1433 BEACH AVE - DECK PERMIT . i.ay;.
el
,41 Itr t1 CITY OF ATLANTIC BEACH
P '` ? 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
n �%' INSPECTION PHONE LINE 247-5814
RESIDENTIAL ADDITION - SINGLE OR TWO FAMILY RESIDENTIAL ADDITION
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: 17-DECK-2983
Description: reconstruct east deck &reconstruct roof deck to 2nd floor d
Estimated Value: 25000
Issue Date:
Expiration Date:
PROPERTY ADDRESS:
Address: 1433 BEACH AVE
RE Number: 170303 0000
PROPERTY OWNER:
Name: IDYLL HOUR LLC
Address: 1433 BEACH AVE
ATLANTIC BEACH, FL 32233-5733
GENERAL CONTRACTOR INFORMATION:
Name: BOSCO BUILDING CONTRACTORS
Address: 2158 MAYPORT RD
ATLANTIC BEACH, FL32233
Phone: 9042410320
Name: BOSCO BUILDING CONTRACTORS
Address: 2158 MAYPORT RD
ATLANTIC BEACH, FL 32233
Phone: 9042410320
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
1
0
II
01,Altf, City of Atlantic Beach APPLICATION NUMBER
dBuilding Department (To be assigned by the Building Department.)
ill
ji800 Seminole Road _ (�
15..._ �r Atlantic Beach, Florida 32233-5445 �l I }'�"GK act
I Phone(904)247-5826 • Fax(904)247-5845 l I W, Ill
o;; 0. E-mail: building-dept@coab.us Date routed:
City web-site: http://www.coab.us - —
•
APPLICATION REVIEW AND TRACKING FORM
Property Address: 1 3 3 IiikilttiA Ay I_ Department review required Yey No
LQ-717g ng t/
Applicant: (k)SC-0 ( k-t:k k�I C' Planning &Zoning
1i�/ -(p� ,h Tree Administrator
Project: 6`-e-0(--- c Q, 0.ii ` ( -LI(� O(i�.\ QRd Public Works
/c`tOL a i - Public Utilities
" 1 `� Public Safety
Fire Services
'Review fee $ Dept 'signature f
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: 9Approved. ❑Deni d.
(Circle one.) Comments:fro Va/v-e (Yt) (eec,oto/--J.0r) J 'r j i 14 p I i ca+>O'%-
BUILDING / i 66- ? ? O14. - 5711- ( t `i
PLANNING &ZONING Reviewed by: Date: /".2 3-!"
TREE ADMIN. Second Review: ❑Approved as revised. ['Denied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ❑Denied.
Comments:
Reviewed by: Date:
Revised 05/14/09
I
ssy�`J City of Atlantic Beach
Building Department APPLICATION NUMBER
(To be assigned by the Building Department.)
800 Seminole Road
•;,t :5' Atlantic Beach, Florida 32233-5445 `'� ^()ELK- act 3
'"91.;:i = Phone(904)247-5826 • Fax(904)247-5845
1.0 E-mail: building-dept@coab.us Date routed: '1 I la (I
City web-site: http://www.coab.us
•
APPLICATION REVIEW AND TRACKING FORM
Property Address: 3 (ik1 AVL Department review required Yes No
uildin
Applicant: (OS(--F) k-d-:i (,, Planning &Zoning
Tree Adminisfrator
Project: c Q, cC c I (t 0.0 ck\ i n Public Works
Atm_ t - Public Utilities
61(-) Public Safety
Fire Services
:Review fee $
Dept Signature
Other Agency Review or Permit Required Review or Receipt
of Permit Verified By Date
Florida Dept.of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
' Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ,Egpproved. denied.
(Circle one.) Comments: •
BUILDING
; I
PLANNING &ZONING
. Reviewed
TREE ADMIN. Second Review: [Approved as revised. ['Denied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review:
QApproved as revised. ['Denied.
Comments:
Reviewed by: Date:
'ised 05/14/09
,;. j.A.N- , , CITY OF ATLANTIC BEACH
,) _.'- A:
. . 800 Seminole Road
'i f Atlantic Beach, Florida 32233
1 c) Telephone(904)247-5800
0 X FAX (904)247-5845
rl '3I9.-
,j REVISION REQUEST SHEET OR
2 1/17
CORRECTIONS TO REVIEW COMMENT
L/4
Date-4441' Received by: Resubmitted:
Permit Number: 17-RAAR-2955
Original Plans Examiner: Mike Jones Project Name: Morris Residence
Project Address: 1433 Beach Ave,Atlantic Beach, FL
Contractor: Bosco Building Contractors, Inc. Contact Name: Todd Bosco&Josh Rotta
Contact Phone : 904-241-0320 Contact e-mail: Todd@BoscoCBC com:Josh@RoshoCRC corn
Revision/Plan Check/Permit Fee(s) Due: $ 5C', O C)
Description of Proposed Revision to Existing Permit:
Architectural Drawing are already approved and on jobsite,additional copies provided as reference.
First submittal of the structural engineering
Additional Increase in Building Value: $ 0 Additional S.F. o
Site Plan Revised: Public W/U Approval:
By signing below. I (print name) Joshua M. Rotta affirm that the above revision
is inclusive of the pro osed chan s.
/2 3/1/17
Signature of tractor/ gent(Contractor must sign if increase in valuation) Date
Office Use(hely
APP 21 2017 i
a�/!kite: / 2/ — 1 2 Approved: Rejected: Notified by:
Plan Review Comments:
ent review required Yes No
ildin
Planning &Zoning Plans Examiner
Tree Administrator
Public Works Mg 9-2/‘ /7
Public Utilities
Public Safety Date Created 4,'13 Iti Rev)
Fire Services
BUILDING PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Road, Atlantic Beach, FL 32233 OFFICE COPY
Office (904) 247-5826 Fax (904) 247-5845
Job Address: 1433 Beach Ave, Atlantic Beach, FL 32233 Permit Number: 11 - 'OE-C K $_3
Legal Description 6-1 16-2S-29E Atlantic Beach Lots 4,5 Blk 61 Parcel # RE 170303-0000 -
Floor Area of Sq.Ft. Sq.Ft
-
Valuation of Work $ 4,5"; Proposed Work heated/cooled 3029 non-heated/cooled 3076
Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s) (circle one): Commercial Residential I
If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No N/A
Florida Product Approval #
For multiple products use product approval form
Describe in detail the type of work to be performed: Reconstructing east facing deck in the same footprint.
Reconstructing roof over east deck to second floor deck
Property Owner Information:
Name: Idyll Hour, LLC Address: 1433 Beach Ave
City Atlantic Beach State FL Zip 32233 Phone
E-Mail or Fax#(Optional)
Contractor Information:
Company Name: Bosco Building Contractors, Inc. Qualifying Agent: Todd A. Bosco
Address: 2158 Mayport Rd City Jacksonville State FL Zip 32233
Office Phone 904-241-0320 Job Site/Contact Number 904-241-0320 Fax# 904-241-0326
State Certification/Registration# CBC 1250212
Architect Name& Phone# —
Engineer's Name&Phone# 1 .1
Fee Simple Title Holder Name and Address
Bonding Company Name and Address
Mortgage Lender Name and Address JAN 1 1 2017
Application is hereby made to obtain a permit to do the work and installations as indicated. I certOrthat no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet the standards of all laws regulating consthiction in this jurisdiction. This permit becomes null
and void if work is not commenced within six(6)months,or if construction or work is suspended or abandoned fbr a period of six(6)months at any time after
work is commenced. 1 understand that separate permits must be securedfor.Electrical Work,Plumbing,Signs, Wells, Pools, Furnaces, Boilers, Heaters,
Tanks and Air Conditioners,etc.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
I hereby certify that 1 have read and examined this plication and know the same to be true and correct. All provisions of laws and ordinances governing this
type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the
provisions of any other federal,state, or local law regulating construction or the performance of construction.
1
Signature of Owner #keye"A fie/otter Signature of Contractor Ale,
Print Name (j 'il iC.t,-, ,/0(1)) Print Name Todd A. Bosco
Swo to and subscribed before me Swornto and subscribed before me
this �` Day of r\qei uaz,c v) , 201`1 this AL Day of V_ �t c u..c icv) , 20 V1
I tti;.0._,,ciki� > Denise A.Ennis _ Denise A.Ennis
NOTARY Pu6LIC NOTARY PUBLIC
Public P _STATE OF FLORIDA rY Pu 1c .. '_STATE OF FLORIDA
Comm./FF98111426 • .s26
Expires 3/1/2020 txpires 3/1/2020
D•Part
a+ STATE OF FLORIDA
o` '' DEPARTMENT OF ENVIRONMENTAL PROTECTION
'. Division of Water Resource Management
P. 2600 Blair Stone Road—Mail Station 3522
Tallahassee, Florida 32399-2400
0 0
4 L
O �+
'i+nta' V�
PERMIT NUMBER: DU-497
PERMITTEE
Idyll Hour,LLC
c/o Todd Bosco OFFICE COPY
Bosco Building Contractors,Inc.
2158 Mayport Road
Jacksonville,Florida 32233
NOTICE TO PROCEED AND PERMIT FOR CONSTRUCTION OR OTHER
ACTIVITIES PURSUANT TO SECTION 161.053,FLORIDA STATUTES
FINDINGS OF FACT: An application for authorization to conduct the activities seaward of the coastal
construction control line that are indicated in the project description,was filed by the applicant/permittee named
herein on October 12,2016,and determined to be complete pursuant to rule on January 26,2017. The proposed
project is to be located landward of the 30-year erosion projection and the existing line of construction
established by major structures in the immediate area.
CONCLUSIONS OF LAW: After considering the merits of the proposal and any written objections from
affected persons,the Department finds that upon compliance with the permit conditions,the activities indicated
in the project description of this permit are of such a nature that they will result in no significant adverse impacts
to the beach/dune areas or to adjacent properties;that the work is not expected to adversely impact nesting sea
turtles, their hatchlings, or their habitat; and that the work is expendable in nature and/or is appropriately
designed in accordance with Section 62B-33.005, Florida Administrative Code. Based on the foregoing
considerations,the Department approves the application;authorizes construction and/or activities at the location
indicated below in strict accordance with the project description, the approved plans and the General Permit
Conditions which are attached and are by this reference incorporated herein, and any additional conditions
shown below,pursuant to Section 161.053(4),Florida Statutes.
EXPIRATION DATE: April 20,2020
LOCATION: Between approximately 65 feet and 115 feet south of the Department of Environmental
Protection's reference monument R-47, in Duval County. Project Address: 1433 Beach Avenue,Atlantic Beach.
PROJECT DESCRIPTION:
Landward Swimming Pool
1. Location relative to control line: Approximately 86 feet seaward,as measured to the northeast corner.
2. Exterior dimensions: Swimming pool is approximately 12.0 feet in the shore parallel direction by 51.0
feet in the shore-normal direction.
3. Type of foundation: Pilings.
PERMITTEE: Idyll Hour,LLC
PERMIT NUMBER: DU-497
PAGE 2 OFFICE COPY
4. Deck elevation of swimming pool: Approximately+21.2 feet(NAVD).
5. Bottom elevation of swimming pool: 15.4 feet(NAVD).
6. Maximum depth of swimming pool: 5.6 feet.
7. Total volume of excavation: Approximately 75.5 cubic yards.
Excavation/Fill
1. Total volume of excavation: Approximately 75.5 cubic yards. Volume of net excavation: None. All
excavated material will be used on site for fill.
2. Location of excavation: From approximately 35 feet to 86 feet seaward of the control line.
3. Volume of fill to be placed: Approximately 75.5 cubic yards.
4. Location of fill to be placed: From approximately 125 feet to 189 feet seaward of the control line. See
Special Permit Condition 2.
Other Structures/Activities
1. Demolition. See Special Permit Condition 4.
2. Post-supported ground-level wood pool deck extension, varying in width from 5 feet to 23.5 feet,
extending approximately 91 feet seaward of the control line.
3. Reconstruction of a post-supported ground-level wood deck extension along the east side of an existing
ground-level wooden deck, extending approximately 149 feet seaward of the control line as measured
to the southeast corner.
4. Post-supported second-story balcony on the seaward side of the dwelling, extending approximately
132.5 feet seaward of the control line.
5. Pool fence along the south side of the property.
6. Pool equipment pad on the south side of the existing dwelling.
7. Landward paver deck on the west and northwest sides of the pool,between the dwelling and the landward
garage.
8. Landward fireplace on the north end of the paver deck.
9. Landscape plantings. See Special Permit Condition 6.
10. Exterior and pool lighting. See Special Permit Condition 7.
PERMITTEE: Idyll Hour,LLC
PERMIT NUMBER: DU-497 OFFICE COPY
PAGE 3
SPECIAL PERMIT CONDITIONS:
1. Prior to commencement of construction activity authorized by this permit,a preconstruction conference
shall be held at the site among the contractor, the owner or authorized agent, and a staff representative
of the Department to establish an understanding among the parties as to the items specified in the special
and general conditions of the permit.The proposed locations of the structures shall be staked out for the
conference. Contact Trey Hatch at 904/655-1765 or trey.hatch@dep.state.fl.us to schedule a
preconstruction conference.
2. Prior to commencement of construction activity authorized by this permit, a temporary construction
fence shall be erected along the perimeter of the permitted activity.The fence shall remain in place until
the construction authorized by this permit is complete. The optimum siting of the construction fence
shall be determined during the preconstruction conference by the staff representative of the Department
so as to provide maximum protection to the existing vegetation located on the site.
3. No construction, operation, transportation or storage of equipment or materials, and no temporary
lighting of the construction area is authorized in sea turtle nesting habitat, on or seaward of the frontal
dune crest or rigid coastal protection structure in marine turtle nesting habitat at any time during the sea
turtle nesting season(May 1 through October 31).
4. All rubble and debris resulting from this construction shall be removed to a location landward of the
coastal construction control line.
5. All material to be excavated seaward of the coastal construction control line as part of construction
authorized under this permit shall remain in and be placed in areas seaward of the coastal construction
control line.
6. Prior to completion of construction activities authorized by this permit, the permittee shall plant a mix
of a minimum of three native salt-tolerant species to restore any disturbed natural area seaward of the
authorized structures, including areas disturbed by fill. Dune restoration plantings shall consist of salt-
tolerant species indigenous to the native plant communities existing on or near the site or with other
native species approved by the Department. Sod composed of non-native grasses is not authorized into
dune vegetation, located approximately 190 feet seaward of the control line. Plantings in other areas of
the project site shall not include invasive nuisance plant species,such as listed in the Florida Exotic Pest
Plant Council's List of Category I and II Invasive Species and including Asparagus fern (Asparagus
densiflorus).
7. All lighting shall be installed and maintained as depicted in the approved lighting schematic.Underwater
pool lighting shall be permanently fixed to amber or red LED or equivalent and provide no more than'''A
foot candle per square foot of pool surface area.There may be a decrease in the wattage of each approved
lamp and a decrease in the total number of each approved fixture without submitting a modified lighting
plan for review and approval. However, if a fixture or lamp is changed to a different type,manufacturer
or catalog number for any reason, or if the location of any fixture is changed it shall be submitted for
review and approval by the Department prior to installation.No additional permanent exterior lighting
is authorized.
. OFFICE COPY
PERMITTEE: Idyll Hour,LLC
PERMIT NUMBER: DU-497
PAGE 4
8. Permittee shall submit compliance reports as specified in Special and General Permit Conditions of this
permit. General Permit Conditions 1(q), and 1(s) pertain to written reports which must be submitted to
the Department of Environmental Protection at specified times.The forms for the reports: 1(q)Periodic
Progress Report(DEP Form 73-111)and 1(s)Final Certification(DEP Form 73-115B)are available at
http://www.dep.state.fl.us/beaches/forms.htm#CCCL. Each form may be submitted electronically. The
periodic reports are due in the office on a monthly basis. No progress reports are required until such
time as construction activities have started.
GENERAL PERMIT CONDITIONS
(1) The following general permit conditions shall apply, unless waived by the Department or modified by
the permit:
(a)The permittee shall carry out the construction or activity for which the permit was granted in accordance
with the plans and specifications that were approved by the Department as part of the permit. Deviations
therefrom, without written approval from the Department, shall be grounds tor suspension of the work and
revocation of the permit pursuant to Section 120.60(7), F.S., and shall result in assessment of civil fines or
issuance of an order to alter or remove the unauthorized work, or both.No other construction or activities shall
be conducted.No modifications to project size,location,or structural design are authorized without prior written
approval from the Department. A copy of the notice to proceed shall be conspicuously displayed at the project
site. Approved plans shall be made available for inspection by a Department representative.
(b)The permittee shall conduct the construction or activity authorized under the permit using extreme care
to prevent any adverse impacts to the beach and dune system,marine turtles,their nests and habitat,or adjacent
property and structures.
(c) The permittee shall allow any duly identified and authorized member of the Department to enter upon
the premises associated with the project authorized by the permit for the purpose of ascertaining compliance
with the terms of the permit and with the rules of the Department until all construction or activities authorized
or required in the permit have been completed and all project performance reports, certifications, or other
documents are received by the Department and determined to be consistent with the permit and approved plans.
(d)The permittee shall hold and save the State of Florida, the Department, and its officers and employees
harmless from any damage, no matter how occasioned and no matter what the amount, to persons or property
that might result from the construction or activity authorized under the permit and from any and all claims and
judgments resulting from such damage.
(e)The permittee shall allow the Department to use all records,notes,monitoring data,and other information
relating to construction or any activity under the permit,which are submitted,for any purpose necessary except
where such use is otherwise specifically forbidden by law.
(f)Construction traffic shall not occur and building materials shall not be stored on vegetated areas seaward
of the control line unless specifically authorized by the permit. If the Department determines that this
requirement is not being met, positive control measures, such as temporary fencing, designated access roads,
adjustment of construction sequence, or other requirements, shall be provided by the permittee at the direction
of the Department.Temporary construction fencing shall not be sited within marine turtle nesting habitats.
(g)The permittee shall not disturb existing beach and dune topography and vegetation except as expressly
authorized in the permit.Before the project is considered complete,any disturbed topography or vegetation shall
be restored as prescribed in the permit with suitable fill material or revegetated with appropriate beach and dune
vegetation.
(h)All fill material placed seaward of the control line shall be sand which is similar to that already existing
on the site in both coloration and grain size. All such fill material shall be free of construction debris, rocks,
clay,or other foreign matter; shall be obtained from a source landward of the coastal construction control line;
and shall be free of coarse gravel or cobbles.
(i)If surplus sand fill results from any approved excavation seaward of the control line, such material shall
PERMITTEE: Idyll Hour,LLC OFFICE COPY
PERMIT NUMBER: DU-497
PAGE 5
be distributed seaward of the control line on the site,as directed by the Department,unless otherwise specifically
authorized by the permit.
(j) Any native salt-tolerant vegetation destroyed during construction shall be replaced with plants of the
same species or,by authorization of the Department,with other native salt-tolerant vegetation suitable for beach
and dune stabilization.Unless otherwise specifically authorized by the Department, all plants installed in beach
and coastal areas — whether to replace vegetation displaced, damaged, or destroyed during construction or
otherwise — shall be of species indigenous to Florida beaches and dunes, such as sea oats, sea grape, saw
palmetto, panic grass, saltmeadow hay cordgrass, seashore saltgrass, and railroad vine, and grown from stock
indigenous to the region in which the project is located.
(k) All topographic restoration and revegetation work is subject to approval by the Department, and the
status of restoration shall be reported as part of the final certification of the actual work performed.
(1) If not specifically authorized elsewhere in the permit, no operation, transportation, or storage of
equipment or materials is authorized seaward of the dune crest or rigid coastal structure during the marine turtle
nesting season. The marine turtle nesting season is May 1 through October 31 in all counties except Brevard,
Indian River, St. Lucie, Martin, Palm Beach, and Broward counties where leatherback turtle nesting occurs
during the period of March 1 through October 31.
(m)If not specifically authorized elsewhere in the permit, no temporary lighting of the construction area is
authorized at any time during the marine turtle nesting season and no additional permanent exterior lighting is
authorized.
(n)All windows and glass doors visible from any point on the beach must be tinted to a transmittance value
(light transmission from inside to outside)of 45%or less through the use of tinted glass or window film.
(o) The permit has been issued to a specified property owner and is not valid for any other person unless
formally transferred. An applicant requesting transfer of the permit shall sign two copies of the permit transfer
agreement form, agreeing to comply with all terms and conditions of the permit, and return both copies to the
Department. The transfer request shall be provided on the form entitled "Permit Transfer Agreement"—DEP
Form 73-103 (Revised 1/04), which is hereby adopted and incorporated by reference. No work shall proceed
under the permit until the new owner has received a copy of the transfer agreement approved by the Department.
A copy of the transfer agreement shall be displayed on the construction site along with the permit. An expired
permit shall not be transferred.
(p)The permittee shall immediately inform the Department of any change of mailing address of the permittee
and any authorized agent until all requirements of the permit are met.
(q)For permits involving major structures or activities,the permittee shall submit to the Department periodic
progress reports on a monthly basis beginning at the start of construction and continuing until all work has been
completed. If a permit involves either new armoring or major reconstruction of existing armoring, the reports
shall be certified by an engineer licensed in the State of Florida.The permittee or engineer,as appropriate,shall
certify that as of the date of each report all construction has been performed in compliance with the plans and
project description approved as a part of the permit and with all conditions of the permit, or shall specify any
deviation from the plans,project description, or conditions of the permit.The report shall also state the percent
of completion of the project and each major individual component. The reports shall be provided to the
Department using the form entitled "Periodic Progress Report"—DEP Form 73-111 (Revised 6/04), which is
hereby adopted and incorporated by reference.Permits for minor structures or activities do not require submittal
of periodic reports unless required by special permit condition.
(r) For permits involving habitable major structures, all construction on the permitted structure shall stop
when the foundation pilings have been installed.At that time the foundation location form shall be submitted to
and accepted by the Department prior to proceeding with further vertical construction above the foundation.The
form shall be signed by a professional surveyor,licensed pursuant to Chapter 472,F.S.,and shall be based upon
such surveys performed in accordance with Chapter 472, F.S., as are necessary to determine the actual
configuration and dimensioned relationship of the installed pilings to the control line.The information shall be
provided to the Department using the form entitled"Foundation Location Certification"—DEP Form 73-114B
PERMITTEE: Idyll Hour,LLC OFFICE COPY
PERMIT NUMBER: DU-497
PAGE 6
(Revised 9/05), which is hereby adopted and incorporated by reference. Phasing of foundation certifications is
acceptable. The Department shall notify the permittee of approval or rejection of the form within seven (7)
working days after staff receipt of the form.All survey information upon which the form is based shall be made
available to the Department upon request. Permits for repairs or additions to existing structures with
nonconforming foundations are exempt from this condition.
(s) For permits involving major structures, the permittee shall provide the Department with a report by an
engineer or architect licensed in the State of Florida within thirty(30)days following completion of the work.
The report shall state that all locations specified by the permit have been verified and that other construction and
activities authorized by the permit have been performed in compliance with the plans and project description
approved as a part of the permit and all conditions of the permit; or shall describe any deviations from the
approved plans, project description, or permit conditions, and any work not performed. Such report shall not
relieve the permittee of the provisions of paragraph 62B-33.0155(1)(a), F.A.C. If none of the permitted work is
performed, the permittee shall inform the Department in writing no later than 30 days following expiration of
the permit.The report shall be provided on the form entitled"Final Certification"DEP Form 73-115B(Revised
9/05),which is hereby adopted and incorporated by reference.
(t) Authorization for construction of armoring or other rigid coastal structures is based on an engineering
review and assessment of the design and anticipated performance and impact of the structure as a complete unit.
Construction of any less than the complete structure as approved by the Department is not authorized and shall
result in the assessment of an administrative fine and the issuance of an order to remove the partially constructed
structure. Modifications to the project size, location, or structural design shall be authorized by the Department
in accordance with Rule 62B-33.013,F.A.C.
(2) The permittee shall not commence any excavation, construction, or other physical activity on or
encroaching on the sovereignty land of Florida seaward of the mean high water line or,if established,the erosion
control line until the permittee has received from the Board of Trustees of the Internal Improvement Trust Fund
the required lease, license,easement,or other form of consent authorizing the proposed use.
(3) The permittee shall obtain any applicable licenses or permits required by Federal, state, county, or
municipal law.
(4)This permit does not authorize trespass onto other property.
(5)In the event of a conflict between a general permit condition and a special permit condition,the special
permit condition shall prevail.
(6) Copies of any forms referenced above can be obtained by writing to the Department of Environmental
Protection, 2600 Blair Stone Road, MS 3522, Tallahassee, Florida 32399-2400, or by telephoning (850)245-
8336.
Approved plans are incorporated into this permit by reference.
Executed in Tallahassee, Florida.
STATE OF LORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION
Fritz WeSstein, Environmental Consultant
Coastal onstruction Control Line Program
PERMITTEE: Idyll Hour, LLC OFFICE COPY
PERMIT NUMBER: DU-497
PAGE 7
CERTIFICATE OF SERVICE
The undersigned duly designated deputy clerk hereby certifies that this permit and all copies were sent on the
filing date below to the following listed persons:
Todd Bosco,Bosco Building Contractors, Inc.,Todd@BoscoCBC.com
Trey Hatch,FDEP Field Inspector,trey.hatch@dep.state.fl.us
Dan Arlington,City of Atlantic Beach Building Department,darlington(a,,coab.us
Josh Rotta, Bosco Building Contractors, Inc.,Josha,boscocbc.com
FILING AND ACKNOWLEDGMENT
FILED,on this date,pursuant to Section 120.52,F. S.,with the designated Department Clerk,receipt of which
is hereby acknowledged.
C�(1 1C iC� '` `J 04/20/2017
Clerk Date
NOTICE OF RIGHTS
This action is final and effective on the date filed with the Clerk of the Department unless a petition for an
administrative hearing is timely filed under sections 120.569 and 120.57, Florida Statutes, before the deadline
for filing a petition. On the filing of a timely and sufficient petition, this action will not be final and effective
until further order of the Department. Because the administrative hearing process is designed to formulate final
agency action, the hearing process may result in a modification of the agency action or even denial of the
application.
Petition for Administrative Hearing
A person whose substantial interests are affected by the Department's action may petition for an administrative
proceeding(hearing)under sections 120.569 and 120.57,Florida Statutes. Pursuant to rule 28-106.201,Florida
Administrative Code,a petition for an administrative hearing must contain the following information:
(a) The name and address of each agency affected and each agency's file or identification number,
if known;
(b) The name, address, and telephone number of the petitioner; the name, address, and telephone
number of the petitioner's representative, if any, which shall be the address for service purposes during the
course of the proceeding; and an explanation of how the petitioner's substantial interests are or will be affected
by the agency determination;
(c) A statement of when and how the petitioner received notice of the agency decision;
(d) A statement of all disputed issues of material fact. If there are none,the petition must so indicate;
(e) A concise statement of the ultimate facts alleged, including the specific facts that the petitioner
contends warrant reversal or modification of the agency's proposed action;
(f) A statement of the specific rules or statutes that the petitioner contends require reversal or
modification of the agency's proposed action, including an explanation of how the alleged facts relate to the
specific rules or statutes; and
(g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner
wishes the agency to take with respect to the agency's proposed action.
PERMITTEE: Idyll Hour, LLC
PERMIT NUMBER: DU-497 OFFICE C PY
PAGE 8
The petition must be filed (received by the Clerk) in the Office of General Counsel of the Department at 3900
Commonwealth Boulevard,Mail Station 35,Tallahassee,Florida 32399-3000. Also,a copy of the petition shall
be mailed to the applicant at the address indicated above at the time of filing.
Time Period for Filing a Petition
In accordance with rule 62-110.106(3),Florida Administrative Code,petitions for an administrative hearing by
the applicant must be filed within 21 days of receipt of this written notice. Petitions filed by any persons other
than the applicant,and other than those entitled to written notice under section 120.60(3),Florida Statutes,must
be filed within 21 days of publication of the notice or within 21 days of receipt of the written notice,whichever
occurs first. Under section 120.60(3),Florida Statutes,however,any person who has asked the Department for
notice of agency action may file a petition within 21 days of receipt of such notice, regardless of the date of
publication. The failure to file a petition within the appropriate time period shall constitute a waiver of that
person's right to request an administrative determination (hearing) under sections 120.569 and 120.57, Florida
Statutes, or to intervene in this proceeding and participate as a party to it. Any subsequent intervention (in a
proceeding initiated by another party)will be only at the discretion of the presiding officer upon the filing of a
motion in compliance with rule 28-106.205,Florida Administrative Code.
Extension of Time
Under rule 62-110.106(4),Florida Administrative Code,a person whose substantial interests are affected by the
Department's action may also request an extension of time to file a petition for an administrative hearing. The
Department may, for good cause shown, grant the request for an extension of time. Requests for extension of
time must be filed with the Office of General Counsel of the Department at 3900 Commonwealth Boulevard,
Mail Station 35, Tallahassee, Florida 32399-3000, before the applicable deadline for filing a petition for an
administrative hearing. A timely request for extension of time shall toll the running of the time period for filing
a petition until the request is acted upon.
Mediation
Mediation is not available in this proceeding.
Judicial Review
Once this decision becomes final,any party to this action has the right to seek judicial review pursuant to section
120.68,Florida Statutes, by filing a Notice of Appeal pursuant to rules 9.110 and 9.190,Florida Rules of
Appellate Procedure,with the Clerk of the Department in the Office of General Counsel,3900 Commonwealth
Boulevard,M.S.35,Tallahassee,Florida 32399-3000;and by filing a copy of the Notice of Appeal accompanied
by the applicable filing fees with the appropriate District Court of Appeal. The Notice of Appeal must be filed
within 30 days from the date this action is filed with the Clerk of the Department.
Newspaper Publication
The Agency will not publish or require the person requesting a permit to publish in a newspaper a notice of
receipt of the permit application or notice of Agency action granting or denying the permit.
Persons receiving a permit are advised that interested parties who become aware of Agency action approving or
denying the permit, or who observe work on the project within certain time frames without any prior notice,
may have rights to petition for an administrative hearing under Chapter 120,F.S. For this reason, it may be in
the best interest of the person proposing the activity to publish, at its expense, a one-time "Notice of Permit
Issuance" in a newspaper of general circulation in the county where the activity is located meeting the
requirements of Chapter 50, F.S. Agency staff can provide persons with the information for such a notice upon
PERMITTEE: Idyll Hour, LLC OFFICE COPY
PERMIT NUMBER: DU-497
PAGE 9
request. Persons who are substantially affected by the proposed action may petition for an administrative
hearing within the time frames specified in the notice and Chapter 120,F.S.
e ,
LED MINIDISC LIGHT NOW DIMMABLE! a �.` OFFICE C0PY
4 `i.
SCHEMATICS: rM• APPLICATIONS.
t ► Steps o Information Lighting
► Aisles ► Decorah*Lighting
;illr e0o Paths p Merchand.sirg
s
► Direction Lighting ► landscape Agents
i
DESCRIPTION:
Die cast aluminum,or stainless steel,recessed mini LED accent fixture cath prism cover design.Low 3 24watt LED provides BO%energy
savings vs Xenon/Halogen tednology.Dimmable.Fixure circuitry allows expandable system design tort 1 to 200 fixtures per appropriate
Class 1 LED d:lve:E f L listed for In•wail,in4Iocr,outdoor wet and outdoor burial applications.Offered In tut LED colors and five fixture finishes.
FEATURES -
.. . 5 lioture finishes:
i •Sale 11 volt Cass 2 — A:uminum.Black Mite.
Pier tWFly --11. *it 17:. _ 4—Biome,Stsmu Steel
(remote)
•Up to lad fixtures _
per oovxr tingly
•Dnnmable •Fits in any 1-diameter Tule.i V2'long \I�
•wr
Sr i,Ck ra
•to mil appsuatmss
L=0 RL;dule •a.Boor aFprcations
•Lo'u,energy regtdrements of C 24-.vast per fictive •Orrbor Wet.oral an
•61 FD colors Warm Wnrte.Cool whet,Greco.Blue.Red Amber •Duclsnr burial is:aoora
ORDERING LOGIC: XX.LEO COLOR yr=FIXTURE FINISH
LEJrAO-XX•YY W.N.Warm V.-a :3
r aft arze^ ftu:^i.> en OK-Back
CW.Cot:.'.AM,e Nit.anit BZ=Nag SS=Sar.es:Sled
B._.3''a RD=Red WS Wh.te
SPECIFICATIONS:
Voltage 12'1DC
fixture Energy Rating I2VDC,45mA,023atm
LED Color Temperature Warm Wh.te 3800K+I.200K Cool Mr to 7000K+r-2CK
LED Life Rated at 40,003 hoses
LED Colors Warm More.Cool White.Green.Bi,e,Red,Amber
Cover Finish Aluminum,Mite,Bronze,Black.Starless Steel
Barrel Finish Aluminum.White.Bronze,Black,Stainless Steel '
Construction Both liner and barrel are die cast aluminum for corroson protec:ron,strength,weight,and ctrsrstency of finish. . .
Lens Frosted Tempered Glass w 3
Wiring Options Up to2C0I Oise Lights per LED Driver by parallel wnrrrx,I("daisy chain'}te•.ta ten Batsaes # jrIt
Ona wire completes chain No(Wort coed required NOTE Use LW-18G C12 for at n wart applications •s�V' ,6
Use LW-I BG BUR for all outdoor and t nal applicators. sij � 1r `
Dimming Dimmable with appropriate LED Magnetic Power Supply and simmer.See instructions for details. , no�
Agency Approval ER listed and labeled for wet.IC,cedirg,and d rent burial applications. I's
Warranty Two years ahrminun or powder coated Enish,3 years stainless steel'Mesh.See website for death. ,' ;c,• .
NSL vEto,Ea: 4ko F 61 riPE:t, V‘ �� '- +. 4•H 11'4� 1SFR
www mbse.:An NOTES: 1 V4�P�T
y, 1 s Pack-ef / S
Q g f 5- 7Lam1 d c%c ,
D(_PARTIV1ENT OF ENVIRONMEd I sAL PROTEC i sty'; �� I >~ s J� 4-APPROVED LIGHTING PLAN X; )-e co PI •
7.-. r., approval is limited to the exterior lights depicted rn 71
''amped plans. This approval does not relieve the eppl-
-:-r,r: ponsibility to obtain any other approvals or permits tt..-'. ,S'.[2•I-7
-171tr be required by Federal, State. County or Municipi
D Pvt4- _ i `i/3-'l I'1 _ L. 1 ( ?
_`,,Anis.{) FERiVii1 NO
\/) — ,k4. 7
e , VWrC. \5vcsk
311OGnFSS Incandescent Non-Metallic Cylinders Outdoor \A'1j6 72=E-Pt(-'k r'
Nc
11"pe f•"' "gt)
-30 -31
P5712 -
P5713
Finish Dimensions(Inches)
Catalog No. White Black Limping A 6 C D
P5712 -30 -31 1-76w PAR70,85w 01130 4-718 7.114 7-3/4 2-1/2
P6713 30 -31 2-76w PAR30 5 14 7-114 7
�--- ` OFFICE COPY
•
a
P5712 H A -_a!I 1 P5713
Specifications:
General :,k;12.Lio
•Polycarbonate construction •Medium based ceramic socket with
•Interior or exterior use nicks plated brass screw shell
•Non corrosive hardware Supplied IjrCe -rte
•P5712-Down Fighting.Shields PAR •P8799-30 or-31 top lens cover for
lamps to minimize glare and provide P5713 fixture
compliance with turtle laws(check local Waging
•P5713-up/clown lighting.P8799 top 'UL-CU.wet location listing fo•P5712
cover lens recommended when unit is and P57'3 with P8799 cover
used outdoors •UL-CUL I sting for P5713 for indoor use
Mounting
with no cover
•Wall mounted
•Covers any outlet box
•Mounting bracket is 4-112'square
Progress Lighting •Outlet box mounting bracket is supplied
701 Mirennium Blvd. Fermits attachment of unit to wall with
Greenville,South Carona one almost invisible set screw
29607
Rev 8106
w cow.p rogreswlighting.corn
TiENT OF ENVIRONMENTAL ®TECTcCr: 14i ,1
k--
APPROVED oils;� 4d/1'h
,
i. approval is limited to the exterior lights depictew
tamped plans. This approval does not relieve thi OVkeF 14 ,
��y�t.rice
the responsibility to obtain any other approvals or p ANT
may be required by Federal, State.
County or Mun:ci
REVIEWED DATE FES, ;T I`.
Incandescent Cylinders Outdoor Surface Mount - moi•
rype .
•20 -30 -31
P5741
7G1A\_ �D
Ambit Dimensions Ondms)
Catalog No. Brooms White Mak tamping A 1.0
P5741 -20 -30 •31 250PAR36,1503R40 6 12
OFFICE COPY
T
e
-o
cLeaeL Ele.t- l
•Extruded alummwn.125 rail themess •Medium base porce(am socket wish
•Ceainq or pendant mounted n.ckel plated brass screw shei
•Posder coat Bronze -20;,White(-301 or1h
Back(.31)finishes •UL-CUL damp k Caton listed
•Interior finish matches exter.ar brush
MnunLo;
•Cenitg mount
•Covers any outlet box
•Mourltog hardwa'e included
•Pendant maint
•Order pedant kit(P9741)separately
•Pendant kit,ndudes canopy,hang
sra;gnt sy.i'rel and 6"and 12"stems
with coupling
PFug•eis i.teltng
Jul Wien:-um and
G:ee .I'e,South Caroirna
23607
s•:nw OrpgressIigk rg car. Ser
DEPARTMENT OF ENVIRONMENTAL PROTECTION ✓q; ,� Y• � '
APPROVED LIGHTING PLAN 4 <0• �h..
This approval is limited to the exterior lights depicted on :.i?, 0� t ,
stamped plans. This approval does not relieve the applicant
the responsibility to obtain any other approvals or pe>snits v.
may be required by Federal, State, County or Municipal
REVIEWED DATE PERMIT NO.
w
• Model:WL-L®100 WAC LIGHTING
LEDmeatep Light Responsible Lighting'
RxtureType: 4100 , L 1•
•
Catalog Number: N1/411:113, 'O•`�
Rojecl:
Location: \47,1,WC)S
• Y-._ -12" :'rvlRvos7canob OFFICE COPY
PRODUCT 0E iFI1 4 i ,
Nodmntd rectaigle LEDmeO9ep light Oies9nedtor astdyand r4— —I J.j9. 2, Op
a1140a1140on 9einVA's patios.deck%baloonr are84walkwaRelW
tL
budding Perimeters I
Features anaditectrratdedgn Energy efficient Fon long-lasting - . - I. �.
Indoor and outdoor lighting solutions Outman attractive. it•
tanarticinpnemion a rigid front fad bark
FEATURES .—._ SPEWFICAUONS
•StUddiewa braes corrodonro99aht aluminum alloy. Construction 0wcast aluminum or 316 marine grademY 9aidesIeeI
or cast Painlaeaad consttudion Bawer Olrect wiring.no iambi driver needed Input Voltage:
•Dred wing.no driver needed 120V or 277WL weal:
•Lox proyrb.Audt to wall a teIlawtIh no viable hardware Light Source 3000(CCTSemtung lN-ACFagh Muer LED.Qi.85
•40.000 hour reed Me Optional mic:fle s Tota power commotion of 39W
•Bekerced hghttng.free of 9adowswith minimum gore Mounting Rtsinto2'•4'Atm wth minimum made dnrenndored
•11:66 rated.Protected agoing Mghgreaaaewaer lets 71,v 2•lyv 211
•L4 to 200 Nautical be connected in parallel Includes bread for Jew mount
•Flplaoeeble LED module Dimming. Dm to 10%vath etedraic low vdtage IB.V)dmrrer
•5Year V16•CUgh Mg prated waramY Approved dimmers baton NodaTNT9.V3go a 141110v600.
WtronVdriVIB.V600,heron Deva DV 03008.
Winn Skylark 5.V-300P,baton Maestro M9B.V600
Standards K86.U.6d)LDeed for wet locations
OPD6iNUMBHi
Model a Lo9h.1 Color finial
C M •
WL-u33100 • AM VV
%M-1.®100F RD • BN
et 8N
WL183100 BEM
AM
'Kited Ndd Enid,eta Interior away
_ED
Faanplo wute f00E-BL-SS
wadigluingmm HeadquarteroFa9ern Distribution Center Cent rat DOributlon Center Wbstern Distribution Cerner
Firone(800)5262588 44 Iirboc Fart Drive WOO Peri button 0 1750 Archibald Avenue
Fa, (800)5202585 AwlVNdwgton.NY 11050 labia Wing%6430122 Ontario.CA 91780
ValasaiireahensthenCii to=city thedaa3d cal:o nam any ernoaspend theowrparr1sconIWImpoenat prnCn, Aug 2016
DEPARTMENT OF ENVIRONMENTAL PROTECTION RECEIVED
APPROVED LIGHTING PLAN FEB 27 2017
This approval is limited to the exterior lights cepicted on the
stamped plans. This approval does not relieve the applicant af DIVISION OF WATER
the responsibility to obtain any other approvals or permits wh t:h RESOURCE MANAGEMENT
may be required by Federal, State, County or Municipal law.
/xt IX(
REVIEWED DATE FERMi? I .:
pv-'f'r)