1345 SEMINOLE RD - WINDOW S r,y r j' \s f CITY OF ATLANTIC BEACH �' 800 SEMINOLE ROAD �� s \ �� 9''' ATLANTIC BEACH, FL 32233 'o;i� INSPECTION PHONE LINE 247-5814 RESIDENTIAL - ALTERATION RESIDENTIAL MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0066 Description: WINDOW REPLACEMENT & SIDING REPAIR Estimated Value: 15000 Issue Date: 6/26/2017 Expiration Date: 12/23/2017 PROPERTY ADDRESS: Address: 1345 SEMINOLE RD RE Number: 171897 0000 PROPERTY OWNER: Name: SMITH DEAN S Address: 1345 SEMINOLE RD ATLANTIC BEACH, FL 32233-5508 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: Address: , Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) i 800 Seminole Road / Atlantic Beach, Florida 32233-5445 1 E- 7 0 (0.6 y Phone(904)247-5826 Fax(904)247-5845 / >>` E-mail: building-dept@coab.us Date routed: h3�l(-L2 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1545 SErnt1O0 RD Department review required Yes o uildin Applicant: (�1� Manning &Zoning '' Tree Administrator Project: G ( xpoo (A.) RePCA-C_P- - Public Works Public Utilities • S ( D( lO(\ 1. EPA(2_ Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date Florida Dept.of Environmental Protection Florida Dept. of Transportation of Permit Verified By St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. (Denied. . I 1Not applicable (Circle one.) Comments: ILDING PLANNING &ZONING Date: G ad•c-) Reviewed by: TREE ADMIN. Second Review: Approved as revised. I 1Denied. . Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. I IDenied. . Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ' Building Permit Application City of Atlantic Beach OFFICE COPY 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (904) 247-5845 /� Job Address: 13-45 S SMI uoc - RD• Permit Number: 26S h — 006C Legal Description a-''i Ile—2.5 Zq sgb/4 MAQ(J1A Lt.M.(7 I RE# 171 `bbl •7-000c, Valuation of Work(Replacement Cost)$ )� t 0 3 Heated/Cooled SF — Non-Heated/Cooled • Class of Work(Circle one): New Addition Alteration epa' Move Demo Pool indow/Door • Use of existing/proposed structure(s)(Circle one): Commercial ,Residentiaa • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes ,S0 N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: ' j t nlw� ( E PG.nC S(D 11.16- L1gPA t( Florida Product Approval# 13 1I.3. C for multiple products use product approval form Property Owner Information Name: 1 Sf-/.•.l( E 4' 1-)Lca!\ Address: 1345 SEhk( iJ GL- City i71L-2 VT LG'! 13- a State-L. Zip 32 2 33 Phone 1041----- E-Mail al�� RN 1-rt i <<� rym cc r(A4f < C '1Y—A Owner or Age (If Agent, Power of Attorney or Agency Letter Requi Contractor Information Name of Company: Qualifying : t: Address City State Zip Office Phone Job Site/ • act Number State Certification/Registration# E-M•• Architect Name& Phone# Engineer's Name& Phone# Workers Compensation _ Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTIC OFC MMENCEMENT. ature of wner or Agent including Contractor) (Signatu • of Contractor) Signed a d swo • o(or affirmed) before me this ;day of Signed and sworn to (or a• rmed)before me this day of , avl ,by �� _� ,. �. by � cf ANGELA M(I"FAT of Notary) (Signature of Notary) : MY COMMISSION U FF24140.. .ft.t EXPIRES June 17,2019 ' (407)3V-0'S3 F InnallowyService.con. [ ]Personally Known OR [ I Personally Known OR [-,]Produced Identification [ ]Produced Identification Type of Identification: L,v.1 - 2 71-0 Type of Identification: 6 _. C�I"FICECC � i I ' - ';'' 1 i Kw". \now 1 .....7.... .. ,:4_,.. L___ ._ 1 I ' a3 � suss i il l , • --- • --,- Ail 1 . . ;� --- _o � : �_ 1 t i . r �� EXISTING al ,: • ` �- L FENCE sar7 Th- LIIIc1L _ . ; #1345 . .. j 3 li Wall "b [._. • '`.: EXISTING RESIDENCE EXI , NG rFENC I 1 • Z 7 - Z ° .-i MATERIAL ; Y ce 0— STORAGE � ce - g--.i ` OTE : _ .�-- �- � cN ! ! NO CHANGE TO EXISTING w f IMPERVIOUS AREA I NO EXCAVATION ` I NO TREE REMOVAL A I o iPROPS TY LINE PROP:•1Y LINE �+_ LOT AREA 20,908 IMPERVIOUS AREA 3,748 LOT COVERAGE 18% 6-2-2017 ITE MANAGEMENT PLAN SMITH RESIDENCE S 1345 SEMINOLE RD ATLANTIC BEACH FL „,-.7c---,-,/,./, OFFICE COPY a _ CITY OF ATLANTIC BEACH � � '�%,' WNER / BUILDER AFFIDAVIT I. FLORIDA STATUTES; CHAPTER 489, FLORIDA STATUTES, PART 1 "CONSTRUCTION CONTRACTING”REQUIRES OWNER/BUILDER TO ACKNOWLEDGE THE LAW: DISCLOSURE STATEMENT FOR SECTION 489.103(7),FLORIDA STATUTES: STATE LAW REQUIRES CONSTRUCTION TO BE DONE BY LICENSED CONTRACTORS. YOU HAVE APPLIED FOR A PERMIT UNDER AN EXEMPTION TO THAT LAW. THE EXEMPTION ALLOWS YOU,AS THE OWNER OF YOUR PROPERTY,TO ACT AS YOUR OWN CONTRACTOR EVEN THOUGH YOU DO NOT HAVE A LICENSE. YOU MUST SUPERVISE THE CONSTRUCTION YOURSELF. YOU MAY BUILD OR IMPROVE A ONE—OR TWO FAMILY RESIDENCE OR A FARM OUTBUILDING. YOU MAY ALSO BUILD OR IMPROVE A COMMERCIAL BUILDING AT A COST OF$25,000.00 OR LESS. THE BUILDING MUST BE FOR YOUR USE AND OCCUPANCY. IT MAY NOT BE BUILT FOR SALE OR LEASE. IF YOU SELL OR LEASE A BUILDING YOU HAVE BUILT YOURSELF WITHIN ONE YEAR AFTER THE CONSTRUCTION IS COMPLETE,THE LAW WILL PRESUME THAT YOU BUILT IT FOR SALE OR LEASE, WHICH IS IN VIOLATION OF THIS EXEMPTION. YOU MAY NOT HIRE AN UNLICENSED PERSON AS YOUR CONTRACTOR. YOUR CONSTRUCTION MUST BE DONE ACCORDING TO THE BUILDING CODES AND ZONING REGULATIONS. IT IS YOUR RESPONSIBILITY TO MAKE SURE THAT PEOPLE EMPLOYED BY YOU HAVE LICENSES REQUIRED BY STATE LAW AND BY COUNTY OR MUNICIPAL LICENSING ORDINANCES. II. INJURY LIABILITY; SINCE OWNERS MAY BE LIABLE FOR INJURIES TO WORKERS THEY HIRE, THE BUILDING DEPARTMENT SUGGESTS WORKER'S COMPENSATION INSURANCE BE PURCHASED. III. IRS WITHHOLDING; OWNERS HIRING WORKERS BECOME EMPLOYERS AND SHOULD ALSO OBSERVE IRS WITHHOLDING TAX AND/OR FORM 1099 REQUIREMENTS ON THE WORKERS THEY EMPLOY ON THEIR IMPROVEMENT TRADES. IV. PENALTY; UNLICENSED CONTRACTORS CANNOT BE EMPLOYED UNDER ANY CIRCUMSTANCES. OWNERS BEING SUBJECT TO $5,000 PENALTY UNDER FLORIDA STATUTE NO. 455-228(1). AN "OCCUPATIONAL LICENSE"IS NOT ADEQUATE. THE OWNER SHOULD PHYSICALLY SEE THE COUNTY "CERTIFICATE OF COMPETENCY" OR THE FLORIDA "CONTRACTORS CERTIFICATE" TO ASCERTAIN IF A PERSON IS A LICENSED CONTRACTOR. TELEPHONE THE BUILDING DEPARTMENT(247-5826)IF IN DOUBT. V.ACKNOWLEDGEMENT; I HEREBY ACKNOWLEDGE THAT I HAVE READ THE ABOVE DISCLOSURE STATEMENT AND THAT I COMPLY WITH ALL THE REQUIREMENTS FOR THE ISSUANCE OF AN OWNER-BUILDER PERMIT. J35 5 l r-t O C- PJ . 10A1-_-w ---i s 1 6 ADDRESS C PHONE NUMBER iX� St••A PRINT NAME J� � SIGN RE , J DATE 15/ 11 Before me is 14 day of J Ln e- ,20_,L')in the county of Duval,State of Florida,has personally appeared herin by himself/herself and affirms that all statements and declarations are true and accurate. Notary Public at Large,State of Flo,:.1..,County of 0.,e.a;t �❑y Personally Known /� `1 ILJ Produced Identification- Fe-D ��'J �J- _7 b-f-57- -1)_p „ ;''',.:`'`: ANGELA M LYOMS .•v . COMMISSION 4 FF �' Nl Y '-a�•,,, 24 i 404 Notary Signature: �?—y�. Qom, � --1.-01-A-- ?F nr EXPIRES June 17, W07)39�-0'S3 2019 fbrutallotarySmice eon' F:/BLDG/Owner-Builder Affadavit;REVISED:4/16/2009 OFFICE COPY Jan and Dean Smith TRANSMITTAL 1345 Seminole Road Atlantic Beach, FL 32233 TEL: (904)708-7596 EMAIL: jsmith@smithmccrary.com TO: City of Atlantic Beach, FL DATE: 6/16/17 Building and Zoning Department 800 Seminole Road RE: Window Replacement at Smith Residence Atlantic Beach, FL 32233 1345 Seminole Road Atlantic Beach, FL 32233 We transmit: For your: (x) herewith ( ) approval ( ) under separate cover () review&comment (X) use Via: Hand delivery by Jan Smith The following: ITEM COPIES 1. Building Permit Application 1 2. Notice of Commencement 1 3. Owner/ Builder Affidavit 1 4. Tree and Vegetation Affidavit 1 5. Product Approval Information Sheet 2 6. Site Management Plan 2 7. Installation Instructions 2 8. Elevations of Residence 2 46. By: /t- / !� Page 1 of 1 TREE & VEGETATION AFFIDAVIT , City of Atlantic Beach OFFICE COPY i Department of Community Development Planning&Zoning Division 800 Seminole Road Atlantic Beach, FL 32233 (P) 904 247-5800 (F) 904 247-5845 PERMIT# SECTION I-APPLICANT INFORMATION Owner(s) r- Legal Authorized Agent* NAME OF APPLICANT -..,+A le\A SKIT H NAME OF COMPANY NV ADDRESS OF COMPANY I /A PHONE J CELL EMAIL CONTRACTOR CERTIFICATION NUMBER ATLBCH BUSINESS TAX RECEIPT NUMBER SECTION II-SITE INFORMATION STREET ADDRESS OF PROPERTY 131,5 S E M If an address has not been assigned to this property,contact the AB Building Department at(904)247-5826 to request an address. LEGAL DESCRIPTION 23 4 1(0 -as - Z9 s VA M (Z(N A 4-l14 (7 1 LOT BLOCK SUBDIVISION REAL ESTATE NUMBER 1 `7 10417_000,7 LOT OR PARCEL SIZE: . D/-4-n gSQ FT AC RESIDENTIAL X COMMERCIAL OTHER(SPECIFY) .11111 AIM 1 affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation" of the Municipal Code of Ordinances for the City of Atlantic Beach, FL and/or I have participated in a pre-application meeting with the Administrator of those regulations. Subsequently, I affirm that no regulated trees and no regulated vegetation will be damaged, destroyed and/or removed from the above-described oA adjacen ope 'es in conjunction with this project. S . IATURE 44F OWNER SIGNATURE OF OWNER igned and sworn before me on this t, day of by State of )6,-\ , County of , Identification verified: L{0% - 07,7-�.�( ,v Oath sworn: [ Yes E No ANGELA M LY;:;1e:, w MY COMMISSION It FFi4 1404 Notary Signature iP;, EXPIRES Jure 17,2019 11407)39°,0'53 FioroANo;a•y9m:-,1 My Commission expires: ° Icl rcty-1 v11.12 • J�,� OFFICE COPY 0 TI. 13223. 7_ Florida Product Approval HardiePanel® Siding • For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 15- 0122.04. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Report RIO-2556-15. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. • • HardiePaneI®IiZL . JamesHardie Vertical Siding EFFECTIVE SEPTEMBER 2013 INSTALLATION REQUIREMENTS RESIDENTIAL SINGLE FAMILY ONLY-PRIMED&COLORPLUSS PRODUCTS Visit www.jameshardie.com for the most recent version. SMOOTH • CEDARMILL© SELECT SIERRA 8 • STUCCO IMPORTANT:FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE,VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY.BEFORE INSTALLATION,CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ10T"PRODUCTS OUTSIDE AN HZ10®LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION,VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343(866 9HARDIE) STORAGE& HANDLING: Z . CUTTING INSTRUCTIONS Store flat and keep dry and OUTDOORS INDOORS covered prior to installation.Installing 1.Position curing station so that with wit blow dust away tram user 1.Cut only using score and snap,or shears(manual,electric or pneumatic). and others in working area 2.Position cutting station in well-ventilated area siding wet or saturated may result in 2.use one of the following methods: shrinkage at butt joints.Carry planks a.Best: i.Saxe and snap on edge. Protect edges and corners ii.Shears(manual,electric or pneumatic) -NEVER use a power saw indoors from breakage.James Hardie isnot b.Better: i.Dust reducing circular saw equipped with a -NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark 9 HardieBlade'saw blade and I-EPA vacuum extraction -NEVER dry sweep–Use wet suppression or HEPA Vacuum responsible for damage caused c.Good: i.Dust reducing circular saw with a Hardietlade saw blade by improper storage and handling of lofty use to lav to moderate cutting) the product. Important Note:For maximum protection(lowest resprable dust prodiction),James Hardie recommends always using"Best"-level cutting methods where feasible. `w' NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures.Additional engasre information is available illiat www.jamestlardie.ceml to help you determine the most appropriate cutting method for your job requirements.If concern sill exists about e�ostre levels a you -__ do not comply vett the above practices,you should always consult a qualified industr al hygienist mist or contact James Hardie for further information. Baa,r GENERAL REQUIREMENTS: I • These instructions to be used for residential single family installations only.For Commercial/Multi-Family installation requirements go to www.JamesHardieCommercial.com • HardiePanel'vertical siding can be instated over braced wood or steel studs spaced a maximum of 24"o.c.See genemal fastening requirements.Irregularities in framing and sheathing can mirror through the finished application.James Hardie recommends instating HardiePanel on a capillary break(rainscreerl/funing)as a best practice. • Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www.jamehardie.com • A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration.James Hardie does manufacture HardieWrap®Weather Barrier,a non-woven non-perforated housewrapl,which complies with building code requirements. • When installing James Hardie products all clearance details in figs.5.6,7,8,9,10&11 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building codes-typically a minimum of 6"in the first 10'. • Do not install James Hardie products,such that they may remain in contact with standing water. • HardiePanel vertical siding may be installed on vertical wall applications only. • DO NOT use HardiePanel vertical siding in Fascia or Trim applications. • Some application are not suitable for ColorPlus.Refer to ColorPlus section page 3. • DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie®Products. • For larger projects,including commercial and multi-family projects,where the span of the wall is significant in length,the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design.These values can be found in the Technical Bulletin #8"Expansion Characteristics"at www.JamesHardie.com. INSTALLATION: Joint Treatment Fastener Requirements • Vertical Joints-Install panels in moderate contact(fig.1),alternatively Position fasteners 3/8"from panel edges and no closer than 2"away from corners.Do not nail into corners. joints may also be covered with battens,PVC or metal jointers or HardiePanel Vertical SidingInstallation caulked(Not applicable to ColorPlus'Finish)(fig.2). • Horizontal Joints • Framing must be provided at horizontal and vertical edges for nailing. Provide Z-flashing at all horizontal joints(fig.3). • HardiePanel vertical siding must be joined on stud. Figure 2 Figure 3 water-resistive barrier water-resistive bather • Double stud may be required to maintain minimum edgex4�� water-restive water-restive nailing distances. (�� i/ l'411021...... 2 x 4 stud barrier barrier Figure 1 7 0 .—upperpanel .--upperpanel stud` t t: Do not 1/4"gap Do not 1/4'gap water-resistive / I Caulk Caulk barrier — ' -"A?"' -`� ;t _ i ♦ a �%'',�— " " ~Z-flashin 4-Z-flashicg sheathing HardiePanel Batten Joint H Joint l 9 I r (0 ci vertical siding water-resistive bather I I decorative keep nails /l 2 x 4 stud t_lower lower band board 3/8"min. I panel I f— fromepanel • O ■ panel 9 plate - - 0 oI PI) .� Figure 4 es II - • r f leave appropriate gap between Recommendation:When •-- r� i nor• 3/8' ( panels.then caulk' lip'installing sierra B,provide. moderate cordact Caulk Joint a double stud at panel(Not applicable to CdorPlus"Knish) idnts to avoid nailing keep fasteners 2' �_— 'Apply caulk in accordance with caulk through grooves. I away from corners manufacturer's written application instructions. For additional information on HardieWrapnM Weather Barrier,consult James Hardie at 1-866-4Hardie or www.hardiewrap.com WARNING:AVOID BREATHING SILICA DUST James Ha-die products contain respirable crystalline silca,which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabicg and potentially fatal lung disease called silicosis.and has been linked with other diseases.Sane studies suggest smoking may increase these asks. During installation or handling:(1)work in outdoor areas with ample ventilation;121 use fiber cement shears for cutting or.where not feasible,use a HardieBlade saw blade and dcst-reducng circular saw attached to a HEPA vacuum: (3)warn others in the immediate area:(4)wear a properly-fated.MOSH-approved dust mask or respirator:le.g.N-951 in accordance with applicable government regulations and manufacturer instructions to further Emit respirable silica exposures. During clean-up.use HEPA vacuums or wet cleanup methods-never dry sweep. For further information.refer to err installation instructions and Material Safety Data Sheet available at MAN jameshardie.can or by calling I-800.9HARDIE(1.800.942.7343). FAILURE TO ADHERE TO OUR WARNINGS.MSDS,AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. HS1236-P1/3 1/13 ,ii . CLEARANCES Install siding and trim products in Maintain a minimum 1" Maintain a minimum 1"-2"clearance At the juncture of the roof and vertical Maintain a 1/4" compliance with local building code -2"clearance between between James Hardie products surfaces,flashing and counterflashing clearance between requirements for clearance between James Hardier and decking material. shall be installed per the roofing the bottom of James q manufacturer's instructions.Provide a Hardie products and the bottom edge of the siding and products and paths, Figure 7 minimum 1"-2"clearance between horizontal flashing. the adjacent finished grade. steps and driveways. il' the roofing and the bottom edge of the Do not caulk gap. s [_.water siding and trim. Refer to fig.3 on Figure 5 Figure 6 �d"'� resistive g �► barrier Figure 8 page 1. siding Nil _ Epp „%i•-7 mn. deck material '� i.. 1' 2'Min t”-2' min l II f • 411 Plate . la`. ashing ` „.bottom \ . ledger 6'min. I foundation Do not bridge floors with HardiePanel'siding.Horizontal KICKOUT FLASHING joints should always be created between floors(fig.10). Water- Because of the volume of water that can pour down a sloped Resistive l roof,one of the most critical flashing details occurs where a Maintain a minimum 1"gap Ramer It'` `�j Framing roof intersects a sidewall. The roof must be flashed with step between gutter end caps and Figure 10 �� / JJJ siding&trim. Horizontal F000rHhg flashing. Where the roof terminates,install a kickout to deflect Figure 9 Trim find water away from the siding.It is best to install a self-adhering – E � membrane on the wall before the subfascia and tnm boards `i. f�l► �� are nailed in place,and then come back to install the kickout. Figure 11,Kickout Flashing To prevent water from siding —� dumping behind the siding and the end of the roof sheathing intersection,install a"kickout"as required by IRC code R905.2.8.3:"...flashin shall be a min.of 4"hi h and 4" ti IIMI �i' ` fafin lirHa diePanel• wide."James Hardie recommends the kickout be angled 1 between 100°-110°to maximize water deflection gutter and end cap Figure 1� BLOCKED PENETRATIONS sop flash-.. / ,,, -s I Penetrations such as hose bibs and holes 1 /"or larger such as dryer vents /•` •' � should have a block of trim around point of penetration. `! - men�rane GENERAL FASTENING REQUIREMENTS flash �� nckoul Fasteners must be corrosion resistant,galvanized,or stainless steel.Electro-galvanized are "° acceptable but may exhibit premature corrosion.James Hardie recommends the use of quality, 1 Orin edge hot-dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie products near Housewran the ocean,large bodies of water,or in very humid climates. • Consult applicable product evaluation or listing for correct fastener type and placement to achieve specific design wind loads. • NOTE:Published wind loads may not be applicable to all areas where Local Building Codes have PNEUMATIC FASTENING specific jurisdiction.Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. James Hardie products can be hand nailed or fastened with a • Drive fasteners perpendicular to siding and framing. pneumatic tool.Pneumatic fastening is highly recommended. • Fastener heads should fit snug against siding(no air space).(fig.A) Set air pressure so that the fastener is driven snug with the 111 • Do not over-drive nail heads or drive nails at an angle. surface of the siding.A flush mount attachment on the • If nail is countersunk,fill nail hole and add a nail.(fig.B) pneumatic tool is recommended. This will help control the • For wood framing,under driven nails should be hit flush to the plank with a hammer(for steel depth the nail is driven.If setting the nail depth proves difficult, 11 framing,remove and replace nail). choose a setting that under drives the nail.(Drive under driven • NOTE:Whenever a structural member is present,HardiePlank should be fastened with even nails snug with a smooth faced hammer-Does not apply for spacing to the structural member.The tables allowing direct to OSB orplywood should only be installation to steel framing). used when traditional framing is not available. • Do not use aluminum fasteners,staples,or clipped head nails. Snug Flush elk Countersunk, n �T fill&add nail eC do not u 1.►nder DO NOT Figure A Figure B drive nails STAPLE HS1236-P2/3 8/13 a Ii !o. CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS,Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions.Note:OSI Quad as well as some other caulking manufacturers do not allow tooling. DO NOT caulk nail heads when using ColorPlus products,refer to the ColorPlus touch-up section CUT EDGE TREATMENT PAINTING Caulk,paint or prime all field cut edges. I DO NOT use stain,oiValkyd base paint,or powder coating on James HardieProducts.James Hardie products James Hardie touch-up kits are required must be painted within 180 days for primed product and 90 days for unprimed.100%acrylic topcoats are to touch-up ColorPlus products. recommended.Do not paint when wet.For application rates refer to paint manufacturers specifications. Back-rolling is recommended if the siding is sprayed. COLORPLUSf TECHNOLOGY CAULKING,TOUCH-UP & LAMINATE I •Care should be taken when handling and cutting James Hardie®ColorPlus®products.During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product,then rinse with a garden hose. •Touch up nicks,scrapes and nail heads using the ColorPlusn Technology touch-up applicator.Touch-up should be used sparingly. If large areas require touch-up,replace the damaged area with new HardiePanelm siding with ColorPlus Technology. •Laminate sheet must be removed immediately after installation of each course. •Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPlus`'product dealer. •Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer. Note:James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up,will not be covered under the James Hardie ColorPlus Limited Finish Warranty. The following outlines the recommended applications for ColorPlus and Primed panels.Not all designs will be suitable for every application: •Exposed fasteners or battens is the recommended application for ColorPlus panel products •Do not use touch-up over fastener heads for smooth ColorPlus products-primed panel recommended •For ColorPlus panel applications that require fasteners in the field,it is acceptable to use touch-up over fasteners for Cedarmill and Stucco panel only,but correct touch-up application is important.Some colors may show touch-up when applied over fasteners.Trim is recommended to cover joints when appropriate. PAINTING JAMES HARDIE'SIDING AND TRIM PRODUCTS WITH COLORPLUS®TECHNOLOGY When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application: •Ensure the surface is clean,dry,and free of any dust,dirt,or mildew •Repriming is normally not necessary • 100%acrylic topcoats are recommended • DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie Products •Apply finish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature RECOGNITION.In accordance with ICC-ES Evaluation Report ESR-1844,HardiePanel®vertical siding is recognized as a suitable alternate to that specified in:the 2006.2009.&2012 Interrational Residential Code for One-and Two-Family Dwellings and the 2006,2009,&2012 International Building Code.Hard ePanel vertical siding is also recognized for application in the following:City of Los Angeles Research Report No.24862.State of Florida listing FLe889,Dade County,Florida NOA No.02-0729.02,U.S.Dept.of HUD Materials Release 1263c,Texas Department of Insurance Product Evaluation EC-23.City of New York MEA 223-93-M,and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of the product for specific applications. ®2013 James Hardie Building Products. All rights reserved. Additional Installation Information, TM,SM,and O denote trademarks or registered trademarks of James HardieTechnology Limited�9 is a registered Warranties,and Warnings are available at James Ha rd ie trademark of James Hardie Technohgy Limited. www.jameshardle.com HS1236-P3/3 6/13 • FL_ I38t5 . t Client: Pella Corporation 11111ffi_ Project#:415-0309 Report#:0507-4 Prepared by: RJA PTC PRODUCT DESIGN GROUP,LLC Date:5/26/2015 P.O.Box 520775 Page 4 of 11 Longwood,Florida 32752 MULLION END ANCHORAGE: 1. Calculated performance is based on the following: Mullions anchor plates a. 512-A Wood mullion anchor clip. (316 stainless steel) e. 5071 installation type clip (A-653 Hot dipped Galvanized steel) MULLION ATTACHEMENT: 2. a. Mullion End Clip 512-A(Fin mull anchor clip) i. The end clip is secured to each end of window jambs using eight#10 x 5/8"wood screws below,and requires a minimum of 1-1/2'I wood buck thickness(See Detail A). ii For 6-1/2"plate attachment to both window frames use ten(6)#8 x 5/8"stainless steel screws. iii. For clip attachment to wood frame substrates use five(5)#10 x 2"long or longer wood screws per clip leg into the installation bucking or frame with a minimum of 1 1/2"embedment into substrate and maintaining at least 3/4"minimum edge distance is required based on the analysis used in this report for development of the load width and span. i ;rood -- u.. . a... :d::.. lY • CC;:. I ro^la...-e. • ,'��• Mullion End Clip 512-A(Fin mull anchor clip) Detail A ROBERT 1.AMORUSO,P.E. F.B.P.E.CERTIFICATE OF AUTHORIZTION NO.25935 FL.NO.49752 Client: Pella Corporation MINIM! Client: #:415-0309 Report#:0507-4 Prepared by: RJA PTC PRODUCT DESIGN GROUP,LLC Date:5/26/2015 P.O.Box 520775 Page 5 of 11 Longwood,Florida 32752 f. Mullion End Clip 5071 i. The end clips are secured to each end of joined widow frames using a 6-1/2"steel plate#500M installed directely over both frames,then install two(2)5071 mull clips two at each side of the joined window frames, (See Detail B) ii For 6-1/2"plate attachment to both window frames use ten(10)#8 x 5/8"stainless steel screws. iii. For clip attachment to wood frame substrates use a total of four(4)#10 x 2"long or longer wood screws one per each clip leg into the installation bucking or frame with a minimum of 1 1/2"embedment into substrate and maintaining at least 3/4"minimum edge distance,for clip attachment to window frames through plate use two(2)#5/8"stainless steel screws per each clip is required based on the analysis used in this report for development of the load width span. iv For clip attachment to CMU or concrete substrates use a total of four(4)3/16"dia.masonry anchors one(1) per each clip leg into the installation bucking or frame with a minimum of 1 1/4"embedment into substrate and maintaining at least 2 5/8"minimum edge distance each clip anchor hole spacing must be located at least on 2 1/4"spacing between anchors,for clip attachment to window frames through plate use two(2)#10 x 5/8"stainless steel screws per each individual clip is required based on the analysis of this report for development of the load width span. •i 1 Clos 1 7` S tee LC. _ t'HC or 3-GC Jse - w _ri _i. t ,.acro- �: ^✓� � of the cr. • " st c•r..1•:SS • '•.j I d 1. Detail B Mullion End Clip 5071 ROBERT.I.AMORUSO,P.E. FL.NO.49752 F.B.P.E.CERTIFICATE OF AUTHORIZTION NO.25935 --- Client:Pella Corporation r,11. Project 0:415-0309 Report b:0507-4 Prepared by:RIA PTC PRODUCT DESIGN GROUP,LLC Date:5/26/2015 P.O.Box 520775 Page 7 of 11 Longwood,Florida 32752 ( ---- - 1 MUWON TABLE 1 t •j (VERTICAL OR HORIZONTAL SPAN—JOINING MULLION FOR WINDOW UNITS) I ( II CUP CLIP CLIP CLIP CLIP CLIP MULL LOAD MULL LOAD MULL LOAD TYPE TYPE TYPE TYPE - SPAN WIDTH SPAN WIDTH SPAN WIDTH TYPE TYPE 1 512A 5071 i 1 1 (in.) (in.) 512A 5071 (in.) (in.) 512A 5071 (in.) (in.) (PSF) (PSF) (PSF) (PSF) (PSF) (PSF) -- 24 85 85 24 68 68 24 30 30 II 30 85 85 30 56 56 30 24 24 36 85 85 36 48 48 36 21 21 42 85 85 42 43 43 42 18 18 36 • 48 85 85 66 48 39 39 9648 16 16 ••• 54 85 85 54 37 37 54 15 15 60 85 85 60 36 36 60 14 14 LOAD WIDTHsMf1+W2 66 85 85 66 35 35 66 13 13 2 24 85 85 24 57 57 30 85 85 30 46 46 36 85 85 36 40 40 • ' • 42 85 85 42 35 35 - — ". 42 72 48 85 85 1 48 30 30 54 85 _ 85 54 27 27 60 85 85 60 28 28 66 85 85 66 28 28 24 85 85 24 48 48 ' 30 85 85 30 39 39 I 36 85 85 42 85 85 78 36 33 33 48 42 29 29 1 I. 48 85 85 48 27 27 54 85 85 54 25 25 — 60 85 85 60 23 23 66 85 85 66 22 22 — 24 85 85 24 41 41 30 85 85 30 33 33 LOAD WIDTH=WI.+W2 36 76 76 36 28 28 2 42 69 69 42 25 25 54 84 48 66 66 48 22 22 54 65 65 54 21 21 60 65 65 60 19 19 THIS CHART APPLIES TO MULTIPLE WIDE 1 HIGH,VERTICALLY OR 66 65 65 66 18 18 HORIZONTALLY. 24 83 83 24 36 36 30 68 68 30 29 29 LOAD WIDTH MUST BE CALCULATED USING LARGEST ADJACENT 36 59 59 36 25 25 (SIDE BY SIDE)WINDOW HEIGHTS OR WIDTHS. 60 42 54 54 90 42 21 21 48 50 50 48 19 19 MULL SPANS ARE RESTRICTED BY THE LONGEST SPAN,(All TABLES). 54 48 48 54 18 18 60 47 47 60 16 16 WINDOWS MAY BE INTERMIXED COMBINATIONS OF CASEMENT, 66 47 47 66 15 15 AWNING,PICTURE,IN-SASH AND DIRECT SET GEOMETRIC OR RADIUS AND DOUBLE HUNG,(ALL TABLES). 'Use this table for intermediate 2-way mullions. ALLOWABLE PRESSURES ON THE MULLED ASSEMBLY SHALL BE CONTROLLED BY THE LESSER OF MULLION OR THE `For anchor clip attachment to substrates, INDIVIDULE WINDOW UNIT. see notes on sheets 4&5 on this report. ROBERT J.AMORUSO,P.E. F.B.P.E.CERTIFICATE OF AUTHORIZTION NO.25935 FL.NO.49752 Client: Pella Corporation =__ Project k:415-0309 Report#:0507-4 Prepared by: RJA PTC PRODUCT DESIGN GROUP,LLC Date: 5/26/2015 P.O.Box 520775 Page 6 of 11 Longwood,Florida 32752 REFERENCED DOCUMENTS: 1. AAMA 450-06/09/10 2. Florida Building Code a. Current Edition of the Florida Building Code(FBC),Building Volume Chapter 17-Mullions b. Current Edition of the Florida Building Code(FBC),Residential volume Chapter 6-Mullions I I ROBERT J.AMORUSO,P.E. F.B.P.E.CERTIFICATE OF AUTHORIZTION NO.25935 FL.NO.49752 rn 4—, y 1 .O O 3 0 qq! ,, o bA CL o -0 0 U Q. ca _o N M M —. • lb � � �W .. oal VJC rCt� o6 Ua DOVO1o ; F, 75 cii `� ---- o t a " -O° yQ a.� , o, 4 d t bob w. o O U F w .osa. . cn Wv U .. CJ a ° o,ta. 'a' LL ., � •� o c 0 w W o ct .y W ^d t.O Q t A b �'z �o > • 1 �El::: 'En 0 a' fcill.�: }- T.1 Ili � � = 2.! rj a a 0 at � J v' , p.› ....., ,x.., . A., JOLx - �_ , , - d LU oa .0 1- CI a VI en cl o ' o c `>4x_ O O f. E u a U b0 bA .G C At -v t' LI) '� bn ° o a> ° v o z .� -d b a o ;o .� — o a, O o .z N a) • cn .� d � 'c -o W • a� o o A o o o _ o f cn FA cn a d O , , in x U 4. a s 3 Q' 2 Q" U W •--• N M V N v 3 N M tri c� 00 °1 O •--i •O •O - s.. ^d a. a d �° >, u,,V _ - - - - I 4t 71 v 0 14 I , .� N o N cn au y 4. O 0 .E a a Cl J A (3- -D 0. V) r . - - - - - r-_ wi I i w CA a a c� i ..WZ w cit h 3-4 gI a) 5 ' U S a m o o 0 A v, aai o o > > o v a 5 3 > O a 0 o t3" v) w U 0 , >, '� ... in � cs ,� tato 0 a O .� 0 y ba O, p, op op `" op 4. "0, ca °oWno $ o ° ° v o �s cai fs, a °o ° o a oQ, O Qv) ) wv) 3C Do ¢ xzaa � xx33xaUxv) °© cn • o 4.4 w N r•-; v vi too a; a N cri .1: vi t.---: oo aO (V ri vi \e> •iU UA 1 lt ereiu O *7 It 1 a> II, a) V O C O C•43 E a o o. a) A a) 0 V + 0 AO L I a) 3 U 4o. ' � l l _ . r 7 1 - '_-_-_._ • . . , r I 6. I ! O os N 4 am a r v il _ i cu ci) o = W 'U it •G ' ¢, �. E'. z U N 00 1-.). v 1. O O Q C4 U rx 4 O p; i 3 E-� W cx U U ,4 .� a A 3 rri) O n EA fi • 1.0 = NM d• kr; 4p [� O --+ (-i M 4 v'; �p 00 O� C; ,9,..1 .M-. col --• U W f=. C45 • - • - - - - - - - • - • 0 a> ....r:4, -6 v 8 ,' 0 0=o t ....9 O. a.0 En � -cs i (,) ° 0 0 o v -alU_ u K. o14 LL. 4 7.3o LL. b N y 4. i 1, O O y § '5 .6 t (-/.. ii) H Ta. E o Q cA0 0. S.a Ts 0 c4 c a, .� c gi N \r . /‘ '7: Is o t. co� dy E b o .0 lis V) ‘.19--r ,..,-- 1 0 ,... 0 . .r.., ,.. o.. _ O a c 'El ^� �, 1� .E l• c., 8 .0 co ..\--) w -o v V 0 O r J \� Ci) 0404 ••'... OJ (� TMJ 0 Q .C,./2 O V '2 o Ci a 1 z "� , , osU w 0 0 �' E 0) - �C a o . • Q -g ;Z -o o z W 8 CA 11 _Si b z 5 '�' WW 0 00 4- >, ¢ 2 g ON Z W ~ ri b g — .-r -0 00 b o. Q a U x O _ U •U U H U _ _ U . OFFICE COPY 2EMENTWIND PRESSURE TO COMPONENTS&CLADDING (MRH 25') DESIGNATES: ZONE EFFECTIVE WIND AREA WIND LOADS NEW PELLA WINDOW Positive Negative NEW WINDOW TRIM 10 Sf +41.0 -44.5 Interior 20 Sf +39.1 -42.6 50 Sf +36.7 -40.2 100 Sf +34.9 -38.3 �. z.-X 10 sf +41.0 -54.9 "fix� w'�.,, . i .a„ -T'4 Exterior 20 sf +39.1 -51.3 A ' yiam 50 Sf +36.7 -46.3 sem J 7l .,rit"" '" 100 Sf +34.9 -42.6 • 77. AWS Design Pressure = Ultimate Pressure X .6 EXISTING 5/8" PLYWOOD SIDING F (REMOVE BATTONS) PELLA Z FLASHING NEW PELLA WINDOW 1!0 BATTON el 8" PEEL & " CK INSTALL ACCORDING `rTO PELLA INSTALLLATION SILL, F '• ING INSTRUCTIONS ATTACHED lARDIE PANEL" WINDOW FLASHING DETAIL IDING r — r- DESIGN INFORMATION ;;7e:-,?:: BUILDING CODE RESIDENTIAL FBC 2014 5TH ADDITION Pis: WIND SPEED 130MPH - IMPORTANCE FACTOR 1 f�z WIND EXPOSURE EXPOSURE C ENCLOSED `,< TYPE OF CONSTRUCTION TYPE V - UNPROTECTED OCCUPANCY CLASS R-3 �- "' " REMODEL CATAGORY LEVEL 1 SMITH RESIDENCE _AST ELEVATION 1345 SEMINOLE RD ATLANTIC BEACH FL 6-15-2017 SHEET 1 OF 1 • WINDOW REPLA( ,, ,: REMOVE AND =- —+ REPLACE WINDOW`. .-: REPLACE DOOR WHERE INDICATED • 11.111111111111111111111111111111111111111.11111.11.1111111111111".1111111".11 -- \ : 1 I ....i"4., '3.:s.. •rE._.:$SAF:. ... 4 NEW SIDING WEST ELEVATION REMOVE BATONS &APPLY OVER EXISTING PLYWOOD'S DIN ( z I I. 1 C-- NEW SIDING - SOUTH ELEVATION REMOVE BATONS &APPLY "I- OVER fOVER EXISTING PLYWOOD 5 •REPLACE WINDOWS WHERE INDICATED c3r-:',z.,--t: .-7..,`"I'V = /X/ \. , I�� x I Y. .,,,, •g��y��. ._,.;7,,.•,'`.s!':',".,/^7,:,.,,,.. t .,„.. <1 NEW SIDING -{> E REMOVE BATTONS & APPLY "HARDIE PANEL" — OVER EXISTING PLYWOOD SIDING 1