1847 ATLANTIC BEACH DR - DENSITY TEST VN I V E R S A LUES Project No: 0910.1400187.0000
411 p ENGINEERING SCIENCES
• Workorder No: 193027-1 •
Report Date: 10/06/2017
111640 Consultants In:Geotechnical Engineering•Environmental Sciences
Geophysical Services•Materials Testing•Threshold Inspection
Building Code Administration,Compliance Inspection&Plan Review
5561 Florida Mining Blvd So.,Jacksonville,FL 32257 -P:904-296-0757 -F: 904-296-0748
In-Place Density Test Report
Client: Toll Brothers, Inc UES Technician: Michael Zimmerman
160 Cape May Avenue Date Tested: 10/05/2017
onte v -•ra, FL 32081
Project: 18, antic Beach Dr, Atlantic Beach Country Club
'tlantic Beach Country Club,Atlantic Beach, Duval County, FL 32233
Type of Test:
Area Tested: lot 49 Field: ASTM D-6938 Nuclear Gauge M ethod
Material: Fill Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0 = Top of Fill
The tests below meet the 95%minimum compaction requirement.
Maximum Optimum Field Dry Field Soil Pass
Test Density Moisture Density Moisture Compaction or
No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail
1 4' N X 4' E FROM SWC 0- 1 ft 102.3 14.6 100.5 14.7 98 Pass
2 4' S X 4' E FROM NWC 0-1 ft 102.3 14.6 98.7 12.4 96 Pass
3 4' S X 4'W FROM NEC 0- 1 ft 102.3 14.6 97.9 11.4 96 Pass
4 4' N X 4'W FROM SEC 0- 1 ft 102.3 14.6 100.2 13.7 98 Pass
SCarN cef r Y1Li
To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and
authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1