Loading...
2031 Beach Ave flat roof permit A N CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-SS14 PERMIT INFORMATION: PERMIT NO: ROOF17-0035 Description: replace flat roof Estimated Value: 11700 Issue Date: 9/27/2017 Expiration Date: 3/26/2018 PROPERTY ADDRESS: Address: 2031 BEACH AVE RE Number: 1697100000 PROPERTY OWNER: Name: WINDSOR H BISSELL LIVING TRUST Address: 2031 BEACH AVE ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: Sunbelt Homes and Roofing LLC Address: 450 SR 13 N Suite 106 Pmb 409 ST JACKSONVILLE, FL 32259 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road (Z,00 F 1 0 0,�I Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904)247-5845 E-mail: building-dept@coab.us Date routed� City web-site: http://vmw.coab.us I APPLICATION REVIEW AND TRACKING FORM Property Address: DepanTent review required Y No 'Building — _�) 7 Applicant: SLL()Wk 60-11ks anning oning Tree Administrator Project: �L4L-� f Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Siqnature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental P�rotection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [qA' pproved. []Denied. E]Not applicable (Circle one.) Comments: (:E D PLANNING &ZONING Reviewed by:_ Date: Of TREE ADMIN. Second Review: F]Approved as revised. F]Denied(/ [—]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ElApproved as revised. E]Denied. E]Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application Updated 515117---- City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 SEP 2 6 2017 Phone: (904) 247-5826 Fax: (904) 247-5845 JobAddress: /3,-4e_� 6i/ <_ PermitNumber: 90pFl-t— co3S— I . 0 '9 7,0 -v _V)z) Legal Description S -(33 0 SI -a-5 -49 IF 4) ktlsw+,L�il(c,(-L L)&)JAQ 3,rf'"RE " " Valuation of Work(Replacement Cost)$ Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • if an existing structure, is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: I­ Rc�0 0 1, /�c 0 N4 t I R t aluo Kyat- J _ Florida Product Approval# '-I t &75or 'i--/ for mu tiple products use product app'ro'val form Property Owner Information Name: L) 8 ;ssc /I Aciclress:_��l dr_�LL W- City A±JA MJ 'L &eal C.1 State t-I Zip -137) Phone Qq qT)3 E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information _L,C, Qualifying Agent: �3 Name of Company:_.�t.,V124 JIJGM(� 441,1 �&r4*,V4 Address 13 city J-7, T�,hs- State zip 3 22--f't Office Phone 70 i� JobSitgContact Number - 7 0 State Certification/Registration# JAT, I'-);L7 I _LLP 0_)4 J/ -Tofn ;XA6-4c?411� Architect Name& Phone# Engineer's Name& Phone# Workers Compensation Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECOR"GY URN T!�� OF COMMENCEMENT. (�,ignatu reof 0-wn'e'r or Agent) (Signature of Contractor) (including contractor) S' d _�ko i m e r?,,rkt i e thJ day of Ipe a _Ln,Lo Lo r a igned an swj��or affirmed) before m �JL �V Ob M — - I--, -4 Q_A1WW v, EL PAMELA Jf ,,,��JE24 SHORE A ol Flo lic A N a au Notary Pub �rMPLPS04AT My Comm.Expivres Dec(Bjg�?W of Notary) 0 CommZ1 n #IFIF 074537 Commission # FF 074537 Personally Known OR Personally Known OR Produced Identificati Produced Identification "s a go Type of Identification: Type of Identification: 1 01 Ii�elrlrmk -_jtf7_ POO F t 7 - c c, 3 57 OFFICE COPY NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE) Permit No.�Foo rl-2 — nc) 5y TaxFolioNo. State of 11 ! C To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated In this NOTICE OF COMMENCEMENT. Legal descrif tion of propprty being improved: 14 ItV4.,C -70 L14 Address of property bein irnprovv: 114, A General description of improvements: Owner A.)i tl Address A+4 0"t, _?q Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor L,A.) AA4 Z ,�_)�C4, Address E�Qj 11 '1);&40�7 � Phone No. _70;-2 Fax No. urety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY E 11;�Z�/IAT1 — — — — — — — Before me this dt LX A__z C Tr ppeared herein by PA7MELA JEAN SHORE hiffself/hefWfand affirms that all statements and cleclarations herein Pu lie Sta 0 1 Tr.. , are true and accurate Notary Public-State of Florida nm xpir s My Comm.Expires Dec 4,2017 ,P Z ,ff, We C mi, 1..0 rl:n A I ommission#FF 074537 Doc#2017219Q2,OR 13K 18128 Page 1781, 111c1ary Public at Large- ty0f IpWi U Number Pages 1 myoommisslonexpireeffxu��C,01 Recorded 09/26i2017 at 11�09 AM, Personally Known or Ronnie Fussell CLERK CIRCUIT COURT DUVAL Produced Identification U L, COUNTY RECORDING$10-00 TRINFY�ERD TABLE IF-2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(Sam&PLATES),BONDED ROOF COVER System Dock(Note 1) Base Sheet I Roof Cover(Note 14) IVIDP No. I I Type Fasten Attach Base Ply (Psf) SELF-Aomitixo WE PLY: Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-inch o.c.In 4-inch lap and 12-inch o.c.in two SBS-SA,APP-SA,SBS- W-136 inch plywood (poly-film top) or Trufast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows SBS-SA TA,APP-TA .52.5* W-137 Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-inch o.c.In 4-Inch lap and 12-Inch o.c.In two Polyflex SA Base APP-TA -S2.5* Inch plywood (poly-film top) or Trufast 3'Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows W-138 Min.19/32- Elastobase,Elastabase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-Inch o.c.In 4-inch lap and 12-Inch o.c.in two SBS-SA SBS-SA,APP-SA,SBS- _60.0* Inch plywood (poly-film top) (2),equally spaced,staggered center rows TA,APP-TA Min.19/32- Elastobase,Elastob��, 12-Inch o.c.in 4-inch lap and 22-inch o.c.In two W-139 Inch plywood (poly-film top) MG Flat Bottom Plates(square)with Rooforlp#12 (2),equally spaced,staggered center rows Polyflex SA Base APP-TA -60.0* TABLE 1G:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(Note 1) Primer Roof Cover(Nate 14) MDP(psf) No. Joint Treatment Base Ply Ply Cap Ply -140 Min.15/32- None None SBS-SA (Optional)SBS-SA,SB5- SBS_5A,APP-SA,SBS- -90.0 inch plywood TA,APP-TA TA,APP-TA Min.15/32- W-141 I (Optional)PG1D0 None Polyflex SA Base (Optional)APP-TA APP-TA -90.0 Inch plywood M 2 Min.15/32- PG100 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -97.5 I W-1424 Inch plywood TA,APP-TA TA,APP-TA W-143 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled Into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -97.5 Inch plywood place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA W-144 Min.15/32- WB-3000 None SBS-SA (Optional) SBS-SA,APP-SA,SBS- -105.0 Inch plywood I I TA,APP-TA W-145 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SEIS-SA,SBS- SBS-SA,APP-SA,SBS- .135.0 Inch plywood place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Polyflex SA Base (Optional)APP-TA APP-TA -135.0 Inch plywood place to create continuous bond. Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report P9290.02.08-R19 for FL1654-RZI Certificate of Authorization#9503 FIRC NON-HVHZ EVALUATION Revision 19:05/30/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 21 of 56 BMoMg pBogUM 3-TAB ASPRUT SHINGM Frederick, MID * Joplin, MO * Tuscaloosa, AL THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULnNG FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER(BELOW 40-F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT.It is not necessary to remove the plastic ship from the back of the shingles. L ROOF OCCR &FAST� These shingles are for application to roof decks consisting of NAILS:TAMKO recommends the use of nails as the preferred plywood or sheathing boards capable of receiving and retaining method of application. fasteners,and to inclines of not less than 2 in.per foot For roofs WIND CAUTION: Extreme wind velocities can damage these having pitches 2 in. per foot to less than 4 in. per foot, refer to shingles after application when proper sealing of the shingles does special instructions titled"Low Slope Application'.For roofs having not occur. This can especially be a problem it the shingles are pitches greater than 21 in.per foot,refer to special instructions titled applied in cooler months or in areas on the roof that do not receive "Mansard Roof or Steep Slope Roof". Shingles must be applied direct sunlight. These conditions may impede the sealing of the property. TAMKO assumes no responsibility for leaks or defects adhesive strips on the shingles.The inability to seal down may be resulting from improper application,or failure to property prepare compounded by prolonged cold weather conditions ancl/or blowing the surface to be roofed over. dust In these situations,hand sealing of the shingles is required.To insure immediate sealing,apply 4 quarter-sized dabs of TAM-PROO NEW ROOF DECK CONSTRUCTION:Roof dock must be smooth, Premium SBS Adhesive or TAMIKO Tam-Seal Adhesive on the back dry and free from warped surfaces.It is recommended that metal of the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and drip edges be installed at eaves and rakes. 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly PLYWOOD:All plywood shall be exterior grade as defined by the into the adhesive-For maximum wind resistance Wong rakes,cement shingles to the underlaiyment and each other in a 4 in.(1 02mm)width Engineered Wood Association.Plywood shall be a minimum of 3/8 of TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Caution: in.thickness and applied in accordance with the recommendations Apply ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm) of the Engineered Wood Association. thick.Excessive amounts can cause blistering of the shingles and SHEATHING BOARDS: Boards shall be well-seasoned tongue- may soften the asphalt in certain undedayments resulting in the and-groove boards and not over 6 in.nominal width.Boards shall asphalt flowing,dripping and staining.Shingles must also be fastened be a 1 in. nominal minimum thickness. Boards shall be property according to the fastening instructions described below. spaced and nailed. Correct placement of the fasteners is critical to the performance of the shingle. If the fasteners are not placed as shown in the 2.WENMMLSME diagram and described below,this will result in the termination of TAMKO's liabilities under the Limited Warranty.TAMKO will not be Inadequate ventilation of attic spaces can cause accumulation of responsible for damage to shingles caused by winds in excess of moisture in winter months and a build up of heat in the summer. the applicable mph as stated in the Limited Warranty.See Limited These conditions can lead to: Warranty for details. 1.Vapor Condensation FASTENING PATTERNS.Fasteners must be placed above or below 2.Buckling of shingles due to deck movement. the factory applied sealant in an area between 5-5/8 in.and 6-7/8 in.from the butt edge of the shingle.Fasteners should be located 3.Rotting of wood members. horizontally according to the diagram below. Do not nail into the 4.Premature failure of roof. sealant.TAMKO recommends nailing below the sealant whenever possible for greater%-And resistance. To insure adequate ventilation and circulation of air,place louvers 1)Standard Fastening Pattem.(For use on decks with slopes 2 of sufficient size high in the gable ends arid/or install continuous in.per foot to 21 in. per foot-)One fastener 1 in.back from each ridge and soffit vents. FHA minimum property standards require end and one 12 in. back from each end of the shingle for a total one square foot of net free ventilation area to each 150 square feet of 4 fasteners.(See Standard Fastening Pattern illustrated below). of space to be vented,or one square foot per 300 square feet if a NAILS vapor barrier is installed on the warm side of the ceiling or if at least orte half of the ventilation is provided near the ridge-If the ventilation openings are screened,the total area should be doubled- N-TOM 6- Area IT IS PARTICULARLY IMPORTANT TO PROVIDF ADEQUATE VENTILATION. Butt Edge (Contnuecl) Central District 220 West 4th St-, Joplin,MO 64801 800-641-4691 02/12 Visit Our Web Site at Northeast DisArict 45M Tamko Dr., Frederick,MD 21701 800-3W2055 Soutt,weast District 23M 35th St, Tusscaloosa,AL 35401 800-228-2&% tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver;CO 80216 800-530-8868 Frederick, MD - Joplin, MO -Tuscaloosa, AL 2) Mansard Fastening Pattern. (For use on decks with slopes 4.UNDEMMIUM greater than 21 in.per foot)One fastener 1 in.back from each end UNDERLAYMENT: An underlayment must be applied over the and one fastener 10-1/2 in.back from each end and one fastener entire deck before the installation of TAMKO shingles.Failure to add 13-1/2 in.back from each end for a total of 6 fastener per shingle. underlayment can cause premature failure of the shingles which is (See Mansard Fastening Pattern illustrated below.) not covered by TAMIKU.-Limited Warranty.' MANSARD FASTENING PATTERN Products which are acceptable for use as undedayment are: NAILS Asphalt Saturated Felt Uadgftments: - TAMKO No.15 Asphalt Saturated Organic Felt Nailing' -------------. ............ 6-7/8" - Any TAMKO non-perforated asphalt saturated organic felt Area - A non-perforated asphalt saturated organic felt which meets ASTM:D226,Type I or 11 or ASTM D4869 Butt Edge Specia!ty Underlayments: TAMKO Peel-N-Stick Felt NAILS:TAMKO recornmends the use of nails as the preferred method Tam-Shield�Synthetic Undedayment of application. Standard type roofing nails should be used. Nail TAMKO TW Metal and Tile Underlayment,TW Underlayment shanks should be madeof minimum 12-gauge wire,and a minimum and Moisture Guard Plus@ (additional ventilation may be head diameter of 318 in.Nails should be long enough to penetrate required. Contact TAMKO's Technical SerAces Department 3/4 in.into the roof deck.Where the deck is less than 3/4 in-thick, for more information.) the nails should be long enough to penetrate completely through plywood decking and extend at least 1/8 in.through the roof deck. Drive nail head flush with the shingle surface. For Asphalt Saturated Felt Underlaymerlj�: I Apply the felt when the deck is dry.On roof decks with slopes Property Driven Improperly Driven 4 in.per foot and greater apply the felt parallel to the eaves (),j3W.ft&­W und-Aft- -Ok- lapping each course of the felt over the lower course at least Xj? _A01-ft 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt may be adversely affected by moisture and weathering.Laying of the felt and the shingle application must be done together. lWtAWXMd ftd.X..ft *-d-pnft For All Other SMiafty Underlayrmnts: ffft d6V8 - - On roof decks with slopes 4 in. per foot and greater apply the underlayment parallel to the eaves in accordance STAPLES:If staples are used in the attaching process,follow the with underlayment written application instructions. The above instructions for placement All staples must be driven with undedayment should not be left exposed for a longer period of pneumatic staplers.The staple must meet the following minimum time than is specified in the underlayments written application dimensional requirements.Staples must be made from a minimum instructions.The final roof covering must be installed before 16 gauge galvanized wire.Crown width must be at least 15/16 in. the structure is exposed to adverse weather conditions,such (staple crown width is measured outside the legs).Leg length should as wind driven rain,high wind,hail,ice storms,etc. be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for reroofing thus allowing a minimum deck penetration of 314 in.The In areas where ice builds up along the eaves or a back-up of water crown of the staple must be parallel to the length of the shingle. from frozen or clogged gutters is a potential problem,TAMKO's The staple crown should be driven flush with the shingle surface. Moisture Guard Plus*, TW Metal and Tile Underlayment or TW Staples that are crooked,underdnven or overdriven are considered Underlayment (or any specialty eaves flashing product) may be improperty applied. applied to eaves,rakes,ridges,valleys,around chimneys,skylights Property Driven Improperly Driven or dormers to help prevent water damage. Contact TAMKO's urxbn*nvn overchvw crooked Technical Services Department for more information- ` - _= Substitute products as shingle underlayment should not be used. 01— 04"—Deckirg CAUTION: DO NOT FASTEN INTO THE FACTORY APPLIED ADHESIVE. (Continued) Central Dist,ic 220 West 4th St., Joplin,MO 64801 800-641-4691 02/12 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St. Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 8OD-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 8OD-530-8868 2 Frederick, MD * Joplin, MO * Tuscaloosa, AL S.APPLAICAT1111111 Ulm us &ME-11111119FING STARTER C.OURSe Astarter course may consist ofTAMKO Shingle Before re-roofing,be certain to irispectte roof decks.AN plywood shall Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral meet the requirements listed in Section 1. surface roll roofing.If self-sealing 3-tab shingles are used,remove Nail down or remove curled or broken shingles from the exisfing roof. the exposed tab portion and install with the factory applied adhe- sive adjacent to the eaves.Attach the starter course with approved Replace all missing shingles with new ones to provide a smooth base. fasterfers along a line parallel to and 3 in.to 4 in.above the eaves Stmngles that are buckled usually indicate warped decking or protruding edge.The starter course should overhang both the eaves and rake nails.Hammer down all protruding nads;or remove dumn and refasten edges 1/4 in.to 3/8 in.If a roll rooting is used,sea]down the shingles in a new location.Remove all drip edge metal and replace with new. in the first course by applying adhesive cement in four spots equally If re-roofing over an existing roof where new flashng is required to spaced to the surface of the starter strip and press the shingle down protect agarist ice dams(freezetthatif cycle of water andlor U-Ne backup on the spots of cement.Plastic cement should be used sparingly, of water in frozen or clogged gutters),remove the old roofing to a point as excessive amounts may cause blistering. at least 24 in.beyond the interior wall fine and apply TAMKOt Moisture SWNGLE APPUCATION:There am three different offset rrx0iods for Guard Pke waterproofing underlayment-Contact TAMKO's Technical applyirV stip shingle&the 4-inch method,the 5-inch method and the Services Department for more information. 6-inch method.By removing different lengths from the first shingle, cutouts in one course 6f shngles do not line up directly with dime of The nesting procedure described below is the prefened method for re- the cotxse below.It is recommended that the shingles be laid accord- roofing over square tab strip shingles with a 5-1/8 in-exposure. ing to one of these methods consistent wrth procedures outlined in ARMNs Residential Asphalt Roofing Manual-This panel will feature the Starter Begin by usM TAMKO Shroe Starter or by cutting 4-inch nx4hod.For information regarding the other methods,please shirwiles into 5-1/8 x 36 inch st;r-This is done by removing ft5-1/8 in. refer to the ARMA Residential Asphalt Roofing Manual. tabs from the bottom aid appiomiately 2 Yx from U-ife top of the shirtgiles CALMON:Never use an alignment system where shingle joints are so that the remaining portion is the same width as the exposure of the closer than 4 in.to one another old shingles.Apply the starter piece so that 0-le self-sealing adhesive lies a"the eaves arid is even with Ifie existing roof The starter strip Dnp Dw* should be wide enough to overhang the eaves and carry water into the gutter.Remove 3 in.from the length of the first starter shingle to ensure F_—ftsl- ad '."L. L of fen) that tl-ie joints from the old roof do not align with the new First Course Cut off approximately 2 in.from the bottom edge of the stiingles so that 0-te gwxjles fit beneath the existing third course and JW Start 3,d-w Drip edge with ffie edge of the starter strip.Start the fist course with a full 36 in. with W�vffd TAWO Start�SIvn* long shwxje and fasten according to the ristructions printed in Section 3. Ejm�sbN Start 2nd So wit d*o. -1h 4'...-d S.LOW SWE APPLICWHIIN On pitches 2 in.per foot to 4 in.per foot cover the deck with two layers of underlayment Begin by applying the underlayment in a 1/2-sheet width aloing the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place a full-sheet width over the 1/2-sheet width Drip edge starter piece,completely overlapping it.All succeeding courses will Drip edge be positioned to overlap the preceding course by 1/2-sheet width.If New shrgles winter temperatures average 25'F or less,thoroughly cement the Laps of the entire underlayment to each other with TAM-PRO or TAMKO exposwe Plastic Roof Cement from eaves and rakes to a point of a least 24 in. e inside the interior wall line of the building.As an alternative,TAMKO's Moisiture Guard Plus"self-adhering waterproofing underlayment may be used in lieu of the cemented felts. Second and Succeeckig Courses-According to the off-set application method you choose to use,remove fte appropriate length from the 7.MMLESM EM=STECP SLGPE ROOF rake end of the first shingle in each succeedwig course,Place the top if the slope exceeds 21 in. per foot (601, each shingle must be edge of the new shingle against die butt edge of the old shingles in the sealed with TAM-PRO SBS Adhesive or TAMKO Tam-Sea[Adhesive courses above.The full waft shingle used on the second course will immediately upon installation.Quarter-sized dabs of cement must reduce the exposure of the first course to 3 in.The remaining courses be applied to shingles with a 5-1/8 in.exposure,use 6 fasteners per will autornatically have a 5-1/8 in.exposure. shingle.See Section 3 for the Mansard Fastening Pattern. (Continued)l Central District 220 West 4th St. Joplin,MO 64801 800-641-4691 02/12 Visit Our Web Site at Northeast District 4500 Tamko Dr. Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St. Tuscaloosa.AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp-, Dallas,TX 75216 SOD-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-53G-SM 3 Frederick, MD e Joplin, MO e Tuscaloosa, AL S.VALLEY APPLICATION 10.MP AND 21310 FASTENING OETAM6 Over the shingle undertayment,center a minimum 36 in.wide sheet Apply the shingles with a 5-1/8 in.exposure beginning at the bottom of TAMKO Nail-FastO,Moisture Guard Plue or a minimum 50 lb-roll of the hip or from the end of the ridge opposite the direction of the roofing in the valley.Nail the underlayment only where necessary to prevailing winds.Secure each shingle with one fastener 5-5/8 in. hold it in place and then only nail the outside edges. back from the exposed end and I in.up from the edge.Do not nail IMPORTANT-PRIOR TO INSTALLATION WARM SHINGLES TO directly into the sealant. PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING TAMKO recommends the use of TAMKO Hip & Ridge shingle SHINGLES TO FORM VALLEY. products.Where matching colors are available,it is acceptable to After valley flashing is in place: use TAMKO's Glass-Sea]or Elite Glass-Seal shingles cut down to • Apply the first course of shingles along the eaves of one of the 12 in,pieces. intersecting roof planes and across the valley. NOTE:Use only Shingles and Hip&Ridge shingles with the Algae Note:For properflow ofwater overthetrimmed shingle,always Relief feature on Glass-Seal or Elite Glass-Seall shingles with the start applying the shingles on the roof plane that has the lower Algae Relief feature- slope or less height, Fasteners should be 1/4 in.longer than the one used for shingles. • Extend the end shingle at least 12 in.onto the adjoining roof. Apply succeeding courses in the same manner,extending them IMPORTANT PRIOR TO INSTALLATION, CARE NEEDS TO BE across the valley andonto the adjoining roof. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE • Do not trim if the shingle length exceeds 12 in.Lengths shouldvary- BENDING SHINGLES IN COOL WEATHER- • Press the shingles tightly into the valley. THESE ARE THE MANUFACTURER'S APPLICATION • Use normal shingle fastening methods- INSTRUCTIONS FOR THE ROOFING CONDITIONS Note:No fastener should be within 6 in.of the valley centerline, DESCRIBED.TAMKO BUILDING PRODUCTS,INC.ASSUMES and two fasteners should be placed at the end of each shingle NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING crossing the valley. I DEFECTS RESULTING FROM FAILURE TO FOLLOW THE • To the adjoining roof plane,apply one row of shingles extending MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW it over previously applied shingles and trim a minimum of 2 in. THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE back from the centerline of the valley UNDER THE LIMITED WARRANTY. SEE THE LIMITED • Clip the upper comer of each shingle at a 45-degree angle and WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS embed the end of the shirigle in a 3 in-wide strip of asphalt plastic REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE cement-This will prevent water from penetrating between the CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT courses by directing it into the valley. 8OD-641-4691. • CAUTION: Adhesive must be applied in smooth, thin, even layers. Excessive use of adhesive will cause blistering to this Direction of prevailing wind product.TAMKO assumes no responsibility for blistering. Start 5'e here- 36'�sde TAMKO cented— Nad Fast-'Moist— NO tasten�wow Fn] Guard Plus'or 50 lb. 61 d centerlirm // W h�a,er.11,00ling fast�r tri Start ard of amoe lered 5"exposure P, erid amile 01111110stirbey-W TAMKCr.Morsture GLard PW,Nal FastO'TAM-PROP and One Glas~are registered Asphalt PM39C vwby C.Arhm tradernarks of TAMKO 8�Products,Inc. ceffierd "r Clipped off Inforrnabon included in trwm application kisftuctions was current at bme of pnnfing at 45* To obtwn a copy ofthen cLaTent version of ftm3se applicabon instructions,vrsit us online at tan"corn or call Lis at 800-641 A691 SitingotaftiewdT back kurr�va%y ow*ork* FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 800-641-4691. Central District 220 West 4th St-, Joplin,MO 64801 800-641-4691 02/12 Visit Our Web Site at Northeast District 45M Tamko Dr, Frederick,MD 21701 800-368-2055 Southeast District 2300 35th SL, Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 8OG-443-1834 Western District 5300 East 43rd Ave.. Denver.CO 80216 800-530-8868 4 SHINGLE DOG 15w GUIA DE INSTALACION SHOME WG 15'es un revestinyiento sint6ft para techos,chwfiado Wa reemplazat la tela asfiltica saturada#15 y para usarse solo debalo de telas de asWW. SHIWAE DOG 15"es una.barrm de vapor y par lo tanto debe de instalarse sobre espacios con una ventiflaci6n adecuada.La swperficie de ia cubmta debe ser de una inclinad6n de 2:12 o nsayor,debe de estar seca y bbre de polvo,sudedad,aguieros,clavos sueltos y otras pmtubemcias-Para indinaciones entre 2-12 y 4:1Z superponga el Tecubnmmft a la mitad.SHWU DDG Ir no estA disefiado paTa seT la cubmU final y pnncipal del techo y debe ser cubierto dentro de un plazo de 30 dias despu6s de la mstalad6n. SHMM DOG Ir se instala paralelamente a Us canaWas can el lado imprm hacia aniba.Use bwm hoTizonta)es de 3"(15 cm)y trams verticales de 6'Mm).Los tram mperpuestos deben de segurr el caudal de la Ruvia en fonna de capas.Aphque SHMUE DOG IS"a tDdos los empaIrnes al raenos a una altura de 6'(Ikm� Para mWdo el mism dia,se deberAn de instalar sujetadores en donde indiEa la marca impresa que es para los,sujetadores,se puede haceT ya sea con clavos para techo resistentes ak wrrosi&con cabeza de por lo mews 3/8 de pulgada o con clavos para.Ww de cabeza,de plistim o grapas con cabeza de pikstico que cuenten poT lo vwnos de una pukjada de dimetro.Los s*tadores estarin a 90*de]a superficie del techo y no deberin ser muy ernpujados o protuberantes.NO UTIUZAR GRAFAS,el uso de qTapas invalida]a garantia SHINGLE DOG IS-. Para exposicidn de hasta 30 dias,Jos sAgetadores seTh instalados en donde indica la marca impresa que es para los sujetadores,con davos paTa techo con cabm de metal o plisfico de un minim de r de dUrnetm los suietadores estarin a 90"de]a superficie del tedw y no deberin set muy empu*os o protuberantes.Adernis se recomienda,duplicar el ancho de la!�superposicfones,poner cinta en Us junturas,doMaT]as superposiciones antes de colocar los davas y/o usar un selladoT compatilAe entre cada tram Repare cualquier"adura,agujeTo o-dafio de la superfide de]a cubierta,con un sellador ompatiNe o con una cinta adhesiva de revestimiento paTa exteriores. AsegWese que cualqweT suletadoT que haya sido colocado mcorrectaTneribe sea sellado o se le apNue silic6n,paTa preveniT cualquieT posibilidad de hurnedad. I HORIZONTAL LAP NAILS 11 (28 cm) 0 LAP 311 V.6 cm) SHINGLE o. SHINGLE nma 0- RELD 22" (m Gm) 0- DOG "-Immm� — E 4%E) LU z Co V 0 cc LU > SYNTHETIC UNDERLMIENF SVNTHIEM UNDERLAYMENT SIDE LAP 6" (15.24 cm) Cow W_)_nkgp,�p_Who,M_M up Us pdcb_de_g_"Ma te�(O%W y im o&�loWn de segundad y amOnicri6n.lenga cuW[ado cuando annine o esti VaTado solbre SHIVAE DOG 1S-.La hmnedad,el md%el pokvi U VdM el bieK mmihm y otras condkiones dd sitio laboral pledn Gunbju el mekkT&de fj joj6, de SHROGE DOG is-a]owdenw/durmft/despuis de la fnstabd6m 0 no utilbw el equipo de segmidad y zapatos adecuadus puede ocasiam un auidente grm o la medr- TM SHINGLEDOGUMM SHINGLE DOG 855.602.209S PO BOX TMS,592 SHEPPARD AVE.WEST, RFVFSTIMIFNT() SINTFTICO ME r%n�C%nLtV ^MATA06^rAIUAna m2u cal