720 AQUATIC DR - PERMIT REVIEWS 1 >1 :rje
/ s
Permit Reviews
City of Atlantic Beach
Permit Number: RESA17-0015 Description:SCREEN ROOM
Applied:8/17/2017 Approved: Site Address:720 AQUATIC DR
Issued: Finaled: City,State Zip Code:Atlantic Beach,Fl 32233
Status: RECEIVED Applicant:<NONE>
Parent Permit: Owner:SIM KAYLA
Parent Project: Contractor:<NONE>
Details:
LIST OF REVIEWS
RETURNED
SENT,:-.DATE, ., DUE DATE TYPE CONTACT ,STATUS REMARKS
ar. a DATE
Review Group:2ND REVIEW
10/26/2017 10/26/2017 11/6/2017 ZONING Brian Broedell APPROVED Approved Variance
Notes
Approved via variance=ZVAR17=0005 at°Community Development Board Meeting on October 17,2017
nk �.
Review Group:AUTO
8/17/2017 10/27/2017 SUBMITTAL Permit Tech APPROVED
COMPLETENESS
Notes
8/17/2017 8/24/2017 8/28/2017 ZONING Brian Broedell DENIED
Notes
TownRequirements:
-house Requirements ,Section 24=88(c),requires that townhomes be constructed at substantially the same time The proposed addition violates
this requirement andktherefore cannot be approved Section 24 88(c)specifically states,"Adjoining two-family or;townhousedwellings units4shall be
constructed at substantially the same time or in a continuous sequence unless an existing:structure is being renovated within thesame building
footprint" °
8/17/2017 8/23/2017 8/28/2017 BUILDING Building DENIED
Notes
affidavits are needed One for a screen enclosure and the other for attaching a structure to an existing structure I will attach the formsafor these,
affidavits to the email Itsend you I need;them completely filled,outand 2 copies each w °
2 Aluminum=structure plans are site specific and needuto be.signed and sealed by an engineer. r t
8/17/2017 8/18/2017 8/28/2017 PUBLIC WORKS Public Works APPROVED Received at PW
W/CONDITIONS 8/18/17
N otes
See Conditions of Approval that will be printed°on Permit.
OpPrinted:Wednesday,08 November,2017 1 of 2
s '
AFFIDAVIT FOR ATTACHING A NEW STRUCTURE TO AN EXISTING STRUCTURE
TO: Building Inspection Department,City of Atlantic Beach,800 Seminole Road
Home Owner:
Name
Street Address
City.State and Zip Code
Contractor..
Permit Number -
As the Contractor for the proposed new structure located at the above address,I have personally viewed
with the above named home owner those portions of the existing structure on which portions of the
proposed new structure are to be attached for structural support.I am confident that the drawings and
details included with this permit application depict the existing conditions of the host structure,and the
members of the existing structure upon which the new structure are to be attached are sound with no rot
or deterioration. The home owner has been advised by me that,in my best judgment based on experience
and knowledge of structural adequacy,the members of the existing structure upon which the new
structure are to be attached are sound with no rot or deterioration and will support all structural loads and
forces imposed on them.By signing below,I hereby declare that I will hold the City of Atlantic Beach
harmless and release it from any responsibility and liability for any adverse consequences or failures
resulting from this work,and further that I will not initiate,execute or enjoin any legal action against the
City of Atlantic Beach for such consequences or failures.
A copy of this document will be recorded as an official record with the Building Inspection
Department permit history so that any and all future buyers/owners of this property may be made
aware of the status of work performed on this structure.
Signed Date / /
Before me this day of
In the County of Duval,State of Florida,has personally appeared
herein by himself/herself and
Affirms all statements and declarations herein are true and accurate.
Notary Public at Large,State of ,County of
Personally Known or Produced Identification
ID Type
F:building/affidavit for attaching a new structure to an existing structure.docx 7/21/09
SUNROOM, SCREEN ENCLOSURE, AND/OR SCREEN ROOM AFFIDAVIT
• CITY OF ATLANTIC BEACH
JOB ADDRESS: PERMIT#
INSPECTION REQUEST PHONE LINE(904)247-5826
The purpose of this document is to make you aware of any limitations in the enclosure that is being permitted at your residence.
The table below, Sunroom and Screen Enclosure Requirements provides a brief description of the various sunroom category
requirements. There may be restrictions on the use of your present home depending on the category of sunroom you are installing.
The property owner is hereby notified that should any form of temperature control system be added to a Category I, II, or III
Sunroom or the removal of the doors separating any Category I thru IV Sunroom from the host structure occur, the room shall
become non-compliant and must comply fully with all of the requirements for habitable/conditioned spaces as mandated by the
Florida Building Code,The Florida Model Energy Code and State Statutes.
Screen Room,Sunroom and Screen Enclosure Requirements
Category I H III IV V
Habitable Space No No No Yes Yes
Foundation Walls<200plf can Walls<200plf can Walls<200plf can Walls<200plf can have Walls<200plf can have
have 8"Wx12"D ftg have 8"Wx12"D ftg have 8"Wx12"D ftg 8"Wx12"D ftg 8"Wx12"D ftg
or 3-1/2" slab if no or 3-1/2"slab if no or 3-1/2"slab if no
concentrated load concentrated load concentrated load
>7501b >7501b >7501b
Exit Lighting Not Required Required Required Required Required
Interior Electric Not Required Not Required Not Required Required Required
Outlets
Emergency EscapeEgress from exist. Egress and Exit must Egress and Exit must Egress and Exit must Egress and Exit must
Openings structure allowed if meet code meet code. Other meet code. Other meet code. Other
open to atmosphere or resistance -esistance requirements resistance requirements
considered screen requirements for for forced entry, air for forced entry,air
enclosure and has forced entry,air leakage and water leakage and water
screen door leading leakage and water penetration also apply. penetration also apply.
away from residence. penetration also apply.
Misc.Window and Host structure Removable windows Removable windows Host structure windows Host structure windows
Door Requirements windows/doors shall allowed in sunroom. allowed in sunroom. Sc doors shall not be &doors may be
not be removed. Host structure Host structure removed. removed.
windows/doors shall windows/doors shall
not be removed. not be removed.
Wind Borne Debris Not Required Not Required Not Required Not Required Not Required
Opening Protection
Energy Sheets Not Required Not Required Not Required Required Required
I hereby acknowledge that I have read and understand all the above on this Day of
Home Owner's Signature Print Name
STATE OF FLORIDA, COUNTY OF DUVAL:
The foregoing instrument was acknowledged before me this day of , 20 ,by
herein by himself/herself and affirms all
statements and declarations herein are true and accurate.
NOTARY PUBLIC, STATE OF FLORIDA
Print Name:
❑ Personally Known/11 Identification:
800 SEMINOLE ROAD,ATLANTIC BEACH,FL 32233 PHONE(904)247-5826 FAX(904)247-5845 REVISED 1-20-10