357 11TH ST - R.O.W. . ' CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
7.5v z
ATLANTIC BEACH, FL 32233
x O;j INSPECTION PHONE LINE 247-5814
RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: ROW17-0029
Description: install 35 ft. wood pole & service drop across street
Estimated Value: 0
Issue Date: 11/29/2017
Expiration Date: 2/27/2018
PROPERTY ADDRESS:
Address: 357 11TH ST
RE Number: 170108 0000
PROPERTY OWNER:
Name:
Address:
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
,
Phone:
Name: JACKSONVILLE ELECTRIC AUTHORITY
Address: 21 CHURCH ST W 3RD FLR
JACKSONVILLE, FL 32202
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
i),A�,�l l„ City of Atlantic Beach APPLICATION NUMBER
rf s9 Building Department (To be assigned by the Building Department.)
-. s 800 Seminole Road k2-0w11-_ DD�C1
iiij Atlantic Beach, Florida 32233-5445 r:
Phone(904)247-5826 Fax(904)247-58 & , ' f �1
art 9'? E-mail: building-dept@coab.us Date routed: I� l I L "-
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: '- t• l S Department review required Yes No
A
Building
Pr
Applicant: I Planning &Zoning
Tree Administrator
Project: t 1\SkCt. vt 3S ,W OQok p6 a- blit
J.10t_
`L L b A 4. aC ` SkNi
jZ C Public Utilities
(OSS ¢ Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING
Reviewed by;..J Date://WIZ
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
�;StAvr,, City of Atlantic Beach APPLICATION NUMBER
�s i' i, Building Department (To be assigned by the Building Department.)
r 800 Seminole Road n O 1-_ CC 1 C,
_ Atlantic Beach, Florida 32233-coab.u5445 `L 1 O�
Phone(904)247-5826 • Fax(904)247-5845 ` t-I'0 i n 2017
��i,�•j?� E-mail: building-dept@coab.us Date routed: II \. 1 to L L "1"
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 3C l } S+ Department review required Yes No
t� Building
Applicant: I A Planning &Zoning
? Tree Administrator
Project: d\SSCt U,l JS .vo00A pi6 ,e or ublic Wo
S j,v.lL L ki..y Cts as,s 1 S ,_ C Public Utilities
Public Safety
Fire Services
Review fee $ 7Dept Signature i-----\"----
Review or Receipt
Other Agency Review or Permit Required of Permit Verified By Date
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: pproved. Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: dea `';14"----- Date: /2j
l
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ['Not applicable
LNCyKS Comments:
UBLIC UTILITIES
//—/7—► 7
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
•
• CITY OF ATLANTIC BEACH • '-'1, 1
r 1.91 CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS
800 Seminole Road 904-247-5800
• !�;,�� Atlantic Beach, Florida 32233-5445 Fax 904-247-5845
PLEASE SUBMIT COMPLETE SETS OF PLANS WITH APPLICATION.
Date /1— / " / PERMIT# Y C'�^ l c-C.
L ISSUED BY THE CITY
Job Address 3s'� h �' S✓
Permitee: TEII Telephone# — 2793
Permittee Address: ?_1 It/'s/ Com► -t Sfl
Requesting Permission to Construct: sr}-t.,G/ ) 3S ael-SS / wBe d P®/P_ i--
Location: (Reference to Cross-Street)
1. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities,
both aerial and underground and the accurate locations are shown on the sketches.
A Letter of Notification was mailed to the following Utilities/Municipalities:
Jacksonville Electric Authority Yes( ) No ( ) Date:
Bell South Telephone Company Yes( ) No ( ) Date:
Ferrell Gas Yes( ) No ( ) Date:
Comcast Yes( ) No ( ) Date:
2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation,
alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public
Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized
hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as
required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is
authorized.
3. All work shall meet City of Atlantic Beach oFlorida Department of Transportation Standards and be
performed under the supervision of �. �PSC�-� (Contractors Project
Superintendent) located at L/ W. Git cr S f-. Telephone#: (��- 7?
4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee.
5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications
and the manner satisfactory to the city.
6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a
part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city
Right of Way are to be included with this application.
7. This permittee shall commence actual construction in good faith with 60 days. If the beginning date is
more than 60 days from date of permit approval, then permittee must review the permit with the Director of
Public Works to make sure no changes have occurred in the area that would affect the permitted construction.
8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the
City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all
times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and
against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted
exercises by the holder of the aforesaid rights and privileges.
9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again
immediately upon completion.
OWNER
Signed: Date:
Before me this day of in the County of Duval, NOV 1 6 2017
State Of Florida, has personally appeared
Notary Public at Large,State of Florida,County of Duval.
My commission expires: Personally Known?---_._
Produced Identification:
a
44*
Fl
+! F
a4.
a
i► l , "� ills ir
ter_ ` , _-
:;
' t au ,` , ' +fin' c' i - ,4
�
,...._, . :-,.:_'" ' .',;:,''11,-.'._. '„,4,,,,,., 4-t,:-'-'.*.,
AF r^"0 A�
;4 q §r, T.
1 :Nli 1
A N A
` .ms �' Q
t \ 11111miont ,.. _.ii 6 Fi ,
a .v .may: I ,r * .r e •
• ,
it
' .
'II,a=
„,. t '. ‘: 1... . .'IF__ '," ' ...x
rr _
s
4
r
• ENGINEERING DESIGN
ORACLE PERMIT MAXIMO DATE REL
PROJECT#: 31469 N.O.: 8004473 WO#: 30193459 CONST: 11117/17
CIR. TREE TRIMMING
SUB-STA: NEPTUNE BEACH N.O.: 563 REQ'D:NO
CELL
ENGINEER: Robert Simpson N.O.: NIA ZIP CODE: N/A
CUSTOMER/ SVC PHONE
LOCATION: 361 11TH ST./POLE INSTALL 563 CENTER: SSSC N.O.:665-7793
MrINIMIIIIIIMI 1 -- ....-....-----...- -
STA 1. P# 361 11TH ST./ INSTALL Zp,L �_�O - U
35/4W, RUN 4/OP TO STA 2 2: • A
' -�
''
STA 2. P#370 11TH ST. •'
*** ***** 1/OT
�,
**
NEW HOME BUILD 1/0T
/
P' . j
J '
352
-d o• !N - 370 360 349 3.
-e. -, 1 0 357 355 3�1 4
' ; 359 • 1
1 4
393 ti
50BSTA 1
o
--, 1 -
= o
1/0T 4/OP
VI 40- �i -4 b
o 1r0O
4 4111. .
1
�
I 11Th S __°``�� _ ----
c72/OP•
w Lri /21OP • v -) oT
o 1
T
...-------•
_ _ -• 2/OP
v T
CD1/0T (-) o
O Ul T
T
• STA2 4 • I 4
392 364 358 354•
3
4 374 PV01 349 3445
0 388 380 369 365 4
--.1
379
lilli
387 •383
o
4
JEA.- CUE Reports
Estimate Number:31469 361 11Th ST 35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC
Estimate Version: By: SIMPRB
MWO#/Task:30193459 Required Date:
Orade Project#:8004473 Estimated On: 11/15/2017
Cost Estimate
Materials JEA Contractor
1.New Material Cost(w/sales tax) $652.10 $652.10
2.Transformer Cost(w/sales tax) $0.00 $0.00
3.Returned Material Salvage Value $0.00 $0.00
Labor
4.Crew Time $273.45 $762.33
5.Extraordinary Costs $0.00 $0.00
JEA Overhead
6.Fringe Benefits(54.56%of lines 4&7) $190.90 $116.25
7.Engineering Costs(Variable%of line 4) $76.43 $213.07
8.Project Equipment Costs(40%of total equipment costs) $157.93 $0.00
9.Material Handling(8.30%of lines 1&2) $54.12 $54.12
10.Inspection(6.84%of line 4) $0.00 $52.14
11.Total Cost of Project $1,404.93 $1,850.02
12.Work Order Estimate(Line 11 minus line 8,9,&10) $1,192.88 $1,795.89
13.Billable Equipment Depreciation(60%of total equipment costs) $236.90 $0.00
14.Billing Estimate(Including Transformer Cost)'(Lines 11+13+(58.71%of 4&7)) $1,847.25 $1,975.11
15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $1,847.25 $1,975.11
Time Estimate
Crew Hours Total Manhours
2.19 8.77
CUE Reports
Estimate Number:31469 361 11TH ST 35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC
Estimate Version: By: SIMPRB
MWO#/Task:30193459 Required Date:
Orade Project#:8004473 Estimated On: 11/15/2017
CU Detail
Station: 01 361 11TH ST.
Build Transfer Remain In Place Remove
C.4/0P 90
G3W 1
G3W*2 1
GY3 1
GY3*5 1
P.35/4W 1
S4 1
S4*4/0 1
Station: 2 370 11TH ST.
Build Transfer Remain in Place Remove
RUBUP 2
S20ES*4/0-4/0 1
S4 1
S4*4/0 1
RUBDOWN 2
CUE Reports
Estimate Number:31469 361 11TH ST 35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC
•
Estimate Version: By: SIMPRB
MWO#/Task:30193459 Required Date:
Oracle Project#:8004473 Estimated On: 11/15/2017
Material Summary
Item Quantity item Number Item Description
2 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZED 10"X 8'X 1-1/4", SHIP
ON OPEN FLATBED ONLY!
2 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
90 CAIOS003 CABLE, 4/0-19 (PAP), OVERHEAD SERVICE DROP, 600 VOLT
MULTIPLEX CABLE "VICKSBURG" PRE-ASSEMBLED PARALLEL 1000
FOOT REELS
2 CLAGROO1 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK"
1 CLASR002 CLAMP, STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI -4/0 PAP
2 CLASS006 CLAMP, STRAIGHT STRAIN, ALUMINUM, 10000# 3/0 -556 ALUM
5 CNNCP002 CONNECTOR, #2, 6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION,
PARALLEL TAP,
3 CNNCP007 CONNECTOR, #7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION,
PARALLEL TAP, ALUMINUM,
4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE
22 COBCO028 CONDUCTOR,#4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON
PLASTIC REEL, 4"X 11.5"W/2" HOLE
140 COBCW014 CONDUCTOR, #4,TYPE 40 DSA, COPPERWELD & COPPERWELD-
COPPER .204"DIAMETER 1480#BREAKING STRENGTH ( 50#COIL-
427' )
2 COVIC002 COVER, "D" DIE, INSULATING, 2-1/2"
2 GUAGW001 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC
2 GUAGW002 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED
ON ALL 3/8"AND 7/16" GUY STRANDS (DISTRIBUTION).
2 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP
GALV. 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT. STRENGTH. FOR
WOOD OR CONCRETE POLES
4 GUYGROO1 GRIP, GUY, 3/8", 26", GALVANIZED
100 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS
"B" GALV. OR BEZINOL IS ACCEPTABLE (500'COIL)
1 INSGB002 INSULATOR, STRAIN, GUY BREAKER, 21,000# RATED, 60" ROD
LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM
ONLY
4 INSS0002 INSULATOR, SUSPENSION, 4", CLASS 52-9 NEMA STRENGTH 10000#,
GALV. FITTINGS
1 POLW0003 POLE, WOOD, 35'CLASS 4 (T/L =44), WEIGHT=1,026 LBS
2 RODGR003 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED
ONLY!
1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK
CHARACTERS((NOT FOR "SLIDE IN" CHARACTERS)). 19.5" HIGH X 2"
WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG.
OF 50 EACH)
2 WASRD005 WASHER, ROUND, 3/4" BOLT SIZE X 2" DIAMETER, GALVANIZED, ***
500 EACH PER BOX ***
2 WASSF003 WASHER, SQUARE FLAT, 3" SQ X 1/4", 5/8"X 3/4" BOLT SIZE,
GALVANIZED
JEA
• CUE Reports
Estimate Number:31469 361 11TH ST 35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC
Estimate Version: By: SIMPRB
MWO#/Task:30193459 Required Date:
Oracle Project#:8004473 Estimated On: 11/15/2017
2 WASSP002 WASHER, SPRING, 3/4" BOLT SIZE, DOUBLE COIL HELICAL TYPE,
GALVANIZED (EXTRA HEAVY DUTY)
" E. CUE Reports
Estimate Number:31469 361 11TH ST 35/4W POLE INSTALL Estimate Type:SR Contractor:HENKELS&MCCOY INC
Estimate Version: By: SIMPRB
MWO#/Task:30193459 Required Date:
Orade Project#:8004473 Estimated On: 11/15/2017
CU Summary
BUILD
CU Name Quantity Description
C.4/OP 90 4/0 AAC PAP W/4/0 AAAC NEUTRAL
G3W*2 1 WOOD POLE -NON-EQUIPMENT GROUND
GY3*5 1 GY3*5 3/8" DOWNGUY W/8 FT SCREW ANCHOR
P.35/4W 1 35 FT. CLASS 4 WOOD POLE
RUBUP 2 LINE RUBBER INSTALLATION, PER SECT.
S20ES*4/0-4/0 1 SECONDARY CONNECTION AT POLE
S4*4/0 2 SECONDARY DEADEND
REMOVE
CU Nam@ Quantity Description
RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT.