Loading...
1611 OCEAN BLVD - ROOF , ,,.:11.J.11.1.1.1,, (,...._ \ CITY OF ATLANTIC BEACH c) 800 SEMINOLE ROAD -i-.51",, r ATLANTIC BEACH, FL 32233 � ,3 ~ � =)' INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF17-0033 Description: remove shingles & modified coating in drain areas Estimated Value: 9850 Issue Date: 10/5/2017 Expiration Date: 4/3/2018 PROPERTY ADDRESS: Address: 1611 OCEAN BLVD RE Number: 169555 0000 PROPERTY OWNER: Name: CALDWELL TOD R III Address: 1659 HERTFORD RD CHARLOTTE, NC 28207 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: BRC Roofing & Construction, Inc. Address: 3938-1 Sunbeam Road JACKSONVILLE, FL 32257 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. 1-m-r City of Atlantic Beach APPLICATION NUMBER ys �l Building Department (To be assigned by the Building Department.) <.?.� 800 Seminole Road V--00E-11-o _oo fit? �� Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 I � E-mail: building-dept@coab.us Date routed: 0 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 11D 11 °U-Ct-() BMA • Department review required Yes No n 9-06q- N5 - (� (1 .�` ildin. Applicant: 1J Q— . \KBD qir or W��ll� cAoi) Planning &Zoning 1 Tree Administrator Project: k tri\ 1_S ,QS a-(h PCCR Qd Public Works ou_1 n� ; n r� � �Q S Q%�� Public Utilities �1 � Public Safety %A•' ck•t Q4 (vt C1 -t \ Fire Services Review fee $ 'prat Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. v Denied. ❑Not applicable (Circle one.) Comments: UILDING PLANNING &ZONING /' Reviewed by: Date: /7 TREE ADMIN. Second Review: Wpproved as revised. ❑Den d. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES p PUBLIC SAFETY Reviewed by: Date: 72 / 1 7 FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ,, r " r),,f\ (E� Ii�1 , �f �� N �� E II 1 1 CITY OF ATLANTIC BEACH �`� J i 800 Seminole Road -511 _r:), r SEP 2 2 2017 ''I ? Atlantic Beach,Florida 32233 \ Lir 11, ; J e REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS ?-00 I 1---003 3 Date q/0707 Revision to Issued Permit, Corrections to Comments)1 Permit# Project Address / b /( OC2e/yt, 6 ) v" Contractor/Contact Name J-erZJ 7 j C ger .L Phone '16 3-1 y (2 Email J-efr 7 a t 6/ c Y-Gr/i. (. 77.-t. Description of Proposed Revision/ orrections: Permit Fee Due .SC',40 Pr,o ,C 2' , s 4) ,v, ..� S7,�� s as- 7ns s7J 7 a ( /071. Additional Increase in Building Value $ a Additional S.F. By signing below,I Je/2/2-y ,-� affirm the Revision is inclusive of the proposed changes. (printed name) QC/vefi e- �'- 22-f`7 Signa e of C ntractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved X Denied Not Applicable to Department Revision/Plan Review Comments De artment Review Required: Buildingfri Planning Zoning Reviewed By Tree Administrator Public Works Public Utilities 7 .2 ? •/7 Public Safety Date Fire Services el)' s CITY OF ATLANTIC BEACH ,. "' 800 SEMINOLE ROAD 1 OFFICE C O PyTLANTIC BEACH,FL 32233 (904)247-5800 r\' (`f. \JJi1 BUILDING DEPARTMENT REVIEW COMMENTS Date: 9.5.2017 Permit#: ROOF17-0033 Site 3938-1 Sunbeam Rd,JAX Site Address: 1611 Ocean Blvd. Addres Review: 1 s: RE#: 169555-0000 Phone: 904-288-0431,904-463-2952 Email: Brcroofing&constructionierry(a,brcr oof.com Applic BRC Roofing& Construction,Inc. Homeo Christina Caldwell, ant: wner: ccaldwe113@me.com C 0 'el CTION COMMENTS: The Product Approval Number submitted for your roof permi as 56 pages of information. The Building Department now does plan review on non shingled roofs. Please re-submit the information from that 56 page document that pertains to the materials used for this repair. Please highlight the materials and the steps of installation,deck application types, base coat, cap sheets,fastener patterns, etc.,2 copies please. R-e c 9 ,22. 1-2 Mike Jones I'h Building Inspector/Plan Reviewer City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 Fax (904) 247-5845 &rnm ,fed Pia il P..v,-e .. (0 vle• VI"0w Ps 9 •S. n "1 Z 70y ?5'3 3/ K9 1 OFFICECOPY BUILDING PERMIT APPLICATION — CITY OF ATLANTIC BEACH Cell ( �3-,2-/cot Seminole Road,Atlantic Beach,FL 32233 (,fl _l Office(904)247-5826 Fax(904)247-5845 Job Address: 1611 Ocean Blvd.,Atlantic Beach FL Permit Number: F 0 OF t -1/� /�— `�033 Legal Description 15-82 09-2S-29E Ocean Grove Unit 1 S/D PT Lot 7 Parcel#169555-0000 --7 �j ,e- Floor Area of Sq.Ft. Sq.Ft Valuation of Work$ gr? 5f./ Proposed Work .)heated/coded/E non-heated/cooled Class of Work(circle one): New Addition I Alteration, Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(drele one): — Commercial Res._, -.p�} •If an existing structure,is a f sp rinklersystem installed?(Circle one): No /A Florida Product Approval# ea 5-4', / For multiple products use product approval form Describe in detail the type of work to be performed:Roof Replacement " Shy a-, , _-%c Z4 C'ezc-N*i 14/1. (2 6/'-tet,, , a-t. ..-, c4AA,, O 3 A fiLG� Property Owner Information: Name:Christina Caldwell Address:1659 Hartford Rd. City Charlotte State.1MZip 28207 Phone 704-953-3169 �� E-Mail or Fax#(Optional) /i. t2 ' , e ..• t t•' - , !.r �ullA�/1'Py, � _ , /Z.0 " --/" Cc4 Contractor Information: Company Name:BRC Roofina&Construction.Inc. Qualifying Agent:Jerry Rowe Address:3938-1 Sunbeam Rd. City Jacksonville State_FL Zip 32257 Office Phone 904-288-0431 lob Site/Contact Number 904-463-2952 Fax#904-292-9390 State Certification/Registration# CCC056398 Architect Name&Phone it EngirreniiiiiHrune# C-(4347.Holder Name and Address £'1 f..ttiCo l� iii/7 Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the wart and inualladass as indicated I cerrij that no wont or instillation has cononenced prior to the issuance o!a permit and that all work will be performed to meet the standards ofall laws regulating construction in this jurisdiction. This permit becomes null and void,T work is not commenced within sit(6J months,or tf consauc ion or work is�uwerrded or abandoned for a prod ofsis(6)months at arty time ager wort is commenced I understand that separate permits must be secured for .rttYrtc Work,Ptrsn4t g,Signs,Wells,Pools,Furnnam,Boilm,Healers, Tants aadA6 C.on&darsen,etc WARNING TO OWNER:YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I hove read and examinedthis implication and know the same be true and comet.AB provisions of laws and ordinances governing this type of work will be complied with w tym/ed herein or not a permit does not presume to give authority to nal to or cancel the provisions of any federal.state,w lar or ormanae ofconstrucrton Signature of 1 1 ' Signature of Contractor C �� 1 Print Name ( V rk If Print Name je i26 - - Swo : d su t . r y •e Sw r•d and subscribed bd.• me cis e.yof ,i$r 'LIG t �'� this._ �. � . : • .20 /7 '�rta�pp t 1T' i•tr■..filtt 4..,'Mfir' Tom.°' b rc 'I ‘ - .1,71711:7„ rc /40" `0111111//ill Revised 01.26.10 �•�' •(NEY _, 'ice :�*"%y S.BRIAN HYNES �OOJ o issia,2 "9C -0 *•.t!' •_= MY COMMISSION#FF055564 V Fl y ��`",j EXPIRES December 17,2017 OTA m � Floridallotaryservice.com m A to (� = (407)39WU153 C� UBL\G 2 \ (��� � t �i «,,,,� 72-2022 C1�•`�`. nn ili.--)7-----7— in II It AUG292017 ll i ill III 1 OFFICE COPY ROOF/ /�/ �7 NOME OF CONUMENCBRENT Permit/4o. Y�o. ao F/ ( - CD 3 3 Tax Folio Na Stam of Florida County of Duval To whom it may concern: The undersigned hereby informs you Mat improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following Information is stated In this NOTICE OF COMMENCEMENT. Legal description of property being unproved 15-82 09-2S-2K Ocean Grove Unit 1 SID PT Lot 7 Lots 15,16 BLK 1 2 OC 1611 Ocean Blvd.,Atlantic Beach,FL 3223:1 Address of property being Improved:1611 Ocean Blvd. General description of improvements Roof Replacement Owner Christine Caldwell Address 1659 Hertford Rd..Charlotte.NC 2$207 Owners Interest En site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor: BRC Roofing&Construction.Inc. Address 11250 Old St.Auaustine Rd.#15313.Jacksonville.FL t2257 Phone No.904-288-0431 Fax No.904-292-9390 Surety CK am) Address Amount of Bond$ Phone No. Fax No. Name and address of any person making a long for the construction of the improve Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other doaunerns may be served: Name Address Phone No. Fax No. in addition to himself,owner designates the following person to receive a copy of the Lierwr•s Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill In at Owners option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a efferent date is specified): THIS SPACE FOR RECORDER'S USE ONLY Before me. 1.1 In the County s ySY1�A of •:,-(l1 OIL has personalyappeared herein by trimseff/icetsetf and affbm that all.•:,> :., and declaration herein are true and accurate. 1‘ '101).‘ '� 14 Notary Public at lame, �- . County oi u 1 I vl l 2 )r•1 My Commission exp :. let i JJ Pe "K`w.n' • n Q ire) Produceasses d FdemffinUrt� ,,)Mf),,, Cge./ i O ,..sro Slob 90 „ � V cy�OTgq� myn _ Doc#2017202848 OR BK 18106 Page56. Number Pages: 1 0 oAt/BL\C' H 2 Recorded 08/29,'2017 at 03:04 PM, i �� '9,12.2022 Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY ,'�i<:)L, 2-2 G°\'‘‘‘•‘- RECORDING$10.00 �iq/1111110�` OFFICE COPY Q1CRINITY!ERD TABLE 1F-2: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER System Deck(Note 1) Base Sheet Roof Cover(Note 14) MDP No. Type Fasten Attach Base Ply Cap (Psf) SELF-ADHERING BASE PLY: Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-inch o.c.in 4-inch lap and 12-inch o.c.in two SBS-SA,APP-SA,SBS- W-136 inch plywood (poly-film top) or Trufast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows SBS SA TA,APP-TA -52.5' W-137 Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-inch o.c.in 4-inch lap and 12-inch o.c.in two Polyflex SA Base APP-TA -52.5' inch plywood (poly-film top) or Trufast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows W-138 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-inch o.c.in 4-inch lap and 12-inch o.c.in two 585 SA SBS-SA,APP-SA,SBS- 60.0" inch plywood (poly-film top) (2),equally spaced,staggered center rows TA,APP-TA W-139 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-inch o.c.in 4-inch lap and 12-inch o.c.in two Polyflex SA Base APP-TA -60.0' inch plywood (poly-film top) (2),equally spaced,staggered center rows TABLE 1G:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(Note 1) Primer Roof Cover(Note 14) MDP(psf) No. Joint Treatment Base Ply Ply Cap Ply Min.15/32- None None -90.0 inch plywood SBS-SA TAPSBS-SA,SBS-APP TATASSA,BAPP TA SBS- W-140 Min.15/32- W-141 inch plywood (Optional)PG100 None Polyflex SA Base (Optional)APP-TA APP-TA -90.0 W-142 Min.15/32- PG100 None inch plywood SBS-SA TAPAPP-TA SBS-SA,SBS- TASAPP TA APP-SA,SBS- -97.5 W-143 Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- W-143 plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA -97.5 W-144 Min.15/32- WB-3000 None SBS-SA,APP-SA,SBS- SBS-SA (Optional) -105.0 inch plywood TA,APP-TA Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,565- SBS-SA,APP-SA,SBS- W-145 inch plywood (Optional)PG 100 -135.0 place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into W-146 inch plywood (Optional)PG100 place to create continuous bond. Polyflex SA Base (Optional)APP-TA APP-TA -135.0 Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R19 for FL1654-R21 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 19:05/30/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 21 of 56 f OFFICE COPY mc DESo7. Installation Guide for Self-Adhered Membranes POLYGLASS®USA, Inc. Corporate Office1410 1 1 1 1 West Newport Center Drive • Deerfield Beach,Florida 33442 ' Phone(954)233-1330-Fax(954)418-4453I,� .- Toll Free(888)410-1375 ,k , 4 .L.e-mail:pgmarketing@polyglass.com ! Manufacturing Facilities ` Fernley, Nevada 89408 E ,. Phone(775)575-6007-Fax(775)575-2314 0 Toll Free(800)222-9782 v - a Hazleton,Pennsylvania 18202 H t ~` Phone(570)384-1230-Fax(570) 384-3282 V7F ' Toll Free(800) 894-4563 F, ,.. " Winter Haven,Florida 33880 Phone(863)297-5800-Fax(863)618-2193 Toll Free(866) 802-8017 0 a •R a Rs r G ito -, F c veil WATERPROOFING MATERIALS AND INSULATING SYSTEMS-, i [ POLYGLASS 0 0 ATEEPEGOPIED MATERIALS AND UEDLATIEG SYSTEMS L=111M11 R . POLYGLASS Q �p. Y ' ����oEsoi Installation Guide .rEv- AWAPEo awS9140.oar PGSA32_ADESO5 SA ROOF DRAIN DETAIL - F. ALTERNATE ` Oran strainer , • Cast ion clamping m9 30"square mnenum,lead a 16 oz. copper taring set in tooled Poyglass PG 500 F sealant pine top surface before stripping Poyglaas EIASTOFIA SA roofing membranes (2 plies,SA V o 1 py SA P) , NO Poyglass SA multiple-ply roof membrane system ... �. SURFACE PREPARATION & PRECAUTIONS xugnuuuu I r/ ADESO self-adhered membranes are to be applied directly :% ''' :IIIIIIIIIIIIII.111111111111111llllllllltllumt to approved insulations, Polyglass base sheets, and roof :�� decks. Do not apply to shingles,shakes or other residential mmlihfinished roof coverings. sp '4� 1.Apply only when the weather is dry and all material tii�M.. interface temperatures(air, roof deck,membrane)are 40 Tapered insulation degrees F(5 degrees C) and rising. Roofing installation EusroFD sAP shall not be conducted when water is in any form i.e.rain, me,,oranefieyd metal dew, ice, frost, snow. Use of hot air gun or SBS cold Ilasnig andsbgpng plias adhesive,may be required under low temperature conditions. all extend under clempng rig Drain bowl Roof deck 2.All roof deck application areas shall have positive Thereof insulation Under deckdamo drainage, continuous support and structurally sound to support the live and dead load requirements of the roofing Coverboardisaation,wherereQ,,,d system and sufficiently rigid to support construction traffic. Notes: 3.Apply only over clean, dry and dust-free surfaces. For best results, wood, concrete, masonry, metal or metallic 1. Attach wood nailer to wall/deck in accordance with surfaces and acceptable smooth surface BUR and other ANSI/SPRI ES-1. acceptable substrates are to be primed with Polyglass PG 2. Wood blocking may be slotted for venting of wet-fill decks 100 Asphalt Roof Primer prior to the application of the or other applicable constructions. membrane. The primed substrate should be fully dry prior 3. This detail should be used only where the deck is supported to installation. by the outside wall. 4. Refer to SMACNA recommendations & details regarding 4.Masonry or concrete supported by steel frame or other metal thickness&cleat requirements. steel structure shall be provided with suitable expansion 5. Membrane endlaps must be 6"minimum&fully adhered to joint designs and detailed for movement. all membrane in all locations where FASTLap is not present. 5. Ensure that installation of any ADESO self-adhered STORAGE product does not prevent or interfere with ventilation of existing construction. ADESO self-adhered membranes should be stored at room temperature whenever possible.Avoid storing out of the box for prolonged periods. Do not take the roll out of the box until it is ready for application. Do not store unpacked roll in direct sunlight and in bright sunshine or in hot weather. Removal of release film may cause static electricity discharge. 0 Details I General Recommendations General Recommendations ����PFSO/° Installation Guide ,rE�„��►sererrso/7•1199010.(00,1" SEAMING DETAIL FOR ELASTOFLEX SA P or SEAM INTERSECTION TREATMENT-FLASHINGS POLYFLEX SA P PLAN VIEW OF Step 1. TOP ROLL 45°ANGLE CUT FASTLap ROLL-END SELVAGE AT SHEET CORNERS& HOLYGLASsPG500 PRIMED SUBSTRATE' °",;-- 4 OR FEAR WELD ELASTOFLEX SAV BASE ---',Fr. ` or OTHER ACCEPTED [ BASE SHEET K,..-.1.1.4:,r STEP i POLYGLASS PG 600 SBS EG.ANGLE C APPCUTIEDS]Al---------- T . / OR HEAT WELD PROTECTIVE SEAM TAPE SEALLap se [TO BE REMOVED PRIOR TO SEAMING) ! PREVIOUSLY INSTALLED SHEET or ROLL SEAM INTERSECTION TREATMENT-FIELD :acw.,..e-.a sos.. n STEP 2 110000000 ^'4` _ '7 y4 ,..� f 1 ''':34%,,),N,:v,,, ''i.r.' sh.2 . erw:d 45 DEG.ANGLE CUT AT SHEET CORNERS& % Mk Provide POLYGLASS POLYGLASS PO500 appm detail ter- 1IP OR HEAT WELD Sa.Mt.. wpox /a.WO mination,as required by tbn for _= Sequence: 4 / A.Sheet 1 is applied to substrate. ELASTOFLEX SAP / B.Triangle piece of approx.45°are cut off at the bottom corner of field membrane / sheet 2 (usually at the FASTLap end of the sheet)and at the top cornerELAof sheet 3(the side lap selvage edge SEALLap). base sh et SA V base sheet C.Sheet 2 is aligned&applied to the substrate. Approved substrate D.A bead of Polyglass PG 500 SBS mastic is applied at the angle cuts(see inset)or heat weld. E.Sheet 3 is applied. F.Top sheet is carefully rolled parallel to both sides of the sealant Refer To Nobs On Pay.16 not on the sealant. Nob: The angle cut&seam sealant Is to be applied at all self-adhered sheet overlaps(base&cap) 0 Details Details 0 • • /i��DFSO Installation Guide de-077.0,-.447A6911197nrs�.rrwawr DO's ELASTOFLEX SA V Base 1. DO prime all concrete,masonry,metal or metallic surfaces adhered to deck and over nailer, below edge metal.This is 2. DO apply to clean,dry,dust free surfaces an alternative for 2 ply(or more) 3. DO remove split release film at a 90 degree angle systems.The starter strip netlwd 4. DO roll all seams SEALLap and FASTLap to ensure 100%adhesion shown in Step 1 is for one-ply application only. 5. DO reinforce all in/out side corners Deck 6. DO back nail head laps whenever roof pitch is over 2-1/2:12 Roof nails substrate (staggered 4") 7. DO roll membrane when finished 8. DO keep material cool in summer "1"• 9. DO keep material warm in winter Drip edge(fastened in 10.DO sandwich all metal flashing components accordance with all local---, building codes) STEP 2 DON'Ts 1. DO NOT apply roofing membrane during inclement weather 2. DO NOT take ADESO roll out of box until ready to apply 3. DO NOT apply over shingles or similar roof coverings ELASTOFLEX SA V 4. DO NOT store in direct sunlight Strip-in 9"wide minimum,stop 1/2"from outside edge of metal 5. DO NOT apply to a dirty,wet,dusty substrate 6. DO NOT leave out of the box overnight. Stage only a few rolls in ELASTOFLEX SA P or POLYFLEX SA P advance and use all rolls removed from packaging on the same day. membrane installed over SA V Base 7. DO NOT apply in cold or wet weather or when moisture is on strip and onto primed metal. deck(material substrate and ambient temperature should be at aVv- least 40 degrees F(5 degrees C)and rising) 8. DO NOT forget to angle at 45 degrees on buried laps 9. DO NOT forget to lap 6"on granular to granular overlaps —' STEP 3 TYPICAL ROOF EDGE DETAIL ELASTOFLEXSAV starter strip cut to reqd.width,adhered to deck. Nobs: Insure the polyolefin"top film"is clean and dust free in order to A. Factory endlaps are provided with Polyglass proprietary FASTLap achieve the best adhesion of the following plies. feature.These laps can be sealed in the usual way. At"BONDING Note: For 2 or more ply systems see Step 2. AREAS"where a seam MUST be made to the granular surface,the following alternatives are acceptable: Alternatives at Bonding area: Deck primed with asphalt primer 1. Granular area heated to further embed granules into SBS or APP (where required)-or accepted compound before installing subsequent flashing piece insulation attached to deck 2. Heat weld subsequent flashing seams with hot-air gun or mini-torch 3. Granular endlaps must be a 6" Mininum & FULLY ADHERED.This 9-12'(may vary can be achieved by carefully applying POLYPLUS 35 + SBS Ref.Chalk kne MODIFIED TROWEL ADHESIVE in the 6" overlap area before joining the seam surfaces To prevent unsightly surplus adhesive on the visible area,mask the endlap temporarily with the tape and remove when the adhesive is dry. STEP 1 B. Ensure adhesion is achieved at all metal surfaces by priming with D41 Asphalt Roof Primer and providing a 3"min.overlap. Do's&Doers Details 7w4�oEso/ Installation Guide otn rso 1rcwoorrarrwr 9.Application A. Details are carried out by using a hot-air welding mastic technique or Polyglass PG 500 SBS TROWEL Grade. • B.Heat should be applied with a flameless torch or hot-air welder Open flame torches are not recommended. ;r t • ' orP I/ 8.Application A.After adhering rolls it is required that uniform pressure be applied to the entire sheet area by using an 80 lb +' (minimum)linoleum roller,water filled lawn roller or similar weighted roller in a method suitable to the roof slope. R ' Care must be taken to prevent injury when rolling membrane,especially on sloped surfaces. �'i... 9 • 44 are 9 44111111 110401 0 Applicationf Applications 411) � ��D7$OJ' Installation Guide ..$1.7"-AOW4'I 7ElWA' ) 3.Application 5.Application A.Fold the aligned membrane in half, exposing the dual A.At seam overlaps,align next sheet of application,fold sheet release filmback and remove split release film. Remove, from the B. Peel release film at a 90 degree angle in a constant motion installed roll,the protective tape,SEALLap and apply even ensuring to keep weight on the outer edges, as you pressure to the self sealing SEALLap area,while overlapping progress. Position the next sheet by overlapping seams the next sheet. and line up the overlap of the top sheet edge with the inside of the bottom sheet's factory selvage SEALLap edges. Overlap and cut end laps minimum 6". C. This is only one example of an application technique; contractors may develop their own methods of application. . • w rf' . . rist r PK 0.ri ._._ . . • •s.4 --rf-- . . --4441 a k 6.Application A. Roll seams and edges firmly with a steel or other suitable -11111 A roller to ensure full adhesion. + 3 1 .r itF 7 psi 4.Application 1 A.Press the membrane Into place with firm,even pressure. Yr.,.:; ',. Wirallir 't i 6 . i it . at- 7.Application A. Applications on a slope greater than 2-12"to 12"need to be back nailed in the seams overlap with ring shanked metal 4 capped roofing nails,6"o.c. 0 Applications Applications 0 f ' /M1410750/ .Installation Guie �.ios�srEo ix-.suaouaor e APPLICATION INSTRUCTIONS 1.Application A. Remove existing materials and obsolete penetrations ., down to an acceptable substrate, repair any voids or '' 01 ,.- imperfections in the substrate. +%- B. For steep-slope underlayments, cut the 2-square rolls into a minimum of 3 equal sections. /, . ,• i C.Unroll and allow membrane to relax in the sun for a recom- . mended 15 minutes prior to installation in final location. wot."/- yam''. _.,.�-y-tr r ..._ i ... w Nee' Tools 1. Trowel 2. Caulking Gun • ..„ _ 3. Metal Head Hand Roller 4. Tape Measure 5. Utility Knives-Hook Blade,Straight Blade 6. Claw Hammer 1 7. Tin Snips 8. Hand Held Hot Air Welder 9. Silicone Hand Held Roller 2.Applicatior, A.Measure leading edge for width of first sheet and snap straight -1 , , chalk line. B.Lay the material flat in place,starting at the lowest point. r� .. J C.Align the membrane with chalk line at the lowest edge of "` the roof. Ps Soo "_' D.Install in shingle fashion from lowest point to highest point on roof. dit Accessories r_ - 1. Polyglass PG 500 TROWEL Grade Mod-Bit Adhesive- 10.3 oz cartridge • 2.Polyglass PG 500 TROWEL Grade Mod-Bit Adhesive- 4.75 gal.Pail 3.Polyglass PG100 ASPHALT PRIMER- 14 oz spray Can 4.80 lb(minimum)linoleum roller i 0 Tools&Accessories Applications CI • / o7SOJ'e Installation Guide ��o ntism4araor FASTLap means increased productivity i i. FASTLap provides a patented granule-free roll end feature. r0. The release film is clean and simple to remove. Minimizing the ir `‘. effort and time required to achieve a perfect end seam. al I 1ff.selvage release film 1 ,, 2.Surfacing(granules/sand •EASYBOX is precut on one side of the box. 3.Factory applied adneewe treatment •Easy removal of roll from side of the box-no more strain from lifting the roll out of the box. SEALLap quick waterproofing of side laps • This is a unique patent-pending,factory-applied treatment on the side lap of rolls to enhance sealability. • Advantages:Instant and Permanent bond between adjacent membranes, even under low temperature conditions. Cost kirehisri j / Savings.No need for use of external caulk or mastics to ensure lap bond. Labor Savings. Factory applied adhesive on the el. selvage areas translates to less time to install roofing membrane. Environmentally friendly. No need for external • Easy folding process-the box is already flat-no more mastics or heat,as required by competitors'membranes. work wasted breaking down boxes. •Easy stacking of flat boxes creates simple disposal-an end ACCEPTABLE SUBSTRATES to scattered boxes littering your jobsite. Acceptable substrates for ADESO self-adhered applications: FASTLap Enhanced End Laps -Polyisocyanurate The sealing of the end lap between two rolls of granular -GP Densdeck Prime(pre-primed board must still be primed) modified bitumen membranes has long been an arduous and DuraGuard®USG SecureRock• troublesome operation. If granules are not heated and -Asphalt impregnated,six-sided Woodfiber Board embedded satisfactorily, a reliable and durable seam may -Primed Concrete not be achieved. If the granular areas are overheated, the reinforcement may warp, be damaged or loss of modified -New Plywood Decking or Primed Existing Plywood adhesive may occur. -Joints must be taped(When in doubt,prime) Polyglass Elastobase®Poly/Sand-Base sheet,mechanically f i t r attached,heat welded or set in hot asphalt II\ Polyglass Elastoflex•SA V Base-Base sheet /// l Notes: ){ f Polyglass recommends the use of Polyglass PG 500 mastic j. \ and Polyglass PG 100 Asphalt Primer. A`"a Contact Polyglass Technical Services for suitability of other Isauapl IrAgnaP1 equal items at(866)802-8017. 0 Special Features FASTLap&SEALLap I Acceptable Substrates 0