1835 ATLANTIC BEACH DR - DENSITY TEST Please scot
UNIVERSAL UES Project No: 0910.1400187.0000
4 p Workorder No: 195374-1
ENGINEERING SCIENCES Report Date: 12/13/2017
Consultants In:Geotechnical Engineering•Environmental Sciences
Geophysical Services•Materials Testing•Threshold Inspection
Building Code Administration,Compliance Inspection&Plan Review
5561 Florida Mining Blvd So.,Jacksonville, FL 32257 -P: 904-296-0757 -F: 904-296-0748
In-Place Density Test Report
Client: Toll Brothers, Inc UES Technician: David Caseja
160 Cape May Avenue Date Tested: 12/11/2017
Ponte Vedra, FL 32081
Project: Atlantic Beach Country Club
Atlantic Beach Country Club , Atlantic Beach, Duval County, FL
Type of Test:
Area Tested: ousepad Lot#47 in S" Field: ASTM D-6938 Nuclear Gauge Method
Material: Fil (p« 4(, 1c4 Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0 = Top of Fill (Jr. v--4
The tests below meet the 95%minimum compaction requirement.
Maximum Optimum Field Dry Field Soil Pass
Test Density Moisture Density Moisture Compaction or
No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail
1 lot 47 NW corner 0-1 ft 103.3 14.3 99.2 8.8 96 Pass
2 lot 47 NE corner 0-1 ft 103.3 14.3 100.0 8.2 97 Pass
3 lot 47 SE corner 0-1 ft 103.3 14.3 100.7 8.2 97 Pass
4 lot 47 SW corner 0-1 ft 103.3 14.3 101.4 8.0 i 98 Pass
To establish a mutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential property of our clients and
authorization for publication of statements,conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1