1847 ATLANTIC BEACH DR - DENSITY TEST VN I V E R S A LUES Project No: 0910.1400187.0000 411 p ENGINEERING SCIENCES • Workorder No: 193027-1 • Report Date: 10/06/2017 111640 Consultants In:Geotechnical Engineering•Environmental Sciences Geophysical Services•Materials Testing•Threshold Inspection Building Code Administration,Compliance Inspection&Plan Review 5561 Florida Mining Blvd So.,Jacksonville,FL 32257 -P:904-296-0757 -F: 904-296-0748 In-Place Density Test Report Client: Toll Brothers, Inc UES Technician: Michael Zimmerman 160 Cape May Avenue Date Tested: 10/05/2017 onte v -•ra, FL 32081 Project: 18, antic Beach Dr, Atlantic Beach Country Club 'tlantic Beach Country Club,Atlantic Beach, Duval County, FL 32233 Type of Test: Area Tested: lot 49 Field: ASTM D-6938 Nuclear Gauge M ethod Material: Fill Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 = Top of Fill The tests below meet the 95%minimum compaction requirement. Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 1 4' N X 4' E FROM SWC 0- 1 ft 102.3 14.6 100.5 14.7 98 Pass 2 4' S X 4' E FROM NWC 0-1 ft 102.3 14.6 98.7 12.4 96 Pass 3 4' S X 4'W FROM NEC 0- 1 ft 102.3 14.6 97.9 11.4 96 Pass 4 4' N X 4'W FROM SEC 0- 1 ft 102.3 14.6 100.2 13.7 98 Pass SCarN cef r Y1Li To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1