Loading...
1975 Jordan St modified roof permit j LyrJv CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF17-0009 Description: Modified Bitumen Roof Estimated Value: 5981 Issue Date: 10/13/2017 Expiration Date: 4/11/2018 PROPERTY ADDRESS: Address: 1975 JORDAN ST RE Number: 172106 0000 PROPERTY OWNER: Name: JORDAN THEODORE L Address: 1975 JORDAN ST ATLANTIC BEACH, FL 32233-4371 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: ROGERO &WILLIAMS ROOFING CONTRACTORS IN Address: 883 Lawhon Dr ST JACKSONVILLE, FL 32259 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. rS.ailf yer, City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) r 800 Seminole Road Room— 1••� Atlantic Beach, Florida 32233-5445 Roo /— Phone(904)247-5826 • Fax(904) 247-5845 ) -7 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1175 Soe-�n Sk• PaKrItment review required Ye No ll uildin ` Applicant: S(Zd&g Planning &Zoning Tree Administrator Project: t&&, (A.84'_A Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date C 0 n4 rG C�a of Permit Verified B eq m ,L Florida Dept. of Environmental Protection Florida Dept. of Transportation P f �� St. Johns River Water Management District (Dorman `f Army Corps of Engineers Division of Hotels and Restaurants ( CJ Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS p, Reviewing Department First Review: []Approved. Knied. ❑Not applicable (Circle one.) Comments: =BUILDING PLANNING &ZONING Reviewed by: Date: Z t1 .t1 TREE ADMIN. Second Review: ❑Approved as revised. [gdenied. []Not applicable PUBLIC WORKS Comments: ri CO rn�Le -4( PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. ❑Not applicable Comments: Reviewed by: Date: 10 —9-17 Revised 05/19/2017 S Uj- . CITY OF ATLANTIC BEACH f 800 Seminole Road �r Atlantic Beach,Florida 32233 : `ff;,,; OFFICE COPY REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date S ( 7 Revision to Issued Permit' Corrections to Comments `-Permit# R00 17-000 C Project Address I T 7 5 J c ziJ Ati 7 Contractor/Contact Name ROCS CRO "t Phone S i e) - c'4- Email e- L 107 41(,,, (2- n,\ccLl . co rn Description of Proposed Revision/Corrections: Permit Fee Du Ros!)(- i2© � — No D LD 0--c DA -1A Additional Increase in Building Value $ Additional S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: ui m /T1- 'ng & Zoning Reviewed By Tree Administrator Public Works Public Utilities Public Safety Date Fire Services CITY OF ATLANTIC BEACH 111 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 _ (904)247-5800 r�JJiI�r BUILDING DEPARTMENT REVIEW COMMENTS Date: 7/17/17 Permit#: ROOF17-0009 Applicant: Ro ero Williams Site Address: 1975 Jordan Address: 3415 Kori Rd. Review: 1 Phone: 518-5463 RE#: I I I Email: I T ul725 rwcontractors.com THIS BUILDING DEPARTMENT REVIEW IS ONE OF 1 DEPARTMENT REVIEWS. PLEASE FIND ALL DEPARTMENT REVIEWS AND ADDRESS ALL COMMENTS. Correction Comments: Application is disapproved for the following issues: 1. Installation instructions for flat, tile,and metal roofing must be submitted with the permit application. The technical product data, submitted, is not specific and the Florida Product Approval has several options that must be indicated. Please submit two copies of the Florida Product Approval installation instructions with all proposed options indicated. Start on Table 1, indicating proposed system and proceed to back pages, indicating all options, including methods and materials. f 2 17 Pn erna; 11 -/v T'arrrr.o r✓1 rc;� c ar�o� acts �'y M v 1 �-i ��►" S9T /v� r /'Y1 Pe i yi S �ti 7 hio L(/ hQ r Rvv �r d�Z y/�? S( ole-e jcp k/ "h -'PVUw, �-00-�' 1 Building Permit Application OFFICE COPY City of Atlantic Beach 800 Seminole Road,Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (904)247-5845 Job Address: Permit Number: Legal Description g•L4 ►�j- ZSQ9 F. 1—C* Z erLZ—CZ RE# Kscz CJ k -10-Loll• 2�3 Valuation of Work(Replacement Cost)$ S9$\.00 Heated/Cooled SF 10JS Non-Heated/Cooled 2o°I • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structures) (Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/ • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: 0 % Qrlp= Ig Florida Product Approval# V= . 33- for multiple products use product approval form Property Owner Information 1 Name: be��f< .t'-1 lock Address: 197IS :TDI& .� Cs =4r city—PA36,ttAAc, G4-(irli State\• Zip Phone E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: TZol-x L LADW• Nms Qualifying Agent: Address 34t5 1Lr)r1 CityTPLState Zip '7 Office Phone 9U-A- •SyAU:5 Job Site/Contact Number State Certification/Registration# CCC13303SGn E-Mail A:,,lLL 1�srwC_On-Vy0t[,\(X5 . ('-DM Architect Name&Phone# Engineer's Name&Phone# Workers Compensation WC ZO 17 C7 00O (--> p 1 1 Exempt/Insurer/Lease Employees lExpiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTIC17F COMMENCEMENT Co v (Signature of Owner or ftfit including Contractor) (Signature of Contractor) Signed and sworn to(or affi d)before me this i(O day of Sig d and sworn to(or affirmed)before me this 1k day of Smart 2ot ,by _��a —7pkkC .by PAUL ROBERT CAS, of Notary) (Signature of Notary) Commission q �E 39155 E' : ROBERT CAS:ETU My Cummission E rpiresmission A FF 3A168July 24, 2U1 7 Commission Expire Personally Known OR July 24, 201 7 ('Produced Identification [ flProduced Identification Type of Identification: ter %ye_vs e e.o�nD� Type of Identification: CITY OF ATLANTIC BEACH Jv '�6 800 Seminole Road " COPYAtantliec B , lorida 32233 s1 TeOFFICE one(904)247-5800 FAX(904)247-5845 REVISION REQ EST SHEET OR O CTION O REVIEW CO NT Date: S 17-- eceived by: esubmitted: Permit Number: ROOF( " O Original Plans Examiner: Project Name: Project Address: S or-60.A Contractor: pGE;20 E 11, L , S Contact e: Contact Phone : ( $-S G 3 Contact a-mail Revision/Plan Check/Permit Fee (s) ue: $ Description of Proposed Revision to Ex tin Per t: TJn ",:S EMA.t 0 • S5 (Jonce �Uc o T Additional Increase in Building Value: Additional S.F. Site Plan Revised: ublic W/U Approval: By signing below. I(print name) affirm that the above revision is inclusive of the proposed changes Signature of Contractor/Agent i //(Cogtractor must sign if increase in valuation Date Office Use Only AA i Date: //Ap oved: Rejected: Notified by:: Plan Re iew Co nts: ,,Depaftnapent review required Yes No Building anning 8,Zoning Tree Administrator Plans Examiner Public Works Public Utilities !!� Public Safety Date Created 4/13/16 Rev.3 Fire Services OFFICE COPY Doc # 2017140482, OR BK 18019 Page 1091, Number Pages: 1, Recorded 06/15/2017 at 08:55 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 NOTICE OF COMMENCEMENT ,PREPARE IN aUPLICA1Fa Permit No. Tog roilo No. _- - Steteot County of QQ%jck. To whole It may concern; The undarskjned hereby Informs you that Improvomonts will be meds to certain red property,and In acordanee with Section 713 of the Florida Statutes,the following hlfonnatlon Is stated In this NOTICt'.Ot' IMENCEMENT. Legal description of property being Improved: 12 - E (\ L � - D c n p 0 t3� T7o ZS - Z3 3�i Address of property being improved' 19 r7S General description of Improvements: I F Owner tTOC6o'✓1y ThinC�Otom, L — Address [97S Tar4- aTIi, CrInC_ 1�1 Owner's Interest In site of the Improvement n'n:ct, — Fea Simple Titleholder(If other than owner) Norale RtZew and Wlaarns aulldlnp and Rmt[na CmIm0an Address 3415 Karl Road,1 al:ksonvlle Florida 37257 Contractor emmey s.Rogero Address 3415 Kort Road,1 acksonvOr Florldi 3=7 Phone No. e04-sae.S463 Fox No.904'619'1400 Surety(it any) Address Amount of bond Phone No. Fax No. Name and addfess of any person rnaking a loan for the construction of the Improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other Ihon himself,designated by owner upon whom notices or ottwr documents may be served: Name 1 eremey 5.Roltwo Address 3415 Kori Road,J aeksonvllle Florida 32257 Phone No. 904.51&5463 Fax No.904-Gl 9-2400 In addlllon to himself,owner desklnstes the following person to receive a copy of the i-lencr's Notice as provided In Section 713,06(2)(b).Florida Statutes.(1.91 In at Ownef's option). Noma Address Phone No. Fax No. Expiration date of Notice of Commencement(Ute expiration date Is one(1)year from the data o1 recording wtless a different data Is specified): THIS SPACE FOR RECORDER'S USE ONLY OW R - � Slgrrrd:� seforen»1 y Cole r Duvet to o a FI Id Jit o f ppaend S_ Jit train t+y WITIVAlr iwrsvif trd a111ms Ihel d:tiouMentisand daclwullowhwtlo are Oros and emirate • r PAUL ROIERT CASSETTA e Commission s FF 391&6 My Commission Expires July 24, 2017I Pvbi k:al Large,Sid t t *tool. . i io rnom w Known _---_ —a ibe' itainTeed •:• TeChniCal prodUCt I FLINTLASTIC° GTATM APP MODIFIED BITUMEN ROLL ROOFING PRODUCTS Product Product Use: FLINTLASTIC GTA is designed for use as a roofing membrane over various types Information of substrates for both new construction and reroofing installations. It is suitable for most low sloped roof decks and may be used for roof system flashings including wall treatments, base flashings and field flashings. Limitations. FLINTLASTIC GTA is intended for torch application only and should not be exposed to adhesives or solvent based materials. Rolls should be stored upright, off ground, completely protected from the weather. Roof decks shall be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed. Additional specifications and precautions are contained in the CertainTeed Commercial Roof Systems Manual. Product Composition and features: FLINTLASTIC modified bitumen membranes are manufactured on state-of-the-art, dedicated roofing lines that were exclusively designed for the production of modified bitumen products. FLINTLASTIC GTA is produced with a high performance, non-woven polyester mat which is impregnated and coated with a superior grade, modified bitumen compound. Roll Dimensions. 393/8" X 32' 10" Coverage: One square Approximate Weight. 105 lbs. per roll Top Surface: Mineral Granule Back Surface: Torchable Polyethylene Film Applicable Standards:Meets ASTM D6222, Grade G, Type I. FLINTLASTIC GTA is approved by Underwriters Laboratories for use in various Class A, B, and C roof CR C assemblies, ICC-ES (ESR-1388), Factory Mutual, Miami-Dade, Florida Building ..�. Code Statewide Approval (FL 2533), and Texas Department of Insurance (RC- 47). FLINTLASTIC GTA White is an approved ENERGY STAR® product for slopes greater than 2"/12". Initial Solar Reflectance: 0.27; Aged Solar Reflectance: 0.27; Thermal Emittance: 0.87. FLINTLASTIC GTA White is approved by the Cool Roof Rating Council (CRRC). The CRRC product ID is 0668-0008. Modified Bitumen Coating: Non-oxidized (flux) asphalt, blended with various thermoplastic atactic polypropylene polymers and co-polymers. Technical SupportMat: High performance, puncture and tear resistant, non-woven polyester mat. Data Test Description Test Method Results* Solar Reflectance Index(SRV: ASTM E1980 27 Softening Point: ASTM D36 310°F Tensile Strength: ASTM D5147 @ 73.4+/- 3.6°F MD/XD 105/60 lbs./in. @ 0 +/- 3.6°F MD/XD 130/80 lbs./in. Elongation: ASTM D5147 @ 73.4 +/- 3.6°F MD/XD 50%/55% @ 0 +/- 3.6°F MD/XD 30%/20% Dimensional Stability: ASTM D5147 MD/XD 0.5%/0.3% Low Temperature Flex: ASTM D5147 Pass @ 8°F Compound Stability: ASTM D5147 250°F Thickness: ASTM D5147 4.2mm (168 mils) Tear Strength: ASTM D5147 @ 73.4+/- 3.6°F MD/XD 155/95 lbs. *NOTE:Published results are nominal production values confirmed by independent laboratory testing. S X TRINITY'ERD I TABLE 1B: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER EM TYPES: MECHA r,LLY ATTACHED SASE INSULATION,BONDED TOP INSULATION,BONDED.- Sys tem ONDEDSystem Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP(psf) No. (Note 1) Type Fasteners Attach Type Attach Base Ply Cap HYBRID SYSTEMS: Min.15/32-Inch Min.1.5-inch ACFoam FlintFast#12 or Min.1.5-inch ACFoam II, HA,D-IS,M- W 13 exterior grade II,FlintBoard 150,H- #14 with 1 pert.33 FlintBoard ISO,H Shield or OSFA,M PGl 565 SAH (Optional)APP TA APP TA 67.5 plywood at max.24- Shield or FlintBoard FlintFast 3" ft FlintBoard ISO,, or 09500 inch spans ISOH. Insulation Plates CONVENTIONAL SYSTEMS: Min.23/32-Inch Min.0.5-inch FM Approved BP-AA, Min.1.5-inch ACFoam (Optional) exterior grade : Wood Fiberboard,min. BP-AA or SBS-AA,SBS- * W-14 plywood at max.24- 11,FlintBoard G3,H- ISO, Note 2 1 per 2 ft0.75-inch FM Approved HA SBS AA SBS-AA,SBS-TA or TA or APP-TA 45.0 inch spans ENRGY 3,H-Shield perlite APP-TA Min.23/32-inch Min.0.25-inch SECUROCK BP-AA,SBS (Optional)BP-AA, Min.1.5-inch ACFoam ( P� ) exterior grade x Gypsum-Fiber Roof Board, SBS-AA,SBS- * W-15 plywood at max.24- Il,FlintBoard G3,H- ISO, Note 2 1 per 2 ftDens Deck or Dens Deck HA AA,SBS-TA SBS-AA,SBS-TA or TA or APP-TA 45.0 inch spans ENRGY 3,H-Shield Prime or APP-TA APP-TA Min.15/32-Inch Min.1.5-Inch ACFoam FlintFast#12 or Optional additional layer(s) HA D-IS,M- exterior grade II,FlintBoard ISO,H- #14 with 1 per 1.33 of base insulation followed W-16 plywood at max.24- Shield or FlintBoard FlintFast 3" ftZ by Min.0.25-inch SECUROCK OSFA,M-PG1 APP-TA (Optional)APP-TA APP-TA -90.0 inch spans ISOH. Insulation Plates Gypsum-Fiber Roof board or OB500 O n n ) M C-) 0 -v Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report 3520.03.04-R19 for FL2533-R18 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 19:06/06/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Corporation;(610)651-5847 Appendix 1,Page 7 of 57 TRINITY i ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-6 18 Wood New,Reroof(Tear-Of)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 7 1C Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 8-9 1D Wood New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 30-12 1E-1 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech,Attached Base Sheet,Bonded Roof Cover 13-15 1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16-17 1F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 17 2A Steel or Structural Concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 18-20 2B Steel or Structural Concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 21-25 2C Steel or Structural Concrete New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 26-28 3A Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 29-36 3B Concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 36 3C Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 37 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 38-39 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 40 4C LWIC New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 41-44 SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 45 5B CWF New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 46 5C CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 46 5D CWF New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 48-49 6B Gypsum Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 50 6C Gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 51 6D Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 51 O 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 52-57 _n 76 Various Recover F Non-Insulated,Bonded Roof Cover 57 —n The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the m roof deck shall be documented through proper codified and/or FBC Approval documentation. ^ 2. Unless otherwise noted,fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ` , ➢ Wood Deck: OMG#14 Roofgrip with Flat Bottom Plate(Accutrac),OMG HD with OMG 3 in,Galvalume Steel Plate,Dekfast#14 with Hex Plate or 3"Round Insulation Plate,Trufast HD with Trufast 3" O Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: OMG#12 or#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac),OMG#12 Standard or HD with OMG 3 in.Galvalume Steel Plate,Dekfast#12 or#14 with Hex Plate or 3"Round Insulation Plate,Trufast DP or HD with Trufast 3"Metal Insulation Plates or FlintFast#12 or#14 Fastener with FlintFast 3"Insulation Plates. Minimum 0.75-inch steel penetration and �\ engage the top flute of the steel deck. ➢ Structural Concrete: OMG#14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast#14 or DekSpike with Hex Plate or 3" Round Insulation Plate,Trufast HD or CF with Trufast 3"Metal Insulation Plates or FlintFast#14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report 3520.03.04-1119 for FL2533-R78 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 19:06/06/2017 Prepared by: Robert Nieminen,PE-59166 CertainTeed Corporation;(610)651-5847 Appendix 1,Page 1 of 57 OFFICECORY - TRINITYERS 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic®Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following CertainTeed products make up the subject systems. TABLE 1:ROLL-GOODS FOR FLINTLASTIC®MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Flintlastic®SA NailBase ASTM D4601 N/A II Glasbase"Base Sheet ASTM D4601 N/A II All Weather/Empire'"Base ASTM D4601 N/A II Base Sheets Flexiglas-Base ASTM D4601 N/A II Flintlastic-Base 20 ASTM D4601 N/A II Flintlastic Poly SMS Base Sheet ASTM D4601 N/A 11 Yosemite®Venting Base ASTM D4897 N/A II Ply Sheets Flintglas°Ply 4 ASTM D2178 N/A IV Flintglas®Premium Ply 6 ASTM D2178 N/A VI Flintlastic®APP Base T ASTM D6509 N/A N/A Base/Ply Membranes(APP) Flintlastic®STA ASTM D6222 S I Flintlastic®STA Plus ASTM D6222 S I Flintlastic®STA ASTM D6222 S I Flintlastic®STA Plus ASTM D6222 S I Cap Membranes(APP) Flintlastic®GTA ASTM D6222 G I Flintlastic®GTA CoolStar— ASTM D6222 G I Flintlastic®GTA-FR ASTM D6222 G I Flintlastic®GTA-FR CoolStarT" ASTM D6222 G I Flintlastie SA PlyBase ASTM D1970 N/A N/A "fIII, ASTM D1970 N/A N/A FlintlastiC SA Mid Ply ASTM D6163 S I Base/Ply Membranes(SBS) Flintlastic Ultra Glass SA ASTM D6163 S I Flintlastic Base 20 ASTM D6163 S I Flintlastic Base 20 T ASTM D6163 S I Flintlastic Ultra Poly SMS Base Sheet ASTM D6164 S I Flintlastic FR Dual Cap ASTM D6162 G I Flintlastic SA Cap FR ASTM D6163 G I Flintlastie SA Cap FR CoolStar- ASTM D6163 G I Flintlastic Cap 30 ASTM D6163 G I Flintlastic Cap 30 Cp rTM ASTM D6163 G 1 —Fi�intlasfiC FR Cap 341M ASTM D6163 G I Flintlastic FR Cap 30 CoolStar- ASTM D6163 G I Flintlastic FR Cap 30T ASTM D6163 G I Flintlastic FR Cap 30 T CoolStar— ASTM D6163 G I Flintlastic SA Cap ASTM D6164 G I Flintlastic SA Cap CoolStar- ASTM D6164 G I Cap Membranes(SBS) Flintlastic FR-P ASTM D6164 G I Flintlastic FR-P CoolStar— ASTM D6164 G I Flintlastic GMS ASTM D6164 G I Flintlastic GMS CoolStar— ASTM D6164 G I Flintlastic GTS ASTM D6164 G II Flintlastic GTS CoolStar— ASTM D6164 G II Flintlastic GTS-FR ASTM D6164 G 11 Flintlastic GTS-FR CoolStar— ASTM D6164 G 11 Flintlastic Premium FR-P ASTM D6164 G II Flintlastic Premium FR-P CoolStar- ASTM D6164 G 11 Flintlastic Premium GMS ASTM D6164 G II Flintlastic Premium GMS CoolStar— ASTM D6164 G II Exterior Research and Design,LLC. Evaluation Report 3520.03.04-1119 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION FL2533-1138 CertainTeed Corporation Revision 19:06/06/2017 Page 4 of 6 CertainTeed Technical Data FLINTLASTIC® GTATMOFFICECOPY APP MODIFIED BITUMEN ROLL ROOFING PRODUCTS Product Product Use:FLINTLASTIC GTA is designed for use as a roofing membrane over various types Information of substrates for both new construction and reroofing installations. It is suitable for most low sloped roof decks and may be used for roof system flashings including wall treatments, base flashings and field flashings. Limitations:FLINTLASTIC GTA is intended for torch application only and should not be exposed to adhesives or solvent based materials. Rolls should be stored upright, off ground, completely protected from the weather. Roof decks shall be structurally sound, dry, smooth and meet or exceed minimum requirements of the deck manufacturer, local code and CertainTeed. Additional specifications and precautions are contained in the CertainTeed r Commercial Roof Systems Manual. Product Composition and Features:FLINTLASTIC modified bitumen membranes are manufactured on state-of-the-art, dedicated roofing lines that were exclusively designed for the production of modified bitumen products. FLINTLASTIC GTA is produced with a high performance, non-woven polyester mat which is impregnated and coated with a superior grade, modified bitumen compound. Roll Dimensions: 393/8"X 32'10" Coverage. One square Approximate Weight: 105 lbs. per roll Top Surface. Mineral Granule Back Surface: Torchable Polyethylene Film Applicable Standards:Meets ASTM D6222, Grade G, Type I. FLINTLASTIC GTA is approved by Underwriters Laboratories for use in various Class A, B, and C roof assemblies, ICC-ES (ESR-1388), Factory Mutual, Miami-Dade, Florida Building CR C Code Statewide Approval (FL 2533), and Texas Department of Insurance (RC- 47). FLINTLASTIC GTA White is an approved ENERGY STARO product for slopes greater than 2"/12". Initial Solar Reflectance: 0.27; Aged Solar Reflectance: 0.27; Thermal Emittance: 0.87. FLINTLASTIC GTA White is approved by the Cool Roof Rating Council (CRRC). The CRRC product ID is 0668-0008. Modified Bitumen Coating:Non-oxidized (flux) asphalt, blended with various thermoplastic atactic polypropylene polymers and co-polymers. Technical Data Support Mat:High performance, puncture and tear resistant, non-woven polyester mat. Test Descriation Test Method Results* Solar Reflectance Index(SRI): ASTM E1980 27 Softening Point: ASTM D36 310°F Tensile Strength: ASTM D5147 73.4+/-3.6°F MD/XD 105/60 lbs./in. 0+/-3.6°F MD/XD 130/80 lbs./in. Elongation: ASTM D5147 ®73.4+/- 3.6°F MD/XD 50%/55% ®0+/-3.6°F MD/XD 30%/20% Dimensional Stability: ASTM D5147 MD/XD 0.5%/0.3% Low Temperature Flex: ASTM D5147 Pass®8°F Compound Stability: ASTM D5147 250°F Thickness: ASTM D5147 4.2mm (168 mils) Tear Strength: ASTM D5147 73.4+/-3.6°F MD/XD 155/95 lbs. 'k ;NOTE:Published results are nominal production values confirmed by independent laboratory testing. Product FLINTLASTIC modified bitumen roofing systems shall be applied in accordance with installation Application procedures contained in the CertainTeed Commercial Roof Systems Manual. The following information is intended for general information purposes only and is not all-inclusive. Preparation.Substrates to receive a roof system shall be firmly attached, smooth, dry, clean and free of sharp projections and depressions. Substrates requiring priming shall be primed with asphalt primer such as CertainTeed's FlintPrime-and be allowed to completely dry. Substrates shall provide positive drainage. Roof shall be tapered to drains. Installation: Install one ply of GLASBASE or other CertainTeed approved alternate base sheet lapping 2" on sides and 4" on ends. Base sheet shall be mechanically fastened to nailable substrates, and either solid or spot mopped in hot asphalt to non-nailable or insulated substrates as specified in the OFFICE COPY CertainTeed Commercial Roof Systems Manual. Apply base sheet in such a manner to provide and maintain a minimum 6" offset between side and end laps of base ply and FLINTLASTIC finishing membrane. Over the base ply, install one ply of FLINTLASTIC GTA lapping 3" on sides and 6" on ends with end laps diagonally staggered not less than 3 feet apart. Side and end laps should be inspected to ensure a minimum 3/8" flow of modified compound has been achieved. Precautions:Cold weather applications require special handling to prevent damage to the rolls and to ensure satisfactory installation. Do not apply roofing systems over improperly prepared substrates or substrates which contain moisture. Follow all safety recommendations relating to the use and maintenance of liquid propane gas torches and equipment. Refer to the CertainTeed Commercial Roof Systems Manual for additional safety information. Maintenance: FLINTLASTIC Roof Systems do not require any additional maintenance beyond normal yearly roof maintenance procedures. CertainTeed recommends regular roof maintenance and inspection to determine the condition of drains, flashings and other similar items, and to prolong the life expectancy of the roof system. Warranties CertainTeed offers a number of different types of Roof Membrane Warranties designed to meet the building owner's specific requirements. Please contact your nearest CertainTeed office for additional information and requirements. Technical CertainTeed provides technical assistance in the design, selection, specification and application Assistance and guidelines for all CertainTeed Roof Systems. Architectural and field representatives are available for consultation within each region. Services For more information, contact CertainTeed's Technical Support at 800-396-8134 x2. Caution: Torch application of this product may create a risk of FIRE, including SMOLDERING FIRES. Fire Hazard The roofing applicator is solely responsible for ensuring and enforcing safe and proper application of CertainTeed's roofing products by competent and qualified personnel. Only properly trained roofing professionals are authorized to install this product. Never apply flame directly to combustible materials or allow the flame to enter into hidden or protected areas that may contain combustible materials. Follow all local code requirements. Have a Class A-B-C fire extinguisher available to each applicator. Thoroughly inspect the job site whenever torching equipment has been used. Be certain that all chances of a fire have been eliminated. Refer to the CertainTeed Commercial Roof Systems Manual, Midwestern Roofing Contractors Association (MRCA) CERTA program, National LP Gas Association, National Roofing Contractors Association (NRCA), National Fire Protection Association (NFPA), and Asphalt Roofing Manufacturers Association (ARMA) for further information and safety recommendations. ASK ABOUT ALL OF OUR OTHER CERTAINTEED® PRODUCTS AND SYSTEMS: CertainTeed Corporation P.O. Box 860 ROOFING SIDING • TRIM • DECKING • RAILING • FENCE • FOUNDATIONS Valley Forge, PA 19482 GYPSUM CEILINGS • INSULATION • PIPE Professional: 800-233-8990 www.cortainteed.com http://blog.certainteed.com Consumer: 800-782-8777 -L,07112 CertainTeed Corporation,Printed in the U.S.A. _ Code No.COMM-020 SAINT GOBAIN GindlespergerJoni From: Tammara Yuhas <tyuhas@rwcontractors.com> Sent: Tuesday, August 15, 2017 10:34 AM To: Building, Dept Subject: FW: Permit Application for 1975 Jordan Street Attachments: abpermit.pdf This is actually the third time that I have sent this to you. I really appreciate your time and help expediting this for us. You're the best. OFFICE COPY W� Tammara Yuhas Project Manager Assistant Rogero&Williams Roofing Contractors 3415 Kori Road Jacksonville, FI. 32257 Main: 904-518-5463 Fax: 904-619-2400 From:Tammara Yuhas Sent:Tuesday,July 18, 2017 4:55 PM To: 'Building-Dept@coab.us' <Building-Dept@coab.us> Cc: Paul Cassetta <pcassetta@rwcontractors.com> Subject: Permit Application for 1975 Jordan Street Good afternoon, Attached to this email is the permit application and product approval sheets needed. If you need anything further please do not hesitate to contact me using the contact info below this message. yvff" Tammara Yuhas Project Manager Assistant Rogero &Williams Roofing Contractors 3415 Kori Road Jacksonville, FI. 32257 1