Loading...
1762 ATLANTIC BEACH DR - SFR PERMIT d , CITY OF ATLANTIC BEACH �: :. s) 800 SEMINOLE ROAD �`41: . ATLANTIC BEACH, FL 32233 ____ )rm 9• INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0128 Description: NEW SINGLE FAMILY Estimated Value: 397461.4 Issue Date: 9/6/2017 Expiration Date: 3/5/2018 PROPERTY ADDRESS: Address: 1762 ATLANTIC BEACH DR RE Number: 169505 1650 PROPERTY OWNER: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: TOLL FL VI LIMITED PARTNERSHIP 1 Address: 250 GIBRALTAR RD HORSHAM, PA 19044 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work 0 exceeds and estimated value of$7,500. 4 0.Lpp;� City of Atlantic Beach APPLICATION NUMBER jt Pe-40K4 Building Department (To be assigned by the Building Department.) :. `'.A \,;.; 800 Seminole Road. jj !, 7 ,j � Atlantic Beach, Florda 32233-5445 `�ES t 7 -U t _ j Phone(904)247-5826 • Fax(904)247-5845 Q P...01 0 E-mail: building-dept@coab.us Date routed: (�/4 l( 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 76Z `-iQ1L` (C' 30XL1-\ Department review required Ye No Applicant: 1-0 t C c-•- E-osnmg &Zoni'nZg'-, \ 11 Tree Adminis ra or Project: 6 )Cts S i n 1 Eorv' t is Works c iiies‘N Public Safety Fire Services Review fee $ _ . Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District 4 Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ❑Denied. ❑Not applicable (C. - one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: 2.1 F-17 TREE ADMIN. Second Review: A roved as revised. Denis d. ❑ Pp ❑ ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. EDenied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 • Building Permit Application OFFICE COPY City of Atlantic Beach r 800 Seminole Road,Atlantic Beach, FL 32233 a 0" Phone: (904) 247-5826 Fax: (904) 247-5845 Job Address: 1762 Atlantic Beach Drive Permit Number: RCSi7 V ( Legal Description Lot 71 Atlantic Beach Country Club Unit 2, 67-132 08-2S-29E.155 RE# 169505-1650 Valuation of Work(Replacement Cost)$ 360,539.00 Heated/Cooled SF 3076 Non-Heated/Cooled 1019 • Class of Work(Circle one New Addition Alteration Repair Mo Demo •ool Window/Door • Use of existing/propose ructure(s)(Circle one): Commercia Residential , • If an existing structure,is a fire sprinkler system installed?(Circle on• . 'es No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit o o Tree Removal Describe in detail the type of work to be performed: New home construction. Florida Product Approval# See attached. for multiple products use product approval form Property Owner Information Name: TOLL FL VI LIMITED PARTNERSHIP Address: 160 Cape May Avenue City Ponte Vedra State FL zip32081 Phone 904-217-0739 E-Mail btallman@tollbrothers.com Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) TOLL FL VI, LP Contractor Information Name of Company: Toll Bros., Inc. Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue city I onte-Vedra State FL zip 32081 Office Phone 904-217-3852 Job Site/Contact Number 904-386-6472 State Certification/Registration# CGC1510225 E-Mail btallman@tollbrothers.com Architect Name&Phone# Toll Architecture (407) 248-5800 Engineer's Name&Phone# Lou Pontigo & Associates (904) 242-0908 Workers Compensation Policy#MWC30267702 / Expires: 9/1/2017 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYI►. TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANAr , CONSULT WITH YOUR LENDER OR AN ATTORNEY : FORE RECORDING YO • :i' ITICE OF COMMENCEMENT. (Sig :ture wner or Agent including Contractor) Sig of Contractor) Si d and orn o(or affirmed)before me this 25 day of Si ,d and sworn ,. (or. rmed)before me this Z5 day of ,1 l c1O/7 ,by S ' ' ,DI✓Sl?� �wl ,�I , by StLve Mr .ul, iUll/ ,.$liP J , 4g1,:ture of Notary) ature of Notary) ,.• arn�'• c;'"e MEI-ISS.4 LIcc'ET AN MELISSA LIEBERMAN �� ` R c°= r s MY COMMISSION 4FF055605 Per • 1;1 • MY COMMISSION;rFF0556o5 • Personally Known OR =s• - . � [ sonally Known .� ..-0? ', EXPIRES September 1II.2017 [ ]Produced Identification "'••.FO EXPIRES September 18.2017 [ ]Produced Identific taonR; • Type of Identification: ow)39FS•OI53 FloridallolarySorvice.cort ��"pO3 t 53 FloridallotarySerncc com YP ,_...Type of Identification: - • DO NOT WRITE BELOW- OFFICE USE ONLY pp ca. e Coes: 2011 LIRISABU- DIN ODE Review Result (circle one): Approved Disapproved Approved'w/ Conditions Review Initials/Date: /'n� k.17• /7 Development Size • , Habitable Space 3 0 % SF'Non-Habitable /0/q S. Impervious area • Iiscellaneou.s Information )ccupancy Group IZ-3 ype of Construction V (3 'limber of Stories ming District /4/5 G G ax. Occupancy Load • -e Sprinklers Required • )od Zone X raditions/Coanmcnts: • OFFICE COPY R.O.W. Permit Attachment of for R.O.W. Permit# issued , 20 17 Atlantic Beach,FL 32233 Owner's Name: TOLL FL VI, LP Property Address: 1762 Atlantic Beach Drive Subdivision: Atlantic Beach Country Club R.E. #: 169505-1650 REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT, issued on this day of July , 20 177, by Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State of Florida, hereinafter referred to as "CITY"and TOLL FL VI,LP of Atlantic Beach, Florida, hereinafter referred to as "USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above (copies attached). This work is generally described as: Pavers in the Right of Way for the driveway. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30) days notice by CITY to the USER, said notice to USER shall be given by certified mail, return receipt requested, to the following address: 160 Cape May Avenue, Ponte Vedra, FL 32081 The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing, or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code,and all other land use and code requirements of the CITY, including City Code Section 19-7 (h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 OFFICE COPY The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall, at the discretion of the CITY, be requested to submit as-built drawings showing the change within thirty(30)days after the day of completion. This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. DATED and SIGNED •"s 2 day of July , 20 17 . By: Property 0 ifrIrSteven R. Merten, Division Sr. Vice President, TOLL FL VI,LP (to be signe. in presence of the Notary) STATE OF FLORIDA COUNTY OF ST.JOHNS On this 2-5 day of July , 20 17 , personally appeared before me, a Notary Public in and for said County and State, Sfeve 1l'1t i, Al✓ 5110 , the property owner of 11(,2 ,4-tlart+ic $tACArt- Dv. , Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instrument; who acknowledged to me that he or she executed the same freely and voluntarily and for the uses and purposes therein mentioned. 191111P' Notar, P •lic in for said County and State `Otp,11Y PV A °4;', MELISSA LIEBERMAN 1-frMY COMMISSION FF055605 tee: ':k.0„;�,,:' EXPIRES September 18.2017 (407);98-0t::,68-0153 FlorldehotaryService.com CITY OF ATLANTIC BEACH,FLORIDA, a municipal corporation: Approved: ‘Nli Scott i Tams 06/acv Interim Public Works Director File: 12/12/16 Page 2 of 2 Perini / P2E 17 - °I2" NOTICE OF COMMENCEMENT OFFICE COPY State of: FLORIDA Tax Folio No. 169505-1650 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 71 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E.155 Address of property being improved: 1762 ATLANTIC BEACH DRIVE,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 160 CAPE MAY AVE.,PONTE VEDRA,FL 32081 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): Name: Contractor: TOLL BROS.,INC. Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN,Division Sr.Vice President Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER ^� Signed: Date. ` V /2 Before me th. day of Ju/y, 20/7 in the Co ty of t.Johns, Doc#2017174533,OR BK 18065 Page 1710, State Of Flo ida,has personally appeared 9ffpe M-01-en, ,011/Si' Number Pages:1 Notary Public at Large,State • F orida,County of ST.JOHNS. Recorded 07/26/2017 at 02:33 PM, My commission expires '/,i/ Ronnie Fussell CLERK CIRCUIT COURT DUVAL Personally Known: ��% or COUNTY Produced Identification: �T RECORDING$10.00 ;;tippy =a A P��, MEL; Llci3cRrJIAiV I MY COMMISSION#FF055605 %:,Z4 of F e EXPIRES September 18.2017 t4071 393-0153 FioridallotaryServico.com OFFICE COPY Job: v. Project Summary Date: 1=;� �t, (Rest of House) By: Saldie Guintivano /tf -- -- McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com mail: smerten@tollbrothersinc.com Notes: The Anna Maria Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 37 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18631 Btuh Structure 18447 Btuh Ducts 2328 Btuh Ducts 3110 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20959 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21257 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2225 Btuh Ducts 527 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftl 1956 1956 Equipment latent load 3653 Btuh Volume(ft3) 19485 19485 Air changes/hour 0.26 0.14 Equipment total load 24910 Btuh Equiv.AVF(cfm) 84 45 Req.total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14N60300000A0 Cond CH14NB0300000A0 AHRI ref 9162305 Coil FB4CNP030L AHRI ref 9162305 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 20020 Btuh Heating output 28600 Btuh @ 47°F Latent cooling 8580 Btuh Temperature rise 30 °F Total cooling 28600 Btuh Actual air flow 875 cfm Actual air flow 875 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=27°F Backup: Input=6 kW, Output=20471 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Jun-07 16:30:42 W t IQht50fL' Comfort Builder by Wrightsofl 17.0.21 RSU03444 Page 1 ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE Project Summary Date: n_„ , e By: Saldie Guintivano iffaiNial" --.—_-- McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: 904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: The Anna Maria Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 37 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9454 Btuh Structure 10821 Btuh Ducts 1195 Btuh Ducts 1649 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) Humidification 0 Btuh Bloer 0 Btuh Piping 0 Btuh Equipment load 10649 Btuh Use manufacturer's data Y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2161 Btuh Ducts 288 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1120 1120 Equipment latent load 3049 Btuh Volume(ft3) 11727 11727 Air changes/hour 0.37 0.20 Equipment total load 15519 Btuh Equiv.AVF (cfm) 72 39 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0180000A0 Cond CH14NB0180000A0 AHRI ref 9162108 Coil FB4CNP018L AHRI ref 9162108 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17600 Btuh @ 47°F Latent cooling 5340 Btuh Temperature rise 31 °F Total cooling 17800 Btuh Actual air flow 525 cfm Actual air flow 525 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=22°F Backup: Input=3 kW, Output= 10649 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wr- htsoft- 2017-Jun-0716:30:42 Comfort Builder by Wrightso(t 17.0.21 RSU03444 Page 2 ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE + First Floor I i 12x 6, master 7- .. i dining 1 14x6 8" 12x6 14 2"4 12" s 10x6 great room 12x6 , • bath kitchen 12 x 6 7,. stairs/storage . sxa ' 10x6 8x4 4 4' 6" ." 10x6 (I32.. I 10" Sill •�wdr 12" 12x6 8x4 7" ..4" 10x6 5laundry wic study foyer J J ,8x2[I i,..., 4 1s• s. ox,o 16.. Els. . . 14 x 10 garage I Job#: McGowan's Heating & Air Condition... Scale: : 108 Performed by Saldie Guintivano for: Page 1 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.21 RSU03444 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2017-Jun-07 16:31:32 Phone:(904)217-0739 Fax:(904)814-8173 www.tollbrothers.com smerten©tollbrothersinc.corn www.mcgowansac.com Korey@mcgowansac.com ...The Anna Maria 3076 Right NE.rup Ak At ., Second Floor J '—� • 1 - J bath 2 8x4. 4"' 12x6 S 7" bed 2 bed3 ; 1 sink 4 x 8 la 4" 12x6 12x12 m!18x18 „ 10x6 7" 9" „ 14" 6" ♦ ,•• r1 r i 8x4.,. ■ 4" 12" wic 3 0. t l , attic bath 3 4 4 ' 10x 6 6„ stairs up 8 x 4 i12 4" • 12 x12 _ 9 _ [i 1.641 .0 12xx6 10x6 7" 0.. bed 4 open to below Job#: McGowan's Heating & Air Condition... Scale: 1 : 108 Performed by Saldie Guintivano for: Page 2 Steve Mertes 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 17.0.21 RSU03444 Ponce Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2017-Jun-07 16:31:33 Phone:(904)217-0739 Fax:(904)814-8173 www.tollbrothers.com smerten@tollbrothersinc.com www.mcgowansac.com Korey@mcgowansac.com ..The Anna Maria 3076 Right NE.rup Job: Manual S Compliance Report Date: (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.3°F Sensible gain: 21257 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.0°F Latent gain: 3653 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 24910 Btuh Indoor RH: 50% Estimated airflow: 875 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0300000A0+FB4CNP030L Actual airflow: 875 cfm Sensible capacity: 21273 Btuh 100%of load Latent capacity: 4016 Btuh 110Yo of load Total capacity: 25289 Btuh 102%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 33.5°F Heat loss: 20959 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0300000AO+FB4CNP030L Actual airflow: 875 cfm Output capacity: 22605 Btuh 108%of load Capacity balance: 27 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 875 cfm Output capacity: 6.0 kW 98%of load Temp. rise: 25 °F Meets are all requirements of ACCA Manual S. 2017-Jun-07 16:30:42 ." wrightsoft' Comfort Builder by Wrightsoft 17.0.21 RSU03444 Page 1 ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE Manual S Compliance Report Dae: 2nd fl By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.3°F Sensible gain: 12470 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.0°F Latent gain: 3049 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 15519 Btuh Indoor RH: 50% Estimated airflow: 525 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A0+FB4CNP018L Actual airflow: 525 cfm Sensible capacity: 12567 Btuh 101%of load Latent capacity: 3213 Btuh 105%of load Total capacity: 15779 Btuh 102%of load SHR: 80% Heating Equipment Design Conditions Outdoor design DB: 33.5°F Heat loss: 10649 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0180000A0+FB4CNP018L Actual airflow: 525 cfm Output capacity: 13927 Btuh 131%of load Capacity balance: 22 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 525 cfm Output capacity: 3.1 kW 100%of load Temp. rise: 38 °F Meets are all requirements of ACCA Manual S. 2017-Jun-07 16:30:42 wrightsoft' Comfort Builder by Wrightsoft 17.0.21 RSU03444 Page 2 ACrtk ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE Duct System Summary Dae: tvd� (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.297/0.093 in H2O 0.297/0.093 in H2O Lowest friction rate 0.104 in/100ft 0.104 in/100ft Actual air flow 875 cfm 875 cfm Total effective length(TEL) 375 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk dining h 3159 132 97 0.104 7.0 Ox 0 VIFx 65.2 220.0 st6 foyer h 2286 95 76 0.144 6.0 Ox 0 VIFx 35.6 170.0 st5 great room c 2444 50 99 0.144 7.0 Ox 0 VIFx 41.5 165.0 st4 great room-A c 2444 50 99 0.134 7.0 Ox 0 VIFx 52.2 170.0 st4 kitchen c 1838 65 75 0.110 7.0 Ox 0 VIFx 50.2 220.0 st6 laundry c 859 14 35 0.143 5.0 Ox 0 VIFx 38.0 170.0 st5 master c 4636 188 188 0.142 8.0 Ox 0 VIFx 39.6 170.0 st4 master bath h 2022 84 55 0.147 6.0 Ox 0 VIFx 37.0 165.0 st4 mwc c 98 1 4 0.141 4.0 Ox 0 VIFx 41.1 170.0 st4 pwdr c 60 2 2 0.147 4.0 Ox 0 VIFx 32.3 170.0 st5 stairs/storage c 55 0 2 0.150 4.0 Ox 0 VIFx 33.5 165.0 st5 study h 3010 126 103 0.109 7.0 Ox 0 VIFx 51.6 220.0 st6 wic h 1601 67 39 0.141 5.0 Ox 0 VIFx 45.0 165.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 323 274 0.104 592 10.0 0 x 0 VinIFIx st5 st4 Peak AVF 441 485 0.134 617 12.0 0 x 0 VinIFIx st3 st5 Peak AVF 434 390 0.104 553 12.0 0 x 0 VinIFIx st3 st3 Peak AVF 875 875 0.104 627 16.0 0 x 0 VinIFIx 2017-Jun-07 16:30:42 W rightsoft' Comfort Builder by Wr ghtsoft 17.0.21 RSU03444 Page 1 ACC .A ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 875 875 89.5 0.104 495 18.0 Ox 0 VIFx 2017-Jun-07 16:30:42 :,; wrightsoft' Comfort Builder by Wrighlsoft 17.0.21 RSU03444 Page 2 /4C�"t.A. ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE Duct System Summary oa e : E=='Awowyea 2nd fl By: SaldieGuintivano ��.,_ . McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road.Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904) 217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.235/0.155 in H2O 0.235/0.155 in H2O Lowest friction rate 0.151 in/100ft 0.151 in/100ft Actual air flow 525 cfm 525 cfm Total effective length(TEL) 259 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk bath 2 h 378 19 16 0.154 4.0 Ox 0 VIFx 28.0 125.0 st1 bath 3 h 555 27 24 0.195 4.0 Ox 0 VIFx 10.5 110.0 st2 bed 2 c 2390 88 101 0.157 7.0 Ox 0 VIFx 24.5 125.0 st1 bed 3 c 2694 102 113 0.191 7.0 Ox 0 VIFx 8.2 115.0 st2 bed 4 c 2493 96 105 0.180 7.0 Ox 0 VIFx 15.6 115.0 st2 loft c 1246 50 52 0.164 6.0 Ox 0 VIFx 18.6 125.0 st1 open to below h 1379 68 58 0.151 6.0 Ox 0 VIFx 31.2 125.0 st1 sink c 70 2 3 0.159 4.0 Ox 0 VIFx 23.2 125.0 st1 stairs up h 1084 53 38 0.156 6.0 Ox 0 VIFx 26.1 125.0 st1 wic 2 c 104 3 4 0.178 4.0 Ox 0 VIFx 12.4 120.0 st2 wic 3 h 310 15 10 0.194 4.0 Ox 0 VIFx 6.4 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 281 268 0.151 358 12.0 0 x 0 VinIFIx st2 Peak AVF 244 257 0.178 471 10.0 0 x 0 VinIFIx 1 2017-Jun-07 16:30:42 �^t`K� wrightsoft' Comfort Builder by Wrightsoft 17.0.21 RSU03444 Page 3 Y11it+11 ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE 1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb12 Ox 0 121 96 101.8 0.152 275 9.0 Ox 0 VIFx ill rb13 Ox 0 127 134 102.7 0.151 302 9.0 Ox 0 VIFx rt1 rb3 Ox 0 141 156 87.0 0.178 146 14.0 Ox 0 VIFx rt1 rb11 Ox 0 136 139 87.5 0.177 315 9.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 525 525 0.151 491 14.0 0 x 0 VinIFIx 11 I 4! 11 r !�^� wri htsoft' 2017-Jun-0716:30:42 /94L+� Brothers 9 Comfort Builder by Wrightsoft 17.0.21 RSU03444 Page 4 p ...\Toll Brothers\The Anna Maria 3076 Right NE.rup Calc=MJ8 Front Door faces:NE I Static Pressure and Friction Rate Job: Date: (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0.06 0.0E Heat exchanger 0 0 Supply diffusers 0.02 0.02 Return grilles 0.03 0.02 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.39 0.39 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 19 15 Measured length of trunk 46 0 Equivalent length of fittings 220 75 Total length 285 90 Total effective length 375 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.104 OK 0.104 OK Return Ducts 0.104 OK 0.104 OK Fitting Equivalent Length Details Supply 11C=40,4X=35, 11G=5, 11C=40, 11G=5, 11G=5, 11C=40, 11G=5, 1A=35, 11G=5, 11G=5:TotalEL=220 Return 5E1=10,6M=20, 11C=40, 11G=5:TotalEL=75 2017-Jun-07 16:30:42 �4C41- wrightsoft° Comfort Builder by Wrightsoft 17.0.21 RSU03444 Page 1 ...\Toll Brothers\The Anna Mana 3076 Right NE.rup Calc=MJ8 Front Door faces:NE Static Pressure and Friction Rate Job: Byte: r . iii.. G�� ....�«v.....« 2nd fl By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park.Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:Korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0.06 0.0E Heat exchanger 0 0 Supply diffusers 0.02 0.02 Return grilles 0.03 0.02 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.39 0.39 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 16 9 Measured length of trunk 15 9 Equivalent length of fittings 125 85 Total length 156 103 Total effective length 259 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.151 OK 0.151 OK Return Ducts 0.151 OK 0.151 OK Fitting Equivalent Length Details Supply 4X=35, 11C=40, 11G=5, 1A=35, 11G=5, 11G=5:TotalEL=125 Return 6M=20, 11C=40, 11G=5, 11G=5, 5E1=10, 11G=5:TotalEL=85 2017-Jun-07 16:30:42 :;„ wrightsoft Comfort Builder by Wrightsoft 17.0.21 RSU03444 Page 2 ACLA ...\Toll Brothers\The Anna Maria 3076 Right NE.nip Calc=MJ8 Front Door faces:NE -- OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Anna Maria 3076 Right NE Builder Name: Toll Brothers,Inc. Street: Lot 71 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3293.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 3073.30 ft2 b.Frame-Wood,Adjacent R=13.0 220.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4d.N/A R= ft2 10.Ceiling Types (1956.0 sqft.) Insulation Area 5. Is this.a worst case? No a.Under Attic(Vented) R=38.0 1736.00 ft2 6. Conditioned floor area above grade(ft2) 3076 b.Under Attic(Vented) RR=19.0 220.00 ft2 2 Conditioned floor area below grade(ft2) 0 c.N/A 11.Ducts R • 7. Windows(489.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 288 a. U-Factor: Dbl,U=0.33 489.25 ft2 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 188 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 30.0 SEER:14.00 • SHGC: b.Central Unit 18.0 SEER:14.00 c. U-Factor: N/A ft2 •. SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A .ft2 a.Electric Heat Pump 30.0 HSPF:8.20 SHGC: ' b.Electric Heat Pump 18.0 HSPF:8.20 : Area Weighted Average Overhang Depth: 3.641 ft. . Area Weighted Average SHGC: 0.300 14.Hot water systems a.Natural Gas Tankless Cap:1 gallons 8. FloorTypes (3076.0 sqft.) Insulation Area .EF:0.800 a.Slab-On-Grade.Edge Insulation R=0.0 1956.00 ft2 b. Conservation features ' b.Floor Over Other Space R=0.0 1120.00 ft2 None c. N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 69.57 :PASS Glass/Floor Area: 0.159 Total Baseline Loads: 81.16 ' I hereby certify that the plans and specifications covered by Review of the plans and ;r•``Q." E.$ A.TS'.,,. this calculation are in compliance with the Florida Energy - specifications covered by this ` N.,..�. CI' F ::0.2�';. Code. calculation indicates compliance ��„ . / with the Florida Energy Code. �ti ow. "4, %.-•,.'',•°.• ,i`•O'n'' PREPARED BY: /%--,�. . ., - .•_ -P Before construction is completed ' DATE: 06-D,Y-2-0/;z this building will be inspected for 'V f compliance with Section 553.908 ,. 1-: I hereby certify that this building,as designed,is in compliance Florida Statutes. 1,:f.�,/... 110- .:�` ..05'�4. with the Florida Energy Code. 47 0t,N ''` 0 OWNER/AGENT: Brianna Tallman BUILDING OFFICIAL: fil DATE: 7-25-2017 DATE: ( it •i 7 q? - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. • 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I I FORM R405-2014 PROJECT Title: Anna Maria 3076 Right NE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3076 Lot# Owner: Toll Brothers,Inc. Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers,inc. Rotate Angle: 0 Street: Lot 71 Atlantic Beach C Permit Office: Atlantic Beach Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS • • Number Name Area Volume • 1 Biockl 1956 19560 2 Block2 1120 10080 . SPACES • • • Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated • 1 Main 1956 19560 Yes 2 1 1 Yes Yes Yes ' • 2 2nd Floor 1120 10080 No 3 3 1 Yes Yes Yes • • =FLOORS • V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 161 ft 0 1956 ft2 ____ 0 0 1 • 2 Floor Over Other Space 2nd Floor __ ___ 1120 ft2 0 0 0 1 • ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) • 1 Gable or shed Composition shingles 2188 ft2 490 ft2 Medium 0.6 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC li - 1 Full attic Vented 300 1956 ft2 N N • 111 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 t I FORM R405-2014 CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) . Main 38 Blown 769 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 38 Blown 967 ft2 0.11 Wood ' 3 Under Attic(Vented) Main 19 Blown 67 ft2 0.11 Wood 4 Under Attic(Vented) 2nd Floor 19 Blown 153 ft2 0.11 Wood WALLS `/ Adjacent Space Cavity Width Height Sheathing Framing Solar Below V it Ornt To WalL2.ypP R-Vahic Ft In Ft In Area R-ValoP Exaction Absor Grads.% _ 1 NE Exterior Frame-Wood Main 19 23 0 10 0 230.0 ft2 0 0.23 0.6 0 2 NE Exterior Frame-Wood 2nd Floor 19 34 0 9 0 306.0 ft2 0 0.23 0.6 0 •_ 3 SE Exterior Frame-Wood Main 19 50 8 10 0 506.7 ft2 0 0.23 0.6 0 _4 SE Exterior Frame-Wood 2nd Floor 19 42 8 9 0 384.0 ft2 0 0.23 0.6 0 5 SW Exterior Frame-Wood Main 19 45 0 10 0 450.0 ft2 0 0.23 0.6 0 6 SW Exterior Frame-Wood 2nd Floor 19 34 0 9 0 306.0 ft2 0 0.23 0.6 0 7 NW Exterior Frame-Wood Main 19 50 8 10 0 506.7 ft2 0 0.23 0.6 0 8 NW Exterior Frame-Wood .2nd Floor 19 42 8 9 0 384.0 ft2 0 0.23 0.6 0 • 9 NE Garage Frame-Wood Main 13 22 0 10 0 220.0 ft2 0 0.23 0.01 0 . DOORS 4 Ornt Door Type Space Storms U-Value Ft Width In FtWidthArea . 1 NE Insulated Main None .3 3 8 24 ft2 .2 NE Wood Main None .39 .2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. • Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Area .Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.33 0.3 12.9 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 • .2 NE 1 Vinyl Low-E Double Yes 0.33 0.3 36.0 ft2 8 ft 0 in 1 ft 0 in None Exterior 5 3 NE 2 Vinyl Low-E Double Yes 0.33 0.3 24.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 4 NE .2 Vinyl Low-E Double Yes 0.33 0.3 31.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 5 NE 2 Vinyl Low-E Double Yes 0.33 0.3 8.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 6 SE 3 Vinyl Low-E Double Yes 0.33 0.3 31.0 ft2 1 ft 4 in '1 ft 0 in None Exterior 5 - 7 SE 4 Vinyl Low-E Double Yes 0.33 0.3 24.1 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 8 SW 5 Vinyl Low-E Double Yes 0.33 0.3 46.5 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 9 SW 5 Vinyl Low-E Double Yes 0.33 0.3 31.0 ft2 8 ft 4 in 1 ft 0 in None Exterior 5 10 SW 5 Vinyl Low-E Double Yes 0.33 0.3 96.0 ft2 8 ft 4 in 1 ft 0 in None Exterior 5 11 SW 6 Vinyl Low-E Double Yes 0.33 0.3 62.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 12 SW 6 Vinyl Low-E Double Yes 0.33 0.3 4.5 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 13 NW 7 Vinyl Low-E Double Yes 0.33 0.3 24.1 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 14 NW 8 Vinyl Low-E Double Yes 0.33 0.3 12.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 15 SE 3 Vinyl Low-E Double Yes 0.33 0.3 24.1 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 16 SE 4 Vinyl Low-E Double Yes 0.33 0.3 6.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 17 NW 7 Vinyl Low-E Double Yes 0.33 0.3 16.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 GARAGE ._ V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 640 ft2 640 ft2 73 ft 10 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000306 2470 135.6 255.02 .2902 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 30 kBtu/hr 1 sys#1 2 Electric Heat Pump Split HSPF:8.2 18 kBtu/hr 2 sys#2 COOLING SYSTEM •V # System-Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:14 30 kBtu/hr 900 cfm 0.7. 1 sys#1 . 2 Central Unit Split SEER: 14 18 kBtu/hr 540 cfm 0.7 2 sys#2 . HOT WATER SYSTEM •# System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg None • SOLAR HOT WATER SYSTEM • V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF • None None .ft2 DUCTS • • V --Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 288 ft2 Attic 67 ft2 Default Leakage Garage (Default) (Default) .1 1 •. 2 Attic 6 188 ft2 Attic 76.9 ft2 Default Leakage 2nd Floor (Default) (Default) 2 2 ( 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I 1 FORM R405-2014 TEMPERATURES Program able Thermostat:Y Ceiling Fans: Cooling HJJaann [[ ]]Feb [[ Mar [ ]A r nt ritus riEeer) ( )Oct ]Nov DecHeating [X)Feb [X�Mar []Apr Eirg � [ )Oct [X]Nov XDec Venting Jan [[ ])Feb [[X Mar [X]Apr May Jun Jul Aug Sep [XJ Oct [X)Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 66 • Heating(WEH) AM 66 68 68 68 66 68 68 68 68 68 68 8 68 68 66 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 • FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 86 The lower the EnergyPerformance Index, the more efficient the home. Lot 71 Atlantic Beach CC, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 3073.30 ft' 2. Single family or multiple family Single-family b.Frame-Wood;Adjacent R=13.0 220.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1736.00 ft2 • 6. Conditioned floor area(ft2) 3076 b.Under Attic(Vented) R=19.0 220.00 ft2 c.N/A R= ft2 7. Windows** Description Area a. U-Factor: Dbl,U=0.33 489.25 ft2 11.Ducts R ft a.Sup:Attic,Ret:Attic,AH:Garage 6 288 SHGC: SHGC=0.30 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 188 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A .ft2 a.Central Unit 30.0 SEER:14.00 SHGC: b.Central Unit 18.0 SEER:14.00 d. U-Factor: N/A • ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 30.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.641 ft. b.Electric Heat Pump 18.0 HSPF:8.20 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area - 14.Hot water systems a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1956.00 ft2EF:0.8 b.Floor Over Other Space R=0.0 1120.00 ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building .,." IHE Sat'• , Construction through the above energysavingfeatures which will be installed (or exceeded) 46' 9 ,` o' in this home before final inspection. Otherwise, a new EPL Display Card will be completed ..4; '4'1-:. ... , '� e(.''4 .',% �BOE based on installed Codi orapliant featur .. // l„r �`ar�.•';:,� Builder Signature: , 11 i, `I v A V /ill ii Date: 7-25-17 o ��iiy �;�.�' �y Cit /FL Zip: 4. At.y • Address of New Home: 1762 Atlantic Beach Drive YAtlantic Beach, 1.* --....`.. �5` ..• •' FL, 32233 - *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 • FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Lot 71 Atlantic Beach CC Permit Number: Atlantic Beach,FL, MANDATORY REQUIREMENTS See individual code sections for full details. O 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. O R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections 8402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. • Where required by the code official,an approved third party shall inspect all components and verify compliance. -• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup alr,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systemsand heat recovery ventilators shall be closed and sealed; • 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. • O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the Interior wall or ceiling covering. O R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. O R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. •0 R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be'substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 Inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 -Section 8405.4.1 Com Page 1 of 3 11111 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have • heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water Ilne located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment Installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is Installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. • O R403.6.1.2 Heating equipment capacity ▪ R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6:1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6;1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. O R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature Is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum ▪ thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9:1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: ' 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. 0 RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights - 0 R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 i FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Anna Maria 3076 Right NE Builder Name: Toll Brothers,Inc. Street: Lot 71 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. ✓ The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. ✓ Exposed earth in unvented crawl spaces shall be covered with a Class vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air ✓f barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Anna Maria 3076 Right NE Builder Name: Toll Brothers,Inc. Street: Lot 71 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number. Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 3076 sq.ft. Cond.Volume: 29640 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): • Single or Multi Point Test Data HOUSE PRESSURE I FLOW: I ELA: EqLA: ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, ,.-.'a�T1:1E Sr�Z�.,.; performance results demonstrate compliance testing shall be conducted by an with Florida Energy Code requirements in approved third party. A written s e accordance with Section R402.4.1.2. report of the results of the test shall _ ... _ be signed by the third party •• • - . • conducting the test and provided to SIGNATURE: the code official. . j . '` YY4`if X15-~. PRINTED NAME: .""•.. BUILDING OFFICIAL: DATE: DATE: 6/7/2017 5:20 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 a- 0 U 4t W v U_ a M L N O %p N 0o d m:; in . ) .... �°'. Noo o w Y k" a M " LI d Q 00 N _ ut d N _ 0 y e et N ,� en ct O in %D 0 00 Q t+ X. •--- "• N •--- .--i vl N — O Ainwww w w w w w d E N c d w I C o � a x ej N >} a o 0 0 0 aW ti 0, 0 w .a U 0 0csi o B tel in kel co 0 0 0r W H w < o 0 0 0 Q oa N +Z ya. � S Z Z + + + Z + -• E II d " c b ceoa C a. o4 c›"I °w0 3 o 5 Ac b � i , 0 ,-. Ra -v O c -0 V .. (1) 0y p 0 ' C3 33c n O b •E W Al ` as vs 6. S 'eh' y Eo E-1o " a w 50 x 0 x a a -, a• -a w o c n x u > 7 poO •-i r-- 0 • o 0 16 E >, a, >, L y c c c 4 ct, a 0 00 aw o w a 0 >... ON g Z M a) 0 C°w H N s:4 al 0 M w ; a c ii z co v, O L].. o L• V' y aics g E U •O r a p 'a 0 "., os c). P. i = o 04 3 3 , e b mi ood A t : 0 0 .l4 3 H V O 0p c C y a) O •n ,n VI N U � c E._, F. - (-I E�CO N 9 O a EPo Ad . co y 0 fn O. 0 C. G L. a. O Y ' S o ° 'a oa aoi > 0 a E� o > aaDi 0 •s.. o , A °' at... O v a :d c ai ': Z w ai = O 00 v, 004 °' v b ° 2 8 ° o �" 0 X 0 aoi ami oA. c _ o a1 o a) 3 •b on W on c a d o c 11 �' rn 41 4. �, 2 O ��, H C". O E i. A .17.: N yv} .L) b v .� fl a) v� Q. p cr v at X •5 • o .� O N .-• = O R O •x 2 O '� O a U W �3 •in v� ap' QO •v� ]CUAw < A. 4 3 � 0 - Q W •--; N M 4 to kOco "" N re) v)• •�O o• o •O\ „r E •t i d U 0 J V -- cV o0 C as — o en N o — — CG 7) l`.1 M — .r — C 1 — — ci o7 ,n o7 00 't r- r7 't [� C C ,. C O r 1 --r — .... O CD • N o o — r r` rr) N S M N O o7 -r N M N ,_ — (� — — — — — — 'n — oo ._a —) J ,_J J _..) -2. __) Lc.. t_1_, — (- Ix.. c:. 1i LL, .. .... U 0 C 0 MI o M G < _Q _Q Q __ Q Q < - i .r 7. Z Z Z en Z Z Z 7. 7 C ti o en .Q U U a. (n J U v) 4 /) 1 U QU ) iPa 3 7f) a < U (/) U a L " - 2 *J 'D a o L. a o a 7n U 1 Ll erjti ti J' en ... on u 70 U) U f U 7Ct:1 j = c c r 0 - n N• _a c«. — 1 C3 cC 0 0 - U .--) J V) (n - H w -. ! % U U a vi v' U U 0 • - L o 2 O 0 �- — J V 7n or) a r-; a a a N _ c:_. 'a -c U :i� — L •... •7-,' I n c73 "..--- 2 U L C3 C C a ° -d ° C7 a n o = ft U CI U L a o = s v CI Z s U U0 m - U U U s > Cc O v 1 n E U E o ¢ ° r O ztiz :.e L73OD • z U t4 cn H w ooio U 0 .) a) a CS In co U . OLU U >, .0 .1 O a V) .O a OU > O on yc o n U cG ° Y o aca 7, yU o em « U y -7 O a) . U U v, -7 ....E. a .O G ° c — Cm a o ° a 0 U ti CZ4aL >, O . „ aA cc o O " U . an o 0 -10 _ svZc c v w4-. yaco Q ° o ' T.:11 ) e-. 0 ' ' �' r U d oo r'- o L c o Ec0 33 ° ° ° Q. n n w iU 3 2 VO Q Zw >7 n oG a UavO j( - cNi en v v � r; oo c' o [ — CI o ri � vi oo el 0 4t Ti v 0 a 4t ti.) to coc c V • Y C C C •b1) N) c`,1 7 _.. c3 _ C C O �t U CCS — `L U N N a cl 0 V) 4. 0.... 4-. O O o -b C 0 U c3 O tv.= c3 ti ) U 0 U U . 00 a .... 3 0 ami C L U V Y •a C L to to0 .. C 4' 1) W L C L Qel E- } 0 Q C L I. CCS v, L > N 0, v N ,_ OL ..c D J 0. CCS :s P >. i... N U ✓; G, - 1 4.. 'C ,_l to ./ v O e- V - W LLOv C U cc C r O bf) i v 0 c) 0 L a) 0 O IL O dO NO C 0 j- 'L _ C tf) t '.1 > Cn U f) 0 cd c'i o n t as C a W G 1 c' O t? C o y N ,Y„ ,_ a. Oa co -.' \... U 0 U I— V: Ci VJ t� >O •—, C L C G. oN O c H U to c J C y O U C . u as ro .. p --a -Fs 3 v, cn N C4 H ° N x E H W a.., 0 - c U O I. W e c C E W e °' v L cau -Ci a x X W o N is O E" Ca U Z ``e CO. _ o o C7 ^ W p. c L a r- '"0 G C = Q. L �--i O ,� S7. y to L .� • U L N L. O O O 0 LO ►.., Vn C C N V Y a . yC — D O } b� s 3 ► Y U U `li v CI $ 0 o Cr F, o on - o C cs y ) C, > .0 t % s W W �a V) Q Cr) cn U W O v1 F W C4 U U c a. m 3 cn O cn ,....NA O Z . c W N M �n N W U N M 4 vi N 00 O _ Ni c2 V - N x W -- N c U .G tn a) 0 / 17111 c f1141 , tv ) 0 . E o a \ 0 a, n 7 -0 , \ 2 > o a) V j \ '')-4•••.. 5 \ § 7 a g iii g 2 t S L. � .. { t / —0 TS§ : hi Z $ a J \ 7 oE 0 00 .03 ƒ g 2 0 § ./ § / / R / § q/\ \ -. b , * E E § ® % $ 0 u z ) 2 $ & f ) as - § \ E c c ƒ U ® / — o .1- co 4 / { g \ £ e ? 0 ( H 0 > b § k § 0 E ` 7 ƒ k k ) 0 z - z - f / ƒ _ Q. \ -,• - U 0 \ G / U /., ,-S�\'� City of Atlantic Beach APPLICATION NUMBER /� ,:; Building Department (To be assigned by the Building Department.) 800 Seminole Road y j� Es 7 _G ( z _r Atlantic Beach, Florida 32233-5445 %tlq� 1`� Phone(904)247-5826 - Fax(904) 247-5845 r•T,1119%-- E-mail: building-dept@coab.us Date routed: ie2/4ft 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 17CQ7_ f -/Qn e, 3icJ- Department review required Yes No ��" ( (f di t Applicant: o I ("-- rosr., ___.-rining &ET Tr' ee Administra�for Project: 1\)GAD S 1!1 l(:) EOM ( l lc Works ) c iiles1 Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By _ Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District ~ Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco _ Other: APPLICATION STATUS Reviewing Department First Review: 1[�Approved. I !Denied. ['Not applicable (Circle one.) Comments: s'�� a#0Go-I a BUILDING PLANNING & ZONING Reviewed by: 42_ Date: .�--,4." TREE ADMIN. Second Review: HApproved as revised. ❑Denied. f Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 OI.Any City of Atlantic Beach APPLICATION NUMBER el :`'£4 Building Department rIsceivE (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 k' RE-,S -7! U Phone(904)247-5826• Fax(904)2 7,58AUG l 2017Q �o� �? E-mail: building-dept@coab.us r Date routed: 47 City web-site: http://www.coab.us r APPLICATION REVIEW AND TRACKING FORM Property Address: 7'Z B.f.\ Department review required Yes No Applicant: l O l ( CS 1-b .'C..jsnmg &Zonm .) Tree Administrator Project: i\-) -C-4/0 S l n ' p EQ M r•• lc Works j •ublic sgreir Fire Services Review fee $ 5-0 Dept Signature C. v"— Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPL ATION STATUS Reviewing Department First Review: Approved. ❑Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING y..l //eP4 .? Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. ❑ pP ❑Denied. ❑Not applicable IC WOR Comments: P BIC UTILITIES 1iO—// PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 fiEsolS�`�'�1'i�;, City of Atlantic Beach �f PUBLIC UTILITIES DEPARTMENT r s) 1200 Sandpiper Lane T5 J ��r J,il>! Atlantic Beach, FL 32233 (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date 8- 10 -11 Project Address ( 7 Co Z AT(A'N c t c ‘ e Dr- Number of Units I Commercial Residential Multi-Family 3 '' New Water Tap(s) & Meter(s) Meter Size(s) q New Irrigation Meter Vi Upgrade Existing Meter from to (size) / 31q ,/ New Reclaim Water Meter t Size New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature I CITY STAFF USE ONLY Application # l?t S 11 a 2 2 Water System Development Charge $ I , I LI 0 1 00 Sewer System Development Charge $4 t 0 50 t 06 Water Meter Only $ I ss- vv Reclaim Meter Only $ I , Ov Water Meter Tap $ Sewer Tap $ Cross Connection $ SO, vv Other $ TOTAL $ S, Co r 0 , DO (Notes) APPROVED Kayle Moore, P.E. '� 1(.'"(' \ Date 7 Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED '�/ Ii .a.._ 'CITY OF ATLANTIC BEACH ,� 9 i( 800 Seminole Road ,0• li...• l'i "S� Atlantic Beach,Florida 32233 '� �" I' •d Telephone(904)247-5800 . -:4 AUG 1 4 2017 ._ FAX(904)247-5845 1 aril Jr nN_ROt1EST STREET OR CORRECTIONS TO REVIEW COMMENT Date: 8/14/2017 Received by: Resubmitted: Permit Number: 12-es "0 l Original Plans Examiner: Project Name: Lot 71 Project Address: 1762 Atlantic Beach Drive Contractor: Toll Bros., Inc. Contact Name: Brianna Tallman Contact Phone : 904-595-5243 Contact e-mail: btallmantu'�.tollbrothers.com Revision/Plan Check/Permit Fee(s)Due: $ Description of Proposed Revision to Existing Permit: Dverellheight_is..now._shown_on_the front.e1evationalouded and tagged on sheet A5.82. Additional Increase in Building Value: $ Additional S.F. Site Plan Revised: Public W/U Approval: By signing below.I (print mune)' Y'\ \r O. ---rec1 I m(xY) affirm that the above revision is inclusive of the proposed ch ges. 1&444 ?- 1'1G�/\ * l i G��I Signature of Contractor/Agent(Contraclor must sign if increase in valuation) Date Office Use Only Date: Approved: / _ Rejected: Notified by:.__ — Plan Review Comments: •pment review required Yes No . --,---- : .•Idine -.. • < nine &Zoning Tree Administrator Plans Examiner Public Works ?// S/ Z O/—2 Public Utilities _ Public Safety Date (lceied 4'1 In Iter 3 Fire Services TOLLARCHITECTURE MEMO TO: Stacia Moore Atlantic Beach Heritage 160 Cape May Avenue Ponte Verda, Florida 32081 CC: Brianna Tallman FROM: Manuel Gonzalez, AIA Toll Brothers, Inc. DATE: August 10, 2017 RE: Atlantic Beach Heritage—Lot 0071 —Anna Maria/ Coastal—AO#154777 Rejection Comments On the above referenced lot, this letter shall be used to revise or clarify the following condition(s): Permit Comment: Height: Section 24-17 requires height to be measured from grade to the highest point of a building's roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans. Toll Architecture Response: The overall height has been shown on the front elevation; clouded and tagged on sheet A5.82. Please feel free to contact this office if there are any questions regarding this matter. Sincerely, Ili OF FC.,s r�P .IAS •00°°°0- 00 4 / o • • • a AR9•• 0 0 �j 0 �C`� °,`moi �,T°0000 _ �� 14111111 10. Manuel Gonzalez,AIA AR 96730 ZONING REVIEW COMMENTS 1Si City of Atlantic Beach �° } Community Development Department 800 Seminole Road Atlantic Beach,Florida 32233-5445 on319 Date: 8/9/2017 Permit: RES 17-0128 Applicant: Toll Brothers Review: ZONING Address: 160 Cape May Ave, Ponte Vedra, FL Site Address: 1762 ATLANTIC Phone: 217-3852 BEACH DR RE#: 169505 1650 Email: btallman@tollbrothers.com Correction Comments Height: Section 24-17 requires height to be measured from grade to the highest point of a building's roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans. Informational Comments Brian Broedell Planner CA City of Atlantic Beach APPLICATION NUMBER Building Department`� 800 Seminole RoadTo be assigned by the Building Department.) :_) c-_s t 7 -U t ZAtlantic Beach, Florida 32233 5445Phone(904)247-5826 • Fax(904)247-5845 9P E-mail: building-dept@coab.us Date routed: 5/4 l City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 7CQ2. PV+IQJ 1C jc Department review required Yes No mac) L ( c� 9 Applicant: �-- �' nm &Zornn Tree A minis ra ory Project: Cts Si ' EOcv\ ti is Works? c i i les Public Safi Fire Services Review fee $ Dept Signature , Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. enied. ❑Not applicable (Circle one.) Comments: 4,a(� / 1 l BUILDING / !� l 7 �� Q�e PLANNING &ZONING Reviewed by: / Date —Cl I TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. ONot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ElApproved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ZONING REVIEW COMMENTS City of Atlantic Beach » r Community Development Department '� 800 Seminole Road Atlantic Beach,Florida 32233-5445 Date: 8/9/2017 Permit: RES 17-0128 Applicant: Toll Brothers Review: ZONING Address: 160 Cape May Ave, Ponte Vedra, FL Site Address: 1762 ATLANTIC Phone: 217-3852 BEACH DR RE#: 169505 1650 Email: btallman@tollbrothers.com Correction Comments Height: Section 24-17 requires height to be measured from grade to the highest point of a building's roof structure or parapet and any attachments thereto, exclusive of chimneys. Please show the overall height from grade on plans. Informational Comments Brian Broedell Planner NOTICE OF COMMENCEMENT State of: FLORIDA Tax Folio No. 169505-1650 County of: DUVAL To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: Lot 71 Atlantic Beach Country Club Unit 2,67-132 08-2S-29E.155 Address of property being improved: 1762 ATLANTIC BEACH DRIVE,ATLANTIC BEACH,FL 32233 General description of improvements: NEW HOME CONSTRUCTION Owner:TOLL FL VI LIMITED PARTNERSHIP Address: 160 CAPE MAY AVE.,PONTE VEDRA,FL 32081 Owner's interest in site of the improvement: FEE SIMPLE Fee Simple Titleholder(if other than owner): itt.5,f Contractor: TOLL BROS.,INC. Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: STEVE MERTEN,Division Sr.Vice President Address: 160 CAPE MAY AVE.PONTE VEDRA,FL 32081 Telephone No: 904-217-3852 Fax No: 904-460-2683 In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): CD THIS SPACE FOR RECORDER'S USE ONLY OWNER n Signed: Date'Co7 3 e/ Before me tit' day of July, 20/7 in the ty of t.Johns, Doc#2017174533,OR BK 18065 Page 1710, State Of Flo da,has personally appeared Stege"0,14,),/1/V so' Number Pages:1 Notary Pub tc at Large,State • F •rids,County of ST.JOHNS. Recorded 07/26/2017 at 02:33 PM, My commission expires;/'/,,/ s Ronnie Fussell CLERK CIRCUIT COURT DUVAL Personally Known: V or COUNTY Produced Identification: RECORDING$10.00 /'`'' MELI LIEBERMAN 1:4 MY COMMISSION#FF055605 EXPIRES September 18.2017 (40-4 3k, 3 FloridallolaryServace.com