Loading...
234 OCEAN BLVD - WINDOWS i'� , y r i M c). '� ' ,-V„'1; CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD . ATLANTIC BEACH,FL 32233 �� ls 1.)' INSPECTION PHONE LINE 247-5814 RESIDENTIAL -ALTERATION RESIDENTIAL MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0287 Description: REPLACE 14 WINDOWS Estimated Value: 7288 Issue Date: 12/6/2017 Expiration Date: 6/4/2018 PROPERTY ADDRESS: Address: 234 OCEAN BLVD RE Number: 170197 0100 PROPERTY OWNER: Name: GAUSLOW NORMAN D Address: 234 OCEAN BLVD ATLANTIC BEACH, FL 32233-5226 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: AMERICAN WINDOW PRODUCTS Address: 2633 S POWERS AVE QA KEITH ALAN GURR . JACKSONVILLE, FL 32207 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. ,eau City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the.Bwltlmg Department), 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 4,4 'r}t1,1� .- E-mail: building-dept@coab.us Date routed l l , City web-site: http://www.coab.us " — APPLICATION REVIEW AND TRACKING FORM Property Address: L._ 4 DO_GANY a LV __Dep_ ent review required Yes No Building? Applicant: NtM.G2l C'•¢�i' V V f NO0 LA Planning&Zoning �I Tree Administrator Project: ) ` . \pJ ( {� © Public Works Public Utilities Public Safety Fire.Services sReview fee $..°. Dept3Signature, Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By _ Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. ['Denied. ❑Not applicable (Circle one.) Comments: `�$.UILDIN' PLANNING &ZONINGReviewed by: Date:`-3a�? TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. ❑Denied. Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 r.� Building Permit Application City of Atlantic Beach OFFICE COPY ".$ 800 Seminole Road,Atlantic Beach, FL 32233 })", Phone: (904)247-5826 Fax: (904)247-5845 Job Address: 031-1 OCeAVC1. Permit Number: R E. 17 22 87 Legal Description 1(a—c,�S 1:27P. ' +) -c:D I?)IK act RE# non-1-o! 00 Valuation of Work(Replacement Cost)$1 eg 88 Pc) Heated/Cooled SF ►Nt 1—fir Non-Heated/Cooled M • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window'Door • Use of existing/proposed structure(s)(Circle one): Commerciali $1/ • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Florida Product Approval# -1*'r J . for multiple products use product approval form Propen Owner Information ' Name: Address: cgsqC ) V*162. Cit .0State 'FL Zip :�L c3S Phone ( =0-711 E-Mail - Owner or Agent(If Agent, Power Attorney or Agency Letter Required) Contractor Information PRODUCTS,INC. Name of Company: 2833 POWERS AVE. Qualifying Agent: Guff' Address ' KSONVILlE,FL 32P07 City State Zip Office Phon 1 I—. . Job Site/ContactAkmber State Certifica ion/Registration • �� • • • ) E-MailENEC AtfB(1Cs9A1.3i Qr� 'a( .(nCle) Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.I (Signatur of Owner or Agent including Contractor) (Signature of Contractor) n Signed and sworn to(or affirm-s)before me this c' day of Signed a d sworn to(or affirmed)before me this i-t day of .Q1_,by/'( <, G J itCgOn by 6041 Gum ..� C.'EG2% o,*4i ture of N.wARDT (Signature of Notary) • MY COMMISSION#GG 000431 ,tr;`;. EVANGELIE CLARKE * * Commission#GG 102835 VA. ura' a EXPIRES:Arre8.2020 * . i_ * 1 OFFt��\o BondedThru BudgetNotarySemces -•` co,' °�n�r...`:.o� Expires May 9,2021 [ rsonally Known OR [t ersonally Known OR 14'oFF�° Bonded TtouBudget Notary Mess Produced Identification [[ ]Produced Identification Type of Identification: IMO 3 yj1L " — - Type of Identification: OFFICECOPY 11—PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 1� Project Name: Ocr) e'- �A Permit # gEs /7 -098'7 Project Address:(95 CCr) @j` i.)e FL„ .3 3 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide .roduct approval may be obtained at:www.floridabuildin•.or. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E A.EXTERIOR DOORS 1.Swinging �...‘ 2.Sliding • 3.Sectional 1, 4.Roll up 5.Automatic 6.Other B.WINDOWS --- - _ . _ 1.Single hung e 1\S fl,L]'7 i LI(001-1o 3 2.Horizontal slider + .� .a r� 144 10. S 3.Casement 4.Double hung 5.Fixed 6.Awning 7.Pass-through 8.Projected 9.Mullion 10.Wind breaker • . 11.Dual action ' 1 2.Other o 1 Category/Subcategory Manufacturer Product Description _., no Use State# Local# H.NEW EXTERIOR N ENVELOPE PRODUCTS 1. 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge.I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. o (Contractor Name) (Print Name) v G o® (Signature) Company Name: AMERICAN WINDOW PRODUCTS,INC. Mailing Address: 2633 POWERS AVE. JACKSONVILLE,FL 32207 City: r� State: Zip Code: Telephone Number:(O 4)13 I a QD 1 Fax Number:(C,Oq) 3 —8 a 44 Cell Phone Number.( ) E-mail Address:ev EC.t m Cry ctt n Com➢ OFFICE COPY itL-Elt : OF ettIVE A 7 EN 2I: L r /� 7 ((PREPARE 1N OUPLUCATE) Permit No. Y2 `2"Od-ff`/ Tax Folio No.1.1® ci 1-01 00 State of County of c)u' k To whom it may concern: - � The undersigned hereby informs you that improveml ent will be made to certain rerol —� n accordance with Section 713 of the Florida Statutes.the following information is stated in this NOTICEperty.and OF • L 1.descripti n of property being improvs414: 9(40 - S @ -! 0 �.! +;IC- r) cam---a 1,0 . A. res.of property bein.improved- 03 4 \.1e`� -41 i ,k Jd . -..i. an-telt . ,... . R R . 0 General descriptio},of improvements: N 4'{ j^'j liSCerc Windo'uS- �o Si . -"I Owner &sWJ / • low(4. ti Address .. ei � i:� l is a. a Owners interest in site of the improvement N/A Fee Simple T rileholder(if other than owner)N/A Name N/A Address WAOFFICE COPY . . (Contactor AMERICAN WINDOWPRODUCTS,INC. Address 2633 POWERS AVENUE-JACKSONVILLE,FL 32207 Phone No.so4-7312247 Fa No. 904-731-8824 Surety(if any) N/A ' Address NiA Amount of bond$N/A Phone No. NIA Fax No. N/A Name and address of any person making a loan for the construction of the improvements. Name N/A Address N/A Phone No_ N/A Fax No. N/A • Name of person within the State of Florida.other than himself.designated by owner upon whom notices or other documents may be served: Name N/A Address N/A Phone No. N/A Fax No.N/A In addition to himself.owner designates the following person to receive a copy of the Lienors Notice as provided in Section 713.06(2)(b).Florida Statutes.(Fill in at Owners option). Name N/A Address N/A Phone No. N/A Fax No. NIA ' Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified}: THIS SPACE FOR RECORDER'S USE ONLY /•WHER Sinned: i hvi . -% •_<.....,...,...,-ear_ Doi_ �9 /7 Before me. s L of -, f �appea fie. Be 1.D71. f. is -d rt- 9 . l' r ; r / i, herein by (.0, F S herseff and times the all statements and d s herein Doc#.2017268423,OR BK 18195 Page 908, ' are hue and accurate -P. A RYANALWARDT Number Pages:1 %,* MY COMMISSION#GG 000431 Recorded 11/21/2017 11:27 AM, ►l + " "'E5:J1ioe 8,2020 RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL • ' --00111110 0 p. 0 ,Bond¢dThNBudoeMtaryServices COUNTY 1 Naari Lsm.:.state of ? . Cou ty or ' 7 !fJi , RECORDING $10.00 r.ymmnitssionexpires: Pets ly Knownor Produced rdentfrcetdor 4zie0--�zy-y6 -zxs--o if ii ______ iiii_ PERMIT ii COPY V, OFFICE COPY �1/431 � °kms 70 —4 „sc.< , ,. ,_...__ ,,,, ., ,_ v...„ . -4\ 4._ ,>,....., s< , , ,,,, .„ _ , .... .. , ,t, " „,,, Q, , 4„,,,,, ....„..,., Q., ,st:, ,...7— (0'1 'N.Z.: %...7:: tC k`P 9— N PERMIT COPY Florida Building Code Online https://tlorldabulldmg.orgipripr_app_au.aspx:palaiu—wvr,vt wu-i... d° „, z ,' „, ,,I.,,,„?:..f .4z, , x� +.e 9 ' ,�a�fFr & AT T ”,w,tea s wio'4, ' `7 ._. s. 5. I : ; i ° s i r y� � , ; a044" PERMIT . 4 : t ;* 4 tf:1r; t. 4 7 err, . COPY �. f r'Oi P BCIS..„.,,,,, Home ? Log In User Registration Hot Topics ; Submit Surcharge ; Stats&Facts ., Publications ` FBC Staff BCIS Site Map Links Search dFlorida .. ' , Product Approval ' t „ USER:Public User product Apnroval Menu>Product or Application Search>Aoolication List>Application Detail s.,',,,; k FL# FL14604-R5 'm' m sti Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext 4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Timothy J. Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers, FL 33913 (800)432-2204 Ext 4314 thoard@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA 506 2006 AAMA 506 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2005 ANSI/AAMA/NWWDA 101/I.S.2 1997 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2005 ASTM E1996 2002 ASTM E1996 2006 1 of 4 11/8/2017,2:25 V Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx`?param=wCiE V XQwtll... i ' TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/25/2017 Date Validated 02/03/2017 Date Pending FBC Approval Date Approved 02/06/2017 Summary of Products i 1 I FL# I Model, Number or Name ;Description i 14604.1 Series 1000 Non-Impact Aluminum I Series 1000 Non-Impact Aluminum SH i SH I 1 Limits of Use 1 Certification Agency Certificate IApproved for use in HVHZ: No I FL14604 R5 C CAC N1006177.01-R4-signed.pdf Approved for use outside HVHZ:Yes i FL14604 R5 C CAC NI006177.02-R2-sianed.pdf Impact Resistant: No ;Quality Assurance Contract Expiration Date Design Pressure: +45/-45 106/30/2020 Other: I Installation Instructions FL14604 R5 II 08-02477.pdf ' Verified By: Luis R. Lomas, P.E. 62514 i Created by Independent Third Party: Yes I Evaluation Reports I FL14604 R5 AE 513233.pdf ! Created by Independent Third Party: Yes ; 14604.2 1 Series 1431 Non-Impact Vinyl SH I Series 1431 Non-Impact Vinyl SH Nailing Fin i Nailing Fin Limits of Use 1 Certification Agency Certificate Approved for use in HVHZ: No FL14604 R5 C CAC NI010607-R2-signed.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 1 12/31/2019 Design Pressure: +50/-50 I Installation Instructions Other: Configuration: O/X Vent Size: W-44.38" H-35" i FL14604 R5 II 08-00556B.odf Glazing: 3/4"Overall I.G. I Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604 R5 AE 510945.odf Created by Independent Third Party: Yes --> 14604.3 1 Series 1441 Non-Impact Vinyl SH I Series 1441 Non-Impact Vinyl SH Flange I Flange Limits of Use ;Certification Agency Certificate Approved for use in HVHZ: No FL14604 R5 C CAC NI010813 R2 sianed.odf 1 Approved for use outside HVHZ:Yes I Quality Assurance Contract Expiration Date I Impact Resistant: No 04/30/2020 Design Pressure: +50/-50 iInstallation Instructions 1 Other:Configuration: O/X Vent Size: W-50.38" H-35.13" i FL14604 R5 II 08-00558B.pdf Glazing: 3/4"Overall I.G. I Verified By: Luis R. Lomas, P.E. Florida P.E. 61514 I Created by Independent Third Party: Yes fEvaluation Reports I FL14604 R5 AE 510947A.pdf ! Created by Independent Third Party: Yes s 14604.4 I Series 2451 Impact Vinyl SH Nailing I Series 2451 Impact Vinyl SH Nailing Fin I Fin j 2 of 4 11/8/2017,2:25 V Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQWtD... Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14604 R5 C CAC NI012533-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/28/2022 Design Pressure: +50/-50 Installation Instructions Other: Configuration: O/X Max. Frame Size: W-48" H-72" FL14604 R5 II 08-00562B.pdf Max.Vent Size: W-44.25" H-35"Glazing: 3/4"Overall Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Laminated IG Created by Independent Third Party: Yes Evaluation Reports FL14604 R5 AE 510951.pdf FL14604 R5 AE NOA Saflex PVB 15-1201.11.pdf Created by Independent Third Party: Yes • 14604.5 Series 2451 Impact Vinyl SH Nailing Series 2451 Impact Vinyl 511 Nailing Fin Fin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14604 R5 C CAC NI013364.02.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/30/2018 Design Pressure: +50/-50 Installation Instructions Other:Configuration: O/X Max. Frame Size: W-48"H-72" FL14604 R5 II 08-02914.pdf Glazing: 3/4"Overall Laminated IG Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604 R5 AE 513739.pdf Created by Independent Third Party: Yes 14604.6 Series 2461 Impact Vinyl SH Flange Series 2461 Impact Vinyl 51-1 Flange Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14604 R5 C CAC NI013364.03.i df Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/30/2018 Design Pressure: +50/-50 Installation Instructions Other:O/X Max. Frame Size: W-53 1/8" H-72"Glazing: FL14604 R5 II 08-02915.pdf 3/4"Overall Laminated IG Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604 R5 AE 513740.pdf Created by Independent Third Party: Yes 14604.7 Series 2461 Impact Vinyl SH Flange Series 2461 Impact Vinyl SH Flange Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14604 R5 C CAC NI012533.01-R3.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/28/2022 Design Pressure: +50/-50 Installation Instructions Other: Configuration: O/X Vent Size: W-51" H-34.5" FL14604 R5 II 08-00564B.pdf Glazing: 3/4"Overall Laminated IG Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604 R5 AE 510953A.pdf FL14604 R5 AE NOA Saflex PVB 15-1201.11.pdf Created by Independent Third Party: Yes 14604.8 Series FWI 1000 Impact Aluminum Series FWI 1000 Impact Aluminum SH SH Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14604 R5 C CAC NI009020.01-R2-sioned.pdf Approved for use outside HVHZ:Yes FL14604 R5 C CAC NI009020.02-R1-sipned.pdf Impact Resistant:Yes FL14604 R5 C CAC NI009020.03-R2-signed.adf Design Pressure: N/A FL14604 R5 C CAC NI010670.01-R1.pdf Other: See drawing 08-02476 for design pressures. FL14604 R5 C CAC NI010670-R1-sianed.pdf Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL14604 R5 II 08-02476.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604 R5 AE 513232.pdf FL14604 R5 AE NOA 14-0423.16.PDF FL14604 R5 AE NOA Saflex PVB 15-1201.11.pdf 3 of 4 11/8/2017,2:25 P Florida Building Code Online https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGBVXQwtll... Created by Independent Third Party: Yes Back :Next: Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: ,111A tiljd • Credit Card Safe sectintlm:;tEI:Et'cs 4 of 4 11/8/2017,2:25 P: J► RCv6'ONS RE'-----_----- DESCRIPTION --- DATE APPROVED A MANUFACTURER'S NAME CHANGE 03/04/09 R.L. B I REVISED PER NEW CERTIFICATION 08/20/141R.L. --- NOTES: 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCCINS WITH SUFFICIENT LENGTH 1. EHE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO 041r WITH TO ACHIEVE A 1 I/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MI•HIUM EDGE REOUIREMENTS OF THE FLORIDA BUILDING CODE. D'STANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. 1NO00 FRAMING AND MASONRY °RENTING TO BE DESIGNED AND ANCHORED 10 PROPERLY i G. FOR ANCHORING INTO METAL STRUCTURE USE #10 Slvl= OR SELF DRILLING SCREWS 1'JFTH. TRANSFER ALL LOADS TO STRUCTURE. FRAMI,IG AFID MASONRY C'FEi''I NG IS THF S UFFI TENT LENGTH TO A..CHIEVE 3 THPEADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. RESPONSIBILITYOF THE ARCHITECT OR EINGINEEP OF RECORD. LhTI ATE AIICHORS AS SHOWN IN ELEVATI?NS. AND INSTALLATION DETAILS. 3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 17. ALL FASTENERS 'TO BE CORROSION RESISTANT. WHERE SHIM OR BUCK THICK NESS IS LES'.. THAN 1-1/2" WINDOW UNITS L'U;:,T BE 18. INSTALLATICI�I AlICHOFS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR . ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INISTRUCTIOLNS AND ANCHORS SHALL. NOT BE USED IN ITISTALLATION INSTRUCTIONS.IJCTIONS. AI I HORS SHALL RE SECURELY FASTENED DIRECTE.1 I14TC' SUBSTRATES WITH STREIM1IGTHS LESS THAM THE MINIMUM STRENGTH SPECIFIED BELOW: MASONRY. CONCRETE GR OTHER STRUCTURAL SUBSTRATE MATERIAL. A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0=0.42 5. WHERE '.ROOD BUCK THICKNESS IS I 1/2" OR GREATER, BUCK SHALL BE _•CrLIREL. B. CONCRETE - iv1LN11vIUl:' COMPRESSIVE STRENGTH I CF 3,192 PSI. FASTENED TO MFSCNPI, C!--'1`I',;PLTF OR OTHER S TPUCTURAL SUBSTRATE. WINDOW UN1T'S 1v1AY C. IvIASOF!R'/ - STRENGTH CONFORMANCE HN;.E TU ASTM: C 90RADE IN, TYPE ' NOR GREATER). BE ANCHORED THROUGH FRAME TO SECURED WEED BILCI• !,1 5C,'TORDANCE WITH 0. METAL STRUCTURE: STEEL 18C A. 331'51 OR ALUMINUM EO.3-T5 1/8" THICK MIN'v:IR.I MANLIFACTURER•S PUBLISHED INSTALLATION INSTRUCTIONS. 13. WHERE: IX BUCK IS, 1101 USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FLM FRAME SUPPORT IS PRO4 FCGI FIN ND. ' INSTALL i111A AS NEEDED. FOR FRAME II TALI?TI(I� SHIM AS RE:GIIhf.D AT LA-.i ANCHOR LUCAFI 'N WITH LOAD BEARING SHIM, SHIM WHERE SPACE (,r I/113 OR GREATER UCCUPS. MAXIMUM ALLOWABLE SHIM STACK TO BE i/4". .. SHI'.AS SHALL. BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 1 I. FRAME MATERIAL: F.NTRU'DED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REOUIRE_D F!;'R THIS PRODUCT IN IN!ND BURNE DEBRIS REGIONS.. 11. FOR ANC HORIi'lO INTO WOOD FRAMING OR 2X BUCK „-E #iC WOC'D SCREWS 'INI'Fii SUFFICIENT LENGTH TO ACHIEVE A I 3/8' MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:08/21/2014 EASTERNARCHITECTURALMETAL SVLSYS}RAS \�11 III/' / ��I,Iw +`Eastern F/STEP MET!'L SYPRv `\\ R ��iii Si,,M' pn.,..u,.,,....iw�...n v,Nva. 10030 O BAVARIA AVEA UiO :.��••\GEN•S 9(PrSi —-- --- SERIES 1 441 VINYL SINGLE HUNG ,^�'t*. IOr812� i4 TABLE.-. OF CONTENTS 54 X 72 — - SLiF'Ei HC DESCRIF'T'UI NOTES O•. TAT OF :47:-.... I NOTES REI' ��'nE`S.lOR10?'�� �� 2 ELEVATION --— -- A.M 08-00558 B ��ids�ONAI I �\\�� 3 - 5 INSTALLATION DETAILS --- --- — SCALE HIS LATE 7/29/08 I 1 OF 5 l Nir REVISIONS REV DESCR.IPVVOV DATE I APPROVED A - MANUFACTURER'S NAME CHANGE --- 03/04/09 I R.L. - 53 1/2" MAX. FRAME WIDTH— ---- -- 1 B REVISED PER NEW CERTIFICADO�d 02/20,%tq 1R.L. 6'� MA;{. r— (� _ 4" —�— 6" MAX. MAX. O.C. I —r[ ----——_____ _7.1 i .i.-- 1 —I t- il r I . ---- FRAME IIEICH r 1 I Ia1A, 11 ii.L.i:. 4 4 U MAX. ----------- -- --------- 1f ---1- [-- 43 1/2" MAX. D.L.O. — —'i SERIES 1441 VINYL SINGLE HUNG WINDOW EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING ±50.0PSF ! NONE /N' EASTERN MCIIRECTURIL SYSTEMSI j11III/I �• Er osive'!_ EASTERN MMON.S V 0\C �. (O�� ,ai_..:VeVe.M ",l n,�;,En- 5,F.VYEfl5,Fl.0.DAll913 •`v• \GEN •'9�{3�'` 4g===211 10010 BAVARIA ROAD ...-: 1-...us ^ BP1�l1-420+ = -6'4' • SERIES 1441 VINYL SINGLE HUNG .5 •.*- ELEVATION .p� STAT OF teles R DRAV;t:. DWG 50. REV �:'0:ts 4ORIGP'G, •� A.M 08-00558 6 ///s O�JAI SCV. SCALE NTS DATE- 7/29/08 I'"EE'2 OF 5 �/h1!flh1111\`\ lir REVISIONS 1/L" MIN. — !h!. RC- i I _ OESCR,P:10'1 —__- DATE APPROVED 1EDGE DISTANCE II A MANUFACTURER'S NAME CHANCE 03/04/09 R.L. v,./00D"jD FRAMING -� t �I 1 B REVISED PER NEW CERTIRG'QION 08/20/14 R.L. R 2X BUCK \ i i--- I Di OTHERS ti -� 1 3/8" MIN. j— EMBEDMENT -- I n Ir BACKER ROD -.� - JL --_� E& APPROVED ===t= r 1 `1.. I''A; SEA LAkir �� - SPACEHIM 11-1T-71-1 •� i , .1.1 4 =r RE?Td I 3/0.. Hip.!. I-.- .I/'4" MAX. `,l' 1 lit O. EMBEDMENT S,F l, SPACE INTERIOR 11 2.' LAIN. 1 i J 1 � f 1EDGE DISTANCE 1 ( j -1' -{ \ 111 $ \I, fji11 _J, -1--,,- ---;f1(,4 fT"L-. __RE'al I __� — ------ _ ;JIBl(J INTERIOR % \ ( � I <� ' I-! -- it OP ;_'ri BUCK — „...1___.,,j/-- -11 EXTERIOR ` \_ BAC EP ROD & APPROVED EXTERIOR SEALAN I' JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION I j li —J1 7 - -- if!0 WOOD (4, - 4 01 SCPcA0 BACKER RcsD - r''I Le;t,5i:.�_Iu ” ha4t. APPROVED 4, ,j1 — �'I�I I - SE.AIANT 11----'3--11:711-'w= GJ 1� —i S HIm SPACE {- it I WOOD FRAMING —, - _ I 1 ; 3/8' MIN. Bi OTHERSI EMBEDMENT EASTERN A(li.NRECTURAE SYSTEMS X111.111/! VERTICAL CROSS SECTION �'�� Eastern EAS, METAL WRY \\\ R. 1017//i WOOD FRAMING OR 2X BUCK INSTALLATION T00]o SAVARw no. �,� �9 / ,A..:"":i.T:w,n,i: n FORT AIYERS FLORIDA 13913 `�,�.�\O ENs�.d]•/` ..n n..�. �..n�n 800-1]]-2101 • SERIES 1 441 VINYL SINGLE HUNG .`•*t' 0 5)/ * 54 X 72 ,fl sultil(( tt� rLe` NOTES: INSTALLATION DETAILS '�q0 STAT OF tu-- 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. i94 .•A P�• � 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DRAWS OWE.NO REV /..(Is Z ORIO. \`'� DESIGNED INACCORDANCE WITH ASTM E21 12 A.M 08-00558 B ////s/OIVAt•Q.\��� SCALE NTS DATE 7�29�08 ISHEET3 OF 5 '/1111I1T1 lir REVISIONS RE`/ DESCRrPT;CN -_.— --_-�—DATE 1 APPROVED--- METAL -- A MANUFACTURER'S NAME CHANGE 1 03/04/08 N.E. STRUCTURE B REVIFEO PER NEW CERTIFICATION 08/20/14 R.L. BY OTHERS + MAX.. L--I--- — — -I -- -- SHIM SPACE APPROVED ----"--- r�L_—_1 . ` 1 SEALANT \I IT. 1/4." MAT r/ 1I 1T -� r -PACE SHIM 1.S'L,` i I INTERIOR 1-' X10 SMS OR -I--------- �. > 41 T. J SELF DRILLIUO 3/8' MIN. / �— SCREW EDGE DI'SiAb10E. 11 !c,,___,11--11;, -- -1 1-----tiinI ik 5,1 -`�j 0rLU I i, # 0 SUS OR f 1!I! L_JL SELF • DRILLING •�:i I }I L__ 1�ir 1 �_ SCREWS I� _-� 1�ilft nnt''�- _ II �� 1-- t; nAEiaL _ —_L STf;'r.1CTURE _ -:, U1CJ! �� EXTERIOR Lr1 INTERIOR.,�.IJ —�J BY OTHERS �,\ tU�t EXTERIOR I \- BACKER ROD >✓1.,. & APPROVED' F=1 SEALANT4 i ( JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION 1 1 y � - #I0SUE, OR �...F-1,-f-U1 1 SELF DRILLING BACEER ROD _ : :.'� .J &. APPROVED R=�1k_L �_' -1-'---- SEAL r, �1�— 1" MAX. [�I� J`—JS L ; SHIM SPACE • METALS rr..: _ :.�:'<l STRUCTURE ,11] Br OTHEP`.i 11 VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION /�Ip� /��p SADISM ARCRITECIURN SYSTEMS 1111III /rO,� MUM ON OF flS1EMNION SIT`PLY �\\C n. LO��/�i/ 100.30 BAVARIA ROAD \a J (.C ♦/(�9 g ^. A�:nx wxliM A A Yi.'W.e' FORT MYERS,FIORIDA 53910 =v..\•\G E N s�:..O.Vi ..x.: .. .. 500 FitI1 SERIES 1441 VINYL SINGLE HUNG =*• 0,.86 *-- NOTES: 54 X 72 7...."13 �� 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, INSTALLATION DETAILS "�0SS TAT OF �� NOT SHOWN FOR CLARITY. ..;;RI':*<0.•A� P.� 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DHAY:N: Dv/c, o REV / ORIS.G\ 1\ DESIGNED IN ACCORDANCE WITH ASTM E2112 A.M 08-00558 B ��i0SZONA4,_�\�\\ SCALE NTS IDA'E 7/29/08 I<_0EET4 OF 5 u11I111111 AlkT • `-. -.—_---__----.REVISIONS 2 I/2" AIN. RA -- DESCRIPTION `-- V DATE APPROVED EDGE DISTANCE — A. MANUFACTURER'S NAME CHANGE 03/04/09 R.L. CONCRETE/MASON PY -• B REVISED PER NEW CERTIFICAlION 0.,/ZO/1i R.L. Bl' OTHERS �j', -- J - '�j---- ---r -- �------� � I 1/?" ?v1IN. o PTIoNAL I:•: BJCL; ' , , —i. ., — EMBEDMENT SEE NOTES 7 i -0" L11 P . - ' EABEUIdEI SHEET !` .. — _-- -� _ ! 1 _—__— — 1 ;pfJCRETE/1,1AS0NP..1 �.-._._l (� -==,t.�-'-T._1� I;a" tit.ai;. _F By ETHERS { 1.1, BACKER ROD /LJ-J_----_,_-_,..,_-----,--_-.•-. -1..,_� SHIM SPACE 'f` 1 V_ I 4" MAT. & APPROVED LPTIDI. l i:. BUCK - ') o I S•IIM SPACE SEALANT r;7 k� SEE NOTES 3 -- 7 1 ! J SHEET I , •;JI -� �' ;/lc•,. TAPCO?I 3/16" ':APCON —•\ II INTERIOR , :.._.) ,'�_,,,,,,,,,,,,1„�1, \;!. �_- a Q3ft_r_Jl F [l' w.l l T 11 n -- _- _____ •' r i-'I_�1�1 _ IN,, —,:±__,52 � I it _JI LL --�If� 1vnr.L I �f , C 1�-� 1 ----_, 4 s Ij �, EDGE _ _ -__ , ini 0 a4 _ ' I aFdCE )_ r— I I � I \\ `\:i�� {. '°• — �_ EXTERIOR EXTERIOR INTERIOR �___.._._ I �.rER r-IJn SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION ti BACJ'ER ROD �� .!I---J _i /16” iAPL:IJP,, Ar PRO`✓ED �.. f`'° it If i../ SEALANT 'N Com'` /2 `)il• • S L:!11+iI.,, �b 1/4" MAC. NOTES: r;SEE NOTEL I'': BUCK — ‘111____---1 ----,-T.-.-_.2.1.---- �t� �I— —F1 j SHIM SPACE 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SEE 3 - 7 \' �J L� NOT SHOWN FOR CLARITY. SHEET i --Ia �L \ �,L------1-1= -1--_ 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE fI f DESIGNED IN ACCORDANCE WITH ASTM E2112 =.ONC'RETEii,4ASOHRY - _ ��' _=��•I{{II `= -- --Ct—'•1 „ EASTERN ARCHITECTURAL SYSTEMS �1111IM B'i OTHERS ��� ' • , 'l ' I i/:!" bold. �'�►.e Ea �e�� EASTERN l ET.SSMON MRLY \\\. R. tL ���/ o Eh?iEDi•AEI•T A::.'::w�.`.:.„,A „..H py. ',:....s.,.• \\ \ :/ 1000 BAVAS tOAO N. J 9 a , , , FORTNYERS,RORIOASl91] =�/.•�\,,wt.e .d1 SERIES 1 441 VINYL SINGLE HUNG •j//( I 54 X 72 — - _ 2 1/2" MIN. __. J INSTALLATION DETAILS STAT OF 'f�= EDGE DISTANCE VERTICAL CROSS SECTION DRAWN: V.A 110 REV SP '�C0R,., � \\ A.IYf os-oosss B �� Ss�ONAL EaG�\\ CONCRETE/MASONRY INSTALLATION /��IIII I 1111>>`\ SYALE NTSI'MEE,5 OF 5 CASTE 7/29/08 .'iun.ua LJuuu111E'j‘..vuti Vluul\. ••Y"-"�""""""""""a��a'r r rr r r — �. — .. �y�-.ic a� ",sy„v ez.��.��*--c:� r .vw- >�:..F�,}`a a.a�-_� �,��'a3 ,,.�+t,�'.c:. ',-,f.‘1,.:,-.. �PF- ' s .�� c �� �: -'f a 'S ��� 'Samar F "` ""� 3 yi.F . F' 1pF C6PAF £6T.7 DF . s.-'�i k ^S r ,s.h, ."F ...i" ; ))1y ➢. a .1Sus ness 8- ProfessionatirRegulati4n. i k�� t 4 -� .‘t..,;:,...., IP y 1 .,.2,,,,..;=-,--,yr �" -` A y' a .y"," 6C''"., 4.-..k..;_'y" �t.. + '7WKw3 ^.,. ^ n� S..r: _._ 5!'''"..-- ':. 4....s.,...: ,"S..a. _.• ,.....c,.._e% '^.3scc,.... '• ��i+ Els�r� Grams..�ae,G�r Rs `, nes o�( s3Grrs ro�;rA,�"5 i2 BCIS Home i Log In ; User Registration l Hot Topics i Submit Surcharge Ste s&Facts , Publications ; FBC Staff , BCIS Site Map ; Links I Search QRCt3 Product Approval , ,USER:Public User Product Approval Menu>Product or Aopfication Search>Application Ust>AppEr2tmn Data —...- *.V.S'i C ".:mss t,'C?3_,. r 9Fr=ici~°bW`:; ;, FL# FL14610-R4 rb chns=_Cser r, a.45 Application Type Revision n Code Version 2014 Application Status • Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 3.6341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext 4305 jflesher@easternmetal.com Authorized Signature James Flesher jflesher@easternmetal.com Technical Representative Timothy 3. Hoard Address/Phone/Email 10030 Bavaria Road Fort Myers, FL 33913 (800)432-2204 Ext 4314 thoard@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 AAMA/WDMA/CSA 101/I.S.2/A440 2013. ANSI/AAMA/NWWDA 101/I.S.2 1997 ASTM E1886 2005 ASTM E1996 2005 ASTM E1996 2009 TAS 201 1994 TAS 202 1994 TAS 202 1994 1 of 4 9/26/2017,7:39 r 1U11UC.ULL11UU1g,\.UUo LIIU LIc uu.pa.//11Vlllf(iVU11LL111b.Vibl tla/�!14YY"`�''�"Y"`1 rn ••`-"- V`1`C••La/.. Equivalence of Product Standards Certified By • Product Approval Method Method 1.Option A • Date Submitted 04/22/2016 Date Validated 01/30/2017 Date Pending FBC Approval Date Approved 02/02/2017 Summary of Products FL# Model,Number or Name Description 14610.1 143 Vinyl Impact HR(Horizontal 143 Vinyl Impact HR(Horizontal Sliding Window) Sliding Window) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14610 R4 C CAC NI013349.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2017 Design Pressure: +50.0/-50.0 Installation Instructions Other: Maximum Size Flange 74"x 63"Tip to Tip&Fin 73" FL14610 R4 II 08-02869.pdf x 62" Buck/Box.Approved as XO, OX. Frame material to be Verified By: Luis R. Lomas, P.E. 62514 rigid PVC from Deceuninck North America AAMA Certified Created by Independent Third Party: Yes (DEP-1) Evaluation Reports FL14610 R4 AE 513680.pdf Created by Independent Third Party: Yes 14610.2 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14610 R4 C CAC NI006178.02-R3.pdf Approved for use outside HVHZ:Yes FL14610 R4 C CAC NI006178.04-R2.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +45.0/-45.0 06/30/2020 Other: Maximum Size 53"x 51", OX or XO Installation Instructions FL14610 R4 II 08-02698A.p df Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party:Yes Evaluation Reports FL14610 R4 AE 513477A.pdf Created by Independent Third Party: Yes 14610.3 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14610 R4 C CAC NI009471.01-R2-signed.pdf Approved for use outside HVHZ:Yes FL14610 R4 C CAC NI009471.03-R1-signed.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +35/-35 04/30/2020 Other: Maximum Size 112"x 63",XOX Installation Instructions FL14610 R4 II 08-02692.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14610 R4 AE 513467 .pdf Created by Independent Third Party: Yes 14610.4 Series"1000"Aluminum Non- Series"1000"Aluminum Non-Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14610 R4 C CAC NI006178.01-R2-signed.pdf Approved for use outside HVHZ:Yes FL14610 R4 C CAC NI006178.03-R1-sicined.pdf of 4 9/26/2017,7:39 A iunuarstaming c,oae vnune nups:iinonaaouuamg.orgipripr app_au.aspx!param=wchvACZWIL., Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: N/A 06/30/2020 Other: Maximum Size 74"x 63", OX or XO Installation Instructions FL14610 R4 II 08-02693.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party:Yes Evaluation Reports FL14610 R4 AE 513468.pdf Created by Independent Third Party: Yes 14610.5 Series"FWI 1000"Aluminum Series"FWI 1000"Aluminum Impact Horizontal Sliding Impact Horizontal Sliding Window Window • Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14610 R4 C CAC NI010658.01-R1-signed.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/28/2020 Design Pressure: +100.0/-120.0 Installation Instructions Other: Maximum Size 74 1/8"x 63",OX or XO With High FL14610 R4 II 08-02679.pdf Rise Sill Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14610 R4 AE 513454.pdf FL14610 R4 AE NOA 14-0423.16.PDF Created by Independent Third Party:Yes 14610.6 Series"FWI 1000"Aluminum Series"FWI 1000"Aluminum Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14610 R4 C CAC NI010658-R1-signed.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 02/28/2020 Design Pressure: +100.0/-120.0 Installation Instructions Other: Maximum Size 120"x 63",XOX With High Rise Sill FL14610 R4 II 08-02680.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14610 R4 AE 513455.pdf FL14610 R4 AE NOA 14-0423.16.PDF Created by Independent Third Party:Yes 14610.7 Series"FWI 1000"Aluminum Series"FWI 1000"Aluminum Impact Horizontal Sliding Impact Horizontal Sliding Window Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14610 R4 C CAC NI006149.01-R1-sianed.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2019 Design Pressure: +80.0/-80.0 Installation Instructions Other: Maximum Size 72"x 60", OX or XO With Standard FL14610 R4 II 08-02678.pdf Sill Verified By: Luis R. Lomas, P.E.62514 Created by Independent Third Party:Yes Evaluation Reports FL14610 R4 AE 513453.pdf J FL14610 R4 AE NOA Saflex PVB 15-1201.11.pdf Created by Independent Third Party:Yes 14610.8 Series 3241 Vinyl Non-Impact Series 3241 Vinyl Non-Impact Horizontal Sliding Window Horizontal Sliding Window Limits of Use Certification Agency Certificate .% Approved for use in HVHZ: No FL14610 R4 C CAC NI010634.01-R2.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 03/31/2021 Design Pressure: +50/-50 Installation Instructions Other: Maximum Size 71 1/2"x 59 1/2", OX or XO. FRAME FL14610 R4 II 08-01214A.pdf MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH Verified By: Luis R. Lomas, P.E.62514 AMERICA AAMA CERTIFIED(DEP-1) Created by Independent Third Party:Yes • Evaluation Reports FL14610 R4 AE 511793A.pdf Created by Independent Third Party:Yes 14610.9 Series 4241 Vinyl Impact Horizontal Series 4241 Vinyl Impact Horizontal Sliding Window Sliding Window of 4 9/26/2017,7:39 A :,lona tsuilomg Uocte Online IITips://nonuaouilcoag.uigIp1Ips_app_uu.aspx:pawn=yv 1 v Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL14610 R4 C CAC NI010634.02-R4.pdf Approved for use outside HVHZ:Yes FL14610 R4 C CAC NI010634-R2.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +50/-50 03/31/2021 Other: Maximum Size 71 1/2"x 59 1/2",OX or XO.FRAME Installation Instructions MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH FL14610 R4 II 08-00937A .pdf AMERICA AAMA CERTIFIED(DEP-1) Verified By: Luis R. Lomas, P.E.62514 Created by Independent Third Party: Yes Evaluation Reports FL14610 R4 AE 511490A .pdf Created by Independent Third Party: Yes Back Nexti Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessbity Statement::Refund Statement Under Florida law,email addreee a are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by tradtional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wth an email address if they have one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approvalov� Accepts: 'ga l Credit Card Safe • c i-of 4 9/26/2017,7:39 p RECISIONS REV DESCRIPTION DATE APPROVED A REVISED PER NEW TESTING 02/23/I5 R.L. NOTES: 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH I. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE REQUIREMENTS OF THE FLORIDA BUILDING CODE. DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING INTO METAL STRUCTURE USE //'10 SMS OR SELF DRILLING SCREWS WITH TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WAIL. RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 17. ALL FASTENERS TO BE CORROSION RESISTANT. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUSE BE 15. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR ANCHORED THROUGH TETE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063-15 1/8" THICK MINIMUM MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 19. APPROVED CONFIGURATIONS: X0, OX. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED 20.UNITS MAY BE INSTALLED WITH OR WITHOUT FLANGE. COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 4 II. SI-1IM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABI.E • OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 1 I. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE (110 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:02/24/2015 •�"jjj EASIENNMO01EClURI1SY91E119 \11111I/// Easters 109!1EASIEPtiOOMADVISYEIVICC USIPPLY `\\� R, LO I�i ALL „w. .. o -, FORTMYERS.R]191] V� J ••GEN(�' 9ifi;. • TABLE OF CONTENTS ;SERIES 3241 HR PVC HORIZONTAL SLIDING WINDOW o.�261 • 71 1/2" x 59 1/2" .v AT i/,( c spa SHEET NO. DESCRIPTION NOTES OP 0'. A. 1 NOTES I DRAWN: DWG NO. REV .i�' S.LORM.G\ .' 2 ELEVATION Esc H DATE 08-01214A A ii/S�ONAit ��\\\ 3 — 5 INSTALLATION DETAILS NTS I 01/29/10 I 1 OF 5 Nir IREVISIONS 71 1/2" MAX. FRAME WIDTH REV DESCRIPTION DATE APPROVED i I A REVISED PER NEW TESTING 02/23/15 R.L. I 11 .5/4" MAX, 6" MAX. -----1— "� O.C. — 6" MAX. 1 1 ! l --) i 1 --__--1 3 — 6" MAX. \ —f i — I 15 1/2" MAX. O.C. 59 1/2" MAX.. FRAME A J �:� HEIGHT rt . 1 ` — NOTES: — _ 1. MAXIMUM SASH SIZE: 35" X 56" I ti' MAX. / — _ _ 2. MAXIMUM D.L.O.: 32 1/2" X 54 1/2" 1 1- —� { I i I I I 1 3. (8) 3/8" x 3/16" WEEP SLOT 3" FROM EACH CORNER AT BOTTOM RAIL AND GLAZING I I POCKET SERIES 3241 HORIZONTAL ROLLER PVC HORIZONTAL 4. (2) 1" X 3/16" WEEP SLOT AT EACH END OF SILL INTERMEDIATE LEC I 5. (2) 3/8" X 1/8" WEEP SLOT 3 1/2" FORM EACH CORNER OF EXTERIOR SILL TRACK SLIDING WINDOW 6. (4) 1" X 1/8" WEEP SLOT 3" FROM EACH CORNER OF EXTERIOR SILL TRACK EXTERIOR VIEW 7. (2) 1 1/4" X 1/4" WEEP SLOT W/FLAP 3" FROM EACH CORNER OF EXTERIOR SILL FACE. DESIGN PRESSURE RATING IMPACT RATING I. ±50.0PSF NONE I SIGNED:02/24/2015 R EASTERN ARDIMCRIRILRIRIENS 41:61/ R I r](5f!/ �„wt mi 10]It DONEADIAS,ON OF ERRNEI RIPPLY . N\C 1R.IL /I , ' HAR NVru'.+aaw E'.^•LE ~ �I' �ne s'o.pv1.: FORTNYER FLI191] \ _ V • /�q ' A (Z)��fAL�I NI�� III.rCI�ID u'�ILE 1 ,;',{i"' e,�.u]m. %,,..,V,•y�G�NSF•.•P `- (2) IAL[ f��ffiylD� f ill SERIES 3241 HR PVC HORIZONTAL SLIDING WINDOW :::*/,10,7:• �•*=.. C ALLMINUVI>11NF EIABJTI 96800084)fA1"1�®IIL�li!EllNdffi11E 71 1/2" x 59 1/2" �,orir' ELEVATION I r'0 STF :ty` D. ALUMINUMf'aNF> EIMENliENcr9.:r) fy+(11E��P�13JDMTICM(�LIL :i0'a E ALUMINLMf 11Nf EN1(�9 300t207)�®V1BEILE DRAWN: DWc NO. REV :3lS:tLOR10P� .. TJH !ME 08—O 214A A . //�',ONAj"111111'c.\\�` NTS 01/29/10 I 2 OF 5 i lir REVISIOIIS _ 1/2" MIN. _ —'r — EDGE DISTANCE REV UESCRIPIION DATE APPROVEDI I 1 WOOD FRAMING - ---'—'- _ ___ A REVISED PER NEW TESTING 02/23/15 R.L. OR 2X BUCK BY OTHERS 1 3/8" MIM. EMBEDMENT _• _ ^ __I_ � ------.- I 3/8" MIN. / "—�L� 1/4" MAX. _1 EMBEDMENT BACKER ROD -- _� s , SHIM SPACE 1/4.' MAX & APPROVED I Y SEALANT I w SHIM SPACE B ' Q1111 141 f/10 WOOD SCREW _ 1/2" MIN. INTERIOR I —II - EDGE DISTANCE I�= //10 WOOD SCREW ( J -----"--v---=---- INTERIOR . (ate WOOD FRAMING X10 EXTERIOR oR 2K BUCK EXTERIOR 6 BY OTIIERS BACKER ROD & APPROVED SEALANT I p ! JAMB INSTALLATION DETAIL /11 - nl, /110 WOOD WOOD FRAMING OR 2X BUCK INSTALLATION 1—��7 SCREW BACKER ROD _frI.•U 1/4" MAX. & APPROVED n ,l r SHIM SPACE SEALANT LI 1 —I • LT4 - WOOD FRAMING "T---1- OR 2X BUCK 1 3/8" MIN. BY OTHERS EMBEDMENT 1_1_ 1/2" MIN SIGNED:02/24/2015 EDGE DISTANCE VERTICAL CROSS SECTION �7 EA6IERNMGUIE1ALOF SI STOMA 11R.lliii,, "17' I Ea,},i.b�j/ EA41CA Mei SlPPIY �\G R. 1, ////// • WOOD FRAMING OR 2X BUCK INSTALLATION III IeEn wnresm evE ��O\•••.••tt � t I: M:. w ". e000iva n�vn `\,...\G"4• QIP wY j SERIES 3241 HR PVC HORIZONTAL SLIDING WINDOW _*: 0 8 * NOTES: II 71 1/2" x 59 1/2" w I.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, INSTALLATION DETAILS ; UZ r IW� NOT SHOWN FOR CLARITY 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE I DRAWN: OAR NO. REV 1..ce,A�ORM 0 \ �.� DESIGNED IN ACCORDANCE WITH ASTM E2112 ;T J H 08-01214A A ii�ss/0"k^E�G\ SCALE NTS DATE 01/29/10 SHEET3 OF 5 /�IIIIIIIII\'_ . s REVISIONS • _.--•-r 3/4" MIN REV DESCRIPTION DATE APPROVED EDGE DISTANCE02/23/1I A REVISED PER NEW TESTING 5 R.L. j 1/4" MAX. METAL J r I q SHIM SPACE • STRUCTURE •nncav�t� 3t��.�� �J BY OTHERS -- iyj�- a � ' APPROVED--� SEALANT 7.1- s_t_r _.j L._-"Tel __ _ 1/4'� MAX. I zi r B SHIM SPACE 0 LL I. + INTERIOR �. 11 li --"( -2j;//10 SMS OR ii ,0 SELF DRILLING EDGE DISTANCE SCREW 3/4" MIN ‘11"1!: 11111 . 1. L!•I 1110 SMS OR SELF DRILLING SCREW Si p 1DCJ EXTERIOR --•-- - INTERIOR METAL BACKER ROD EXTERIOR STRUCTURE & APPROVED e BY OTHERS SEALANT JAMB INSTALLATION DETAIL v METAL STRUCTURE INSTALLATION I SEL SMS ON . SELF DRILLING j'-' I(��� SCREW BACKER ROD ../..... & APPROVED O i' SEALANT I/4° MAX. SHIM SPACE METAL la's ----"-' STRUCTURE ��..fficc�ciac>nac�cltma° "�:1- BY BY OTHERS I' EDGE 4DISTANCE SIGNED:02/24/2015 VERTICAL CROSS SECTION - EMIERNAROOIECIUMGIVENS 1111I I III1b METAL STRUCTURE INSTALLATION {/'�4h, IESSt�>rir, EMrew u9i.IOF V ��\�� R• L •QLD//// { !I { MUDOMESIR AVE �J`� • �9��f F ALUMINUM w FORT WM9,R11912 'Z.v • \CjENs• •� w�,•V'^•'"' 62TN2-2]01 = e• r NOTES: SERIES 3241 HR PVC HORIZONTAL SLIDING WINDOW -1*.j. ••* 71 1/2' x 59 1/2" _o�QYY//`//''r�1,,E�rr tvi� 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, INSTALLATION DETAILS I��D, SjA1' OF NOT SHOWN FOR CLARITY .(�, • 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DRAWL DWT SO. REV . <0.,4.:��O R1.P G\�� 1 DESIGNED IN ACCORDANCE WITH ASTM E2112 TJH 08-01214A A I /ids/p�A:rt;'e��` SCALE NTS !WE 01/29/10 ISHEET 4 OF 5 1 ��//111111111' 2 1/z" MIDI. _ REDSIONSI EDGE DISTANCE REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY - . 1 " - A REVISED PER NEW TESTING 02/23/15 R.L. • BY OTHERS �I•' . e " ° 4 , 1 1/4" MIN. OPTIONAL 1X BUCK '' EMBEDMENT SEE NOTESSHEET 1— \- ' ° ° a CONCRETE/MASONRY— T� , BY OTHERS 0■ `" 1/4" MAX. BACKER ROD J v -_ 1/4" MAX. OPTIONAL 1X BUCK & APPROVED r" SHIM SPACE SEE NOTES 3 - 7 ' ,,' SHIM SPACE SEALANT SHEET 1 ° B i e V a '9 3/1s" TAPCON • ° INTERIOR 3/16" TAPCON 3/1 1 O ISI 4_ 7 atEl- C7 nt\1U�1111hu1�-� G EXTERIOR INTERIOR2 1/2" MIN. . [� EDGE DISTANCE a gii O L2 EXTERIOR + BACKER ROD & APPROVED 1 1/4" MIN. SEALANT EMBEDMENT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION BACKER ROD --- � � I 3/Ist2 " TAPCON & APPROVED SEALANT ,_!> Iz 1/4. Ell " MAX. NOTES: OPTIONAL 1 X BUCK O_______--,___-10 , r SI TIM SPACE I.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, 1 SEE NOTE 3 7 \ l� + NOT SHOWN FOR CLARITY j - SHEET 1 \\\ �'� _ 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 CONCRETE/MASONRY SIGNED:02/24/2015 BY OTHERS ° ., ° °r° a ° • 4 • I EMIEIMMCIOIECIUML616IEIA 111NIIIIJ I 1 1/4r' MIN. e��Iti , ', 'E'/i a;1.(...-- BCI 1634 OJT W SIPPEV `\\\\\� R•• d�/// 4 °. = EMBEDMENT° ,° '•,,,o':'woo.^ " '- E06 OEI15.IL AAT .\� • GENS•fid,--....; fes- L—� SERIES 3241 HR PVC HORIZONTAL SLIDING WINDOW ' h•/A o... �51I -I _ 2 1/2" MIN. I__ 71 1/2" x 59 1/2" i �aC(trr�( ,�lsto7 EDGE DISTANCE INSTALLATION DETAILS 1D• AT OF VERTICAL CROSS SECTION • R� , %^�.•• A. fa.G_'��� I CONCRETE/MASONRY1NSTALLATION DRAWN; OWN 110. I I ice/ss`•••, \ I TJH 08-01214A A /// CONAL��\\ I SCALE NTS IDATE 01/29/10 ISHEET 5 OF 5 1 11111111 i