1655 ATLANTIC BEACH DR - ENERGY SHEETS I JOB COPY
FORM R405-2014
_ FLORIDA ENERGY EFFICIENCY CODE FOS:FAHilibtratinDWIRUCTION
Florida Department of Business and Professional Regul tt i - €i Jn ttIT ocrieice Method
n e�'e R e
i4SPECTIL,,
Project Name: Cumberland 3163 Left Builder Name: olhBro rs
Street: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Office: Atlantic Beach T
City,State,Zip: Atlantic Beach ,FL, Permit Number:
Owner: Toll Brothers Jurisdiction: 261300
Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(4448.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 4266.70 ft'
b.Frame-Wood,Adjacent R=13.0 181.50 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 5 d.N/A R= ft2
10.Ceiling Types (200 0 sqft.) Insulation Area
5. Is this a worst case? No a.Under At j anted) R=38.0 1793.00 ft2
6. Conditioned floor area above grade(ft2) 3163 b.Under tti ted) R=19.0 212.00 ft2
c.N/A aR= ft2
Conditioned floor area below grade(ft2) 0 11.Ducts R ft2
7. Windows(331.0 sqft.) Description` Area a.Sup:Attic,Ret:Attic,AN:2nd Floor 6 425
a. U-Factor: Dbl,U .33 331.00 ft2
SHGC: SHGC 0.30
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
a.Central Unit 42.0 SEER:14.00
SHGC:
. c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
• d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20
. SHGC:
Area Weighted Average Overhang Depth: 3.672 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
a.Natural Gas Tankless Cap:1 gallons .
8. Floor Types (3163.0 sqft.) Insulation Area EF:0.800
a.Slab-On-Grade Edge Insulation R=0.0 2005.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1158.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 67.69 PASS
Glass/Floor Area: 0.105 Total Baseline Loads: 84.42
,,,,,,,,Wa..f.,,,,,,
I hereby certify that the plans and specifications covered by Review of the plans and ,`y01'T•H ,STAT�O
this calculation are in compliance with the Florida Energy specifications covered by this :°� ,.' (1,4 t‘.?- ; �;4
Code. calculation indicates compliance ?co.../, f.•,:. .1 .i.• ;`_ys'�,i
/ -,..1..,4,,,,
with the Florida Energy Code. ti��J+eir.' s �. y�yyy
PREPARED Y: ��-• 4' �� Before construction is completed ,A:=11,. .. - i d
�/f /4 - .
DATE: this building will be inspected for ,52
compliance with Section 553.908 1;, * ',...:4 4 ,,q er 1
I hereby certify that this building,as designed,is in compliance Florida Statutes. �4,,` -',.:'S,C�;�
CPD...•. .0
with the Florida Energy Cod n^ ",•,.,,,,, • °.
I /'/ 1
OWNER/AGENT' A� BUILDING OFFICIAL: / _��_�
DATE: i 2I 29, i , DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed In accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
i
1
FORM R405-2014
PROJECT
Title: Cumberland 3163 Left Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 3163 Lot#
Owner: Toll Brothers Total Stories: 2 Block/SubDivision:
#of Units: 1
Worst Case: No PlatBook:
Builder Name: Toll Brothers Rotate Angle: 0 Street: 1655 Atlantic Beach Dr.
Permit Office: Atlantic Beach Cross Ventilation: No County: Duval
Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach ,
Family Type: Single-family FL,
New/Existing: New(From Plans) •
Comment: ,
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
V FL,Jacksonville FL._JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium
BLOCKS 1
Number Name Area Volume
1 Block/ 3163 30472
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
1 Main 2005 20050 Yes 3 2 1 Yes Yes Yes i
2 2nd Floor .1158 10422 No 3 3 1 Yes Yes Yes
FLOORS
V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
V 1 Slab-On-Grade Edge Insulatlo Maj 212.9 ft 0 2005 ft' ____ 0 0 1
t/ 2 Floor Over Other Space /2nd Flo ____ ____ 1158 ft' 0 0 1
1 ROOF
VRoof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
V 1 Gable or Shed Composition shingles 2322 ft' 586 ft' Medium 0.4 N 0.9 No 0 30.3
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
•
1 Full attic Vented 300 2005 ft' N N
•
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
✓ 1 Under Attic(Vented) 2nd Floor 19 Blown 212 ft' 0.11 Wood
✓ 2 Under Attic(Vented) 2nd Floor 38 Blown 946 ft' 0.11 Wood
V., 3 Under Attic(Vented) Main 38 Blown 847 ft' 0.11 Wood
WALLS
/ Adjacent Cavity Width Height Sheathing Framing Solar Below
V # rlrnt Tn Wall Type Space R_Valna Ft In Ft In AfP9 R-Value Fraction Absor Grade%
V 1 W Exterior Frame-Wood Main 19 19 10 10 0 198.3 ft' 0 0.23 0.5 0
✓ 2 S Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 0.23 0.5 0 4
✓ 3 E Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.5 0
✓ 4 N Exterior Frame-Wood Main 19 76 9 10 0 767.5 ft2 0 0.23 0.5 0
✓ 5 W Garage Frame-Wood Main 13 20 2 9 0 181.5 ft' 0 0.23 0.5 0
'✓ 6 W Exterior Frame-Wood 2nd Floor 19 19 10 10 0 198.3 ft2 0 0.23 0.5 0
Y 7 S Exterior Frame-Wood 2nd Floor 19 76 9 10 0 767.5 ft' 0 0.23 0.5 0
V.
8 E Exterior Frame-Wood 2nd Floor 19 40 0 10 0 400.0 ft' 0 0.23 0.5 0
V 9 N Exterior Frame-Wood 2nd Floor 19 76 9 10 0 767.5 ft2 0 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value FtWidth In Ft Heightln Area
V 1 W Insulated Main None .6 3 8 24 ft'
_L_ 2 W Insulated Main None .6 2 8 8 21.3 ft'
WINDOWS
Orientation shown is the entered,Proposed orientation. ,
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
'7 1 W 1 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft' 6 ft 4 in 1 ft 0 In None Interior 5
V 2 S 2 Vinyl Low-E Double Yes 0.33 0.3 75.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
1/ 3 E 3 Vinyl Low-E Double Yes 0.33 0.3 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5
V 4 E 3 Vinyl Low-E Double Yes 0.33 0.3 72.0 ft2 10 ft 0 in 1 ft 0 in Drapes/blinds Interior 5
✓ 5 N 4 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft2 1 ft 4 In 1 ft 0 in Drapes/blinds Interior 5
l✓ 6 N 4 Vinyl Low-E Double Yes 0.33 0.3 4.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5
V 7 E 8 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5
V 8 S 7 Vinyl Low-E Double Yes 0.33 0.3 45.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5
✓ 9 N 9 Vinyl Low-E Double Yes 0.33 0.3 15.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5
GARAGE
✓ # Floor Area Ceiling Area • Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
_1 1 659 ft' 540 ft' 64 ft 9 ft 1
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
INFILTRATION
# Scope Method
SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000306 2539.3 139.41 262.17 .2901 5
HEATING SYSTEM
Subtype Efficiency Capacity Block Ducts
1 # System Type YP
1 Electric Heat Pump
Split HSPF:8.2 42 kBtu/hr 1 sys#1
COOLING SYSTEM
V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
_\ ,,1.---Central Unit Split SEER:14 42 kBtu/hr 1260 cfm 0.7 1 sys#1
HOT WATER SYSTEM
✓ # System Type SubType Location EF Cap Use SetPnt Conservation
I Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
V FSECCollector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
Jft=
None None
DUCTS
---Supply-- --Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
v` 1 1
1 Attic 6 425 ft2 Attic 106.25 Default Leakage 2nd Floor (Default) (Default)
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling Mar Apr May X Jun X Jul X Au X Se Oct Nov Dec
Heating HJJaann
[xi Mar Apr Ma Jun Jul Aug Sep Oct X Nov X Dec
Jan fFeb XMar [X�Apr May Jun Jul Aug Sep (X�Oct �X�Nov Dec
Venting
I
Page I 12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Pa 9
I
FORM R405-2014
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 800 80 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 8 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 66
MECHANICAL VENTILATION
Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System
None 0 0 0 1-Electric Heat Pump 0% 1-Central Unit
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
I I
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index,the more efficient the home.
1655 Atlantic Beach Dr. (Lot 10 AB) , Atlantic Beach , FL,
New(From Plans) 9. Wall Types Insulation Area
1. New construction or existing a.Frame-Wood,Exterior R=19.0 4266.70 ft2
2. Single family or multiple family Single-family .
b.Frame-Wood,Adjacent R=13.0 181.50 ft2
R= ft2
3. Number of units,if multiple family 1 c.N/A ft2
4. Number of Bedrooms 5 d.N/A R=Insulation Area
10.Ceiling Types
5. Is this a worst case? No a.Under Attic(Vented) . R=38.0 1793.00 ft2
b.Under Attic(Vented) R=19.0 212.00 ft2
6. Conditioned floor area(ft2) 3163 c.N/A R= ft2
7. Windows" Description Area 11.Ducts R ft2
a. U-Factor: Dbl,U=0.33 331.00 ft2 a.Sup:Attic,Ret:Attic.AH:2nd Floor 6 425
SHGC: SHGC=0.30
ft2
S
b. Factor: N/A 12.Cooling systems kBtu/hr Efficiency
SHGC: ft2 a.Central Unit 42.0 SEER:14.00
c. U-Factor: N/A
SHGC:
ft2 kBtu/hr Efficiency ,
d. U-Factor: N/A 13.Heating systems
SHGC: a.Electric Heat Pump 42.0 HSPF:8.20
Area Weighted Average Overhang Depth: 3.672 ft.
Area Weighted Average SHGC: 0.300
8. Floor Types
Insulation Area 14.Hot water systems Cap:1 gallons
Natural Gas
a.Slab-On-Grade Edge Insulation R=0.0 2005.00 ft2 a. EF:0.8
b.Floor Over Other Space R=0.0 1158.00 ft2 b. Conservation features
R= ft2
c.N/A None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building .o��gE Sr,...
Construction through the above energy saving features which will be installed (or exceeded) �.,�,,��, f, _;;o,�
in this home before final inspection. Otherwise, a new EPL Display Card will be completed : c, .G�'' �,`•s
based on installed Code complia -atures. f a;s..,, :,,„_ r
:
` I Date: 121 2$ I I lD •
a c➢', r
Builder Signature `/
Address of New Home: �.D J 5 Ate tight Dr. City/FL Zip:-AB PL. 4'4 ',.0 o''
•
1 SCh coDy �tti,,,•
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
•
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Number:
Atlantic Beach ,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. •
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
• accordance with the manufacturer's Instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes perhour In Climate Zones 3 through 8.Testing shall be conducted with •
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code •
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond Intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if Installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed In accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-In testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be'substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.if the air handler Is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
•
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 Yz inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
o R403.4.4.1 Storage water heater temperature controls
▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
) . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors In installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and sl
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air Intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
O R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
' equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
01 described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected In
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
1
I
I
Ii
1
12/15/2016 4:08 PM EnergyGauge&USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3
•
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed In an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity Is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected In Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,Inground spas and portable spas(Mandatory). The energy requirements for residential pools and
Inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested In accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed In
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
▪ solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently Installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently Installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
I ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be Insulated to a minimum of R-6.
0 R405.2.1 Performance ONLY. Ceilings shall have minimum Insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3
FORM R405-2014 TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Cumberland 3163 Left Builder Name: Toll Brothers
Street: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Office: Atlantic Beach
City,State,Zip: Atlantic Beach ,FL, Permit Number:
. Owner: Toll Brothers Jurisdiction: 261300
•
Design Location: FL,Jacksonville
COMPONENT CRITERIA
CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints In the air barrier shall be sealed.
Air-permeable Insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed. �j
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in "-----J
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation. \.►
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped. .._)
Shafts, penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled \�
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
\—/Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall. \
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in V
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have
gasketed doors
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Cumberland 3163 Left Builder Name: Toll Brothers
Street: 1655 Atlantic Beach Dr.(Lot 10 AB) Permit Office: Atlantic Beach
City,State,Zlp: Atlantic Beach ,FL, Permit Number:
Design Location: FL,Jacksonville Jurisdiction: 261300
Cond.Floor Area:: 3163 sq.ft. Cond.Volume: 30472 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R. CFM(50):
Single or Multi Point Test Data
I HOUSE PRESSURE I FLOW: ( ELA:
EqLA:
ACH:
ACH(50):
SLA:
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2
Inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the Intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond Intended Infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,If installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Where required by the code official, F, zSx� Z :+
performance results demonstrate compliance testing shall be conducted by an ,�; •,t;
with Florida Energy Code requirements in approved third party.A written :C. '" t. `��., <:
accordance with Section R402.4.1.2. report of the results of the test shall ' ;L
be signed by the third party
conducting the test and provided to }''., 114 A
•
SIGNATURE: the code official. 'v41+
D,C° tt-•n,�
PRINTED NAME:
BUILDING OFFICIAL:
DATE: DATE:
12/15/2016 4:08 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
r
4.
o
' • Job: Lot 10 ABCC
McGwan' Project Summary Date:
Cfrid'tlApX11 Entire House By: Stephen Barber
McGowan's Heating & Air Conditioning, Inc.
4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com
Project Information •
For: Toll Brothers
Fl
Notes: Cumberland
Desi• n Information
Weather: Jacksonville NAS, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 °F Outside db 99 °F
75 °F
Inside db 70 °F Inside db 24 °F
Design TD 38 °F Design TD
Daily range M M
Relative humidity 51 gr/lb
Moisture difference
•
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 31869 Btuh Structure 24629 Btuh
Ducts 4398 Btuh Ducts 5559 Btuh
0 Btuh Central vent(0 cfm) 0 Btuh
Central vent(0 cfm) (none)
(none) 0 Btuh Blower 0 Btuh
Humidification g 0 Btuh
Equipment load 36267 Btuh Use manufacturer's data 1 0
Rate/swing multiplier
Infiltration
Equipmei se_ nsi_leload tuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 4275 Btuh
Fireplaces 0 Structure
Ducts 975 Btuh Central vent(0 cfm) 0 Btuh
Heating Cooling (none) Btuh
Area(ft2) 3163 3163 Equipment latent load .C`
Volume(0') 29777 29777Btuh
Air changes/hour 0.28 0.15 Equipment total load—
Equiv.AVF(cfm) 139 74 Req.total capacity at 0.70 SHR 3.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model CH14NB0420000A0 Cond CH14NB0420000A0
AHRI ref 9162578 Coil FB4CNP042L
AHRI ref 9162578 11.5 EER, 14 SEER
Efficiency 8.2 HSPF Efficiency
° 8000 Btuh
Heating input Sensible cooling 2 28000 Btuh
Heating output 41000 Btuh @ 47F Latent cooling 42000 Btuh
Temperature rise 30 °F Total cooling 0000 cfm
Actual air flow 1225 cfm Actual air flow 1225cfm/Btuh
Air flow factor 0.034 cfm/Btuh Air flow factor .041 incf H2O
Static pressure 0.50 in H2O Static pressure 0.85
Space thermostat Load sensible heat ratio
Capacity balance point=30°F
Backup:
Input=9 kW, Output=31117 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2016-Dec-15 15:31:50
, .'•
wrjghtSOft' Comfort Builder by Wrightsoft 17.0.16 RSU12270 Page 1
ACCA ,,.trucbonlToll BrolherslCumberland 3163 Len.n,p Calc=MJ8 Front Door faces: W
N `'�
At First Floor
m.wic II
4 x 8 1
4„
nt.wic 2 master bed
.,... .,
4x8• ' 14x6
4" 7J 14x14 8"
A12" 8x4 •i4
4"4 r..�
4„ od6x12
7„
m.bath
IT
3"Fang]
3"Fan
• J 10"
12 x 12 3"Fan family
I\
8 0i'.th 2
I 6x10 8x4 ,
bed 2 6" s ,, 4" Sup Riser 6 x 12
j 7"
1.
12" hall
J
14x14 12"
12"
stairs
10x10
10x10
r J„
kitchen
6x10
laund. 5" 10 x 6
6"
• •n
O 0
... 8x4
4"
pan.
t
garage t±ci
foyer 12 x 12 14 x 6
12x12 10" 8"
,•, living rm
10x6
6"
..i...).--i,
Job #: Lot 10 ABCCScale: 1 : 101
McGowan's Heating & Air Conditioning,
Performed by Stephen Barber for: Page 1
Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft
Orange Park,FI 32073 17.0.16 RSU12270
Fl Phone:904-278-0339 Fax:904-278-0366 2016-Dec-15 15:33:12
www.mcgowansac.com korey@mcgowansac.com ,..rothers\Cumberland 3163 Left.rup
/1P0 Second Floor
--
bonus rrn
12x6 12x6 12x12
U� .a
8x4 Ifowder 4
10" Hallway
Storage.
10"
16 x 16
•' 14" 14"
S ip Riser
■•s •
14"
14"
6x10-
• 10" 5"
Oak S6
...�� r,� ...
12 x 12
8" J 12x12 14x6
Hwy 2. 10" 8„
10 x 6 Bedroom 4
Bedroom 3 6" ., ••
4x8 8x4
4' 4'
Bath 3 Bath 4
Job#: Lot 10 ABCCScale: 1 : 101
McGowan's Heating & Air Conditioning,
Performed by Stephen Barber for: Page 2
Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft
Orange Park,Fl 32073 17.0.16 RSU12270
Fl Phone:904-278-0339 Fax:904-278-0366 2016-Dec-15 15:33:12
www.mcgowansac.com Korey@mcgowansac.com ...rothers\Cumberland 3163 Left.rup
mcGolwan
Manual S Compliance Report Dae.Lot10ABCC
Heating ci ilr 7. 1 Entire House By: Stephen Barber
Conditioning McGowan's Heating & Air Conditioning, Inc.
4850 Collins Road,Orange Park,A 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com
Project Information
For: Toll Brothers
Fl
Cooling Equipment
Design Conditions
Outdoor design DB: 99.2°F Sensible gain: 29588 Btuh Entering coil DB: 75.9°F
Outdoor design WB: 80.2°F Latent gain: 5850 Btuh Entering coil WB: 63.0°F
Indoor design DB: 75.0°F Total gain: 35438 Btuh
Indoor RH: 50% Estimated airflow: 1225 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB0420000A0+FB4CNP042L
Actual airflow: 1225 cfm
Sensible capacity: 29516 Btuh 100%of load
Latent capacity: 6817 Btuh 117%of load
Total capacity: 36333 Btuh 103%of load SHR: 81%
Heating Equipment
Design Conditions
Outdoor design DB: 31.7°F Heat loss: 36267 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L
Actual airflow: 1225 cfm a Capacity balance: 30 °F
Output capacity: 32380 Btuh 89/o of load p y
Supplemental heat required: 3887 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1225 cfm
Output capacity: 9.1 kW 86%of load Temp.rise: 30 °F
Meets are all requirements of ACCA Manual S.
2016-Dec-15 15:31:50
.� wrightsoft° Comfort Builder by Wrightsoft 17.0.16 RSU12270 Page 1
ACS ...truction\Toll Brothers\Cumberland 3163 Left.rup Calc=MJ8 Front Door faces: W
•
Job: Lot 10 ABCC
McGowairk Duct System Summary Date:
tfastran Entire House By: Stephen Barber
'"--"`nning
..,.«' s
McGowan's Heating & Air Conditioning, Inc.
4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com
Project Information .
For: Toll Brothers
Fl
Heating Cooling
0.50 in H2O 0.50 in H2O
External static pressure 0.11 in H2O 0.11 in H2O
Pressure losses 0.39 in H2O 0.39 in H2O
Available static pressure
Supply/return available pressure 0.243/0.147 in H2O 0.243/0.147 in H2
0
0.091 in/100ft 0.091 in/100ft
Lowest friction rate 1225 cfm 1225 cfm
Actual air flow 430 ft
Total effective length(TEL)
Supply Branch Detail Table
Design Htg CIg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk
Bath 3 h 365 12 11 0.122 4.0 Ox 0 VIFx 19.3 180.0 st6
180.0 st6
Bath 4 h 345 12 10 0.122 4.0 Ox 0 VIFx 19.5
Bedroom 3 h 2613 88 84 0.119 6.0 Ox 0 VIFx 23.7 180.0 st6
Bedroom 4 c 3060 124 124 0.119 8.0 Ox 0 VIFx 23.5 180.0 st6
Oak Stairs:A h 589 20 18 0.124 5.0 Ox 0 VIFx 15.5 180.0 st6
Powder h 279 9 7 0.114 4.0 Ox 0 VIFx 22.6 190.0 st7
Storage:A h 1276 43 34 0.116 4.0 Ox 0 VIFx 20.1 190.0 st7
bath 2 C 36 1 1 0.119 4.0 Ox 0 VIFx 14.5 190.0 st4
bed 2 h 2202 74 59 0.124 6.0 Ox 0 VIFx 11.5 185.0 st4
bonus nn-A c 3104 80 126 0.110 7.0 Ox 0 VIFx 25.0 195.0 st7
bonus rm-B c 3104 80 126 0.110 7.0 Ox 0 VIFx 30.1 190.0 st7
family h 2789 94 89 0.112 7.0 Ox 0 VIFx 26.0 190.0 st4
family-A h 2789 94 89 0.091 7.0 Ox 0 VIFx 37.4 230.0 st5
foyer h 2435 82 76 0.102 6.0 Ox 0 VIFx 44.1 195.0 st3
kitchen c 1732 32 70 0.107 6.0 Ox 0 VIFx 36.5 190.0 st3
laund. C 1041 25 42 0.105 5.0 Ox 0 VIFx 36.0 195.0 st3
living rm h 3951 133 127 0.104 8.0 Ox 0 VIFx 43.5 190.0 st3
m.bath h 704 24 13 0.097 4.0 Ox 0 VIFx 26.0 225.0 st5
m.wic h 1154 39 16 0.091 4.0 Oxo VIFx 37.7 230.0 st5
m.wic 2 h 1015 34 17 0.093 4.0 Ox 0 VIFx 30.6 230.0 st5
master bed h 2967 100 74 0.093 8.0 Ox 0 VIFx 31.0 230.0 st5
pan. h 697 24 9 0.105 4.0 Ox 0 VIFx 42.0 190.0 st3
mc c 12 0 0 0.096 4.0 Ox 0 VIFx 27.5 225.0 st5
2016-Dec-15 15:31:50
wrightsoft' Comfort Builder by Wrightsoft 17.0.16 RSU12270
Page 1
A )"1 ,,.(ruction\Toll Brothers\Cumbedand 3163 Left.rup Calc=MJ8 Front Door faces: W
• Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st3 Peak AVF 296 325 0.102 414 12.0 0 x 0 VinIFIx st1
st5 Peak AVF 291 209 0.091 534 10.0 0 x 0 VinIFIx st4
st4 Peak AVF 461 359 0.091 587 12.0 0 x 0 VinIFIx st1
st1 Peak AVF 757 684 0.091 708 14.0 0 x 0 VinIFIx
st2 Peak AVF 468 541 0.110 506 14.0 0 x 0 ViniFlx
st6 Peak AVF 256 248 0.119 469 10.0 0 x 0 VinIFIx st2
st7 Peak AVF 212 294 0.110 538 10.0 0 x 0 VinIFIx st2
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk
rb8 Ox 0 229 214 133.7 0.110 420 10.0 Ox 0 VIFx illVIFx rt2
rb9 Ox 0 183 231 155.9 0.094 216 14.0 Ox 0 VIFx rt2
rb11 Ox 0 438 433 153.0 0.096 1254 8.0 Ox 0 VIFx rt2
rb10 Ox 0 375 347 162.5 0.091 687 10.0 Ox 0
Return Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in)
Material Trunk
rt1 Peak AVF 1225 1225 0.091 877 16.0 0 x 0 VinIFIx
rt2 Peak AVF 996 1011 0.091 945 14.0 0 x 0 VinIFIx rt1
2016-Dec-15 15:31:50
41.
wrightsoft' Comfort Builder by Wrightson 17.0.16 RSU12270 Page 2
i ...tniction\Toll Brothers\Cumberland 3163 Left.rup Calc=MJ6 Front Door faces: W
McGowan Static Pressure and Friction Rate Date:
xrrvrrnnsAir
CandttkutMg?N Entire House By: Stephen Barber
�'" McGowan's Heating & Air Conditioning, Inc. Job: Lot 10 ABCC
4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com
Project Information
For: Toll Brothers
Fl
Available Static Pressure
Heating Cooling
(in H2O) (in H2O)
External static pressure
0.50 0.50
Pressure losses 0.06 0.0E
Coil 0 0
Heat exchanger 0 02 0.020
Supply diffusers 0.03 0.02
Return grilles 0 2
Filter 0 0
Humidifier 0 0
Balancing damper 0 0
Other device
Available static pressure
0.39 0.39
Total Effective Length
Supply Return
(ft) (ft)
15 17
Measured length of run-out 23 6
Measured length of trunk 230 146
Equivalent length of fittings
0
268 163
Total length 463
Total effective length
Friction Rate
Heating Cooling
(in/100ft) (in/100ft)
0.091 OK 0.091 OK
Supply Ducts 0.091 OK 0.091 OK
Return Ducts
Fitting Equivalent Length Details
Supply 11C=40,4AD=60, 11G=5, 11C=40, 11C=40, 11G=5, 11G=5, 1A=35:TotalEL=230
Return 6L=20, 11C=40, 11G=5, 11C=40,5E2=35:TotalEL=140
2016-Dec-15 15:31:50
Page 1
;y wrightsoft' Comfort Builder by Wrightsoft 17.0.18 RSU12270
jik ...truction\Toll Brothers\Cumberland 3163 Left.rup Calc=MJ8 Front Door faces: W