Loading...
1775 ATLANTIC BEACH DR - SFR PERMIT , f` CITY OF ATLANTIC BEACH � �' 800 SEMINOLE ROAD Old yr - ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0047 Description: new single-family home Estimated Value: 332731.5 Issue Date: 7/10/2017 Expiration Date: 1/6/2018 PROPERTY ADDRESS: Address: 1775 ATLANTIC BEACH DR RE Number: 169505 1480 PROPERTY OWNER: Name: RIVERSIDE HOMES OF N FL Address: 414 OLD HARD RD STE 502MATTHEW ROBERTS ORANGE PARK, FL 32003 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: RIVERSIDE HOMES OF N FL Address: 414 OLD HARD RD STE 502 MATTHEW ROBERTS ORANGE PARK, FL 32003 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. sIAN City of Atlantic Beach APPLICATION NUMBER r9 Building Department (To be assigned by the Building Department,) 800 Seminole Road C� S1� , 00 c _I 0 Atlantic Beach, Florida 32233-5445 � �y Phone(904)247-5826 • Fax(904)247-5845 -251,1> E-mail: building-dept@coab.us Date routed: 0lP ' to I City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: ti +S- A un-v L 14aCIA OD TDepartment review required Ye No CI u �^ ildin -, '\. Applicant: , Q,�S►d•,� N1,Q,S (Plan Tree Administrator Project: 1\.t,v3 S‘(\ \ L---Ca fY\t 1\' \1 U(v\4_ (--Pub , (Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI TION STATUS Reviewing Department First Review: I Approved. ❑Denied. . Not applicable (Circle one.) Comments: 0 r BUI % G v PLA • •.1 : ZONINGat / 7 Reviewed by: Date: t7 t� TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denie ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I f Approved as revised. ❑Denied. . ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 01...up„, City of Atlantic Beach Building Department APPLICATION NUMBER 800 Seminole Road (To be assigned by the Building Department.) w -0 Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 �� I"� "7�;�1L%' E-mail: building-dept@coab.us City web-site: http://www.coab.us Date routed: 0 Co I ca 4 APPLICATION REVIEW AND TRACKING FORM Property Address: I +S A un-V L Q,Q.Ch De.artment review required Yes No Building Applicant: l J -r S,1 L \ V L Pl.•••-. ; Tree Administrator Project: r(\,6,3 S1 j \ t_-_fa m t ,\ 0,'vl CPubt c Works ("1:;ublic Utilitie Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATIO STATUS Reviewing Department First Review: frpproved. ['Denied. . (Circle one.) C ['Not applicable Comments: BUILDING PLANNING &ZONING Reviewed by:�is�tl. /�l/'� / Date: �g,7 TREE ADMIN. I Second Review: QApproved as revised. []Denied. . ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. Denied. . ❑ ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 1 s=-1`pr City of Atlantic Beach r� ��� BuildingDepartment APPLICATION NUMBER �_. T. P (To be assigned by the BuildingDepartment.) �� 800 Seminole Road � Atlantic Beach, Florida 32233-5445I c DOL Phone(904)247-5826 • Fax(904)247 43 0 5 2017 [.1 '� ' ' \,....71,1)S E-mail: building-dept@coab.us Date routed: D(p I tya. City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 1.-S A-'an-M L °,Qct Lh Department review required Yes No ^ ildin Applicant: 1 j �.�(S��,,(,. L lv DA,Q,S PI�i Tree Administrator Project: i\t,0 S1 f\fl�\ k\l \(\ M -uonc or Public Utilitie Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. . ❑Not applicable (Circle one.) Comments: "tee 44,40 're BUILDING PLANNING &ZONING Reviewed b Date: as" TREE ADMIN. �, Second Review: °Approved as revised. ❑Denied. . ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: °Approved as revised. °Denied. . ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 si-ty r,,, City of Atlantic Beach :is t0 Building Department APPLICATION NUMBER 1� 800 Seminole Road (To be assigned by the Building Department.) 5 v �� Atlantic Beach, Florida 32233-5445 L, 3 :..,...i c Phone(904)247-5826 • Fax(904)24 5 ��"�'� , oo`� ��;3>%' E-mail: building�iept@coab.us ,` City web-site: http://www.coab.us SUN 0 5 2017 Date routed: 0(p I D7 1 �� if APPLICATION REVIEW AND-TRACKING FORM Property Address: 111'.S- A- an-V L Q_Qyx L`,\ Department review required Yes No Applicant: 6, A.t, oD Ii S CPI Ildin Tree Administrator Project: i\t),_.) S‘ \t_-_cam t. `\ 0 m.= u c ork"" Public Utilities Public Safety Fire Services Review fee $ -CO Dept Signature _ Other Agency Review or Permit Required Review or Receipt of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept.of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ODenied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING t / Reviewed by: v( -------- Date:(,;/(7(7 TREE ADMIN. Second Review: []Approved as revised. ❑Denied. . ❑Not applicable P _WORKS Com nts: PUBLIC UTILITIES 6o - S--/7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: QApproved as revised. ❑Denied. . ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 1- ,;.51-. ./t,^. A CITY OF ATLANTIC BEACH iii,., 1 �, - r ..,_,;:, : , !? PUBLIC UTILITIES 1200 Sandpiper Lane �1 ATLANTIC BEACH,FL 32233 (904) 270-2535 or (904) 247-5874 NEW WATER/SEWER TAP REQUEST Date: (p— 5 -17 Project Address: / IN Ihl ile.i 0 14 No. of Units: Commercial Residential ✓ Multi-Family 3 '' New Water Tap(s) & Meter(s) Meter Size(s) /,../ New Irrigation Meter V Upgrade Existing Meter from to (size) 3 " New Reclaim Water Meter7 Size 4 New Connection to City Sewer Name: Applicant Address: City: State: Zip Phone Number: Cell Number: Email Address Fax: Signature: (Applicant) CITY STAFF USE ONLY Application# ,$ — 17 - 00 :/7 Water System Development Charge $ It I go t 00 Sewer System Development Charge $q,0 SO. OD ni C C Water Meter Only $ / $ Reclaim Meter Only $ 185.60 Water Meter Tap $ (notes) Sewer Tap $ Cross Connection $ 50, 0?)( Other $ TOTAL $5, (0100 .$5, (,11L00 APPROVED: Kayle Moore, PE ,►.A__ (Deputy PW Director or Authorized Signature) ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES ii CAN BE ASSESSED BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH OFFICE COPY 800 Seminole Road,Atlantic Beach, FL 32233 Office (904)247-5826 Fax(904)247-5845 Job Address: 1775 Atlantic Beach Drive Permit Number: f--65‘1 —00 -1-4 Legal Description Lot 37 Atlantic Beach Country Club Unit 2 64-132 08-2s-29E.162 Parcel# 169505-1480 Floor Area of Sq.Ft. S-q.Ft Valuation of Work$ 600,00() Proposed Work heated/cooled 2710 non-heated/cooled 549 Class of Work(circle one): 41115 Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial If an existing structure,is a fire sprinkler system installed? (Circle one): -es No /A Florida Product Approval#For multiple products use product approvaUform C� I �; `� 1_ SFR D, , '�_� _..._---�w---�- �..-, .., Describe in detail the type of work to be performed:New construction- P JUN - 22017 Property Owner Information: -- - Name: Riverside Homes of N.FL Address: 1775 Atlantic Beach Drive City Atlantic Beach State FL Zip 32233 Phone 904-503-7055 E-Mail or Fax(Optional)lbishop@myriversidehome.com Contractor Information: Company Name: Riverside Homes of North Florida, Inc. Qualifying Agent: ni:lMatthew Roberts te FL Zip 32223 Address:12276 San Jose Blvd.,Ste. 120 City JacksonOffice Phone 904-503-7055 Job Site/Contact Number_Same Fax#N/A State Certification/Registration# CBC1254135 • Architect Name&Phone#Cronk Duch Arch 904-626-3452 Engineer's Name&Phone#Hulsberg 904-886-2401 Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address commenced Applicationaca hereby rm t amade t all work will be pe f performed work and meet the standards of all lations as laws regula. I ting constructithat no on in rk thir installation jurisdiction his permit becomesrior othen ull issuance period work isd f menced.ot I understand trhat separate permits must be secured for ElectricualpWork,l Plumbing,Signs,a Wells,Pols,,Fx urnacemons, t s,time Tanks and Air Conditioners,etc. WARNING TO OWNER: OUNRYFOAILURREYTNOGRTEVCORD UR IMPROVEMENTS OF EMENTS COMMENCEMENT MAY RESULTYOUR CONSULT TO YOUR PROPERTY. IF YOU INTEND EFO00�OBTAIN YOUR NOTICE OF WITH YOUR LENDER OR AN ATTORNEYMMENCEMENT. his tI herebyorktwy that I have read h wether s pe this ere ntion or not.d The grantingw he o a perto be mit dose and orrect. All of presume to give authorvisions ity to vlaws iolate ate o cancel the provisioordinances governing ns type of work will be complied with whether spec)ted f p of other federal,state,or local law regulating construction or the performance of construction. Signature of Owner Signature of Contractor ,�n„4 -.pj ) �� ? Print Name 1 D "Z Print Name r11�Y,J� "�"" Sworn to and subscribed before me 20 qSworn to and subscribed before me ,20 ).) tai tO Day of this `O Day of , " • PY----6 otary P41No Pub is Revised 01.26.10 ,•io• «`1= LINDSEY M.BISHOP LINDSEY M.BISHOP _ - Notary Public-State of Florida .` r X0 . ` , = Notary Public-Stale of Florida "ss. .o`` Commission#FF 946204 •'.- Commission #FF 946204 My Comm.Expires Jan 19.2020 =°; ��S 04i.- Comm.Expires Jan 19,2020 '--•.„,,,.,, _ _ s i OFFICE COPY (-- SITE PLAN LOT 37 AS SHOWN ON PLAT OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67, PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. S' 1.BEADINGS ARE BASED ON THE aZNTERLINE OF ATLANTIC BEACH DRIVE AS BONE 532.41'1e'E. 2.DRAINAGE ELEVATIONS SHOWN HEREON ARE BASED OR NAND 196& 3.THE LANDS 5HOWE4 HEREON LE w1NN FLOOD ZONE'1C AS DEPICTED ON THE FLOOD INSURANCE RATE MAP GRAPHIC SCALE (F'IR'M')COAIWNITY NUMBER 120077.PARE.NUMBER ORDER.DATED.JUNE 3.2013.THE FLOOD ZONES 910WN ON LINE TABLE M6 S7E PLAN ARE SCAID co.di INE F.E ALA•FIRM.MAPS AND ARE FOR REFERENCE ONLY.THE FIRM. IN ORMAT10N AND OEUNEAT(N'S ON THIS 91E PUN ARE VALID ONLY FON DALES UP TO AND INCLUDING THE DATE ID 30 UNE DIRECTION lP3NGTH OF TMS SITE PUN.MERE MAY HAVE BEEN SVBSEOUENT REASONS AFTER THIS DATE THAT WLL SUPERSEDE SAD 30 0INFORMATION.INOARIES 91010.0 BE MME TO THE CGL.ANITYS PL000 PLANE MANAGEMENT REPOSITORY. 11 C) S3Y4I'IB'E 10.92 DEPARTMENT OF PUBLIC WORKS DUVAL COUNTY. ( 4.F.000 MAPS REFERENCED HEREON ARE BASED ON NAND 1986. L2(P) 532'41'16'E 0.59 '+°T UNDERtltOJNO FOUNDATIONS OR U1EITIES&NO IYPROVDIENTS OTHER THAN THOSE SIGMA MERE LOCATED LARDER THE SCOPE OF THIS SITE MAN. 13(P) S3T'41'16 E 60.00 B.ADOTgNS,DELETIONS AND/OR ANY MITTEN INFORMATION ADDED TO TNS MAP AND/OO REPORT IS PROHIBITED AND IS NOT AUTHORIZED BY THE STONING SYRNENOR. IN FEET 7.TNS MAP IS INTENDED TO BE KEYED AT A SCALE OF 1'-3O OR SMALLER. B.FATE ED k PATIOS DEPICTED AS EXTENDING INTO THE BUEDOIO RESTRICTION UNITS MUST REMAIN UNCOVERED& NOT ENCLOSED. ) 1 inch = 30 ft. 9.UPLAND BUFFERS ADJACENT TO WETLANDS ARE TO REMAIN NATURAL.VEGETATIVE,AND UNDISTURBED. 10.DIMENSIONS ARE IN FEET AND DECIMAL PARTS THEREOF. 11.THIS SITE PLAN IS ONLY FON THE LANDS AS DESCRIBED.IT IS NOT A CERTIFICATE OF BILE.ZONING. EASEMENTS OR FREEDOM OF ENCUMBRANCES. DENOTES PROPOSED CONCRETE 12.THIS STE PUN WAS NOT INTENDED TO DELINEATE CR DEFINE ANY WETLANDS ENVNONMENTA LY SENSITIVE AREAS.VALOUR HABITATS CR JURISDICTIONAL LINES OF ANY FEDERAL.STATE.REGIONAL CR LOCAL AGENCY. BOARD.AND COMI/SSON OR OTHER ENTITY AND ANY LIABILITY RESULTING THEREFROM IS NOT TIE RESPDNSIBIUTY DENOTES PROPOSED PAVERS OF THE UNCERSIGNED. 13.UNLESS A COMPARISON IS MADE.MEASURED BEARINGS AND DISTANCES ARE DENTICAL w1 PLAT VALUES. 14.TNS STE PLAN IS BASED ON INFORMATION AS PROVIDED BY THCLI E ENT. ❑ DENOTES CHEMICAL TOILET 15.BUILDING AND IMPROVEMENTS F ANY.AS DEPICTED HEREON ARE P°mENDI°R"R TO TIE PARCEL PROPERTY LINES. ALL BUILDING DES ME SHOWN TO THE FOUNDATION. r'N- DENOTES FUTURE 4w TREE 16.PLEASE REFER TO THE PUT FON ADDITIONAL ITEMS THAT MAY AFFECT THIS LOT. 17.M$IS NOT A BOUNDARY SURVEY. Is.PUBLIC SIDEWALKS DEPICTED HEREON ARE BASED ON THE CONSTRUCTOR PLANS THEY ARE SNOW FOL X DENOTES TREE TO BE REMOVED INFORMATIONAL PURPOSES PLY AND ARE NOT TO 13E RELIED UPON FOR CONSTRUCTION. FOR CORRECT LOCATION AND/OR ONDNSGNS REFER TO THE MOST CURRENT SET OF CONSTRUCTION PLANS THERE IS A MAMMA 2% SLOPE ON AL SIDEWALKS.AU.SIDEWALK AND FUTWOFa(SIAL AT A MNIYW,MEET CURRENT DUVAL COUNTY AND ADA STANDARDS.CROSS SLOPES SHALL BE NO YORE THAN 2%THE PORTION OF THE SDEWALN 1W901 CURVE TABLE TRANSVERSES THROUGH THE DRIVEWAY APRON SHALL ALSO MEET TNS REQUIREMENT.ALSO.PLEASE NOTE THAT UTILITIES(PETER BOXES.VALVES,ETC.)SHALL NOT BE INSTALLED w1HIN THE SDEWALK. CURVE RADIUS ARC LENGTH CHORD DIRECTION CHORD LENGTH DELTA 19.DRAINAGE STRUCTURES DEPICTED MAY VARY IN SIZE REFER TO ENONEERING PLANS FOR CORRECT DIMENSIONS CT(P) 400.00 59.63 S3637'31'E 59.58 8'32'31' 20.A/C T PADS E TMO 1 MAINT iN 3� AWAYFROM ANY PROPERTY LINE Ate CAN NOT ENCROACH INTO A DRAINAGE MD \ c' \c), \ Lo \r \ ,3z qp. o°: \ •\5-5C 1 `Y 1 �\\\ 7.50' 0fA,*\ ��� \ , / \ � \ \ 7.50' � D �/ Tau % o. \ 't 4/* 76 l',..51,44. \• ^1` 16 J < �yA+ �E ' " k •/Z ` Qrt �a �. ii. .qt. •V_ a9 4* jam, 7.5DG� `rL�� SOS • ,� 7''i, `t,. y�•r C) ,'s, e ..-w „c, cm) o of 20.50• > \ .h 9) ASI LAL ��1 Iia 7.50' 1> t 6T - + A x,...),,,..:‘,1_., JLJ 3A A 29�t,z61...., cm( \ `> \%',0:\ NA SOD BREAKDOWN a.l.'ir"• TOTAL LOT AREA 7,112 Sq.Ft. \\ R/W TO CURB 625 Sq.Ft. •ISETBACKS" \ GROSS SOD AREA 7,737 Sq.Ft. FRONT-20 FEET FROMBMX FACE OF GARAGE TO BX OF RIGHT OF WAY AND \ \ IMPERVIOUS COVERAGE 2FnucTTDNS 15 FEET FROM BUILDING FACE OR PORCH TO BACK OF RIGHT OF WAY; FOUNDATION SLAB 2.093 Sq.Ft. EXCEPT CORNER/KUBLE-FRONTAGE LOTS.FON RIICN NE NON-ADDRESS \ \ WPDtN10U5 Sq.FL LOT Sq.FL % DRIVEWAY 691 Sq.Ft. FACE TO BACK OF BIGHT OF WAY. FRONT/90E M91.UY YARD SNAIL BE 10 FEET FROM GARAGE OR BUILDING \a \ 3,354 Sq.Ft. 7,112 Sq.Ft. 47.2% LEAD WALK 33 Sq.Ft. SIDEWALK AREA 0 Sq.Ft. NOTE: \ �`.)'\ A/C PAD(S)Q GARAGE B Sq.Ft. PER ARB,FINISH FLOOR ELEVATION \ ,, SERVICE DOOR SLAB MUST BE 2a'ABOVE GRADE \\ BUILDING COVERAGE WATER/CONSERVATION 0 Sq.Ft. COVERED Sq.Ft LOT Sq.Ft. % aQTAL DEDUCTION% 3,626 Sq.Ft. 2.893 Sq.Ft. 7,112 Sq.Ft. 41.1% NET SCO AREA 4.111 Sq.Ft. RV/ISM B:REVISE SITE PLAN-FLIP HOUSE(5/22/17)(TJ/11EB) REASON Al REVISE STE PUN-ADD NEW HOME(2/28/17)(TJ/CBG) PREPARED FOR:RIVERSIDE HOMES CERTIFIED TO:RIVERSIDE HOMES M.. r"""'" . BARTRAM TRAIL SURVEYING, INC. -- ria SN;, LAND SURVEYORS - PLANNERS - LAND DEVELOPMENT CONSULTANTS n-°Sr�.mW., OW=An M 0111 WA. 'J,l 1501 COUNTY ROAD 315 SUITE NO. 108 (904 284-2224 %us-rem ISMGREEN COVE SPRINGS, FL 32043 FAX (904 284-2258 "M 61 CERTIFICATE OF AUTHORIZATION LB #8 1 Etted=1.1:4X10,411/..4•Z _1e= .ea.rnm.L.r COPYRIGHT © 2018 -Mop6 .. NOTATION: F.I.RM.FLOOD ZONE %(N/A) LLowe a =u 'I HEREBY CERTIFY,that this survey graphically represents The survey hereon was mode without benefit of abstract or W/ELEVATION: at-WOO a the results of a field survey mode under my responsible search of title,and therefore the undersigned and Bartram PANEL NO.: direction and complies with the latest Standards of Trail Surveying make no Certifications regarding informatim 120077 D406K 6/3/13 1Me-�' �.we we,womgeort eswc. Practice for Surveys os promulgated by the Florida State shown or not shown hereon pertaining to easements,claims �'ri.: W •� �"4 Board of Professional Surveyors and Mappers, Chapter of easements.Rights-of-way,setback lines,overlaps. G; r..,.= 1mr"w".mm MM. 5.1-17 F.A.C.: Pursuant to section 472.027,Florida Boundary Line disputes,agreements.reservations or other N/A n, statues,subject to dl notes and notations shown hereon. simior matters Well may appear in the obstruct.on scorch. ¢x m oLe �� - N/A N/A This survey is prepared and certified for the exclusive use of DATE' 3/5/16 1'=30• Illaj_ 5.;_-_ FIELD WORK COMPLETED MAP ORIGINALLY SIGNED the diem named hereon and the survey map and report of wwar ,,,� the copies thereof ore not valid without the signature and PROJECT NO.: REASON VO ������ N/A the original raised seal of o Florida licensed surveyor and 1349-16-004 f B RAYMOND PAUL SUTHERLAND. P.S.M. mapper. mmoo Mt o SHEET 1 OF 1 STATE OF FLORIDA LICENSE NUMBER LS 6477 DRAWN BY: ANO CHECKED BY: DBG OFFICE COPY • DO NOT WRITE BELOW- OFFICE USE ONLY Applica I e Coles: 2010 F I ' DAB L i N CID _Review Result (circle one):, • • Approved Disapproved Approved w/ Conditions Review Initials/Date: rild, 6 '/2•�7 Development Size • • Habitable Space 9-2/0 E. F, Non-Habitable 96Y s•r; Impervious area • Miscellaneous Information Occupancy Group 023 Type of Construction V 6 Number of Stories 2 Zoning District 4 6 416e- . 66 Max. Occupancy Load • :ire Sprinklers Required • {food Zone ) ;onditions/Comments: • OFFICE COPY Atlantic Beach Country Club lot 37 1775 Atlantic Beach Drive Atlantic Beach, FL 32233 Single Family Detached-Group R3 2014 Florida Building Code Cronk Duch Architecture 1936 San Marco Blvd. Jacksonville, FL 32207 . k A § �, ,- ) Uln ®)k ! /\ }\\ j ` % ) �} `\k ; « a _ E \ : # II ( ) 3] § k § t § -g r I\ il \ \ c f %! { w {/ / \ }_ u. ) 5 {7 / 0 oz 0- q ` j\ \ }{ - ill \\ \\ } \ _0 2 . iii \»ƒ U. -�/\ 31.2 § E i -kf 8. 174 2E _ _ :- _ § § ai Do !){ Ti \ j \f f � \k £ / ))f \ f ! 3I ! � J 4260 0 k -)!§ 12 _ — \ % /f2 § : \ 2 k)/k — _ . fait \ ; =2 = . _ !/(\' \ \ ) \ 02// ) 7 f \ / . ■k000 i - 5 5 i - \ ! »a4 ; 0 { zi _ __ -- 2 §%;} ; a2zzz/Mz2z J 2 Z §§§§§3;#/7 tJ ! t \(§ .. ,--g:;:;;3!¥# §k \ \[( § vo !77 |. ® ; Tr3;; ! , , § 2 007]0 § 3 43" ! 7 ` j a%2fl cc _ }) ! co! =R ! -$ , ; � / k -§ s ! — ! 2 ! —t!c! f ;!|m { !}2gl; G 2 <`(/� k© w® C E R\ � r | |! °� —! ° ` _ m! |m! ( \ \\/\/ \m C. \0466 §\ \\\((/\N\§\§\ \ \0046\§§%\/ OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RIVER2710-West Indies Builder Name: Riverside Homes Street: 1775 Atlantic Beach Drive Permit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach,FL, 4 3 Permit Number: Owner: Oliver Residence Jurisdiction: 261100 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3022.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 2722.90 ft2 b.Frame-Wood,Adjacent R=13.0 235.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 65.00 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (2155.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=22.0 1930.00 ft2 6. Conditioned floor area above grade(ft2) 2710 b.Knee Wall(Unvented) R=19.0 225.00 ft2 c. N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(447.5 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 542 a. U-Factor: Dbl,U=0.35 447.50 ft2 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 48.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 5.473 ft. a.Electric Heat Pump 48.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 0.220 14.Hot water systems a.Natural Gas Tankless Cap: 1 gallons 8. Floor Types (2710.0 sqft.) Insulation Area EF:0.860 a.Slab-On-Grade Edge Insulation R=0.0 1917.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 780.00 ft2 None c.other(see details) R= 13.00 ft2 15.Credits Pstat Glass/Floor Area: 0.165 Total Proposed Modified Loads: 66.63 PASS Total Baseline Loads: 79.03 I hereby certify that the plans and specifications covered by Review of the plans and '0 •CKESz47,....,: this calculation are in compliance with the Florida Energy specifications covered by this i ti c ,. O;••: Digitally: nee Dou Douglas calculation indicates compliance `•44,4 '' • s ''::-.4.:4.:••4 : Code. by e P co: ii ,.3:.: DN.cn--Do�gIasRStId(Ies,cU5.O WC with the Florida EnergyCode. :ti!un,,. '" '".•',:'''si,�1�0 Douglas R.Stickles MastersINAC,Inc PREPARED BY: Date:20'7.04.2413:25:13-aroa Before construction is completed ' al - ,^.,.•-- ,. ......1 4 DATE: s'tvI_t'1 this building will be inspected for ; t,:. V ;a e compliance with Section 553.908 *`.. p � a ;` Florida Statutes. tS I hereby certify that this building, as designed, is in compliance ••. �5. with the Florida Energ Code. COD WE • OWNER/AGENT C Unds �rs BUILDING OFFICIAL: !_' /� DATE: _ -- ll� 1 DATE: /L 61-9'0 1 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 4/19/2017 1:19 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 , FORM R405-2014 PROJECT Title: RIVER2710-West Indies Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 3049 Lot# 37 Owner: Oliver Residence Total Stories: 2 Block/SubDivision: Atlantic Bch CC #of Units: 1 Worst Case: No PlatBook: 4 Builder Name: Riverside Homes Rotate Angle: 45 Street: 1775 Atlantic Beach Dri Permit Office: City of Atlantic Beach Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block/ 2710 26307 SPACES Number Name Area Volume Kitchen Occupants Bedrooms !al ID Finished Cooled Heated 1 1st Floor 1917 19170 Yes 2 1 1 Yes Yes Yes 1 2 2nd Floor 793 7137 No 2 2 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge lnsulatio 1st Floor 202.6 ft 0 1917 ft2 ____ 0.8 0 0.2 2 Floor Over Other Space 2nd Floor ---- ____ 780 ft2 0 0.15 0 0.85 3 Raised Floor 2nd Floor ____ ____ 13 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2091 ft2 0 ft2 Medium 0.4 No 0.4 No 22 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1930 ft2 N N 4/19/2017 1:19 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 , FORM R405-2014 CEILING V _# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) 1st Floor 0 Blown 1137 ft2 0.11 Wood 2 Knee Wall(Unvented) 1st Floor 19 Batt 70 ft2 0.11 Wood 3 Under Attic(Unvented) 2nd Floor 0 Blown 793 ft2 0.11 Wood 4 Knee Wall(Unvented) 2nd Floor 19 Batt 155 ft2 0.11 Wood WALLS / Adjacent Space Cavity Width Height Sheathing Framing Solar Below V_#__.Omt To --Wall Type - R-Value FtInFt In Area- R-Value -Fraction--Absw_Grade% _ 1 N=>NE Exterior Frame-Wood 1st Floor 19 16 9 10 167.5 ft2 0.23 0.75 0 2 E=>SE Exterior Frame-Wood 1st Floor 19 9 6 10 95.0 ft2 0.23 0.75 0 3 N=>NE Exterior Frame-Wood 1st Floor 19 23 9 12 285.0 ft2 0.23 0.75 0 4 E=>SE Exterior Frame-Wood 1st Floor 19 16 6 12 198.0 ft2 0.23 0.75 0 5 N=>NE Exterior Frame-Wood 1st Floor 19 4 6 10 45.0 ft2 0.23 0.75 0 _ 6 E=>SE Exterior Frame-Wood 1st Floor 19 20 10 200.0 ft2 0.23 0.75 0 7 S=>SW Garage Frame-Wood 1st Floor 13 23 6 10 235.0 ft2 0.23 0.01 0 _ 8 E=>SE Garage Frame-Wood 1st Floor 19 6 6 10 65.0 ft2 0.23 0.01 0 _ 9 S=>SW Exterior Frame-Wood 1st Floor 19 5 10 50.0 ft2 0.23 0.75 0 10 E=>SE Exterior Frame-Wood 1st Floor 19 4 6 10 45.0 ft2 0.23 0.75 0 11 S=>SW Exterior Frame-Wood 1st Floor 19 16 6 10 165.0 ft2 0.23 0.75 0 12 W=>NW Exterior Frame-Wood 1st Floor 19 55 6 10 555.0 ft2 0.23 0.75 0 13 N=>NE Exterior Frame-Wood 2nd Floor 19 6 6 9 58.5 ft2 0.23 0.75 0 _14 E=>SE Exterior Frame-Wood 2nd Floor 19 1 3 9 11.3 ft2 0.23 0.75 0 _15 N=>NE Exterior Frame-Wood 2nd Floor 19 5 6 9 49.5 ft2 0.23 0.75 0 _16 N=>NE Exterior Frame-Wood 2nd Floor 19 12 9 8 102.0 ft2 0.23 0.75 0 _17 E=>SE Exterior Frame-Wood 2nd Floor 19 13 3 3 6 46.4 ft2 0.23 0.75 0 18 S=>SW Exterior Frame-Wood 2nd Floor 19 12 9 8 102.0 ft2 0.23 0.75 0 _19 E=>SE Exterior Frame-Wood 2nd Floor 19 8 6 9 76.5 ft2 0.23 0.75 0 20 S=>SW Exterior Frame-Wood 2nd Floor 19 5 6 8 44.0 ft2 0.23 0.75 0 21 E=>SE Exterior Frame-Wood 2nd Floor 19 1 9 8 14.0 ft2 0.23 0.75 0 _22 S=>SW Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 23 W=>NW Exterior Frame-Wood 2nd Floor 19 31 3 9 281.3 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>SW Insulated 1st Floor None .46 3 8 24 ft2 2 S=>SW Insulated 1st Floor None .46 2 8 8 21.3 ft2 4/19/2017 1:19 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 225 degrees). V # OmWall Overhang Separation Int Shade Screening 1 N=>NE 1 Vinyl Low-E Double Yes 0.35 0.22 54.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 2 N=>NE 3 Vinyl Low-E Double Yes 0.35 0.22 128.0 ft2 10 ft 10 in 1 ft 0 in Drapes/blinds None 3 N=>NE 3 Vinyl Low-E Double Yes 0.35 0.22 32.0 ft2 10 ft 10 in 1 ft 0 in Drapes/blinds None 4 E=>SE 4 Vinyl Low-E Double Yes 0.35 0.22 25.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 5 E=>SE 6 Vinyl Low-E Double Yes 0.35 0.22 16.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 6 S=>SW 11 Vinyl Low-E Double Yes 0.35 0.22 42.0 ft2 9 ft 3 in 1 ft 0 in Drapes/blinds None 7 W=>NW 12 Vinyl Low-E Double Yes 0.35 0.22 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 8 W=>NW 12 Vinyl Low-E Double Yes 0.35 0.22 9.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 9 W=>NW 12 Vinyl Low-E Double Yes 0.35 0.22 37.5 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 10 N=>NE 13 Vinyl Low-E Double Yes 0.35 0.22 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 11 E=>SE 17 Vinyl Low-E Double Yes 0.35 0.22 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 12 S=>SW 20 Vinyl Low-E Double Yes 0.35 0.22 9.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 13 S=>SW 22 Vinyl Low-E Double Yes 0.35 0.22 18.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 14 W=>NW 23 Vinyl Low-E Double Yes 0.350.22 25.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 15 W=>NW 23 Vinyl Low-E Double Yes0.35 0.22 7.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None GARAGE ✓ # Floor Area Ceiling Area - Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 549 ft2 384 ft2 64 ft 10 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000308 2192.3 120.35 226.34 .2924 5 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 48 kBlu/hr 1 sys#1 COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts - 1 Central Unit Split SEER: 14 48 kBtu/hr 1440 cfm 0.75 1 sys#1 HOT WATER SYSTEM ✓ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.86 1 gal 60 gal 120 deg None 4/19/2017 1:19 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / Supply---- Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 542 ft2 Attic 135.5 ft Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb [[ Mar PA; [ Ma [X]Jun [X]Jul [X]Au [X]Se Oct ( Nov ( Dec HeatinX)Jan X Feb lX Mar ' 'Apr [ Ma [ ]Jun [ ]Jul [ ]Au [ 1 Se ' Oct [Xi Nov [XI Dec VentingJan Feb X Mar X Apr [ May [ ]Jun [ ]Jul [ ]Aug [ ]SepX Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEN) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/19/2017 1:19 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 84 The lower the EnergyPerformance Index, the more efficient the home. 1775 Atlantic Beach Drive, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 2722.90 ft2 b.Frame-Wood,Adjacent R=13.0 235.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=19.0 65.00 ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=22.0 1930.00 ft2 1 6. Conditioned floor area(ft2) 3049 b.Knee Wall(Unvented) R=19.0 225.00 ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.35 447.50 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 542 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 48.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 48.0 HSPF:8.20 Area Weighted Average Overhang Depth: 5.473 ft. Area Weighted Average SHGC: 8. Floor Types 0.220 Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1917.00 ft2 a.Natural Gas EF:0.86 b.Floor Over Other Space R=0.0 780.00 ft2 c.other(see details) R= 13.00 ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building • kiE sT,q Construction through the above energysavingfeatures which will be installed (or exceeded) ' �: ..T�'•:: 9 - �_ in this home before final inspection. Otherwise, a new EPL Display Card will be completed 7•<u~ °,,-4.'n`• based on installed Code compliant features 1 r/ , ;' __• ;;;,e,;.:.O �/ :":.-...*.,',...,,-i 4 Builder Signature: Date: I t� \ : ; �� ,�a 4..� a Address of New Home: fl TVs A tq_whc, a.(,e ity/FL Zip: .,....'` � . ,c COD X33 *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/19/2017 1:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 1775 Atlantic Beach Drive Permit Number: Atlantic Beach,FL, MANDATORY REQUIREMENTS See individual code sections for full details. O 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. o R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. • R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 4/19/2017 1:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Yz inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 4/19/2017 1:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 4/19/2017 1:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RIVER2710-West Indies Builder Name: Riverside Homes Street: 1775 Atlantic Beach Drive Permit Office: City of Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Oliver Residence Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. f Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. (/PC Exposed earth in unvented crawl spaces shall be covered with a Class I " vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. ✓ Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air / barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/19/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 Manual S Compliance Report Job: RIVER2710 wrightsoft° Date: 04/20/17 Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 Project Information For: Riverside Homes 12276 San Jose Boulevard, Suite#120, Jacksonville, FL 32223 Cooling Equipment Design Conditions Outdoor design DB: 93.0°F Sensible gain: 35807 Btuh Entering coil DB: 77.6°F Outdoor design WB:77.0°F Latent gain: 7302 Btuh Entering coil WB: 63.8°F Indoor design DB: 75.0°F Total gain: 43110 Btuh Indoor RH: 50% Estimated airflow: 1533 cfm Manufacturer's Performance Data atActual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0480000A+FB4CNP048L Actual airflow: 1533 cfm Sensible capacity: 33180 Btuh 93% of load Latent capacity: 10240 Btuh 140% of load Total capacity: 43420 Btuh 101% of load SHR: 76% Heating Equipment Design Conditions Outdoor design DB: 32.0°F Heat loss: 42249 Btuh Entering coil DB: 68.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0480000A+FB4CNP048L Actual airflow: 1533 cfm Output capacity: 46000 Btuh 109% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance:-99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1533 cfm Output capacity: 10.6 kW 86% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2017-Apr-20 10:05:51 �� wrightsoft" Right-Suite®Universal 2017 17.0.08 RSU13256 Page 1 SCA...side Homes\ATLANTIC Beach CC\ABCC37(Oliver).rup Calc=MJ8 Front Door faces:SW Project SummaryJob: RIVER2710 eld- wrightsoft° Date: 04/20/17 Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 Pro'ect Information For: Riverside Homes 12276 San Jose Boulevard, Suite #120, Jacksonville, FL 32223 Notes: Lot 37,Atlantic Beach C. C. Oliver Residence Desi• n Information Weather: Jacksonville, Intl Airport, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 30975 Btuh Structure 22567 Btuh Ducts 11274 Btuh Ducts 13240 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 42249 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 35807 Btuh Method Detailed Latent Cooling Equipment Load Sizing Shielding 3 (partial) Stories 1 Structure 3850 Btuh Ducts 3452 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 2710 2710 Equipment latent load 7302 Btuh Volume (ft3) 25745 25745 Air changes/hour 0 0 Equipment total load 43110 Btuh Equiv.AVF (cfm) 0 0 Req. total capacity at 0.70 SHR 4.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade 14 SEER PURON HP Trade 14 SEER PURON HP Model CH14NB0480000A Cond CH14NB0480000A AHRI ref 7835757 Coil FB4CNP048L AHRI ref 7835757 Efficiency 8.2 HSPF Efficiency 11.7 EER, 14 SEER Heating input Sensible cooling 32200 Btuh Heating output 45500 Btuh @ 47°F Latent cooling 13800 Btuh Temperature rise 27 °F Total cooling 46000 Btuh Actual air flow 1533 cfm Actual air flow 1533 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 31 °F Backup: Input = 11 kW, Output = 36182 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wr. htsoft 2017-Apr-2010:05:51 9 Right-Suite®Universal 2017 17.0.08 RSU13256 Page 1 ACCA ...side Homes\ATLANTIC Beach CCIABCC37(Oliver).rup Calc=MJ8 Front Door faces:SW wrightsoftRight-J®Worksheet Job: RIVER2710 Entire House Date: 04/20/17 By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville, FL 32256 Phone:904-722-8995 Fax.904-722-8944 1 Room name Entire House Whole House 2 Exposed wall 324.6 ft 324.6 ft 3 Room height 9.5 ft 9.5 ft heat/cool 4 Room dimensions 2710.0 x 1.0 ft 5 Room area 2710.0 ft' 2710.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 '.91 12E-Osw 0.068 ne 2.58 1.46 708 479 1238 700 708 479 1238 700 ).EG 3A-2ov 0.350 ne 13.30 22.99 229 0 3046 5265 229 0 3046 5265 141 12E-Osw 0.068 se 2.58 1.46 686 630 1628 921 686 630 1628 921 IG 3A-2ov 0.350 se 13.30 20.42 56 36 745 1143 56 18 745 1143 11 I 12E-Osw 0.068 sw 2.58 1.46 493 400 1034 585 493 400 1034 585 3A-2ov 0.350 sw 13.30 20.42 69 44 918 1409 69 22 918 1409 D 11J0 0.600 sw 22.80 18.36 24 24 547 441 24 24 547 441 1.EG0.068 nw 2.58 1.46 836 742 1917 1085 836 742 1917 1085 I-G 3A-2ov 0.350 nw 13.30 22.99 94 0 1250 2161 94 0 1250 2161 P 12B-Osw 0.097 - 3.69 1.73 300 279 1028 482 300 279 1028 482 I D 11J0 0.600 w 22.80 18.36 21 21 479 386 21 21 479 386 P 16B-Oad 0.408 - 15.50 22.07 155 155 2403 3421 155 155 2403 3421 C 16X19-0ad 0.408 n 2.15 1.59 1930 1930 4153 3069 1930 1930 4153 3069 F 20P-19w 0.050 - 1.90 0.70 13 13 25 9 13 13 25 9 F 22A-tph 1.358 n 51.60 0.00 1917 209 10765 0 1917 209 10765 0 6 c)AED excursion 0 0 Envelope loss/gain 31175 21077 31175 21077 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 3 690 Appliances/other 1000 1000 Subtotal(lines 6 to 13) 31175 22767 31175 22767 Less external load 200 200 200 200 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30975 22567 30975 22567 15 Duct loads 36% 59% 11274 13240 36% 59% 11274 13240 Total room bad 42249 35807 42249 35807 Air required(cfm) 1533 1533 1533 1533 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wr- F1ltsotFt- 2017-Apr-2010:05:51 _, A 9 Right-Suitei Universal 2017 17.0.08 RSU13256 Page 1 ..side Homes\ATLANTIC Beach CCVABCC37(Oliver).rup Calc=MJ8 Front Door faces:SW e BuildingAnalysis Job: RIVER2710 4 wrightsoft° y Date: 04/20/17 Entire House By: DRS A/C Masters HVAC, Inc. 445 Tresca Road,Suite#204,Jacksonville,FL 32256 Phone:904-722-8995 Fax 904-722-8944 Pro'ect Information For: Riverside Homes 12276 San Jose Boulevard, Suite#120, Jacksonville, FL 32223 Design Conditions Location: Indoor: Heating Cooling Jacksonville, Intl Airport, FL, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 38 18 Latitude: 31°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 11.5 50.0 Dry bulb (°F) 32 93 Infiltration: Daily range (°F) - 18 ( M ) Method Detailed Wet bulb (°F) - 77 Shielding 3 (partial) Wind speed (mph) 15.0 7.5 Stories 1 Heatin • Component Btuh/ft2 Btuh % of load Walls 3.4 9248 21.8 ,N,., Glazing 13.3 5958 14.0 c. Doors 22.8 1026 2.4 Ceilings 2.2 4153 9.8 Floors 5.6 10789 25.4 Infiltration 0 0 0 Ducts 11274 26.6 "°`"° Piping 0 0 Humidification 0 0 �«• Ventilation 0 0 ,. rb"` Adjustments -200 Total • 42249 100.0 Coolin • Component Btuh/ft2 Btuh % of load Walls 2.7 7194 20.0 ,aft em.!Gan Glazing 22.3 9979 27.7 Doors 18.4 826 2.3 Ceilings 1.6 3069 8.5 Floors 0.0 9 0.0 Infiltration 0 0 0 Ducts 13240 36.8 Ventilation 0 0 Internal gains 1690 4.7 Blower 0 0 °'az"° Adjustments -200 Total 35807 100.0 0 Latent Cooling Load = 7302 Btuh Overall U-value = 0.213 Btuh/ft2-°F Data entries checked. ,L wrl soft" 2017-Apr-20 10: 1 � ht 9 Right-Suited Universal 2017 17.0.08 RSU13256 Page 1 AI.�.P� ...side Homes\ATLANTIC Beach CC\ABCC37(Oliver).rup Calc=MJ8 Front Door faces:SW , ( 5' r 1 i I cum k �, rl t a 1.. wg E °W PI 8 2 5, 14P J x t+ § flf Nv. • E : $ sf# iii # ° J11 c w~e� �` '� a a a a Us # 01 el 1 ... R1 1 ,. 8 a h`. A — .2 il .14 d i tr 4"03111ZiNgq3 = :1 6 ) is tly * r _..- _-.....— gar - - ' 2 aWi 0 fl I g+l? 9 s 't !MX.- 61-• : ' 1-,-477 lilt." tg sA@ s 12 up it tl II K i'!I rm.1 go.. ' it V a #I` tea, r :b,• I u O E�. 2 ! c F ' l� • ' 7 1 11 A lid .. a n �.I k Z o w LdpO .iia_- a� S iii 2 J _ - " . I ��:I X17 -1-- -- ,t $1, 'W?'' Icill I- 11) J u 11=1 NMI ,...m. -- mili k A ,_ t vi TI !+ i©•ic 7 a—I , Io f it. , licn 1 N .a 1 d -1..z. '� " µ9�� N g s. � +a uJ z Hf N , i '.. li PrS /A T h gil %; 0 < r �i - 1 Ig 1 .s �\--=__ 4t...,„.....jam— '' a � •, Y i +!!l ir illir-T?" f , ....1 „..,..,Y ,h 1.1 _sill .E3 rAll _I : 0. 11 X al Nkl/41 l :� $ VII a r il,ri t O . _ e t[; ‹•% tit M _ ��IGti�I11T11 VII N 1DI 1 ���1 ,r, i tf t • -1 , { -11 124. Ylit - ; e AA fKl,. .. .rel .. KL-• °e a. a< e. 1795' ke‘,,iiciled% V-IN-006 Dov' i.U1 u ba Y 1/0Zae Alva �. 7rk 70f3 = 13/ 1/474WC /6-C ; irezy9bi 3iz�-x yylt 7 413.fru v yz : z rJ ; 41142/ fild AIWA .v. p.2. x z fa /7o 7 ° -1,77 4)44/0 , J4/_ 116 ;eeeiga7 .?/cXzo ° VO . R.O.W. Permit Attachment of for R.O.W. Permit# issued, , 200_ Atlantic Beach, FL 32233 Owner's Name: 'R,-% qt/i5\CAL kkanie S Property Address: \--15 FVAAa tet;,c_. j j Cin tr Ve- J 10..in c,''C 3 223 3 Subdivision: Mi4x1,11UI COK" G td.A Lot#/Block#: 1,04- 31 R.E. #: O5 - t '-4W REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT, issued on this 0 day of , 2041, by Atlantic Beach, Florida, a municipal corporation organized and existing uu d the 1 s of the State of Florida, hereinafter referred to as "CITY" and RWQrStc a “00-142,5 of Atlantic Beach, Florida,hereinafter referred to as "USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above (copies attached). This work is generally described as: IBJQUA) .*rLkC.* oto Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30) days notice by CITY to the USER, said notice to USER shall be given by certified mail, return receipt requested, to the following address: Q O I aaltrJO is r e- 13tc , aki4e o, Jack vi Ile, Ft- 3..1.433 The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating,replacing, or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes,Land Development Code,and all other land use and code requirements of the CITY, including City Code Section 19-7 (h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 L The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall, at the discretion of the CITY, be requested to submit as-built drawings showing the change within thirty(30) days after the day of completion. This permit shall insure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. DATE P • ' ( NED this ID day of , 204Q By' � __--el _ , L � Pr, ndrie-r _ • • signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this I 0 day of , 2001 personally a peared before me, a Notary Public i and for said County and State, Y ►S , the property owner of 11-1SftHa.1v►.hc. BcaCh sr. , Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instrument; who acknowledged to me that he or she exe ted the same freely and voluntarily and for the uses and purposes therein mentioned. otaryPubli 'Tor County an ate .���Y........... LINDSEY M.BISHOP l� :r° "' ° Notary Public-State of Flori a CITY OF ATLANTIC BEACH,FLORIDA, a •1 ? Commission#r FF 946204 municipal corporation: %'� ted' My Comm.Expires Jan 19.2020 4;;;. o . Approved: • ;04014 , Public ors 'rector For Permits where city sidewalk is impacted, City Manager approval required: Jim Hanson, City Manager Page 2 of 2 CITY OF ATLANTIC BEACH �r jj1.i., 1 CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS 800 Seminole Road 904-247-5800 \-- Atlantic Beach,Florida 32233-5445 Fax 904-247-5845 PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION. Date l \ 1---A PERMIT# Job Address `--1"1S -c-t\cur k'c_- 12,c ' chch ISSUED BY THE CITY �,l Permitee: �IVQ,YICAQ 1--\oc S O N. ft.IINC• Telephone# C404• �-L7•-1055 Permittee Address: lap-1u soLAJOS2 13w6) 4 la(D) e ONVI 11Q.j FL 3Ja23 Requesting Permission to Construct: tQA.13 C. .t\ *rU,C*lON- M. Location: (Reference to Cross-Street) 1. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Yes ( ) No ( ) Date: Bell South Telephone Company Yes ( ) No ( ) Date: Ferrell Gas Yes ( ) No ( ) Date: Comcast Yes ( ) No ( ) Date: 2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach . Florida Deoartoent of Transportation Standards and be performed under the supervAon of ,e 1 I' (Contractor's Project Superintendent) located at 4-6Ve_rSi 2 Cf`f es Telephone#: '�O3•-1OS5 4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with 30 days. If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of P :lic Works shall be notified twenty-four (24) hours prior to starting work and again immediately up. o pletio . OWNER i ..Otk___ Signed: . .IDate:43I t O I✓1 Before m is 10 day of in the Countyof Duval, State Of Florida,has personally appeared 1n IA.)O 'O( .- Notary Public at Large,State of Florida,County of Duval. i 7 ` / A My commission expires: Personally Kn.wn. , ' ` / 11 k Produced Identification: b`'"Y"6 LINDSEY M.BISHOP f. d`°�? Notary Public-State of Florida Commission#FF 946204 ' `' My Comm. Expires Jan 19,2020 0 - f International Fireproof Technology, Inc. / �-tv✓Yk(X' Paint To Protect TMbo- I may\ 4) 17528 Von Karman Ave.Irvine,CA 92614 949-975-8588 .„„,.... OFFICE COPY DC 315 applied over Spray Polyurethane Foam (SPF), If a coating has not passed a full scale test on a manufacturer's foam it _ is an Alternative Barrier System in "Section 2603.9 cannot be used on that foam;there are no exceptions in the IBC Code! Spedal Approval" as a thermal barrier. To be approved Building Code Fire Performance Requirements for SPF: as an Alternative Barrier System, DC 315 is applied over The International Building Code (IBC) mandates that SPF be separated a manufacturer's SPF and tested to the criteria of an from the interior of the building by a 15 minute thermal barrier, or other t NFPA 286, UL 1715, UL 1040, or FM 4880 for duration approved covering. DC 315 passed certified NFPA 286 and UL 1715 test of 15 minutes by an accredited fire testing facility. over a variety of open and closed cell spray applied urethane foams that Products that pass an ignition barrier tested under AC were conducted by ISA certified testing facilities. All tests performed 377 Appendix X are not appropriate alternative thermal barriers comply with the requirements of 2006 IBC Section 803.2.1 & 2009 IBC and cannot be used. Depending on your particular application, Section 803.1.2,and Section 2603.9;2012 IBC Section 803.1.2 and Section either ignition or thermal barriers are required by the International 2603.10 under "Special Approvals for Thermal Barriers over Foam Building Code (IBC). Plastics". DC315 is WHI marked and certified via 3'd party inspection for Properties Value quality assurance and consistency. Finish Flat Alternative 15 min Thermal Barrier Assemblies(e.g.Exposed SPF or SPF with a Thermal Barrier Protective Covering) Color Ice Grey The assembly must remain in place for 15 minutes during specified large- V.O.C. 47g/L scale fire tests,such as NFPA 286,UL 1715,UL 1040,or FM 4880. Solids By Volume 67% Alternative Ignition Barrier Assemblies DC 315 meets the requirements for ignition barrier per AC 377,Appendix X Specific Gravity 1.30+/-0.05 g/cc Application Equipment Drying Time @77°F & 50% R.H.—To touch 1—2 hours, to DC 315 can be applied by brush,roller or airless sprayer. recoat if required 2 to 4 hours For maximum yield and coverage spray application is recommended. Flash Point None Sprayers: Reducing or Cleaning Water Pump: (Graco)UltraMax 695 or equivalent PSI: 3000 Shelf Life 1 year from date of manufacture in unopened containers and stored at 1 0°C to 27°C(50°F to GPM: 1.00 80°F) Tip: 517-521 or equivalent. 5 Gal.Container Weight 58 lbs. Filter: 30 mesh, removal of filter is recommend from gun and machine Advantages of Using DC315 SPF Hose: 3/8"diameter airless spray line for the first 100'from pump and'"x 3'whip ■ DC 315 is the only 3`d party inspected fire protective coating for SPF Pump: (Graco)TexSpray Mark 5 or equivalent ■ Marked and Listed by Warnock Heresy Intertek W/N 20947 PSI: 3300 • Single coat coverage reducing labor and material costs equaling GPM: 1.35 higher profits Tip: 517-523 or equivalent. ■ Industry leading spread rate • Passed CAL 1350-safe for use in schools and high occupancy Filter: 30 mesh, removal of filter is recommend from gun and buildings machine • Passed strict EPA—V.O.C.and AQMD air emission requirements(for Hose: 3/8"diameter airless spray line for the first 100'from pump all 50 states) and A"x 3'whip • Approved for Incidental Food Contact complies with NSF/ANS1-51 requirements of USDA Pump: (Graco)GMAX 7900 or equivalent • Easily applied with a sprayer,roller,or brush with no complicated PSI: 3300 mixing GPM: 2.2 • 1 year shelf life Tip: 517-529 or equivalent. • Fast and easy clean-up,with no waste and fast turnaround time Filter: 30 mesh, removal of filter is recommend from gun and • Compatible with any paintable construction material machine • Meets Life Safety Code 101 Hose: 3/8"diameter airless spray line for the first 100'300' from • Meets LEED's point requirements pump and'''A"x 3'whip • No formaldehyde Pump: (Graco)GH 833 or equivalent DC 315 is the most tested and approved product in the world for use as PSI: 4000 an,"Alternative Thermal Barrier Coating System"over Spray GPM: 4.0 Polyurethane Foam(SPF). Tip: 517-529 or equivalent. Filter: 30 mesh, removal of filter is recommend from gun and Visit us at our website www.painttoprotect.com to obtain a current matrix machine of all the manufacturer's foams DC 315 has been tested and approved as Thermal or Ignition barriers in compliance with current IBC codes. Hose: 3/8"diameter airless spray line for the first 100'-300' from pump and IA"x 3'whip s .. Prior to Applying DC 315 to Ensure Proper Adhesion:Surfaces must General Safety,Toxicity,Health Data be clean,dry and free of all foreign matter.Adhesion of a coating to SPF Material Safety Data Sheets are available on this coating material. Any requires the foam surface to have a slight profile or texture similar to an > individual who may come in contact with these products should read and orange peel. Smooth or glossy foam surfaces must be flash coated with a 0, understand the M.S.D.S. In case of emergency contact CHEMTREC light 3-4 mils Wet Film Thickness(WFT)of DC 315 and allowed to dry 0 EMERGENCY NUMBER at 800-424-9300. before applying the full application. Flash coating is a quick burst of a primer or DC 315,via airless sprayer over an area needing treatment. We WARNING:Do not allow product to freeze.Store above 10°C(50°F)at all also recommend flash coating around all pipes and air ducts. W times. U Product Application j WARNING: Avoid eye contact with the liquid or spray mist. Applicators In order to validate warranty and confirm the installation complies with `a should wear protective clothes, gloves and use protective cream on face, IFTI's best practices, installer must obtain all current installation o hands and other exposed areas. documents and complete a daily work record for each and every job and for each sequential day a project is underway. Daily work records must EYE PROTECTION: be sent to IFTI within 10 days of project completion. Installation Safety glasses,goggles,or a face shield are recommended. documents include Application Guide,Ventilation Guide and Daily Work SKIN PROTECTION: Report. These documents can be downloaded at Chemical resistant gloves are recommended, cover as much of the www.painttoprotect.com or by calling IFTI at 949.975.8588 exposed skin area as possible with appropriate clothing. Material Preparation RESPIRATORY PROTECTION is MANDATORY! DC315 must be thoroughly mixed prior to application.Failure to do so will Respiratory protective equipment,impervious foot wear and protective compromise the materials performance and may create issues with clothing are required at all times during spray application. equipment used for the application of the product. Mechanical stirring with a high speed drill and a paddle appropriate for the container size is INGESTION:Do not take internally. recommended. Material should be stirred from the bottom up making sure the bottom and sides are scraped with a paint stick during the mixing Consider the application and environmental concentrations in deciding if process to ensure all materials are completely mixed prior to the additional protective measures are necessary. application. Material should be mixed to a creamy consistency with no lumps. Thinning is not usually needed, but if the material has been Limited Warranty exposed to prolonged periods of high temperatures during storage, This product will perform as tested if applied and maintained according to evaporation of the water based material may have taken place.Typically our directions, instructions and techniques. If this product is found to be the liquid level should be about 3 inches from the top of the 5 gallon pail. defective upon inspection by its representative, the seller will, at its If the level of material is lower,water may be added during the mixing to option,either furnish an equivalent amount of new product or refund the address this issue. purchase price to the original purchaser of this product. Seller will not be liable for any representations made by any retail seller or applicator of the Temperature and Humidity product. THIS WARRANTY EXCLUDES (1) LABOR OR COST OF LABOR FOR Ensure temperature and humidity are within specified limits for THE APPLICATION OR REMOVAL OF THIS PRODUCT OR ANY OTHER application. Failure to monitor and compensate for increased humidity PRODUCT,THE REPAIR OR REPLACEMENT OF ANY SUBSTRATE TO WHICH may lead to blistering and/or delamination and will void warranty.Obtain THE PRODUCT IS APPLIED OR THE APPLICATION OF REPLACEMENT a ventilation guide prior to commencing installation. Ideal conditions are PRODUCT, (2) ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. OTHER 16°C-32°C(62°F to 90°F)and a maximum of 65%Relative Humidity. LIMITATIONS APPLY.For the complete terms of the limited warranty,go to www.painttoprotect.com. Some states/provinces do not allow the Ventilation exclusion or limitation of incidental or consequential damages, so the When spraying in enclosed spaces,regardless of size,adequate ventilation above limitations may not apply to you.To make a warranty claim, write is required to remove excess moisture from the application area.The use to Technical Service, International Fireproof Technology, Inc., 17528 Von of fans may be required in some cases to ensure a minimum of 0.3 air Karman Avenue, Irvine, CA 92614 or email Customer Service at changes per hour. Prior to starting a job please be sure to download a ptp@painttoprotect.com complete current ventilation guide at www.painttoprotect.com Rev:11/16/2014 12:43 PM Current application documents must be on the job site at all times product is being applied.This includes application guide,ventilation guide and daily work report.Documents can be downloaded at http://www.painttoprotect.com or call IFTI at 949.975.8588 EZS ICC EVALUATION � SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report COPY ESR-3375 OFFICE COP I Reissued August 2014 This report is subject to renewal August 2016. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE pcf. The insulation's liquid components are supplied in PROTECTION nominally 55-gallon drums, labeled as "A" component or Section:07 21 00—Thermal Insulation "B" component. The insulation components have a shelf life of six months when stored in unopened containers at REPORT HOLDER: temperatures between 70°F(21°C)and 90°F(32°C). SES FOAM 3.2 Surface-burning Characteristics: 4008 LOUETTA ROAD,#538 At a maximum thickness of 4 inches (102 mm) and a SPRING,TEXAS 77388-4405 nominal density of 0.5 pcf, the insulation has a flame- (713)239-0252 spread index of 25 or less and a smoke-developed index of www.sesfoam.com 450 or less when tested in accordance with ASTM E84. Thicknesses of up to 111/2 inches (292 mm) for wall EVALUATION SUBJECT: cavities and ceiling cavities are recognized based on room corner fire testing in accordance with NFPA 286, when SES FOAM 0.5 lb SPRAY: SPRAY-APPLIED the insulation is covered with a minimum 1/2-inch-thick POLYURETHANE FOAM PLASTIC INSULATION (12.7 mm) gypsum board installed in accordance with the applicable code. 1.0 EVALUATION SCOPE 3.3 Thermal Resistance(R-values): Compliance with the following codes: The insulation has thermal resistance(R-values)at a mean • 2012 and 2009 International Building Code®(IBC) temperature of 75°F(24°C)as shown in Table 1. • 2012 and 2009 International Residential Code®(IRC) 3.4 Air Permeability: • 2012 and 2009 International Energy Conservation The insulation, at a minimum thickness of 3 inches Code®(IECC) (76 mm), is considered air-impermeable in accordance • Other Codes(see Section 8.0) with IRC Section R202, based on testing in accordance with ASTM E283. Properties evaluated: 4.0 INSTALLATION • Surface-burning characteristics 4.1 General: • Physical properties SES Foam 0.5 lb spray insulation must be installed in • Thermal resistance(R-values) accordance with the manufacturer's published installation • Attic and crawl space installation instructions and this report. A copy of the manufacturer's • Air permeability published installation instructions must be available at all times on the jobsite during installation. 2.0 USES 4.2 Application: SES Foam 0.5 lb spray polyurethane foam plastic The insulation is spray-applied at the jobsite using a insulation is used as a nonstructural thermal insulating volumetric positive displacement pump as identified in the material in buildings of Type V-B(IBC)construction, and in SES Foam 0.5 lb spray application manual. The insulation dwellings built under the IRC. The insulation is for use in components must be stored at temperatures between wall cavities and floor/ceiling assemblies, and in attics and 70°F (21°C) and 90°F (32°C) for several days before crawl spaces when installed as described in Section 4.4. application. The insulation must not be used in areas Under the IRC, the insulation may be used as air- that have maximum in-service temperatures greater than impermeable insulation when installed as described in 180°F (82°C). The insulation must not be used in Section 3.4. electrical outlet or junction boxes or in contact with water 3.0 DESCRIPTION (e.g., rain, condensation, ice, snow) or soil. The substrate 3.1 General: must be free of moisture, frost or ice, loose scales, rust, oil, grease or other surface contaminants. The insulation can SES Foam 0.5 lb spray foam insulation is a two- be installed in one pass to the maximum thickness. The component, open cell, one-to-one-by-volume spray-applied spray-applied foam insulation must be protected from polyurethane foam system with a nominal density of 0.5 weather during and after installation. li ICC-ES Evaluation Reports are not to he construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed a'_rCt as an endorsement of the subject of the report or a recommendation for its use.'There is no warranty by ICC Evaluation Service.LLC.express or implied,as e-l11A�S� to any finding or other matter in this report,or as to any product covered by the report. ta`xmwie Copyright®2014 Page 1 of 3 ESR-3375 I Most Widely Accepted and Trusted Page 2 of 3 4.3 Thermal Barrier: 5.0 CONDITIONS OF USE SES Foam 0.5 lb spray insulation must be separated from The SES Foam 0.5 lb spray polyurethane foam plastic the interior of the building by an approved thermal barrier insulation described in this report complies with, or is a of 1/2-inch-thick (12.7 mm) gypsum wallboard or an suitable alternative to what is specified in, those codes equivalent 15-minute thermal barrier complying with, and listed in Section 1.0 of this report, subject to the following installed in accordance with, IBC Section 2603.4 or IRC conditions: Section R316.4, as applicable. Within an attic or crawl 5.1 The insulation must be installed in accordance with space, installation must be in accordance with Section 4.4. the manufacturer's published installation instructions, 4.4 Attics and Crawl Spaces: this evaluation report and the applicable code. If there are any conflicts between the manufacturer's 4.4.1 Application with a Prescriptive Ignition Barrier: published installation instructions and this report, this When SES Foam 0.5 lb spray is installed within attics and report governs. crawl spaces, where entry is made only for service of 5.2 The insulation must be separated from the interior of the utilities, an ignition barrier must be installed in accordance building by an approved 15-minute thermal barrier, as with IBC Section 2603.4.1.6 or IRC Section R316.5.3 or described in Section 4.3. Installation in an attic or R316.5.4, as applicable. The ignition barrier must be crawl space must be as described in Section 4.4. consistent with the requirements for the type of construction required by the applicable code, and must be 5.3 The insulation must not exceed the thicknesses noted installed in a manner so that the foam plastic insulation is in Sections 3.2 and 4.4. not exposed. SES Foam 0.5 lb spray insulation at a 5.4 The insulation must be protected from exposure to the minimum thickness of 3 inches(76 mm)may be installed in weather during and after application. unvented attics in accordance with 2012 IRC Section R806.5(2009 IRC Section R806.4), as applicable. 5.5 The insulation must be applied by contractors certified by SES Foam. 4.4.2 Application without a Prescriptive Ignition Barrier: Where the spray-applied insulation is installed in 5.6 Use of the insulation in areas where the probability of accordance with this section (Section 4.4.2) or Section termite infestation is "very heavy" must be in 4.4.3,the following conditions apply: accordance with 2012 IBC Section 2603.9 (2009 IBC Section 2603.8)or IRC Section R318.4, as applicable. a) Entry to the attic or crawl space is to service utilities, 5.7 Jobsite certification and labeling of the insulation must and no storage is permitted. comply with IRC Sections N1101.4 and N1101.4.1 b) There are no interconnected attic or crawl space and IECC Sections R303.1.1 and 303.1.1.1, as areas. applicable. c) Air in the attic or crawl space is not circulated to other 5.8 SES Foam 0.5 lb spray polyurethane foam plastic parts of the building. insulation is produced in St. Louis, Missouri, under a quality control program with inspections by ICC-ES. d) Attic ventilation is provided when required by IBC 6.0 EVIDENCE SUBMITTED Section 1203.2 or IRC Section R806, except when air-impermeable insulation is permitted in unvented 6.1 Data in accordance with the ICC-ES Acceptance attics in accordance with 2012 IRC Section R806.5 or Criteria for Spray-applied Foam Plastic Insulation 2009 IRC Section R806.4. Under-floor (crawl space) (AC377), dated June 2012, including reports of tests ventilation is provided when required by IBC Section in accordance with Appendix X of AC377. 1203.3 or IRC Section R408.1, as applicable. 6.2 Report of room corner fire testing in accordance with e) Combustion air is provided in accordance with NFPA 286. International Mechanical Code®Section 701. 6.3 Report of air permeance testing in accordance with In attics, the insulation may be spray-applied to the ASTM E283. underside of roof sheathing or roof rafters, and/or vertical 7.0 IDENTIFICATION surfaces, and in crawl spaces the insulation may be spray Components of the SES Foam 0.5 lb spray polyurethane applied to the underside of floors and/or vertical surfaces as described in this section. The thickness of the foam foam plastic insulation are identified with the plastic applied to the underside of the top of the space manufacturer's name (SES Foam) and address; the date must not exceed 12 inches(305 mm). The thickness of the of manufacture or the lot number; the product trade name foam plastic applied to vertical surfaces must not exceed (SES Foam 0.5 Ib); the mixing instructions; the density;the 111/2 inches (292 mm). The foam plastic may be installed flame spread and smoke developed indices, and the without a covering or coating. The insulation may be evaluation report number(ESR 3375). installed in unvented attics in accordance with 2012 IRC 8.0 OTHER CODES Section R806.5 (2009 IRC Section R806.4). The ignition In addition to the codes referenced in Section 1.0, the barrier in accordance with IBC Section 2603.4.1.6 or IRC products in the report were evaluated for compliance with Section R316.5.3 may be omitted. the requirements of the following codes: 4.4.3 Use on Attic Floors: SES Foam 0.5 lb spray ■ 2006 International Building Code®(2006 IBC) insulation mays be installed exposed at a maximum 2006 International Residential Code®(2006 IBC) thickness of 111/2 inches (292 mm) between joists in attic • floors. The ignition barrier in accordance with IBC Section ■ 2006 and 2003 International Energy Conservation 2603.4.1.6 or IRC Section R316.5.3 may be omitted. The Code®(2006 IECC) insulation must be separated from the interior of the building by an approved thermal barrier. ESR-3375 I Most Widely Accepted and Trusted Page 3 of 3 The products comply with the above-mentioned codes as provided in accordance with Sections 701 and 703 of described in Sections 2.0 through 7.0 of this report, with the 2006 IECC. revisions as noted below: • Protection against Termites: See Section 5.6, except • Application with a Prescriptive Thermal Barrier: See use of the insulation in areas where the probability of Section 4.3, except the approved thermal barrier must termite infestation if"very heavy"must be in accordance be installed in accordance with Section R314.4 of the with Section R320.5 of the 2006 IRC. 2006 IRC. • Jobsite Certification and Labeling: See Section 5.7, • Application with a Prescriptive Ignition Barrier: See except jobsite certification and labeling must comply Section 4.4.1, except an ignition barrier must be with Sections 102.1.1 and 102.1.1.1, as applicable, of installed in accordance with Section R314.5.3 or the 2006 IECC. R314.5.4 of the 2006 IRC. • Application without a Prescriptive Ignition Barrier: See Section 4.4.2, except that combustion air is TABLE 1—THERMAL RESISTANCE(R-VALUES12) THICKNESS(inches) R-VALUE(°F•ft2•h/Btu) 1 4.0 2 7.6 3 11 3.5 13 4 15 5 19 6 22 7 26 8 30 9 33 10 37 11 41 12 44 For SI: 1 inch=25.4 mm,1°F•ft2•h/Btu=0.176 110K•m2/W. 1R-values are calculated based on tested K values at 1-and 3.5-inch thicknesses. 2R-values greater than 10 are rounded to the nearest whole number. �S ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES VAR Environmental Report VAR-1030* Reissued July 2013 This report is subject to renewal September 1, 2015. www.icc-es.orq/ep 1800-423-6587 I (562)699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE high-pressure, plural component SPF application PROTECTION equipment. The bio-based content is as set forth in Table 1 Section:07 21 00—Thermal Insulation of this report. REPORT HOLDER: 4.0 CONDITIONS 4.1 Code Compliance: SES FOAM See ICC-ES report ESR-3375 for compliance of the SES 4008 LOUETTA ROAD,#538 Foam 0.5 lb Foam S Polyurethane Foam Plastic Insulation SPRING,TEXAS 77388-4405 with code requirements. (713)239-0252 www.sesfoam.com 4.2 Green Codes, Standards and Rating Systems Eligibility: EVALUATION SUBJECT: The information presented in Tables 2 through 5 of this report provides a matrix of areas of evaluation and SES FOAM 0.5 lb SPRAY POLYURETHANE FOAM corresponding limitations and/or additional project-specific PLASTIC INSULATION requirements, and offers benefits to individuals who are 1.0 EVALUATION SCOPE assessing eligibility for compliance. The final interpretation of the specific requirements of the Compliance with the following environmental criteria: code rests with the Authority Having Jurisdiction. ICC-ES Environmental Criteria for Determination of Compliance for items noted as "Verified Attribute" is Bio-based Material Content(EC102),dated March 1, 2012. subject to any conditions noted in the tables. Decisions on Compliance eligibility with the applicable sections of compliance for those items noted as "Eligible for Points" in the following codes and standards: Tables 2 through 5 rests with the user of this report, and • 2012 International Green Construction CodeTM (IgCC) those items are subject to the conditions noted. The user is advised of the project-specific provisions that may be (see Table 2 for details) contingent upon meeting specific conditions, and the • ASHRAE Standard 189.1 – 2009 (see Table 3 for verification of those conditions is outside the scope of this details) report. • National Green Building Standard (ICC 700-2008) (see Due to the variability of costs and volume, the bio-based Table 4 for details) content percentage listed in this report is based upon weight (mass). The use of cost or volume as the method • ANSI/GBI 01-2010, Green Building Assessment for calculation is outside the scope of this report. Protocol for Commercial Buildings (see Table 5 for details) 5.0 BASIS OF EVALUATION 2.0 USES The information in this report, including the "Verified Attributes," is based upon submission of documentation SES Foam 0.5 lb Foam S Polyurethane Foam Plastic demonstrating compliance with the requirements set forth Insulation is used as nonstructural thermal insulating in ICC-ES EC102. (Evaluation applies to IgCC Section material in wall cavities, floor/ceiling assemblies, or in 505.2.4, item 3; ASHRAE 189.1 Section 9.4.1.3; ICC 700 attics and crawl spaces. See ICC-ES report ESR-3375 for Section 606.1; ANSI/GBI-01 Section 10.1.2.2.) more information on uses and applications. 6.0 IDENTIFICATION 3.0 DESCRIPTION Containers of SES Foam 0.5 lb Foam S Polyurethane SES Foam 0.5 lb spray-applied polyurethane foam plastic Foam Plastic Insulation are identified by a label bearing the insulation is a two-component, open-cell, water-blown, SES Foam name and address, product name, spray-applied polyurethane foam (SPF) with a nominal manufacturing date, manufacturing location and the VAR density of 0.5 Ib/ft3. The foam is sprayed in place using Environmental Report number(VAR-1030). *Corrected May 2014 1CC-ES Verification of Attributes Reports are issued under the ICC-ES VAR Environmental Program.These reports are not to be construed as representing aesthetics or any other ICC attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied.as to any finding or other matter in this report.oras to any product covered by the report. - • siwuxw Uuao� Copyright®2014 Page 1 of 2 VAR-1030 I Most Widely Accepted and Trusted Page 2 of 2 TABLE 1—BIO-BASED MATERIAL CONTENT SUMMARY PRODUCT NAME %MEAN BIO-BASED CONTENT METHOD OF DETERMINATION SES Foam 0.5 lb Spray Polyurethane Foam Plastic Insulation 17%(+/-3%)1 ASTM D6866 Note: 'Based on precision and bias cited in ASTM D6866. TABLES 2 THROUGH 5 Section Possible Number Section Intent Points Conditions Of Use To Qualify For Points Finding TABLE 2—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2012 INTERNATIONAL GREEN CONSTRUCTION CODE Bio-based materials shall be those materials that comply with one or more of the following: 505.2.4 Bio-based content N/A 3.The requirements of USDA 7CFR Part 2902. • Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 3—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2009 ASHRAE STANDARD 189.1 A minimum of 5%of building materials used,based on cost,shall be biobased products. Biobased products shall comply with the minimum biobased contents of the USDA's Designation of Biobased Items for Federal Procurement[7 CFR Part 29021,contain the 9.4.1.3 Biobased products N/A "USDA Certified Biobased Product"label,or be composed of solid wood,engineered • wood,bamboo,wool,cotton,cork,agricultural fibers,or other biobased materials with at least 50%biobased content. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 4—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2008 NATIONAL GREEN BUILDING STANDARD(ICC 700) The following biobased products are used: (h)products with the minimum biobased contents of the USDA 7 CFR Part 2902 606.1 Biobased products 3 (i)other biobased materials with a minimum of 50 percent biobased content(by weight 8 max or volume) Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 5—SUMMARY OF AREA OF ELIGIBILITY WITH THE ANSI/GBI–01 (2010)STANDARD Bio-based products accounted for 1%or more of the materials used in the building. Percentage=100 x A=B,where: • A=Total cost or weight of bio-based products B=Total cost or weight of all building products 10.1.2.2 Materials content– 1 Cost or weight must be used consistently • Assemblies 7 max For USDA-designated products,products meeting or exceeding USDA's bio-based content,criteria or qualifying as USDA"BioPreferred"were used. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. • =Verified attribute ICC EVALUATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-3375 Seal and Insulate with ENERGY STAR®Supplement Reissued August 2014 This report is subject to renewal August 2016. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section:07 21 00—Thermal Insulation REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD,#538 SPRING,TEXAS 77388-4405 (713)239-0252 www.sesfoam.com EVALUATION SUBJECT: SES FOAM 0.5 lb SPRAY: SPRAY-APPLIED POLYURETHANE FOAM PLASTIC INSULATION 1.0 EVALUATION SCOPE Conformance to the following: Seal and Insulate with ENERGY STAR® Program—Definitions and Testing Requirements for Residential Insulation, Version 1.0 Properties evaluated: • Thermal resistance • Surface-burning characteristics 2.0 PURPOSE OF THIS SUPPLEMENT This supplement is issued to certify that the insulation products described in Sections 2.0 through 8.0 of the master report ESR-3375 have been reviewed for compliance with the requirements of the Seal and Insulate with ENERGY STAR® Program, as set forth in the document Definitions and Testing Requirements for Residential Insulation, Version 1.0. The insulation product covered by this supplement is defined as"Spray or Pour Foam Insulation." The requirements for testing laboratory qualification and product sampling, as well as the specific material and test standards and editions used in this evaluation, are as set forth in the applicable documentation noted in Section 6.0 of the master evaluation report. 3.0 DEFINITIONS The following definitions are from Definitions and Testing Requirements for Residential Insulation, Version 1.0, and are applicable to the subject of this report. 3.1 General Definitions: Insulation: Any material mainly used to slow down heat flow. It may be mineral or organic, fibrous, cellular, or reflective (aluminum foil). It may be in rigid,semi-rigid,flexible, or loose-fill form. 3.2 Insulation Product Definitions: Spray or Pour Foam Insulation:A thermal insulating material that is sprayed or poured (as a gel or foamy liquid) into place, and expands or sets into a cellular foam and cures at the point of installation through a chemical reaction. Foamed materials include, but are not limited to polyurethane, polyisocyanurate, phenolic,and cementitious insulation. 3.3 Insulation Performance Definitions: R-value: The inverse of the time rate of heat flow through a body from one of its bounding surfaces to the other surface for a unit temperature difference between the two surfaces, under steady state conditions, per unit area. For the purposes of the Seal and Insulate with ENERGY STAR®program, Imperial units will only be accepted ((h•ft2•°F)/Btu]. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed _as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as ANSI to any finding or other matter in this report,oras to any product covered by the report. t;rialt Copyright®2014 Page 1 of 6 ESR-3375 I Most Widely Accepted and Trusted Page 2 of 6 Smoke-Development Index: The characteristic of a material to emit smoke when exposed to flame or fire compared to red oak and inorganic cement. Flame-Spread Index: The characteristic of a material to resist the spreading of flames when exposed to flame or fire compared to red oak and inorganic cement. 3.4 Thermal Resistance: The insulation has the thermal resistance R-values as noted in Table 1 of ESR-3375, based upon testing. 3.5 Installation: 3.5.1 General: The installation of the insulation must be in accordance with the requirements set forth in Sections 4.0 and 5.0(as applicable)of ESR-3375.The insulation is manufactured on-site by spray polyurethane foam applicators meeting the qualification requirements of SES Foam. The following information on personal protective equipment and ventilation requirements is reprinted from the SES Foam published installation instructions: "F. SAFETY 3. PERSONAL PROTECTIVE EQUIPMENT(PPE): a. Skin: Wear gloves, coveralls, apron and boots as necessary to prevent contact of liquid components or partially-cured SPF with skin.When handling liquid components,gloves should be made of nitrile, neoprene, butyl or PVC. b. Eyes: Protect eyes while handling liquid components or spraying with safety goggles or safety goggles and a face shield. During spray application,eye protection may be provided by a full-face or hood respirator. c. Respiration: Firms engaged in the application of SES Foam systems must have a written respiratory protection program for employees engaged in handling or applying SES Foam materials. Depending on the situation, respiratory protection may include dust masks, air-purifying respirators (APR), powered air-purifying respirators (PAPR), or supplied- air respirators(SAR). 4. VENTILATION: Provide ventilation and other engineering controls to exhaust vapors from work areas and to protect building occupants and other trades." 3.5.2 Occupancy Time after Installation: The re-entry or re-occupancy time shall be in accordance with the manufacturer's installation instructions,which state the following: "E. RE-ENTRY SES Foam 0.5 lb Spray reacts and cures within seconds of application. Re-entry times will vary depending on factors including ventilation. Typically, ventilation is continued for 24 hours following the conclusion of spray application and re-entry may occur at that time." 3.5.3 Figures:The figures shown represent general installations of the insulation in the following applications: above-grade wall, below-grade wall, vented and unvented crawl space, unvented cathedral ceiling, and vented and unvented attic. These figures are for illustration purposes and are not to be construed or used as construction documents. This supplement expires concurrently with the master report, reissued August 2014. ESR-3375 I Most Widely Accepted and Trusted Page 3 of 6 �..°°v"O ,'0-0: +pp 000000„Op°"DOUo°avO00"Q p0"O °oo°°0 0000°o0 0°0oo°00a0o0o 0°°00°°o°°0a 00°000°0oo°000° 0000°0000000000°00°000°000 o° o°° 00%000 °000000°„ 0°,soo°no° 0°0o°0a 0a°000 °°0a°a °00°°00 0°000° a°00oo °00°°00 0 fl° O°.-n0 cl° 4 -0 0 � °000°0. >00°oa°°o )0-00000 Interior Partition 4 )00000°oc o° oo° o 00000000 )0°000-0( ,00 Interior Finished Surface 0 0°000°0 (112-inch Sheetrock) �0 00,0000c a ;000ao0o, >0° O p°0a o, O00:00g,4O4°0SES Foam 0.5 lb Spray aahOOQoo Soo° 000 00° Exterior Sheathing Woo°0 _nOl�,n°°. SES FOAM 0.5 LB SPRAY ABOVE GRADE WALL INSULATION SES 05-1 071812 I 1 I ESR-3375 I Most Widely Accepted and Trusted Page 4 of 6 O.cc4" 000 / Masonry Block 0<> j ..;;I "7••••‘:.:;;V....1 4<1111110.,„„. o' Interior Finish Surface (1/2-inch Sheetrock) !�/o - 2"x 4"Studs �1�,' • SES Foam 0.5 lb Spray - ..!...y( -AP- f: . . . ! SES FOAM 0.5 LB SPRAY I BELOW GRADE WALL INSULATION I SES 05-2 I 071812 (Insulation on Interior Side of Wall) /j/i Baffle to provide � ' air space between /yam/� Thermal insulation and roof j� Barrier' deck. ///i�� (as required //////i�� by local code) 00000. 00000000000000000000,00000000000°0000000Q0000• �j :: :000oo0o00000000 Ilillil "Oo°o°o°o `'Oo°o°o°o �000 o°o SES Foam 0.5 lb Spray 10o°° °° °o 1 ° ° o ° oo°I o °0°0°0°0 oggg 0°00°00°0°°0 0°0°0°0° 00000000 �o°o°o° Vented Soffit 00000000 o°o°o°o° ° °°° No000 0000°°°° *Where attic entry is for the °0°00000 0000°°°° service of utilities only,thermal SES Foam 0.5 lb Spray o°0°0°0° 00°°0000 and igniton barrier on the attic °°0o ° side of the spray foam surface �V may be omitted. SES FOAM 0.5 LB SPRAY VENTED ATTIC:FLOOR/SOFFIT SES 05-3 071812 ESR-3375 I Most Widely Accepted and Trusted Page 5 of 6 oe;Z O° Subfloor 0000 SES Foam 0.5 lb Spray ►ii gggf .. °;° °°°°° " °° °°"°eo °° ; Header ....Nee—. � eiiiiiiiiii.'.: ,yOOOp;t;Sill r - - - l..•.'; A ag: Joist Floor Cross Section ►�i�i�i�i ►������•• Thermal Barrier* (as required Exterior Grade �iiiii q by / ������ local code) X\\ice\\�\\\%%%• • ►��������� 6"Min • p yr ►i�i�i�i�i Footer Vapor Barrier \/\/ .: 'Where crawispace entry is for the • ~. •: \\ \ \ / •,. ^.�\\ \\ \\ service of utilities only,thermal :..-:• % � and igniton barrier on the crawispace 4 side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY CRAWLSPACE:VENTED SES 05-4 071812 A iilliSubfloor 2::: 4.: ►i Header 'ggogogogo e° oggg°gg°°g°° rte'+ °g : ' °g. ' . - --N go Sill I -. Joist Oi•���4 gogog ►�������g,g,g Thermal Barrier' .•••-•.'ggggg (as required by Exterior Grade ������-��0008e local code) 40. /.\\///,��///.\ % %%os.o °O°° ••.•.•.. SES Foam 0.5 lb Spray Footer--..„........ Pi�i1 6"Min Vapor B-rrier .! \\// !i/_0' •'• / / // 'Where crawispace entry is for the service of utilities only,thermal and igniton barrier on the crawispace side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY CRAWLSPACE:UNVENTED SES 05-5 071812 ESR-3375 I Most Widely Accepted and Trusted Page 6 of 6 Note:In cold climates,embed metal connector plates in spray foam to prevent winter-time condensation. �}/�{(\ 000000;3;0; 00000\ 0000,• o.i o000 SES Foam 0.5 lb Spray oo...... �y ��O000\ 00000 ••00000 00 / '•°o\ 0 oRoof Sheathing /o00: i ` r0 • ...;ego?- ,;q0 Truss Top Cord/ ,• °0 °°' o0�0• Rafter 000ao • oo0oo nnnnnnnnnnnn I��- Thermal Barrier' (as required by local code) Note:Local building code may V require the use of a vapor retarder 'n cold climate zones. Ceiling/Thermal Barrier 'Where attic entry is for the as required by local building code. service of utilities only,thermal and igniton barrier on the attic side of the spray foam surface may be omitted. SES FOAM 0.5 LB SPRAY UNVENTED ATTIC/INSULATED ROOF DECK SES 05-6 071812 I °°SES Foam 0.5 lb Spray O 10 -to specified thickness. • O O O• •00000•' O4 Roof Sheathing • O O • •0000000• • . Thermal Barrier as Rafter •O 0 O 1" required by code. •O =:/ Note:The local building code of a ay requirerthe installation slim to a vapor barrier in cold climate ' zones. 1 SES FOAM 0.5 LB SPRAY CATHEDRAL CEILING SES 05-7 071912