172 SANDY BEACH LN - PERMIT (..._ , 01...m-r4., io iso CITY OF ATLANTIC BEACH �'ly 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ---o,____3 9INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0237 Description: new attached single-family home Estimated Value: 141425.8 Issue Date: 11/28/2017 Expiration Date: 5/27/2018 PROPERTY ADDRESS: Address: 172 SANDY BEACH LN RE Number: 173414 0170 PROPERTY OWNER: Name: BEACHES HABITAT FOR HUMANITY INC Address: 797 MAYPORT RD ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Address: 2768 STATE RD A1A#701 ATLANTIC BEACH, FL 32233 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. ,, City of Atlantic Beach APPLICATION NUMBER (fj fJ'. 1‘ Building Department (To be assigned by the Building Department.) 800 Seminole Road 5 11-0.3-31- ,it se Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845' D I '�0;tl9� l E-mail: building-dept@coab.us Date routed: S l iq City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: rtY St A9 &LV Li • Department review required Yes No Building Applicant: (DO l tvlo-k pori CAN SA-NAL:ED t) anning &Zoning Tree Administrator Project: VAAJ q{.}-ttcke4 \rj 2�--Vttn Ly t'u is Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ,PrApproved. I 'Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: i Date:( - 3c,---1 ) TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. [Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: [Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 S!.A/`1j?7J, City of Atlantic Beach APPLICATION NUMBER r}r '' n0 Building Department (To be assigned by the Building Department.) 800 Seminole Road ?..ES 11--0 -3� S t-, ' Si Atlantic Beach, Florida 32233-5445 ,� Phone(904)247-5826 Fax(904)247 584�`�+ 01119'' E-mail: building-dept@coab.us UCr 2 6 2017 Date routed: 101 3-S in City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: � and9tLhL.4 • Department review required Yes No Building Applicant: a0 140-1 pD(4 C AS-t(t,((� Dn = nmg &Zoning ` I Tree Administrator Project: IA-Lk) q{�- i t S(\�`Q--Vttcn ll E241-1- lic Worksublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. Denied. fNot applicable (Circle one.) Comments: BUILDING ' PLANNING &ZONING Reviewed Date:10- -/7 TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Permit Attachment of Permit# - _ for issued ,20— Atlantic Beach,FL 32233 Owner's Name: e0. l ll R.E. #: Property Address: -i Z 14 44 ----- Subdivision: -__Lot#/Block/434-t:6 ? v?� c,� tc � REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PE by Atlantic Beach, Florida, a municipal corporation issued on this day of Florida, hereinafter referred to as "CITY" and organized and existing20—, hereinafter referred to as "USER". under the laws of the State of of Atlantic Beach; Florida, WITNESSETH: grant That the CITY does hereby enter upon the roe the USER permission on a revocable basis as described herein the right to property rty of the City of Atlantic Beach for the Beach Right-of-Way/Easement permit numbers noted above(copi�ottachas ed describedse in the City of Atlantic This work is generally described as: ) L R. O. 4.)• Any facility maintained, repaired, erected,sun and/or installed in the exercise of the privilege given by certifiedothirty(30)days notice by CITY to the USE granted remainsh -mail, return receipt requested, said notice to USER shall be: �� • '� .} to the following 4 � �. g address: The depositing of said notice of cancellation in the United States mad shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER'S The USER shall promptly make anyproper address. exercise of the shall prprivilomptly herein and all necessary repairs to any facility granted and shall at all times maintain said facility or maintained in the tY in good and safe condition. In the event it is necessary for the'CITY or the City's approved representative or other any and all the above-described e-d necessarily displacedperty of the CITY, the USER shall replace at the USER'S sole expense, addingnyto of the utilities and rily rthe CITY theoaction of maintaining,i repairing, operating, franchise utility Provider. g, replacing, or The facilities allowed by the permit shall meet the current requirements Land Development Code, and all other land use and code requiremets of the CITYr ty Code, Building Codes, City Code Section 19-7 1'�including (h)which states'Driveways that cross sidewalks: City sidewalks may not replaced with other materials, but must be r laced replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." the Page 1 of 2 The USER, prior to making approval from the City of Atlantic changes from the approved plans and/or method, discretion of the Beach,Public Works Department,for said chane. a USERt shall,a written CITY, be requested to submit as-built drawings showing after the day of completion. g The at the This e g wing the change within thirty (30) days permit shall insure to the benefit of, and be binding upon the USER a assigns, • and thea respective successors and USER shall meet the terms and conditions of this e • and/or specifications, to include utilities locate permit and to all of the applicable State and CITY law rights-of-way d/or and other public land. requirements and use limitations/requirementss shall be saved harmless oy the USER from USER further agrees that the CITY s officrs ad liabilities areaherebyas any of the work herein under the t and its officers and employees said assumed by the USER. terms of this permit and that all of said D" TED and SIGNED this day of ,20' By: 1' ' _ , e .5„arre, KYLE MURRAY Property Owner' ' c�° ;.' Notary Public -State of Florida (to be signed in . esence of the No %� o MyCComm. ExpiresFA 9r�2,2020 1841 t STATE OF FLORIDA, ) �QOF"" �, 8ondedthroughNationaINotaryAssn. 0 COUNTY OF DUVAL G� On this day of and for said County and , 20 , personally appeared ppeared before me, a No and who executed � Atlantic B the �'Public in the foregoing each,Florida,known to me to be property owner of and whovoluexecuted and for the uses and went' who acknowled the person(s)the same freely in purposes therein ged to me that he or she executed the same freely mentioned. Notary Public in for said County and State CITY OF ATLANTIC BEACH, FLORIDA, a municipal corporation: Approved: �' ' • „i - blic ' orks Director For Pe e s �ewets where city sidewalk is impacted, City Manager approval required: Nelson Van Liere,City Manager Page 2 of 2 � TY OF ATLANTIC BEACH =� •,,,,.:,,,...;_-= :�; CONSTRUCTION PERMIT �'-—� RMIT WITHIN CI 80o Seminole Road 71'RIGHTS OF WqY � At A !antic Beach,Florida 32233.55 AND EASEMENTS PLEASE SUBNIICOMPLETE SETS OF PLANS WITH APP 904-247-5600 Date 1C LIGATION. Fax 904-247-5845 Job Address t. ..Z _ S PERMIT# Permitee: l°I '"'� �...h �-••. �a'` — " G d fF g ISSUED BY THE CI fi�, vL�.,� n' Permittee Address: - .Se�+e..f Z .�1- '� Telephone# a. v RequestingP " �10.��4,= 3 y- 1 t a � Permission to Construct: , zZ33 ti Location: "` d.-f (Reference to Cross-Street) 0• uJ 1. Applicant declares that prior ©��� �}� S''`�_ both aerial and underground pro to filingthe accurate I ` L , this application he has ascertained. A Letter of Notification was locations are shown onthe location of the sketches, all existing utilities, mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Bell South Telephone Company Ferrell Gas Comcast Yes( ) No ( ) Date: Yes Yes ( ) No ( ) Date: 2. Whenever necessaryeYes( � No ( ) Date: alteration or relocation of all, or anyconstruction re ( Date: Works, anypair, improvement or alla ofn saidf portion of said street or easement asfdeter hereunder poles, wires, , safe and efficient operation, shall be immediately removed pipes, cables or other facilities mined b required by the Directore of Public from said street or ease by the Director of Public authorized. Works and appurtenances 3. , and at the easement or reset l s authorizedis All work shall meet City expense hereon as P of the Permittee unless reimbursement is performed the of Atlantic Beach or Florida Superintendent) located supervision of • �t* P{Department of Transp0dation Standards and be 9' All materials and equipment� � '^� 5. All city ted shall be su .r (Contractors tY eropertn shall e hal to its erect to inspectiio as far` TelephoneWorks#: Project 6. and the manner satisfactory by the Director of Public or his designee. A of plans covering bent restored city. SI- ins t as practical, in keeping with city specifications pat sketchf this permit overn of this 7. PB this Are to of included with this a as well as, a co Thisan increase in im. copy of a recent serve permittee shall commence actual construction in eN1Ous area on , Y shall be made a more than 60 licat1On• owner s lot or in the cit Publicdays from date of good faith with 8. Works permit approval, then days. m the It is understood to make agreed-that su the changes and permittee have occurred in the must review the beginning date is City's right, title and interest the land rights bea entered upon Permit with the Dof of toarea that would affect the permitted construction. times, assume all risk of and indemnify, privileges herein set out are P and used bygranted onlydto the extent of the any and all loss,kdamage, fY, defend, and save the holder, and the Holder will, againstea by the all the and cost of ex harmless mannere Cityat all 9expenses arising in any of Atlantic Beach from and The Director of Public Works shall brights and of the exercise exercis immediate, uponnotified Pnvlleges_ or attempted (24) hours prior to starting work OWNER and again - Signed: � � (...4., ( -�o}°'r',"•,,��� KYLE MURRAY Before me this / -'( ,t� ( rNotary Public-State of Florida State Of Florida, has IF day of /..Date: II II - CommissionreFF 941841020 Nota Personally appeared �� the County %•�+ � +�- My Comm.Ex Notary Public at Large,State of Florida of Duval, Aires Apr Notary Assn My commission expires: Coen �'�'°�� `��� Bonded through National Notary ASsn. County of Duval. Produced IdentL9cation.rsonaAy Known: 1.--- l SyLvfk, City of Atlantic Beach APPLICATION NUMBER rS r '' "` S� Building Department (To be assigned by the Building Department.) m 800 Seminole Road p LS 1�_� -31- ",- Atlantic Beach, Florida 32233-5445 F—�' Phone(904)247-5826 • Fax(904) 247-5845 lO I '.�J,3 v� E-mail: building-dept@coab.us Date routed: I i' City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM «'r SG& $PJL . (1') Department review required Yes No Property Address: � h Building V Applicant: a 0 k titD-kt f o(4 ConS-11,4_0;m = arming &Zoning Tree Administrator Project: 111.1-3 444.(,ked Sl� e-- r amt[y Pyhlic Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ['Not applicable (C - - -.) Comments: BUILDI PLANNING & ZONING �/1�, ll' 7-.700Reviewed by: ill. . Date: TREE ADMIN. Second Review: ['Approved as revised. ['Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: # 172 Sandy Beach Lane, COAB, 32233 Permit Number: Legal Description: 38-2529E-7.41B De Castro Y Ferrr Grant PT RECD O/R 16531-2248 Parcel # Blk: 1 Lot: 3 Floor Area of Sq.Ft. Sq.Ft Valuation of Work $110,000 Proposed Work heated/cooled 1172sti. non-heated/cooled 188 Class of Work(circle one): New (X) Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No(X) N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: Construct attached two story Triplex single family homes Property Owner Information: Name: Beaches Habitat for Humanity Address: 797 Mayport Rd City Atlantic Beach State FL Zip 32233 Phone#904-241-1202 E-Mail or Fax#(Optional)#904-241-4310.rpeterson@beacheshabitat.org Contractor Information: Company Name:201 Mayport Construction Management, LLC _Qualifying Agent: Robert Peterson Address: 2768 State Rd.AlA#701 City Atlantic Beach State FL Zip 32233 Office Phone 904-595-5798 Job Site/Contact Number_904-334-1202 Fax# State Certification/Registration#CGC 1506666 Architect Name&Phone# 3LAVsay.ruL. D J e4-1o4 '104- 10'4 - 8(.c22 Engineer's Name&Phone# G1yr c C Ll- (AO- tx 21 Gl Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void f work is not commenced within six(6)months,or if construction or work is suspended or abandoned for apenod of six 6)months at any time after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells, Pools,Furnaces,Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I herebycertify that I have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type ofworkwill be c,-plied with whether speci�d herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other •'eral,state,or local law regulating construction or the performance of construction. • Signature of Owner = / Signature of Contractor Print Name X66 ¶"i€)!'7 Print Name Swo toliend sub ' ed efore e Sworn tYQand subscribed before me this ay of ,T20 l 1 this Q o Day of ‹er r ,20 C 7 Not.ry P � 30 , ,,Pu • KYLE MURRAY `,a,„,„�;�-' i uOIaKYLE MURRAY ;r° �' `� Notary Public-State of Florida ?o` <�'; Notary Public-State of Florida • Commission # FF 941841 Revised 01.26.10 • Commission#FF 941841 • My Comm. Expires Apr 2,2020 ( 9 %�, ��� off' My Comm.Expires Apr 2,2C' I °”, F, ,, Bonded through National NotaryAssn. ` ��,,,,,,„,s'' g , ��� � Bonded through National Notary OFFICE COPY• 0 DO NOT WRITE BELLOW- OFFICE IUSE ONLY A.pphca. e Co.es: 2010 FLORIDA BUILDING CODE Review Result circle one : • Approved Disapproved Approved-w/ Conditions Review Initials/Date: a- 7-ave m I Development Size Habitable Space /No E.F Non-Habitable $' impervious area • 4scellaneous Information ►ccupancy Group -�3 ype of Construction V 6 amber of Stories 2. ning District 2 Cr x. Occupancy Load 0 Sprinklers Required • )d Zone A ditions/Comments: PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA OFFICE COPY Project Name: OceanGate: Tri-plex"A" Permit # fr&S/7-C)?3'7 Project Address: # , 176, 180 Sandy Beach Lane, COAB, 32233 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.or . Category/Subcategory Manufacturer Product Description Limitation of Use State # Local # A. EXTERIOR DOORS 1. Swinging Masonite Steel Door FL4904 2. Sliding 3. Sectional 4. Roll up Clopay Garage Door- HDG FL5684.10 5. Automatic 6. Other B.WINDOWS 1. Single hung Atrium Single Hung Window FL11834.10 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11.. Dual action 12.. Other PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA C. PANEL WALL 1. Siding James Hardie Cemplank siding FL13192.1 2. Soffits Crane Vinyl Soffit FL2495-R1 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco Acrocrete Synthetic finish coat 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles GAF 30 yr architectural FL10124 2. Underlayments RhinoRoof Syn. Underlayment FL15216 3. Roofing fasteners 4.Nonstructural metal roof Millenia Metals Form rolled metal FL5211.2 R4 5. Built-up roofing 6. Modified bitumen Certainteed Flintlastic SA FL2533 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coasts 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other E. SHUTTERS 1. Accordion Shutter Shield _ Accordion FL9569.1 2. Bahama 3. Storm panels Madden Mfg. Storm Panels FL5329.1 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor Simpson Strong- H16S FL1423.6 Tie MTS 12 FL474.253 2. Truss plates MiTek Industries Truss Plates FL2197 3. Engineered lumber Tus-Joist- Engineered Lumber FL1630 Weyerhauser 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall v PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturer, product description and State approval number for the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected,they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Authorized Project Agent: Robert Peterson; Director of Construction i (Contractor or Design Professional) (Print Name) (' •:•. ure)_ — Company Name: Beaches Habitat for Humanity Mailing Address: 797 Mayoort Road PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA City: Atlantic Beach State: FL Zip Code: 32233 Telephone Number: ( 904) 241-1222 Fax Number: (904 ) 241-4310 Cell Phone Number: ( 904) 334-1202 E-mail Address: rpeterson@a,beacheshabitat.org 171 n ui Eecs FORM R405-2014 OFFICE COPY RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include \ This checklist 'r3 A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification(usually 4 pages/may be greater). Energy Performance Level(EPL)Display Card(one page) "l Mandatory Requirements(three pages) Required prior to CO for the Performance Method: Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) A completed Envelope Leakage Test Report(usually one page) If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCSB v5.1 8/24/2017 1 12:36 PM Page 1 of 1 ,OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-TRIPLEX-OUTSIDE-A-L-172SB Builder Name: BEACHES HABITAT Street: 172 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State.Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner. Jurisdiction: 261300 Design Location: FL,Jacksonville County:: DUVAL(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft' b.Frame-Wood,Common R=19.0 498.67 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (572.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 572.00 ft' 6. Conditioned floor area above grade(ft2) 1140 b.N/A R= ft' Conditioned floor area below grade(ft2) 0 C.N/A R= ft 2 11.Ducts R ft2 7. Windows(130.0 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH: 1st Floor 6 165 a U-Factor: Dbl,U=0.30 130.00 ft' SHGC: SHGC=0.30 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 23.5 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.252 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (568.0 sqft.) Insulation Area EF:0.920 a Slab-On-Grade Edge Insulation R=0.0 568.00 ft' b. Conservation features b.N/A R= ft' None c.N/A R= ft' 15.Credits Pstat Total Proposed Modified Loads: 28.69 Glass/Floor Area: 0.114 PASS Total Baseline Loads: 32.85 I hereby certify that the plans and specifications covered by Review of the plans and :•'pFTKE.ii ;;:••:; this calculation are in compliance with the Florida Energy specifications covered by this *•%..- dr..• O4:••. Code. calculation indicates compliance .147,-,',`• =.',,��`.. with the Florida Energy Code. filo?, '••. " PREPARED BY: ,v t.;a 'Eke? Before construction is completed %I =-,' ' .V. `aF DATE: 8/.244//7 this building will be inspected for t _e^ - ;j compliance with Section 553.908 *`.,.. I hereby certify tha his building,as designed, is in compliance Florida Statutes. :.% ... ... ` � ` with the Florida En- • Cos' G'Op1 ?+' OWNER/AGENT: allf_ �. . .. BUILDING OFFICIAL: �r DATE: - - DATE: ti - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 this project requires an envelope leakage test report with envelope leakage no greater than 3.0 ACH50(R402.4.1.2). 8/24/2017 1:12 PM EnergyGaugee USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4 _• I / FORM R405-2014 PROJECT Title: HABITAT-TRIPLEX OUTSID Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1140 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 0 Street: 172 SANDY BEACH LA Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer ---- Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume — 1 Block1 1140 9120 SPACES —Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 568 4544 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 572 4576 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area ___ Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 0 568 ft2 ---- 0.2 0 0.8 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch * Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 603 ft2 96 ft' Medium 0.85 No 0.9 No 0 18.4 '// ATTIC I Type Ventilation Vent Ratio(1 in) Area RBS IRCC -,,,, ► 1 Full attic Vented 300 572 ft' N N CEILING �Y - * ___Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 1st Floor 30 Batt 572 ft' 0 Wood 8/24/2017 1:12 PM EnergyGauge®USA•v5.1 -Section R405.4.1 Compliant Software Page 2 of 4 ---- -"--"7"."" Vrt` I / FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below -. __ Or t____7n.--_Walt T.ype-.-- ---- --- -Space _Et -----EL_ln Ft In Arna RVallia Fraction Ahepr Grafi°h V 1 SE Exterior Frame-Wood 1st Floor 19 20 0 8 160.0 ft' 0.23 0 75 0 ..\I 2 SW Exterior Frame-Wood 1st Floor 19 31 2 8 249.3 ft' 0.23 0.75 0 V 3 NW Extenor Frame-Wood 1st Floor 19 20 0 8 160.0 ft' 0.23 0.75 0 Nt 4 NE Neighbor Frame-Wood 1st Floor 19 31 2 8 249.3 ft' 0.23 0.75 0 N1 5 SE Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft' 0.23 0.75 0 N 6 SW Extenor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft' 0.23 0.75 0 \i 7 NW Exterior Frame-Wood 2nd Floor 19 20 8 160.0 ft' 0.23 0 75 0 8 NE Neighbor Frame-Wood 2nd Floor 19 31 2 8 249.3 ft2 0.23 0.75 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area -- -- - - Ft In Ft In 1 SE Insulated 1st Floor 'Metal .46 3 6 8 20 ft' 2 S Insulated 1st Floor Metal .46 3 6 8 20 ft' WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang . V _ # Ornt ID_Frame Panes NFRC U-Factor SHGC _ Area Depth Separation Int Shade Screening \V 1 SE 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft' 6 ft 0 in 1 ft 0 in Drapes/blinds None V 2 SE 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft' 6 ft 0 in 1 ft 0 in Drapes/blinds None N 3 SW 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None Ni 4 SW 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 SE 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft' 6 ft 0 in 1 ft 0 in Drapes/blinds None 6 SE 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 7 SW 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None `I 8 SW 6 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None Ni 9 NW 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None NNI 10 NW 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # _ Scope Method SLA CFM 50 EtA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000152 456 25.03 47.08 .1446 3 HEATING SYSTEM V _ # System Type Subtype Efficiency Capacity __ _ __ Block__Ducts _ -\1 1 Electric Heat Pump None HSPF:8.5 23.5 kBtu/hr 1 sys#1 8/24/2017 1:12 PM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 4 I I I FORM R405-2014 COOLING SYSTEM - ..\1V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 24 kBtu/hr 720 dm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF V None None • ft' DUCTS / —Supply— --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 let Floor 6 165 ft' 1st Floor 196 ft= Default Leakage 1st Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling X Jan X Jan X Feb X Mar Apr (eb Mar X r [XX May [(XX]]Jun M Jul X Aug X Sep X Oct I:cc Nov 'X)Dec Ve ting X Jan [XX�Feb IXX�Mar !Xi XApr [X]MaMay (x)Jun Jul IX�AuJun Jul g X�Sep X' Oct XNov XNov 'X))DDec ec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(W0) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 8/24/2017 1:12 PM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4 1 ' FORM R405-2014 ENERGY 'PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index,the more efficient the home. 172 SANDY BEACH LANE,ATLANTIC BEACH , FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft' b.Frame-Wood,Common R=19.0 498.67 ft' 3. Number of units,if multiple family 1 C.N/A R= ft' 4. Number of Bedrooms 3 d.N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 572.00 ft' 6. Conditioned floor area(ft') 1140 b.N/A R= ft' 7. Windows** Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.30 130.00 ft' 11.Ducts R ft' SHGC: SHGC=0.30 a.Sup: 1st Floor,Ret:1st Floor,AH: 1st Floor 6 165 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 24.0 SEER:15.00 SHGC: d. U-Factor N/A ft' SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.252 ft. a.Electric Heat Pump 23.5 HSPF:8.50 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 568.00 ft' a.Electric Cap:40 gallons b.N/A R= ft2 EF:0.92 c N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building . ;• ''�T14ESTq ' Construction through the above energy saving features which will be installed(or exceeded) o. 4�''•. in this home before final inspection. Otherwise, a new EPL Display Card will be completed kj�ry,°_, `,,'I f as O�:• based on installed Code compliant features. ? ;,,�R },f"' ,,•::• ..-7. 'ail • Builder Signature: 3 __ Date: - / '04 i °a "`." o q z�,�� -; Address of New Home:j7 Z City/FL Zip: J3 A-6 `-.•. • _• ,,4�SS Cpb igN".�` w 32- 2-3__ *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/24/2017 1:12 PM • EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 i FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 172 SANDY BEACH LANE Permit Number. ATLANTIC BEACH ,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy Florida law [Section 553 9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1 1 and R402 4 1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402 4.1 1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction Where required by the code official,an approved third party shall inspect all components and verify compliance. ▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing. 1 Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust.intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed, 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMANVDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential All recessed 1, luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system )53 R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that.except dunng defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load )31 R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2 7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553 993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be'substantially leak free"by either of the following' 1 Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2 Rough-in test.Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w g (25Pa)across the system,including the manufacturer's air handler enclosure.Ail registers shall be taped or otherwise sealed during the test If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area Exceptions 1 The total leakage test is not required for ducts and air handlers located entirely within the building envelope 2 Duct testing is not mandatory for buildings complying by Section R405 of this code. 8/24/2017 1.12 PM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3 V.- t - T -------- 't I FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 9 R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 A inches(89 mm)in the hot water distribution line and cold water line located as close as possible )51 to the storage tank. R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls ▪ R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions.for the type of equipment installed Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors. and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1 Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2 Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1 15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load 8/24/2017 1:12 PM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3 I j FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal. rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1 Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load 2 When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice 0 R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403 6 1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options' 1 A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas 2 A variable capacity system sized for optimum performance during base load periods is utilized. R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15 The energy requirements for portable spas shall be in accordance with ANSI/APSP-14 0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21 56 Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1 Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps N 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights 4 R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19 Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed 8/24/2017 1:12 PM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3 J FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: HABITAT-TRIPLEX-OUTSIDE-A-L-172SB Builder Name BEACHES HABITAT Street. 172 SANDY BEACH LANE Permit Office. DUVAL COUNTY City,State,Zip. ATLANTIC BEACH FL,32233 Permit Number. Owner: Jurisdiction 261300 Design Location FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed The junction of the top plate and the top or exterior walls shall be sealed. \� Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. J Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawispace walls \v Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or \� unconditioned space shall be sealed. Narrow Cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls Fireplaces shall have gasketed doors 8/24/2017 1.12 PM EnergyGaugej USA-v5 1 -Section R405.4 1 Compliant Software Page 1 of 1 I I .441. wrightsoft. Manual S Compliance Report Job: 172 SB Lane Entire House Bate: 10.17-2017 By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 17489 Btuh Entering coil DB: 76.9°F Outdoor design WB: 77.0°F Latent gain: 3181 Btuh Entering coil WB: 63.6°F Indoor design DB: 75.0°F Total gain: 20670 Btuh Indoor RH: 50% Estimated airflow: 700 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Sensible capacity: 18041 Btuh 103%of load Latent capacity: 4022 Btuh 126%of load Total capacity: 22063 Btuh 107%of load SHR: 82% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 20999 Btuh Entering coil DB: 68.4°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 700 cfm Output capacity: 18689 Btuh 89%of load Capacity balance: 30 °F Supplemental heat required: 2310 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 700 cfm Output capacity: 4.7 kW 77%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. /�sL+l� wrightso ' Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-1720:14:19 ft ...\Beaches Habitat\172 Sandy Beach Lane11140R.rup Calc°MJ8 Front Door faces:SE Page 1 4 Project Summary Job: 172 SB Lane W rlgh#$oftDate: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WV.W.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Notes: 172 Sandy Beach Lane Desi• n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17499 Btuh Structure 14574 Btuh Ducts 3500 Btuh Ducts 2915 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20999 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17489 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2100 Btuh Ducts 1081 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1140 1140 Equipment latent load 3181 Btuh Volume(ft3) 9920 9920 Air changes/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 20670 Btuh Equiv.AVF(cfm) 74 38 Req. total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A00300 Cond 25HBC524A00300 AHRI ref 9154698 Coil FX4DNF025L AHRI ref 9154698 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 16800 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 7200 Btuh Temperature rise 31 °F Total cooling 24000 Btuh Actual air flow 700 cfm Actual air flow 700 cfm Air flow factor 0.033 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point= 30°F Backup: Input=5 kW, Output= 16145 Btuh, 100 AFUE Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrll htSOft 2017-Oct-1720:14:19 g Rig Universal 2017 17.0.29 RSU09479 Page 1 ..\Beaches Habitat\172 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE - wrightsoft• Right-J® Worksheet Job: 172 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name 2 Exposed wall Entire House Kitchen 3 Room height 204.0 ft 25.0 ft 4 Room dimensions 8.0 ft 8.0 ft heaUcool 5 Room area 1240.0 /t' 154.0 ft'14.0 x 11.0 ft r I I I Ty Construction U-value Or I HTM Area (ft') Loadr number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) (Btuh) I oreaperimeter Load (ft) (Btuh) I 1 Heat I Cool I Gross I N/P/S I Heat I Cool 1 Gross I N/P/S Heat Cool 6 W 12E-Osw 0.068 ne 2.55 1.43 4961 454 1159 652 0 0 0 0 --0 1D-c2ow 0.570 ne 21.38 39.24 6 0 128 235 0 0 0 0 G 1D-c2ow 0.570 ne 21.38 39.24 21 0 445 816 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 15 0 315 578 0 0 0 0 1112E-Osw 0.068 se 2.55 1.43 320 239 609 343 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 31 4 667 1213 0 0 0 0 1D c2o 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 15 15 315 268 0 0 0 0 D 1100 0.390 se 14.62 11.78 20 20 298 240 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 496 496 1265 712 88 88 224 126 Vr_ 12E-Osw 0.068 nw 2.55 1.43 320 248 632 356 112 92 234 131 1D-c2ow 0.570 nw 21.38 39.24 31 0 667 1224 0 0 0 D 1100 0.390 nw 14.62 11.78 41 41 597 481 20 20 298 240 C 16B-30ad 0.032 - 1.20 1.72 264 264 317 454 64 64 77 C 160-lad 0.112 - 4.20 6.01 496 496 110 2083 2983 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 760 125 4622 0 154 25 927 0 6 I c)AED excursion I I 0 208 Envelope loss/gain 14434 109101 17601 3991 12 a) Infiltration b) Room ventilation 3065 744 0 376 91 0 0 13 Internal gains: Occupants @ 230 4 920 0 Appliances/other 2000 0 2000 Subtotal(lines 6 to 13) 17499 14574 2136 2491 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 394 141 15 Duct loads 17499 14574 2530 2632 20% 20% 3500 2915 20% 20% 506 526 I I Total room bad I 209991 174891 Air required(cfm) I I 700 7001 I I 31036 01 31581 1261 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Atk. 414- Wrigti1t50ft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-17 20:14:19 ...\Beaches Habitat\172 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE Page 1 4 wrightsoft Right-J® Worksheet Job: 172 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Utility 2 Exposed wall Bath1 10.0ft 9.0ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 4.0 ft 6.0 x 9.0 ft 5 Room area 24.0 ft' 54.0 ft' I I I I i r Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') I Load number (Bt uh/ft'-°F (Bt uh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross I N/P/S Heat I Cool I Gross I N/P/S Heat Cool I 6 V/ 12E-Osw 0.068 ne 2.55 1.43 32 32 82 46 72 66 168 95 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 6 0 128 235 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 11 1 D c2on 1D-c2ow 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 1100 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 48 28 70 40 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 1100 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 12 12 14 21 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpt 0.989 - 37.09 0.00 24 10 371 0 54 9 334 0 I 6 I c)AED excursion -301 143161 Envelope loss/gain I I 8361 317 I 6301 12 a) Infiltration 150 36 135 33 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 986 353 766 349 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 0 0 14 Subtotal 986 -353 719 237 0 0 1485 585 15 Duct loads 20% 20% 0 0 20% 20% 297 117 I Air Total rrequired(coom loafmd) I l l OI OI I I 1782 7281 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right-Suitee Universal 2017 17.0.29 RSU09479 2017-Oct-17 20:14:19 Page 2 ...\Beaches Habitat\172 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE ` - wrlghtsofts Right-J® Worksheet Job: 172 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Pllan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Great Meth 2 Exposed wall 55.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 378.0 ft 6.0 x 5.0 ft 5 Room area 378.0 f t' 30.0 f t' I I r i Ty Construction U-value Or 1 HTM Area (ft') LoadArea (ft') Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) (Btuh) I or perimeter (ft) II (Btuh) II Heat 1 Cool Gross I N/P/S Heat I Cool I Gross I N/P/S I Heat Cool 1 6 V✓ 12E-Osw 0.068 ne 2.55 1.43 112 102 259+ 146 40 40 102 57 . -G 1 D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 10 0 222 408 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 1112E-Osw 0.068 se 2.55 1.43 160 110 281 158 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 10 c2o 0.570 se 21.38 24.12 15 11 315 355 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 15 15 315 268 0 0 0 0 D 1100 0.390 se 14.62 11.78 20 20 298 240 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 168 168 428 241 0 0 0 0 hD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 84 84 101 144 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 378 55 2040 0 30 5 185 0 1 61 c)AED excursion 1 1 -167 -6 Envelope loss/gain 1 42591 17941 I 2871 521 12 a) Infiltration 826 201 b) Room ventilation 75 18 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 5086 1995 363 70 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 235 45 14 Subtotal 5320 2040 363 70 15 Duct loads 0 0 20% 20% 1064 408 20% 20% 0 0 1 AO requi ed(ad) i I I 6385 2448 981 I 1 OI 010 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W � �t 01 Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-17 20:14:19 tr ...\Beaches Habitafl172 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE Page 3 A+ wrightsoft Right-J® Worksheet Job: 172 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M WIC Master 2 Exposed wall 12.0 ft 23.0 ft 3 Room height 8.0 ft heaVcool 8.0 ft heat/cool 4 Room dimensions 7.0 x 5.0 ft v. 13.0 x 10.0 ft 5 Room area 35.0 ft' 130.0 ft' Ty Construction U-value OrHTM Area (ft ) Load Area (ft') Load number (Btuh/11'-°F I (Btuh/ft') I or perimeter (ft) (Btuh) I I or perimeter (ft) (Btuh)` IHeat l Cool I Gross I N/P/S Heat Cool Gross I N/P/S Heat Cool 6 W 12E-Osw 0.068 ne 2.55 1.43+ 40 40 102 57 0 0 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 . -0 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 1112E Osw 0.068 se 2.55 1.43 56 56 143 80 104 73 186 104 1 D clow 0.570 se 21.38 38.87 0 0 0 0 31 4 667 1213 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 0 1 D clow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 D 1100 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 80 80 204 115 hD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 35 35 42 60 0 0 0 0 C 165-7ad 0.112 - 4.20 6.01 0 0 0 0 130 130 546 782 F 22A-tpl 0.989 - 37.09 0.00 20 7 254 0 0 0 0 0 6 I c)AED excursion -19 If 402 Envelope loss/gain I I 5411 1791 ` 1603 I 26116 12 a) Infiltration 180 44 346 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 721 223 1948 3160 $ Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 184 177 321 309 14 Subtotal 905 400 2269 3469 15 Duct loads 20% 20% 181 80 20% 20% 454 694 roo1086 480 2723 4163 AirTotal requiredm (cfmload) I I f 36l 19I f 91 I 1671 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2017-Oct-17 20:14:19 Right-Suite®Universal 2017 17.0.29 RSU09479 Page ...\Beaches Habitat\172 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE • 44- wrightsof Right-J® Worksheet Job: 172 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,FI 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name 2 Exposed wall M 0Linen 1B0d 3 0 ft 21.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 3.0 x 5.0 ft 10.0 x 11.0 ft 5 Room area 15.0 ft' 110.0 ft' r r I I r r Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-°F (Btuh✓ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross I N/P/S Heat I Coot Gross I NIP/S Heat Cool 1 6 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 0 Of 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 11 1D-c2ow 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 1 D clow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 1100 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 88 88 224 126 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 80 64 164 92 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 16 0 333 612 1100 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 120 1.72 15 15 18 26 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 110 110 462 662 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 1 61 c)AED excursion 186 Envelope loss/gain i 1 181 241 1 11841 16781 12 a) Infiltration 0 0 316 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 18 24 1500 1985 Less external bad 0 0 0 0 Less transfer Redistribution 0 0 0 0 -18 -24 177 168 14 Subtotal 0 0 1677 2153 15 Duct loads 20% 20% 0 0 20% 20% 335 431 I I ATotalrreq roomuired load( ) l I I I OI OI I I 20121 25831 icfrn67 10311 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrfghtsoft Right-Suite®U niversal 2017 17.0.29 RSU09479 2017-Oct-17 20:14:19 ...\Beaches Habitat\172 Sandy Beach Lane11140R.rup Calc=MJ8 Front Door faces:SE Page 5 4 wrlghtsoft- Right-J® Worksheet Job: 172 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Pan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bed 2 Loft 2 Exposed wall 21.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 11.0 ft 1.0 x 146.0 ft 5 Room area 110.0 ft' 146.0 f t' I I Ty ' Construction U-value Or I HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-'F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)1 Heat I Cool Gross I N/P/S Heat I Cool I Gross WP/S Heat Cool 1 6 VJ 12E-Osw 0.068 ne 2.55 1.43 88 73 187 105 112 102 259 146 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 0 0 0 0 . -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 10 0 222 408 -C' 1D-c2ow 0.570 ne 21.38 39.24 15 0 315 578 0 0 0 0 1112E-0sw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 0 0 0 0 10 clow 0.570 se 21.38 24.12 0 0 0 0 0 0 0 0 1 D clow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 D 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 0 0 0 0 HD12E-Osw 0.068 nw 2.55 1.43 80 64 164 92 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 16 0 333 612 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 110 110 462 662 146 146 613 878 F 22A-tpl 0.989 - 37.09 0.00 44 8 312 0 56 5 199 0 6 I c)AED excursion -69 -56 Envelope loss/gain 1 17731 19801 1 12941 1376 12 a) Infiltration 316 77 210 51 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2089 2287 1504 1427 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 442 420 -1504 -1427 14 Subtotal 2531 2707 0 0 15 Duct loads 20% 20% 506 541 20% 20% 0 0 Air Totalrequireroomd load(cfm) J 1 1 303011 3238OI I 1 01 0I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsert 2017-Oct-17 20:14:19 Right-Suite®Universal 2017 17.0 29 RSU09479 Page ...\Beaches Habitat1172 Sandy Beach Lane11140R.rup Calc=MJ8 Front Door faces:SE 4 wrFghtsoft Right-J® Worksheet Job: 172 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web.WWW.NORTHFLORIDAAIR.COM 1 Room name Bath 2 2 Exposed wall 9.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 5 Room area 54.0 ft' I 1 I I f Ty Construction U-value Or HTM Area (ft') Load Area number (Bt uh/ft'-"F (Bt uh/ft') I or perimeter (ft) I (Btuh) I or perimeter I Load f Heat Cool I Gross N/P/S I Heat Cool I Gross I N/P/S I Heat I Cool I 6 V/ 12E-0sw 0.068 ne 2.55 1.43 0 0 0 0 -G 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 -G 1 D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 -1' 1D-c2ow 0.570 ne 21.38 39.24 0 0 0 0 1112E-Osw 0.068 se 2.55 1.43 0 0 0 0 1D-c2ow 0.570 se 21.38 38.87 0 0 0 0 1Dc2ow 0.570 se 21.38 24.12 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 O 1100 0.390 se 14.62 11.78 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 72 72 184 103 HD12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 1100 0.390 nw 14.62 11.78 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 54 54 65 93 C 16B-7ad 0.112 - 420 6.01 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 6 I c)AED excursion I I I 248 1781 I , I I If Envelope loss/gain 12 a) Infiltration 135 33 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 384 211 Less external load 0 0 Less transfer 0 0 Redistribution 398 378 14 Subtotal 782 589 15 Duct loads 20% 20% 156 118 Air Total roomrequired loa ( ) d l I I 9381 7281 07 I I I cfm I 1111 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wri9flts0}t' Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-1720:14:19 ...\Beaches Habitat1172 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE Page 7 N 1s loor Utility Kitchen • .. hfrt4 ~ 126 cfm 6 " 4 " 10 " rA 6 " 41 hi a cfm Mech • A 106 cfm 12 " Sup Riser •'• 12 " 6 " Great • A 106 cfm Job#: 172 SB Lane Florida Air Service & Engineeringscare: :as Performed for: Page 1 Beaches Habitat 150 Hilden Road 308 RightSukee thioertal 2017 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:14:38 WWW.NORTHFLORIDAAIR.COM ...t\172 Sandy Beach Lane\1140... N 1 2nd Floor Bed 3 Bed 2 12 x 10 ,�� 12 x 10 103 cfr 130 cfm 6 " 6 " Bath 2 • •' 12q-0fifer 4 " 7 " 12 10 , I, 167cfm ML -en Master 36 cfn M WIC Job#: 172 SB Lane Florida Air Service & Enineerin Scale: 1 :as Performed for: 9� 9 Beaches Habitat Page 2 150 Hilden Road 308 RightSuite®Universal 2017 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:14:38 \NWW.NORTHFLORIDAAIR.COM ...t\172 Sandy Beach Lane\1140... Duct System Summary Job: 172 SB Lane 4 wrightsoft Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 1140R 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply/return available pressure 0.125/0.125 in H2O 0.125/0.125 in H2O Lowest friction rate 0.100 in/100ft 0.100 in/100ft Actual air flow 700 cfm 700 cfm Total effective length (TEL) 126 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 1-A h 1782 59 28 0.100 4.0 Ox 0 VIFx 17.1 100.0 st3 Bath 2 h 938 31 28 0.100 4.0 Ox 0 VIFx 11.1 110.0 st2 Bed 2 c 3248 101 130 0.100 6.0 0x 0 VIFx 13.9 110.0 st2 Bed 3 c 2583 67 103 0.100 6.0 Ox 0 VIFx 15.0 110.0 st2 Great-A h 3192 106 49 0.100 6.0 Ox 0 VIFx 16.2 100.0 st3 Great-B h 3192 106 49 0.100 6.0 Ox 0 VIFx 25.2 100.0 st3 Kitchen c 3158 101 126 0.100 6.0 Ox 0 VIFx 12.2 100.0 st3 M wlc h 1086 36 19 0.100 4.0 Ox 0 VIFx 15.8 110.0 st2 Master-A c 4163 91 167 0.100 7.0 Ox 0 VIFx 11.4 110.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 373 252 0.100 685 10.0 0 x 0 VinlFlx st1 st1 Peak AVF 373 252 0.100 685 10.0 0 x 0 VinIFIx st2 Peak AVF 327 448 0.100 570 12.0 0 x 0 VinlFlx Bold/italic values have been manually overridden wri htsQft' 2017-Oct-17 20:14:20 9 Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 ...\Beaches Habitat\172 Sandy Beach Lane11140R.rup Calc=MJ8 Front Door faces:SE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb1 Ox 0 700 700 0 0.080 655 14.0 Ox 0 VIFx 49 Wri htsoft' 2017-Oct-17 20:14:20 Right-Suite®Universal 2017 17.0.29 RSU09479 Page 2 ...\Beaches Habitat1172 Sandy Beach Lane\1140R.rup Calc=MJ8 Front Door faces:SE ( T?i City of Atlantic Beach APPLICATION NUMBER 1v , , Building Department (To be assigned by the Building Department.) • 800 Seminole Road LS1 —pa 3-1- ;_., p F—� � w •:4, Atlantic Beach, Florida 32233-5445 nP \ Phone(904)247-5826 • Fax(904) 247-58d5'T 2 6 2017 IO I a P---0 110' E-mail: building-dept@coab.us Date routed: S I l'-4 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: t�. 1-- Sandy e cit\Le • Department review required Yes No Building Applicant: a 0 l 14O.- pori 115-l(kcADO ' anning &Zoning 1 Tree Administrator Project: lAt.)-J akit sii\s4 2-- aal ti Pu----.c Works Public Utilities Public Safety Fire Services Review fee $ 5 b Dept Signature 4"-----, Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. fNot applicable (Circle one.) Comments: BUILDING PLANNING &ZONING _ /`� /t/ i 3 Reviewed by: Date: �� TREE ADMIN. Second Review: 'Approved as revised. (Denied. nNot applicable P WORKS, Comments: PUBLIC UTILITIES /1 — Z- 17 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 e , 201 Mr. Kayle Moore Public Utilities Director City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 Mr. Moore I have submitted a building permit application for the Triplex "A" located at: #172, 176, 180 Sandy Beach Lane, COAB (Blk. # 1, Lots #3, 2, 1) Beaches Habitat will not be installing a fire sprinkler in this structure. In addition, according to our HOA agreement we will be installing an irrigation system for the common areas. Please give me a call (904-241-1222, or 334-1202) if you require any additional information. Sincerely, Roe- 'eterson, Construction Director------ City of Atlantic Beach PUBLIC UTILITIES DEPARTMENT s( ,:'.g Sandpiper Lane l Atlantic Beach, FL 32233 �/-y. (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date I) - Z - 17 Project Address / 7 2 pO v (.5 ----717"AL 64,u t= Number of Units ( Commercial Residential Multi-Family ' New Water Tap(s) & Meter(s) Meter Size(s) *c-{ New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# 3 17 — 0 2 37 Water System Development Charge $ n ( S Sewer System Development Charge $ No S y C Water Meter Only $ / es-, (f0 Reclaim Meter Only $ Water Meter Tap $ Sewer Tap $ Cross Connection $ 50 C OU Other $ TOTAL $ 23s—, (50 (Notes) APPROVED Kayle Moore, P.E. Date (((37(2 Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED OFFICE COPY , 201_ Mr. Dan Arlington Building Official City of Atlantic Beach 800 Seminole Rd. Atlantic Beach, FL 32233 Dan Attached are the following materials in support of Beaches Habitat application for the building permit : Triplex "A", Block#1 Lots#3, 2,1 #172, 176, 180 Sandy Beach Lane,COAB 1) One(1) copy of the Building Permit Application each unit 2) Two(2) copies of roof truss plans 3) Two(2) copies of HVAC Energy Sheets 4) Two(2) copies of the Florida Product Approval form 5) One(1) copy of recorded Notice of Commencement 6) One(1) copy of letter to Kayle Moore regarding fire sprinlder/irrigation systems. 7) Five(5) copies of the Construction Management Plan 8) Two(2) copies of architectural plans 9) Two(2)copies of structural engineering plans 10)Five(5) copies of civil engineering plans 11)Two(2)copies R.O.W. Permit Please let me know if any additional information is required. Thank you, Sincerely, Robert .e e Construction Director 904.334.1202 attachments NOTICE OF COMMENCEMENT OFFICE COPY Perm`r IS #Re-S 17 (°a 3 r?j 0.238-, va 3 9 State Florida Tax Folio No. County of Duval To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 38-2S-29E-7.41 B De Castro Y Ferrer Grant PT Recd 0R/16531-2248 (Block# 1 Lots#3,2, 1) Address of property being improved: (#172, 176, 180 Sandy Beach Lane.),Atlantic Beach, FL 32233 General description of improvements:construct 2 story single family attached triplex Owner: Habitat for Humanity of the Jacksonville Beaches Address: Atlantic Beach, FL 32233 Owner's interest in site of the improvement: 100% Fee Simple Titleholder(if other than owner): Name: �41 Contractor:201 Mayport Construction Management LLC ( FL State Certified General Contractor#CGC1506666) Address:2768,Atlantic Beach, FL 32233 f j3, Phone No.: 904-334-1202 Fax No.: 904-241-4310 Surety(if any): Address: Amount of bond$: Phone No.: Fax No.: Name and address of any person making a loan for the construction of the improvements: Name: Address: Phone No.: Fax No.: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: Robert Peterson, do 201 Mayport Construction Management, LLC Address:2768 State Rd A1A, Atlantic Beach, FL 32233 Phone No.:904-334-1202 Fax No.: In addition to himself,owner designates the following person to receive a copy of the Lienors Notice as provided in Section 713.06(2)(b), Florida Statues. (Fill in at Owner's option) Name: Address: Phone No.: Fax No.: Expiration date of Notice of Commencement(the expiration date is one(1)year form the date of recording unless a different date is specified): Warning to owner: Any payments made by the owner after the expiration of the notice of commencement are considered improper payments under Chapter 713, Part 1, Section 713.13, Florida Statutcc,and can result in your paying twice for improvements to your property. A notice of commencement must be recorded and posted on the job site before the first inspection. If you intend to obtain financing,consult with your lender or attorney before commencing work or recording your notice of commencement. • THIS SPACE FOR RECORDER'S USE OWNED 6 Signed: Date: l Before me this day of in the County of Duval, State of Florida, has personally appeared b,Q_ Joni?S Notary Public at Larg-, to - o F •ri•-, o o P My commission expir: _ . Personally Known: • , . , , ,. or Produced Identificati• E antil WSJ, "--111My Comm.Expires Apr 2,202C Doc#2017221991,OR BK 18132 Page 633, °°' '°'''" Bonded through National Notary Assn Number Pages: 1 Recorded 09/28/2017 at 11:50 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING$10.00 v--