Loading...
1390 ROSE ST - EXTEND ROOF DRAWINGS002 LLIQ 0 C7 3 SPLICE NEW ROOF JOIST 2x6 SYP#2 2'-0" MIN. FASTEN TO EXISTING STRUCTURAL PLAN NOTES: ROOF TRUSS w/12d COMMON 1. PORCH BEAMS TO POST W/ (2) MSTA24 STRAPS. 2x6 SYP#2 ROOF WIRE NAILS 4" O.C. STAGGERED JOIST ® 24" O.C. 2. ROOF SHEATHING SHALL BE APA RATED 'die" MIN ATTACH W/ 8d NEW 6x6 SYP2 PT i ' EXISTING ROOF RINGSHANK NAILS SPACING ® POST W/ ABU SIMPSON -` IST OR TRUSS z 1. 12" o/c FIELD & 6" o/c EDGES INTERIOR ZONE ——I H2.5A UPLIFT40 REMAIN � 2. 6" o/c FIELD & 6" o/c EDGES PERIMETER ZONEa I CONNECTOR 3. 4" o/c FIELD & 4 ofo c EDGES GABLE ENDS Flo I— —) U FOUNDATION PLAN NOTES: p 1. REFER TO FLOOR PLAN FOR ANY ADDITIONAL WALL NEW 6x6 SYP2 PT NEW 6x6 SYP2 PT LOCATIONS AND DIMENSIONS. POST W/ ABU POST W/ ABU 2. CONTRACTOR TO NOTIFY ENGINEER OF RECORD IMMEDIATELY INI _ I HEADER BEAM S WRITING IF DISCREPANCIES FOUND BETWEEN FIELD CONDITIONS AND ENGINEERING PLAN. F2.0 I_— J F2.0 (—— —I F2.0 I—— F2.0 I—— F2.0 L__ F2.0 L_— SEE PLAN CONVENTIONAL FRAMING NOTES: EW 6x6 SYP#2 NEW 6x6 SYP#2 NEW 6x6 SYP#2 NEW 6x6 SYP#2 Z � 1. ALL MATERIAL TO BE #2 SYP UNO. P.T. POST P.T. POST P.T. POST P.T. POST w o / ABU66 W/ ABU66 W/ ABU66 W/ ABU66 BEAM TO POST WOR A 2. ALL RAFTERS 2x6 #2 SYP ® 24" o.c., UNO. FASTEN w/H2.5A FOUNDATION PLAN FASTEN w/ ' g o TO PLATE UNO. of , „ W w N H X _� _D (2)MTSA24 " C � w � w 3. (4) 0.131x3" TOENAILS RAFTER TO PLATE. p < 5 � coNQ U. 0 Q N � U POST PER J LAN ANCHOR EMBED/EPDXIED ;'� ° W/ SET-XP 7" MIN iz a� - Existing (12) 16d COMMON ~ EXISTING VERIFY BRG HIST TOEXTERIOPOST uQ�' (2)2x12 SYP#2 cMu wARI •. FOR CLARITY ONLY. VERIFY AL XISTING NEW SLAB EXISTING 4t P �0 EXISTING STRUCTURES ARE SHOWN ON DRAWINGS 0 CL 0 L L E ELEVATIONS AND TYPE OF CONSTRUCTION OF THOSE STRUCTURES, AND NOTIFY ENGINEER ! ttil���t�°� LL- IMMEDIATELY BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES a .A F2.0 CONC. FOOTING THAT MIGHT EXIST BETWEEN CONSTRUCTION DOCUMENTS AND/OR ACTUAL FIELD CONDITIONS. ° ' ' 29x2'x1O" DEEP w/ THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND ° • ° OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY a� 3#-4 EA,WAY BOT PERSONNEL DURING CONSTRUCTION. THE DESIGN ADEQUACY AND SAFETY OF ABOVE ITEMS ARE THE New Porch 44 SOLE RESPONSIBILITY OF THE CONTRACTOR. VAULTED CEILING SECTION (2)2x12 SYP#2 (2)2x12 SYP#2 (2)2x12 SYP#2 (2)2x12 S (2)2x12 SYP#2 S2 SCALE: 3/4" = 1'-0" NOTE: LVL 2.0E MIN UNO (2) ROWS 16d 0 (3) ROWS 16d 12" o/c EA SIDE 12" o/c EA SIDE LI J W U •�,-?� W 2-PLY BEAM "{3c-PLY BEAM STRUCTURAL PLAN U) „_1 y4Q,_off (2) ROWS 1/4x3-1/2" N Z SDS SREWS 12" o c O EA SIDE _) +@ U J cn 4–PLY BEAM Z BUILT—UP BEAM DETAIL � v U of rz > 1-1/2" BUILT-UP COLUMN NOTES: 1. TYPICAL CONNECTION FOR o N STUD COLUMNS, JACK TO EX STIN KING STUD ASSEMBLIES, & : CORNER POSTS. ° 2x ROW E 1: H USE 2?c4 MEMBERS STING NAILS ® 6" O.C. TERIOR 2. CONNECTION REQUIRED ° STAGGEREDMu WALL FOR EVERY PLY IN ADDITION o TO 2-PLYS. 2x6 MEMBERS: 11 11 IL III 111 11 1 1 1 1 1 1 1 (1) ROW OF 1 Odw ° NAILS ® 4" O.C. STAGGEREDpo po O o ro 2x8 MEMBERS: X 0 uj U P= Q (1) ROW OF 10d° 0 NAILS ® 3 O.C. > W ° STAGGERED U o 20 SYP2 OR 2x6 SYP2 O W L� W EDGE OF APX. BUILT—UP COLUMN DETAIL ROOF RAFTER FRAME ROOF �- U FRAMF � Q ADJJST OVERHANG AS Li NECESSARY IN THE FIELD (TYP) Ld m (n U F— 00:� F— 0 Z Q O Q Q � Q DRAWN BY 0 VEN TION AL ROOFPLAN AOB y4„—i,—o» DATE 8 23 2016 SCALE AS NOTED DESIGNED BY DVL JOB No. 160504 SHEET No. S20F 2