Loading...
1912 CREEKSIDE CIR - ROOF 0!AN-144 r,) ss. CITY OF ATLANTIC BEACH ,? 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 40.i)s) INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF17-0038 Description: SHINGLE AND MODIFIED ROOFING Estimated Value: 9560 Issue Date: 12/4/2017 Expiration Date: 6/2/2018 PROPERTY ADDRESS: Address: 1912 CREEKSIDE CIR RE Number: 172020 1220 PROPERTY OWNER: Name: WEEDER ROGER L Address: 1912 CREEKSIDE CIR ATLANTIC BEACH, FL 32233-4505 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: TURNKEY CONSTRCUTION (ROOF) Address: 5991 Chester Avenue#105 QA RUBEN DIONISIO LAVARIAS JACKSONVILLE, FL 32217 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. • 4006)4 City of Atlantic Beach APPLICATION NUMBER illi .0� Building Department (To be assigned by the Building Department.) ;, ; „ s 800 Seminole Road Q '�'r Atlantic Beach, Florida 32233-5445 ` \�� 7--- U ''' Phone(904)247-5826 • Fax(904)247-5845 y ,..,10, E-mail: building-dept@coab.us Date routed: f 0/ 7 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 912_ C[z -K S (Oe. 01(2., _...D........._- • . + ent review required Yep No Applicant: \ i) RN KCL- e_o S'-- Planning &'Zoning Tree Administrator Project: Roo F(i,-)CN A,.©(�(i'-----( 1) Public Works Public Utilities A-10 D 64 c 0 G..L_ Public Safety Fire Services ;Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection _ Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers — ' .f)hc'l Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ['Not applicable (Circle one.) Comments: BULLRING PLANNING &ZONING Reviewed by: Date: `0— '/17 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 { Building Permit Application OFFICE COPY City of Atlantic Beach 800 Seminole Road,Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (904)247-5845 Job Address: 1912 CREEKSIDE CIR,ATLANTIC BEACH, FL 32233 Permit Number: ROGUE= 17— 003 Legal Description 36-63 09-2S-29E, SELVA MARINA UNIT 12, LOT 9 RE# 172020-1220 Valuation of Work(Replacement Cost)$9,560 Heated/Cooled SF 1894 Non-Heated/Cooled • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s) (Circle one): Commercial Residentia • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: RE-ROOF WITH OWENS CORNING ASPHALT SHINGLES. 27 Squares Pitch:6/12. 2 Sq.Modified Bitumen Florida Product Approval# L i!0''7 /t rZ 1—(--'2-5-3 3 — A-( S- for multiple products use product approval form Property Owner Information Name: ROGER L WEEDER Address: 1912 CREEKSIDE CIR City ATLANTIC BEACH State FL Zip 32233 Phone E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: TURNKEY CONSTRUCTION&MAINTENANCE,INC.Qualifying Agent: RUBEN LAVARIAS Address 5991 CHESTER AVE,STE 105 City JACKSONVILLE State FL Zip 32217 Office Phone 904 900 1069 Job Site/Contact Number 904 343 4985-JUAN TORRES State Certification/Registration# CCC 1329475 E-Mail JULIE@CHOOSETURNKEY.COM Architect Name&Phone# N/A Engineer's Name&Phone# N/A Workers Compensation American Interstate Insurance,AVWCFL2598332017,EXPIRATION 5/6/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECO' ! YOUR NOTICE OF COMMENCEMENT. • (Signat a of Owner or Agent including Contractor) (Signature of Contractor) Signed and sworn to(or affirmed)before me this a.2, day of Signed and sworn to(or affirmed)before me this day of , 2b(7 ,by 9-P--v Sep --errt_j-, i'7, by (H') b4A.. 4-4 AC 4 (Signature of Notary) (Signature of Notary) "it �c'JULIETT MANZANO '0 JULIETT MANZANO e MY COMMISSION N FF109596 MY COMMISSION N FF109596 [ ]Personally Known OR c`Pnos\ ` EXPIRES.April 03,2018 {�Personally Known OR oP EXPIRES:April 03,2018 Produced Identification [ ]Produced Identification Type of Identification: �Q4 Type of Identification: Doc # 2017221704, OR BK 18131 Page 2257, Number Pages: 1, Recorded 09/28/2017 at 09:37 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 OFFICE COPY Permit No.P90►�— `��OJ d Tax Folio.No.g L -2 D NOTICE OF COMMENCEMENT State of FLORIDA County of DUVAL The undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. 1.Description of property: (legal description of the property,and street address if available):_ 36-63 09-2S-29E, SELVA MARINA UNIT 12, LOT.9 1912 CREEKSIDE CIR Atlantic Beach FL 32233 2.General description of improvement: RE-ROOF 3.Owner(name and address): ROGER L WEEDER 1912 CREEKSIDE CIR Atlantic Beach FL 32233 a.Owner's Interest in property: FEE SIMPLE b. Name and address of fee simple titleholder(if other than Owner): 4.Contractor: (name and address): • TURNKEY CONSTRUCTION AND MAINTENANCE, INC. • 5991 CHESTER AVE,STE. 105,JACKSONVILLE, FL 32217 a.Contractor's phone number: (904)900-1069 5.Surety(name and address): N/A .a.Surety phone number: b.Amount of bond:$ 6.a.Lender: (name and address): N/A b.Lender's phone number: 7.a.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.1.3(1)(a)7.,Florida Statutes: (name and address) WA b. Phone numbers of designated persons: 8.a.In addition to himself or herself,Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. b. Phone number of person or entity designated by owner: 9_Expiration date of notice of commencement(the expiration date is 1 year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF • COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR. PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE 30B SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINAN w • . INSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF • ME CEMENT. / Owner's Signaturiei1 Print Name: 1).70' +�i2'SF Title/Office: The foregoing instrument was acknowledged before me this 2-2- day of S !re ,20 (7,by.Po&et as (type of authority,e.g.officer,trustee,attorney in fact) for(name of party on behalf of �2m Instrument was executed) who(check one)—is personally known to me or who produced l L+ as identification and who affirmed that all the above statements are true and correct. Sw+w Signature of Notary:':g•-•,(.11:61— JULEETT MANZANO. AW,MY COA1A715510V R FF109556 My Commission Expires: �?f,1 2 JJ �Q/g ",c•�noe'OExPiRcS:April 03,2018 ,r OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: w 6 £2 CT Permit # Roo F n-co 3? Project Address: 171 c Ci -e-/c 51 btR LA-r"" LTi 10-i\-1 C rt. 3 2-1- As 2As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A.EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional -4.Roll up 5.Automatic 6. Other B.WINDOWS 1. Single hung 2.Horizontal slider 3. Casement 4.Double hung 5.Fixed 6.Awning 7.Pass-through 8. Projected 9.Mullion 10.Wind breaker 11.Dual action 17. Other Category/Subcategory Manufacturer Product Description mutation of Use State# Local# E. SHUTTERS II 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5.Roll-up 6.Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates 3. Engineered lumber 4.Railing 5. Coolers-freezers 6. Concrete admixtures 7.Material 8.Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight • OFFICE COPY EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY ERD 353 Christian Street Oxford,CT 06478 (203)262-9245 EVALUATION REPORT CertainTeed Corporation Evaluation Report 3520,03.04-R19_, 20 Moores Road i FL2533-R18.�-' Malvern,PA 19355 Date of Issuance:09/19/2005 (610)651-5847 Revision 19:06/06/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Flintlastic®Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded by the words'Trinity I ERD Evaluated"may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6,plus a 57-page Appendix. Prepared by: ,,,,,,,,,,,�,, - ,�aQ-ep gate.,r. %.''` 5 -O';a�:. The Nairn&seat appearing was authorized by Robert Nlemmen, Robert J.M.Nieminen,P.E, s' . c P,E.onociaction.mndoes not serve asaneleamNe,nysigned Florida Registration No.59166,Florida DCA ANE19B3 :Fz)p ,S,',, document.honed,sealed ha,deopfn bare baee transmitted to he • Product Approval Administrator and to the named,JOot CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research &Design, LLC.d/b/a Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY-ERD Entity Examination Reference Date ERD(7576049) FM 4470/4474 CTR-SC9175.09.16-1 09/06/2016 ERD(1S76049) FM 4470/4474 CTR-SC11590.08.16-R1 09/06/2016 END(1516049) FM 4470/4474 CTR-5C12255.12.16 12/27/2016 FM Approvals(7511867) FM 4470 0E3A2.AM 03/30/1982 FM Approvals(7511867) FM 4470 3W0A4.AM 03/16/1993 FM Approvals(1511867) FM 4470 3W0A2.AM 03/17/1993 FM Approvals(5T1867) FM 4470 3W0A3.AM 03/17/1993 FM Approvals(T5T1867) FM 4470 124A6:AM .09/11/1996 FM Approvals(1511867) FM 4470 338A1-AM 09/30/1996 FM Approvals(1571867) FM 4470 2D5A9AM 06/22/1999 FMApprovals(7571867) FM 4470 3009502- 12/12/2000 FM Approvals(7ST1867)- FM 4470 3008869 03/19/2001 FM Approvals(1511867) FM 4470 3009610* 10/15/2001 FM Approvals(1111867) FM 4470 3006025 12/28/2001 FM Approvals(1511867)' FM 4470 3012321 .07/29/2002 FM Approvals(7571867) FM 4470 3009814 09/06/2002 FM Approvals(T571867). FM.4470 3014502 04/04/2003 FM Approvals(7571867). FM 4470 3015444 07/11/2003 FMApprovals(1511867) EM 4470 3014692 08/05/2003 FM Approvals(5T1867) FM 4470 3014751 08/27/2003 FM Approvals(5T1867) FM.4470 3018579 10/09/2003 FM Approvals(7571867) FM'4470/4474 3020703 07/30/2004 FMApprovals(1511867) FM 4470/4474 3021759 06/03/2005 FM Approvals(1571867) FM 4470/4474 3022038 04/05/2006 FM Approvals(7571867) FM 4470/4474 3023458 07/18/2006 FM Approvals(1511867) FM 4470/4474 3026128 08/04/2006 FM Approvals(15T1867( FM 4470/4474 3024311 11/01/2006 FM'Approvals(T5T1867( FM 4470/4474 3025766 11/13/2006 FM Approvals-(1511667) FM 4470/4474 3028410 02/19/2007 FM Approvals(1511867) FM 4470/4474 3026964 07/25/2007 FM Approvals(7511867)- FM 4470/4474 301262 11/30/2007 FM Approvals(7511867) FM 4470/4474 3031199 12/23/2008 FM Approvals(7571867) FM 4470/4474 3032172 06/12/2009 FMApprovals-(TST1E67) FM 4470/4474 3037127 01/11/2010 FM Approvals(7511867) FM 4470/4474 3039648 12/02/2011 FM Approvals(T571867) FM 4470/4474 3046104 08/13/2013 FM Approvals(7571867) FM 4470/4474 3048520 09/19/2013 M7I(1512508) Physical properties DXO8C4A 03/22/2004 MTI(1512508) Physical properties DX20E3A 03/22/2004 MTI(7512508) Physical properties 13X20E3A-001 01/04/2006 M71(1372508) Physical properties AX31G8A 08/21/2008 'MTI(1512508) Physical properties .AX31G8D. 09/05/2008 - MTI(TS1-2508) Physical properties AX31GBF 06/05/2009 MTI(7512508) Physical properties. AX21G8C 01/28/2011 PRI(7575878) Physical Properties CTC-032-02-01 01/16/2008 PRI(1575878) Physical Properties CTC-034-02-01 11/24/2008 PRI(7575878) Physical Properties CTC-066-02-01 08/08/2011 PRI(7575878) Physical Properties, CTC-067-02-01 08/08/2011 PRI(7575878) Physical Properties CTC-068-02-01 08/08/2011 PRI(1515878) Physical Properties CTC-070-02-01 08/08/2011 PRI(1575878) Physical Properties CTC-071-02-01 08/08/2011 PRI(1575878) Physical Properties CTC-093-02-01 08/08/2011 PRI(1515878) Physical Properties CIC-116-02-01 .04/03/2012 PRI(1575878) Physical Properties CTC-183-02-01 10/04/2013 PRI(7575878) Physical Properties CIC-259-02-01 12/11/2015 ULLLC.(QUA9625) Quality Assurance Service Confirmation,R11656 Exp:07/03/2017 Exterior Research and Design,LLC. Evaluation Report 3520.03.04-119 Certificate of Authorization#9503 F80 NON-HV12-EVAWATION FL2533-918 CertalnTeed Corporation Revision 19:06/06/2017 Page 3 of 6 • TRINITY ERD • 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless.retained specifically for that purpose. 5.2 This Evaluation Report isnot for use in HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4-unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction; Load resistance of the roof deck shall bedocumented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1510. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX- 1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existingroof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data.Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 Forbonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing In accordance with ASTM E907; FM Loss, Prevention Data Sheet 1-52 or Testing.Application Standard TAS 124. 5:12 Metal edge attachment(except gutters),shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance inaccordance with ANSI/SPRI ES-1 or RAS 111;except the basic wind speed shall be determined from FBC Figure 1609. 5.13 All products in the roof assembly shall have quality" assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3. Exterior Research and Design,LLC. Evaluation Report 3520.03.04-R19 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION -FL2533-R1S CertalnTeed Corporation Revision 19:06/06/2017 Page 5 of 6 -I TRINITY ERD • CERraNT®FLINMAsnc®MmReoBa nedQ*p axTs&AFFucAliaiMmms(oarrupeo) Reference layer Material Application Base RintlasticLitre R9ySu1SBase;RintlasticBass 20T 93STA • Ry One or more FlintladicUtra Fbly SMSBasa RintlasticB3se20T Torch-Applied teasramArpdeal Cbp RintlasiicR2Qp30T;RintlasticFRUp30TCDolaar,RintlasticG S FlintlasticGISQlol9ar,RintlasticG1SFR RintlasticGfSRRmol9ar,RintOad AFP TA Bye Ole or more Rintlast icAFP Base T;RintlasticSTA;RintlasticSTA Rus (Atvram-Avpuea) cap RintlasticSTA:RintlasticSrARim RintlasticGrA;RintlasticGTA CbW9ar;RintlasticGTA-FR RintlasticGrA-FR Torch-Applied O.ml9a 936.6411 BaseIRy Back Demand BE193Sleet;Rintlasticlitre Gas S. 94f-Adhering (93$s41-Achning H,trid%9imW Base':Rirtlastic SA RyBas c:Rintlestic SA Mid Ry SEES4 Ry Rintlastic SA RyBase;Rint lastic SA Mid Ry Off-Adhering (SA 8iFAOienng) UP'.RintIasticSACap;RinttasticSACap md9ar RintlasticSACep FR'RintlastiCSA-03 FRODol9a 15. Mc Mamtni r ,R eiciheresiit of teing(or wind lo reai bad ewind loads Refer toFBC1609for determir ion ofdesign wind loads Exterior tewarch and Ceagi,LLL Nb/a Trinity)0,47) Evaluation%port 3520.03.04-R19 for 82533-R18 Certificate of Authorization#9503 • RaCtJON-t-NHZEVALt1AT1ON F2vidon 19:06/0612017 F epaed by.Fbbert I feminen,FE59166 ( rtainTeed Corporation;(610)651-5847 Appendix 1.Page of 57 it '- t} . ej +4 • • :,:t..-4.0.0M50-'•,'"-."..fi,'''' '' ''' zig c- 1Y" f, Erts'' Sfiey ,s w � � A�s} 9 c; tC L} t O .© .1 '7?-! G 3 7 J � c' ' "s- � v k,r r., ;/ s . lgI � �.7r771, 1. 74'...': t, - ' Pf ' 3. ,be �� ,' C 0 "t Z �' h • Jri, - - ' {L,-;-..,,,,,i0„. ; t � _4 r yt y .r' 'F, "[ _g ; j ;.+.:**.. i ' ] 4+a . '41t6. .,..',4 ,' " '''':.5:11,4,!.'.4.,(''.14.4,-.'.,,..-11cii","41' -..r .',.-1.r:.-;% ;,,,z4,1471,4,: '34 Tif0-444:,,,..,.. .:,':.'',:.,.,'. ;....,' ' ,.-.,..::w'..,.,'A.., P4145,. , ,, ,. . • ,:: - , --.,,,, --„,„, - - �'3 7 'Se' :"�, 1` 5,%,X*,,,", t s v - . ,ie; ;xEy. „,,,J.„0„,..,,,•. ,, ': ' '''''' '1'4=1-,-- M.1:0-.4'V- �k'Y s eM t }ty c L . x.. p. 2 + :r ,” q i ' 'tel -'- '':i4d( a-""d .'711 :40, `4. a ., C.. ie( 41041 ,.,,,...„,-„,„,-.„,„,,,.4„,,,„,„,,,,,„:„.„,,•:.,,,,,,,,,:„.„,,,,,,„,::,.,,.„.,„,._.„,„„:„...„:„,,,,,,„,„.„,,,,,,,,,„„:„.„-,;-„,„,„,„„.„,,,,-,,,,-,,,,:;,,,,.,„.„,,,,,,,,..,,,,,,:,„•,,,-,,,,, ..-„,,,,,,,,,,-;,.,,, s 14 ,,, .,,,,,,44,,m4,,,;,,k-..,w,r...isig..).-„,4„,,,,,.,..':: :;tkOttefAV?,..} ':,74i z -g ' „,,,,,,,, ,,,,-,P*---,,,---- ra � �#r ° xi ��F.. h3c+3 J. 4 F et ¢ — - '„ [d gay 3y' r ---!I''..:"":---.,7-.:1- :::-'4 3 u 4qa 1 f jtillVy� "=skww;44s+:._pYij'i ” ��w:r�.'. _ . • .-- �� `° --'• •i. _._..:� 4. .4e„,.1._ri,t,_,..$7`..v.,1,,,, I NI; ), SAINT GOBAIN Goes down fast. Stays on strong.- Energy Savings Flintlastic SA performs in all the right ways. Flintlastic SA Cap and SA Cap FR are available with What's more important to you?Speed of installation, highly reflective granules, meeting ENERGY STAR' durability or appearance?The Flintlastic SA requirements for cool roofs. Specific product details can (self-adhering)SBS modified bitumen low slope roofing be found on producttechnical data sheets or by viewing system is a premium performer in all these areas. www.energystar.gov. What is the SA system? The Flintlastic SA Family of Products With high quality materials bottom to top,components CertainTeed offers two types of primers for use with of the Flintlastic SA system include: Flintlastic SA systems.FlintPrime'asphalt primer and Flintlastic'SA NailBase(mechanically attached) FlintPrime'SA quick-dry primer are designed to enhance Flintlastic'SA PlyBase(self-adhering) the adhesion of self-adhesive roofing membranes. Flintlastic"'SA MidPly(self-adhering) Available In 14 oz spray cans, 1-gallon cans, 3.5-gallon Flintlastic',SA Cap(self-adhering) buckets,and 5-gallon pails. Flintlastic"SA Cap FR(fire-rated, self-adhering) FlintBond'SBS Modified Bitumen Adhesive is.a premium Flintlastic'SA Cap CoolStar(self-adhering) grade adhesive.With Flintlastic SA membranes,the Flintlastic'SA Cap FR CoolStar(fire-rated,self-adhering) FlintPrime SAtrowel and caulk grade are used for endlap,sidelap bead {quick-dry primer), and vertical flashing details.Available in caulk, 3 gallon, Please see page 12 for product detalis. 5.gallon and 55 gallon drums. What are the advantages? - No torches, no hot asphalt,no fumes and no mess— all of which means:application is much cleaner and h l faster.Plus,equipment needs are minimal.These T cgA?aks w®a,. ,�n advantages are even more_ amazing considering the t:fi , kK' :l long system life you can expect. } sn ' t '1j Where can I use it? Witinar The value associated with labor savings and safety.can y4 4 rhea be applied to any roof project. In addition, Flintlastic SA 2 roof systems are ideal when access to the roof is limited, ; ' - such as high-rise buildings.And no asphalt kettle means no odor,which makes SA systems an ideal solution on healthcare, education, hospitality and residences/condos where occupant comfort is tremendously desirable. Considerations for Intended.Use If multiple SA products are listed, products are.listedin order of warranty duration from shortest to longest,with the exception of SA Cap and SA Cap-FR;SA Cap FR is intended for use where Class A fire•rating is required(see UL Directory for Class A system specification). NOTE:Removal of theroof system(at end of life)may be difficult when adhering PlyBase orMidPly direct to a roof deck (i.e.wood,concrete). Deck Insulation/Coverboard* SA Anchor/Base SA Interply SA Cap Steel Required NailBase(MF) Optional SA Cap PlyBase(SA) - PlyBase (SA) MidPly(SA) (SA) SA Cap FR MidPly(SA) (SA) Wood%L\NIC/Other,i.e. Optional Yes PlyBase, MidPly Gypsum, Cementitious No NailBase(MF) Wood Fiber,Wood Planks Structural Wood Fiber,etc Concrete Optional Yes _ PlyBase, MidPiy No-Requires FlintPrime SA 'FlintPrime or FlintPrime SA may be recommended,contact CertainTeed Technical Services for more information. 1 • •Do not mix Flintlastic"SA membranes with other types of roof membranes. Flintlastic SA membranes Standard (Round Head) Roofing Nails and Cap are specificallydesigned to be applied together The (Note:CertainTeed does not permit the.use permanent top film of the MidPly, PlyBase and NailBase of plastic caps)For use with Base Sheet, Flash/ cannot receive torching, hot asphalt or othernon Termination Bar on Plywood Decks, Non Veneer self-adhering application methods.The Flintlastic SA Decks,Wood Plank Decks Cap(or SA Cap FR), PlyBase and-MidPly cannot be , applied to any surfaces other than as described herein. • Do not use cold adhesives with Flintlastic'SA Large Head Roofing Nails For use with Base membranes other than for flashing details and cap Sheet, Flash/Termination Bar on.Plywood Decks, sheet overlaps as described.herein. Non Veneer Decks,Wood Plank Decks • Refer to the.CertainTeed Commercial Roof Systems Manual for complete requirements. `' 1, 0, •When applying Flintlastic SA on slopes exceeding 1" - in 12",membranes shall be back nailed.When applied Base Sheet Fasteners for some Cementitious parallel to the slope, Flintlastic SA shall be blind-nailed Roof Decks For use with Base Sheet on Light at end laps 2"in from top edge, 6"o.c.through tin Weight Insulation Concrete, Poured Gypsum discs and to wood nailers. See General Requirements Section of the CertainTeed Commercial Roof Systems Specifications for details.. Application of Base Sheet Self-Locking Fasteners For use with Base Sheet Flintlastic SA NailBase May be used as an anchor sheet on Cernent/1Nood Fiber (mechanically fastened);.PlyBase or MidPly may be used as a base ply(fullyadhered),Beginning'at the ` }:i I' ) . _ low point.of the roof, mechanically fasten Flintlastic SA NailBase to nailable deck using appropriate fasteners Insulation Fasteners (see fasteners chart)..Start with:an appropriate roll width(1/3 or 1/2 roll)to accommodate offsetting ofWag sidelaps of subsequent layers of MidPly and/or Cap. tr,,,,.1 ` a sheet: Install so that no_sidelaps are against the flow of water.A minimum fastening pattern is every 9"on center on sidelaps and every 18"on center in two When using FlintPrime'SA, allow to dry thoroughly,but-no. staggered rows in the field of the sheet. more than four hours to retain tack-enhancing properties. Itis recommended to prime fasteners with FIIntPrime ram Z tg V¢ •I Aerosol before installing the base ply Before adhering a base ply,sweep the surface of the deck or insulation WkliWIZAWAt'4544*OgOaKWAWAW.V&WAN to remove'any debris that could interfere with adhesion.. x Start application.at the low point of the roof. Install flush ", - y to roof edge. Design layout so that no sidelaps are z *;,� against-the flow of water. Cut rolls Into manageable lengths.Fold the membrane back halfway lengthwise to remove the split release film. Overlap basesheetsidelaps 2"and endlaps.4". tilwArresf` Offset endlaps a minimum of 3'.Turn base sheet over -, -- ,t M i - - e ,- gqgarr facia by 2"and fasten. Do Not h ' r _ � x 5, Leave Base Sheet Exposed To r , The Weather.Cover in the same day:with optional SA interply and SA e" + a Cap/SA Cap FR. w kS 8A PlyBase/MidPly may be adhered ,F � ,v to mechanically fastened or adhered F - ri " � �� A c FlintBoard'ISO/FlintBoard ISO Cold,or direct to primed substrates ,,. (i.e..concreteroof decks,gypsum coverboards; etc). 3 '"- Follow the same layout and split release film procedures xry as for MidPly(or PlyBase),,but overlap sidelaps 3°and w `" endlaps 6 Use a weighted roller over the entire surface of Flintlastic SA Cap(or SA Cap FR)to secure it in place and prevent voids,working outward from the center of the sheet. As subsequent membrane lengths are installed, remove the selvage edge release strip just prior tooverlapping to keep the adhesive area protected and clean. specified,complete sheet metal flashing installation z . ▪ t y '1024,..17--41.-` � N r e 4,.r ; 3�i, ''''' 7" , 4` a using cut PlyBase or MldPly flashing collars at all flashing - l' } details.All cap sheet flashings installed to transitions that t t4 ritYnat 3' lIf overlap onto mineral surface must be set in a uniform ri ' . ° troweling of FlintBondr trowel grade adhesive: m „,'' . 4�F 'E▪ ' 4 4', Application of Flintlastic SA Cap r x =; i (or SA Cap FR) Before installing Fiintlastice SA Cap or SA Cap FR, sweep the underlying anchorsheet or base ply to remove any debris that could interfere with adhesion.To install Cut endlaps at opposing diagonal corners at an angle Flintlastic SA Cap(or SA Cap FR),start at the low point of approx.3"by 5-1/2"from the corners to minimize the roof with an appropriate roll width to offset sidelaps T-seams. from the underlying membrane a minimum of 18". FlintBond trowel grade is required on the entire Work withmanageable lengths for proper handling. 6"width of each endlap prior to overlapping. 4 c� a - Apply a uniform 1/8"-174"troweling of the F.IIntBond on the l 4 T t 4, entire width of the endlaps to the underlying membrane. 4x i Install the overlapping sheet.Always apply FlintBond L 4 T ms's Fr ,.'` r Z (extend beyond underlying lap minimum 1/4")on the :•_: �- .. ' .' 't 9 4 � entire width of any overlap when applying SA Cap `' - .iw: '° = a-,e (or SA Cap FR)over another mineral surface such as . .4i t#''443-4'1'; -'N„ 4 sm h R - I �f the SA Cap(or SA Cap FR)endlap. a -_ At all vertical and other flashing points,apply FlintBond P' trowel grade wherever there is an overlap onto mineral Z surfacing. Position SA Cap(or SA Cap FR)with selvage edge , $ . -{ -� release strip at high side of roof. Install in weather-lapped fashion,with no laps against the flowof water. Once positioned, lift and fold back(lengthwise)the lower �. 'A ;� ' half of the membrane. Remove the split release film 4 ' 0:`' '; and press firmly into place.Then repeat with the other s (high side of the roof)half of the membrane yam" ,,,,.04 lirt-IPS,a1, el ii 1 fl4P74 y; sty f. 1i7 .. life•' A„ -f _ ' - ?• Once the Membrane has had a chance to bond, check l `� ' a� y all laps and Joints for full adhesion. If the membrane 4 � "� a "' " can be lifted at any area it is not properly adhered. Nrv: ... w A seam probing tool can be helpful to check for small -�sjx �-- °L voids at laps: If necessary; use appropriate hand-held hot air welding tool and seam roller or an application of FlintBond to seal small unbonded areas if they exist. 5 .. . • Typical• Construction. ' Details - Flintias. " tie SA 2-Ply System Vera Pipe Collar Detail Drain Detail - ::,- ::. ...'',•-• ,iW:rslii-..:,.:-..1.',.:%'-...-.::.- ,'.4.:::: ;,..:):;f..:i• •....:,,....,-.s ,:?.--,.,,: tq..., V.giV.:Mi.----(5.XiMRiaq - •:•-. - • •?'.- -',..-:'.-iZ'r:'''..--';7: -.:-.: i,,,:i1:•0-.:*::::,, ,q,;e,F;;'''ig, ,.-,,,,,v.::vtil;-.•,$,7s. .,....,„:,y,..m,,4:-t, ,.v.pAi:.:.mm , . • ..i,,,.:c. r.,:ik, ,,',.4.,-,2..,,,,,,..4,..,,,,,,,43-4,,,,,,,,t.-,*,-,,,-,...,,,.'42,,,,,, Ank4felist- - •"T::4:*.Z%'.7..:P*0.-IM-AM-SIgikTfa4 . --' --'4.:e41'.;...0414:14....:3';'N'.:,`2.--Yt;W:•'&"0.:4gRMP;;'.• ..,-.-,-,?,----qkj gm • • ;421,',VA451MAASTRazNaggi4N • ' - . •-•.:i'' ,-.::,?,:--:-1,'' , .,_. - rOiiiii *V" •itir'. ',e41;f6-0.00"#10-4,1,L.414,4 : . .. -. -.....r.:...::-.:',, ..i:4:•.::,,t;;,..4.- iatl,,!•:-.**,,o*,,,.;:,....!,4'..1 ... , . „,.-f-04401-fR-Kitt . .-q.--1 - - ---•1...,..':sr0.1&''-;';'":- ..1.-.. ...,-,..,,'., „.%-,',.... .11g,..' 4k.---Its8taftre4 :',Vi: t:;'4,i%'Aikata±40-0-011V -tE4-S, • . --;;;- ''ii: :-Al4iliPjt.,'-:''',,'15•'-gisri4r,.. -,-ik. •V• 1Mili-ltWeat ___„_,--..A,3,,01,....-44,?„.: „ .:'„AViKk.k.,,k rig,,--.Wil - " -1.0.1$4'.='?a-,i, s,--„;-.„?.e', -,-,•,„. it-i- • • iz, w.--,:l.,-.::-1,-..,:,,,,,_.!,:z ,44,i,.., . , ,,,,/ pilig.=,.(1 .1,3 ,,,;,,,.•-.:,',...-4..A" -3-1',4:2-77,7.3:S*V.f3,3 ,-*-1 tOgGiiiO3iit'i?W.;,:.7:4 - ., s.to !i'4,7?.- .i.-;-1-,,V,:i.:,•;',ig=rlikgf,41.-"11:Pkiitg,g-t-Og'R•0 ,„.,..gm.zi..s.i.,,,,,,,,v; :••:•,..-.:- ,..:o.,A:- 4.",'.'t.:-...-',"•=, '41 Ti, .Y`o-,' 0'''''S'f-P4-tZania'N't*,41A,V ,-,,,]j'OAV-;_'..-i:3'.. .P:-.T.--.,,'.'r' -Ci ':•9', .':',30-''''. 24.7';',:,''''•, -, '-.--.3', '.......,.;!k ., • •,;,;, - ' .. vi,:!---;.4645:tiv,4 -, 1,--iM •-4,atig03',',:!:•-,.?;,.•.,,,,..7-•,,°4-•-•_.;:•?,•vz..i;se,e.„ ';',...--•,..: ,,''•••.7ft-4-',,,:p-,. . • 4„ ,...• - -,,k-, • '., ':":Y'r!-,--:. .',"•t7• .-':.: :'. 4 . ;k:TO, ;;-,., ,. .*,-,,, We'l,:.,- ' ''.•'-",14',..:..'"-.--'' - . -:.•.,•::- ,,, ,,A.v.2.-m-t e:',, ''' -.:.gtl '' la. '41."•''''.".''''' '',3a^::,,L.: :,,'I•."-t... . ,, -.49,.. ..;..'.':, '.' - . ..31...L,;•S‘,.'' YE• :cg-r0041 ge-- ,2,13,,.3,,.,.*46 3,3";;,,,Z,!rt4 ,1 .-4:34L-.,.,,,,k`''''': '... ...'. :-.•;r`Z:A..'',e,''\,..::..,.,, *•''. .,.-.44.1tk''' ..., ./ ,a,a:tunetigawiesieSaafiikijiNkt,-;::,::.•----. .. r . '''':';$IA-- '•:..; --'--:..°*,;:',:', :'.. -;.‘.4,';•' ; . , ' $--..'.•$-M-.14--4:;:f,:;;Vs';';;A:f .,::,,'.ftl." --,-;i:1,1 .'•:,, ..;.- . ,..lf,,,,:vIeloTtegit-4, , '-., '''''%4....- - .. .:-:---,:.•;. ..'.. -,044''''`e . ,,,,i,,,,?:;-4-w.:g04*,7,:co.:Wv*,WiTAPiiii,_itiP,.z;' ,.n.iitii.A,,,i,,,=•';.,-,- . ii...,,3 1:44fifsi. -1.4WizeWe - ::,f41;&'- r-,-,..,:•,",,v,r;,-;:•.,,,,,kr•N.,-,-At,-•;,-,--1:,•-•-,,"-,W ,1"•"•-i,',.".klygfigifiii---,;:,;-,,'",:,•-,-,--,--,-.1-•,4,>' .--,---.,"'•.. , -- .•., • : .:....47ax il-,g014;;4 -'=,r-tril -•4'$' :: -. .. ;'6;fr'; •,,,,.p?.r.,:.;?,17-- .11 ,.,..,t,„,,i,..., i1-1,g4.,..-..!.:W-Tare2-.V.AZ4-.--"L--4g",,i A-14;.-, 1.- ..,-;;,;4.0-- Natifailga-IsW;i5,-IgtOROinfet.Kft-A;.344g;,,`,44,7:A., i-.:.-,:;. ;'. :7.....k.'3,0,4'.4..-14.Wt-m,... -itr.s.rfr,--,,%•-;Visr,,tNn7,,?-gATC;;T3.170,.,ft.,; -.',!•rt-ZW*1,5.,:"A',4"0 ;',"V"''"Vi;M;04.'?",4-zi.f.:;:`,p;• . .54•.;;;:;A:V,;N;',,WfA:i:Fk0;P:Afk40Fimr*-aak.,,-4.,.,,,11 Inside Corner Outside Corner • ---..... . •"'. 'Z''.',1f,:10.N. ,--IL PAW Ctistil :..,-..▪!-4.:*,•,.,:cy,...„:„._-,,,,, 3i:;lii.,NaiV...;:-...t;,..,..CL-tx,-414:!it;:ittp1,0 1 _ II tiloti CAJPri3,r.F,,,..,„ ,4-'''" '-'•:::',. . -----.._ .:''.5.▪ 1tiP,74Fit .:-.:'''t? ', i ' '''.. I,.. .-'' 'i:..;.;-•••_,-V - - ''''''. ri..-.-,-,. ''''‘:;:i ..L;,.1.:V-,''''''';'----'---'; ;',., . .-),••,,- . - '';'..- ;•l''''j-';-• ,,,e;"?-`-; 4.Thil'itik EA:tip.Comada WI r u '---,-•''. '' gt;rcif.‘4,:-,-,1:::'" „ ' . • • , ,. . . 3_•;:afdlittofiltzt ;lie':'!.- --- '''--.1-`1, , ,..a.:!'..,., < ,,--•"! -..• , cr sortiwitit2 - -,,,,i •"•--..„ ----„, ,,..,..04,. ,.. -.- ....i, - ,t.. 31 . ,.... i ....,, . ' *. '-'• ,,.1,4:3-,.:A.. ,,,,,7_,,,. iqf IH . ,. ...,,,,,,„•,,•.- Ct., v 4'' '''' •-•,...., .. -,,, .. s'--•-. V#7• :,: 47..i:#"• :e. co,- . ' .. . ,•-/. ' . -i . r„...-• --,....„.„, • .. .,:....„j .,.- ..•-• _,-1 • ."- • ---h.„,,... • '•-.... ..-N4zr .,z... 7::-,,.: ,;"•••••A.;i ----- ,..-..- 4,F1005.401 FA tiikV - .- ---...., 'W.','1&-.,21-4:-. .'.*-: ''%- .‹.. ' .. ......-f'..i..' *?‘.,,:f. - ..:,,f >"::. . 641 in Fit*ila''''. 11...,, • -''', Off-V55Ct‹-:-'-'-; ;.-:'-:::-...-•*-t• _ -' r - _ • .X-7, iCIT--1',.- -.-.:- ;:.1.: .• : ---, --- t,;':i4-tegf . .' - Ef.,c.it3.1itutic StIlEaVffi :-.- :..tLrilar,:..0 - .„•,- ,,c,:11:;:p7.-, -#:045:40 nrt:i..:;;-.:-',.i: ' — C...kilin,Ftp-zeviii,,,- • " litatill.t.,V.P.T.,47,f;.3),44-44 !?•;::.;':-,.:.,' cn Pralllard .-• '...e'--:-.k.•lirs-:•!:,•;.-::..-.----•• 7,'..„. • . . • . . • 7 2-Ply System Specifications SPECIFICATION: SA-N-2-S SPECIFICATION: SA-C-2-S Flintiastic"SA NallBase,.nailed: Flintiastic SA NailBaso,applied using:hot asphalt,or Flintiastic SA Cap(FR),self-adhered. Flintlastic SA PlyBase or MidPly,self-adhered as base ply. For use over nailable decks Flintlastic SA Cap(FR),self-adhered. For use over non-nallable decks or . .•.; ti . ' approved insulation (Flintiastic SABase required over insulation) 1 4 End Lap • A. En•d Laps ' _, o"End Lap IFDSICrI it';p!'t S1ar erRd 11 e ' . Course 2l. 3'Apart imini 7 End.Lnp 13' Nails ,- .11 • I. ; ' Slagocrcd .f _.}.�.._........ i — ............. G#i a'Apar'RIO) II iiik 1. 3'I.ap ! '.}� • -'..5 .. 39' l' . - 1 • t,. t s' Erd 1 i 15'Y:. p . 3'Lap; La 't � p G. i . : '• • r. 9z� • r` 11,1.1 ,t SA 7N-2 s =:..: . L t Note:Fiintlastic SA MidPiy,FlintBond Trowel Grade andS::1:.'.'• '44..04:.0r FlintBond Caulk.Grade are needed for flashing details. ;and mineral surface membrane overlaps..FlintPrime:(SA) is needed for surfaces that require priming. Note:Fiintlastic SA.MidPly,Flinteond Trowel Grade and Cants FlintBond Caulk Grade are needed for flashing details In angles of roof deck and vertical surfaces;the and mineral'surface membrane overlaps. FlintPrime(SA) roofing contractor shall furnish:and Install an approved is needed for surfaces that require priming. cant strip with a minimum 3"face. Cants In,angles of roof deck and vertical surfaces,the roofing contractor shall furnish and install_an approved cant strip with a minimum.3'face. Roof System Ventilation Roof system as shown requires ventilation as per NRCA - recommendations. • 9 3-Ply System Specifications SPECIFICATION: SA-N-3-S SPECIFICATION: SA-C-3-S Flintlastic'SA NailBase, nailed. Flintlastic SA NailBase,.applied using hot asphalt,or Flintlastic SA PlyBase or MidPly,self-adhered. Flintlastic SA PlyBase or MidPly, self-adhered as base ply. Flintlastic SA Cap(FR),self-adhered. Flintlastic SA PlyBase or MidPly,.self-adhered, •For use over naifable decks Flintlastic SA Cap(FR), self-adhered. For use-over non-nailable decks or approved insulation a"End Lap--i I ' _..� .i. _ � _I. (Fa,?•,1,l%U' +gypnd .: E it - j a Er-1 L. 2 Lap Era LSps til Slav ereC . 13 ._._..1.... +`pa9(aril C..0 Laps + E,nggnu,:. } rJaifS^ { • Lap ,, T 3'Aral nr r,, t• -16.--- II� t _ 2 Lar. r { 398r' 3lw i ... la-1 y9 2'Lap , ' � i - .. , ...... Lir ?ti':,' End- { \ i'6,,,,.. , LA p � 26: . j, ...g-_ , +' ?, ;.� , : -lap >pF.. 0, 1 'Now Flintlastic SA MidPly,FlintBond Trowel Grade and FliniBond Caulk Grade are needed.for flashing details and mineral surface membrane overlaps.FlintPrirne(SA) is needed for surfaces that require priming. Note:Flintlastic SA MidPly, FlintBond Trowel Grade and Cants FliritBond Caulk Grade are needed for flashing details In angles of roof deck and vertical surfaces,the roofing and mineral surface membrane overlaps. FllntPrime(SA) contractor shall funiish and install an ais needed for surfaces that require priming. pproved cant. strip with a minimum 3"face. Cants In anglos of roof deck and vertical surfaces,the roofing contractor shall furnish and install an approved-cant strip with a minimum 3"face. 11 • CertainTe.ed Full Systems 'r-- ' r .„ .- : . . ,-„,,,,„,_:„ . ,._. ;'.(P.1,-, p'-AI r,.,,,:: . IVIZOW .• ,,,f x .,. , ,,, „, .y i K 1 "4-f..: '4 ,,,,,rfa-,. I...',-Y,.4,-,:-:-t...1.- :,;',.;.,1;-:--Ti ;:Z.,-.F,..,' - '— - •-. , -, ;,.. 're,..Lf '.'.:•'-''''',t '''--'76 :,'. •kir-,t'''T; -4'?,..,44 ,. - — • . '.. ,1 z,:;:; • _ .::.4-1- a � � '.g 7 Iom ) et . �. r i a-- •t Tr,';:. ',N:S'n .'asss 7ra>, . isa _,,,,, , ,,_,.,_ ., . „,,,,,., -„,:-, .4%*,,:'-.,1?-,,,'..-”.I',.,,-,q''.."."Viy.' "--,-,7,.: 3 t " i . ', , - ,-,'; 1--.1"' :gi. a t--f..4.::,.:-,:o. [ , 3+ .,e� },• 1,' rpt �5� d t Y^ 1-- -' 4..,,•1•-.,,,,,,-,:,,,,,,..0:: k.. r. If 11 • �.; -_. • Aft •rl t . t P 1 ` r y.a r+ 1 �s'�t a I., i(w l) jam . 0n.�Yl 7- :_ wf 1FI ; a, a e4r' a'- d9, x i ?, +r ,:f, - ,. C,, 'ill. �r'i",-;,144.. 6. ,,:a...." ° }.- p _w'...R, ..,,,,,,,,,,,,,,..--.4:,,, 6,4 b{ i tea'=F Y,ya_.t n,>.1 r'�MY.�`N y A,. +� + _ .a., x. ttt ' =S1 jve .a 1 4 f-.><;$- -.F3,#, g4 `{' '-' ` ' `. ts�` ' r �v, �.: i . .ii; c 'l<„ip} '''•-• 4` -' M'1�-I ',•-; ,:? :4:. -''':Af-1- 1-7.- ±:::::triej-t 7..''''`'.*:..'r: -'4 '!•:... "' :':1,1.''';.:e '',1 '4,:-' il:ai-IC,--•-•'::.:al:.*‘7.,..'4-ZZ-.5iikt.f.:VY45. , 1 ,:,.,.,;,,,_i.:1,%''''.4'''' 'k 9 'e=�3n E'.'�' d S''Sy 4 �"k : W. '",,,71-'1)47 — "i`' Ao e .tit'"` �,rl .,n 6 t . , For moro information on-CertainTeed Commercial Roofing Products go to www.coi•tainteod.com_ Caution:CertoinTeed.Flintiastic roofing products are intended.far'Use by professional roofing contractors only. It is the responsibility of the installer to follow all appropriate and required safety.precautions in conjunction with the installation of any CertainTeed roofing product. Meets or exceeds ASTM 06164(SA Mid Ply and SA Cap),ASTM D6163(SA Cap FR)and ASTM D4601(SA NaIlBase and PlyBase). �+('0 in.::f r[61.t+Ilapa 11'r 4,11x.. t,rmmn ssvrnlc.0 _ . i�Ui�) in,. lrni+a,unlp Y Ir‘1.1pn._-a I,rol., J in ih ,0+•• .0' 1• I(( I:S I::S12-I?88 UI n.M1 im1,Moro is mid i.riictir,1it T:vy. AFflillgi • ASK ABOUT ALL OF OUR OTHER CERTAINTEED'' PRODUCTS AND SYSTEMS: CertainTeed Corporation 20 Moores Road ROOFING • SIDING :• TRIM • DECKING" • RAILING FENCE Malvern,PA 19355 GYPSUM • CEILINGS • INSULATION Professional:800-233-8990 www.certainteed.com http://blog.certainteed.com Consumer:800-782-8777 C 2015 CertainTeed corporanon,Pnnind in U.S.A. Cado No COMM-129 ._,.__._—.._,_....,. �.3�'yet: ... { A€NT_GOBAIl�!