1611 OCEAN BLVD - ROOF , ,,.:11.J.11.1.1.1,,
(,...._
\ CITY OF ATLANTIC BEACH
c) 800 SEMINOLE ROAD
-i-.51",, r ATLANTIC BEACH, FL 32233
� ,3
~ � =)' INSPECTION PHONE LINE 247-5814
ROOF NON SHINGLE -
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: ROOF17-0033
Description: remove shingles & modified coating in drain areas
Estimated Value: 9850
Issue Date: 10/5/2017
Expiration Date: 4/3/2018
PROPERTY ADDRESS:
Address: 1611 OCEAN BLVD
RE Number: 169555 0000
PROPERTY OWNER:
Name: CALDWELL TOD R III
Address: 1659 HERTFORD RD
CHARLOTTE, NC 28207
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
Phone:
Name: BRC Roofing & Construction, Inc.
Address: 3938-1 Sunbeam Road
JACKSONVILLE, FL 32257
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
1-m-r City of Atlantic Beach APPLICATION NUMBER
ys �l Building Department (To be assigned by the Building Department.)
<.?.� 800 Seminole Road V--00E-11-o _oo
fit? �� Atlantic Beach, Florida 32233-5445
Phone(904)247-5826 • Fax(904)247-5845 I �
E-mail: building-dept@coab.us Date routed: 0
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 11D 11 °U-Ct-() BMA • Department review required Yes No
n 9-06q- N5
- (� (1 .�` ildin.
Applicant: 1J Q— . \KBD qir or W��ll� cAoi) Planning &Zoning
1 Tree Administrator
Project: k tri\ 1_S ,QS a-(h PCCR Qd Public Works
ou_1 n� ; n r� � �Q S Q%�� Public Utilities
�1 � Public Safety
%A•' ck•t Q4 (vt C1 -t \ Fire Services
Review fee $ 'prat
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. v Denied. ❑Not applicable
(Circle one.) Comments:
UILDING
PLANNING &ZONING /'
Reviewed by: Date: /7
TREE ADMIN. Second Review: Wpproved as revised. ❑Den d. ['Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES p
PUBLIC SAFETY Reviewed by: Date: 72 / 1 7
FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
,, r " r),,f\ (E� Ii�1 , �f �� N �� E II
1 1 CITY OF ATLANTIC BEACH
�`� J i 800 Seminole Road
-511
_r:),
r SEP 2 2 2017 ''I ? Atlantic Beach,Florida 32233
\ Lir 11,
; J
e
REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS
?-00 I 1---003 3
Date q/0707 Revision to Issued Permit, Corrections to Comments)1 Permit#
Project Address / b /( OC2e/yt, 6 ) v"
Contractor/Contact Name J-erZJ 7 j C ger .L
Phone '16 3-1 y (2 Email J-efr 7 a t 6/ c Y-Gr/i. (. 77.-t.
Description of Proposed Revision/ orrections: Permit Fee Due .SC',40
Pr,o ,C 2' , s 4) ,v, ..� S7,��
s as- 7ns s7J 7 a ( /071.
Additional Increase in Building Value $ a Additional S.F.
By signing below,I Je/2/2-y ,-� affirm the Revision is inclusive of the proposed changes.
(printed name)
QC/vefi e- �'- 22-f`7
Signa e of C ntractor/Agent(Contractor must sign if increase in valuation) Date
(Office Use Only)
Approved X Denied Not Applicable to Department
Revision/Plan Review Comments
De artment Review Required:
Buildingfri
Planning Zoning Reviewed By
Tree Administrator
Public Works
Public Utilities 7 .2 ? •/7
Public Safety Date
Fire Services
el)' s CITY OF ATLANTIC BEACH
,. "' 800 SEMINOLE ROAD
1 OFFICE C O PyTLANTIC BEACH,FL 32233
(904)247-5800
r\' (`f.
\JJi1
BUILDING DEPARTMENT REVIEW COMMENTS
Date: 9.5.2017
Permit#: ROOF17-0033 Site 3938-1 Sunbeam Rd,JAX
Site Address: 1611 Ocean Blvd. Addres
Review: 1 s:
RE#: 169555-0000 Phone: 904-288-0431,904-463-2952
Email: Brcroofing&constructionierry(a,brcr
oof.com
Applic BRC Roofing& Construction,Inc. Homeo Christina Caldwell,
ant:
wner: ccaldwe113@me.com
C 0 'el CTION COMMENTS: The Product Approval Number submitted for your roof permi
as 56 pages of information. The Building Department now does plan review on non shingled
roofs. Please re-submit the information from that 56 page document that pertains to the
materials used for this repair. Please highlight the materials and the steps of installation,deck
application types, base coat, cap sheets,fastener patterns, etc.,2 copies please.
R-e c 9 ,22. 1-2
Mike Jones I'h
Building Inspector/Plan Reviewer
City Of Atlantic Beach
800 Seminole Road
Atlantic Beach, FL 32233-5445
Ofc (904) 247-5844
Fax (904) 247-5845
&rnm ,fed Pia il P..v,-e .. (0 vle• VI"0w Ps 9 •S. n "1 Z
70y ?5'3 3/ K9
1
OFFICECOPY BUILDING PERMIT APPLICATION —
CITY OF ATLANTIC BEACH Cell ( �3-,2-/cot
Seminole Road,Atlantic Beach,FL 32233 (,fl _l
Office(904)247-5826 Fax(904)247-5845
Job Address: 1611 Ocean Blvd.,Atlantic Beach FL Permit Number: F 0 OF t -1/� /�— `�033
Legal Description 15-82 09-2S-29E Ocean Grove Unit 1 S/D PT Lot 7 Parcel#169555-0000
--7
�j ,e- Floor Area of Sq.Ft. Sq.Ft
Valuation of Work$
gr?
5f./ Proposed
Work
.)heated/coded/E non-heated/cooled
Class of Work(circle one): New Addition I Alteration, Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s)(drele one): — Commercial Res._, -.p�}
•If an existing structure,is a f sp rinklersystem installed?(Circle one): No /A
Florida Product Approval# ea 5-4', /
For multiple products use product approval form
Describe in detail the type of work to be performed:Roof Replacement " Shy a-, ,
_-%c Z4 C'ezc-N*i 14/1. (2 6/'-tet,, , a-t. ..-, c4AA,, O 3 A fiLG�
Property Owner Information:
Name:Christina Caldwell Address:1659 Hartford Rd.
City Charlotte State.1MZip 28207 Phone 704-953-3169 ��
E-Mail or Fax#(Optional) /i. t2 ' , e ..• t t•' - , !.r �ullA�/1'Py, � _ , /Z.0 " --/" Cc4
Contractor Information:
Company Name:BRC Roofina&Construction.Inc. Qualifying Agent:Jerry Rowe
Address:3938-1 Sunbeam Rd. City Jacksonville State_FL Zip 32257
Office Phone 904-288-0431 lob Site/Contact Number 904-463-2952 Fax#904-292-9390
State Certification/Registration# CCC056398
Architect Name&Phone it
EngirreniiiiiHrune# C-(4347.Holder Name and Address £'1 f..ttiCo l� iii/7
Bonding Company Name and Address
Mortgage Lender Name and Address
Application is hereby made to obtain a permit to do the wart and inualladass as indicated I cerrij that no wont or instillation has cononenced prior to the
issuance o!a permit and that all work will be performed to meet the standards ofall laws regulating construction in this jurisdiction. This permit becomes null
and void,T work is not commenced within sit(6J months,or tf consauc ion or work is�uwerrded or abandoned for a prod ofsis(6)months at arty time ager
wort is commenced I understand that separate permits must be secured for .rttYrtc Work,Ptrsn4t g,Signs,Wells,Pools,Furnnam,Boilm,Healers,
Tants aadA6 C.on&darsen,etc
WARNING TO OWNER:YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
I hereby certify that I hove read and examinedthis implication and know the same be true and comet.AB provisions of laws and ordinances governing this
type of work will be complied with w tym/ed herein or not a permit does not presume to give authority to nal to or cancel the
provisions of any federal.state,w lar or ormanae ofconstrucrton
Signature of 1
1 ' Signature of Contractor C ��
1
Print Name ( V rk
If Print Name je i26 - -
Swo : d su t . r y •e Sw r•d and subscribed bd.• me
cis e.yof ,i$r 'LIG t �'� this._ �. � . : • .20 /7
'�rta�pp t
1T' i•tr■..filtt 4..,'Mfir'
Tom.°' b rc 'I ‘ - .1,71711:7„ rc /40"
`0111111//ill Revised 01.26.10
�•�' •(NEY _, 'ice :�*"%y S.BRIAN HYNES
�OOJ o issia,2 "9C -0 *•.t!' •_= MY COMMISSION#FF055564
V Fl y ��`",j EXPIRES December 17,2017
OTA m � Floridallotaryservice.com
m A to (� = (407)39WU153
C� UBL\G 2
\ (��� � t �i «,,,,� 72-2022 C1�•`�`.
nn
ili.--)7-----7—
in II
It AUG292017
ll i
ill
III
1
OFFICE COPY
ROOF/
/�/ �7 NOME OF CONUMENCBRENT
Permit/4o. Y�o. ao F/ ( - CD 3 3 Tax Folio Na
Stam of Florida County of Duval
To whom it may concern:
The undersigned hereby informs you Mat improvements will be made to certain real property,and in accordance with Section
713 of the Florida Statutes,the following Information is stated In this NOTICE OF COMMENCEMENT.
Legal description of property being unproved 15-82 09-2S-2K Ocean Grove Unit 1 SID PT Lot 7 Lots 15,16 BLK 1 2 OC
1611 Ocean Blvd.,Atlantic Beach,FL 3223:1
Address of property being Improved:1611 Ocean Blvd.
General description of improvements Roof Replacement
Owner Christine Caldwell
Address 1659 Hertford Rd..Charlotte.NC 2$207
Owners Interest En site of the improvement
Fee Simple Titleholder(if other than owner)
Name
Address
Contractor: BRC Roofing&Construction.Inc.
Address 11250 Old St.Auaustine Rd.#15313.Jacksonville.FL t2257
Phone No.904-288-0431 Fax No.904-292-9390
Surety CK am)
Address Amount of Bond$
Phone No. Fax No.
Name and address of any person making a long for the construction of the improve
Name
Address
Phone No. Fax No.
Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other doaunerns
may be served:
Name
Address
Phone No. Fax No.
in addition to himself,owner designates the following person to receive a copy of the Lierwr•s Notice as provided in
Section 713.06(2)(b),Florida Statutes.(Fill In at Owners option).
Name
Address
Phone No. Fax No.
Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a efferent date
is specified):
THIS SPACE FOR RECORDER'S USE ONLY
Before me. 1.1 In the
County
s ySY1�A
of
•:,-(l1 OIL has personalyappeared
herein by trimseff/icetsetf
and affbm that all.•:,> :., and declaration herein are true and accurate.
1‘ '101).‘ '� 14
Notary Public at lame, �- . County oi u 1 I vl l 2 )r•1
My Commission exp :. let i JJ
Pe "K`w.n' • n Q ire)
Produceasses d FdemffinUrt� ,,)Mf),,,
Cge./ i
O ,..sro Slob 90 „
� V
cy�OTgq� myn _
Doc#2017202848 OR BK 18106 Page56.
Number Pages: 1 0 oAt/BL\C' H 2
Recorded 08/29,'2017 at 03:04 PM, i �� '9,12.2022
Ronnie Fussell CLERK CIRCUIT COURT DUVAL
COUNTY ,'�i<:)L, 2-2 G°\'‘‘‘•‘-
RECORDING$10.00 �iq/1111110�`
OFFICE COPY
Q1CRINITY!ERD
TABLE 1F-2: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PLATES),BONDED ROOF COVER
System Deck(Note 1) Base Sheet Roof Cover(Note 14) MDP
No. Type Fasten Attach Base Ply Cap (Psf)
SELF-ADHERING BASE PLY:
Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-inch o.c.in 4-inch lap and 12-inch o.c.in two SBS-SA,APP-SA,SBS-
W-136 inch plywood (poly-film top) or Trufast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows SBS SA TA,APP-TA -52.5'
W-137 Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-inch o.c.in 4-inch lap and 12-inch o.c.in two Polyflex SA Base APP-TA -52.5'
inch plywood (poly-film top) or Trufast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows
W-138 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-inch o.c.in 4-inch lap and 12-inch o.c.in two 585 SA SBS-SA,APP-SA,SBS- 60.0"
inch plywood (poly-film top) (2),equally spaced,staggered center rows TA,APP-TA
W-139 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-inch o.c.in 4-inch lap and 12-inch o.c.in two Polyflex SA Base APP-TA -60.0'
inch plywood (poly-film top)
(2),equally spaced,staggered center rows
TABLE 1G:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Deck(Note 1) Primer Roof Cover(Note 14) MDP(psf)
No. Joint Treatment Base Ply Ply Cap Ply
Min.15/32- None None -90.0
inch plywood SBS-SA TAPSBS-SA,SBS-APP TATASSA,BAPP TA
SBS-
W-140
Min.15/32-
W-141
inch plywood (Optional)PG100 None Polyflex SA Base (Optional)APP-TA APP-TA -90.0
W-142 Min.15/32- PG100 None
inch plywood SBS-SA TAPAPP-TA SBS-SA,SBS- TASAPP TA APP-SA,SBS- -97.5
W-143 Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS-
W-143 plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA -97.5
W-144 Min.15/32- WB-3000 None SBS-SA,APP-SA,SBS-
SBS-SA (Optional) -105.0
inch plywood
TA,APP-TA
Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,565- SBS-SA,APP-SA,SBS-
W-145
inch plywood (Optional)PG 100 -135.0
place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA TA,APP-TA
Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into
W-146
inch plywood (Optional)PG100 place to create continuous bond. Polyflex SA Base (Optional)APP-TA APP-TA -135.0
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R19 for FL1654-R21
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 19:05/30/2017
Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 21 of 56
f
OFFICE COPY
mc DESo7.
Installation Guide
for Self-Adhered Membranes
POLYGLASS®USA, Inc.
Corporate Office1410
1 1 1 1 West Newport Center Drive •
Deerfield Beach,Florida 33442 '
Phone(954)233-1330-Fax(954)418-4453I,� .-
Toll Free(888)410-1375 ,k
, 4 .L.e-mail:pgmarketing@polyglass.com !
Manufacturing Facilities `
Fernley, Nevada 89408 E ,.
Phone(775)575-6007-Fax(775)575-2314 0
Toll Free(800)222-9782
v - a
Hazleton,Pennsylvania 18202 H t ~`
Phone(570)384-1230-Fax(570) 384-3282 V7F '
Toll Free(800) 894-4563 F, ,.. "
Winter Haven,Florida 33880
Phone(863)297-5800-Fax(863)618-2193
Toll Free(866) 802-8017 0
a
•R a
Rs
r G
ito -,
F
c
veil
WATERPROOFING MATERIALS AND INSULATING SYSTEMS-, i
[ POLYGLASS 0 0 ATEEPEGOPIED MATERIALS AND UEDLATIEG SYSTEMS
L=111M11 R . POLYGLASS Q
�p.
Y '
����oEsoi Installation Guide
.rEv- AWAPEo awS9140.oar
PGSA32_ADESO5 SA ROOF DRAIN DETAIL -
F.
ALTERNATE `
Oran strainer , •
Cast ion clamping m9
30"square mnenum,lead a 16 oz.
copper taring set in tooled Poyglass
PG 500 F sealant pine top surface
before stripping
Poyglaas EIASTOFIA SA
roofing membranes
(2 plies,SA V o 1 py SA P) ,
NO
Poyglass SA multiple-ply
roof membrane system ... �.
SURFACE PREPARATION & PRECAUTIONS
xugnuuuu I r/ ADESO self-adhered membranes are to be applied directly
:% ''' :IIIIIIIIIIIIII.111111111111111llllllllltllumt to approved insulations, Polyglass base sheets, and roof
:�� decks. Do not apply to shingles,shakes or other residential
mmlihfinished roof coverings.
sp '4� 1.Apply only when the weather is dry and all material
tii�M.. interface temperatures(air, roof deck,membrane)are 40
Tapered insulation degrees F(5 degrees C) and rising. Roofing installation
EusroFD sAP shall not be conducted when water is in any form i.e.rain,
me,,oranefieyd metal dew, ice, frost, snow. Use of hot air gun or SBS cold
Ilasnig andsbgpng plias adhesive,may be required under low temperature conditions.
all extend under clempng rig
Drain bowl
Roof deck 2.All roof deck application areas shall have positive
Thereof insulation Under deckdamo drainage, continuous support and structurally sound to
support the live and dead load requirements of the roofing
Coverboardisaation,wherereQ,,,d system and sufficiently rigid to support construction traffic.
Notes: 3.Apply only over clean, dry and dust-free surfaces. For
best results, wood, concrete, masonry, metal or metallic
1. Attach wood nailer to wall/deck in accordance with surfaces and acceptable smooth surface BUR and other
ANSI/SPRI ES-1. acceptable substrates are to be primed with Polyglass PG
2. Wood blocking may be slotted for venting of wet-fill decks 100 Asphalt Roof Primer prior to the application of the
or other applicable constructions. membrane. The primed substrate should be fully dry prior
3. This detail should be used only where the deck is supported to installation.
by the outside wall.
4. Refer to SMACNA recommendations & details regarding 4.Masonry or concrete supported by steel frame or other
metal thickness&cleat requirements. steel structure shall be provided with suitable expansion
5. Membrane endlaps must be 6"minimum&fully adhered to joint designs and detailed for movement.
all membrane in all locations where FASTLap is not present.
5. Ensure that installation of any ADESO self-adhered
STORAGE product does not prevent or interfere with ventilation of
existing construction.
ADESO self-adhered membranes should be stored at room
temperature whenever possible.Avoid storing out of the box
for prolonged periods. Do not take the roll out of the box
until it is ready for application. Do not store unpacked roll in
direct sunlight and in bright sunshine or in hot weather.
Removal of release film may cause static electricity
discharge.
0 Details I General Recommendations General Recommendations
����PFSO/° Installation Guide
,rE�„��►sererrso/7•1199010.(00,1"
SEAMING DETAIL FOR ELASTOFLEX SA P or SEAM INTERSECTION TREATMENT-FLASHINGS
POLYFLEX SA P
PLAN VIEW OF Step 1.
TOP ROLL 45°ANGLE CUT
FASTLap ROLL-END SELVAGE AT SHEET CORNERS&
HOLYGLASsPG500
PRIMED SUBSTRATE' °",;-- 4 OR FEAR WELD
ELASTOFLEX SAV BASE ---',Fr.
`
or OTHER ACCEPTED [
BASE SHEET K,..-.1.1.4:,r
STEP i
POLYGLASS PG 600
SBS EG.ANGLE C APPCUTIEDS]Al----------
T . /
OR HEAT WELD
PROTECTIVE SEAM TAPE SEALLap se
[TO BE REMOVED PRIOR TO SEAMING) !
PREVIOUSLY INSTALLED SHEET or ROLL
SEAM INTERSECTION TREATMENT-FIELD
:acw.,..e-.a sos.. n STEP 2
110000000
^'4` _ '7 y4 ,..� f 1
''':34%,,),N,:v,,, ''i.r.' sh.2 . erw:d
45 DEG.ANGLE CUT
AT SHEET CORNERS& % Mk Provide POLYGLASS
POLYGLASS PO500 appm detail ter- 1IP OR HEAT WELD
Sa.Mt..
wpox /a.WO mination,as required
by tbn for _=
Sequence: 4 /
A.Sheet 1 is applied to substrate. ELASTOFLEX SAP /
B.Triangle piece of approx.45°are cut off at the bottom corner of field membrane /
sheet 2 (usually at the FASTLap end of the sheet)and at the top
cornerELAof sheet 3(the side lap selvage edge SEALLap). base sh et SA V
base sheet
C.Sheet 2 is aligned&applied to the substrate. Approved substrate
D.A bead of Polyglass PG 500 SBS mastic is applied at the angle
cuts(see inset)or heat weld.
E.Sheet 3 is applied.
F.Top sheet is carefully rolled parallel to both sides of the sealant
Refer To Nobs On Pay.16
not on the sealant.
Nob:
The angle cut&seam sealant Is to be applied at all self-adhered sheet
overlaps(base&cap)
0 Details Details 0
•
•
/i��DFSO Installation Guide
de-077.0,-.447A6911197nrs�.rrwawr
DO's ELASTOFLEX SA V Base
1. DO prime all concrete,masonry,metal or metallic surfaces adhered to deck and over
nailer, below edge metal.This is
2. DO apply to clean,dry,dust free surfaces an alternative for 2 ply(or more)
3. DO remove split release film at a 90 degree angle systems.The starter strip netlwd
4. DO roll all seams SEALLap and FASTLap to ensure 100%adhesion shown in Step 1 is for one-ply
application only.
5. DO reinforce all in/out side corners Deck
6. DO back nail head laps whenever roof pitch is over 2-1/2:12 Roof nails substrate
(staggered 4")
7. DO roll membrane when finished
8. DO keep material cool in summer "1"•
9. DO keep material warm in winter
Drip edge(fastened in
10.DO sandwich all metal flashing components accordance with all local---,
building codes) STEP 2
DON'Ts
1. DO NOT apply roofing membrane during inclement weather
2. DO NOT take ADESO roll out of box until ready to apply
3. DO NOT apply over shingles or similar roof coverings ELASTOFLEX SA V
4. DO NOT store in direct sunlight Strip-in 9"wide minimum,stop 1/2"from outside edge of metal
5. DO NOT apply to a dirty,wet,dusty substrate
6. DO NOT leave out of the box overnight. Stage only a few rolls in ELASTOFLEX SA P or POLYFLEX SA P
advance and use all rolls removed from packaging on the same day. membrane installed over SA V Base
7. DO NOT apply in cold or wet weather or when moisture is on strip and onto primed metal.
deck(material substrate and ambient temperature should be at
aVv-
least 40 degrees F(5 degrees C)and rising)
8. DO NOT forget to angle at 45 degrees on buried laps
9. DO NOT forget to lap 6"on granular to granular overlaps —'
STEP 3
TYPICAL ROOF EDGE DETAIL
ELASTOFLEXSAV starter strip cut to reqd.width,adhered to deck. Nobs:
Insure the polyolefin"top film"is clean and dust free in order to A. Factory endlaps are provided with Polyglass proprietary FASTLap
achieve the best adhesion of the following plies. feature.These laps can be sealed in the usual way. At"BONDING
Note: For 2 or more ply systems see Step 2. AREAS"where a seam MUST be made to the granular surface,the
following alternatives are acceptable:
Alternatives at Bonding area:
Deck primed with asphalt primer 1. Granular area heated to further embed granules into SBS or APP
(where required)-or accepted compound before installing subsequent flashing piece
insulation attached to deck
2. Heat weld subsequent flashing seams with hot-air gun or mini-torch
3. Granular endlaps must be a 6" Mininum & FULLY ADHERED.This
9-12'(may vary can be achieved by carefully applying POLYPLUS 35 + SBS
Ref.Chalk kne MODIFIED TROWEL ADHESIVE in the 6" overlap area before
joining the seam surfaces
To prevent unsightly surplus adhesive on the visible area,mask the endlap
temporarily with the tape and remove when the adhesive is dry.
STEP 1
B. Ensure adhesion is achieved at all metal surfaces by priming with
D41 Asphalt Roof Primer and providing a 3"min.overlap.
Do's&Doers Details
7w4�oEso/ Installation Guide
otn rso 1rcwoorrarrwr
9.Application
A. Details are carried out by using a hot-air welding mastic
technique or Polyglass PG 500 SBS TROWEL Grade.
•
B.Heat should be applied with a flameless torch or hot-air welder
Open flame torches are not recommended.
;r t
•
'
orP I/
8.Application
A.After adhering rolls it is required that uniform pressure be
applied to the entire sheet area by using an 80 lb +'
(minimum)linoleum roller,water filled lawn roller or similar
weighted roller in a method suitable to the roof slope. R '
Care must be taken to prevent injury when rolling
membrane,especially on sloped surfaces.
�'i... 9
•
44
are
9
44111111
110401
0 Applicationf Applications 411)
� ��D7$OJ' Installation Guide
..$1.7"-AOW4'I 7ElWA' )
3.Application 5.Application
A.Fold the aligned membrane in half, exposing the dual A.At seam overlaps,align next sheet of application,fold sheet
release filmback and remove split release film. Remove, from the
B. Peel release film at a 90 degree angle in a constant motion installed roll,the protective tape,SEALLap and apply even
ensuring to keep weight on the outer edges, as you pressure to the self sealing SEALLap area,while overlapping
progress. Position the next sheet by overlapping seams the next sheet.
and line up the overlap of the top sheet edge with the inside
of the bottom sheet's factory selvage SEALLap edges.
Overlap and cut end laps minimum 6".
C. This is only one example of an application technique;
contractors may develop their own methods of application. . •
w rf' . .
rist r
PK 0.ri ._._ . .
•
•s.4 --rf-- . .
--4441
a k
6.Application
A. Roll seams and edges firmly with a steel or other suitable
-11111 A
roller to ensure full adhesion.
+
3 1 .r
itF 7
psi
4.Application 1
A.Press the membrane Into place with firm,even pressure.
Yr.,.:;
',.
Wirallir 't
i
6 . i it .
at- 7.Application
A. Applications on a slope greater than 2-12"to 12"need to be
back nailed in the seams overlap with ring shanked metal
4 capped roofing nails,6"o.c.
0 Applications Applications 0
f '
/M1410750/ .Installation Guie
�.ios�srEo ix-.suaouaor
e
APPLICATION INSTRUCTIONS 1.Application
A. Remove existing materials and obsolete penetrations
., down to an acceptable substrate, repair any voids or
'' 01
,.-
imperfections in the substrate.
+%- B. For steep-slope underlayments, cut the 2-square rolls
into a minimum of 3 equal sections.
/, . ,• i C.Unroll and allow membrane to relax in the sun for a recom-
. mended 15 minutes prior to installation in final location.
wot."/- yam''. _.,.�-y-tr r ..._ i ...
w
Nee'
Tools
1. Trowel
2. Caulking Gun • ..„ _
3. Metal Head Hand Roller
4. Tape Measure
5. Utility Knives-Hook Blade,Straight Blade
6. Claw Hammer 1
7. Tin Snips
8. Hand Held Hot Air Welder
9. Silicone Hand Held Roller
2.Applicatior,
A.Measure leading edge for width of first sheet and snap straight
-1 , ,
chalk line.
B.Lay the material flat in place,starting at the lowest point.
r� .. J C.Align the membrane with chalk line at the lowest edge of
"` the roof.
Ps Soo "_'
D.Install in shingle fashion from lowest point to highest point on roof.
dit
Accessories r_ -
1. Polyglass PG 500 TROWEL Grade Mod-Bit Adhesive-
10.3 oz cartridge
•
2.Polyglass PG 500 TROWEL Grade Mod-Bit Adhesive-
4.75 gal.Pail
3.Polyglass PG100 ASPHALT PRIMER- 14 oz spray Can
4.80 lb(minimum)linoleum roller
i
0 Tools&Accessories Applications CI
•
/ o7SOJ'e Installation Guide
��o ntism4araor
FASTLap means increased productivity
i
i. FASTLap provides a patented granule-free roll end feature.
r0. The release film is clean and simple to remove. Minimizing the ir
`‘. effort and time required to achieve a perfect end seam.
al
I
1ff.selvage release film 1 ,,
2.Surfacing(granules/sand
•EASYBOX is precut on one side of the box. 3.Factory applied adneewe treatment
•Easy removal of roll from side of the box-no more strain
from lifting the roll out of the box.
SEALLap quick waterproofing of side laps
• This is a unique patent-pending,factory-applied treatment on
the side lap of rolls to enhance sealability.
• Advantages:Instant and Permanent bond between adjacent
membranes, even under low temperature conditions. Cost
kirehisri j / Savings.No need for use of external caulk or mastics to ensure
lap bond. Labor Savings. Factory applied adhesive on the
el.
selvage areas translates to less time to install roofing
membrane. Environmentally friendly. No need for external
• Easy folding process-the box is already flat-no more mastics or heat,as required by competitors'membranes.
work wasted breaking down boxes.
•Easy stacking of flat boxes creates simple disposal-an end ACCEPTABLE SUBSTRATES
to scattered boxes littering your jobsite. Acceptable substrates for ADESO self-adhered applications:
FASTLap Enhanced End Laps -Polyisocyanurate
The sealing of the end lap between two rolls of granular -GP Densdeck Prime(pre-primed board must still be primed)
modified bitumen membranes has long been an arduous and DuraGuard®USG SecureRock•
troublesome operation. If granules are not heated and -Asphalt impregnated,six-sided Woodfiber Board
embedded satisfactorily, a reliable and durable seam may -Primed Concrete
not be achieved. If the granular areas are overheated, the
reinforcement may warp, be damaged or loss of modified -New Plywood Decking or Primed Existing Plywood
adhesive may occur. -Joints must be taped(When in doubt,prime)
Polyglass Elastobase®Poly/Sand-Base sheet,mechanically
f i t r attached,heat welded or set in hot asphalt
II\ Polyglass Elastoflex•SA V Base-Base sheet
///
l Notes:
){ f Polyglass recommends the use of Polyglass PG 500 mastic
j. \ and Polyglass PG 100 Asphalt Primer.
A`"a Contact Polyglass Technical Services for suitability of other
Isauapl IrAgnaP1 equal items at(866)802-8017.
0 Special Features FASTLap&SEALLap I Acceptable Substrates 0