Loading...
180 SANDY BEACH LN - PERMIT ' �m CITY OF ATLANTIC BEACH ss1 r 0 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 -fin 9' INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0239 Description: new attached single-family home Estimated Value: 141425.8 Issue Date: 11/28/2017 Expiration Date: 5/27/2018 PROPERTY ADDRESS: Address: 180 SANDY BEACH LN RE Number: 173414 0160 PROPERTY OWNER: Name: BEACHES HABITAT FOR HUMANITY INC Address: 797 MAYPORT RD ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Address: 2768 STATE RD A1A#701 ATLANTIC BEACH, FL 32233 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. i rs �v.r,;,, City of Atlantic Beach APPLICATION NUMBER • Building Department (To be assigned by the Building Department.) r ?. \''.2) 800 Seminole Road �. -- - Atlantic BeachFlorida 32233-5445 n-ES r� _ O a Phone(904)24,7-5826 • Fax(904)247-5845 `" 010- E-mail: building-dept@coab.us Date routed: [ti - J1'4 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1%0 S 04\13m Lf\ • De Jartment review required Ye - No (uTding J Applicant: a 0 k Ma-kk Poi k 0-6(1SKuLPlannin & g Zoning Tree mi Project: (\k-4,D ctA-U.k\1.a 5'0\,44, CIALks.tiF_Lkiblic-Vtlik's-- Public Utilities] Public Safety Fire Services Review fee $ _ Dept Signature Review or Receipt Other Agency Review or Permit Required Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department j First Review: Voved. ❑Denied. Not applicable (Circle one.) Comments: UILDING \) PLANNING & ZONING Reviewed by: (1 Date: `l' 7-2017 TREE ADMIN. Second Review: I 'Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 BUILDING PERMIT APPLICATION OFFICE COPY CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904)247-5826 Fax (904) 247-5845 Job Address: # 180 Sandy Beach Lane, COAB, 32233 Permit Number: _ R-� (30-1c) Legal Description: 38-2S29E-7.41B De Castro Y Ferrr Grant PT RECD O/R 16531-2248 Parcel#Blk: 1 Lot: 1 Floor Area of Sq.Ft. S .Ft Valuation of Work$110.000 Proposed Work heated/cooled 1172 non-heated/cooled 188 Class of Work(circle one): New (X) Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No(X) N/A Florida Product Approval# For multiple products use product appi'WaTform Describe in detail the type of work to be performed: Construct attached two story Triplex single family homes Property Owner Information: Name: Beaches Habitat for Humanity Address: 797 Mayport Rd City Atlantic Beach State FL Zip 32233 Phone#904-241-1202 E-Mail or Fax#(Optional)#904-241-4310,rpeterson@beacheshabitat.org Contractor Information: Company Name:201 Mayport Construction Management, LLC Qualifying Agent: Robert Peterson Address: 2768 State Rd.AlA#701 City Atlantic Beach State FL Zip 32233 Office Phone 904-595-5798 Job Site/Contact Number_904-334-1202 Fax# State Certification/Registration#.CGC 1506666 Architect Name&Phone# AA1 arvv.. C).Eby qeM - 109- Engineer's Name&Phone# M:t>-'O.i \ F\-.o\dw '\O'4- (Q(h O - t.e 219 Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void if work is not commenced within six(6)months,or if construction or work is suspended or abandonedfor aperiod of six6)months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells,Pools,Furnaces,Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined thisplication and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be corn. 'ed with whether speaffed herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other fede . state,or local law regulating construction or the performance of construction. Signature of Owner 1 i Signature of Contractor Print Name �, 'red(9(ir Print Name •R -o„.4-- F,A= rscM Sworn to and sub bed beforq me '20 17 Sworn to and subscribed before,,{{mme this 2t Day of Uthis 76"—Day of t , 20/ . NOta ,,,,,,,,,,, lotary Pu r• MURRAY �,,,un,,., LE MURRAY ,s.OA °�e sa P, `�; Notary Public State of Florida �� r 1 t Notary Public•State of Florida I _ 1 Revised 01.26.10 •E Commission#FF 941841 N �r Commission•FF 941841 1 �� %�, --40 P My Comm.Expires Apr 2,2020 My Comm.Expires Apr 2,2020 •-. a,,d;.• ���,�,,,,� Bonded through National Notary Assn. Bonded throuah National Notary Assn. 1 OFFICE COPY • DO NOT WRITE BELOW- OFFICE USE ONLY ApplicaI e Coes: 2OJOFLORIDA BUILDING CODE Review Result circle one : ApprOVed Disapproved A pproved w/ Conditions Review Initials/Date: j_17+ t 7 beyelopm-en-t Size Habitable Space /1 X2 S-rNon-Habitable / 86, S, / • -npervious area • discellaneous Information ccupancy Group 12-3 ype of Construction V 6 amber of Stories D. Hing District 12 G- Lx. Occupancy Load Sprinklers Required • • )d Zone X ditions/Comments: • , PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA OFFICE COPY Project Name: OceanGate: Tri-plex"A" Permit# RES / 7 Oa 3 Project Address: #172, 176, 111e0 Sandy Beach Lane, COAB, 32233 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.or.. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # A. EXTERIOR DOORS 1. Swinging Masonite Steel Door FL4904 2. Sliding 3. Sectional 4. Roll up Clopay Garage Door- HDG FL5684.10 5. Automatic 6. Other B.WINDOWS 1. Single hung Atrium Single Hung Window FL11834.10 2. Horizontal slider 3. Casement _ 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11.. Dual action 12.. Other , PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA C. PANEL WALL 1. Siding James Hardie Cemplank siding FL13192.1 2. Soffits Crane Vinyl Soffit FL2495-R1 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco Acrocrete Synthetic finish coat _ 11. Other _ D. ROOFING PRODUCTS 1. Asphalt shingles GAF 30 yr architectural FL10124 2. Underlayments RhinoRoof Syn. Underlayment FL15216 3. Roofing fasteners 4.Nonstructural metal roof Millenia Metals Form rolled metal FL5211.2 R4 5. Built-up roofing 6. Modified bitumen Certainteed Flintlastic SA FL2533 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coasts 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other E. SHUTTERS 1. Accordion Shutter Shield Accordion FL9569.1 2. Bahama 3. Storm panels Madden Mfg. Storm Panels FL5329.1 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor Simpson Strong- H 16 FL1423.6 Tie MTS 12 FL474.253 2. Truss plates MiTek Industries Truss Plates FL2197 3. Engineered lumber Tus-Joist- Engineered Lumber FL 1630 Weyerhauser 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturer,product description and State approval number for the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected,they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Authorized Project Agent: Robert Peterson; Director of Construction (Contractor or Design Professional) (Print Name) ( : : •. - Company Name: Beaches Habitat for Humanity Mailing Address: 797 Mayport Road PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA City: Atlantic Beach State: FL Zip Code: 32233 Telephone Number: ( 904) 241-1222 Fax Number: (904 ) 241-4310 Cell Phone Number: ( 904) 334-1202 E-mail Address: rpeterson@a,beacheshabitat.org OFFICE COPY l� Sim/14 bead" FORM R405-201A RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include This checklist A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). -ND Energy Performance Level(EPL) Display Card(one page) Mandatory Requirements(three pages) Required prior to CO for the Performance Method: Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) �6l A completed Envelope Leakage Test Report(usually one page) �F7 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 8/24/2017 11:42:57 AM EnergyGauge®-USRCSB v5.1 Page 1 of 1 I I OfFICECOPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-TRIPLEXOUTSIDE180SB Builder Name: BEACHES HABITAT Street 180 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State,Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location. FL,Jacksonville County:: DUVAL(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Frame Wood,Exterior R=19.0 1138.70 ft' b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5 Is this a worst case? No 10.Ceiling Types (572.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 572.00 ft2 6. Conditioned floor area above grade(ft2) 1140 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 C.N/A R= ft2 11.Ducts R ft2 7. Windows(130.0 sqft.) Description Area a.Sup: 1st Floor,Ret:1st Floor,AH: 1st Floor 6 165 a. U-Factor Dbl,U=0.30 130.00 ft2 SHGC: SHGC=0.30 b. U-Factor. N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 23.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (568.0 sqft.) Insulation Area EF:0.920 a Slab-On-Grade Edge Insulation R=0.0 568.00 ft2 b. Conservation features b N/A R= ft2 None c NIA R= ft2 15 Credits Pstat Total Proposed Modified Loads: 28.69 PASS Glass/Floor Area: 0.114 Total Baseline Loads: 32.85 I hereby certify that the plans and specifications covered by Review of the plans and :.O�TNE StgT�••• this calculation are in compliance with the Florida Energy specifications covered by thisv - - Oma,?, 1.4.77././.-•::, Code. calculation indicates compliance ;h, „ ,,.`' ,��.1 • with the Florida Energy Code. - •i „ ^zrisc'.__70-it. • k '� : DATE: _- 81 41-7 this buildingwill be inspected for p4' C P 0 _ _c.- -- Florida ,a compliance with Section 553.908two Statutes. I hereby certify th this building,as designed,is in compliance ;.� w, with the Florida Ener d '•:Cob yy,ETsJ • OWNER/AGENT: _ _ tt-__ BUILDING OFFICIAL: /' ' 11 7-.9-on DATE: _._ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 this project requires an envelope leakage test report with envelope leakage no greater than 3.0 ACH50(R402.4.1.2). 8/24/2017 11:43 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4 I FORM R405-2014 PROJECT Title: HABITAT-TRIPLEXOUTSIDE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1140 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook. Builder Name: BEACHES HABITAT Rotate Angle: 0 Street: 180 SANDY BEACH LA Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block/ 1140 9120 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 568 4544 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 572 4576 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 0 568 ft2 ____ 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) V 1 Gable or shed Composition shingles 603 ft2 96 ft2 Medium 0.85 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC -- ------------- --------- 1 Full attic Vented 300 572 ft2 N N CEILING V #__ Ceiling Type __ Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 Batt 572 ft2 0 Wood 8/24/2017 11:43 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 2 of 4 I I / FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below �a S Qrnt Tp Wall Type Space R-Value El In Ft In Area R-Value Frarijnn Ahcor Grade° _ 1 SE Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 ' 2 SW Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 N, 3 NW Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft2 0.23 0.75 0 4 NE Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 �t 5 SE Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 V 6 SW Exterior Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 \� 7 NW Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft2 0.23 0.75 0 �+ 8 NE Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS • # Omt Door Type Space Storms • U-Value Width Height Area Ft In Ft In 1 SE Insulated 1st Floor . Metal .46 3 6 8 20 ft2 2 S Insulated 1st Floor Metal .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 SE 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 2 SE 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None NJ 3 SW 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 SW 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 SE 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None Ni 6 SE 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None \2 7 SW 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 SW 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 NW 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 NW 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000152 456 25.03 47.08 .1446 3 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity _ _ Block Ducts 1 Electric Heat Pump None HSPF:8.5 23.5 kBtu/hr 1 sys#1 8/24/2017 11.43 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 3 of 4 .... I • FORM R405-2014 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts ~ 1 Central Unit Split SEER: 15 24 kBtu/hr 720 cfm 0.75 1 sys#1 HOT WATER SYSTEM _ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area. Volume FEF None None DUCTS Supply---- —Return-- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage 1st Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin X Jan X Feb X Mar X A r X Ma X Jun X Jul X A Sep X Oct X Nov X Dec Heatinf Xi Jan [Xi Feb f Xi Mar f Xi Apr [Xi Ma [Xi Jun [Xi Jul vii til [Xi Sep 'Xi Oct �Xi Nov XJ Dec Venting (X Jan [X Feb [X Mar [X r [X MayX Jun [X Jul [X Augu [X Sep 'X Oct X Nov X]Dec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 8/24/2017 11:43 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4 l I J FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. 180 SANDY BEACH LANE, ATLANTIC BEACH , FL, 32233 1 New construction or existing New(From Plans) 9 Wall Types Insulation Area 2 Single family or multiple family Multi-family a. Frame-Wood,Exterior R=19.0 1138.70 W b Frame-Wood.Common R=19.0 498 67 ft' 3 Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d N/A R= ft' 5 Is this a worst case? No 10 Ceiling Types Insulation Area a. Under Attic(Vented) R=30.0 572.00 ft' 6 Conditioned floor area(W) 1140 b.N/A R= ft' c. N/A R= ft' 7 Windows" Description Area 11 Ducts R ft' a. U-Factor: Dbl,U=0.30 130.00 W a.Sup: 1st Floor Ret 1st Floor,AH 1st Floor 6 165 SHGC. SHGC=0.30 b U-Factor: N/A ft' SHGC. 12 Cooling systems kBtu/hr Efficiency c U-Factor N/A ft' a Central Unit 24.0 SEER:15.00 SHGC d U-Factor N/A ft' SHGC 13.Heating systems kBtu/hr Efficiency a Electric Heat Pump 23.5 HSPF:8 50 Area Weighted Average Overhang Depth 3.252 ft Area Weighted Average SHGC. 0.300 8. Floor Types Insulation Area 14. Hot water systems a Electric Cap-40 gallons a Slab-On-Grade Edge Insulation R=0.0 568.00 ft EF 0 92 b N/A R= ft' c N/A R. ft' b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building •'"111EST " Construction through the above energy saving features which will be installed (or exceeded) :'' °I..-_.-- -•.?FOS,. in this home before final inspection. Otherwise, a new EPL Display Card will be completed =� =,,. based on installed Code compliant features. i t-:4, •;. `4..,,o ai-.. C: o : i Builder Signature: 1T Date: ` —�j /r 7 c�.,__ �, :a Address of New Home / (� L et") {�!"G�C City/FL(Zip: (Co 4- � *• p • -. COU w-E. -3�3Z a 'Note. This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/24/2017 11:43 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 ! i FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS 180 SANDY BEACH LANE Permit Number ATLANTIC BEACH ,FL 32233 MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy Florida law (Section 553 9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402 1 through R402 4 4 O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402 4 1 1 and R402.4 1.2 The sealing methods between dissimilar materials shall allow for differential expansion and contraction • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402 4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1 1,as applicable to the method of construction Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g (50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g).or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope During testing 1 Extenor windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake.makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3 Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5 Heating and cooling systems,if installed at the time of the test,shall be turned off,and 6 Supply and return registers,if installed at the time of the test,shall be fully open O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1 5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMANVDMA/CSA 101/I S 2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer Exception: Site-built windows. skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2 0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that.except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2 7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489 105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free'by either of the following- 1 Post-construction test Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9 29 m2)of conditioned floor area when tested at a pressure differential of 0 1 inches w.g (25 Pa)across the entire system.including the manufacturers air handler enclosure All register boots shall be taped or otherwise sealed during the test 2 Rough-in test Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9 29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system, including the manufacturer's air handler enclosure All registers shall be taped or otherwise sealed during the test If the air handler is not installed at the time of the test total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9 29 m2)of conditioned floor area Exceptions- 1 The total leakage test is not required for ducts and air handlers located entirely within the building envelope 2 Duct testing is not mandatory for buildings complying by Section R405 of this code 8/24/2017 11T43 AM EnergyGauge®USA-v5 1 - Section R405.4.1 Compliant Software Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105`F(41°C) or below 55`F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Y inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404 2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water heating systems should meet the following criteria, 1 Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal,and 2 Be installed at an orientation within 45 degrees of true south R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies. based on building loads for the directional orientation of the building The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1 This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load.but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load 8/24/2017 11,43 AM EnergyGaugee USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3 'WNW' FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment This selection shall be used to select cooling-only equipment This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space Exceptions. 1 Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2 When signed and sealed by a Florida-registered engineer. in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice O R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403 6 1 1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1 ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403 6 1 O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis.such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options. 1 A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas 2 A variable capacity system sized for optimum performance during base load periods is utilized R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403 R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9 3 and in accordance with ANSI/APSP-15 The energy requirements for portable spas shall be in accordance with ANSI/APSP-14 O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum • thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21 56 Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4 0 when tested in accordance with AHRI 1160.Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment Exceptions: ' 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems 3 Where pumps are powered exclusively from on-site renewable generation O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or • solar energy source computed over an operating season RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6 O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19 Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space.R-10 is allowed 8/24/2017 11 43 AM EnergyGauger1i USA-v5 1 - -Section R405 4.1 Compliant Software Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name. HABITAT-TRIPLEXOUTSIDE180SB Builder Name: BEACHES HABITAT Street 180 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State,Zip ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. �V Rim joists Rim joists are insulated and include an air barrier. y Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawispace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I \\i vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. V Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available \ , space shall extend behind piping and wiring. �1 Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls Fireplaces shall have gasketed doors 8/24/2017 11:43 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 I I • I I Manual S Compliance Report Job: 180 SB Lane -f wrightsoft p p Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140E 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone 904-823-9696 Web:\MMN.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 17608 Btuh Entering coil DB: 76.9°F Outdoor design WB: 77.0°F Latent gain: 3181 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 20789 Btuh Indoor RH: 50% Estimated airflow: 700 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Sensible capacity: 18041 Btuh 102%of load Latent capacity: 4022 Btuh 126%of load Total capacity: 22063 Btuh 106%of load SHR: 82% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 19908 Btuh Entering coil DB: 68.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Output capacity: 18689 Btuh 94%of load Capacity balance: 29 °F Supplemental heat required: 1219 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 700 cfm Output capacity: 4.7 kW 81%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 2017-Oct-17 20:12:11 wrightsoft Right-Suite®universal 2017 17.0.29 RSU09479 Page 1 ...\Beaches Habitat\180 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE Project SummaryJob: 180 SB Lane 41- ro wrightsoft Date: 1047-2017 Entire House By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Pro-ect Information For: Beaches Habitat Notes: 180 Sandy Beach Lane Desi• n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16590 Btuh Structure 14673 Btuh Ducts 3318 Btuh Ducts 2935 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19908 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17608 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2100 Btuh Ducts 1081 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1140 1140 Equipment latent load 3181 Btuh Volume(ft3) 9920 9920 Air changes/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 20789 Btuh Equiv.AVF(cfm) 74 38 Req.total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A00300 Cond 25HBC524A00300 AHRI ref 9154698 Coil FX4DNF025L AHRI ref 9154698 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 16800 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 7200 Btuh Temperature rise 31 °F Total cooling 24000 Btuh Actual air flow 700 cfm Actual air flow 700 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.85 Ca pacity balance point=29°F Backup: Input=5 kW, Output= 16145 Btuh, 100 AFUE Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2017-Oct-17 20:12:11 g Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 ...\Beaches Habitat\180 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE + wrightsoft Right-J® Worksheet Job: 180 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:VW'AN NORTHFLORIDAAIR.COM 1 Room name Entire House Kitchen 2 Exposed wall 204.0 ft 25.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 14.0 x 11.0 ft 5 Room area 1240.0 ft' 154.0 ft' r I r r Ty Construction U-value Or 1 HTMI Area (ft') Load Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I WP/S Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 496 496 1265 712 88 88 224 126 12E-Osw 0.068 se 2.55 1.43 320 239 609 343 0 0 0 0 1D-clow 0.570 se 21.38 38.87 31 4 667 1213 0 0 0 0 1D-clow 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 11 1D-clow 0.570 se 21.38 18.20 15 15 315 268 0 0 0 0 0 11D0 0.390 se 14.62 11.78 20 20 298 240 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 496 454 1159 652 0 0 0 0 -G 1D-clow 0.570 sw 21.38 36.78 6 1 128 221 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 21 3 445 809 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 15 2 315 573 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 320 248 632 356 112 92 234 131 1D-c2ow 0.570 nw 21.38 39.24 31 0 667 1224 0 0 0 0 11D0 0.390 nw 14.62 11.78 41 41 597 481 20 20 298 240 C 16B-30ad 0.032 - 1.20 1.72 144 144 173 247 28 28 34 48 C 16B-7ad 0.112 - 4.20 6.01 496 496 2083 2983 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 640 104 3857 0 154 25 927 0 6 333 I Envelope loss/gain c)AED excursion -263 13525 11009 1717 283 12 a) Infiltration 3065 744 376 91 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 2000 2000 Subtotal(lines 6 to 13) 16590 14673 2093 2374 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 394 138 14 Subtotal 16590 14673 2487 2512 15 Duct loads 20% 20% 3318 2935 20% 20% 497 502 I I Aotaequired(cdm) ( I 197900801 17700001 I 1 29851 05 30141 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. � -444- wrightsoft 2017-Oct-17 20:12:11 oic_.c„ -s Right-Suite®U niversal 2017 17.0,29 RSU09479 Page 1 ...\Beaches Habitat\180 Sandy Beach Lane\1140Lrup Calc=MJ8 Front Door faces.SE 4 wrightsoft Right-J® Worksheet Job: 180 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Utility Bath 1 2 Exposed wall 10.0 ft 9.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 4.0 ft 6.0 x 9.0 ft 5 Room area 24.0 ft' 54.0 ft' 1 I I I t I Ty Construction U-value OrHTM Area (ft') Load Area (ft') Load number (Btuh/ft'-'F I (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) I Heat I Cool Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-clow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1 D-clow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 1 1 1 D1-c2ow 0.570 00 0 O 11 DO 0.390 sese 21 14.62.38 118.201.78 00 00 00 00 00 00 0 W 12E-Osw 0.068 sw 2.55 1.43 32 32 82 46 72 66 168 95 -G 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 6 1 128 221 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 G 1D c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 48 28 70 40 0 0 0 0 1 D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 12 12 14 21 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 24 10 371 0 54 9 334 0 61 c)AED excursion I I 381 I83 Envelope loss/gain 836 308 630 398 12 a) Infiltration 150 36 135 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 986 345 766 431 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -986 -345 719 231 14 Subtotal 0 0 1485 662 15 Duct loads 20% 20% 0 0 20% 20% 297 132 Air req d(cfm) I I I OI 00I 1782 631_- 732 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w/iglitsoft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-17 2Pa2:11 e 2 ? \ ..\Beaches Habitat Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE 9 4 wrightsoft Right-J® Worksheet Job: 180 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:VWWJ.NORTHFLORIDAAIR.COM 1 Room name Great Mech 2 Exposed wall 55.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 378.0 ft 6.0 x 5.0 ft 5 Room area 378.0 ft' 30.0 ft' I I r r r t Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 1 6 W 12E-Osw 0.068 ne 2.55 1.43 168 168 428 241 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 160 110 281 158 0 0 0 0 1 D-clow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 11 1D-c2ow 0.570 se 211.38 18.20 15 15 315 268 0 0 0 0 0 1100 0.390 se 14.62 11.78 20 20 298 240 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 112 102 259 146 40 40 102 57 -0 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 10 1 222 404 0 0 0 0 G 1 D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 1178 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 378 55 2040 0 30 5 185 0 • 6 c)AED excursion t 1 -201 4159 287 -8 Envelope loss/gain 12 a) Infiltration 826 201 75 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4985 1812 363 68; Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 235 44 -363 -68 14 Subtotal 5220 1856 0 0 15 Duct loads 20% 20% 1044 371 20% 20% 0 0 Air reguied(cfm) I I 62 26401 2228 891 I I 001 010 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 434- wrightsoft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-17 20:12:11 ate 3 ,C77.--(7.-P... ...\Beaches Habitat\180 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE g +}+ wrightsoft Right-J® Worksheet Job: 180 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WVWV.NORTHFLORIDAAIR.COM 1 Room name M WIC Master 2 Exposed wall 12.0 ft 23.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 5.0 ft 13.0 x 10.0 ft 5 Room area 35.0 ft' 130.0 ft' r i I I r r Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-'F (Btuh/ft') 1 or perimeter (ft) f (Btuh) or perimeter (ft) (Bluh) f Heat I Cool I Gross I WP/S I Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 80 80 204 115 12E-Osw 0.068 se 2.55 1.43 56 56 143 80 104 73 186 104 1D-clow 0.570 se 21.38 38.87 0 0 0 0 31 4 667 1213 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 40 40 102 57 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1 D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 G 1D c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 35 35 42 60 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 130 130 546 782 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion I 287 174-241 1603 25391 Envelope loss/gain 12 a) Infiltration 180 44 346 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 467 217 1948 3083 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 160 189 280 329 14 Subtotal 627 406 2228 3412 15 Duct loads 20% 20% 125 81 20% 20% 446 682 Air req ed(cfm) 1 1 7531 26 4881 1 1 26941 406 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ' ' wrightsoft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-17 2 Pate 4 A \Beaches Habitat\180 Sandy Beach Lane\1140Lrup Calc=MJ8 Front Door faces:SE g 4 wrightsoft Right-J® Worksheet Job: 180 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M Linen Bath 2 2 Exposed wall 0 ft 9.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 3.0 x 5.0 ft 6.0 x 9.0 ft 5 Room area 15.0 ft' 54.0 ft' r I I I I I Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') 1 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) 1 Heat I Cool I Gross I N/P/S Heat I Cool 1 Gross N/P/S Heat 1 Cool I 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 72 72 184 103 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-clow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 11 1 D-clow 0. 0 0 0 0 0 0 0 0 11 DO 0.390570 sese 2141,6328 11.7818.20 0 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 0 0 0 0 -G 1D-clow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 15 15 18 26 54 54 65 93 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 r 6 c)AED excursion I18 23-3I 2481 -23 173 Envelope loss/gain 12 a) Infiltration 0 0 135 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 18 23 384 206 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -18 -23 345 405 14 Subtotal 0 0 729 611 15 Duct loads 20% 20% 0 0I 20% 20% 146 122 Air regUomdl(adn) I I 00 0( I I 83151 7291 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Oct-17 20:12:11 wrigl�tsoft Right-Suite®U niversal 2017 17.0.29 RSU09479itn�'P Page 5 _.\Beaches Habitat\180 Sandy Beach Lane Calc=MJ8 Front Door faces:SE g 4 wrightsoft Right-J® Worksheet Job: 180 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140L 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:NMW.NORTHFLORIDAAIR.COM • 1 Room name Bed 3 Bed 2 2 Exposed wall 21.0 ft 21.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 11.0 ft 10.0 x 11.0 ft 5 Room area 110.0 ft' 110.0 ft' I I I I r r Ty Construction U-value Or 1 HTMI Area (f t') Load I Area (ft') Load number (Btuh/ft'-'F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool 1 Gross 1 N/P/S Heat I Cool 1 Gross I N/P/S Heat Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 88 88 224 126 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 88 73 187 105 -G 1 D-c2ow 0.570 sw 21.38 36.78 0 0 0 0 0 0 0 0 -G 1 D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 15 2 315 573 b12E-Osw 0.068 nw 2.55 1.43 80 64 164 92 80 64 164 92 1 D-c2ow 0.570 nw 21.38 39.24 16 0 333 612 16 0 333 612 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 110 110 462 662 110 110 462 662 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 I 61 c)AED excursion I I I 37 I2991 Envelope loss/gain 1 If I{ 1184 1629 I{ 1461 2343 12 a) Infiltration 316 77 316 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 1500 1936 1777 2649 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 154 180 384 450 14 Subtotal 1653 2116 2161 3099 15 Duct loads 20% 20% 331 423 20% 20% 432 620 AAir required(cfm) 19 70 210 I I f 25 93 91 I 37181 148 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -- vv-4-14- f ightsoft Right-Suite®U niversal 2017 17.0.29 RSU09479 2017-Oct-17 20:12:11 ate 6 � ""�" ...\Beaches Habitat\180 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE g 4 wrightsoft Right-J® Worksheet Job: 180 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 114OL 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:VVVWV.NORTHFLORIDAAIR.COM 1 Room name Loft 2 Exposed wall 140 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 1.0 x 146.0 ft 5 Room area 146.0 ft' i 1 I I I r Ty Construction U-value Or HTMI Area (ft') Load Area Load number (Btuh/ft'-'F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter 1 Heat I Cool I Gross I WP/S Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 1D-clow 0.570 se 21.38 38.87 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 1 1 1 D1-clow 0.5701181.27080 0 0 0 D 1 1 DO 0.390 sese 21 14.62.38 0 0 0 0 VJ 12E-Osw 0.068 sw 2.55 1.43 112 102 259 146 -G 1D-clow 0.570 sw 21.38 36.78 0 0 0 0 -G 1D-c2ow 0.570 sw 21.38 38.87 10 1 222 404 -G 1D-c2ow 0.570 sw 21.38 38.87 0 0 0 0 H12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 1 D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 1 1 DO 0.390 nw 14.62 11.78 0 0 0 0 C 168-30ad 0.032 - 1.20 1.72 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 146 146 613 878 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 c)AED excursion 49 6 I Envelope loss/gain 1 109511477 I 12 a) Infiltration 210 51 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1305 1529 Less external load 0 0 Less transfer 0 0 Redistribution -1305 -1529 14 Subtotal 0 0 15 Duct loads 20% 20% 0 0 A Totalrrequireroomd load(cfm) I I I 001 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2017-Oct-17 20:12:11 Right-Suite%Universal 2017 17.0.29 RSU09479 Page 7 ?"'A ...\Beaches Habitat\180 Sandy Beach Lane)1140L.rup Calc=MJ8 Front Door faces:SE Floor Utility 11. Kitchen Bath 1 '' cfm ►.: 120 cfm 6 " 10 " 6 " r.;!► 700 cfm • Mech 11 ) cfm Sup Riser 0 2 6 " Great • 11 ) cfm Job#: 180 SB Lane Scale 1 : 48 Performed for: Florida Air Service & Engineering Page 1 Beaches Hatrca! 150 Hilden Road 308 Right-Suite®Uni eersal 2017 Ponte Vedra Fl 32081 17.0 29 RSU09479 Phone 904-823-9696 2017-Oct-17 20 12 33 VWWV NORTHFLORIDAAIR COM t\180 Sandy Beach Lane\1140L 2nd Floor - Bed 2 Bed 3 148 cfm 12x10 12x10 101 cfm P7 6 " 6 " Sup Rise 12 " ,, Bath 2 Loft 31 cfm 12 x 10 4 " Liner e 4 " 10.481 cfm Master 26 cfm 81 cfn M WIC © o Job#: 180 SB Lane Scale: 1 :48 Performed for: Florida Air Service & Engineering Page 2 Beaches Habitat 150 Hilden Road 308 Right-Suite®Unkersal 2017 Ponte Vedra, Fl 32081 17.0.29 RSU09479 Phone 904-823-9696 2017-Oct-17 20:12:33 VWWV.NORTHFLORIDAAIR.COM t\180 Sandy Beach Lane\1140L... Duct System Summary Job: 180 SB Lane wrightsoft4 Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140E 150 Hilden Road 308.Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WVWJ.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply/return available pressure 0.125/0.125 in H2O 0.125/0.125 in H2O Lowest friction rate 0.100 in/100ft 0.100 in/100ft Actual air flow 700 cfm 700 cfm Total effective length(TEL) 132 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 1 h 1782 63 32 0.100 4.0 Ox 0 VIFx 15.2 100.0 st4 Bath 2 h 875 31 29 0.100 4.0 Ox 0 VIFx 0 0 Bed 2 c 3718 91 148 0.100 6.0 Ox 0 VIFx 19.6 110.0 st1 Bed 3 c 2539 70 101 0.100 6.0 Ox 0 VIFx 16.2 110.0 st1 Great h 3132 110 44 0.100 6.0 Ox 0 VIFx 15.6 100.0 st4 Great-A h 3132 110 44 0.100 6.0 Ox 0 VIFx 24.6 100.0 st4 Kitchen c 3014 105 120 0.100 6.0 Ox 0 VIFx 11.6 100.0 st4 M WIC h 753 26 19 0.100 4.0 Ox 0 VIFx 22.4 110.0 st1 Master c 2047 47 81 0.100 4.0 Ox 0 VIFx 14.9 110.0 st1 Master-A c 2047 47 81 0.100 4.0 Ox 0 VIFx 0 0 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 234 350 0.100 445 12.0 0 x 0 VinIFIx st4 Peak AVF 388 240 0.100 711 10.0 0 x 0 VinlFlx st2 st2 Peak AVF 388 240 0.100 711 10.0 0 x 0 VinlFlx Bold/italic values have been manually overridden wrht50ft' 2017-Oct-1720:12:12 9 ARight-Suite®Universal 2017 17.0.29 RSU09479 Page 1....\Beaches Habitat\180 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 700 700 0 I 0.080 655 14.0 Ox 0 VIFx 1 wri htsoft2017-Oct-1720:12:12 �C. 9 Right-Suite®Universa1201717.0.29 RSU09479 Page 2 n 5164. ...\Beaches Habitat\180 Sandy Beach Lane\1140L.rup Calc=MJ8 Front Door faces:SE , /c..A,p;y,, City of Atlantic Beach APPLICATION NUMBER Js1 ' t, Building Department (To be assigned by the Building Department.) r - v 800 Seminole Road n ;�.� �� Atlantic Beach, Florida 32233-5445 K-�S �� - O a 7 Phone(904)247-5826• Fax(904) 247-5845 A!on !P E-mail: building-dept@coab.us Date routed: I bI -.S In City web-site: http://www.coab.us OCT 2 6 2017 APPLICATION REVIEW AND TRACKING FORM Property Address: I(-6d S 4.nd-y e L Department review required Yes No Bui rng Applicant: a O l C,9 poi k abns-kru ...- Planning &Zoning ,t Tree mi I r Project: (\.Q_ 60\4 Ns-r�-a Sk i k.Q-(r\j. Public or Public Utilities Public Safety Fire Services Review fee $ ;77 Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Vr-proved. ❑Denied. I !Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONINGt••/ e�, (1 3 (? Reviewed by: Date: TREE ADMIN. Second� Review: ❑Approved as revised. ❑Denied. ['Not applicable P ORKS ` omme�nts: UBLIC UTILITIES k �� II- Z - '7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 , 201 Mr. Kayle Moore Public Utilities Director City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 Mr. Moore I have submitted a building permit application for the Triplex "A" located at: #172, 176, 180 Sandy Beach Lane,COAB (Blk.# 1,Lots#3,2, 1) Beaches Habitat will not be installing a fire sprinkler in this structure. In addition, according to our HOA agreement we will be installing an irrigation system for the common areas. Please give me a call (904-241-1222, or 334-1202) if you require any additional information. Sincerely, Ro. - .• i Construction Director C -�--, ,,(-- CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY 800 Seminole Road » Atlantic Beach,Florida 32233-5445AND EASEMENTS PLEASE SUBMI TCOMPLETE SETS OF PLANS904'247-5800 Date WITH APPLICATION. Fax 904-247-5845 Job Address 4.41 PERMIT# • Permitee: ISSUED BY THE CITY O t m`. j?Q✓ C.-••••S +cfiqrs. " .'V �fCs•4rZwlf Permittee Address: Z 1 Tele a ..s9 �� phone# o y _ ; RequestingPermission � tea'���� y- i Z° 4...to Construct: r(, LZ33 vti Location: ~ d`"v (Reference to Cross-Street) R•4• kJ 1. Applicant declares that prior to filing both aerial and underground that pro and the ccis srappte i locationsti here has non tascertained the location of all existing utilities A Letter of Notification was shown on the sketches. mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Bell South Telephone Company Ferrell Gas Yes( ) No Comcast Yes( ) No ( ) Date: ( ) Date: 2' Whenever necessary Yes ( ) No ( ) Date: ry for the construction, re Yes ( ) No ( ) Date: alteration or relocation of or any pair, improvement, maintenance, safe and e any all of osaidf all, p°rtion of said street or easement as determined by hereunder, poles, wires, pipes, cables or other facilities efficient operation,z shall be immediately removed from said street or easement the Director hereonof Public required the Director of Public and appurtenancesor Ppurtenances authorized 3 All work byatl meet CityWorks, and at the expense of the Permittee reimbursementunless reset or. l of Atlantic Beach or Florida De as Performed under the is Superintendent) located su-pjeryjsion of P Department of Transportation Standards and be 4. All materials and equipment � tom- orb.. 5. All city ated at shall su .-4- I Tele (Contractor's Project ty property shall be restored beto its original to condition as far as phone,. Pro and the manner satisfactoery Y the Director of Public Works or hi�y y- rto 6• A of plans covering detailstofc+ this installation Practical, in keepingdesignee. part sketchof this perms.covering ens sothin. with city specifications Riaht of Wa as well n. r copy ofr a recentnnserve % y are to be included with this an increase in im. This permittee shall commence actual construction in n• envious area ° � Y shall be made a more thanr60 days from daten of n owner's lot or n the cit permit approval, good faith with _ 8. make sure no haveoccurredtheIn the area that would days. If the be • It is Public Worksrto and agreed suthat the changes and permittee must review the beginning date is City's right, title and interest in the land rights bea entered permit with the extentDof the of toprivileges herein set out are affect the permitted construction. Cityassume all risk and indemnify, granted onlydtheto the of times, any and all irks, damage, fY, defend, upon and used s the holder,of, and Holder will, at all exercises by and save harmless the Cityof the holder of the aforesaid rights aexpensesarisingiiesin 9, AtlanticeBeach from and The Director of Public Works shall be any manner of the exercise immediately upon completion. notified or attempted twenty-four (24) hours prior to startle OWNER g work and again ( "v''v"'''•, KYLE MURRAY Signed: 4: G :°`�.1°`�'s Not:ory Public-State of Florida Before me this Date• a ��'i�� ( `•• • = State d:Florida, day of i. - Cmmission#FF 941841 Notary has personally appeared in the Count of D ( ��''k'�` A`° My omm.Expires Apr 2,2020 Public at Large,State of Florida, County of Duval. y u�l,',,,��"� " ,, Bonded through National Notary Assn. My commission expires: Produced Identification:�SOnaily Known: 1A.---- City of Atlantic Beach PUBLIC UTILITIES DEPARTMENT 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date 10 — Z - I"7 Project Address 80 },-) / ff�jg(hi_ .� Number of Units i Commercial Residential L Multi-Family ✓�j 1 f New Water Tap(s) & Meter(s) Meter Size(s) New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# et:_----s 17 U -z 3- pi tai-(piLak,1 (.., „..7 Water System Development Charge $ 2,0 i,t1.„2 P7'c'""J Sewer System Development Charge $ Sp G(S f Id - Water Meter Only $ d 8, Reclaim Meter Only $ Water Meter Tap $ Sewer Tap $ Cross Connection $ 50 , C50 Other $ TOTAL $ 2i , uV (Notes) APPROVED Kayle Moore, P.E. -7 Date I l ,� / (7 Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED 0---- if�r, City of Atlantic Beach APPLICATION NUMBER `Js , Building Department (To be assigned by the Building Department.) 800 Seminole Road K-&-s !9. _ h a 3, �t?. �r Atlantic Beach, Florida 32233-5445 l v Phone(904)247-5826 • Fax(904) 247-584`�CT tit?. g� E-mail: building-dept@coab.us 1 6 Date routed: I b1 (n City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1.%O S 0. . 3 it.0 lI\ • Department review required Yes No Bui mg Applicant: a O MO -1 POI k ObilS ttL Planning &Zoning Tree mi i r Project: Nib") ct tifir 5k t\ `2.-4('\JL Public WoWS- ) Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b : ,,,,,02,,,/,40, Date: 49 -Z/-17 TREE ADMIN. Second Review: A roved as revised. Denied. ❑ pp ❑ nNot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Permit Attachment of for Permit# issued 20 Atlantic Beach,FL 32233 , Owner's Name: ,e0.t�es u„ .: Property Address: �'p �g,,� R.E. #: 4��� 1. �a.y� Subdivision:_Q f r I REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT,issued on this by Atlantic Beach, Florida, a municipal corporation or day of ,20_, Florida, hereinafter refen-ed to as "CITY" and gamzed and existing under the laws of the State of 1��"`' si of Atlantic Beach, Florida, hereinafter referred to as "USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the ri enter upon the property of the City of Atlantic Beach for the ght to Beach Right-of-Way/Easement permit numbers noted above(copiespattached)escribed in the City of Atlantic This work is generally described as: I l p i ti Ut w4 1a.-o.. R. O. (J Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted subject to relocation or removal on thirty(30) days notice by CITY to the USER, said notice to USER be given by certified -mailshall be 'I return receipt requested, to the following address: The depositing of said notice of cancellation in the United States mail shall constitute the no cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. tace of The USER shall promptly make any and all necessary repairs to any facility erected or maintained exercise of the privilege herein granted and shall at all times maintain said facili m the ty in good and safe condition. In the event it is necessary for the CITY or the City's approved roe representative or other franchised utility to enter upon the above-described any and all material necessarily displa d during the action of maintaining, repairingthe USER shall replace e UR'g sole expense, adding to of the utilities and facilities of the CITY or franchise utility provide . ' operating, replacing, or The facilities allowed by the permit shall meet the current requirements of the City Code, BuildingCode Land Development Code, and all other land use and code requirements of the CITY,including s, City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Page 1 of 2 The USER, prior to making approval the City of ingnaaic changes from the approved plans and/or method, discretion from CITY, Beach,Public Works Department,for said change. must USER shall,a att the be requested to submit as-built drawings showing after the day the completion. The days This Permit shall insure the change within thirty(30) to the benefit of, and be binding upon, the USER and their assigns, • respective successors and and/orUSER shall meet the terms and conditions of this permit and to USER specifications,meet the to include utilities locate all of the applicable State and CITY laws rights-of-way and other public land. requirements and use all be saved waya harmless byUSER further agrees that the CI sofficers limitations/requirementssad liabilities the USER from any of the work herein and of officers and employeess said are hereby assumed by the USER.44. under the terms of this Permit and that all of DATED and SIGNED this day of 20 1 7 BY ' ' • • 'elty Owner dr� ( ;O,HY KYLE MURRAY _ Notary Public-State of Florida (to be signed in presencethe Notary) "__� Commission #FF 941841 of STATE OF d %.. ,4074 My Comm. Expires Apr 2, 2020 FLORIDA Bonded through National Notary Assn. 0 COUNTY OF DUVAL 7 On this —__ day of and for said County and ' 20, personally appeared State, PPeared before me, a Notary Public in and who executed the foregoing ,Atlantic Beach, Florida the property owner and voluntarily g g eIIt; who B ,known to me to be the persons of aril and for the uses and acknowledged to me � )described in purposes therein mentioned, that he or she executed the same freely Notary Public in for said County and State CITY OF ATLANTIC BEACH, FLORIDA a municipal corporation: ' Approved: ir., ! i/( ,Public ic '> or s Director 4 For Permits where city sidewalk is City Manager approval required: Pacted, Nelson Van Liere,City Manager Page 2 of 2 `f ' , CITY®F -. i ATLANTIC BEACH V, CONSTRUCTION PERMIT WITHIN CITY _. RIGHTS OF • w. - 800 Seminole Road WAY AND EASEMENTS `�°'»�1 Atlantic Beach,Florida 32233-5445 PLEASE SUBMI COMPLETE SETS OF PLANS WITH APPLICATION. 904-247-5800 Fax 904-247-5845 Date Job Address %-- Y � • PERMIT# lo My ISSUED BY THE CITY Permifiee: , Telephone# ay - 33 ?... C-^1s c fi.,. ► � - _ �S�r«e..f Permittee Address: Z a 'R1 my- � ia � Requesting Permission to Construct: r( L mss•1-w t tt. 3 3 Location: (Reference to Cross Street) Q R O 1. Applicant declares that prior to filing this a ` u , , �� pplication he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on A Letter of Notification was the sketches. mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Bell South Telephone Company Ferrell Gas Yes( ) No ( ) Date: Comcast Yes( ) No ( ) Date: 2 Yes ( ) No ( ) Date: Whenever necessary for the construction, repair, improvement Yes ( ) No ( ) Date: alteration relocationnecessary all, or any , maintenance, safe and efficient operation, Works n or or all of of poles, woes n of said street or easement as determined by ors shall be immediatelyremovedfrom said street orauthorized p azed, pipes, cables or other facilities and a the Director of Public requiredhereunder,bthe Directoreimofd Public appurtenances ren relocated authonzas authorized. Works, and at the expense of the ePe mitteeunolessreimbursement nas 3. All work shall meet City of Atlantic Beach or Florida De All kd underm the supervision e pSerformed located at -pj of e.vf Department of Transportation Standards and be 4. All materials ld and equipment at shall be su:est to n s� _ � ...-+ �.. (Contractor's Project 5. All city " I it c Telephone#: ty property shall be restored to its original condition as far as practical, in9vy 3 y" rte L Inspection by the Director of Public Works or his and the manner satisfactory ty. s• A of plans covering tofe ithis installation, as well keeping designee. P g with city specifications part sketchf this permitscovering detailse ns sotin. Riaht of Wa as, a copy af re recentnon surveyshall in made a an increase in im.erviotas area on owner's lot or in the cit 7. This permittee shall ommenceincludeactud tallsonstruction in this a lication. more than 60 days from mate of permit approval, good faith with da s. sure e haovatherm thaty If the withbthe date f 8. It is Public Worksrto and make sure no that changestha eprivilegesurrethearea must would affectw the permit the Director City's right, title and interest agreed in the land rights and entered upon hereinand used by the permitted to ttee tenofconstruction. times, set out are grantedoonly to the extent of the assume all risk of and indemnify, defend, and save harmless the eC t sof and the Holder will, at all against any and all loss, damage, exercises by the holder of the aforesaid rights and privileges. Atlantic Beach from and and cost of expenses arising in any manner of the exercise 9. The Director of Public Works shall be notified immediately upon completion. or attempted twenty-four (24) hours prior to startingwork and a OWNER / _ Yain 1_ : 4 P����Y P,,4 KYLE MURRAY / Signed: �!W Pg.' ' r'' �1't.S, Notary Public-State of Florida Before me t s �`j�� Date: p ''I'' Commission#FF 941841 State Of Florida, has pers. ally appeared f�� j ( '%� �� �d My Comm.Expires Apr 2,2020 Notary Public at Large,State of Florida, County of Duval. 'n the County of Duval, ( •',';�� F ` Bonded through National Notary Assn. My commission expires: --�Peisonally Known: J77 Produced Identification: 7 1.A,y;-4., City of Atlantic Beach APPLICATION NUMBER :is * L, Building Department artment (To be assigned by the Building Department.) 800 Seminole Road �S ��- — v a 1j7Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904) 247-5845 / �J;;i� E-mail: building-dept@coab.us Date routed: IC7l I« City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1%0 S ociNoN (.h L(\ • Department review required Yes No C1307Fing Applicant: a 0 l frka _l poi k abilzH'u.c,- (_Planning &Zoning f�' Tre Talf i n igtra r Project: tN.Q.*) ct,}�'a-C s n5`�4(1- t. •) EPublic V\Ior Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ['Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING 4, s� 1 l----- C"--1 / Reviewed by: Date: V TREE ADMIN. Second Review: A roved as revised. n pp ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017