743 SAILFISH DR - ENERGY SHEETS 1
f
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1802 Builder Name: X L Properties OFFICE COPY
Street: 743 Sailfish Drive Permit Office: City of Atlantic Beach r G
City,State,Zip: Jacksonville, FL, Permit Number:
Owner Jurisdiction: 261300
Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2221.3 sqft.) Insulation Area
a.Frame Wood,Exterior R=13.0 1761.30 ft2
2. Single family or multiple family Single-family
b.Frame-Wood,Adjacent R=13.0 364.00 ft2
3. Number of units,if multiple family 1 c. Frame-Wood,Exterior R=19.0 96.00 ft2
4. Number of Bedrooms 4 d. N/A R= ft2
10.Ceiling Types (1971.2 sqft) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1802.00 ft2
6. Conditioned floor area above grade(ft2) 1802 b.Knee Wall(Vented) R=19.0 169.20 ft2
c. N/A R= ft2
Conditioned floor area below grade(ft2) 0 11.Ducts R ft2
7. Windows(210.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 135
a. U-Factor: Dbl,U=0.35 v/ 210.27 ft2
SHGC: SHGC=0.29 kBtu/hr Efficiency U-Factor: N/A ft2 12.Cooling systems
a.Central Unit 34.8 SEER:15.00
SHGC:
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.385 ft.
Area Weighted Average SHGC: 0.290 14.Hot water systems
a. Electric Cap:55 gallons
8. Floor Types (1802.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1802.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 50.23 PASS
Glass/Floor Area: 0.117
Total Baseline Loads: 50.62
I hereby certify that the plans and specifications covered by Review of the plans and .>0O• �•�NE STA TF''••.,
this calculation are in compliance with the Florida Energy specifications covered by this 441.• v:;".h - •...O,po.
Code. calculation indicates compliance i „
/�G.�2 1/ / with the Florida Energy Code. ;.m"..... r',.,%
j�ra.2,14,. Before construction is completed • • Q
PREPARED BY: __ - --- inspected : oc=.
DATE: '1920" -��7 7� �� cc'''. this building will be for ; 0 ' , , ,) c
compliance with Section 553.908 ': .,. a"sI a .- /u
Florida Statutes. ' r ,
I hereby certify that this building .s d;line., is in compliance ,'VC "Jc,:'
with the Florida En- :• ••e� _ OD wE' ..••'
OWNER/AGENT: r. " ���%;`' BUILDING OFFICIAL:
DATE: - -AFFM/F-7 DATE: ___ -__ ' l• /7
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2).
REVISION
96 , /7 EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4
SIGNED
FORM'R405-2014
PROJECT
Title: 1802 Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1802 Lot#
Owner: Total Stories: 1 BlocklSubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: X L Properties Rotate Angle: 0 Street: 743 Sailfish Drive
Permit Office: City of Atlantic Beach Cross Ventilation: No County: Duval
Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Jacksonville,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Blodkl 1802 16218
li SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated
1 Main 1802 16218 Yes 5 4 1 Yes Yes Yes
FLOORS
V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 224.8 ft 0 1802 ft2 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1899 ft2 0 ft2 Medium 0.65 N 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1802 ft2 N N
CEILING
V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1802 ft2 0.1 Wood
2 Knee Wall(Vented) Main 19 Batt 169.2 ft2 0.11 Wood
iii
41
7/19/2017 11:01 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Space pe Cavity Width Height Sheathing Framing Solar Below
V# Omt To Wall Type e R-Value Et . In ----FL_.-In -----..-Area_ R-Value Fraction_ Ahsor Grades%_
_ 1 N Exterior Frame-Wood Main 13 57 11 8 0 463.0 ft2 0 0.25 0.6 0
2 N Exterior Frame-Wood Main 19 3 0 8 0 24.0 ft2 0 0.25 0.6 0
3 NE Exterior Frame-Wood Main 13 2 10 10 0 28.3 ft2 0 0.25 0.6 0
4 E Exterior Frame-Wood Main 13 53 11 8 0 431.0 ft2 0 0.25 0.6 0
5 S Exterior Frame-Wood Main 13 52 11 8 0 423.0 ft2 0 0.25 0.6 0
6 S Exterior Frame-Wood Main 19 6 0 8 0 48.0 ft2 0 0.25 0.6 0
_ 7 W Exterior Frame-Wood Main 13 52 0 8 0 416.0 ft2 0 0.25 0.6 0
8 W Exterior Frame-Wood Main 19 3 0 8 0 24.0 ft2 0 0.25 0.6 0
9 - Garage Frame-Wood Main 13 45 6 8 0 364.0 ft2 0 0.25 0.01 0
DOORS
V # Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S Insulated Main None .39 3 6 10 20.5 ft2
2 - Insulated Main None .39 2 10 6 10 19.4 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 n 1 Vinyl Low-E Double Yes 0.35 0.29 8.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None
2 n 1 Vinyl Low-E Double Yes 0.35 0.29 30.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None
3 n 1 Vinyl Low-E Double Yes 0.35 0.29 30.0 ft2 10 ft 0 in 2 ft 0 in Drapes/blinds None
4 ne 3 Vinyl Low-E Double Yes 0.35 0.29 19.3 ft2 9 ft 0 in 2 ft 0 in Drapes/blinds None
5 e 4 Vinyl Low-E Double Yes 0.35 0.29 8.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None
6 e 4 Vinyl Low-E Double Yes 0.35 0.29 30.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None
7 s 5 Vinyl Low-E Double Yes 0.35 0.29 30.0 ft2 6 ft 0 in 2 ft 0 in Drapes/blinds None
8 s 5 Vinyl Low-E Double Yes 0.35 0.29 16.0 ft2 6 ft 0 in 2 ft 0 in Drapes/blinds None
9 w 7 Vinyl Low-E Double Yes 0.35 0.29 9.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None
10 W 7 Vinyl Low-E Double Yes 0.35 0.29 30.0 ft2 1 ft 6 in 2 ft 0 in Drapes/blinds None
GARAGE
V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 22482 ft2 384 ft2 50 ft 9 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004 1892.1 103.87 195.35 .3082 7
7/19/2017 11:01 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 4
FORM,R405-2014
HEATING SYSTEM
✓ # System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:15 34.8 kBtu/hr cfm 0.7 1 sys#1
HOT WATER SYSTEM
✓ # System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 55 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
V —Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 135 ft2 Attic 35 ft2 Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling Jan Feb Mar Apr May Jr, ;Jul Aug Sep Oct Nov ' Dec
Heating X Jan xi Feb Mar Apr May JuJul Aug Sep Oct X'Nov )()Dec
Venting Jan Feb )( Mar X Apr May j�Jun ' Jul j�Aug Sep X Oct X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
7/19/2017 11:01 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
743 Sailfish Drive, Jacksonville, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
a.Frame-Wood,Exterior R=13.0 1761.30 ft2
2. Single family or multiple family Single-family b. Frame-Wood,Adjacent R=13.0 364.00 ft'
3. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 96.00 ft'
4. Number of Bedrooms 4
d. N/A R= ft'
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1802.00 ft2
6. Conditioned floor area(ft') 1802 b.Knee Wall(Vented) R=19.0 169.20 ft'
c. N/A R= ft2
7. Windows" Description Area R ft'
a. U-Factor: Dbl,U=0.35 210.27 ft' 11. Ducts
a.Sup:Attic,Ret:Attic,AH:Garage 6 135
SHGC: SHGC=0.29
b. U-Factor: N/A ft'
-1 SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor N/A ft2 a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ft' 13. Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 4.385 ft.
Area Weighted Average SHGC: 0.290
8. Floor Types Insulation Area 14. Hot water systems Cap:55 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1802.00 ft' a. Electric EF:0.95
b. N/A R= ft2
c. N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building . •SHE •ST •••..
Construction through the above ene ..y savingfeatures which will be installed (or exceeded) ..
in this home before final inspectio2 Otherwis•, a new EPL Display Card will be completed y, „ip, ,,E;...9.
.• „...: `:
based on installed .• pi' tfe u es , ,°;'3` ',0 t
vi
Builder Signature: �ro Date: 7 :0\ ' ,1_e_+ !a e
Address of New Home: i '`
City/FL Zip: �I✓1 /�- gad ' :.......we......` 5
G� . 33 cowl • ;.
ir
X
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/19/2017 11:01 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
•
• FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: 743 Sailfish Drive Permit Number:
Jacksonville,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section
553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A
written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3. Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems,if installed at the time of the test,shall be tumed off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
o R403.2.2 Sealing(Mandatory)111 ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7),
Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"by either of
the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
7/19/2017 11:01 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'A inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
4 . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
▪ R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code, Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
7/19/2017 11:01 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3
FORM R405-2014
• MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance fumaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
111 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
•
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
' solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously buming pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
7/19/2017 11:01 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3
• FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: 1802 Builder Name: X L Properties
Street: 743 Sailfish Drive Permit Office: City of Atlantic Beach
City,State.Zip: Jacksonville,FL, Permit Number:
Owner: Jurisdiction: 261300
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
7/19/2017 11:01 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1
Manual S Compliance Report
+{+ wriyntsoft Date:
OFFICE COPY
Entire House By:
Plan: 1802
Fl
Project Information
For: X L Properties
963 Myron Road, Fruit Cove, Fl 32259
Phone: 904-821-5200
Cooling Equipment
Design Conditions
Outdoor design DB: 92.6°F Sensible gain: 24238 Btuh Entering coil DB: 76.5°F
Outdoor design WB: 77.1°F Latent gain: 4839 Btuh Entering coil WB: 63.5°F
Indoor design DB: 75.0°F Total gain: 29077 Btuh
Indoor RH: 50% Estimated airflow: 1010 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Goodman Mfg. Model: GSZ140361 K+ASPT47D14A
Actual airflow: 1010 cfm
Sensible capacity: 28068 Btuh 116%of load
Latent capacity: 6063 Btuh 125%of load
Total capacity: 34131 Btuh 11N.of load SHR: 82%
Heating Equipment
Design Conditions
Outdoor design DB: 32.0°F Heat loss: 29478 Btuh Entering coil DB: 68.8°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Goodman Mfg. Model: GSZ140361 K+ASPT47D14A
Actual airflow: 1010 cfm
Output capacity: 34800 Btuh 118%of load Capacity balance: 31 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip REVISION
Manufacturer: Model:
Actual airflow: 1010 cfm BP# /7 - 'R - 3/77_1
Output capacity: 9.6 kW 112%of load Temp. rise: 50 °F DATE / /
Meets are all requirements of ACCA Manual S. SIGNED filf)
2017-Jul-19 10:40:15
wrightsoft Right-Suite®Universal 2017 17.0 10 RSU09479 Page 1
Ac's ...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
4 wrightsoft
Project Summary Date:
9 Entire House By:
Plan: 1802
Fl
Pro ect Information
For: X L Properties
963 Myron Road, Fruit Cove, Fl 32259
Phone: 904-821-5200
Notes: 743 Sailfish Drive
Desi. n Information
Weather: Jacksonville Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 °F Outside db 93 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 18 °F
Daily range M
Relative humidity 50 %
Moisture difference 51 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24565 Btuh Structure 20198 Btuh
Ducts 4913 Btuh Ducts 4040 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 29478 Btuh Use manufacturer's data y
Rate/swing multiplier 1.10
Infiltration Equ meet sensible-load ►.kial":tuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2685 Btuh
Ducts 2154 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 1802 1802 Eviipmnnt latent I Btuh
Volume (ft3) 14504 14504
Air changes/hour 0.38 0.20 Eoi ipment total!gad ' 60 :tuh
Equiv.AVF (cfm) 92 48 Req.tonal capacity at 0.70 SHR 2.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Goodman Mfg. Make Goodman Mfg.
Trade GOODMAN; JANITROL;AMANA DISTI... Trade GOODMAN; JANITROL;AMANA DISTI...
Model GSZ140361 K Cond GSZ140361 K
AHRI ref 8242629 Coil ASPT47D14A
AHRI ref 8242629
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 24360 Btuh
Heating output 32600 Btuh @ 47°F Latent cooling 10440 Btuh
Temperature rise 29 °F Total cooling 34800 Btuh
Actual air flow 1010 cfm Actual air flow 1010 cfm
Air flow factor 0.034 cfm/Btuh Air flow factor 0.042 cfm/Btuh
Static pressure 0.25 in H2O Static pressure 0.25 in H2O
Space thermostat Load sensible heat ratio 0.83
Capacity balance point=31 °F
Backup:
Input= 10 kW, Output=32924 Btuh, 100 AFUE
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
_ �.�'.�,y. W rl htsoft2017-Jul-19 10:40.15
-f' 9 Right-Suite®U niversal 2017 17.0.10 RSU09479 Page 1
fk--`---A ...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
+}+- wrightsoft Right-J® Worksheet Job:
Entire House Date.
e :
Plan: 1802
Fl
1 Room name Entire House Room1
2 Exposed wall 224.8 ft 49.0 ft
3 Room height 8.6 ft 8.0 ft uncondit.
4 Room dimensions 1.0 x 460.0 ft
5 Room area 2120.0 f t' 460.0 f I'
I I I r r i
Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') Load
I
number (Btuh/ft'-'F (Btuh/ftl or perimeter (ft) I
(Btuh) or perimeter (ft) (8tuh)
IHeat I Cool Gross NIP/S Heat I Cool Gross I N/P/S Heat I Cool
6 VJ 12C-Osw 0.091 n 3.46 2.29 463 395 1366 906 0 0 0 0
. -0 1 Dc2ob 0.650 n 24.70 20.87 8 0 198 167 0 0 0 0
. -(' 1D-c2ob 0.650 n 24.70 20.87 30 0 741 626 0 0 0 0
1D-c2ob 0.850 n 24.70 20.87 30 0 741 626 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 24 24 62 34 0 0 0 0
V)J 12C-Osw 0.091 ne 3.46 2.29 28 9 31 21 0 0 0 0
t C 10B-b 0.750 ne 28.50 26.68 19 0 549 514 0 0 0 0
VJ 12C-Osw 0.091 e 2.89 1.92 431 393 1138 754 64 64 0 0
-G 1 D-c2ob 0.650 e 24.70 61.55 8 0 198 492 0 0 0 0
-G 1D-c2ob 0.650 e 24.70 61.55 30 0 741 1846 0 0 0 0
b
12C-Osw 0.091 s 1.75 1.16 423 357 625 414 176 176 0 0
1D-c2ob 0.650 s 24.70 20.87 30 60 741 626 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 16 32 395 334 0 0 0 0
11 DO 0.390 s 14.82 11.78 20 20 302 240 0 0 0 0
W 12E-Osw 0.068 s 2.58 1.43 48 48 124 69 0 0 0 0
VJ 12C-Osw 0.091 w 2.06 1.37 416 377 778 516 152 152 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 9 0 222 554 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 30 0 741 1846 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 24 24 62 34 0 0 0 0
12C-Osw 0.091 - 3.46 1.39 364 345 1192 480 0 0 0 0
D 1100 0.390 n 14.82 11.78 19 19 286 227 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 346 346 1065 1505 0 0 0 0
C 168-19ad 0.049 - 1.86 2.63 352 352 655 926 0 0 0 0
C 16B-30ad 0.032 - 0.82 1.16 1422 1422 1170 1653 460 460 0 0
F 22A-tpl 0.989 - 29.39 0.00 2120 225 6607 0 460 49 0 0
6I c)AED excursion I I I 20730 I 0 I O
1 Envelope loss/gain 1 15413 0 0
12 a) Infiltration 3836 935 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants g 230 5 1150 0 0
Appliances/other 2700 0
Subtotal(lines 6 to 13) 24565 20198 0 0
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 24565 20198 0 0
15 Duct loads 20% 20% 4913 4040 0% 0% 0 0
1 Tztarel qr7iirmedlo(ad ) I 1 1 2941071801
2412038101
40 O 1 1 1 0°1 001
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsof[ 2017-Jul-19 10:40:15
Right-Suite®Universal 2017 17.0.10 RSU09479 Page 1
...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
•
+}.1- wrightsoft Right-J® Worksheet Job:
Entire House Date:
By:
Pfan: 1802
Fl
1• Room name Laundry Master
2• Exposed wall 12.0 ft 13.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 1.0 x 56.0 ft 14.0 x 13.0 ft
5 Room area 56.0 ft' 182.0 (t'
r I I I r
Ty Construction U-value Or HTM Area (ft') Load Area (ft' Load
T number (Btuh/ft'-°F) I (Btuh/ft') I or perimeter (ft) 1I (Btuh) I or perimeter (ft) (Btuh)
Heat I Cool I Gross N/P/S Heat I Cool I Gross N/P/S I Heat I Cool
6 W12C-Osw 0.091 n 3.46 2.29 0 0 0 0 0 0 0 0
. -G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
. -G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0 0 0 0 0
r_G12C-Osw 0.091 ne 3.46 2.29 0 0 0 0 0 0 0 0
10B-b 0.750 ne 28.50 26.68 0 0 0 0 0 0 0 0
W 12C-Osw 0.091 e 2.89 1.92 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
12C-Osw 0.091 s 1.75 1.16 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
D
1100 0.390 s 14.82 11.78 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 s 2.58 1.43 48 48 124 69 0 0 0 0
W 12C-Osw 0.091 w 2.06 1.37 48 39 135 89 104 74 256 170
-G 1D-c2ob 0.650 w 24.70 61.55 9 0 222 554 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 30 0 741 1846
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0 0 0 0 0
112C-Osw 0.091 - 3.46 1.39 56 56 194 78 0 0 0 0
D 1100 0.390 n 14.82 11.78 0 0 0 0 0 0 0 0
C 168-11ad 0.081 - 3.08 4.35 0 0 0 0 0 0 0 0
C 168-19ad 0.049 - 1.86 2.63 0 0 0 0 0 0 0 0
C 168-30ad 0.032 - 0.82 1.16 56 56 68 96 182 182 221 313
F 22A-tpl 0.989 - 29.39 0.00 56 12 451 0 182 13 489 0
6 c)AED excursion 136 694
Envelope loss/gain I 11941 1022 I 17071 3023
12 a) Infiltration 251 61 272 66
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 2 460
Appliances/other 600 0
Subtotal(lines 6 to 13) 1445 1683 1979 3549
Less extemal load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1445 1683 1979 3549
15 Duct loads 20% 20% 289 337 20% 20% 396 710
I Air eql
ed ) I I I 1734
591 20201
84 I I 2375
81 1 4179)
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft 2017-Jul-19 10:40:15
Right-Suite®Universal 2017 17.0.10 RSU09479 Page 2
^A' ...Air DesignsV(L Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
+if wrightsoft Right-J® Worksheet Job:
Entire House Date:
ey
Pla:n: 1802
Fl
1 Room name M Toilet M Bath
2 Exposed wall 5.0 ft 14.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 3.0 x 5.0 ft 1.0 x 73.0 ft
5 Room area 15.0 ft' 73.0 ft'
I I I I r i
Ty Construction U-value OrHTM Area (ft') Load Area (ft') Load
number (Btuh/ft'-°F I (Btuh/ft') I or perimeter (ft) (Btuh) or or perimeter (ft) (Btuh)
Heat I Cool Gross I N/P/S I Heat I Cool I Gross 1 N/P/S Heat {I Cool I
6 VJ 12C-Osw 0.091 n 3.46 2.29 0 0 0 0 64 56 194 128
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 8 0 198 167
. -G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0 24 24 62 34
W 12C-Osw 0.091 ne 3.46 2.29 0 0 0 0 0 0 0 0
t G, 109-b 0.750 ne 28.50 26.68 0 0 0 0 0 0 0 0
1.6 12C-Osw 0.091 e 2.89 1.92 0 0 0 0 0 0 0 0
10-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
‘/111 12C-Osw 0.091 s 1.75 1.16 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
D
11D0 0.390 s 14.82 11.78 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 s 2.58 1.43 0 0 0 0 0 0 0 0
VJ 12C-Osw 0,091 w 2.06 1.37 40 40 138 92 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
-(' 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0 24 24 62 34
12C-Osw 0.091 - 3.46 1.39 0 0 0 0 0 0 0 0
D 1100 0.390 n 14.82 11.78 0 0 0 0 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 0 0 0 0 0 0 0 0
C 16B-19ad 0.049 - 1.86 2.63 0 0 0 0 0 0 0 0
C 166-30ad 0.032 - 0.82 1.16 15 15 18 26 73 73 89 125
F 22A-tpl 0.989 - 29.39 0.00 15 5 188 0 73 14 526 0
61 c)AED excursion I I I 591
Envelope loss/gain 344 102 1 1130 431
12 a) Infiltration 105 26 293 71
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 449 128 1423 502
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 449 128 1423 502
15 Duct loads 20% 20% 90 26 20% 20% 285 100
I TAiortareql
uuired( )
I l I I 5 1
181 1541
I I 17059 81 6251
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
��-.,,, "4- wrightsoft 2017-Jul-1910:40:15
Right-Suite®Universal 2017 17.0.10 RSU09479 Page 3
...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
4 wrightsoft Right-J® Worksheet Job:
Entire House Date:
By:
Plan: 1802
Fl
1 Room name M WIC Dining
2 Exposed wall 6.0 ft 18.0 ft
3 Room height 8.0 ft heat/cool 9.0 ft heat/cool
4 Room dimensions 6.0 x 8.0 ft 11.0 x 8.0 ft
5 Room area 48.0 ft' 88.0 ft'
I I r I r
Ty Construction U-value Or I HTM Area (ft') Load 1 Area (ft') Load
number (Btuh/ft'-'F (Btuh/ft') 1 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat I Cool f Gross NIP/S I Heat 1 Cool C Gross I N/P/S Heat I Cool
6 VI 12C-Osw 0.091 n 3.462.29 48 48 166 110 99 69 239 158
. ---G 1 D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
. --moi 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 30 0 741 626
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0 0 0 0 0
VI/ 12C-Osw 0.091 ne 3.46 2.29 0 0 0 0 0 0 0 0
I G 10B-b 0.750 ne 28.50 26.68 0 0 0 0 0 0 0 0
W 12C-Osw 0.091 e 2.89 1.92 0 0 0 0 63 63 218 144
-G 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
-C 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
12C-Osw 0.091 s 1.75 1.16 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
D
11D0 0.390 S 14.82 11.78 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 S 2.58 1.43 0 0 0 0 0 0 0 0
VJ 12C-Osw 0.091 w 2.06 1.37 0 0 0 0 0 0 0 0
-(' 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0 0 0 0 0
R 12C-Osw 0.091 - 3.46 1.39 0 0 0 0 0 0 0 0
D 11D0 0.390 n 14.82 11.78 0 0 0 0 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 0 0 0 0 0 0 0 0
C 16B-19ad 0.049 - 1.86 2.63 0 0 0 0 88 88 164 232
C 166-30ad 0.032 - 0.82 1.16 48 48 58 82 0 0 0 0
F 22A-tpl 0.989 - 29.39 0.00 48 6 225 0 88 18 676 0
6I c)AED excursion I 23� ( ( 133I
1 Envelope loss gain 450 169 2038 1028
12 a) Infiltration 126 31 424 103
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 575 200 2462 1131
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 575 200 2462 1131
15 Duct loads 20% 20% 115 40 20% 20% 492 226
l
TotalArrequiroomred load(cfm)
I I I 691 2401 l I 2954 I 13581
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Jul-19 10:40:15
t wrightsoft Right-Suite®Universa1207717.0.10RSU09479
Ar_. ,A. Page 4
...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
4 wrightsoft Right-J® Worksheet Job:
Entire House Date.
By:
Plan: 1802
Fl
1 Room name Kitchen Great Room
2 Exposed wall 0 ft 16.8 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 1.0 x 180.0 ft 1.0 x 346.0 ft
5 Room area 180.0 ft° 346.0 ft'
i I T I I I I
Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load
number (Btuhlft'-5F I (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
+
Heat I Cool Gross N/P/S Heat I Cool I Gross I N/P/S Heat I Cool
6 VI 12C-Osw 0.091 n 3.46 2.29 0 0 0 0 140 110 380 252
---G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
--G 1 Dc2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 30 0 741 626
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0 0 0 0 0
V)/ 12C-Osw 0.091 ne 3.46 2.29 0 0 0 0 28 9 31 21
L� 106-b 0.750 ne 28.50 26.68 0 0 0 0 19 0 549 514
W 12C-Osw 0.091 e 2.89 1.92 0 0 0 0 0 0 0 0
-0 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
b
12C-Osw 0.091 s 1.75 1.16 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
11D0 0.390 s 14.82 11.78 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 s 2.58 1.43 0 0 0 0 0 0 0 0
W 12C-Osw 0,091 w 2.06 1.37 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0 0 0 0 0
I 12C-Osw 0.091 - 3.46 1.39 160 141 487 196 40 40 138 56
D 11D0 0.390 n 14.82 11.78 19 19 286 227 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 0 0 0 0 346 346 1065 1505
C 16B-19ad 0.049 - 1.86 2.63 180 180 335 474 0 0 0 0
C 16B-30ad 0.032 - 0.82 1.16 0 0 0 0 0 0 0 0
F 22A-tpl 0.989 - 29.39 0.00 180 0 0 0 346 17 632 0
6 c)AED excursion -220 -418
Envelope loss/gain I 1107 6771 35371 2556
12 a) Infiltration 0 0 441 107
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 1200 900
Subtotal(lines 6 to 13) 1107 1877 3977 3564
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 16 20
14 Subtotal 1107 1877 3993 3584
15 Duct loads 20% 20% 221 375 20% 20% 799 717
I I TAiortarecil
roouirmedlo(ad
) I I I 13461 22521
94 I I 4792
1641 41791
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-014- wo
ri htsft 2017-Jul-19 10:40:15
n' F 9 Right-Suite3>U r iversal 2017 17.0.10 RSU09479 Page s
...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
4 wrightsoft Right-J® Worksheet Job:
Entire House Date:
By:
Plan: 1802
FI
1 Room name Foyer Bed 4
2 Exposed wall 7.0 ft 12.0 ft
3 Room height 9.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 7.0 x 12.0 ft 12.0 x 12.0 ft
5 Room area 84.0 f t' 144.0 f t'
t I r r r
Ty Construction U-value Or I HTM I Area (ft') Load I Area (ft') Load
number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
IHeat 1 Cool 1 Gross I N/P/S Heat f Cool I Gross I N/P/S Heat I Cool
6 V/ 12C-Osw 0.091 n 3.46 2.29 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
. --G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0 0 0 0 0
W 12C-Osw 0.091 ne 3.46 2.29 0 0 0 0 0 0 0 0
L-{ 10B-b 0.750 ne 28.50 26.68 0 0 0 0 0 0 0 0
VI 12C-Osw 0.091 e 2.89 1.92 0 0 0 0 0 0 0 0
--C 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
12C-Osw 0.091 s 1.75 1.16 63 27 92 61 96 66 228 151
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 30 30 741 626
1D-c2ob 0.650 s 24.70 20.87 16 16 395 334 0 0 0 0
D
11D0 0.390 s 14.82 11.78 20 20 302 240 0 0 0 0
W 12E-Osw 0.068 s 2.58 1.43 0 0 0 0 0 0 0 0
W 12C-Osw 0.091 w 2.06 1.37 0 0 0 0 0 0 0 0
G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0 0 0 0 0
R 12C-Osw 0.091 3.46 1.39 108 108 373 150 0 0 0 0
D 11D0 0.390 n 14.82 11.78 0 0 0 0 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 0 0 0 0 0 0 0 0
C 168-19ad 0.049 - 1.86 2.63 84 84 156 221 0 0 0 0
C 1613-30ad 0.032 - 0.82 1.16 0 0 0 0 144 144 175 247
F 22A-tpl 0.989 - 29.39 0.00 84 7 263 0 144 12 451 0
6 c)AED excursion I 1101 I -138
Envelope loss/gain 1582 897 •
1595 887
12 a) Infiltration 165 40 251 61
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 1747 937 1847 1178
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 4 5
14 Subtotal 1747 937 1851 1184
15 Duct loads 20% 20% 349 187 20% 20% 370 237
I I TAir regoomdload I I I 20971 1147 I I 22761 14591
Calculations approved by ACCA to meet all requirements of Manual J $th Ed.
" wrightsoft 2017-Jul-19 10:40:15
Right-Suite®U niversal 2017 17.0.10 RSU09479 Page 6
4 `~`�' ...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
-+}- wrightsoft Right-J® Worksheet Job:
Entire House Date:
syy:
Pfan: 1802
FI
1 Room name WIC 4 Bed 3
2 Exposed wall 11.0 ft 19.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 6.0 x 5.0 ft 11.0 x 14.0 ft
5 Room area 30.0 ft' 154.0 ft'
I I I I r
Ty Construction U-value Or HTM Area (ft') Load I Area (ft') Load
number (Btuh/ft'-°F) II (Btuh/it) I or perimeter (ft) 1I (Btuh) or perimeter (ft) (Btuh)
I
Heat I Cool I Gross I N/P/S I Heat I Cool I Gross I N/P/S I Heat I Cool I
6 W 12C-Osw 0.091 n 3.46 t 2.29 0 0 0 0 0 0 0 0
. -G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
. -G 1 D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0 0 0 0 0
V)/ 12C-Osw 0.091 ne 3.46 2.29 0 0 0 0 0 0 0 0
L-( 10B-b 0.750 ne 28.50 26.68 0 0 0 0 0 0 0 0
W 12C-Osw 0.091 e 2.89 1.92 40 40 138 92 112 97 335 222
-G 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0 0 0 0 0
-C 1 D-c2ob 0.650 e 24.70 61.55 0 0 0 0 15 0 370 923
bt 2C-Osw 0.091 s 1.75 1.16 48 48 166 110 40 40 138 92
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
11D0 0.390 s 14.82 11.78 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 s 2.58 1.43 0 0 0 0 0 0 0 0
VI 12C-Osw 0.091 w 2.06 1.37 0 0 0 0 0 0 0 0
-moi 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0 0 0 0 0
I 12C-Osw 0.091 - 3.46 1.39 0 0 0 0 0 0 0 0
D 1100 0.390 n 14.82 11.78 0 0 0 0 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 0 0 0 0 0 0 0 0
C 16B-19ad 0.049 - 1.86 2.63 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 0.82 1.16 30 30 36 52 154 154 187 265
F 22A-tpl 0.989 - 29.39 0.00 30 11 413 0 154 19 714 0
6I c)AED excursion I I
I 32II131Envelope losslgain 754 221 1 17461 1637
12 a) Infiltration 230 56 398 97
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants.Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 985 277 2143 1964
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 10 13
14 Subtotal 985 277 2153 1976
15 Duct loads 20% 20% 197 55 20% 20% 431 395
Air
Total roomrequired load(cirn)
I I 11401 332 I I 2584 2372 I l
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
_ wrightsoft Right-Suite®Universal 2017 17.0.10 RSU09479 2017-Jul-19 10:40:15
Page
7
"n- ...Air Designs VXL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S 9
' wrightsoft Right-J® Worksheet Job:
Entire House Date.
By:
Plan: 1802
Fl
1 Room name Bath Bed 2
2 Exposed wall 5.0 ft 37.0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 11.0 x 5.0 ft 1.0 x 172.0 ft
5 Room area 55.0 ft' 172.0 f t'
r
' ' I
Ty Construction U-value Or I HTMI Area (ft') Load I Area (ft') Load
number (Btuh/ft'-°F (Btuh/ftl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
I
Heat Cool Gross I NIP/S Heat I Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 3.46 2.29 0 0 0 0 112 112 387 257
-G 1 D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0 0 0 0 0
W 12C-Osw 0.091 ne 3.46 2.29 0 0 0 0 0 0 0 0
L_( 10B-b 0.750 ne 28.50 26.68 0 0 0 0 0 0 0 0
W 120-05w 0.091 e 2.89 1.92 40 32 111 73 112 97 335 222
--G 1 D-c2ob
--G 1D-c2ob
0.650 e 24.70 61.55 8 0 198 492 0 0 0 0
b
e 24.70 61.55 0 0 0 0 15 0 370 923
12C-0sw 0.091 s 1.75 1.16 0 0 0 0 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
IDc2ob 0.650 s 24.70 20.87 0 0 0 0 0 0 0 0
11 DO 0.390 s 14.82 11.78 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 s 2.58 1.43 0 0 0 0 0 0 0 0
W 12C-0sw 0.091 w 2.06 1.37 0 0 0 0 72 72 249 165
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0 0 0 0 0
R 12C-0sw 0.091 3.46 1.39 0 0 0 0 0 0 0 0
0 11D0 0.390 n 14.82 11.78 0 0 0 0 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 0 0 0 0 0 0 0 0
C 16B-19ad 0.049 - 1.86 2.63 0 0 0 0 0 0 0 0
C 16B-30ad 0.032 - 0.82 1.16 55 55 67 95 172 172 209 296
F 22A-tpl 0.989 - 29.39 0.00 55 5 188 0 172 37 1391 0
excuion
102
6 Envelope loss/gain 1 1 5631 7621 1 2942119501
12 a) Infiltration 105 26 775 189
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 668 788 3717 2369
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 6 7 4 5
14 Subtotal 673 795 3721 2375
15 Duct loads 20% 20% 135 159 20% 20% 744 475
I TAirotalrequireroom
d load(cfm)
1 1 1 8081 9541 1 1 44651 28501
28 40 153 119
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Jul-19 10:40:15
_ _ wrightsoft Right-Suite)Universal 201717.0.10 RSU09479 Page8
R ...Air Designs\XL Properties1743 Sailfish11802.rup Calc=MJ8 Front Door faces: S
+}+ wrightsoft Right-J® Worksheet Job:
Entire House Date:
By:
Plan: 1802
FI
1 Room name Hall
2 Exposed wall 0 ft
3 Room height 8.0 ft heat/cool
4 Room dimensions 3.0 x 11.0 ft
5 Room area 33.0 ft'
I I I I t
Ty Construction U-value Or I HTMI Area (ft') Load Area I Load i
number (Bt uh/ft'-'F (Btuh/ft') or perimeter (ft) (Btuh) I or perimeter
Heat I Cool Gross I N/P/S Heat I Cool I Gross I N/P/S I Heat I Cool
6 VI 12C-Osw 0.091 n 3.46 2.29 0 0 0 0
-G 1 D-c2ob 0.650 n 24.70 20.87 0 0 0 0
-G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0
--G 1D-c2ob 0.650 n 24.70 20.87 0 0 0 0
11 W 12E-Osw 0.068 n 2.58 1.43 0 0 0 0
VJ 12C-Osw 0.091 ne 3.46 229 0 0 0 0
-G 10B-b 0.750 ne 28.50 26.68 0 0 0 0
W 12C-Osw 0.091 e 2.89 1.92 0 0 0 0
--C 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0
--G 1D-c2ob 0.650 e 24.70 61.55 0 0 0 0
12C-Osw 0.091 s 1.75 1.16 0 0 0 0
b
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0
1D-c2ob 0.650 s 24.70 20.87 0 0 0 0
1100 0.390 s 14.82 11.78 0 0 0 0
V/ 12E-Osw 0.068 s 2.58 1.43 0 0 0 0
VI 12C-Osw 0.091 w 2.06 1.37 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0
-G 1D-c2ob 0.650 w 24.70 61.55 0 0 0 0
W 12E-Osw 0.068 w 2.58 1.43 0 0 0 0
FI 12C-Osw 0.091 - 3.46 1.39 0 0 0 0
D 11D0 0.390 n 14.82 11.78 0 0 0 0
C 16B-11ad 0.081 - 3.08 4.35 0 0 0 0
C 16B-19ad 0.049 - 1.86 2.63 0 0 0 0
C 168-30ad 0.032 - 0.82 1.16 33 33 40 57
F 22A-tpl 0.989 - 29.39 0.00 33 0 0 0
6 c)AED excursion
1 -6
Envelope loss/gain 401 51
12 a) Infiltration 0 0
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 40 51
Less external load 0 0
Less transfer 0 0
Redistribution -40 -51
14 Subtotal 0 0
15 Duct loads 20% 20% 0 0
Il
I TA ortalrequirroomed(dloadm)
I I l 001
01
I I l
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
++F wrightsof`t 2017-Jul-1910:40:15
Right-Suite Universal 2017 17.0.10 RSU09479 Page 9
` .Air DesignslXL Propertiesl743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
•N
\ 7
/I ,
1st Floor
''4 18 dm M Bath M WIC Dining
M Toilet
1"
-1 �_� �
59 dm 24 dm 101 dm
ii Bed
4. 6 6 4" i I.
6"
11 8'dm
1
12 x 12 .'4 153 cfm
■
Master f
40 dm
1. Bath
V6" Kitchen Great Room 12"
6" 8"
• 7"
12'
'.' 16x16 10' 4"
` 4
jit.th..
� x 12
�� 7. 12'
.4 dm •. 62.d �4 90 elm •-1 90 dm
Laundry IL it: 7 6- •
V �l
.11;111110111.11111111111111111
"�
I,'; Bed 3
14"
6- 12x12 99dm
4"
111 72 dm *y. 76 dm
f oyer Bed 4
-k1 40 dm
Room1 .—.1-1 WIC 4
Job#: Scale: 1 : 97
Performed for: Page 1
X L Properties Right-Suite®Universal 2017
963 Myron Road Fl 17.0.10 RSU09479
Fruit Cove,Ft 32259 2017-Jul-19 10:40:59
Phone 904-821-5200 ...Properties\743 Sailfish11802.rup
4 wrightsoft
Duct System Summary Date:
Entire House By:
Plan: 1802
FI
Project Information
For: X L Properties
963 Myron Road, Fruit Cove, Fl 32259
Phone:904-821-5200
Heating Cooling
External static pressure 0.25 in H2O 0.25 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.25 in H2O 0.25 in H2O
Supply/return available pressure 0.186/0.064 in H2O 0.186/0.064 in H2O
Lowest friction rate 0.100 in/100ft 0.100 in/100ft
Actual air flow 1010 cfm 1010 cfm
Total effective length (TEL) 196 ft
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk
Bath c 954 28 40 0.100 4.0 Ox 0 VIFx 40.2 100.0 st3
Bed 2 h 4465 153 119 0.100 7.0 Ox 0 VIFx 45.5 100.0 st3
Bed 3 c 2372 89 99 0.100 6.0 Ox 0 VIFx 37.3 100.0 st3
Bed 4 h 2221 76 59 0.100 6.0 Ox 0 VIFx 26.8 85.0 st2
Dining h 2954 101 57 0.100 6.0 Ox 0 VIFx 23.2 85.0 st1
Foyer h 2097 72 47 0.100 4.0 Ox 0 VIFx 20.1 85.0 st2
Great Room c 2150 82 90 0.100 7.0 Ox 0 VIFx 25.5 85.0 st2
Great Room-A c 2150 82 90 0.100 7.0 Ox 0 VIFx 19.6 85.0 st2
Kitchen c 2252 46 94 0.100 6.0 Ox 0 VIFx 5.7 70.0
Laundry c 2020 59 84 0.100 6.0 Ox 0 VIFx 22.5 85.0 st1
M Bath h 1708 59 25 0.100 6.0 Ox 0 VIFx 21.2 85.0 st1
M Toilet h 539 18 6 0.100 4.0 Ox 0 VIFx 26.8 85.0 st1
M wlc h 691 24 10 0.100 4.0 Ox 0 VIFx 19.2 85.0 st1
Master c 2130 41 89 0.100 6.0 Ox 0 VIFx 15.3 85.0 st1
Master-A c 2130 41 89 0.100 6.0 Ox 0 VIFx 14.3 85.0 st1
WIC 4 h 1181 40 14 0.100 4.0 Ox 0 VIFx 45.2 100.0 st3
Supply Trunk Detail Table
Trunk Htg CIg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st1 Peak AVF 343 360 0.100 458 12.0 0 x 0 VinIFIx
st2 Peak AVF 622 556 0.100 582 14.0 0 x 0 VinIFIx
st3 Peak AVF 310 271 0.100 568 10.0 0 x 0 ViniFlx st2
Bold/italic values have been manually overridden
2017-Jul-19 10.40:16
L wrightsoft Right-Suite®Universal 2017 17 0.10 RSU09479 Page 1
,4:G0. ...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk
rsb5 Ox 0 388 454 50.1 0.080 578 12.0 Ox 0 VIFx
rb2 Ox 0 622 556 33.6 0.080 582 14.0 Ox 0 VIFx
2017-Jul-19 10:40:16
wrightsoft Right-Suite®Universal 2017 17.0.10 RSU09479 Page 2
/9".---,-,", ...Air Designs\XL Properties\743 Sailfish\1802.rup Calc=MJ8 Front Door faces: S