Loading...
380 5TH ST - RIGHT OF WAY JEA �3 fss. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD �11N ATLANTIC BEACH, FL 32233 ~4011 �% INSPECTION PHONE LINE 247-5814 RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW17-0011 Description: install 35 ft. wood pole for JEA Estimated Value: 0 Issue Date: 8/1/2017 Expiration Date: 10/30/2017 PROPERTY ADDRESS: Address: 380 5TH ST RE Number: 169850 0000 PROPERTY OWNER: Name: GIOVANNUCCI DANIELE Address: 380 5TH ST ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JACKSONVILLE ELECTRIC AUTHORITY Address: 21 CHURCH ST W 3RD FLR JACKSONVILLE, FL 32202 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. I ,---,_---- 11 _� Il JUL 5 2017 rS CITY OF ATLANTIC BEACH ��- -i ;._.. .% L Ili, CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF W AND�ASEMENTS 800 Seminole Road 904-247-5800 ;,;1 Atlantic Beach,Florida 32233-5445 _Fax 9b4-247-5845 PLEASE SUBMIT(3)COMP ETE SETS OF PLANS WITH APPLICATION. Date pti ! •7 C c PERMIT# V`�tl - 0 0 I Job Address ,3 '7 9 ,5----n--1 ✓J �os $ ISSUED BY THE CITY Permitee: 7j! I ��� Telephone# 6 .3---7793 Permittee Address: (/1 Gt/,0.4' 66u%U1.-> S/ Requesting Permission to Construct: -d l i1 (0 3S_ (�USS L/ frO90 d r7D e Location: (Reference to Cross-Street) ,cYl e r�� '2 ). ii 1. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority . Yes( ) No ( ) Date: Bell South Telephone Company Yes( ) No ( ) Date: Ferrell Gas Yes( ) No ( ) Date: Comcast Yes( ) No ( ) Date: 2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director•of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Q. S iN, SO.-, (Contractor's Project Superintendent)located at ZI (/. c vv4, r. rye Telephone#: (rho 5--77 J3 4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with (,O days. If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again immediately upon completion. OWNER Signed: Date: Before me this day of in the County of Duval, State Of Florida,has personally appeared Notary Public at Large,State of Florida,County of Duval. My commission expires: Personally Known: Produced Identification: 4 ,;5),Q,--,z,„. City of Atlantic Beach APPLICATION NUMBER S )t." -yr�� Building Department to (To be assigned by the Building Department.) �-- ; 800 Seminole Road Atlantic Beach, Florida 32233-5445 P---01-0 1 00 (f �;��..�w� ECE�VE� Phone(904)247-5826 • Fax(904)2 845 fj0 E-mail: building-dept@coab.us Date routed: ° 1 �,� I (1 City web-site: http://www.coab.us JUL 15 2017 APPLICATION REVIEW-AND—TRACKING FORM Property Address: - -i� - Department review required Yes No A Building Applicant: 3e-, Planning &Zoning • Tree Administrator Project: I I)StL1 Ii 3 5 �-i - QVl_Lublic W ks--`, • Public Utilities Public Safety / Fire Services Review fee $ X17 Dept Signature ki-i-A Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ATION STATUS Reviewing Department First Review: NtApproved. DDenied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING , � Reviewed by: Date: 746/ 7 ' TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ONot applicable PWORKS Comm nts: UBLIC UTILITIES, 9 ZS=/7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 1.ay;y City of Atlantic Beach APPLICATION NUMBER j r- r�, Building Department (To be assigned by the Building Department.) r. P800 Seminole Road EC �� �) v G �/ jv, W -` �.• Atlantic Beach, Florida 32233-5445 ECEIVE (904)247-5826 • Fax(904)247 �.� I `0;;19',= E-mail: building-dept@coab.us JUL 2 5 q0, Date routed: .. I (q City web-site: http://www.coab.us �u�/ APPLICATION REVIEV ANfrTR�►CKING FORM Property Address: 0 S Si • Department review required Yes No i • • Building Applicant: j `_i . Planning &Zoning (� L ( Tree Administrator Project: 1, i S I II 3 1"'k - PO'- I ublic Wor Public Utilities • Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS — _ Reviewing Department First Review: Approved.,�/� L ❑Deniied. ❑Not applicable (Circle one.) Comments: .4.e i oul 4:is t‘ 1Q BUILDING PLANNING &ZONING Reviewed by' Date: 7-'149-17 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 A • RI rt N , 'A at t• /0 M iiiii CD J CO •; • W CP j` ���V '�j`' W W �p \Ili O O* I cO ca tow W co j► I I� � W CA CO A.• ' O J 1 Ca cc.O A N i W CO W 1 0 m w 1 1 1 03 g t .......... W W w � V CO , BIER Vw ". n ww N V V it ii I WW N V • w Hii u , . . g .0 v Ca u Co1 Co 2 (rte a.. O Yu IX o Ca C.aV V 4. O 41. O g ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:30308 N.O.: 8003837 WO#: 30073124 CONST:07/25/17 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 563 REQ'D:YES CELL ENGINEER:Robert Simpson N.O.: N/A ZIP CODE: N/A CUSTOMER/ SVC PHONE LOCATION: 379 5TH ST./INSTALL 35/4W AND OH SEC 563 CENTER: SSSC N.O.:665.7793 STA 1, P# 379 5TH ST./ INSTALL 35/4W RUN 0 ^r1 p N 2/O TOSTA2. R J J Q 111 STA 2, P#378 5TH ST. 3 82 r 3 { , *****THIS IS FOR NEW BUILD***** 381 377 0 O '� STA 2 ,, 399 395 of 0 0 T Q T 'I4 � W /- :5 I - ` 1�� L--- a '� ~- !• - +i ` - 1/oI .Ai• ` $5 \ 65T ` � STA 1\ � 0♦ — "-' o-0 v. © ,k _ 0 n 0(1 JEA. CUE Reports Estimate Number:30308 379 5TH ST.35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30073124 Required Date: Oracle Project#:8003837 Estimated On: 07/20/2017 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $425.31 $425.31 2.Transformer Cost(w/sales tax) $0.00 $0.00 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $1,107.13 $791.82 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $756.49 $120.75 7.Engineering Costs(Variable%of line 4) $279.40 $221.31 8.Project Equipment Costs(40%of total equipment costs) $566.37 $0.00 9.Material Handling(8.30%of lines 1&2) $35.30 $35.30 10.Inspection(6.84%of line 4) $0.00 $54.16 11.Total Cost of Project $3,170.00 $1,648.65 12.Work Order Estimate(Line 11 minus line 8,9,& 10) $2,568.33 $1,613.35 13.Billable Equipment Depreciation(60%of total equipment costs) $849.56 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11 +13+(58.71%of 4&7)) $4,833.58 $1,778.58 15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $4,833.58 $1,778.58 Time Estimate Crew Hours Total Man houra 8.88 35.51 CUE Reports Estimate Number:30308 379 5TH ST.35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30073124 Required Date: Oracle Project#:8003837 Estimated On: 07/20/2017 CU Detail Station: 01 379 5TH ST Build Transfer Remain In Place Remove C.4/0P 45 G3W*2 1 GY3*5 1 P.35/4W 1 S20 1 S20ES*4/0-1/0 1 S4 1 S4*4/0 1 C.1/0T 55 Station: 2 3/8 5TH S T Build Transfer Remain In Place Remove RUBUP 2 S20 1 S20ES*4/0-4/0 1 S4`4/0 1 RUBDOWN 2 .Eit, CUE Reports Estimate Number:30308 379 5TH ST.35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task:30073124 Required Date: Oracle Project#:8003837 Estimated On: 07/20/2017 Material Summary Item Quantity Item Number Item Description 1 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZED 10"X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 1 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 45 CAIOS003 CABLE,4/0-19(PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE"VICKSBURG" PRE-ASSEMBLED PARALLEL 1000 FOOT REELS 1 CLAGROO1 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 CLASR002 CLAMP,STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP 1 CLASR003 CLAMP,STRAIN RELIEF WEDGE MESSENGER, SIZE:#6-2/0 2 CLASS006 CLAMP,STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM 3 CNNCP002 CONNECTOR,#2,6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 2 CNNCP006 CONNECTOR,#6, 1/0-2/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 3 CNNCP007 CONNECTOR,#7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 1 CNNCP008 CONNECTOR, #5, 6-2 MAIN, 4/0 TAP, COMPRESSION, PARALLEL TAP, ALUMINUM, 2 CNNVG003 CONNECTOR, 6-2 SQL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 16 COBCO028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER,200', 25#, ON PLASTIC REEL,4"X 11.5"W/2"HOLE 70 COBCW014 CONDUCTOR,#4,TYPE 40 DSA, COPPERWELD&COPPERWELD- COPPER .204" DIAMETER 1480#BREAKING STRENGTH (50#COIL- 427') 4 COVIC002 COVER,"D"DIE, INSULATING,2-1/2" 1 GUAGW001 GUARD, GROUND WIRE, 1/2"X 1/2"X 96",GRAY PLASTIC 1 GUAGW002 GUARD,"YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7/16"GUY STRANDS(DISTRIBUTION) 1 GUYAT008 GUY HOOK.COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT. STRENGTH. FOR WOOD OR CONCRETE POLES 2 GUYGROO1 GRIP, GUY, 3/8",26",GALVANIZED 1 50 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B"GALV. OR BEZINOL IS ACCEPTABLE (500'COIL) 1 INSG6002 INSULATOR, STRAIN, GUY BREAKER,21,000#RATED,60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 3 INSSU002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 1 POLW0003 POLE,WOOD, 35'CLASS 4 (T/L=44),WEIGHT=1,026 LBS 1 RODGR003 ROD, GROUND,THREADLESS,5/8"X 8',SHIP ON OPEN FLATBED ONLY! 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5" HIGH X 2" WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. .1F1. CUE Reports Estimate Number:30308 379 5TH ST.35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#lTask:30073124 Required Date: Oracle Project#:8003837 Estimated On: 07/20/2017 OF 50 EACH) 1 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2" DIAMETER, GALVANIZED, *** 500 EACH PER BOX*** 1 WASSF003 WASHER, SQUARE FLAT, 3" SQ X 1/4", 5/8"X 3/4"BOLT SIZE, GALVANIZED 1 WASSP002 WASHER, SPRING, 3/4" BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) 61. CUE Reports Estimate Number:30308 379 5TH ST.35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC Estimate Version: By: SIMPRB MWO#/Task 30073124 Required Date: Oracle Project#:8003837 Estimated On: 07/20/2017 CU Summary �i ; r3 y r S�, 3pw afp�E s_i�,.,�.�T G F� a r� k haR ° .-`h�x� �y���.Ct�, k '�-F., r f2� �;: sn ad i,� fz+•f� :W 'f IA�tf�.vD` �xx� E�..fi CU Nam@Quantity Qescriotion C.4/0P 45 4/0 AAC PAP W/4/0 AAAC NEUTRAL G3W*2 1 WOOD POLE-NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8"DOWNGUY W/8 FT SCREW ANCHOR P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 2 LINE RUBBER INSTALLATION, PER SECT. S20ES"4/0-1/0 1 SECONDARY CONNECTION AT POLE S20ES`4/0-4/0 1 SECONDARY CONNECTION AT POLE S4*4/0 2 SECONDARY DEADEND a t }y•••-•417,;..,�w•'• 10,:.:7;. • • - -4.1 a M i'lq:T ,YYti� e tenr:OZ w , >s r .. ~,. . � ` ' tiYar ;at y = A CU Name Quantity pescrlotlon C.1/OT 55 1/0 TRIPLEX RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT.