340 8TH ST -POLE REPLACEMENT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW17-0004 Description: JEA- pole replacement Estimated Value: 0 Issue Date: 6/1/2017 Expiration Date: 8/30/2017 PROPERTY ADDRESS: Address: 340 8TH ST RE Number: 169928 0000 PROPERTY OWNER: Name: Alex Sifakis Address: GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JEA Address: Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. I .t-----,; ..,\.-,--i.-,-„,;., .f, Permit Conditions ,;-_: 7 .?, \-' City of Atlantic Beach . '<i,_0;09, . tvidoitritivaiT. Permit Number: ROW17-0004 Description:JEA-pole replacement Applied:5/23/2017 Approved:6/1/2017 Site Address:340 8TH ST Issued:6/1/2017 Finaled: City,State Zip Code:Atlantic Beach,Fl 32233 Status:ISSUED Applicant:<NONE> Parent Permit: Owner:Alex Sifakis Parent Project: Contractor:<NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 5/26/2017 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. 2 5/26/2017 UTILITY ROAD CUT INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the plans. 3 5/26/2017 UTILITY MAP INFORMATIONAL PUBLIC WORKS Kayle Moore Notes: See attached Utility Map. s Printed:Thursday,01 June, 2017 1 of 1 1 fjrLy ji 1• s� CITY OF ATLANTIC BEACH r 9-.•••• 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233:- INSPECTION PHONE LINE 247-5814 RIGHT OF WAY - SINGLE OR iWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW17-0004 Description: JEA- pole replacement Estimated Value: 0 Issue Date: 6/1/2017 Expiration Date: 8/30/2017 PROPERTY ADDRESS: Address: 340 8TH ST RE Number: 169928 0000 PROPERTY OWNER: Name: Alex Sifakis Address: GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JEA Address: Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. t i.Ju r, �3 � ►' ..,i Permit Conditions '4V City of Atlantic Beach Permit Number: ROW17-0004 Description:JEA-pole replacement Applied:5/23/2017 Approved:6/1/2017 Site Address: 340 8TH ST Issued:6/1/2017 Finaled: City,State Zip Code:Atlantic Beach,Fl 32233 Status:ISSUED Applicant:<NONE> Parent Permit: Owner:Alex Sifakis Parent Project: Contractor:<NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 5/26/2017 RIGHT OF WAY RESTORATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full right-of-way restoration,including sod,is required. 2 5/26/2017 UTILITY ROAD CUT INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Any utility cuts in the road must be repaired using COl Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the plans. 3 5/26/2017 UTILITY MAP INFORMATIONAL PUBLIC WORKS Kayle Moore I Notes: See attached Utility Map. Printed:Thursday,01 June,2017 1 of 1 i ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:20678 N.O.: 8003837 WO#: 24783683 CONST: 05/16/17 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 563 REO'D:NONE CELL ENGINEER: Robert Simpson N.O.: NIA ZIP CODE: NIA CUSTOMER/ SVC PHONE LOCATION: 338 8TH ST./R&R 3514W AND DROP 563 CENTER: SSSC N.O.:665-7793 I nlno STA 1, P# 338 8TH ST./ R&R 35/4W, RUN .T 2T _ - 4/OP TO STA 2. 1/0•,- t/OT 4 STA 2, P#335 8TH ST. THIS IS FOR NEW HOME BUILDS THIS GOES WITH P#2017/02884.910 4 0 0 0 324 314 310 0 0 316 324-1 324 311.1 348 344 338 325 3021 07 3�1 329 350341 330 0 .1... -- 347 0 _ _ i EAST COAST DR. 345 STA 2� - - -� `_- -11/\0-r \ /• Ill /. \-. VI I • 8TH _ _ -, '-\---- -- "�� _ _- / \ - 1 1 P P 1F .4r_. '• � 1 1 Off. 1 1/OT STA 1 1 0 Q 0 0 316 31 18 4 4 26 320 320-1 318-1 316-1 3 0 0 340 0 6 332 3 329 323 .52 348 346 342 337 335 331 327 31 353 347 0 330 0 0 i63 0 0 0 1% . 2/0P 4T ' BIRT Report Viewer Page 1 of 8 J4 CUE Reports Estimate 20678 563 TROUBLE 338 8TH Estimate DESIGN Contractor:None Number: ST./ R&R 35/4W AND Type: DROP. Estimate 1 563 TROUBLE 338 8TH By: SIMPRB Version: ST./ R&R 35/4W AND DROP. MWO#/Task: 24783683 Required 05/16/2017 Date: Oracle 8003837 Estimated 05/11/2017 Project#: On: Cost Estimate Materials JEA Contractor 1. New Material Cost(w/sales tax) $466.96 $0.00 2.Transformer Cost(w/sales tax) $0.00 $0.00 3. Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $713.60 $0.00 5. Extraordinary Costs $0.00 $0.00 )EA Overhead 6. Fringe Benefits (54.56%of lines 4& $498.16 $0.00 7) 7. Engineering Costs (Variable%of line $199.45 $0.00 4) 8. Project Equipment Costs (40%of $497.83 total equipment costs) 9. Material Handling (8.30%of lines 1 & $38.76 $0.00 2) 10. Inspection (6.84%of line 4) $0.00 11.Total Cost of Project $2,414.76 $0.00 12.Work Order Estimate(Line 11 minus $1,878.17 $0.00 line 8,9,&10) 13. Billable Equipment Depreciation $746.74 (60%of total equipment costs) 14. Billing Estimate(Including $3,697.55 $0.00 Transformer Cost) (Lines 11 + 13 + (58.71°k of 4&7)) 15. Billing Estimate(Without Transformer $3,697.55 $0.00 Cost) (Lines 11 + 13+ (58.71%of 4 &7) - Line 2) Time Estimate Crew Requirements Total Manhours 4 Man Line Crew 22.89 May 11,2017 7:25:08 AM EDT 1 / 7 http://mx7pr.corp.j ea.com/m aximo/output?_report=j ea_cue_reports.rptdesign&appname=... 5/11/2017 BIRT Report Viewer Page 2 of 8 J4 CUE Reports Estimate 20678 563 TROUBLE 338 8TH Estimate DESIGN Contractor:None Number: ST./ R&R 35/4W AND Type: DROP. Estimate 1 563 TROUBLE 338 8TH By: SIMPRB Version: ST./ R&R 35/4W AND DROP. MWO#/Task: 24783683 Required 05/16/2017 Date: Oracle 8003837 Estimated 05/11/2017 Project#: On: CU Detail Station 01 P# 338 8TH ST./ R&R 35/4W AND DROP. Build Transfer Remain in Place Remove P.35/4W 11 I G3W*2 11 I I S6 21 I I I GY3*5 11 1 C.4/0P 701 I S4*4/0 11 1 HANDDIG sI I DEEPER 21 I RUBUP 21 1 I 'RUBDOWN 2 I 1 I ICUT 2 1 1 IP.35/4W 1 1 I IWOODGRD 1 IEYENUT 2 I 'NUMBER 1 1 I IPOLECON 1 I ISMWEDGE 2 S20ES*4/0-1/0 11 1 1 1 1 1 ' I IC.1/0T 60 Station 2 P# 335 8TH ST. Build Transfer Remain in Place Remove S4*4/0 1I 1 11 11 May 11,2017 7:25:08 AM EDT 2 / 7 http://mx7pr.corp.jea.com/maximo/output?_reportjea_cue_reports.rptdesign&appname=... 5/11/2017 BIRT Report Viewer Page 3 of 8 J CUE Reports Estimate 20678 563 TROUBLE 338 STH Estimate DESIGN Contractor:None Number: ST./ R&R 35/4W AND Type: DROP. Estimate 1 563 TROUBLE 338 8TH By: SIMPRB Version: ST./ R&R 35/4W AND DROP. MWO#/Task: 24783683 Required 05/16/2017 Date: Oracle 8003837 Estimated 05/11/2017 Project#: On: CU Detail Station 2 P# 335 8TH ST. Build Transfer Remain in Place Remove S2OES"4/0-4/0 11 I I I I I RUBUP 41 I I I I I I I I I I (RUBDOWN 4 May 11,2017 7:25:08 AM EDT 3 / 7 http://mx7pr.corp.jea.comhnaximo/output?_reportjea_cue_reports.rptdesign&appname=... 5/11/2017 BIRT Report Viewer Page 4 of 8 CUE Reports Estimate 20678 563 TROUBLE 338 8TH Estimate DESIGN Contractor:None Number: ST./ R&R 35/4W AND Type: DROP. Estimate 1 563 TROUBLE 338 8TH By: SIMPRB Version: ST./ R&R 35/4W AND DROP. MWO#/Task: 24783683 Required 05/16/2017 Date: Oracle 8003837 Estimated 05/11/2017 Project#: On: Conductor, Conduit and Pipe Detail Quantities From Station To Station CU Build Transfer Remain Remove 01 2 C.4/0P 70 0 0 0 01 2 C.1/0T 0 0 0 60 May 11,2017 7:25:08 AM EDT 4 / 7 http://mx7pr.corpjea.com/maximo/output? report=jea_cue_reports.rptdesign&appname=... 5/1 1/2017 BIRT Report Viewer Page 5 of 8 JEA CUE Reports Estimate 20678 563 TROUBLE 338 8TH Estimate DESIGN Contractor:None Number: ST./ R&R 35/4W AND Type: DROP. Estimate 1 563 TROUBLE 338 8TH By: SIMPRB Version: ST./ R&R 35/4W AND DROP. MWO#/Task: 24783683 Required 05/16/2017 Date: Oracle 8003837 Estimated 05/11/2017 Project#: On: Material Summary Item Quantity Item Number Item Description 1 EACH ANCSS002 ANCHOR,SCREW,SINGLE-HELIX,GALVANIZED 10" X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 2 EACH BOLEY004 BOLT, EYE,5/8"X 14",GALVANIZED,WITH SQUARE NUT ATTACHED 1 EACH BOLMS036 BOLT,MACHINE,3/4"X 14",SQUARE HEAD GALVANIZED STEEL,W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 70 FEET CAIOS003 CABLE,4/0-19(PAP),OVERHEAD SERVICE DROP,600 VOLT MULTIPLEX CABLE "VICKSBURG"PRE-ASSEMBLED PARALLEL 1000 FOOT REELS 1 EACH CLAGROO1 CLAMP,GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 EACH CLASR002 CLAMP,STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP 1 EACH CLASR003 CLAMP,STRAIN RELIEF WEDGE MESSENGER, SIZE: #6-2/0 2 EACH CLASS006 CLAMP,STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM 3 EACH CNNCP002 CONNECTOR,#2,6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 2 EACH CNNCP006 CONNECTOR,#6, 1/0-2/0 MAIN,3/0-4/0 TAP COMPRESSION,PARALLEL TAP, ALUMINUM, 3 EACH CNNCP007 CONNECTOR, #7,3/0-4/0 MAIN,3/0-4/0 TAP COMPRESSION,PARALLEL TAP, ALUMINUM, 1 EACH CNNCP008 CONNECTOR,#5,6-2 MAIN,4/0 TAP,COMPRESSION, PARALLEL TAP,ALUMINUM, 2 EACH CNNVG003 CONNECTOR,6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 16 FEET COBC0028 CONDUCTOR,#4 SOLID,SOFT DRAWN,BARE COPPER,200',25#,ON PLASTIC REEL,4"X 11.5"W/2"HOLE 70 FEET COBCW014 CONDUCTOR,#4,TYPE 40 DSA,COPPERWELD&COPPERWELD-COPPER.204" DIAMETER 1480# BREAKING STRENGTH (50#COIL-427') 4 EACH COVIC002 COVER,"D"DIE,INSULATING,2-1/2" 1 EACH GUAGW001 GUARD,GROUND WIRE, 1/2"X 1/2"X 96",GRAY PLASTIC 1 EACH GUAGW002 GUARD,"YELLOW",GUY WIRE, 1/4"TO 1/2"8',POLYETHYLENE,USED ON ALL 3/8"AND 7/16"GUY STRANDS(DISTRIBUTION) 1 EACH GUYAT008 GUY HOOK,COMBINATION, MALLEABLE OR DUCTILE IRON,HOT DIP GALV. 13/16" MOUNTING HOLE,20,000 LB MIN.ULT.STRENGTH. FOR WOOD OR CONCRETE POLES 2 EACH GUYGROO1 GRIP,GUY,3/8",26",GALVANIZED 50 FEET GUYST005 STRAND,GUY,3/8" DIA,7 PER STRAND,GALVANIZED STEEL,CLASS"B"GALV. OR BEZINOL IS ACCEPTABLE (500'COIL) 1 EACH INSGB002 INSULATOR,STRAIN,GUY BREAKER, 21,000# RATED,60"ROD LENGTH, FIBERGLASS FOR USE ON MA'S DISTRIBUTION SYSTEM ONLY 2 EACH INSS0002 INSULATOR,SUSPENSION,4",CLASS 52-9 NEMA STRENGTH 10000#,GALV. FITTINGS http://mx7pr.corp jea.com/maximo/output?_report=jea cue_reports.rptdesign&appname=... 5/11/2017 BIRT Report Viewer Page 6 of 8 2 EACH NUTEY002 NUT,EYE, 5/8",HOT DIPPED GALVANIZED 1 EACH POLW0003 POLE,WOOD,35'CLASS 4(T/L=44),WEIGHT=1,026 LBS 1 EACH RODGR003 ROD,GROUND,THREADLESS,5/8"X 8',SHIP ON OPEN FLATBED ONLY! 1 EACH TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR "SLIDE IN"CHARACTERS)). 19.5"HIGH X 2"WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG.OF 50 EACH) 1 EACH WASRD005 WASHER,ROUND,3/4"BOLT SIZE X 2°DIAMETER,GALVANIZED, ***500 EACH PER BOX*** 5 EACH WASSF003 WASHER,SQUARE FLAT, 3"SQ X 1/4",5/8"X 3/4" BOLT SIZE,GALVANIZED 1 EACH WASSP002 WASHER,SPRING,3/4"BOLT SIZE,DOUBLE COIL HELICAL TYPE,GALVANIZED (EXTRA HEAVY DUTY) 15 EACH XXXYY000 DUMMY ID, May 11,2017 7:25:08 AM EDT 5 / 7 http://mx7pr.corp jea.com/maximo/output?_report=jea_cue_reports.rptdesign&appname=... 5/1 1/2017 BIRT Report Viewer Page 7 of 8 • JEA CUE Reports Estimate 20678 563 TROUBLE 338 8TH Estimate DESIGN Contractor:None Number: ST./ R&R 35/4W AND Type: DROP. Estimate 1 563 TROUBLE 338 8TH By: SIMPRB Version: ST./ R&R 35/4W AND DROP. MWO#/Task: 24783683 Required 05/16/2017 Date: Oracle 8003837 Estimated 05/11/2017 Project#: On: CU Summary BUILD CU Name uanti Description C.4/0P 70 4/0 AAC PAP W/4/0 AAAC NEUTRAL DEEPER 2 SET POLE DEEPER,PER FT. G3W*2 1 WOOD POLE - NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8" DOWNGUY W/8 FT SCREW ANCHOR HANDDIG 5 No Description... P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 6 LINE RUBBER INSTALLATION, PER SECT. S2OES*4/0-1/0 1 SECONDARY CONNECTION AT POLE S2OES*4/0-4/0 1 SECONDARY CONNECTION AT POLE S4*4/0 2 SECONDARY DEADEND S6 2 DOUBLE EYEBOLT REMOVE CU Name Quantity Description C.1/0T 60 1/0 TRIPLEX CUT 2 CUT POLE OR CROSSARM EYENUT 2 EYENUT REMOVAL NUMBER 1 POLE TAG REMOVAL P.35/4W 1 35 FT. CLASS 4 WOOD POLE POLECON 1 520 REMOVAL RUBDOWN 6 LINE RUBBER REMOVAL, PER SECT. SMWEDGE 2 SMALL SEC. WEDGE CLAMP REMOVAL WOODGRD 1 WOOD POLE NON EQUIP.GRD REMOVAL May 11,2017 7:25:08 AM EDT 6 / 7 http://mx7pr.corp.jea.com/maximo/output?_report=jea_cue_reports.rptdesign&appname=... 5/11/2017 � r'" CITY OF ATLANTIC BEACH — m\ CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS Emu cr, . par _ 800 Seminole Road 904-247-5800 Atlantic Beach,Florida 32233-5445 Fax 904-247-5845 PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION. Date ail I I n `tri/ -] PERMIT# TZG W «— voce Job Address_ 3 t-/0 Si ISSUED BY THE CITY Permitee: TI 4 Telephone# Permittee Address: Z1 14/Pn a)cra Requesting Permission to Construct: p/Ck .e (i ) 34—kr 4,,)cci f i,.i IN Pep IE,,G &// Location: (Reference to Cross-Street) E031- (oa G f J7/' 1. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Yes( ) No ( ) Date: Bell South Telephone Company Yes( ) No ( ) Date: Ferrell Gas Yes( ) No ( ) Date: Comcast Yes( ) No ( ) Date: 2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach oc Florida Department of Transportation Standards and be performed under the supervision of ( , (Contractor's Project Superintendent)located at Zt (Ai. (14u/el, St J F,,x Telephone#: Goc-7)53 4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with 60 days. If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again immediately upon completion. OWNER Signed: Date: Before me this day of in the County of Duval, State Of Florida,has personally appeared Notary Public at Large,State of Florida,County of Duval. My commission expires: Personally Known: Produced Identification: