Loading...
2028 BEACH AVE - SOLAR CITY OF ATLANTIC BEACH 7.3 ,\,________/, 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ELECTRICAL SOLAR PANEL - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: SOLR17-0007 Description: SOLAR PV ELECTRIC ON ROOF Estimated Value: 31282 Issue Date: 7/27/2017 Expiration Date: 1/23/2018 PROPERTY ADDRESS: Address: 2028 BEACH AVE RE Number: 169701 0100 PROPERTY OWNER: Name: RAPP MATTHEW H Address: 1031 FIRST ST S#1001 JACKSONVILLE BEACH, FL 32250 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: A1A SOLAR CONTRACTING INC Address: 10418 NEW BERLIN 223 JACKSONVILLE, FL 32226 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. ri = Cash Register Receipt Receipt Number 7 g p City of Atlantic Beach R2134 111 DESCRIPTION I ACCOUNT QTY PAID PermitTRAK $213.00 ERES17-0069 Address: 2028 BEACH AVE APN: 169701 0100 $94.00 ELECTRICAL $90.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 ELEC REPAIRS AND MISC 455-0000-322-1000 0 $35.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0600 0 $2.00 STATE DCA SURCHARGE 45500002080700 0 $2.00 SOLR17-0007 Address: 2028 BEACH AVE APN: 169701 0100 $119.00 ELECTRICAL $55.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 MECHANICAL $60.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 SOLAR COLLECTOR SYSTEM 455-0000-322-1000 0 $30.00 STATE SURCHARGES $4.00 STATE DBPR SURCHARGE 455-0000-208-0600 0 $2.00 STATE DCA SURCHARGE 45500002080700 0 $2.00 TOTAL FEES PAID BY RECEIPT: R2134 $213.00 Date Paid:Thursday,July 27, 2017 Paid By: A1A SOLAR CONTRACTING INC Cashier: CT Pay Method: CREDIT CARD 088790 Printed:Thursday,July 27,2017 3:07 PM 1 of 1 nwor , ,,:o.. .i, City of Atlantic Beach APPLICATION NUMBER j' - , Building Department (To be assigned by the Building Department.) r 2 800 Seminole Road C 7 Co0 J r Atlantic Beach, Florida 32233-5445 C _ t ! — Co 7 Phone (904)247-5826 - Fax(904) 247-5845 -7 / / x�u;t!>,' Email: building-dept@coab.us Date routed: ! t/ ( t/ City web-site: http://www.coab.usil APPLICATION REVIEW AND TRACKING FORM Property Address: Z Ole, '3 €\Q. c.--k UE Department review required Yew No c Buildin 1/ Applicant: A J l I\ OL k,.. 0 _pt,.. Z' Planning -Zoning Tree Administrator Project: oLA 2 PV O,..a Rc7 O ---- Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District _ _ Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ATION STATUS Reviewing Department First Review: L Aipproved. Denied. I INot applicable (Circle one.) Comments: (BUIL .1 PLANNING & ZONING Reviewed by: Date: 7.25"=f7 TREE ADMIN. Second Review: (Approved as revised. I ID nied. nNot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I /Approved as revised. (Denied. [/Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application OFFICE COPY 441 City of Atlantic Beach . ;41/r800 Seminole Road,Atlantic Beach, FL 32233 -un`'` Phone: (904) 247-5826 Fax: (904)247-5845 Job Address: 2028 Beach Ave, Atlantic Beach 32233 Permit Number: 7 _0 007 Legal Description 15-93 09-2S-29E.114 N Atlantic Beach Unit No 3 PT E 100FT LOT 69A RE# Valuation of Work(Replacement Cost)$ 31,282.00 Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): New Addition Alteration Repair Mov- 11-0.• Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial •esidential • If an existing structure,is a fire sprinkler system installed?(Circle one : 'es No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Solar PV Electric Installation on roof of home Florida Product Approval# See attached specification sheets for multiple products use product approval form Property Owner Information Name: Matthew Rapp Address: 2028 Beach Ave City Atlantic Beach State Fl Zip 32233 Phone 904-806-4382 E-Mail mattrapp329@yahoo.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: A1A SOLAR CONTRACTING, INC Qualifying Agent:Joseph Peter Wilking Address 10418 New Berlin Road, Unit 223 City Jacksonville State Fl Zip 32226 Office Phone 904-468-7861 Job Site/Contact Number 904-545-6455/Heather Auton State Certification/Registration# CVC56771 E-Mail info(ca1 asolar.corn Architect Name&Phone# Engineer's Name&Phone# ROBERT MONTANARO 904-238-9167 Workers Compensation _ Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO OF COMMENCEMENT. (Signature of Owner or Agent including Contract r) (Signature of Contractor) Signed and sworn to(or affirmed)before me this 1 day of Signed a • sworn to(or affirmed)before me this Lih dy7 a�y(�of 3 -— ZO- , , by 1�1L1�th gape J' .t ' ?JO,by /� . C W\Y�-i- .. 'i o . ture �►" ala X A JADA t Q A ANNA JADA :�• ''`',fie.: :�•. MY COMMISSION#FF991573 MY COMMISSION#FF991573 EXPIRES May 11,2020 -- � / ,a,,, EXPIRES May 11,2020 (x07)398-0753 F$oidallo Ssvics.00m I[ Pec ✓ 1407)398111 S3 Flonaatiofa [ ]Personally Known Oft rsonally Known OR • [ roduced Identification W [ ]Produced Identification Type of Identification: Type of Identification: Doc # 2017149800, OR BK 18032 Page 609, Number Pages: 1 , Recorded 06/27/2017 at 09:03 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 •_NOTICE OF COMMENCEMa.NT .PREPARE IN DUPLICATE. Permit No. Tax Folio No. T state of Fior as County of 1x 1\i AL To whom it may concern: The undersigned hereby informs you that Improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following Information is stated In this NOTICE OF COMMENCEMENT. / Legal description of property being improved:l I/ i`�-C1.2 J ( ) U -6tZt-L-\ 'Jr NtT E IDU FT ( A Address of property being improved. Q V)5, AV e, At 1 Ca-tc_ 1�Ch . i L. 3222-21 General description of improvements: Solar PV Install Owner Mot ) .(:,\, G 11 Address a s �Za A\rt. „At ;c. 322 Owners interest in site of the improvement j DO °fb Fee Simple Titleholder Of other than owner) N A Name N;a Address N A Contractor A1A Solar Contracting.Inc. Address 10418 New Berlin Road.Unit 223,Jacksonville,FL.32226 Phone No 904-468.7861 Fax No. Surety(If any) N 4 Address Amount of bond S Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements Name A Address Phone No. Fax No Name of person within the State of Florida.other than himself.designated by owner upon.vhom notices or other documents may be served: \ 1 Name y . A Address Phone No. Fax No. In addition to himself.owner designates the following person to receive a copy of the Lienor s Notice as provided in Section 713.06(2)(b).Florida Statutes.(Fill in at Owners options. Name 14 A Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWN • Before me inn dey Ct DATE u ty C vas te ata p personaoy aaared Mrs••it arw e.ot�k Dthat bl ratemenn and laPidfN1A ANNA JADA are nue and accurate MY COMMISSION#FF991573 ,. EXPIRES May 11,2020 ' ( FiordaNdrery$ern ce.com kia39.8-0153 , Notary Pu- at large. • County or t1\A lift mComm y cO - tton ,n e.ps: \y 11] Personally Kno..n 1 or Produced Identrecat.n »L AlA Solar Contracting, Inc. Mail-JEA Solar Permit Approval #1163... https://mail.google.com/mail/u/0/?ui=2&ik=7ad5981b56&jsver=veU... OFFICE COPY A1A SOLAR Cathy Williams<cath williams alasolar.com> CON i N>C 1 I N G INCORPORATED J' v JEA Solar Permit Approval #1163 - 2028 Beach Ave - Rapp, Matthew Hyatt - A1A Solar 1 message Net Metering Program Mailbox <netmeter@jea.com> Mon, Jul 10, 2017 at 5:23 PM To: Jimmy Douglas<jdouglas@coj.net>, Rick Taylor<rataylor@coj.net>, Ricky Smith <rickys@coj.net> Cc: "Cathy Williams(cathy.williams@alasolar.com)" <cathy.williams@alasolar.com>, "Gutierrez, Edgar A. - Manager Customer Solutions" <gutiea@jea.com>, "Lundeen, Timothy M. - Manager System Analysis" <lundtm@jea.com>, Net Metering Program Mailbox <netmeter@jea.com> The size of this customer's PV system as submitted meets JEA's Tier 1 net metering requirements. Premises Rapp, Matthew Hyatt (904) 806-4382 2028 Beach Ave Jacksonville 32233 Contractor-AlA Solar Contracting, Inc. (904)468-7861; cathy.williams@a1asolar.com<mailto:cathy.williams@a1asolar.com> info@alasolar.com<mailto:info@alasolar.com> virginia.jada@a1asolar.com<mailto:virginia.jada@a1asolar. com> PV system information from application 32 panels 9.92 kW Roof mounted -fixed axis Dennis Fleming JEA DSM Coordinator 21 West Church St. T-12 Jacksonville, FL 32202-3139 flemdj@JEA.com<mailto:flemdj@JEA.com> voice 904-665-7077 fax 904-665-7386 Florida has a very broad Public Records Law. Virtually all written communications to or from State and Local Officials and employees are public records available to the public and media upon request. Any email sent to or from JEA's system may be considered a public record and subject to disclosure under Florida's Public Records Laws. Any information deemed confidential and exempt from Florida's Public Records Laws should be clearly marked. Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact JEA by phone or in writing. winmail.dat 10K I of 1 7/11/17,2:53 PM • Doc # 2017149800, OR BR 18032 Page 609, Number Pages: 1, Recorded 06/27/2017 at 09:03 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 ..JOTXCE OF COM ENCEPL.,ST OFFICE COPY .PREPARE iN DUPLICATE. Permit No.S O IRI / - O067 Tax Folio No. State of Florida County of bt.1\i kL To whom it may concern: The undersigned hereby Informs you that improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following Information is stated In this NOTICE OF COMMENCEMENT. fr�� ^n Legal description of property being improved:�t/��-`-12) t s) 1 `►E .. '. C IDUFT LT t Pb A Address of property being improved:y2(-1)C� ��� Ave . Air 1 1)cl'1'1�."(4 ( �.. 37?A3 General description of improvements: Solar PV Install Owner P^Q �\IN.t\I Address r h)i)CR t. 1 c. L x'- . -,522?)?.) Owner's interest in site of the improvement (-)() C)6 Fee Simple Titleholder(if other than owner) N A Name N I� Address • Contractor A1A Solar Contracting.Inc. Address 10418 New Berlin Road.Unit 223,Jacksonville,FL.32226 Phone No. 9O4468-7861 Fax No. Surety(if any) N A Address Amount of bond 3 Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name f\ A N Address y Phone No.. Fax No. Name of person within the State of Florida.other than himself.designated by owner upon•.vhom notices or other documents may be served: Name N A Address Phone No.. Fax No. In addition to himself.owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b).Florida Statutes.(Fill in at Owners options. Name n,n Address '4+1 Phone No. Fax No. Expiration date of Notice of Commencement!the expiration date is one t 1 i year from the date of recording unless a different date Is specified): THIS SPACE FOR RECORDER'S USE ONLY I OWN j 6 Mare ma this Tf day ct ] J�arE I C•u ty D vas—. tate• lord hit i. mthe y .:,.�x _i personally a*eared ` om'horsetr ano a rms mat.ii ta:aments and d ..' ere INIA ANNA JADA I are true and accurate 'c MY COMMISSION#FF991573 ,r`'a EXPIRES May 11,2020 -�•i�J • , (R) .odi6a 153 Fitdoaity$ervtce. Notary�� at Large.S o,' ,�.pT my corwn_ ton ex �� County or fi\A t peas: ei�t\t� /_ Personally Kno.,n Produced!denalicaton or -1117-- Lu L is Cava :Aa COMBIA3rmilimmilliP N z+,11 ,--,Ad03 33Idd0 SNOIlIaNOOaNvS1N3W3u,nlo3b oo 1VNOIIIGaV UOd SIIWU13d 33S H3V38 0IINV1IV d0 A113 33NVIldINO3 3000 UOd 03M31AEL rit o FRON W �, M t N re 41 p te+ #k a J a N c� Q.:� O = N I 0 N M 3 / Q ` a . z 0+ �a � � co 0 W Ili 31 it r, ... , I/ 1.ot 41,... . -s. cn r . . . . • i - ail...* 171:000:2... . at r M �. CO I • ., Yi _____ IL a M N 40 m 2 in �, -J o +' semLn v• M V G Ali II CO f m O iiiiiiLs.ir le, > , . . ► t I ,► *, 1 ,o A 4-7-_, 3 'ft 10'0 N 0 O. • U II e a 03 O 00 N m r I ———— NN N 0 o I M 0 0 `_ I M ri ‘ZrQ II V 6 � 2 oN I q//7 > i NX ri NL 1N C1 - d c c +-; to L LU tW 0 NL N c on > U lD2 > .. mv ° c vo u . vo v 0 0 cin m 0 Q Q Q Q 'Cc � vii v U Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOF IRONRIDGE 1495 ZEPHYR AVF,HAW'ARD,CA 94544 NAME Rapp 9.92 kW Residential;2028 Beach Ave. DATE 2017-07-09 Atlantic Beach, FL,32233 TOTAL MODULES 32 LOCATION Atlantic Beach, FL,32233 TOTAL WATTS 9,120 MODULE Jinko:JKM285M-60B(40mm) ATTACHMENT PTS 58 DIMENSIONS65.0"x 39.1"x 1.6"(1 mm x 992mm x 40mm) Load Assumptions Building Details WIND EXPOSURE D ROOF SLOPE 30 deg WIND SPEED 130 mph BUILDING HEIGHT 30 ft GROUND SNOW LOAD 0 psf RISK CATEGORY 1 ATTACHMENT SPACING 4.0 ft Engineering XR100 SPAN DETAILS(Portrait) MAXIMUM REACTION FORCES(Portrait) Roof Zone Max Span Max Cantilever Roof Zone Down Uplift Lateral 1 6' 10" 2'9" 1 289.00 -271.00 17.00 1 2 6' 5" 2'7" 2 289.00 -329.00 17.00 3 6' 5" 2'7" 3 289.00 -329.00 17.00 System Weight TOTAL WEIGHT 1526 lbs WEIGHT/ATTACHMENT 26.3 lbs DISTRIBUTED WEIGHT 2.7 psf RACKING WEIGHT 185.3 lbs Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 1 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOD /, IRONRIDGE 1495 ZEPHYR AVE,HAYWARD,CA 94544 Array Cols Rows Orientation Row Length Provided Rails Attachments Clamps Splices A 4 1 PORTRAIT 13' 3" 28'[2 x 14'1 8 10 0 13'3" 5'5" Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 2 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOF IRONRIDGE 1495 ZFPHYR AVE,HAYWARD,CA 94544 B 10 1 PORTRAIT 33' 6616 x 111 18 22 4 B 13 1 PORTRAIT 42' 10" 88'[8 x 11'] 22 28 6 42' 10" 10' 10" Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 3 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED R00= //r IRONRIDGE _ 1495 ZEPHYR AVE,HAYWARD,CA 94544 C 3 1 PORTRAIT 10' 22'[2 x 11] I 6 8 0 9' 12" 5'5" Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 4 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOF r' IRONRIDGE 1495 ZEPHYR AVE,HAYVVARD,CA 94544 D 2 I 1 I PORTRAIT 6' 8" 2212 x 11'] 4 6 I 0 I 6'9" 5'5" Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 5 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOF /Ai IRONRIDGE 1495 ZEPHYR AVE,HAYWARD,CA 94544 30 PV MODULE / RAIL - FLASHFOOT2 ROOF MEMBRANE BUILDING STRUCTUR Front View (Portrait) ATT/OMENT SON! PV MODULE .4111111111 RAIL �4VFLASHFOOT2 --- -ROOF MEMBRANE BUILDING STRUCTUR Note:The images displayed in this report are meant to represent one portion of the array.The use of a break line indicates that the array may continue on beyond that point. Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 6 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOF /lam IRONRIDGE 1495 ZEPHYR AVE,HAYWARD,CA 94544 Y SELF-DRIVING SCREW fil/ - RAIL - INTERNAL SPLICE INTERNAL SPLICE O O O I Splice Connection p ------ SIDE-FACING SLOT XR100 Clamp Detail PV MODULE /---- UNIVERSAL RAIL STOPPER FRAME FASTENING SLEEVE lI.IU.l.,.i._......1 p k FASTEN l4e111,i11r, inr -I/d _ OBJECT _:I'� PV MODULE UNIVERSAL FRAME UNIVERSAL OBJECTING - PV MODULE �" FASTENING, ' lrr OBJECT FRAME i`.`7) UNIVERSAL FASTENING I OBJECT N RAIL RAIL STOPPER PV MODULE SLEEVE FRAME Mid Clamp, Plan Mid Clamp, Front End Clamp, Plan End Clamp, Front FlashFoot2 Detail / 1 H,I 3s,. V - s ,z ,, I� : ./ E 5. w mom. 24-- Perspective 3Perspective View Plan View Front View Side View Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 7 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOF // IRON RIDGE 1495 ZEPHYR AVE,HAYWARD,CA 94544 0< 0 Ox - ma - 0 Q- > of 0 lei 0= =m= =0 0 2-- Of 0 e 4 OA 11 1 11 0 = =iii : :0 >0� 0 UFO Clamp • Grounding Lug * —� Fault Current Ground Path 1 Min 10 AWG Copper Wire* Bonded Splice (Rail Connection) *Grounding Lugs and Wire are not required in systems using Enphase microinverters. Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 8 of 9 Rapp 9.92 kW Residential; 2028 Beach Ave. Atlantic Beach, FL, 32233 PITCHED ROOF //r IRONRIDGE 1495 ZEPHYR AVE,HAYWARD,CA 94544 GROUP PART DESCRIPTION TOTAL QTY RAILS&SPLICES XR-100-132A XR100,Rail 132'(11 Feet)Clear 18 XR-100-168A XR100,Rail 168"(14 Feet)Clear 2 XR-100-SPLC-BD Kit,XR100 Bonded Splice 10 CLAMPS&GROUNDING UFO-CL-001 Kit,4pcs,Universal Module Clamp 19 GD-LUG-003 Kit,2pcs,Grounding Lug,Low Profile 3 UFO-STP-40MM Kit,4pcs,Stopper Sleeve,40MM,Clear 5 ATTACHMENTS FM-FF2-001 Kit,4pcs,FlashFoot 2(Mill) 15 FM-SQ-81-1W Kit,4pcs,Square-Bolt Bonding Attachment Hardware 15 Last updated by Robert Montanaro on 2017-07-09 08:54:36-0700 Page 9 of 9 _____ _, r.... ,_, z ,, .......... Ad00 301WW0 FRON LL c N r + N + ¢V- I Q, + Ja ' " _ � 0N � z cc N 4.4.. N O 9 d C Nm- - 4 114 CC 11111 Nilkii lottiotot-, ,44.000 -:' R Z t A '1ifia,pit ` o O r s. ..,�qA Sy.,y._ .`.:,:.win �, 7 rA t/1 , U co Z °' :1:,L • . -a� o 01 10 r� • 0 t • a n Q RI m Z cc 4 h M v • . N N E ,��' r A f rn = r N , J O _ Lll ► 4 ; t4 alP y � cc 40 ..,*" J CO . 11- V 111441041 o CO k, •N Q al CL 11/7 Ilk co __ ..,t-N .,` , ,, wi U QI .. CC CC W Mm O l-1 N M O X —. N N M 0 o Q O O u U M LD d- 00 CV R3 \ cc c Q i U U G. C O LL �, ! 2 •0 i lD o N t a.+ .. O r-I u1 .. Q, L aJ Oop > U C N N > ,n Y Q, N i rl. Oii • Y C bA U CO O L >' U r° N - = O v) o p v O ) o o c . > X c E z m 5 v ra Q 2 c 0 0 2 v) o'5 0 Q Q Q Q CC u. vMI Oj v U CD ° ir w LON Ad03 33IdIO2 P3 icIC 4 �*K cn cn N T O o o o M 0¢0 2 Q t J , E aP N v m , LLI C70 CD U jON r1 r J > azo N n O0 mU 410 O .. T 03 O -d G v Q vi 2 0 u f w C) N L N > � is 1 oza z °��° o ° a � z al d Q oz� o o — d u r ( III JDU �1 N ami m n G1 CD(W Y 0 f0 n N N R O ON Q ILt 4_a o' tV- C . U Im o a bO a Q F C C ', o Ufto LC4 Z Q OOc "' N _ PI-5- d I-- 0Qn> O O `.: O I ` • 1 g2. c8 aa.+ 0.PO \ ; Si tQQQN w R § m ".jaV M O •f < ,ryiiEE Om Q _ _, - © 1< 124 1 Wn U x =. ro y G >7 c co ," �,�- o .. 01 u, 0 U U Z Z Z Z Z < .<,1 5 5 f=// o : j g a m C. x 1 a} Q Q Q Q ° Q ° �+ c U c ' •1 j O ~ Z Z Z ,, Z Z =Pe _ c ' 1co REmNgv0 • . -.. LLce mJ ,ZL ,S aQ " o O cm � omN Q bc P--+ uo H U N , W 7 N ,- e co .- m W c E DWa ^ a E- i $' IQ & Uz _, mn ° o O�O V: cziT) N z U5 .. s W CC O 0 0 N N N al .'2 1 4 ;2- >— 1118 cola >- Id Z w z U D Z • K ' • LL • ct CI EI cc t W LL a • 1-_ • CC ZI- 0 Y Z d 0. ❑N Q.Q N a as w N 3 3 cZ7 z • ; ><c) • �I Z C� '`g . x ¢ z z ¢ _ • ? zEgcc • 1o00V wm z or ~ w m- co c oCei . o V W Z 6 1- • 0 Z U , • Z Z V Z ■ X W ❑ X CO ❑ X o ¢ w '' J WOM I I 1:12 „.. LL)5 a 0 y ■ = U m X Z 2 m a W Z Z i Z > UU' Q X O LL UU' D U w F a K Z a 0 I o w U `o w `o w 4 IIJflfl ! . ``- `y I f I V N ❑ W Z ❑ U Z ■ w > O m > O w O w > w w W ~ S W O = W oLLoaac9acna o Dow - z1- c9 � G0 • . M •S ✓ t°.I,�CO O © a H ., N CO a Y1 Ad03 ]3Idd0 1,..7i LG Innovation for Life's Good a Better Life 1011111111.1•06.m11.1111 M111111111 1111111111111111111111 IIIIIIIIIIIIIIMIMIIIIIIIIIIIIIIIIIIIIII s _ .L IIIINIM11111111111111 LGN eO N 2 LG310N1C-G4 LG's new module,LG NeONTM 2,adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires FAP PnOD'JCt to enhance power output and reliability.LG NeONTM 2 V demonstrates LG's efforts to increase customer's values D E CE \IY us ! rr� 60 cell beyond efficiency.It features enhanced warranty,durability, l f lntertek i i xU"64S'1 BSEN6r2IS performance under real environment,and aesthetic is„xm.°xaxv°,0w design suitable for roofs. Enhanced Performance Warranty •• High Power Output LG WOW"2 has an enhanced performance warranty. Compared with previous models,the LG NeONT"2 The annual degradation has fallen from-0.7%/yr to has been designed to significantly enhance its output 0.6%/yr.Even after 25 years,the cell guarantees 2.4%p efficiency,thereby making it efficient even in limited space. more output than the previous LG NeONTM modules. Aesthetic Roof Outstanding Durability G Ne0NT"'2 has been designed with aesthetics in mind; With its newly reinforced frame design,LG has extended thinner wires that appear all black at a distance. the warranty of the LG NeON''2 for an additional The product may help Increase the value of 2 years.Additionally,LG NeONT"2 can endure a front a property with its modern design. load up to 6000 Pa,and a rear load up to 5400 Pa. �•; Beer Performance on a Sunny Day Double-Sided Cell Structure LG NeONttNeONTM 2 now performs better on sunny days thanks The rear of the cell used in LG NeONT"'2 will contribute to to its improved temperature coefficiency. generation,just like the front;the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity.based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985,supported by LG Group's rich experience in semi-wiidurtor.LCD,chemistry.and materials industry We aucressfclly released the first Mono X.series to the market in 2010.which were exported to 32 countries in the following 2 years,thereaf ter.In 2013,1G NeON'"(previously known as Mono X®NeON)won"Intersolar Award':which proved LG is the leader of innovation in the industry. Ad03 33IJJ0 Enohase Microinverters Enphase M250 1 411 r, 4 q The Enphase M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage Cable, the Envoy Communications Gateway and Enlighten Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE - Optimized for higher-power - No GEC needed for microinverter - 4th-generation product modules - No DC design or string calculation - More than 1 million hours of testing - Maximizes energy production required and 3 million units shipped - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 dust, and debris Cable years [e] enphase' sA® ENERGY C US Ad®O 33W0 Engage Cable System and Accessories Enphase Engage Cable . P viqiwo 1 a ',,i01,A040:0)4114' The Engage TM Cable is a continuous length of 12AWG cable with pre-installed connectors for Enphase Microinverters. The cable is handled like standard outdoor-rated electrical wire, allowing it to be cut, spliced and extended as needed. The Engage Accessor1c complement the Engage Cable and give it the ability to adapt to any installation. FAST FLEXIBLE SAFE Quick installation - Simple design - No high voltage DC Large branch capacity - No additional cables - Reduced fire risk enphase. Cie c us AdOO 33I,dHO enphase TECHNICAL BRIEF [£'J ` NI " G v Equipment Grounding in an Enphase System Overview An Enphase Energy Microinverter System is the safest photovoltaic system available.The Enphase Microinverter System is safer for service personnel, safer for fire fighter personnel, and less prone to the fire hazards that come with higher voltage DC string systems. Many of these safety advantages are widely known: - DC voltages are maintained at low, safe levels - Conduits and conductors are de-energized when the main breaker is shut-off - Enphase Microinverter Systems are free of DC arc-fault hazards and arc-fault requirements However, one advantage that is rarely discussed is the high level of ground bonding that exists in an Enphase Microinverter System. Each microinverter in an Enphase system is bonded to ground through the Enphase Engage cabling system. The Engage Cable provides a robust grounding path to each microinverter, and when properly bonded to racking and to module frames, provides for robust equipment grounding to this equipment, also. When the microinverters, racking, and modules are properly bonded together with listed and approved grounding hardware, the equipment grounding is provided through the microinverter cabling system. This provides a significant cost savings to the labor and balance of system costs. Enphase Grounding and the 2011 National Electrical Code Equipment Grounding and System Grounding Requirements The Enphase M250, M215 (M215-60-2LL-Sxx-IG), and C250 fourth generation microinverters meet the requirements of the National Electrical Code Article 690.35 for Ungrounded Photovoltaic Power Systems. NEC 690.35 allows for photovoltaic power systems to be installed with ungrounded photovoltaic source and output circuits. Systems that meet the requirements of NEC 690.35 are exempt from the system grounding requirements of NEC 690.41 System Grounding. The NEC calls out two distinct types of grounding—equipment grounding and system grounding. Equipment grounding provides for the grounding of metal equipment and enclosures and is generally provided for with equipment grounding conductors (EGCs). System grounding provides the primary grounding path between a grounding electrode(i.e., ground rod or ufer)and a grounded system. System grounding requires the installation of a grounding electrode conductor(GEC). In an Enphase system,the DC conductors are not bonded to ground and the microinverters do not require a GEC, but do require an EGC for equipment grounding. The term ungrounded is somewhat misleading because ungrounded photovoltaic systems are still required to have equipment grounding provided to the metal frames, equipment, and enclosures in the system, but they are not required to meet the requirements for system grounding. Because of their unique construction, Enphase Microinverters do not require installation of a GEC to the microinverter enclosure. Other photovoltaic systems that do bond the DC conductors of the photovoltaic source and output circuits to ground must meet the installation requirements for the GECs as called out in NEC 250.64,which requires that the GEC be continuous and protected against damage. The GEC must also be a minimum #8CU conductor, as required by NEC 250.166 for those systems. 1 ©2014 Enphase Energy Inc.All rights reserved. December 2014 AdOO 301AA0 Equipment Grounding in an Enphase System Meeting the Requirements of NEC 690.35 Ungrounded Photovoltaic Power Systems Enphase Microinverters meet the requirements of NEC Article 690.35 for Ungrounded Photovoltaic Power systems. The article states: 690.35 Ungrounded Photovoltaic Power Systems. Photovoltaic Power Systems shall be permitted to operate with ungrounded photovoltaic source and output circuits where the system complies with 690.35(A)through (G). (A) Disconnects. In an Enphase system the AC and DC connectors are the disconnecting means. (B) Overcurrent Protection. In an Enphase system,the AC circuit breaker or fused disconnecting feeding the branch circuit provides overcurrent protection for the inverter output circuit.As per 690.9(A) Exception (b), overcurrent protection is not required on the DC conductors. (C) Ground Fault Protection. In an Enphase system, ground fault protection is provided in the microinverter. In the Enphase Microinverters with integrated grounding,the ground fault protection is provided by a ground fault sensing circuit. (D) The DC conductors must be PV Wire.The DC conductors in an Enphase Microinverter are PV Wire. (E) Allowed for use in ungrounded battery systems (F) Labelling.The Enphase Microinverters are labeled as specified. (G) Listing. The Enphase Microinverters are listed for use in an ungrounded photovoltaic system. 3 ©2014 Enphase Energy Inc.All rights reserved. December 2014 Datasheet AdOO 331J10 AA IRONRIDGE Flush Mount System O I y IIIIMLL---- Built for solar's to !aheSt roofs IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified AMAll components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. aClass A Fire Rating Design Assistant Certified to maintain the fire resistanceEt Online software makes it simple to rating of the existing roof. create, share, and price projects. E. UL 2703 Listed System 20-Year Warranty Meets newest effective UL 27030 , Twice the protection offered by standard. competitors. Tech Brief IRONRIDGE Ad0O 331HH0 FlashFootTM Rapid & Secure Solar Attachments IronRidge FlashFootTM is an all-in-one solar mounting product for composition shingle roofs that eliminates the need for separate standoffs, flashings, and L-feet. Flash Foot incorporates a number of structural and waterproofing features to securely attach IronRidge AMA to roof structures, while also protecting against water intrusion and weather damage. Dual Mechanical Seal At the core of the FlashFoot,a pre-installed rubber bushing forms a dual mechanical seal,with its exterior compressed against the cavity of the L-foot and its interior tightly wrapping around the shaft of the lag bolt. .lea c r:. • i � I Load Distribution Plate A solid metalP late below the L-foot increases the FlashFoot's structural strength and prevents any deformation of the flashing during installation. Water Shedding Design A wide flashing layer combined with an elevated sealing platform maximizes the mo with IBBCCandd IRC SAP Certified FlashFoot's water shedding ability. . ES Tech Brief Installation Overview Tools Required: tape measure. chalk line. stud finder. roofing bar, caulking gun with an approved sealant, drill with 1/4" bit and 1/2" socket. • - - 3rd course �--Rafter 2nd course I I I I lstmucse i € 3 Locate rafters and snap vertical and horizontal lines Slide flashing, between 1st and 2nd course, so the to mark locations of flashings. Drill 1/4- pilot holes. top is at least 3/4" above the edge of the 3rd course then backfill with an approved sealant. and the bottom is above the edge of the 1st course. Line up pilot hole with flashing hole and insert lag The FlashFoot is now installed and ready for bolt through bonded washer, L-Foot, and flashing. Iron Ridge Rails. With provided L-foot fasteners pre- Tighten lag bolt until fully seated. loaded into rails, drop rails into open L-foot slots. Testing & Certification FlashFoot is certified for compliance with the International Building Codes (IBC) & International Residential Codes (IRC) by IAPMO-ES. Mechanical testing conformed to the standard for Testing and Analysis of Joist Hangers and Miscellaneous Connectors (EC002-2011), and rain testing conformed to the Underwriters Laboratory Standard for Gas Vents (UL 441-96 Section 25). Lag pull-out(withdrawal)capacities(lbs)in typical r oof lumber(ASD) Specific Gravity 5/16"Shaft,3"Thread Depth Douglas Fir,Larch .50 798 Douglas Fir,South .46 705 Engelmann Spruce,Lodgepole Pine(MSR 1650 f&higher) .46 705 Hem,Fir .43 636 Hem,Fir(North) .46 705 Southern Pine .55 921 Spruce,Pine,Fir .42 615 Spruce,Pine,Fir(E of 2 million psi and higher grades of MSR and MEL) .50 798 &V W%.Amok.Wood wwx NM 2005.Tett.11.2k 11.3.2A.Nobes'.I)rh..d mN M s.nbodbd n.W..,ad,e,seuNel,o0 m,000..6 8.IBC for,ea,..d edge M,a„cee ©2014 IronRidge,Inc.All rights reserved.Visit www.ironrldge.com or call 1-800-227-9523 for more information.Version 1.03 ZAIRE. Datasheet XR Rails XR10 Rail XR100 Rail XR1000 Rail Bonded Splices i i --,........................5._ `_'"'....5 __`'fir"'` A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear& black anod.finish • Clear& black anod.finish • Clear anodized finish • Forms secure bonding Clamps & Grounding UFOs Q Stopper Sleeves Grounding Lugs Microinverter Kit -moi - - :4 aill..rmia.v . _ L ,_ ........._ _ . _ Universal Fastening Objects Snap onto the UFO to turn Connects array to Mount MIs or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. • Fully assembled & lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • 6 different sizes • Single tool installation • Kit comes assembled • Clear& black finish • Clear& black anod.finish • Mounts in any direction • Listed to UL 2703 Attachments FlashFoot Bonded L-Feet Standoffs Ili 1 / f II 1 , Anchor, flash, and mount with Drop-in design for rapid rail Raise Flush Mount System to various all-in-one attachments. attachment. heights. • Ships with all hardware • Bonding hardware included • Works with vent flashing • IBC & IRC compliant • Forms secure rail connection • Ships assembled • Clear& black anod. finish • Certified with XR Rails 4"and 7"Lengths Resources -- . — Design Assistant 10 ♦t NABCEP Certified Training Go from rough layout to fully '�' Earn free continuing education credits, engineered system. For free. 4 > while learning more about our systems. Go to IronRidge.com/design Go to IronRidge.com/training ©2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.10 ,`I_ Equipment Grounding in an Enphase System Equipment Grounding Requirements for an Enphase System In a system with fourth generation Enphase Microinverters, the requirements for providing a GEC to the microinverters is removed, and only equipment grounding is required. In these systems, it is reasonable and safe to provide the equipment grounding to other photovoltaic system components through the Enphase Engage cabling. NEC Article 690.43 Equipment Grounding specifies that all exposed non-current-carrying metal parts of PV module frames, electrical equipment, and conductor enclosures shall be provided with equipment grounding. 690.43(C) Structure as Equipment Grounding Conductor allows for equipment to be used as the equipment grounding conductor in a photovoltaic system. Specifically, "Devices listed and identified for grounding the metallic frames of PV modules or other equipment shall be permitted to bond the exposed metal surfaces or other equipment to mounting surfaces." The devices listed and identified for grounding the equipment may be stand-alone grounding components or UL-2703 listed mounting hardware. In an Enphase Microinverter System, if the microinverters and modules are bonded to the racking assemblies with the use of listed and approved grounding clips or grounding components, the equipment grounding conductor provided to the microinverters through the Enphase Engage Cable may also be used to ground the other photovoltaic system components. Equipment Grounding Provided through Enphase Engage Cable 1 ' • If Grounding Clips or UL2703 Listed Hardware Bonding All Metal Equipment **Always check with your Authority Having Jurisdiction about your proposed grounding methodology prior to installing the system. 2 ©2014 Enphase Energy Inc.All rights reserved. December 2014 Enphase Engage Cable System I!DATA ,..� CABLE TYPES/ORDERING OPTIONS Voltage Connector Spacing PV Module Orientation Model Number #Connectors' Weight" 240 VAC.4 conductors 1.025 meter(40") Portrait ET10-240-40 40 40 lbs 240 VAC.4 conductors 1.7 meter(67") Landscape ET17-240-40 40 45 lbs 208 VAC.5 conductors 1.025 meter(40") Portrait ET10-208-30 30 30 lbs 208 VAC, 5 conductors 1.7 meter(67") Landscape ET17-208-30 30 35 lbs 'additional lengths availab'e through Enphase authorized distributors."weights are approximate w.. CABLE SPECIFICATIONS Description Rating Cable temperature rating 90°C(194°F)wet/dry Cable insulator rating THWN-2 UV exposure rating UL 746 C. Fl Conductor size 12AWG Compliance IEC 60529 IP67,CAN/CSA 22.2 No.21, 182.3.UL 486A/B,514C,6703,and 9703 Cable rating TC-ER Cable Diameter 1.25 cm(0.49") Minimum bend radius 12 cm(4.75") 10.., .x . ,m.. .I.«e...,,.,V.H8.R..0... .1. , .. • .. . ENGAGE ACCESSORIES --. Branch Terminator „.....e.:-'›lDisconnect Tool .�'-t;" '�• One terminator needed per branch � ' Plan to use at least one per lr-� circuit %%�lizpi, installation ET-TERM-10(sold in packs of 10) 4 ET-DISC-05(sold in packs of 5) Watertight Sealing Cap Cable Clip One needed to cover each unused ----- Many needed to fasten cabling , connector on the cabling 10.1111---- to the racking or to secure looped ���!% ET-SEAL-10(sold in packs of 10) cabling ET-CLIP-100(sold in packs of 100) Engage Coupler I Used for splicing two power cables within an array ET-SPLK-05(sold in packs of 5) To learn more about Enphase Microinverter technology, ' enphase visit : :. _ ,l',)2013 Enphase Energy.All rights h^icr'(A.All ttadt3r'.arks or brands in'ht'.,h.;-$r'i:nt are rogob red by their r04[cave:mnCr En phase®M250 Microinverter//DATA INPUT DATA (DC) M250-60-2LL-S22/S23/S24 Recommended input power(STC) 210-300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 9.8 A OUTPUT DATA(AC) 42)208 VAC @240 VAC Peak output power 250 W 250 W Rated(continuous)output power 240 W 240 W Nominal output current 1.15 A(A rms at nominal duration) 1.0 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range* 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% CEC weighted efficiency, 208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted, reference EN50530) 99.4 % Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 2.0 kg Cooling Natural convection-No fans Enclosure environmental rating Outdoor- NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 'Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, rel enphase® visit enphase.com L JENERGY ©2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. LGNeON 2 LG310N1C-G4 Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Module Type 310 W Cell Vendor LG MPP Voltage(Vmpp) 32.8 Cell Type Monocrystalline/N-type MPP Current(Impp) 9 45 Cell Dimensions 156.75 x 156.75 mm/6 inches Open Circuit Voltage(Voc) 40.4 e of Busbar 12(Multi Wire Busbar)• Short Circuit Current(Isc) 9.96 Dimensions(L x W x H) 1640 x 1000 x 40 mm Module Efficiency(%) 18.9 64.57 x 39.37 x1.57 inch Operating Temperature(°C) -40-+90 Front Load 6000 Pa/125 psf • Maximum System Voltage(V) 1000 Rear Load 5400 Pa/113 psf• Maximum Series Fuse Rating(A) 20 Weight 17.0±0.5 kg/37.48±1 1 lbs Power Tolerance(%) 0-+3 Connector Type MC4,MC4 Compatible.IP67 •STC(Standard Ten Condemn)Irradiance 1000 Wim'.Module Temperature 25.C,AM 1.5 IP67 with 3Diodes •The nameplate power output is measured and determined by LG Electrons at rts sok and absolute d,octan lUnCtIOn Box Bypass I•.ttyp,talchange m module officiencvat 200 Mir'm relater to 1000 Wlm'n-70% Length of Cables 2 x 1000 mm/2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum -- Electrical Properties(NOCT*) Module Type 310 W Certifications and WarrantyMaximum Power(Pmax) 226 Certifications IEC 61215,IEC 61730-1/-2 MPP Voltage(Vmpp) 300 IEC 62716(Ammonia Test) MPP Current(Impp) 7 54 IEC 61701(Salt Mist Corrosion Test) Open Circuit Voltage(Voc) 37 4 ISO 9001 Short Circuit Current(Isc) 8 03 UL 1703 •vet'•r,,,,,,,t 0,-eraong Cell Temperature)Irradance 800 W!m'ambrent temperature 20•C.vend speed i m/: Module Fire Performance(USA) Type 2(UL 1703) Fire Rating(for CANADA) Class C(ULC/ORD C1703) Dimensions(mm/in) Product Warranty ___12 years Output Warranty of Pmax Linear v.aria(Ity' •1)1st yew 98%2)After 2nd year 0 6%p annual degradat on.3)83 6%for 25 yews :,...L.7.,:: ) Temperature Characteristics ' )"-j � ImJ NOCT 46*3°C I rat,,. Pmpp -0.38%/°C• r..... o .. o.. ....«.. x r.a .. Voc -0.28%/°C Isc 0.03%/°C ! '"a""", ° y Characteristic Curves - l -'' 11 1.00,1d I - ,, / \ nmu,:00W / .:.«.'",-„ . 1 i ?.i 000 S. 1000 '50p :ora :500 1000 J... 4000 4..).. - 1/ ai I. es t .. Id z I,0 —._- : a 4 — ..r,nil0011111111111111111101111 i ka....o.�, 11:1111111111111111111111111110111111: ap .. 0 ., n r. •'he d sin",e between the tente•of the mounting/grourd'ng hole: 1_-7 L/�► North America Solar Business Team Product spe:-f.tatrons are sube:t to(rangewthout no; • � a V LG Electronics U.SA Inc 0S.N2-60.C-0-h-/N-50411 ,Nl tiles Good 1000 Sylvan Ave,Englewood CliffsN!07632 •11{ Copyright R0 20'5 LG Flectrc',cs.Ali rrghL reserved Innovation fora Bette,I,', •r Contact'Ig solar[llge coin 01/04/2015 wwwlgsolarusa corn .j •�