1158 ocean blvd - interior remodel drawingsI DESIGN SPECIFICATIONS DESIGN CODE: 2014 FLORIDA BUILDING CODE — RESIDENTIAL LEVEL II ALTERATION DESIGN IS VOID ONE YEAR AFTER THE DATE OF THE ORIGINAL PLANS, UNLESS PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE. DESIGN LOADS: ACTUAL AND UNIFORM ROOF FLOOR ROOF LOADING (cd=1.25) (cd=1.00) TOP CHORD LIVE LOAD 20 psf 40 psf TOP CHORD DEAD LOAD 7 psf (ARCH SHINGLES) 10 psf BOTTOM CHORD LIVE LOAD 10 psf 0 psf BOTTOM CHORD DEAD LOAD 5 psf 5 psf COMPONENTS & CLADDING ALLOWABLE DESIGN PRESSURES DEFLECTION CRITERIA: ROOF FRAMING: LIVE LOAD FLOOR FRAMING: LIVE LOAD L/240 TOTAL LOAD L/180 L/360 & TOTAL LOAD L/240 EDGE STRIP (PSF): ZONE (PSF) WIND LOADING: 10 +18.2 —19.8 +18.2 —24.4 ASCE 7/10 +16.3 —17.9 +16.3 —20.6 100 BASIC WIND SPEED (ASCE 7-10) -------------- 130 MPH IMPORTANCE FACTOR — — — — — — — — — — — — — — — — — — — — — — 1.00 MEAN ROOF HEIGHT ----------------------- 15.0 FT ROOF PITCH — — — — — — — — — — — — — — — — — — — — — — — — — — — — EXISTING BUILDING CATEGORY ----------------------- II EXPOSURE CATEGORY — — — — — — — — — — — — — — — — — — — — — — B ENCLOSURE CLASSIFICATION -----------------ENCLOSED INTERNAL PRESSURE COEFFICIENT -------------- f .18 COMPONENTS & CLADDING ALLOWABLE DESIGN PRESSURES TRIBUTARY AREA (sf) INTERIOR EDGE STRIP (PSF): ZONE (PSF) 'a' = 4'-6" 10 +18.2 —19.8 +18.2 —24.4 50 +16.3 —17.9 +16.3 —20.6 100 +15.5 —17.0 +15.5 —19.0 • THE VALUES ABOVE ARE ALLOWABLE WIND PRESSURE VALUES (ASD). THE ABOVE WIND PRESSURES HAVE BEEN REDUCE BY 0.60 AS PERMITTED BY THE ALLOWABLE STRESS DESIGN METHODOLOGY. NO FURTHER REDUCTION SHALL BE PERMITTED • COMPONENT & CLADDING WALL ELEMENTS SHALL BE DESIGNED FOR BOTH POSITIVE AND NEGATIVE PRESSURES SHOWN IN TABLE ABOVE. • LINEAR INTERPOLATION IS PERMISSIBLE. • PLUS = PRESSURE AND MINUS = SUCTION. • DESIGN OF WINDOWS/DOORS FASTENING TO THE WALL FRAMING IS THE RESPONSIBILITY OF THE WINDOW/DOOR MANUF./SUPPLIER & SHALL MEET THE ABOVE NOTED POSITIVE AND NEGATIVE PRESSURES. SCOPE OF SERVICE MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE FOR ANY OF THEM TO CONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. LIMITS OF STRUCTURAL ENGINEERING DESIGN RESPONSIBILITIES: THE ITEMS SPECIFICALLY DESIGNED BY THE STRUCTURAL ENGINEER ARE LIMITED TO BEAM AND TRUSS REPAIR DIRECTLY SUPPORTING ROOF FRAMING SHOWN ON PLAN. ITEMS NOT DESIGNED INCLUDE WATER/WEATHERPROOFING, PRE—ENGINEERED WOOD FLOOR AND ROOF TRUSSES, FLOOR FRAMING NOT SPECIFICALLY INDICATED, TRUSS—TO—TRUSS CONNECTIONS, ARCHITECTURAL EMBELLISHMENTS NOT SPECIFICALLY INDICATED (EYEBROWS, CORNICE, CORNICE RETURNS, PROJECTIONS, ETC) AND ANY OTHER ARCHITECTURAL, MECHANICAL OR ELECTRICAL SYSTEM. INFORMATION SHOWN ON THESE DRAWINGS REGARDING EXISTING CONDITIONS HAVE BEEN OBTAINED BASED ON AVAILABLE SOURCES AT THE TIME OF DESIGN INCLUDING ASSUMPTIONS BASED ON EXPERIENCE WITH SIMILAR STRUCTURES. THE ACTUAL AS—BUILT CONDITION FOUND IN THE FIELD MAY VARY FROM INFORMATION INDICATED IN THESE DRAWINGS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY ENGINEER IN WRITING BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN THESE DRAWINGS AND/OR ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL REPAIR/REPLACE ANY DAMAGED EXISTING STRUCTURAL MEMBERS DISCOVERED DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING CONSTRUCTION. SAFETY OF THE STRUCTURE AND PERSONNEL DURING CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. NEW (3)2x4 SPF#2 POST. CONTRACTOR TO VERIFY POST SITS DIRECTLY ON BEAM AND WITHIN 8" MAX. OF OFFGRADE PIERS. IF CONDITIONS NOT MET, ADD PIER/FOOTING ETAIL,*/.0. EXISTING CEILING I,' TO REMAIN w/LUS26 ( NEW (3)2 SPF#2 POST. CONTRACTOR TO POST SITS DIRECTLY ON BEAM AND WI MAX. 1F OFFGRADE PIERS. IF CONDITIO MET ADD PIER/FOOTING PER DETAIL NEW (3)2x4 SPF#2ST. 0 AC R ,TO RIFY POST SITS DIRE A 8" MAX. OF OFFGRA S N T MET, ADD PIER DOTING PE JD ISIQ EXISTING ICEILING JOISTS TO REMAIN. HANG w LUS26 (TYP.). c`4 III Q III (/) m III N RIFY N m U) ..� v III f 117 3: w 2.0 NEW (3)2x12 SYP#2 L' III RECESSED BEAM J L JILL JIIL JIIL J�L J L J L 1 r - r r r �11•r r r III NEW HUS210-3 III HANGER. r NE (3)2x4 SYP #2 POST. STRAP BEAM To POST w/ 2—CS16. CONTRACTOR TO VERIFY POST SITS DIRECTLY OVER STEMWALL w/ GROUT FILLED CELLS. N NEW 2—PLY 11.25" LVL RECESSED BEAM II�SEE DETAIL 3/ S2.0. r VJ 1 W/ L—L'o I U. VUIV I r\M%- 1 Vr, VERIFY POST SITS DIRECTLY OVER -EMWALL w/ GROUT FILLED CELLS. CONTRACTOR SHALL ADD NEW 2x6 SYP#2 FLOOR JOISTS BETWEEN EACH EXISTING JOIST SO THE SPACING IS 12" O.C. MAX. NEW FRAMING PLAN SCALE: 1/4" = 1'-0" (2)2x8-1 /2 SON LTT20B FASTENED w/ Y2"Ox6" TITEN HD. SIMPSON LTT20B FASTENED w/ rY2"Ox6" TITEN HD. STRAP HEADER PER DETAIL 1/S2.0. EXISTING CEILING JOISTS TO REMAIN. HANG w/LUS26 (TYP.). NEW (2)2x8 SYP#2 RAISED HEADER. EXISTING FOUNDATION TO REMAIN AS IS. I II '! j NEW 2x8 SYP#2 LEDGER FASTENED BELOW EXISTING JOIST DIRECTLY TO WALL STUDS w/ Y4"x4" SDS SCREWS 16" O.C. CONTRACTOR VERIFY EXISTING STUDS ARE SPACED ® 16" O.C. MAX. II I NEW NON—LOAD BEARING WALL. EXISTING JOIST TO REMAIN AS IS. OFFICE COPY REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS REVIEWED BY: DATE: 6� Associates, Inc. 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 �4 `�':.� ...arc(/ -,1,,,,, � Na. r)F o o f'irf N�vE`' Luis A. Pontigo, PE FL PE#53311 REVISIONS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO & ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS VMCH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS. ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO & ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. w U Z J w�LL Lf) I U Uj Q/mQ Z LIJ � w U QOZ �ooQ 0Ln Q 2 DESIGN CRITERIA, GENERAL NOTES AND NEW BEAM FRAMING PLAN DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT THE EO.R AN NAME SHADILLL KER RENOVATION DESIGN/DRAWN/CH ECKED CS JB LAP DATE 05.05.17 SCALE AS NOTED LPA No. PTDA-17-00358 CONTROL No. SHEET SID SHEET 1 OF 2 2—SIMPSON H2.E STRAP KING F POST BELOW WITH STRAPS WHEN FULL HtiuH I ANCHORS ARE NOT USED 0 NG POST TO ., NITH 2—CS16 STRAPS WHEN FULL HEIGHT ANCHORS ARE NOT USED HEADER DOWN CONNECTION CONNECTION UPLIFT CONNECTOR CALL OUT A H2.5T ® 32" O.C. TOP & BOT B SEE PLAN C (1)MSTA24 STRAPS D FULL HGT THREADED ROD SEE PLAN OR HTT4 HOLD DOWN AT BASE FULL HGT THREADED ROD SEE OR HTT4 HOLD DOWN AT BA OR 2—CS16 TO BEAM BELOW (U.O.N) HEADER TIE DOWN THIS DETAIL ONLY APPLIES WHEN NOTED ON PLAN 2—CS16 FROM NEW POST TO EXISTING OFF GRADE BEAM. EXISTING FLOOR SYSTEM 4x4 SYP#2 P.T. STUB POST. FASTEN TO NEW BEAM w/(2) MTS12 SECTION SCALE: 3/4" = 1'-0" POST, SEE PLAN 2x_ SYP#2 SQUASH BLOCKS FIT TIGHT BELOW NEW POST ABOVE EXISTING OFF GRADE BEAM ABU44 w/ Y2"x6" TITEN HD 16"x16" ' --- 2—#5 EA. DIRECTION 0 Aw L 11 HEADER UP CONNECTION CONNECTION CALL OUT UPLIFT CONNECTOR A LS18 @ 32" O.C. B SEE PLAN C (2)CS16 STRAPS D FULL HGT THREADED ROD SEE OR HTT4 HOLD DOWN AT BA PLAN 3E (U.O.N) d v Q 16"x16" ' --- 2—#5 EA. DIRECTION 0 Aw L 11 HEADER UP CONNECTION CONNECTION CALL OUT UPLIFT CONNECTOR A LS18 @ 32" O.C. B SEE PLAN C (2)CS16 STRAPS D FULL HGT THREADED ROD SEE OR HTT4 HOLD DOWN AT BA PLAN 3E (U.O.N) 2 PLY BEAM. 3 PLY BEAM. LJL (4) ROWS 12d CL 0 - AT 12" O.C. EA. SIDE. (3) ROW 12d AT 12" O.C. EA. SIDE. 2 & 3 PLY BEAMS 2 S2. 2 2x4 MEMBERS: (1) ROW OF 1 Od NAILS @ 4" O.C. 2x6 MEMBERS: (2) ROW OF 1 O NAILS @ 4" O.C. STAGGERED 2x4 OR 2x6 POST N OTES: 1. TYP. CONNECTION AT STUD COLUMNS, JACK—TO—KING ASSEMBLIES, CORNER POST, ETC. 2. SPECIFIED NAILING REQUIRED FOR EVERY PLY IN ADDITION TO (2) PLYS BUILT-UP MEMBER FASTENING EXISTING JOIST T REMAIN (TYP.). NEW BEAM PLAN. LU S26 HANGER (TYP.). NEW BEAM TO CEILING JOIST CONNECTION OFFICE COPY Lou Pontigo and Associates, Inc. 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 POi r N , No. 11 s = c ,,�•; S OF o '�1f?lilUUliMI��`' Luis A. Pontigo, PE FL PE#53311 REVISIONS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO & ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS. ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO & ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING DR INSPECTION FEES. W U Z J w�� 406 J U � mZ LLJ w � w U QOZ 00 Q�Q 2 (f) DESIGN CRITERIA, GENERAL NOTES AND NEW BEAM FRAMING PLAN DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT THE E.O.R PLAN NAME SHAD/WALKER RENOVATION DESIGN/DRAWN/CHECKED CS JB LAP DATE 05.05.17 SCALE AS NOTED LPA No. PTDA-17-00358 CONTROL No. SHEET S2,0 SHEET 2 OF 2