Loading...
Inspection 12_15_08PORT ST LUCIE, FL 34986 772-878-3350 • FAX: 772-878-5967 11326 DISTRIBUTION AVENUE WEST JACKSONVILLE, FLORIDA 32256-2745 904-268-3030 -FAX: 904-268-0724 4370 MOTORSPORT DRIVE CONCORD, NORTH CAROLINA 28027 704-782-3032 -FAX: 704-795-6838 Wi~YNE Autamt~tlic Fire Sprinklers, Inc. 222 CAPITOL CT. OCOEE, FL 34761-3033 407-656-3030 - 407-656-8026 TAMPA, FL 336109 81 3-630-0303 • FAX: 81 3 -630-0312 4683 LAREDO AVENUE FORT MYERS, FLORIDA 33905 239-433-3030 -FAX: 239-433-3263 3121 NW 16TH TERRACE POMPANO BEACH, FLORIDA 33064 954-917-3030 -FAX: 954-917-9424 NFPA-25 Inspection, Testing and Maintenance of Dry-Pipe Fire Sprinkler Systems Information on this form covers the minimum requirements of NFPA 25-2002 for fire sprinkler systems connected to distribution systems without supplemental tanks or fire pumps. Separate forms are available to inspect, test, and maintain fire pumps, water tanks and other fire protection systems. More frequent inspection, testing and maintenance may be necessary depending on the conditions of the occupancy and the water supply. Owner: BBT Investors LLC Owner's Address: 2251 St. Johns Bluff Road S. Jacksonville, FL. 33246 Property Being Evaluated: Dresser Rand Property Address: 482 - 4828 Stewart St. Atlantic Beach, FL. 32232 Date of Work: ~ 5 December 2008 This work is (check one): Part I -Owner's Section All responses refer to the current work (inspection, testing and maintenance) performed on this date. QWlonthly Q Quarterly 0 Annual oThird Year O Fifth Year A. Is the building occupied? B. Has the occupancy classification and hazard of contents remained the same since the last inspection? C. Are all fire protection systems in service? D. Has the system remained in service without modification since the last inspection? E. Was the system free of actuation of devices or alarms since the last inspection? F. Weekly logs of inspections required by NFPA-25 on file? G. All deficencies reported at last inspection corrected? H. I know the location and understand the operation of all cor}(r~ valves. Owner or representative (print name) Signature and Date Part II -Inspector's Section A. Inspections t. Daily and Weekly Items A. Control valves supervised with seals in coned (open or closed) position? B. Dry-Pipe valves: Enclosures around valves maintaining a minimum of 40 F and gauges in good condition showing normal air and water pressure? C. Back Flow Preventers 1. Valves in correct (open or closed) position? 2. Sealed, locked or supervised 8 accessible? 3. Relief port on RPZ device not discharging? D. For freezer systems, is the gauge near [he compressor reading the same as the gauge near the dry-pipe valve? 2. Monthly Inspection Items (in addltlon to above items) A. Control valves with locks or electrical supervision in correct open or closed) position? B. Dry-Pipe Valves: Free from physical damage, trim valves in appropriate (open or closed) position, and no leakage from intermediate chamber? C. Sprinkler wrench with spare sprinklers? 3. Quartlery Inspection Items (in addition to above items) A. Pressure Reducing Valve: In open position, not leaking, maintaining downstream pressure per design criteria, and in good condition with handwheels not broken? B. Hydraulic nameplate (calculated systems) securely attached [o riser and legible? G. Fire Department Connections: Visible, accessible, couplings and swivels not damaged and rotate smoothly, plugs or caps in place and undamaged, gaskets in place and in good condition, identification sign(s) in place, check valve is not leaking, clapper is in place and Yes QNo s QNov~Yes QNo es QNo V ' es Q O Yes es o Yes QNo 15 December 2008 B. Testing operating properly and automatic drain valve in place and operating properly?O Yes QNo QN/A If plugs or caps are not in place, inspect interior for obstructions.) 4. Annual Inspection Items (in addition to above items) A. Proper number and type of spare sprinklers?O. Yes QNo ON/A B. Visible spinklers: 1. Free of corrosion and physical damage?O Yes QNo ON/A 2. Free of obstructions to spray patterns?O Yes QNo ON/A 3. Free of foreign materials including paint?O Yes QNo ON/A 4. Liquid in all glass bulb sprinklers?Q Yes QNo QN/A C. Visible pipe: Date ISC#: )00776 Report#: Owner's Phone Number: 904.645.0003 1. In good condition/no external corrosion? 2. No mechanical damage and no leaks? 3. Properly aligned and no external loads? D. Visible pipe hangers and seismic braces not E. Dry-pipe valves passed internal inspection? F. Must be done before cold weather 1. Adequate heat in areas with wet piping? 2. Low temperature alarms functioning? O Yes QNo QN/A O Yes QNo QN/A O Yes QNo O. N/A damaged or loose? O Yes QNo QN/A O Yes QNo Qi N/A O Yes QNo ON/A O Yes QNo QN/A O Yes QNo QN/A 3. Interior of pipe that passes through freezers free of ice blockage? ONIC QYes QNo Qi N/q G. Has an intemal inspection of the pipe been performed by Oi Yes QNo ON/A removing the flushing connection and one sprinkler near the end of a branch line within the last 5 years? ONIC QYes QNo Oehl/A Qi Yes QNo QN/A if the answer was "No", conduct an internal inspection.) Oi Yes QNo ON/A 5. Fifth Year Inspection Items (in addition to above items) O Yes QNo ON/A A. Check valves internally inspected and all parts operate properly, move freely and are in good condition? O NIC O Yes QNo Oi N/A O Yes QNo Oi N/A B. Strainers, filters, restricted orifices and diaphragm chambers on dry-pipe valves passed internal inspection? QNIC QYes QNo Qi N/A B. Testing O Yes QNo QN/A The following tests are to be performed at the noted intervals. Report any failures on Part III of this form. 1. Quarterly Tests Qi Yes QNo ON/A A. Mechanical water flow alarm devices passed tests by opening Qi Yes QNo ON/A the inspector's test connection or bypass connection with alarms O Yes O No actuating and Flow observed? O Yes O• No QN/A QNot installed. B. Post indicating valves opened until spring or torsion is felt in the QDesign criteria is not available rod, then closed back one-quarter turn? O Yes QNo ON/A C. Is the priming level correct? Oi Yes QNo V"/A D. Has low air signal passed its test? O Yes QNo Oi N/A O Yes O• No E. Quick opening devices passed test? QProvisions not provided.QYes QNo ON/q F. Main drain test for system downstream of backflow or pressure reducing valve: 1. Record Static Pressure 50 psi and Residual Pressure 40 psi. 2. Was Flow observed? Qi Yes QNo QN/A 3. Are results comparable to previous test? Q Yes ~ No ON/A