2133 1 r•j y„1,f J!v 3 �' , l CITY OF ATLANTIC BEACH '` , 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 X0;3 PV INSPECTION PHONE LINE 247-5814 FOUNDATION ONLY - SINGLE OR TWO FAMILY FOUNDATION ONLY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: FOUN17-0002 Description: foundation repair Estimated Value: 7503.77 Issue Date: 10/12/2017 Expiration Date: 4/10/2018 PROPERTY ADDRESS: Address: 2133 SEMINOLE RD 1 RE Number: 169515 0430 PROPERTY OWNER: Name: COOPER DIANNE Address: 2133-1 SEMINOLE RD ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: ALPHA FOUNDATION SPECIALISTS Address: 4778 - B WO B WOOLAND CIR QA MATTHEW STEPHEN SHANLEY TALLAHASSEE, FL 32303 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. r11.1- City of Atlantic Beach APPLICATION NUMBER t\ Building Department (To be assigned by the Building Department.) r y.1 800 Seminole Road 'l�l.l Ai 11 — 000-e)- -' -e Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 LJ/�I i S ) i oit gr E-mail: building-dept@coab.us Date routed: 6Y City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: a 13 &,i'n,'1 te`.l k It *) De artment review required Yes No qq i �-� B . •.i• rT Applicant: \ ?\( )A �"VU t 0 5 P( i Ll t r Treen Zoning r Project: FOL-tIn a U4 3") f L f ti.i I Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers 0 Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco (U W Other: \ APPLICATION STATUS Reviewing Department First Review: ❑Approved. iti Denied. ❑Not applicable (Circle one.) Comments: 54_4_ (___oINA�,E._A -r✓ 5 ,.,,,,., '4-9 BUILDING PLANNING &ZONING "‘" :, Reviewed by: lDate: `2< <7 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 icJcj ,u, City of Atlantic Beach APPLICATION NUMBER 4S , Building Department (To be assigned by the Building Department.) ,1 ' 1 800 Seminole Road. ,�1 j r� Atlantic Beach, Florda 32233-5445 Li.&i I — ' C.. r� Phone(904)247 5826 Fax(904)247 5845 „01119. E-mail: building-dept@coab.us Date routed: t'�� S ' City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: Q I S-�int n &L 1 f Department review required Yes No 1 �-- B • . i• Applicant: A `A)1` A �l) t d%i to 3:1 s.)e b d tall -lanni Zoning J Tree • . 'nista-tor Project: -Nail t(a-h3.'1 1t?1A t ( Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. ,[1Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by:// "." j��s. Date:' �.3""1 7 TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 I BUILDING PERMIT APPLICATION OFFICE COPY CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach,FL 32233 Office(904)247-5826 Fax(904)247-5845 `' Job Address: 2133 SEMINOLE RD 1 Atlantic Beach FL 32233 Permit Number: i v LA .' 11 -000 Legal Description 09-2S-29E .138 Parcel# 169515-0430 Floor Area of Sq.Ft. Sq.Ft • Valuation of Work$ 7503.77 Proposed Work heated/cooled 1647 non-heated/cooled_ 841 _ Class of Work(circle one): New Addition Alteration 'epair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial CResidentia7D _ If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No " A Florida Product Approval# For multiple products use product approval forst Describe in detail the type of work to be performed: l 6. -t, cinei r- 20 Property Owner Information: Name: Dianne Cooper Address: 2133 SEMINOLE RD 1 City Atlantic Beach Sta a FL Zi I 3223 Phone '' i " • •3 • 1 E-Mail or Fax#(Optional) ......::_'.Tri(miti:_I ' Ali .. r I' is a*. _J ? (Yt P. ' • 001 Contractor Information: Company Name: Alpha Foundation Specialist Qualifying Agent: Matthew Shanley Address: P.O.Box 13469 Tallahassee FL 32317 City Tallahassee State Fr Zip 32317 Office Phone (850)877-1313 Job Site/Contact Number 9 f),.5 —031( Fax# (850)671-1313 _ State Certification/Registration# CBC 125 7350 Architect Name&Phone# Engineer's Name&Phone#Gy1.2,1A ZuSicIVA) g� .. 1 a 1 �%\leX lot I . CO 3cAsf 22_6 T Fee Simple Title Holder Name and Address Eti Bonding Company Name and Address Mortgage Lender Name and Address D'F-ft i-t & P 1 esi• : Ll AA,flu I l • c c)w. Application is hereby made to obtain a permit to do the work and installations indicated I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. r u co null and void tf work is not commenced within six(6)months,or if construction or work is suspended or abandoned for a period of six 1. 1 t;the pi ,17 after work is commenced. I understand that separate permits'must he secured for Electrical Work,Plumbing,Signs, Wells,Poo r, - races, o' Heaters,Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A N 1 7 c, I f COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FO• i' ' : _ .rtment TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCIN t I� . • teach, FL YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO 6 ' COMMENCEMENT. /hereby certify that I have read and examined thisplication and know the same to be true and correct. All provisions of laws and ordinances governin this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the -.1<o 4 F). provisions of any other federal,state,or local law regulating construction or the performance of construction. i 4 Signature of Owner )1"jr Signature of Contractor _ 5 it o` Print Name �in G �'� Print Name "1\L ---• Y yr an a�.�. 4 II us F Sworn tp and subs gibed before e Swo t and subscri d before me 1 -v z o this I spay of 4,l _ _1y 20 this i,Day of t I �1 .20 —1 et A 110 a- T Z 1 H oND ..moi a'1<< �. / ' .A 0 IA A A_ o < Not. PubA . Not.i'uilic 2 ,.� JOYCE CONWAYIIIF Revised 01.26.10 frio , ^ MY COMMISSION#FF921647 EXPIRES:SEP 24,2019 Bonded through 1st State Insurance ..ri I, •' ,„ CITY OF ATLANTIC BEACH w 800 SEMINOLE ROAD +j ' r ATLANTIC BEACH, FL 32233 (904) 247-5800 o\ . BUILDING DEPARTMENT REVIEW COMMENTS Date: 8/21/17 Permit#: FOUN17-0002 Applicant: Alpha Foundation Site Address: 2133 Seminole Road Address: PO Box 13469 Tallahassee Review: 1 Phone: 850-877-1313 RE#: 169515 0430 Email: office@alphafoundation.com THIS BUILDING DEPARTMENT REVIEW IS ONE OF 2 DEPARTMENT REVIEWS. PLEASE FIND ALL DEPARTMENT REVIEWS AND ADDRESS ALL COMMENTS. Correction Comments: Application is disapproved for the following issues: 1. Work was done before building permit was reviewed or issued. Stop Work Order posted. 2. Additional fees due: 100% of original permit fees plus $220.00, per FBC-B, Section 109.4. 3. The foundation and floor slab for all six units was poured together and the foundation and slabs for each unit are connected. Lifting unit 1 may have affected the construction of the adjacent unit 2. FBC-EB, Section 606.2.2.1 requires a structural evaluation by a registered design professional. Please submit a structural evaluation and inspection report for units 1 and 2, including foundations, slabs,walls,framed floor/ceiling assemblies, and roof structure, including the weather resistant capabilities of the roof and exterior walls. The evaluating design professional must arrange access to the units with the building department, in advance. 4. The in-progress foundation repair inspection can be done during the evaluation inspection. All foundation repairs must be open and exposed for inspection. 5. A final inspection will be required Dan Arlington, CBO 904-247-5813 darlington@coab.us 1 r' �,, ,, ,,,,,,,,•tt P *,,,‘, OF ATLANTIC BEACH AR 800 Seminole Road T< Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date (61106017- Revision to Issued Permit Corrections to Comments Permit# Foo N 17 OOO Z Project Address 2133 StA,coaDL6 2,4.0 tnnn-t ' Al tO,„4,r, ie,(„ J.l 3-7.a33 Contractor/Contact Name apL A c11 (1 S r l S 4 ,'- et-i) Phone q-rm- 02- b348 Email Sic6oQa,(,.?(„Air,, ,f';ay..(- .e(AA Description of Proposed Revision/Corrections: Permit Fee Due $ D SG\ (,otli kkYtiviAl %EL,, '2133 -cwvi,n,Wkt Ve, cam- , ,�I. 4-1L c6.nitet,, CI 3a0,33 Additional Increase in Building( Value $ Additional S.F. By signing be Ati' c,J,1 �� affum the Revision is inclusive of the proposed changes. (printed name) C 12 (9-v 1 Signature ofd tractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments 5i-i 6.-o •-•.e4.10_, +y -N---- Department Department Review Required: Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities 110 c ( Cl Public Safety Date Fire Services green building Desijn Engineering Project Management Inspections " - (904)900-5856 1301 Riverplace Boulevard Suite 800 Jacksonville,FL 32207 www.greenbuildingdesign.com Certificate of Authorization Number 28891 Donald A. Boggs, PE Florida PE 31054 don@greenbuildingdesign.com Foundation Stabilization 2133 Seminole Road Unit 1 Atlantic Beach, FL 32233 August 8,2017—August 22, 2017 Revision ti Mr. Shawn Reed 7 Alpha Foundation Specialists, Inc. 4778-B Woodlane Circle Tallahassee, FL 32303 Dear Mr. Reed: I have reviewed the settlement issue at 2133 Seminole Road Unit 1,Atlantic Beach,FL 32233 and have the following comments: 1. The structure is a three-level wood frame condo with a stucco built in 1989. 2. The unit is slab on grade. 3. This condo is the northern most unit in a group of six. 4. The eastern portion of the north wall and the entire east wall has settlement cracks in the stucco. 5. Measurements of the interior floor slab along the east wall indicate settlement to be as much as 3.3 inches below the original finished floor. 6. The cause of the settlement is unknown, but is believed to be poor soil compaction during initial construction. 7. Another possible reason for settlement is decaying tree roots under the foundation. 8. Soil borings were not taken. 9. It is likely that differential settlement will continue to occur unless the foundation is stabilized. Alpha Foundation Specialists, Inc. Foundation Stabilization 2133 Seminole Road Page Two 10. To stabilize the foundation, we recommend installing 3 three inch helical piles along east wall and 1 three inch helical pile at the most eastern part of the north wall for a total of 4 three inch helical piles. These piles are to be up to 14 feet long using standard brackets spaced a maximum of seven feet apart. See attached sketch. 11. To stabilize the interior floor slab, we recommend using Po1yLEVEL as shown on the attached sketch. 12. The foundation and floor slab are only to be stabilized to prevent further settlement. Lifting is not recommended. If you need additional information or have any questions, please call. Respe t y, Do ald A. Boggs, PE FL PE 31054 \11 ti ;/".I green 6Building ®esn ti Engineering ; Project Management ( Inspections (904)900-5856 1301 Riverplace Boulevard Suite 800 Jacksonville,FL 32207 www.greenbu i Id ingdes i gn.com Certificate of Authorization Number 28891 Donald A. Boggs, PE Florida PE 31054 don@greenbuildingdesign.com Foundation Stabilization 2133 Seminole Road Unit 1 Atlantic Beach, FL 32233 August 8, 2017—August 22, 2017 Revision Mr. Shawn Reed /-�ti Alpha Foundation Specialists, Inc. 4778-B Woodlane Circle Tallahassee, FL 32303 Dear Mr. Reed: I have reviewed the settlement issue at 2133 Seminole Road Unit 1,Atlantic Beach,FL 32233 and have the following comments: 1. The structure is a three-level wood frame condo with a stucco built in 1989. 2. The unit is slab on grade. 3. This condo is the northern most unit in a group of six. 4. The eastern portion of the north wall and the entire east wall has settlement cracks in the stucco. 5. Measurements of the interior floor slab along the east wall indicate settlement to be as much as 3.3 inches below the original finished floor. 6. The cause of the settlement is unknown,but is believed to be poor soil compaction during initial construction. 7. Another possible reason for settlement is decaying tree roots under the foundation. 8. Soil borings were not taken. 9. It is likely that differential settlement will continue to occur unless the foundation is stabilized. • Alpha Foundation Specialists, Inc. p Foundation Stabilization 2133 Seminole Road Page Two 10. To stabilize the foundation, we recommend installing 3 three inch helical piles along east wall and 1 three inch helical pile at the most eastern part of the north wall for a total of 4 three inch helical piles. These piles are to be up to 14 feet long using standard brackets spaced a maximum of seven feet apart. See attached sketch. 11. To stabilize the interior floor slab, we recommend using Po1yLEVEL as shown on the attached sketch. 12. The foundation and floor slab are only to be stabilized to prevent further settlement. Lifting is not recommended. If you need additional information or have any questions,please call. Respect lly, D ald A. Boggs, PE FL PE 31054 Doc # 2017190509, OR BK 18088 Page 2153, Number Pages: 1, Recorded 08/15/2017 at 08:25 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 OFFICE COP • Felin v Fav n /"7 - o 0o2- NOTICE OF COMMENCEMENT State of Florida County of Duval Tax Folio No. 169515-0430 To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and:in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT, 'Legal Description of property being_improved: 09-2S-29E .138 PT GOVT LOT 1 RECD O/R 17259-2325 • Address of property being improved. 2133 SEMINOLE RD 1 Atlantic Beach FL 32233 General description of improvements: Foundation Repair 1 • .Owner: Dianne Cooper Address:. 2133 SEMINOLE RD 1Atlantic Beach FL 32233 :Owner's interest hi site of the improvement: Fee Simple Titleholder.(if other than owner): Name: M'.y Contractor: Alpha Foundation Specialist Address: P.O. Box 13469 Tallahassee FL 32317 Telephone No.; (850)877-1313 Fax No: (850)671-1313 Suety(if any) Address: Amount of Bond S Telephone:No: Fax No: Name and:address of any person making a loan for the construction of the itnprovements Name: Address: Phone No: Fax No: Name of person within.the State of Florida,other than himself,designated by owner upon whom noticesor other documents may be served: Name: Address: Telephone No: Fax No: 7'etliliti 13 06 tion to,himself owner designates the following person to receive a copy of the Lienor's Notice as•provided in Section O(b),Florida.Statues. (Fill in at Owners option) Name: Address:, ' Telephone No:. Fax No: Expiration date of Notice of Commencement(theexpiration date is one(1)year from the date of recording.unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNE r Signed: dew 06 0 s 1 iii Before me.this • Date:day of'G� /V=iii the Col ofval,Stale Of Florida;has personally appeared • Notary Public at Large;State Flor.: Co of uva. — ' My Cotrimission expires: {) a4 I ')CJn tt, Personally Known: S Produced Identification: 'FL '� r 1 JOYCE CONWAY E e MV COMMISSION#ff921647 '' EXPIRES:SEP 24,,2019 2019 8 Wed through 1st State Insiurance --- NOTES: 1. MINIMUM MATERIAL REQUIREMENTS: CAP PLATE(HP288C) 1A BRACKET WELDMENT-ASTM A36 AND EXISTING INTEGRATED EXTERNAL SLEEVE - BRACKET HARDWARE iI STRUCTURE Fy=50 ksi, Fu=62 ksi SEE NOTES CAP PLATE-ASTM A572 GRADE 50 BRACKET BRACKET HARDWARE- (HP288 ET Iril (2)-f3/4"x 16"LONG GRADE B7-Fu=125 ksi 2) ALL-THREAD ROD WITH NUTS TEMPORARY liWi Ipi (HWTR-S210-Z-075-16&HWH8N-Z-075) EXCAVATION OPTIONAL BRACKET HARDWARE- (2)-03/4"x 16"LONG AISI 1045-Fu=120 ksi CONTOUR(COIL)THREAD ROD WITH NUTS (HWCR-S250-Z-075-16&HWCN-Z-075) 2.0" 2. ALL WELDING TO BE IN ACCORDANCE WITH AWS D1.1 INTEGRATED Q LATEST ISSUE WITH E70-XX MIN ELECTRODE. EXTERNAL 0 SLEEVE 0 3. BRACKETS AND CAP PLATES ARE AVAILABLE AS EITHER cCw PLAIN STEEL OR HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A123.A"-G"IS ADDED TO THE END OF THE111 HP288 OR HP287 PART NUMBER TO DESIGNATE PART AS HOT-DIP PIER SHAFT GALVANIZED. 4. BRACKET HARDWARE IS PROVIDED AS ELECTROZINC 0 PLATED IN ACCORDANCE WITH ASTM B633. COUPLER 5. THIS DOCUMENT IS MEANT TO SERVE AS A GENERAL PROJECT DETAIL DESCRIPTION FOR THE PRODUCTS SHOWN FOR SUBMITTAL PURPOSES.MORE DETAILED MANUFACTURING DRAWINGS ARE AVAILABLE UPON REQUEST. 1---6.75 • o is an t rA t � � -1 �le '11®IibR LailE4ii — I Jr gi Co Co I 10.50 11111 11111 BRACKET DETAIL Document#: Date: 4/24/15 - FOUNDATION - All dimensions are in AR-H PB R-288-B2SUPPORTWORKS' inches and are for reference only. Assembly- 02-7/8" Helical Pier Bracket12330 Cary Circle,Omaha, NE 68128 scale: 1:10 Revision: 0 Sheet: 1 of 1 Phone: 800-281-8545 DO NOT SCALE DRAWING ©FOUNDATION SUPPORTWORKS®,INC. NOTES: 1. MINIMUM MATERIAL REQUIREMENTS: SHAFTS-Fy=60 ksi,Fu=70 ksi COUPLERS-Fy=70 ksi,Fu=80 ksi HELIX PLATES-ASTM A572 Gr.50 SHAFT COUPLING HARDWARE-(2)-0 3/a" GRADE 8 BOLTS WITH NUTS 2. ALL WELDING TO BE IN ACCORDANCE WITH AWS D1.1 LATEST ISSUE WITH E70-XX MIN ELECTRODE. lik* 02.875 O.D.x 0.203 WALL 3. HELIX PLATES HAVE A NOMINAL 3"PITCH WITH BLANK EXTENSIONS LEADING AND TRAILING EDGES BEING NO MORE THAN Y4" (NO HELIX PLATES) OUT OF PARALLEL. w F, EXTENSION LENGHTS 4. LEADS AND EXTENSIONS ARE AVAILABLE AS EITHER mI m m PART NO. SHAFT OVERALL PLAIN STEEL OR HOT-DIP GALVANIZED IN ACCORDANCE F I-< HP287E2 15.00 23.00 WITH ASTM A123.A"-G"IS ADDED TO THE END OF THE w w HP287E3 30.00 35.00 PART NUMBER TO DESIGNATE PART AS HOT-DIP co rn HP287E4 42.00 47.00 GALVANIZED. I HP287E5 54.00 59.00 'a O HP287E7 78.00 83.00 5. SHAFT COUPLING HARDWARE IS PROVIDED AS z wHP287E0 114.00 119.00 ELECTROZINC PLATED IN ACCORDANCE WITH ASTM B633. W J J LL 6. THE SAME HELIX PLATE CONFIGURATION WITH J = LONGER OR SHORTER SHAFT LENGTHS MAY BE POSSIBLE WITH OTHER COMMONLY STOCKED OR o I C COUPLER CUSTOM FABRICATED PARTS BASED ON THE PROJECT i SPECIFIC REQUIREMENTS. El7. SOME HELIX PLATE CONFIGURATIONS REQUIRE THE USE OF CUSTOM FABRICATED PARTS IN ORDER TO ACHIEVE THE REQUIRED GEOMETRY INCLUDING THE SPACING OF THE HELIX PLATES.THESE CUSTOM PARTS TYPICALLY DO NOT REQUIRE MORE THAN A FEW EXTRA DAYS OF LEAD TIME. 02.875 O.D.x 0.203 WALL 8. THIS DOCUMENT IS MEANT TO SERVE AS A GENERAL 0 LEAD SECTION DESCRIPTION FOR THE PRODUCTS SHOWN FOR co (HP287L7H02-3850) SUBMITTAL PURPOSES.MORE DETAILED MANUFACTURING DRAWINGS ARE AVAILABLE UPON = REQUEST. i- 0 z III 03.50 O.D.x 0.281 Q ? 111 WALL x 6.00 LONG CC 2x00.84THRU 2.00 0 0.38x012.00 • HELIX PLATE 1 • q 2x04"BOLTS 0 , B 1.50 WITH NUTS • (HWS8B-Z-075-425 • 1.50 &HWSJ5N-Z-075) j 2 2.001 2 x 00.84 THRU \N_ 0.38 x 010.00 4.001 HELIX PLATE ASSEMBLY DETAIL (COUPLER) 45° MITER Document#: Date: 4/24/15 AR-H PLE-287-02 SUPPORIWORKS' inches and are for F o u N o A. r i o n� All dimensions are in reference only. Title: Assembly- HP287 Lead and Extensions12330 Cary Circle,Omaha, NE 68128 Scale: NONE Revision: U Sheet: 1 of 1 Phone: 800-281-8545 DO NOT SCALE DRAWING FOUNDATION SUPPORTWORKS®,INC. green 6Building ®esign )•7-- Engineering I Project Management Inspections (904)900-5856 1301 Riverplace Boulevard Suite 800 Jacksonville,FL 32207 www.greenbui Id ingdesign.com Certificate of Authorization Number 28891 Donald A. Boggs, PE Florida PE 31054 don@a,greenbuildingdesign.com Foundation Stabilization 2133 Seminole Road Unit 1 Atlantic Beach, FL 32233 August 8, 2017 n Mr. Shawn Reed Alpha Foundation Specialists, Inc. i ox 4778-B Woodlane Circle Cad Tallahassee, FL 32303 kQ Dear Mr. Reed: � S I have reviewed the settlement issue at 2133 Seminole Road Unit 1,Atlantic Beach,FL 32233 and have the following comments: 1. The structure is a three-level wood frame condo with a stucco built in 1989. 2. The unit is slab on grade. 3. This condo is the northern most unit in a group of six. 4. The eastern portion of the north wall and the entire east wall has settlement cracks in the stucco. 5. Measurements of the interior floor slab along the east wall indicate settlement to be as much as 3.3 inches below the original finished floor. 6. The cause of the settlement is unknown, but is believed to be poor soil compaction during initial construction. 7. Another possible reason for settlement is decaying tree roots under the foundation. 8. Soil borings were not taken. 9. It is likely that differential settlement will continue to occur unless the foundation is stabilized. Alpha Foundation Specialists, Inc. Foundation Stabilization 2133 Seminole Road Page Two 10. To lift and stabilize the foundation, we recommend installing 3 three inch helical piles along east wall and 1 three inch helical pile at the most eastern part of the north wall for a total of 4 three inch helical piles. These piles are to be up to 14 feet long using standard brackets spaced a maximum of seven feet apart. See attached sketch. 11. To lift and stabilize the interior floor slab, we recommend using Po1yLEVEL as shown on the attached sketch. If you need additional information or have any questions, please call. Respect', ly, t D c nald A. Boggs, PE FL PE 31054 -.1qU/U green quilding ®esiqn Engineering I Project Management I Inspections (904)900-5856 1301 Riverplace Boulevard Suite 800 Jacksonville, FL 32207 www.greenbuildingdesign.com Certificate of Authorization Number 28891 Donald A. Boggs, PE Florida PE 31054 don )greenbuildingdesign.com Foundation Stabilization 2133 Seminole Road Unit 1 Atlantic Beach, FL 32233 August 8, 2017 PORCH • 0 0 cv 4'PF< F< A O L 1)4 40 40A F< `Fl < GARAGE PORCH %;() �\ 0 3" Helical Piles x up to 14 feet long (4 Required) Maximum Spacing is 7'-0" Shaded area to be lifted and leveled using PoIyLEVEL ► , green q3uildin9 ®esIgn ` Engineering ; Project Management 1 Inspections g g 1 (904)900-5856 1301 Riverplace Boulevard Suite 800 Jacksonville, FL 32207 www.greenbuildingdesign.com Certificate of Authorization Number 28891 Photos — 2133 Seminole Road Unit 1, Atlantic Beach, FL 32233 {� 11841 '' �` n �, a 4 9 �` t•� ,-*' t; w3 *,`` y ` ,a1 's rt a Li A -6,- r' 'pC t �Y tiii t f �' 4•2)%t:.• � ` ! ;Y i ,alp '�v�1 s � i t"+ i `, ✓ �� ` ..,..:.A� =, - _ "1 $, }'L-1/1. V `. '� ` ' Mia ' �, • i , l} ,�S M4.ialitt • - ' ' "47,;(;:, Y j *i.;', '* 41► i t � 'L' 'v� y 4-7 6` ' 4 . WJc h Front of the building looking east—far left is Unit 1. 1 r. CD .. 3 ., . m >, -^. 0 jt. _ O 4 .,e+.` V Rei `r . :*': jl- 4.. - ' trio ..._, % 1.. I wo►' • ..: I. r c t `" r ,d.- ► 4n. p"_tie- '. ,R 't• _ .• " vt .yam• t� +' - . ,y Recent Aerial—Far north unit is Unit 1 -0 m- 0 •-1. 0 v, , I KlY1,011 Rd NJ c7.) y Villas Ln N LA) SEMINOLE RD CD 3 = ,,.. 0 (D po 0 cu 24 111 29 2132 00 19.00 _ 11., C We: YL ' 4,. ''.. k..,,,,.., -e, 5 x x (7) < 3 Fi 11,1,1,L D ro Nc' /". es, G.' a) • , IZA4 '.-' t Al •.. 1...) .•. ,-3° F. . w .I. C.') c :.... ..,.. .2. - Cr2 !Si Cr ', . ,..... „., li ! ....) 4 Iv i 1 I ..„...i i --- -7r-Ed. *LIPO'S I a '4- L-- -----'---r7—"--u - ,,,-1------ 01 ....°1119;1101111Fr eie_s., ry v.) Photos—2133 Seminole Road Unit 1 4- ..,...„____, g , ___., _ _ g .,_______, „__,__ ,,, ,_____=_., g _, _1,... .cm.g... . s _.._____.., 1_4 =___,_ ,_ _. =: 1,.,,,,r., _ , ..,,,_____ , ___, ,,,, .____7______,__ _„:,.„, ..; t ,=9! ii 1 ' d t[--- J . .. m i g ,, ltp r Over 3 inches of settlement on this east wall. _ . , _ 1, 4. v 1." .M'" , T r .a .tet.'• '" _ .. =:. ir �V 1 h• \ t 5- a / Alt 4 a' a ` 9.' 1 4 } 'a1 Settlement crack in the stucco on the eastern most portion of the north wall. \ i