2343 Beachcomber Tr re-roof permit CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEWT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF17-0006 Description: ROOF-SANTEE FE S CLAY TILE Estimated value: 44785 Issue Date: 7/11/2017 Expiration Date: 1/7/2018 PROPERTY ADDRESS: Address: 2343 BEACHCOMBER TR RE Number. 1694630145 PROPERTYOWNER: Name: ADAMEC MARK A Address: 2343 BEACHCOMBER TRL ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: SCHULTZ ROOFING COMPANY INC Address: 216 N 20TH ST 216 N. 20TH STREET JACKSONVILLE BEACH, FL 32250 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For RVAC work,a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road Rkft 1 (47 Atlantic Beach,Flonda 32233-5445 Phone(904)247-5826 Fax(904)247-5845 is d routed: E-mail: building-dept@wab.us Da City"b-site hthe:/AsmAv coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Z34---� Department review reguired Yes No R UL Building T_Z pC) 0 1 �'D C Applicant: Planning &Zoning Administrator Project: 01 Public Wo 'IS--- Public Utilities Public Safety Fire Services Other Agency Review or Pennit Required Review or Receipt Date of Pennit Verified By Florida Dept,of Environmental Protection Florida Dept.of Transportation St.Johns RiverWater Man Any Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: V14pproved. ElDenied. E]Not applicable (Circle one.) Comments: BUILDING P LA qNI iNG�8,tiO N�J N G Reviewed by: Date: TREE ADMIN. Second Revisav: E]Approved as revised. E]Denied. E]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date:- FIRE SERVICES Third Review: ElApproved as revised. DDenied. E]Not applicable Comments: Reviewed by: Date:- Revised 05/1912017 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH goo Seminole Rostd,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 Rcc;,f-- 1-7 -000(4? Job Address: Permit Number. Legal Description UI)i # oor 01 Sq.1-t. 0+17L valuation of Work s V4 -7 W���00 :�=. 1. 795-00 Proposed Work heated/cooled— non-heated/C001ell— Class of Work(eircle one): New Addition Alteration Re Move Demolition pool/spa window/door (�F Use of existing/prorsed structure(s) ircle one): Commercial are,is a ram spn ter system installed? 0 ]if an existing strike u tial o N/A VC 5 F/ Florida Product Approval# -0- / Y31 7 For multiple products ma,product approval Tom if5or Describe in detail the 4W of work to be performed,— sRwk fr- S C (�4 ti k Proverty Owner Information: Nam: fy)ox]�..Ar, Ajowe-c- Address, Ll 3 &94�rn CityfjjjQnjc- J��eg,�Snud--J-Zip— -�Phorie qO14 21A Cia E-Mail or Fax 9(Optional) Contractor]Information: Company Name- I -QVi Agent ou cis Pf . sc�,t�a :?- - Y--i 71, 6iiiWihoneq0q-,�?kAta-a315 JobSrle/ComactNurnber Fax# Qq State Certification/Registration Architect Name&Phone# Engineer's Name&Phone Fee Simple Title Holder Name and Bonding Company Name and Address Mortgage Lender Name and Address Applimthm is hereby made wabrain a p.mail 40 do the work and installatums as oularded I certly,that no work or installation has commencedprior to the issmame,ofa permit anduad allwork will be 76�=d to met the standards ofall lews mplatioti e.mametion or this jurisdiction. 7hispermit bucoms null Zvoidffworkisnmco�e�dwahinsix(6, months,or ifcoosametion or work is frimied or abandonedJor aWeriod qfsa�6.),months at anytime after kiscommenced funder�mdihasep"epemia�tbese�edf�Elemi Work,Phoubtfig-S19014 db%P00h; ssmoae�Bomemffealm, TanksandAirCandeassumn,me. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING V614i NOTICE OF COMMENCEMENT. I wr,*that I harm mad andenummedth" *4i�ionandi�thes�etobe"eandc�t� Allp��i�V .W-dl=gv�n.�rb, 1, Pie'd herein or nor The granting of a joermir does nod luessom to gn'Pzw ly to or ComV .,L.am,mgulating consurmtion or the pfforosance efcoustraCtiout SignatureofOwner Signature of contractor I�L PrintName nkc, k NAO-Met- Print Name -, XS4-(�� Sworn to and subscribed before me Sworn to and subscribed before me th Day of -M a 6 �201J AID f-fh--0x8r 20 /9 N6tmy Public ------M+� OBIN C MOOR nO814�c MY rOMM'S 0�""041 EXPAeS Juss 30 2 OF7— --ry CITY OF ATLANTIC BEACH 800 Seminole Road JUN 2 9 20V Atlantic Beach,Florida 32233 Telephone(904)247-5800 FAX(904)247-5845 0 REVISION REQUEST SHEE TOR CORRECTIONS TOO �W COMMENT Date: I Received by: Resubmitted: Pen2�!L�.-- D--0— 0 11 -00(ya Original Plans Examiner: !�,,7tNamie: ProjectAddress: ),34 Contractor: f2LOFinq cu Contact Nat Contact Phone: '(04 �LY( ZL73)!� - C mail: Revision/Plan Check I Permit Fee (s)Due- S Description of Pro osed Revision to Existin Per it: -f7 77/ Ic Additional Increase in Building Value: AdditionalS.F._ Site Plan Revised: Public W U Approval: By signing below.I tp�t i T�.U4 5C-b,))f2- affirm that the above revision is inclusive of the proposed changes. ��L Signature of Contractor/Agent(�tw mm sip irinc�in vat"inn) Date office Use Only D. ?. 2 A�M x Nmirdby:_ Plan Review Comments: Deroartiment review requil Yet No Planning&Zo g Plans Examiner nin Trans Administrator Public Works Public Liffilffies, Public Safety Date Fire Services NOTICE OF COMMENCEMENT P.ftN.. R60 -fn— 6ti,56 Tax Folio No. State of 1—� ummy or "LIVAL To whom it may concern: The undersigned hereby Informs you that Improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following information Is stated In this NOTICE OF COMMENCEMENT. Legaidesc f property baing Improved: `A;-0e-anV&tk/ KFC-43, e)l Q / —7 5 — S—) Addressofiruop bw?Imprngd' At-"-kczt�ke�- —7 r-.x e 0=i02 C, 0�7 General description of imp,mermards: Owner eL n?e r— Address /3 eecu� Frirresk Or. Owner's Interest in site oMe improvement Fe y L-�m 02)e- Fee Simple Titleholder(it Omer Man owner) Name Address Contractor �k U- I f X k0D-Wn r, 6r,- c Address (0 11�t I '-JWJ:!;SQQU' lk /*a Ct- PhoneNo. F..No. 410 Y Surety hif any) Address Amount of bond 8 Phone No. Fax No. Name and address of any person Making a loan for the wnstruclion of the improvements. Name Address Phone No. Fax No. Name of person within Me State Of Florida,other Man himself,designated by owner upon whom notices or other comments may be sewed: Name Address Phone No. Fax No- In addition In himself owner designates the following person In receive a copy of the Lieran's Notice as provided in Section 713.06(2)(b).Florida Stadiums.(Fill in at Owners orAon). Name Address Phone No- Fax No. Expiration data of Notice of Commencement(the expiration data is one(1)year from Me data of recording unless a different date is specified): THIS SPACE FOR RECORIDER'S USE ONLY slreo: R DATE ...IhN� - h -M'- - -, `w-'- raily�P�P�md Doc 4 2M 712T720.OR BK 18002 Page 81, 4w . =42 Ntunber P havew hsr�xhrd seers Use MlHatecvrra�d dedurseWS neran agew .#vWWW...W Recorded 06101 1.2017 at 11:51 AM. Ronnie Fussell CLERK CIRCUIT COURT DUVAL ROBN C MOORE I COUNT'Y RECORDING$10.W W COMMISSION 0 FF24571 Lf SJun*30.2012 M,.voaicn.'n'.e -calmi LJG Engineering, Inc. Principal Engineer: Louis Gabriel PE 419 Sophia Terrace Saint Augustine , Fl . 32095 Ph # (904) 982 1935 6/ 21/ 2017 City of Atlantic Beach Building Dept. Subject: Proposed asphalt Roof shingles replacement with Santa Fe "S" Clay Roof tiling at the residence located on 2343 Beachcomber Trail Dear Building Official; The subject residence existing asphalt roof shingles will be going to be dismantled and removed, then replaced with brand new light weight clay tile. The Clay tile roofing system that will be used goes by the commercial name "Santafe "S" Clay Roof Tile and is manufactured by Ladrillera S.A. in Bogota Columbia. Upon reviewing the product approval documentation and the technical specifications of the product with emphasis on its structural properties such as its weight , nailing, restoring moments due to gravity and compare those to the existing roof truss framing and existing concrete foundation I have concluded that the existing roof plywood sheathing and the existing roof trusses and the concrete foundations will not experience any increase in the roof loading due to the light weight clay tiling and will be adequate as is. Therefore, it is my professional opinion that existing shingle replacement with the subject product will not warrant any further stiffening of the existing trusses or any beefing to the existing roof plywood sheathing or any modifications to the existing concrete footings. 9111- Attached to this acceptance letter you should find the owing documentations; 004 7- 1- Copy of the product approval and technical specifications, reviewed and stamped by me. 2- Copy of the existing house roof profile 3- Copy of the existing house foundation plan six& ze ' . 1 ';�Louiz Jr*.�'Gabriel , PE Ok �P- W', 0, Farodfw� I !pProval LISER: ft C W 40: ProductApRrovai Me Product or Appli ation Seatch> Application Li >App"Gailumph season FL* FL2019-R4 Application Type Revision Code Version 2007 Application Status Approved Comments Archived Product Manufacturer Santafe Tile Corp Address/Phorne/Email 8825 NW 95 Street Medley, FIL 33178 (305) 885-9002 artumposadaduran*yahoo.com Authorized Signature Artunct Posada artumposadaduran@yahoo.mm Technical Representative Arturo Posadis Address/Phone/Email 8825 NW 95 Street Medley, FIL 33178 artum�ntafe@aol.com Quality Assurance Representative Arturo Posada Address/Phone/Email 8825 NW 95 StreeLJG ENGINEERING,INC. Medley, FL 33178 419SOPHIATEFIRACE (305) 885-9002 ST AUGUSTINE,FLORIDA 32095 arturosantalre@aolfitcliffiRT OFAUTHOREZATION No.9784 SHOP DRAWING REVIE DISPOSITAON Category Roofing VeZ;;;OVEO 0 APPROVEDAS NOTED Subcategory Roofing Tiles 0 NOTAPPROVED BY DATE WT)120 Compliance Method Certification Mark bogiftle"Reford. FL.Carl No.39476 LOUIS J.GABRIEL, RE. ITtWN: Rene.of shop foremnlis 's O'l, Certification Agency Miaml-Dade BCCq11r conformance with the design contest of Validated By Miami-Dade BCCQwYkk,,nd does of refithethe deleg��id engineer Of responsibility to, an,dev - n tram the requremonts of the contract memo nor from responslistit,for O,r ontsmatts,ri the Shop drawings Referenced Standard and Year (of Standard) Standard Year ASTM C1167 2003 TAS 110 2000 TAS 110 2000 Equivalence of Product Standards Certified By Product Approval Method Method I Option A Date Submitted 04/14/2009 Date Validated 05/07/2009 Date Pending FBC Approval 05/08/2009 Date Approved 06109/2009 Summary of Products "c� ;FL iModel, Number or D ptlon Name ,2019.1 Mission Barrel Clay Roof 'Mission Barrel CJay Roof Tile, 160 pieces Tile I j per square LIMNS of Use rtification Agency C*ftiflc§t* Approved for use in HVHZ: Yes FL2019 R4 C CAC NOA Mimign BMW Approved for use outside HVHZ: Yes Tilc.pd Impact Resistant: N/A Quality Assurance Contract Design Pressure: N/A I Expiration Date ' Other: Refer to Concrete and Clay Roof � 10/13/2012 Tile installation Manual (Florida Roofing, Installation Instructions Sheet Metal and Air Conditioning 1 FL2019 84 11 NOA MISSWR B11=1 S11111 Contractors Association, Inc). and Miami 7ile Of Dade NOA# 07-0626,04 Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2019.2 RIVIERA INTERLOCK INTERLOCK CLAY ROOF TILE CLAY RO OF TILE 11.1mits-of Use Certification Agency Cert1flicate, I r Appravvidforuve inHVN_Z:­YW_ F1,2019 R4 C CAC NOARjvi=05- Approved for use outside HVHZ; Yes 120104.0 Impact Resistant: N/A Quality Assurance Contract Design Pressure: N/A Expiration Date Other: 03/16/2011 Installation Instructions E1,29 19 R4 11 NQA Rivi=25-12Q2,94,Dd Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2019.3 knoyal dij Roof�file­ Royal Clay Roof Tile, 96 pie.ces-p.er square Limits of Use CertIfIcjtI�Ajjncy Approved for use in HVHZ: Yes I FL2019 &4 C CAC NOA RRY21 QjwQ221.01.Ddf I Approved for use outside HVHZ: Yes Quality Assurance Contract Impact Resistant: N/A LExpiration Date Design Pressure; N/A OZ/01/2011 i Other: Refer to Concrete and Clay Roof Inxtellation Instructions Tile Installation Manual (Florida Roofing, 'EL2019 R4 11 N0ARQyWQ5-Q92J.0l,9d I Sheet Metal and Air Conditioning I I Verified BY: Miami-Dade BCCO- CER I Contractors Association, Inc. and Miami I Created by Independent Third Party: Dacle NOA# 05-0921.01 Evaluation Reports Created by Independent Third Party; 2010.4 Santafe Flat Tile 1131 Pieces per Sq Limits of Use Certification Agency Certillcate, --- Approved for use In HVHZ: Yes FL2019 R4 C CAC NOA Siulnifl;E14 Tik Approved for use outside HVHZ: Yes 08070906.odf Impact Resistant: N/A Quality Assurance Contract Design Pressure; N/A Expiration Date Other: Refer to Concrete and Clay Roof 09/18/2013 Tile Installation Manual (Florida Roofing, Installation Instructions Sheet Metal and Air Conditioning ! FL2019 R4 11 NOA SAntaftHAI-Till Contractors Association, Inc. and Miami 08070906 lid Dade NOA* 08-0709.06 Verified By: Miami-Dade 8CCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2019.5 Spanish ' " Clay Ro-of Spanish "S" Clay Roof Tile, 96 pieces per rile square Limits of Use Corthricatflon Agency Certificate Approved for use In HVHZ: Yes FL2019 R4 C CAC NQAS�wish S Sanla_f� Approved for use outside HVHZ: Yes 07062601Dd Impact Resistant; WA Quality Assurance Contract Design Pressuret N/A Expiration Date Other: Refer to Concrete and Clay Roof ! 02/01/2011 !Tile Installation Manual (Florida Roofing, installatlion Instructions Sheet Metal and Air Conditioning FL2019 R4 11 NOA Smish S$"lafe Contractors Association, Inc. and Miami 107062603.pd Dade NOA* 07-0626.03 i Verified By: Miami-Dade BCCO - CER Created by Independent Third Party- Evaluation Reports Created by Independent Third Party: MUMI-DADECOUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC�SOURCE;S(RER) 11905 SW 26 Stne,Ronn 209 WARII AND CODE ADMINISTRATION DIVISION MW���d.33175-2474 T(796)315-2590 F(786)315-25" NOTICE OF ACCEPTANCE (NOA) Santafe Tile Corporation S825 NW 956 Street Medley,Ft 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the we of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other arms where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid aft"the expiration date stated below.The Mimi-Dade County Product Control Section (in Miami-Dade County)andlor the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance Purposes.If this product or material fails to Perform in the accepted manner,the manufacturer will incur the expense of such testing and the AID my immediately revoke,modify,or suspend the we of such product or material within theirjurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Mimi-Dade County Product Control Section that this product or material felt to meet the requirements of the applicable building code. This product is approved as described hercin,and bas been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish IS'Clay Roof Tile LABELING:Each unit shall bear a permanent label with the manufactouvr's Dome or logo.city,state and following statement"Miami-Dadc,County Product Control Approved",unless otherwise noted herein. PENEWAL of this NOA shall be considered after a renewal application bm been filed and them has been no change in the applicable building code negatively affecting the performance of this product TERMINATION of this NOA will occur after the expiration date or if them bas been a revision or change in Lhe materials,me,and/or manufacture of the product or process.Mime of this NOA as an endorsement of my product, for sales,advertising or my other purposes shall automatically terminate this NOA.Failure to comply with my section of this NOA shall be came for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida,and followed by the expiration date my be displayed in advertising literature. If my portion of the NOA is displayed, then it Shan be done in its entirely. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0210.01 and consists o f pages I through 5. The submitted documentation was reviewed by Caspar J Rodriguez. NOA No.: 15-0915.09 E.pintion Daft: 02101121 Col.—=P Approval DOC 01/2LI16 Page I of5 ROOFING ASSEMBLY APPROVAL Careen": Roofing Sub-Cateeory: Roofing Tiles Material: Clay Deck Type: Wood I. SCOPE This approves a roofing system wing Santa Fe"Santsfe'S"Clay Beef Tile,as manufactured by Lachilleas, Santale S.A.in Bogota,Colombia and distributed by Somalia Tile Corporation as described in Swam 2 of this Noticcol'Acceptaince. For locations where the press=requirements,n determined by applicable Building Code,do not exceed the design preisiame values obtained by calculation in compliance with RAS 127 wing the valucis listed in section 4 herein. The attachment calculation shall be done as a moment based system. 2. PRODucrEiEsciurpnoN Manufactured by Test Product Applic" Dimensi Specification Dwriptlan Sairmf6'S'Clay Roof L= 18' TAS 112 One piece high profile clay mf tile equipped with Tile W—11.1" Type I Two nail holes. For nifil-on,ructur set and adhesive Thickness=0.390 Grade I set applications. Trim Pieces I=varim TAS 112 Accessory trim,clay mof pieces for use at hips, w=Varies Takes,ridges and valley Terminations. Manufactured varying thickness for each tile profile. 2.1 MANUFACTURING LOCATION 1. BogotsColornbia 2.2 SUBMITTED EVIDENCE Test Aeen Tat Identifier Test Naracilkepa Date The Center for Applied Engineerin&Inc. 94-156-8 TAS 101 Aug. 1994 94-156-9 TAS 102 The Center for Applied Engineering,Inc. 25-7205-1 TAS 101 Much 1995 The C�enaer for Applied Engineering,Inc. Project:07-07-00-91 TAS 100 Sept. 1994 (307023) Redland Technologies 7161-03 TAS 108 Dec. 1991 Appendix 11 (Nail-On) Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102&TAS 102(A) Raffland Technologies P 0402 Withdrawal Resistance Sept. 1993 Testing of Screw vs smooth shank nails Rediand Technologies P 0647-01 TAS 108 Aug. 1994 (Mortar Set) NOA No,:15-0915.09 Expiration Date: 02101/21 Approval Date: 01/21116 Page 2 of S 21 SuBmITTED EwDENcE TestAnownt Test Identifier Test NstmeMesairt Date Redland Technologies P0631-01 PA 108 July- 1994 (mortar Set) Celolex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 113A Consultants,Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies,Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants,Inc. 2353-70 TAS 101 09/22/03 IBA Consultants,Inc. 2353-71 TAS 101 09r2M3 E3A Consultants,Inc. 2353-93 ASTIM C 1167 07/18/05 American Test Lab of South Florida RT0624.01-15 ASTM CI 167-03 07/01/15 3. LIMITATIONS 3.1 Fire classification is not pan of this iscauptance. 3.2 Far mortar or adhesive set tile applications,a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami-Dade County Product Control Section for reviev, 3A Minimum underlayment shall be in compliance vAtb the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped undeadaymern applications may be installed perpendicular to the roof slope wiless stated odkerivise by the underlaymerat material manufacturers published literature. 3.6 This acceptance is for wood dock applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Sarstafe 'S'and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120. 41 Data For Attachment Calculations NOA No.;15-0915.09 ExpirationDabe WWII Approval Dote: 01121116 Pap 3 of 5 Table 1: Average Weight(W)and Dimensions 0 x w rile Profile Weight-W(Ibf) Length-](ft) Width-w (ft) Isantak S, 63 1.5 0.959 Table 2: Aerodynamic Whipliers-AM") rile A(ft3) A(ft') Profile Ratten Anolication Direct Deck able 3: Restoring Wments due to Gravity - (ft-lbf) Tile 2":12" 3":12" 111 1211 5':12" 6":12" 7":12" or Profile I I I I I raster �.t ismem, I tArect I Banos I ILIVect I Mae., I eatuou, I V..1 Be n, I Dkt.t Mk Deck D..k lk�k D..k Seattle S' 1 5.93 1 1 5.69 1 5.56 1 5.53 1 �Jz 1 5.29 Table 4: Attachment Resistance Expressed as a Wment-K(ft-lbO for Nail-On Systems Tile Profile Fastener Type Durect DaCK Battens Santalb S, 2-10d Ring Shank Nails 21.8 VA One#9 Screw 29.16U MA Tm#9 Screw 38.291 _::�IIVA— N, One#8 Screw w/CUP L74 NIA_ 5 61 771 T #11scre" W/Cup .60 tunnufiLcuiredbyothen'. 121. beuinswied ki the inside We io..wd neanstu,the h..P.f the Is.. Table 5: Attachment Resistance Expressed as a Wment h4(ft-lbf) for Two Patty Adhesive Set Systems T'le Profile Tile Application Nfinimum Attachment Resistance I Santak Tile Bond 353. PoWam Polypro AH 160— 1 29.54 2 See Inanuiscums com, omnt a Irovaistobsiampon moammenw. 3 Fkublee u,,,aU,.AwM,,e �jCht,crp,U,10.4q.nU. 4 P.1yke P.dct1n..A".M.jjhIU1 - 9.4 ---. Table SA: Attachment Resistance Expressed as a Wment-W(ft-lbf) fbr Single Patty Adhesive Set Systems Tile Profile Tile ADDlicad Mnimurn Attachment Resistance— Santak S, Po lbamPo W A" 160� Po am PoWm AH 160— kee t r 3 mon 0100 M M IOU` 1 P.dod'eF.MmOntOM anions flRobMAH160�. Table 6: Attachment Resistance Expressed as a Wment-?*(fk-ibf) forMortaror Adhesive Set Systems Tile Profile Tile esistance "On.,Rm 11 � NOA No.:15-0915.09 Expiration Date. 02101f2l Approval Date; 01/21/16 Page 4 Of 5 5. LABELING 5.1 All tiles shall bear the imprint or identiflable marking of the manufacturer's name or logo as shown below, or following statement:"Miami-Dade County Product Control Approved". SANTA FE TM MADE IN COLOMBIA LAzRL FOR SANTA FE SPANISH"S"CLAY ROOF TILE 6. BUELDING PERMIT REQuiREmENTs 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWfNG When using one screw use this hole, Is" .SANTAF]t S"CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.: 15-0915.09 Expiration Daft: 02101/21 Appro�al Date: 01121/16 Page 5 015