Loading...
87 W 4TH ST DUPLIX A & B - NEW SERVICE 2 METERS f- S CITY OF ATLANTIC BEACH „pr., w , 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 A-0.1-69%r- ELECTRICAL INSPECTION PHONE LINE 247-5814 A-JSi1Jr ELECTRICAL PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 17-ELEC-3877 Job Type: ELECTRIC ONLY Description: ELECTRIC - DUPLIX 2 METERS, 150 AMPS EACH, 240 VOLTS EACH, SINGLE PHASE Estimated Value: $6,500.00 Issue Date: 5/3/2017 Expiration Date: 10/30/2017 PROPERTY ADDRESS: Address: 87 W 4TH ST A RE Number: None GENERAL CONTRACTOR INFORMATION: Name: ELITE ELECTRICAL SERVICES LLC Michael Charles Schweitzer, EC13005843 Address: 11611 CAPE HORN AVE QA MICHAEL CHARLES SCHWEITZER Phone: - - FEES: State Elec DBPR Surcharge $2.00 State Elec DCA Surcharge $2.00 Multifamily Electrical $100.00 Trade Permit Base Fee $55.00 Total Payments: $159.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUIl MING(:ODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd,Atlantic Beach,FL 32233 h(904)247-5826 Fax(904)247-5845 I 7 -ELEC-3 877 JOB ADDRESS: r � l'l4 - PERMIT# JEA INFORMATION REQUIRED ON ALL PERMITS ,-.0 AMPS Z eVOLTS PHASE VALUE OF WORK4�&' NEW SERVICE ❑ Overhead Xr Underground J Underground up Pole OResidential(Main)Service 00-100 amps x101-150amps 0151-200amps 0 amps #of Meters • 0 Commercial(Main Service 00-100 amps ❑101-150amps 0151-200amps 0 amps OCT Service amps Conductor Type Size Multi-Family(Main)Service 00-100 amps 1 01-150amps 0151-200amps 0 amps #ofUnitMeters E.--- 0 Temporary Pole 0 amps SERVICE UPGRADE 0 amps 0 CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) ❑100 amps 0150amps 0200amps 0 amps OCT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS 0 Swimming Pool 0 Sign 0 Smoke Detectors Qty OTransformers KVA ❑Motors hp FERE ALARM SYSTEM (Requires 3 sets of plans) Qty volts/amps VALUE OF WORK$ REPAIRS/MISCELLANEOUS OReplace Burnt/Damaged� Meter Can [ISafety Inspection OPanel Change 00H to UG ❑Other: /'" ( P/ /50 a /(/' . 4 • Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of'any other state or local law regulation construction or the performance of construction. Property Owners Name 1 5 Phone Number Electrical Company r re /&7'(�Ca( 'i'/�/Ce)Office Phone Fax Co.Address: f( 7 �' + , e. < City State f/- Zip ,71V License Holder(Print): / l' �1i0 ( Stat- -_ ification/Registration# IC'POW, N';.. -:; - ,i#=fin older i� � r0 :: I . ;�, ,u ,,,: MY COMMISSION�FF 924951 20_f "" EXPIRES:October 6,2019 • Before me this day o 1,A • J 'Azov Bonded Thru Notay Public Underwriters Signature of Notary Public IM = I