL VI,LP. (to , signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this 23rd day of December ,2016,personally appeared before me,a Notary Public in and for said County and State, Duval, Florida , the property owner of 1655 Atlantic Beach Drive, Atlantic Beach,Florida,known to me to be the person(s)described in and who executed the foregoing instrument;who acknowledged to me that he or she executed the same freely and voluntarily and for the use2said urposes therein mentioned. 1 .____A VV UQ _ ' p'�." 'i:;: ASHLEY ANN ROGERS 1 'i MY COMMISSION*GG019753 No County and Stated EXPIRES August 09,2020 I CITY OF ATLANTIC BEACH,FLORIDA,a municipal corporation: Approved: Doug Layton,Public Works Director For Permits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 NOTICE OF COMMENCEMENT State of_FLORIDA Tax Folio No. 169505-1345 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 10 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E.152 Address of property being improved: 1655 ATLANTIC BEACH DRIVE,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner.TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD. HORSHAM,PA 19044 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor: TOLL BROS..INC. Address:160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN,Division Sr.Vice President Address:160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: 11 Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: Date: /2/23 ,_ �G Before me s r day of in the ounty o— Jo t A Vim' A State Of F• da,has personally appeared PO' 1—Y I Notary Public at Large,State of Florida,Coun ofJ 2,0 2, JOHN II My commission expires: /- 10 I' Personally Known: y or Produced Identification: I h, r v/1 I J Fl. �,.",`,:v. : ASHLEY ANN ROGERS N:4 1 :* MY COMMISSION#GG019753 '".?aN ` EXPIRES August 09,2020 111 Doc#2016295251,OR BK 17825 Page 515, Number Pages:1 I Recorded 12/28/2016 at 02:48 PM, II Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING$10.00 0 R.O.W.Permit Attachment of R.O.W.Permit# issued 2016for Atlantic Beach,FL 32233 Owner's Name: Toll FL VI,LP Property Address: 1655 Atlantic Beach Drive Atlantic Beach,FL 32233 Subdivision: Atlantic Beach Country Club Lot#/Block#: 10 RE.#: 169505-1345 REVOCABLE ENCROACHIVIENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this day of 20 ,by Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and Toll FL VI,LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained, repaired,erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30)days notice by CITY to the USER,said notice to USER shall be given by certified mail,return receipt requested,to the following address: 160 Cape May Ave.Ponte Vedra,FL 32081. The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating,replacing,or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code,Building Codes,Land Development Code,and all other land use and code requirements of the CITY,including City Code Section 19-7 (h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials,but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall,at the discretion of the CITY,be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of . Iiabilities are hereby assumed by the USER. DATED and SIG ',,of this 23 day of December ,2016. By: /1' Stev• elm,Division Sr.Vice President,Toll FL VI,LP. (to signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this 23rd day of December ,2016,personally appeared before me,a Notary Public in and for said County and State, Duval, Florida , the property owner of 1655 Atlantic Beach Drive, Atlantic Beach, Florida,known to me to be the person(s)described in and who executed the foregoing instrument;who acknowledged to me that he or she executed the same freely and voluntarily and for the uses urposes therein mentioned. `LPusaidCountyande VV vaii '"4, ASHLEY ANN ROGERS m •'i MY COMMISSION#GG019753 for EXPIRES August 09,2020 CITY OF ATLANTIC BEACH,FLORIDA,a I municipal corporation: Approved: Aos, ; is Wor ,Director '• soba..,' For Permits where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 N �D Oo -1 QN V. & W N — SIJ O� Cly A W N ›.• 3-cc>n c o x o o _ a• m rt n -B N• -° -, u, CD a n p• a Q B ri) NO c• 1) 't -o = U l74 -j . a. 0 CD tD O 00 p O.. -,, UQ C _ p fA p tt p -i p • 0- n. �' c� a G (4 p 7c 4 a- To UQ �� C O 1G ^r1 fl' AZi a a. • d O -, (D CD d ( n v co a O o iv B °' nC A < o V) -- H O °N' Z p ••..< G VI �' � C &-.).• �, y a' •o < a. LA o 77 cr ° .- O C T o -o 'v -o n ~o V) a o a. 003:.3 6 6 C7 o 0 0 a) © —3 " - ) o o b 3 t `ti o a te. Y Y O ° -a o �' a. A) n _ O �- r� -, r. 6' t-, 2' n v. .� C Q' .� �. r1• ,--i co 0- -o O q W .t -. m 0) `s7 a. < 0 �' r O o 0 () 'r1 3 o n. r Y • B rc X J ,CD crc .0 o 0 �' Z 0..., CA to Pa `<• co N trl < r� 0 m 0 -o o o E. `0D o 00n C \ o 00 �. < • - o �' o ` c Cf -n. 0. a —: Ho a ° Q. C) ° o o d ^. .-. TS 5. N < < vo`io CD 0 o ► vi o 7 '6 g O ro a p 5. `t ) • ° 3 1-3 •• CD a• it Y O '- ! LA LA Ll) N N ti Z Z -- '0 •-• 0 -ti o 0 0 0 0 > r o a � 9 g a. n -T1 w �, V, �, 7. a w 0 © 0 0 CO o v I �7 ( B. o o -n o .. cD o n 0 UQw x 0 0 a q1 cro a' cr I O r r — r r r r r r r off , v e N V, .-- -- U. .) V, — o0 0 E. 1J 00 O OT O 00 4- IJ V, t 4- N C O '� V, O — J-- w — G, O tJ L V, IJ 00 ..n , tJ a. W J r .�' co 5 co 0 `ri tJ co LAN 01 0 Mn r l 0 A 0 4k rn n 0 -v a •••-.1 °O Cs Vi A W N -- O 00 J ON IA W -- 7 �n V Oo --I ON Vi 4A• W N -- C7 no cnWi: 5UUH 7C D 7:) O in 0 C) n cn m cn n .b 70 o 7 es c o 77 ° cow o v in iu '" oa ua uc rs CD vas � N o n r o gip' a c. N q 7 c cn °O C °""'i A� 7 �_ tl0 "0 E N • -• y v? N ocoN F. I a 0 r Cr1I5 -• (ta 7CD o ° r n °on-n uci Moen r. z � z = ° o > 3 • 3 20 o -1 < 3 a 7- CD r. n ¢ 7 CD w J ° G. 't7C7 O p. 0 D.. l go i1 N '.D N "6 (D a. C � U7 p A� N - v -• a a. ,- -] n a' PS C 0 uo na c n c -, 0 0 a i:,--.- U: ^. f, n o °o 7, �' -n '0 t3 r o m -o cr -3 : cn cn 7 �, C a' -v '-o a: E. Oa .� 7 7 n A� P� oa. 5* o G a PS 0 0 u U a (fa ., W (n N N WAl (D f00 <i O Q. 7 " szoV) O rt, ,� PPS 7- 7- 0 v 0 n. w V1 m >(1 U_ 7g a7- y cco co � b a s r, a' s is: 0. r, 0 J. 7 7 Z z � Z o � yz 7 y y D Y > -• L! o 9 0 7 0 C tit Co r r r r r rr r r r PJ W N J=am Co O O N W v, N W 3-- J - W - O O N • O .- -. IJ -. ' . .- W N En NW A co N [ ' 00 N 0 V 0 a 1 Pa 4t s'• n 5 tJ — tri x tJ -- n - iJ O V' 00 -1 O\ (n .P W N - n )71 -.1 O\ VIW N :•-• r=7 • = w ZZ• H �, � 'bIIEi1FH OA• a. Q 3. < 0 - : ncp o ►-3 0 _ ci -6 P r� 9 N C. CD .5 V1 III CT d C-3 cn aCD Pa a L- o cn C) Y v) o - 6 — a o 9 c Y —. CT, II ^_ N (IQ CD o y -a CD O —. ^vCI co a n < tl. < O O 7 Aj w W -• CD = r 1 ? �, C/ a -. ,< C CD o' r CD - n G CD ry O - ^1 CCD N -1 CD -i O N. 0 O V) LA O CO •a 0 CD .--r i n a. o o cp -n o 0 W >v a C °' `< 0.0 oa n a P ^1-7 Cr, ^I ✓? -O C v, Oflb W n go i . r, v O D r: -0 .vim a n � CD CD -I 0 cr 9 g 6 . ni • P `-< "7 C -h C C O 6 - o -o. t J C ti rn n O.1_ 0 (JQ to -t S. n ::1. 'F'D C) (CSD a a. O t r i cn Q O 0 n a P. 0 V) N 0 N a n • Q 0 O' O ~' a a C rD • �. .S..t ..9 `D -1 • 0 _..-t- (-0 iJ IJ O N _. — fes') O LU I J • 'C, -.' 7 CD Co) (n cD CD r CD ct O D p, C -^• -1 CD f1O ODD3C 0 �.n ,1 O - Or M A n 4t 0 co CD 'e 0) 9 0 a s co 0. `� p 5. 0' z z •d a z " y y cD CAD CDA"0 bD (^ a o D O o - w CO '3 rn b p 'v o co y Z 0 0 AI pa N 1-04'0 n co b co N co • 0 0.cr ^_^�� G CD CD = Q. Ua G A O F1 N 6 0 00 A CD (D • y 0 M 5 n- 0 X i) 070 92. z P. CL Cr C n '1 c CA r co N `1 A CD y N ^ 5. o v' —. ?; ro n t C o W to co O 5 C1 Er 1 :y •.h W N S N Cop ro cc nib A A O C- 0 3 .n ► 0 lb CD CD 0 0 C 0 C'" coS 5. Qco 0 "11 co m y C) M n 0 13 OFFICE COPY FORM R405-2014 _ FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cumberland 3163 Left Builder Name: Toll Brothers Street: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner. Toll Brothers Jurisdiction: 261300 i Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4448.2 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 4266.70 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 181.50 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (2005.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1793.00 ft2 6. Conditioned floor area above grade(ft2) 3163 b.Under Attic(Vented) R=19.0 212.00 ft2 R= Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(331.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 425 I a. U-Factor: Dbl,U=0.33 331.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 42.0 SEER:14.00 SHGC: . c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency • d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 3.672 ft. - Area Weighted Average SHGC: 0.300 14.Hot water systems a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (3163.0 sqft.) Insulation Area EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2005.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1158.00 ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 67.69 Glass/Floor Area: 0.105 PASS Total Baseline Loads: 84.42 I hereby certify that the plans and specifications covered by Review of the plans and •••A"Ck1E STAT.,,.. this calculation are in compliance with the Florida Energy specifications covered by this '°�w.- t:*__, ;'';,:0 4.. Code. calculation indicates compliance r,,.:/rig r ,o 0-,.• e ' • / with the Florida Energy Code. r F.im,,,.'., ::` ,; �•;O = PREPARED Y: �.ffe�ficyr�( ✓�✓e Before construction is completed ` .a'• " ,- a _'.'. DATE: 12fis �G this building will be inspected for i t7 .:-` compliance with Section 553.908 ', *`• Qe' ! 4 c-. I hereby certify that this building,as designed,is in compliance Florida Statutes. ':,•T+. �' with the Florida Energy Cod-. `+ OWNER/AGENT' Ad i BUILDING OFFICIAL: 1 l^ �� DATE: 12-I 29, I , DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed In accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. i I 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 r FORM R405-2014 PROJECT Title: Cumberland 3163 Left Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 3163 Lot# Owner: Toll Brothers Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: . Builder Name: Toll Brothers Rotate Angle: 0 Street: 1655 Atlantic Beach Dr. Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range VJ FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 3163 30472 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated . 1 Main 2005 20050 Yes 3 2 1 Yes Yes Yes 2 2nd Floor 1158 10422 No 3 3 1 Yes Yes Yes FLOORS ✓ # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet V 1 Slab-On-Grade Edge Insulatlo Main 212.9 ft 0 2005 ft' ____ 0 0 1 ✓ 2 Floor Over Other Space 2nd Floor ____ ___ 1158 ft' 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) V 1 Gable or Shed Composition shingles 2322 ft' 586 ft' Medium 0.4 N 0.9 No 0 30.3 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2005 ft' N N • 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 I FORM R405-2014 CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type V_ 1 Under Attic(Vented) 2nd Floor 19 Blown 212 ft' 0.11 Wood V 2 Under Attic(Vented) 2nd Floor 38 Blown 946 ft2 0.11 Wood V/ 3 Under Attic(Vented) Main 38 Blown 847 ft' 0.11 Wood WALLS / Ad acent S ace Cavity Width Height Sheathing Framing Solar Below V # Ornt Tp Wall Type p P I Iiie Ft In Ft In Aran R-Vapin Fractinn AhhOr Gracie° ✓ 1 W Exterior Frame-Wood Main 19 19 10 10 0 198.3 ft2 0 0.23 0.5 0 ✓ 2 S Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft' 0 0.23 0.5 0 f V 3 E Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.5 0 V 4 N Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 0.23 0.5 0 ✓ 5 W Garage Frame-Wood Main 13 20 2 9 0 181.5 ft2 0 0.23 0.5 0 V 6 W Exterior Frame-Wood 2nd Floor 19 19 10 10 0 198.3 ft2 0 0.23 0.5 0 Y 7 S Exterior Frame-Wood 2nd Floor 19 76 9 10 0 767.5 ft2 0 0.23 0.5 0 V. 8 E Exterior Frame-Wood 2nd Floor 19 40 0 10 0 400.0 ft2 0 0.23 0.5 0 V 9 N Exterior Frame-Wood 2nd Floor 19 76 9 10 0 767.5 ft2 0 0.23 0.5 0 1 • DOORS # Ornt Door Type Space Storms U-Value FtWidth In FHeightln Area V 1 W Insulated Main None .6 3 8 24 ft' __V____ 2 W Insulated Main None .6 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening '1 1 W 1 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 6 ft 4 in 1 ft 0 in None Interior 5 • 2 S 2 Vinyl Low-E Double Yes 0.33 0.3 75.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5 V 3 E 3 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 V 4 E 3 Vinyl Low-E Double Yes 0.33 0.3 72.0 ft' 10 ft 0 in 1 ft 0 in Drapes/blinds Interior 5 I 5 N 4 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft' 1 ft 4 In 1 ft 0 in Drapes/blinds Interior 5 • 6 N 4 Vinyl Low-E Double Yes 0.33 0.3 4.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 ✓ 7 E 8 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Interior 5 ✓ 8 S 7 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft' 1 ft 4 in 1 ft 0 In Drapes/blinds Interior 5 V 9 N 9 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft2 1 ft 4 in 1 ft 0 In Drapes/blinds Interior 5 GARAGE ✓ # Floor Area Ceiling Area . Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation V 1 659 ft' 540 ft2 64 ft 9 ft 1 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 I1 ' FORM R405-2014 INFILTRATION ACH 50 SLA CFM 50 ELA EqLA ACH # Scope Method 1 Wholehouse Proposed ACH(50) .000306 2539.3 139.41 262.17 .2901 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 y/ 1 Electric Heat Pump Spilt HSPF:8.2 42 kBtu/hr 1 sys#1 i COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts f 1 Central Unit Split SEER:14 42 kBtu/hr 1260 cfm 0.7 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation • _i_ 1 Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg None I i SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF VNone None ft2 DUCTS / --Supply-- --Return— Air CFM 25 CFM25 HVAC# vJ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 �/ 1 Attic 6 425 ft2 Attic 106.25 Default Leakage 2nd Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[[XX Jan [X1 Feb X]])Mar [[ j]Ar [ ]Ma [Xuunn ]Jul IN Augu 1XSee [ ]Oct [X]NNoovv, X Dec Venting [ Jan [ Feb X]]Mar [Xl Apr [ )May E ]Jun ( )Jul E ]Aug )Sep [X]Oct [X] Nov t 1 Dec • 1 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 78 0 78 80 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 7 78 78 8 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 688 66 Heating(WEH) AM 66 68 66 66 66 68 68 68 68 68 68 66 MECHANICAL VENTILATION . Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1-Electric Heat Pump 0% 1 -Central Unit i I . ;t 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 i FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. 1655 Atlantic Beach Dr. (Lot 10 AB) , Atlantic Beach , FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 4266.70 ft' b.Frame-Wood,Adjacent R=13.0 181.50 ft2 3. Number of units,If multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) . R=38.0 1793.00 ft2 6. Conditioned floor area(ft') 3163 b.Under Attic(Vented) R=19.0 212.00 ft2 c.N/A R= ft2 7. Windows*" Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.33 331.00 ft' a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 425 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.672 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems : a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2005.00 ftEF:0.8 b.Floor Over Other Space R=0.0 1158.00 ft' b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ,o,.113E ST,q::.''.b. Construction through the above energy saving features which will be installed(or exceeded) , ,, p in this home before final inspection. Otherwise, a new EPL Display Card will be completed :` "� °'��' `< °_ ' '0�++' p Y p �i err :;•°•��;��� '�' based on installed Code complia -atures. '"'tip ';: ,':,;t ,;` °'�. :.�_ . =�-:^ter ` � I lo -..'ii,_ -_ . 171 Builder Signature: Date: 2 2$ I ((p a 1 . ' JS t� 11Ci /FL Zip: 4 ...0,44:,� Address of New Home: D Q� L ( Or. City/FL AB �� :1'. ..,#, 32�3 3 coD .. ,. *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Number: Atlantic Beach ,FL, MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be Included as an addendum to each sales contract for both presold and nonpresoid residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. •• ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in • accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per-hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/l.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)Ali ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler Is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not In use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have • heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls o R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy } factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water • heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. ( 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 1 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is Installed In an unconditioned space. Exceptions: 1. Attached single=and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.5.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected In Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system Is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSIIAPSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested In accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested In accordance • with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently Installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently Installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights I ❑ R405.2 Performance ONLY. All ducts not entirely Inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum Insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 12/15/2016 4:08 PM EnergyGauger USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cumberland 3163 Left Builder Name: Toll Brothers Street: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number: . Owner: Toll Brothers Jurisdiction: 261300 • Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable Insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in ------- J substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. \_► Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. \.,J Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. \ Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be yJ air tight, IC rated,and sealed to the drywall. ` Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in V exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have Basketed doors 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 F FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Cumberland 3163 Left Builder Name: Toll Brothers Street: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach ,FL, Permit Number. Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 3163 sq.ft. Cond.Volume: 30472 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data I I HOUSE PRESSURE I FLOW: I ELA: EqLA: ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, *�0.4 11XE.SrAT80'' performance results demonstrate compliance testing shall be conducted by an y� n # ,� ,fit• .•,' . , . with Florida Energy Code requirements in approved third party.A written r �s Le:, accordance with Section R402.4.1.2. report of the results of the test shall f-• tstrie-to6 ;�. ..: : be signed by the third party � conducting the test and provided to g n SIGNATURE: the code official. * z �4 ��,.., ,Y' -", OD wE't ,n•� PRINTED NAME: "••' BUILDING OFFICIAL: DATE: DATE: • 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 McGowan, Project Summary Job: Lot 10ABCC Date: I/ t4'IrJ.kr pN ii cwraur Entire House By: Stephen Barber McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Notes: Cumberland Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 grub • Heating Summary Sensible Cooling Equipment Load Sizing Structure 31869 Btuh Structure 24629 Btuh Ducts 4398 Btuh Ducts 5559 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36267 Btuh Use manufacturer's data Y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29588 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 4275 Btuh Fireplaces 0 Structure Ducts 975 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(PZ) 3163 3163 Equipment latent load 5850 Btuh Volume(fN) 29777 29777 Air changes/hour 0.28 0.15 Equipment total load 35438 Btuh Equiv.AVF(cfm) 139 74 Req.total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btu h@47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.034 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=30°F Backup: Input=9 kW, Output=31117 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th,�_ Ed. .,{.� 2016-Dec-15 15:31:50 I" wf ightsoft" Comfort Builder by Wrightson 17.0.16 RSU12270 Page 1 'CCP'. ...truction‘Toll Brothers\Cumberland 3163 Left.rup Calc=MJ8 Front Door faces: W • *.4e N 410p• First Floor m.wic 4x8 q 4" m wic 2 master bed I 4x8 : 14x6 4" 14x14 8" V., 12" 8x4 :4+ 4" 4„ 67' 12 x rn,bath 3"Fan am 3"Fan ■ J 10" 12 x 12 3"Fan family MIR 8 �sath2 6x10 8x4 bed 2 6" 4" Sup Riser 6 x 12 7" 12" hall 14x14 12 12" stairs 10x10 10 x 1 ^ kitchen 6 x 10 laund, 5" 10 x 6 6" .n 0 o .., 8 x 4 4" pan. garage foyer 12x12 14x6 12x12 10" 8" living rm 10x6 6" Job #: Lot 10 ABCCScale: 1 : 101 McGowan's Heating & Air Conditioning, Performed by Stephen Barber for: Page 1 roil Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 17.0.16 RSU12270 Phone:904-278-0339 Fax:904-278-0366 2016-Dec-15 15:33:12 www.mcgowansac.com korey©mcgowansac.com ...rothers\Cumberland 3163 Left.rup N `L /114\ Second Floor bonus rm 12x6 12x6 12x12 7" 0,1 8x4 owder 4 8x4 4" 10" Ilallway Storage.; 10" 14" 16x16 14" Sup Riser ■■ a ■ Fri c" LL�7�77_IIISS��� 6x10; 10" 5" Oak ■ 12x12 lral J .114 8" 12x12 14x6 Hwy2 10° a" 10 x 6 Bedroom 4 Bedroom 3 6" i 4x8 8x4 4" 4" Bath 3; Bath 4, Job#: Lot 10 ABCCMcGowan's Heating &Air Conditioning, Scale: 1 : 101 Performed by Stephen Barber for: Page 2 Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft Orange Park,Fl 32073 17.0.16 RSU12270 Fl Phone:904-278-0339 Fax:904-278-0366 2016-Dec-15 15:33:12 www.mcgowansac.com korey@mcgowansac.com ...rothers\Cumberland 3163 Left.rup Manual S Compliance Report Job: Lot 10ABCC �iC(;r>dW$il'�t p p Date: =a***fl Entire House By: Stephen Barber �' McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Ft 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 29588 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 5850 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 35438 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 29516 Btuh 100%of load Latent capacity: 6817 Btuh 117%of load Total capacity: 36333 Btuh 103%of load SHR: 81% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 36267 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Output capacity: 32380 Btuh 89%of load Capacity balance: 30 °F Supplemental heat required: 3887 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 9.1 kW 86%of load Temp.rise: 30 °F Meets are all requirements of ACCA Manual S. 2018-Dec-15 15:31:50 wrightsoft° Comfort Builder by Wrightsoft 17.0.18 RSU12270 Page 1 I€K ...truction\Toll Brothers\Cumberland 3163 Left.rup Calc=MJ8 Front Door faces: W Duct S stem SummaryJob: Lot 10 ABCC McGO�'an � Y Date: yiaHtrnB/Ur , Entire House By: Stephen Barber ccxufit6nrlfng 4 McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.243/0.147 in H2O 0.243/0.147 in H2O Lowest friction rate 0.091 in/100ft 0.091 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length(TEL) 430 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat! Ln(ft) Ln(ft) Trunk Bath 3 h 365 12 11 0.122 4.0 Ox 0 VIFx 19.3 180.0 st6 Bath 4 h 345 12 10 0.122 4.0 Ox 0 VIFx 19.5 180.0 st6 Bedroom 3 h 2613 88 84 0.119 6.0 Ox 0 VIFx 23.7 180.0 st6 Bedroom 4 c 3060 124 124 0.119 8.0 Ox 0 VIFx 23.5 180.0 st6 Oak Stairs:A h 589 20 18 0.124 5.0 Ox 0 VIFx 15.5 180.0 st6 Powder h 279 9 7 0.114 4.0 Ox 0 VIFx 22.6 190.0 st7 Storage:A h 1276 43 34 0.116 4.0 Ox 0 VIFx 20.1 190.0 st7 bath 2 c 36 1 1 0.119 4.0 Ox 0 VIFx 14.5 190.0 st4 bed 2 h 2202 74 59 0.124 6.0 Ox 0 VIFx 11.5 185.0 st4 bonus rm-A c 3104 80 126 0.110 7.0 Ox 0 VIFx 25.0 195.0 st7 bonus rm-B c 3104 80 126 0.110 7.0 Ox 0 VIFx 30.1 190.0 st7 family h 2789 94 89 0.112 7.0 Ox 0 VIFx 26.0 190.0 st4 family-A h 2789 94 89 0.091 7.0 Ox 0 VIFx 37.4 230.0 st5 foyer h 2435 82 76 0.102 6.0 Ox 0 VIFx 44.1 195.0 st3 kitchen c 1732 32 70 0.107 6.0 Ox 0 VIFx 36.5 190.0 st3 laund. c 1041 25 42 0.105 5.0 Ox 0 VIFx 36.0 195.0 st3 living rm h 3951 133 127 0.104 8.0 Ox 0 VIFx 43.5 190.0 st3 m.bath h 704 24 13 0.097 4.0 Ox 0 VIFx 26.0 225.0 st5 m.wic h 1154 39 16 0.091 4.0 Ox 0 VIFx 37.7 230.0 st5 m.wic 2 h 1015 34 17 0.093 4.0 Ox 0 VIFx 30.6 230.0 st5 master bed h 2967 100 74 0.093 8.0 Ox 0 VIFx 31.0 230.0 st5 pan. h 697 24 9 0.105 4.0 Ox 0 VIFx 42.0 190.0 st3 we c 12 0 0 0.096 4.0 Ox 0 VIFx 27.5 225.0 st5 2016-Dec-15 15:31:50 +I" wrightsoft Comfort Builder by Wrightsoft 17.0.16 RSU12270 Page 1 ...truction\Toll Brothers\Cumberland 3163 Left.rup Calc=MJ8 Front Door faces: W Supply Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 296 325 0.102 414 12.0 0 x 0 VinIFIx st1 st5 Peak AVF 291 209 0.091 534 10.0 0 x 0 VinIFIx st4 st4 Peak AVF 461 359 0.091 587 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 757 684 0.091 708 14.0 0 x 0 VinIFIx st2 Peak AVF 468 541 0.110 506 14.0 0 x 0 VinIFIx st6 Peak AVF 256 248 0.119 469 10.0 0 x 0 VinIFIx st2 st7 Peak AVF 212 294 0.110 538 10.0 0 x 0 VinIFIx st2 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb8 Ox 0 229 214 133.7 0.110 420 10.0 Ox 0 VIFx rt1 rb9 Ox 0 183 231 155.9 0.094 216 14.0 Ox 0 VIFx rt2 rb11 Ox 0 438 433 153.0 0.096 1254 8.0 Ox 0 VIFx rt2 rb10 Ox 0 375 347 162.5 0.091 687 10.0 Ox 0 VIFx rt2 Return Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 1225 1225 0.091 877 16.0 0 x 0 VinIFIx rt2 Peak AVF 996 1011 0.091 945 14.0 0 x 0 VinlFlx rt1 2016-Dec-15 15:31:50 .;;, "'I r wrightsoft Comfort Builder by Wrightsoft 17.0.16 RSU12270 Page 2 AM ...truction\Toll Brothers\Cumberland 3163 Left.rup Calc=MJ8 Front Door faces: W i McCowan Static Pressure and Friction Rate Job: Lot 10 ABCCDate: tiruarina,Air By: Stephen Barber Candi inftM? ; Entire House McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses 0.06 0.0E Coil 0 0 Heat exchanger 0.00 Supply diffusers 0.02 2 Return grilles 0.03 0.02 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.39 0.39 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 15 17 Measured length of trunk 23 6 Equivalent length of fittings 230 140 Total length 268 163 Total effective length 430 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.091 OK 0.091 OK Return Ducts 0.091 OK 0.091 OK Fitting Equivalent Length Details Supply 11C=40,4AD=60, 11G=5, 11C=40, 11C=40, 11G=5, 11G=5, 1A=35:TotalEL=230 Return 6L=20, 11C=40, 11G=5, 11C=40,5E2=35:TotalEL=140 2016-Dec-15 15:31:50 . wrightsoft' Comfort Builder by Wrightsoft 17.0.16 RSU12270 Page 1 lak ...traction\Toll Brothers\Cumberland 3163 Left.rup Calc=MJ8 Front Door faces: W NOTICE OF COMMENCEMENT JOB COPY State of_FLORIDA Tax Folio No. 169505-1345 THIS PLAN MUST BE County of: DUVAL To Whom It May Concern: ON JOB SITE FOR The undersigned hereby informs you that improvements will be made to certain real property,and i t accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. ® H INSPECTION Legal Description of property being improved: Lot 10 Atlantic Beach Country Club Unit 2.67-131 0 S- �1• Address of property being improved: 1655 ATLANTIC BEACH DRIVE.ATLANTIC BEACH.FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner.TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD. HORSHAM,PA 19044 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor. TOLL BROS..INC. Address:160 CAPE MAY AVE.PONTE VEDRA.FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN.Division Sr.Vice President Address:160 CAPE MAY AVE_PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: Date: /2/4//G Before me day of in the ounty o t lou,b u VC State Of F• da,has personally appeared (�' r Notary Public at Large,State of Florida,CountyofT .JOHN My commission expires: 2.0 2 Personally Known: V/ or Produced Identification: I• -Dt 1 vQ I J F ASHLEY ANN ROGERS MY COMMISSION#GG019753 '•;+aw ' EXPIRES August 09,2020 Doc#2016295251.OR BK 17825 Page 515• Number e :1 RecordedPag12/28/2016 at 02:48 PM, Ronnie FussellsCLERKa CIRCUIT COURT DUVAL COUNTY RECORDING$10.00 oo J a\ w p w N CO ON v, p w N '-< O y O G v, � - nn 7 a '-0 y ^I p n Z v' o _ rii Po cD o 3E � ° ° vmoCD . _ ao . C c . Z ( o - a o cr • °• • s a N ' o � oa , a co o ° r c c C p �� caz to c cta Z CD o -, SI) - Cr O ~ w 1 v, (o 0 O o c C.) O .. = °� ti ( w o Z o '< c o v, N <• a cs v, "� a O in' W ^ O • T -0 -0 `0 ^0 n -0 ? v.) D' O - (7• n v' ▪ H H H H -aa -� ...1 -�a n °• ry 00 0 ` C 0 O Q. • S • n O O O CO 0 ) _^ ( Od b D UG na < a 0> O O CD _ 2 - • a a aa- n. -0 P o 0 0- B a r., �� en a, aa . CA - E. O6 w "Il E. C) O G O c n 'r1 4 o a. CI. w Y N )"3 CD 0 X N O W "--,) O `' 2 W 'N-. CU x << J n-* lJ ril F '<' C a a s r> Ooo o O 'O co ` ' - O Po N O • o 3 oca. s. 0- 0. o o n PZ O 0 � rcl Ca. • N UG D. N O J , 0 0. .) -. x o na o o 0 r d IDa o0, < a < v, o = a. O y a. P, a n 3 m C, � b z _i + + Nz -. r - (/, 0 - y 0 0 a o y0 wo 0 G, C� 0 00 0 � v P tz .. • o O v ril -nn 0= „co o C) 1 g z sc ti... ....1 1 r. -7, �, -n .t., -1 -r1 Ind . i c.. 4 r r r r r r r r o 0 11, ` d — — tJ ,� IJ V, .-. (50 �J 00 O ON 0 00 A V, V, IJ T. (D J CO _ .. y W — c� (c W' 5.?..°V, 0- 0 lJ 4-- v, N 0O .r1 ,�.� t-ri- 0 Go �.. m h r ® , � c n r 1 J O to ? W N — O poo J Q\ N A W N — 0 ,- O O oo J O. to ? W N — n + —, to 74 7d (n 00 Z 7d C D c4 0 K 0 n N m o Nj O• 1a 0 CD CD r; C o o 2 o c o o a N O << c CD F m c o -n y 2 • so -• a m oa w t3 (fa ao v n v da N =� », o w o °c a u4 Pct r3 o io v o ti go cn co w n �• 0 = c °fluj o a a y.� N 1a H, Q. N (/Q I N N y n v)O y CD o r n d c m 0 CD P CA fQrt) 0 o y s 3 O rCD .. = 3: u, T tn =• O0 ^ " -ryt x x p oa.. -o C) 00. 0 0. = E 73 CD -3 F ,a Q CO co N r 5 s.) » -. O N N• 5' G a. -n r; CD o 0� GC ,n-. CD fl.. R. C ✓ 0 o o I r 0 CD -� o o w 31) T4. Al -' 'S co -. .+ (n (n 7. CD sp" ^b 71 R. Q. Ca. � O 0 1,_ - - w vv) w v, a p "'C7 ,o O 0.. O. p -- _z-_ - • • i (n r t,a (,o F% Cu T. S 'V v) co (/) Cj n S a -t 7 co '0 (0 N - 0 I ( = N Z. z Z zzz W zzz z o > 5 a > r Y > YYY �. o' a 0 - ',4.4.d - --n C -n -n -n -n -n -n ® -n -( -n — -n -n r r r rrr- r rr err ,,,, J W 1J J-. COO O N W tJ Ij, N W 0 — .J --- ,— -- O 0 N • 0 V.. �. tJ — l' �.?0 r \ _ t — w iJ �.do — CD cA r N _� rn 0 .o .o ,' d 0 W. 00 t.) r- 0 O n I It N —. = J c...) W — — .0 00 J CN VI A W N r 7i -] 0 u., J, l..! N , c - a. C Z CL r21 t21 x w •C7 0 o aI4ib 0 = 0(IQ "C a ^c wy ' ° B - -0 a -1 IQ cD N» `~ o = wz D mi ,. 0 0 CD fa. CD co PO Cs7 N wz cn CAO b W O lit C7 O (D a - w 7� y o cooUo a - v) o 9 o a 0 c < c o .D3 `< D v, = _ H . (D cn co Fa o C7 N T. b7 a 0. p < a 0 0 0 (D "•'i cD Ao n r a n . 6" n a' 0 N 'CS s O V) CL N G al ' t n i]. O O cD "' A 0 CM o. w n Q ^r -o 1./ (jq N -t O O co n C 0- n w X o n a 6 -- cr cop i UQ CD CD a.co r- Q a. O nN N '^n N 0 A (1' O ' a M 0 0 N w E. (D a a. -n • "'1 r- • CD CD O' (J tJ 0 00 — w 4- (.> uQ !lc) P) J •w 0' 0' CPN w (n — CD CD O• O- 0, .rD- W O Ct (0 (J(QQ r- O 0 Yl. i 0 0 n - c'T `` = 3 c. a = E o '� , o O vo w v. • , ' z Z o ca. w Z N CA = o O• Cr N V: co g N n to CD CDn r! < C C t, OQp ^ n W N (� elj C A� o (D.ca y z CD o N .0 n : W o = fD N. c a. CD cr eD cD o CO a' n . o cto O ° CDF) 0 0 M g 0 tri 'n :n CD X E. z C a.a. C - cn .. n N � �o C1 p co co Illk co o -11 _ a w o n rao o aFP ® X _C w -7x E:y3 al . .. Z 0 Pa kir Mem Z :--) ra a CD ®BolseCascade Double 1-3/4" x 16's VERSA-LAM® 2.0 3100 SP Floor Beam1FB01 111 Dry I 1 span I No cantilevers 10/12 slope November 10, 2016 07:42:04 BC CALC®Design Report . Build 5613 File Name: FB02 Job Name: Description: Designs\FB01 Address: Specifier: City, State,Zip: , Designer: Customer: Company: Code reports: ESR-1040 Misc: 1 + 1 . 1 : 1111111111114 * 1 1 1 1 $ l ttt t t , , , 1 it 18-00-00 BO B1 Total Horizontal Product Length=18-00-00 Reaction Summary(Down/ Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO, 5-12" 732/0 2,926/0 1,463/0 B1 708/0 2,833/0 1,417/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 Standard Load Unf. Area(Ib/ft^2) L 00-00-00 18-00-00 40 10 02-00-00 2 WALL ABOVE Unf. Lin. (lb/ft) L 00-00-00 18-00-00 0 124 n/a 3 T38's ABOVE Unf. Lin. (lb/ft) L 00-00-00 18-00-00 160 160 n/a Controls Summary Value %Allowable Duration Case Location Pos. Moment 19,139 ft-lbs 41% 125% 3 09-01-12 End Shear 2,941 lbs 27.6% 100% 1 01-09-08 Total Load Defl. 0476(0.442") 50.5% n/a 3 09-01-12 Live Load Defl. U1,321 (0.159") 27.3% n/a 6 09-01-12 Max Defl. 0.442" 44.2% n/a 3 09-01-12 rA Span/Depth 13.1 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim.(L x W) Value Support Member Material BO Wall/Plate 5-1/2"x 3-1/2" 4,573 lbs n/a 31.7% Unspecified B1 Hanger 2"x 3-12" 4,427 lbs n/a 84.3% Hanger Notes Design meets Code minimum (U240)Total load deflection criteria. Design meets Code minimum (U360) Live load deflection criteria. Design meets arbitrary(1") Maximum total load deflection criteria. .®B COPY Calculations assume member is fully braced. Design based on Dry Service Condition. THIS PLAN MUST BE ON JOB SITE FOR r:AC�1 INSPECTION Page 1 of 2 ®Boise Cascade Double 1-3/4" x 16A VERSA-LAM® 2.0 3100 SP Floor Beam1FB01 gffl Dry I 1 span I No cantilevers 10/12 slope November 10, 2016 07:42:04 BC CALC®Design Report Build 5613 File Name: FB02 Job Name: Description: Designs\FB01 Address: Specifier: City, State, Zip: , Designer: Customer: Company: Code reports: ESR-1040 Misc: Connection Diagram Disclosure Lrel b r. 7 d 7 Completeness and accuracy of input must i be verified by anyone who would rely on a M output as evidence of suitability for • • • a- : particular application.Output here based / on building code-accepted design c /\ properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with • • current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum =2" c= 12" (800)232-0788 before installation. b minimum =2-1/2"d=24" BC CALL®,BC FRAMER®,AJST" Bolts are assumed to be Grade A307 or Grade 2 or higher. ALLJOIST®,BC RIM BOARDTM' BCI®, Member has no side loads. BOISE GLULAMTM SIMPLE FRAMING SYSTEMConnectors are: 1/2 in. Staggered Through Bolt PLUS® ®ERSA R M®M®,VERSA-RIM VERSA-STRAND®,VERSA-STUD®are trademarks of Boise Cascade Wood Products L.L.C. ®Boise Cascade Double 1-3/4" x 166 VERSA-LAM® 2.0 3100 SP Floor Beam1FB02 Dry I 1 span I No cantilevers I 0/12 slope November 10, 2016 07:40:52 BC CALC®Design Report Build 5613 File Name: FB02 Job Name: Description: Designs\FB02 Address: Specifier: City, State,Zip: , Designer: Customer: Company: Code reports: ESR-1040 Misc: 11111111111141\ 1111111111111111111 >2S 03-11-08 BO B1 Total Horizontal Product Length=03-11-08 Reaction Summary(Down/Uplift) (lbs) Bearing Live Dead Snow Wind Roof Live BO, 3-1/2" 1,288/0 781 /0 152/0 B1, 3-1/2" 1,062/0 2,712/0 1,265/0 Live Dead Snow Wind Roof Live Trib. Load Summary Tag Description Load Type Ref. Start End 100% 90% 115% 160% 125% 1 Standard Load Unf. Area(Ib/ft^2) L 00-00-00 03-11-08 40 10 01-00-00 2 T31 Conc. Pt. (lbs) L 00-04-11 00-04-11 742 278 n/a 3 T31 Conc. Pt. (lbs) L 01-08-11 01-08-11 742 278 n/a 4 FB01 Conc. Pt. (lbs) L 03-04-04 03-04-04 708 2,833 1,417 n/a Controls Summary Value %Allowable Duration Case Location Pos. Moment 1,636 ft-lbs 4.4% 100% 1 01-08-11 End Shear 1,017 lbs 9.6% 100% 1 01-07-08 Total Load Defl. U999(0.002") n/a n/a 3 02-00-13 Live Load Defl. U999(0.001") n/a n/a 6 02-00-06 Max Defl. 0.002" n/a n/a 3 02-00-13 Span/Depth 2.6 n/a n/a 0 00-00-00 %Allow %Allow Bearing Supports Dim.(L x W) Value Support Member Material BO Wall/Plate 3-1/2"x 3-1/2" 2,069 lbs 29.9% 22.5% Southern Pine B1 Wall/Plate 3-1/2"x 3-1/2" 4,457 lbs 64.4% 48.5% Southern Pine Notes Design meets Code minimum(0240)Total load deflection criteria. Design meets Code minimum(U360) Live load deflection criteria. Design meets arbitrary(1") Maximum total load deflection criteria. Calculations assume member is fully braced. Design based on Dry Service Condition. Page 1 of 2 • Bole Cascade Double 1-3/4" x 16" VERSA-LAM® 2.0 3100 SP Floor Beam\FB02 11 Dry I 1 span I No cantilevers 10/12 slope November 10, 2016 07:40:52 BC CALC®Design Report Build 5613 File Name: FB02 Job Name: Description: Designs\FB02 Address: Specifier: City, State, Zip: , Designer: Customer: Company: Code reports: ESR-1040 Misc: Connection Diagram Disclosure rel b d \ Completeness enbys anyo a who y f input must LI be verified by anyone who would rely on a output as evidence of suitability for • r• • a.� �, particular application.Output here based T on building code-accepted design c 7\ properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with ' • • d current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call a minimum =2" C= 12" (800)232-0788 before installation. b minimum =2-1/2"d=24" BC CALC®,BC FRAMER®,AJST° Connection design assumes point load is top loaded. For connection design of side loaded ALLJOIST®,BC RIM BOARDT"' BCI®, point loads, please consult a technical representative or professional of Record. BOISE GLULAMTM SIMPLE FRAMING Bolts are assumed to be Grade A307 or Grade 2 or higher. SYSTEM®,VERSA-LAM®,VERSA-RIM 9 PLUS®,VERSA-RIM®, Member has no side loads. VERSA-STRANDS,VERSA-STUD®are Connectors are: 1/2 in. Staggered Through Bolt trademarks of Boise Cascade Wood Products L.L.C.