Loading...
176 SANDY BEACH LN - PERMIT iLA�y . .„ �Y , t 4110. , CITY OF ATLANTIC BEACH li �" } 800 SEMINOLE ROAD yl ATLANTIC BEACH, FL 32233 "!1_111 c-)1 INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY ATTACHED MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES17-0238 Description: new attached single-family home Estimated Value: 145131.8 Issue Date: 11/28/2017 Expiration Date: 5/27/2018 PROPERTY ADDRESS: Address: 176 SANDY BEACH LN RE Number: 173414 0165 PROPERTY OWNER: Name: BEACHES HABITAT FOR HUMANITY INC Address: 797 MAYPORT RD ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: 201 MAYPORT CONSTRUCTION MANAGEMENT Address: 2768 STATE RD A1A#701 ATLANTIC BEACH, FL 32233 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. s1JJ'Jr City of Atlantic Beach APPLICATION NUMBER �� Building Department (To be assigned by the Building Department.) ,. 800 Seminole Road ��S 0 M 3 Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 • Fax(904)247-5845 A;rti9j/ E-mail: building-dept@coab.us Date routed: 1o/3-s1 ri City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 11- (0 sctAdy in.LA . Department review required Yes No Buildin Applicant: QDl UA.kP0A 0-01\S-V6l.(AD,n Planning &Zonin Tree Administrator Project: A� ct+foto5\• (\1.Q,-siiit<y ,(..L..5"-bjic Works Publicilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: /Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING P ANNING &ZONING Date: 1 3G_1Reviewed by:v TREE ADMIN. Second Review: Approved as revised. Denied. pp ❑ ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 sr\IJr,J City of Atlantic Beach APPLICATION NUMBER r Building Department (To be assigned by the Building Department.) 800 Seminole Road vAtlantic Beach, Florida 32233-5445 I–ES T. Phone (904)247-5826 • Fax(904)247-580CT 2 6 2017 1d A,0111c% I- E-mail: building-dept@coab.us Date routed: O `Ii City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: a (p mo ()A1 . Department review required Yes No Buildin� Applicant: QD ( b Pt 0-01\S-kfikrAon CElanning &tonin Tree Administrator Project: (\e -) a'.f'Eac,INtd S\ (r1„Q,—�u�ntyublic Works Publicities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: WApproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: 47__. Date: d® .1717 TREE ADMIN. Second Review: Approved as revised. pp ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. I 'Denied. [Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Permit Attachment of Permit# issued 20_----_ for -_— Atlantic Beach,FL 32233 Owner's Name: Property Address: /7 to Subdivision: #: �� tZ ehc�# I REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROAC HIVIENT PERMIT,issued on this by Atlantic Beach, Florida, a municipal corporation ora day of Florida, hereinafter referred to asg nized and existing under the laws of the State of "CITY" and ��� s —' �---� of Atlantic Beach, Florida, hereinafter referred to as "USER". That the CITY does herebyWITNESSETH: enter upon grant the USER permission on a revocable basis as described herein the right to P the property of the City of Atlantic Beach for the purpose as described in the Beach Right-of-Way/Easement eg permit numbers noted above (copies attached). City of Atlantic This work is generally described as: • Ii ► i .(tiUtWk. Lez$. R. Q. cJ. Any facility maintained, repaired, erected, and/or installed in the exercise of nted remains subject to relocation or removal on Hurt y(30) days notice by CITY to the USER,said nolo e to�e USER shall be given by certifiedmail —I 1 yy� k ! °, return receipt requested, to the following address: 4 The depositing of said notice of cancellation in the United States mail cancellation and the burden upon USER to keeshall constitute p informed of USER's proper address. the notice of the CITY The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property any and all material necessarily displaced duringCITY, the USER shall replace at the USER's sole expense, adding to of the utilities and facilities of the CITY or franchi of the action maintaining, utility provider. repairing, operating, replacing, or The facilities allowed by the permit shall meet the current requirements of the Land Development Code, and all other land use and code requirements of the CITY, City Code, Building Codes, City Code Section 19-7(h) which states "Driveways that cross sidewalks: City including with other materials, but must be replaced with smooth concrete left natural in c existing and adjoining sidewalks may not be replaced J ening sidewalks. color so that it matches the Page 1 of 2 The USER, prior to making any changes from the approval from the City of nan Beach,anPublic Works Department, discretionpvalof the CITY, bAtlantic o submit approvedeartplans and/or method P i-tiiient, for said chane ' must obtain written after the day completion. as-built drawings showingg The USER shall, daysat e This Permit shall insure to the benefit of, and be binding the change within thirty(30) assigns• upon, the USER and their respective • USER shall meet the to successors and terms and conditions of this permit and to all of the applicable and/or specifications, to include utilities locate re and/or sway and other public lde quirements and ns/ State and CITY laws be saved h USER further a use and its officers and armless by the USER from agrees that the CITY its officers and publicof liabilities are herebyassumed byany of the work herein under the terms of employees shall the USER. this permit emit and that all of said 'TED and SIGNED this__L day of 20,v 0 BY: a1�, .�. P KYLE MURRAY • erty Owner , `�+= Notary Public-State of Florida (to be signed in pr;.ence of the Notary) 1�. Commission FF 2,20 My Comm.Expires Apr 2,2020 ''' STATE OF FLORIDA v'fti me ceded through National Notary Assn COUNTY OF DUVAL On thisttij—Aday of and for said County nd 20 ,/personally appeared ppeared before me, a Nota and who the foregoingAtlantic Beach, Florida the o Public in instrument ,known to me to beproperty owner of and whovoluexecuted and for the cand u , who acknowledged the Puled the sameafre in purposes therein ged to me that he or she executed the freely mentioned. Notary Public in for said County and State CITY Ol F ATLANTIC BEACH, FLORIDA, a municiP corporation: Approved: f 4/Public or s "'rector For Permits where i ty sidewalk is impacted City Manager approval required: ' Nelson Van Liere, City Manager Page 2 of 2 dr �''� CITY OF ATLANTIC r, '� �,<�,�}__���� CONSTRUCTION PERMIT � = RMIT WITHIN CI ,' ,r� 800 Seminole Road TY RIGHTS ��''�� � Atlantic Beach FloridaF WAY AND EASEMENTSPLEASE MiTCOMPLETE SETS OF PLANS WITH APPLICATION. 90`1-247-5800 Date FaX 904-247.5845 PERMIT# ISSUED BY THE CITY Job Address 6 i Permitee: lO �e.it t;.,� — _ SVra.c.fin. �V"4, Permittee Address: 141..64,150.4 aid o _ Z 94 Telephone# Requesting P " ti 0,...4\-:- 3 y- / t o Permission to Construct: t F , 2_1_332_1_3333 9 ermi v. Location: (Reference to Cross-Street) ' ,,,..-Ir u Q•a kJ 1. Applicant declares that ©c�� �+� S'"S'both aerial aerial and underground and the �` filingor to accuratethiu applicationhe has on tascertained the location of all locations are shown on the sketches. A Letter of Notification was existing mailed to the following utilities, Jacksonville Electric Authority Utilities/Municipalities: Bell South Telephone Company Ferrell Gas Comcast Yes( ) No ( ) Date: Yes( ) No ( ) Date: 2. Whenever necessaryYes( ) No ( ) Date: alteration or relocatioof all, or any Yes( ) No ( ) Date: Works, construction, repair, improvement any or all ofn said portion of said street or eamaintenance hereunder Poles, wires, easement as determined' safe and efficient operation, shall be immediately pipes, cablesnappurtenances the Director of Public c s required by the Directore of Publicemoved from said street orheaseacenes re authorized. Works, and at the a reePt or ree Unl ss r imbout reimbursement is 3. All shall expense of the P rated hereon City of Atlantic Beach Permittee unless reimbu sement as All workfrkd under meet the supervision or Florida De Superintendent) located at p'ervision of . Department of 4. All materials and e Transportation Standards and be equipment at shall be�u ''4- it't- .n� 5. All cityect to I (Contractor's property shall be to its anginal condition as ` Telephone o: Project and the manner satisfactory Y the Director of Public °y- y- iia 6. A of restored tthe ci far as Works or his specifications pei plans of installation Practical, in keeping with cityP gree. part sketch permit.coveringndetailsens sof thin. hll eC caters Rtgho this are to be included as Well as, a copy ofr a recentnoserve �' This an increase in im.ervious . permittee shall commence actutahconstruction in area on ow Y shall be made a more than 60 is a I►cat�on- tier's lot or in the cit Public days from date of Works to permit approval, then good faith with 8. It is understood and agreed that the and permittee � days. If the be changessure no have occurred in the must review the beginning date is City's right,dertitle and interest in the land rightstbe enteredpermit with the Director fof area that would affect the times, assume all risk f and the indemnify, upon herein set out are permitted construction. against and all loss, damage, upon and used granted only to the extent of the exercises byfY, defend, and saveby the holder, and the Holder will, at all the holder of the aforesaid righcosts andpenses arisingharmless the City of Atlantic Beach from and 9' against any of Public Works shall be privileges. in any manner of the exercise or attempted i The i_Director upon ubl cletio r notified ges. twenty-four (24) hours prior to OWNER starting work an ain "'r�'': KYLE MURRAY Signed: CiL, ,�►� �e, Before �; �C r',I� ( A ' `� Notary PubNc-State of Floridame this da oDate: _ Commission#FF 941841State Of Florida, ru -dhas ersonallya y -- in the Count of ( '�',',, °�' My Comm.Expires Apr Notary Assn P Notary Public at Large, PPdared y Duv� ,°Fts's My commission expires:State of Florida,County of Duval. "" "'��, Bonded through National Notary Assn. Aires: PeProduced Identification: rsonally Known: ,,i-.5.7.tu47„, ,,, City of Atlantic Beach ...„, t f PUBLIC UTILITIES DEPARTMENT ;--, ;' 1200 Sandpiper Lane Atlantic Beach, FL 32233 `..... �f (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date // — Z — / 7 Project Address / 7Cre (99-ri r y a7 * 6.4i �t Number of Units / Commercial Residential t Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) 4 New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application# c--.-,---5 - 0 2 3 M qt./( - Water System Development Charge $ �(/& Sewer System Development Charge $ A/o S C (5 Water Meter Only $ / Q 5T oz_) Reclaim Meter Only $ Water Meter Tap $ Sewer Tap $ Cross Connection $ 50 (-5& Other $ TOTAL $ 23s , csd (Notes) APPROVED Kayle Moore, P.E. I -(=c1/ Date ( ((3/(7 Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED i1-4i City of Atlantic Beach APPLICATION NUMBER �S r " . Building Department (To be assigned bythe BuildingDepartment.) J ` 800 Seminole Road g p ) ILES ( 1 - p 3- KV - �� Atlantic Beach, Florida 32233-5445 a 3 Phone(904)247-5826 • Fax(904)247-5845 I�fe� 01110- E-mail: building-dept@coab.us OCT 2 6 2017 Date routed: ! 1 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: a cQ dy � ..in . Department review required Yes No /� Building Applicant: QD \- D �(10 ik rNsV `;a),() Planning &tonin Tree Administrator Project: A Q,iJ a 44 aU.d 5\ ()IL M:ly ublic Works Pubic i i ies Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPL ATION STATUS Reviewing Department First Review: Approved. ['Denied. ['Not applicable (Circle one.) Comments: BUILDING /� PLANNING &ZONING Reviewed by: 14. 11/(1" Y!/vim Date: TREE ADMIN. Second Review: Approved as revised. ❑Denied. F 'Not applicable PI ORKS Comments: UBLIC UTILITIES //— i — F-7 PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. ❑Denied. I 'Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 , 201 Mr. Kayle Moore Public Utilities Director City of Atlantic Beach 1200 Sandpiper Lane Atlantic Beach, FL 32233 Mr. Moore I have submitted a building permit application for the Triplex "A" located at: #172, 176, 180 Sandy Beach Lane, COAB (Blk. # 1, Lots # 3, 2, 1) Beaches Habitat will not be installing a fire sprinkler in this structure. In addition, according to our HOA agreement we will be installing an irrigation system for the common areas. Please give me a call (904-241-1222, or 334-1202) if you require any additional information. Sincerely, Ro.- 'eterson,_ Construction Director -_ 3 t�"� f ,/,-;4' 1TY OF ATLANTIC BEACH << E H �,-� �� ;r CONSTRUCTION PERMIT h 800 Seminole Road WITHIN CITY RIGHTS OF WAY AND EASEMENT_,_,y S PLEASE SUBMICOMPLETE SETS OF PLANS 904-247.5800 Date WITH APPLICATION. Fax 904-247.5845 - 3 y- � to Job Address Me— jq� r`E' C�1 PERMIT# Permit Telephone#l°t e"�� ISSUED BY + 1?"i}• C-�S�'rs..e.ftrs, Vy���S� THE CITY Permittee Address: -I ) a... �cid .94eta-ioti�; mooy 4...._ F , LZ33 Requesting Permission to Construct Location: `1 °l v-1 u (Reference to Cross-Street) � Q•�• IA) , 1. Applicant declares that prior to filing . i`"� both aerial and underground pro and the ccisraappte li locations ons here has Sownon tascertained. the location of all existing utilities A Letter of Notification was shown on the sketches. mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Bell South Telephone Company Ferrell Gas Yes ( ) No ( ) Date: Comcast Yes ( ) No ( ) Date: 2. Yes( ) No ( ) Date: Whenever necessary for the construction Yes ( ) No alteration of or any ( ) Date: repair, improvement Works, n orny relocationor all of saidf all, portion of said street or easement ats determined b poles wires, pipes, cables or other facilities safe and efficient operation, d hereunder, shall be immediatelyremovedrequiredby from said street or easementand appurtenances y the Director hereonof Public authorized. the Director of Public Works, and at the expense of thepor resetorsreimbursement relocated is 3• All work shall as meet CityPermittee unless performed of Atlantic Beach or Florida D under the supervision Department of Superintendent) at of ems- (� Transportation Standards and be 4. All materials and equipment � I(L,�, IAN 5. located atshall be su .h f (Contractor's All city property shall e restored to its original ect to inspection at TelephoneWorks#: Project and the manner satisfactory by the Director of Public or his designee ►to L 6. A of ry to the city, far as practical, in keeping plans of this installation p 9 with cityspecifications Pat sketchf permit.coveringrndetailsens showin, a Ri rt o this as well as, a copy ofr a recentnoowner's %. .e to 6e included with this a an increase in inn e This permittee shall commence actual construction inn rvlous area on ow survey shall be made a more than 60 days f the lot or inthe cit y from date of permit approval, good faith with 8. to surenoof permit haveoccurred]n the area thatdays. If the beginning It is Public Worksrand make sued that the eand permittee must would the dato is City's right,rtitle and interest in the land rights bea entered upon andpermit with the t ofDirectortheof toprivileges herein set outdate affect the permitted construction. yassume all risk and indemnify, granted onlydtheo the extent of against and all irks, damage, defend used the City of, and Holder will, at all against any byg and cost of expensespand save harmless manner of the exercisexc Beach Item and gethe holder of the aforesaid rights and privileges. The Director of Public Works shall be arising in any immediately upon completion. notified or attempted twenty-four (24) hours prior to starting work and again OWNER • Signed: - JJ y '�� ,.4µr"'��.,� KYLE MURRAY me , • Date: /� ! ' -`�: 2ks.. Notary Public-State of Florida Before Of Florida, has erso day of ,� •' Commission FF 941841 ppeared Notary Public at Large,State of Florida,County of Duval.I. the aunty of Duval, �;�, ��� �� State ,,���1 My Comm.Expires Apr 2,2020 My commission expires: ',,,,P.-. Bonded through National Notary Assn. Produced Identification:Personally Known: l •S,Ali: City of Atlantic Beach APPLICATION NUMBER 61-14,. Building Departmentiii: (To be assigned by the Building Department.) 800 Seminole Road ��S C _ 0 �� Atlantic Beach, Florida 32233-5445 a 3 K:. JPhone(904)247 5826 Fax(904)247 5845 IOiesI ,3 Vi - E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 11- (Q 3 UML . Department review required Yes No Buildin (/ Applicant: Q L UV o�� 0..Cl1SAr�.LADn Planning &Zoni Tree Administrator Project: Ae.),‘) ct.44a()N (1 -ii-M 5� (k.Q,— <<y c�blic Works C Public5ilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: roved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLA ONING Reviewed by: Date: l 7-010t7 TREE ADMIN. Second Review: Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 BUILDING PERMIT APPLICATION OFFICE COPY CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: # 176 Sandy Beach Lane, COAB, 32233 Permit Number: S�� O '-3 Legal Description: 38-2529E-7.41B De Castro Y Ferrr Grant PT RECD O/R 16531-2248 Parcel #Blk: 1 Lot: 2 Floor Area of Sq.Ft. Sq.Ft Valuation of Work $110,000 Proposed Work heated/cooled 1212 sq. non-heated/cooled 172 Class of Work(circle one): New (X) Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) (circle one): Commercial Residential If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No(X) N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: Construct attached two story Triplex single family homes Property Owner Information: Name: Beaches Habitat for Humanity Address: 797 Mayport Rd City Atlantic Beach State FL Zip 32233 Phone#904-241-1202 E-Mail or Fax#(Optional)#904-241-4310,rpeterson@beacheshabitat.org Contractor Information: Company Name:201 Mayport Construction Management, LLC Qualifying Agent: Robert Peterson Address: 2768 State Rd. AlA#701 City Atlantic Beach State FL Zip 32233 Office Phone 904-595-5798 Job Site/Contact Number_904-334-1202 Fax# State Certification/Registration#CGC1506666 Architect Name&Phone# Sa\,arve _ Ove rbc CtU 4- 104 " e(a 2 42) Engineer's Name&Phone# ,Mtck-hG4 \ G\.1,.,.,-, \loris ol\>-1-l.p C30 - Cs 2-19 Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void tf work is not commenced within six(6)months,or if construction or work is suspended or abandoned for a�penod of six(6)months at any time after work is commenced. I understand that separate permits must be secured for ElectricalWork, Plumbing,Signs, Wells,Pools, Furnaces, Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type o1 work will be co ied with whether speci red herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other fe ral,state,or local law regulating construction or the performance of construction. Signature of Owner< Signature of Contractor 71� Print Name (04� � Print Name (I#.. 4-+ P A-t✓ar-Yr 1.k.. Swopt 0 and sub =.ed before.1 e Sworn to and subscribed beforg me this ,,Day of __,/, ,, i 20 this 7044—Day of cy ,20 I t 1 - e-----t Notary 1•s • , ' `Y P KYLE MURRAY KYLE MURRAY ,':° `�'- Notary Public State of Florida ( r° • `N`�• Notary Public•State of Florida evised 01.26.10 •' Commission #FF 941841 '. •-• Commission#FF 941841 .1.4-fait..,-.0$ My Comm.Expires Apr 2,2020 , ''�4 �,,,, My Comm.Expires Apr 2,202' ' ,,,, Bonded through National Notary Assn. 'um,, Bonded through National Notary As, OFFICE COPY DO NOT WRITE BELOW- OFFICE I LSE ONLY Applica• e Co•es: 2010 FLORIDA BUILDING CODE Review Result circle one : Approved Disapproved Approved-w/ Conditions Review Initials/Date: _ ___ty___ / —7rdo/7 bevelopment Size Habitable Space 35-8" S rNon-Habitable 7 n pervious area diseellaneous Information ccupancy Group 2-3 ype of Construction v a amber of Stories 2 ning District Q6- x. &Lx. Occupancy Load Sprinklers Required )d Zone thtions/c omments: • PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA OFFICE COPY Project Name: OceanGate: Tri-plex"A" Permit# R&S /7- Project Address: #172, 1 , 180 Sandy Beach Lane, COAB. 32233 As required by Florida Statute 553.842 and Florida Administrative Code 9B-72, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.or4.. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Steel Door FL4904 2. Sliding 3. Sectional 4. Roll up Clopay Garage Door- HDG FL5684.10 5. Automatic 6. Other B. WINDOWS 1. Single hung _ Atrium Single Hung Window FL11834.10 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed _ 6. Awning 7. Pass-through 8. Projected 9. Mullion 10. Wind breaker 11.. Dual action 12.. Other PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA C. PANEL WALL 1. Siding James Hardie Cemplank siding FL 13192.1 2. Soffits Crane Vinyl Soffit FL2495-R1 3. EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8. Membrane • 9. Greenhouse 10. Synthetic stucco Acrocrete Synthetic finish coat 11. Other D. ROOFING PRODUCTS 1. Asphalt shingles GAF 30 yr architectural FL10124 2. Underlayments RhinoRoof Syn. Underlayment FL15216 3. Roofing fasteners 4. Nonstructural metal roof Millenia Metals Form rolled metal FL5211.2 R4 5. Built-up roofing 6. Modified bitumen Certainteed Flintlastic SA FL2533 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coasts 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other E. SHUTTERS 1. Accordion Shutter Shield Accordion FL9569.1 2. Bahama 3. Storm panels Madden Mfg. Storm Panels FL5329.1 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor Simpson Strong- H16S FL1423.6 _ Tie MTS 12 FL474.253 2. Truss plates MiTek Industries Truss Plates FL2197 3. Engineered lumber Tus-Joist- Engineered Lumber FL1630 Weyerhauser 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturer,product description and State approval number for the products used on this project, it is the Contractor's or Authorized Agent's responsibility to have a legible copy of each manufacturer's printed instructions, along with the list above, on the job site available to the inspector. The products listed below did not demonstrate product approval at time of plan review. I understand that before these products can be inspected,they must be submitted for review for code compliance and approved by a Plans Examiner. This form will be revised to include each new product in the categories listed above and will be highlighted to indicate the new products and required information. Authorized Project Agent: Robert Peterson; Director of Construction (Contractor or Design Professional) (Print Name) ( attire Company Name: Beaches Habitat for Humanity Mailing Address: 797 Mayport Road PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA City: Atlantic Beach State: FL Zip Code: 32233 Telephone Number: (904) 241-1222 Fax Number: (904 ) 241-4310 Cell Phone Number: (904) 334-1202 E-mail Address:_rpeterson@beacheshabitat.org aFMCE COPY FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include This checklist �I A Form R405 report that documents that the Proposed Design complies with Section R405 3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page) and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). Energy Performance Level(EPL)Display Card(one page) Mandatory Requirements(three pages) Required prior to CO for the Performance Method: Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) A completed Envelope Leakage Test Report(usually one page) If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCSB v5.1 8/28/2017 10.58-06 AM Page 1 of 1 OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HABITAT-TRIPLEX-INSIDE176SB Builder Name: BEACHES HABITAT Street: 176 SANDY BEACH LANE Permit Office: DUVAL COUNTY City,State.Zip: ATLANTIC BEACH ,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville County:: DUVAL(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1920.0 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Common R=19.0 1392.00 ft' b.Frame-Wood,Exterior R=19.0 528.00 ft' 3 Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (605.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft 6. Conditioned floor area above grade(ft2) 1358 b.N/A R= ft2 Conditioned floor area below grade(ft') 0 c. N/A R= ft2 11.Ducts R ft' 7. Windows(105.1 sqft.) Description Area a.Sup: 1st Floor,Ret: 1st Floor,AH:Attic 6 165 a. U-Factor. Dbl.U=0.30 105.06 ft' SHGC• SHGC=0.30 b. U-Factor N/A ft' 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d U-Factor N/A ft2 a.Electric Heat Pump 24.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth 3.049 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8 Floor Types (605.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft' b. Conservation features b.N/A R= ft2 None c N/A R= ft' 15.Credits Pstat Glass/Floor Area: 0.077 Total Proposed Modified Loads. 25.90 PASS Total Baseline Loads: 28.40 I hereby certify that the plans and specifications covered by Review of the plans and :••��j 1E Sti '-.. this calculation are in compliance with the Florida Energy specifications covered by this s'�pti. O,;':, Code. calculation indicates compliance h . ,,,.,, with the Florida Energy Code. ' ,,,,,„„‘p,„..Ni. ';,• ,�f0st PREPARED BY: __L-L). Before construction is completed -__fie0•' DATE: - _ _-__ az 11 _-_ this building will be inspected for ___ •_e, ,'a f compliance with Section 553.908 i . • a I hereby certify that is buildin as compliance designed, is in Florida Statutes. with the Florida Ener Co g COb wT4$'• OWNER/AGENT: BUILDING OFFICIAL: iti)". DATE: - I DATE: -- ii.-74017 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 this project requires an envelope leakage test report with envelope leakage no greater than 3.0 ACH50(R402.4.1.2). - Compliance requires a roof emittance test in accordance with R405.7.2 8/28/2017 10:58 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 4 zea, I .1 , FORM R405-2014 PROJECT Title: HABITAT-TRIPLEX-INSIDE1 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1358 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units. 1 Worst Case: No PlatBook: Builder Name: BEACHES HABITAT Rotate Angle: 0 Street: 176 SANDY BEACH LA Permit Office: DUVAL COUNTY Cross Ventilation: No County: DUVAL Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Multi-family FL, 32233 New/Existing. New(From Plans) Comment CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site IECC 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium ~ BLOCKS Number Name Area Volume 1 Blockl 1358 10864 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 1st Floor 805 6440 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 553 4424 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 190 ft 0 605 ft2 ____ 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 638 ft2 100 ft2 Medium 0.75 No 0.9 Yes 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC —N- 1 Full attic Vented 300 605 ft2 N N CEILING V # Ceiling Type _ Space R-Value Ins Type Area Framing Frac Truss Type _ Ni 1 Under Attic(Vented) 1st Floor 30 Batt 605 ft2 0 Wood 8/28/2017 10:58 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 2 of 4 1 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below S Ornt TO Wall Type Space R-Value _Ft . In _ Ft In _Area R.Vatue Frartinn Ahcnr C;raria%_ V 1 N Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft2 0.23 0.75 0 N 2 E Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft' 0 23 0.75 0 N4 3 S Exterior Frame-Wood 1st Floor 19 16 6 8 132.0 ft' 0.23 0 75 0 4 W Neighbor Frame-Wood 1st Floor 19 52 0 8 416.0 ft' 0.23 0.75 0 N . 5 N Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft' 0.23 0.75 0 ✓ 6 E Neighbor Frame-Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0 7 S Exterior Frame-Wood 2nd Floor 19 16 6 8 132.0 ft' 0.23 0.75 0 8 W Neighbor Frame-Wood 2nd Floor 19 35 0 8 280.0 ft2 0.23 0.75 0 DOORS • V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated 1st Floor •Metal .46 3 6 8 20 ft2 2 S Insulated 1st Floor Metal .46 3 6 8 20 ft' WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V_/ __# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft' 6 ft 0 in 1 ft 0 in Drapes/blinds None NI 2 N 1 Vinyl Double(Clear) Yes 0.3 0.3 13.8 ft' 6 ft 0 in 1 ft 0 in Drapes/blinds None \\I 3 S 3 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft' 6 ft 0 in 1 ft 0 in Drapes/blinds None �t 4 N 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None • 5 N 5 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None N 6 S 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None N 7 S 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000152 543.2 29.82 56.08 .1446 3 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts N 1 Electric Heat Pump None HSPF:8.5 24 kBtu/hr 1 sys#1 COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts Nqk 1 Central Unit Split SEER: 15 24 kBtu/hr 720 cfm 0.75 1 sys#1 8/28/2017 10:58 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 3 of 4 1 I 1 FORM R405-2014 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation NNI 1 Electric None 1st Floor 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply--- --Return--- Air CFM 25 CFM25 HVAC# 1/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool V 1 1st Floor 6 165 ft2 1st Floor 196 ft2 Default Leakage . Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling 'X]Jan X Feb X Mar X Apr X May X Jun X Jul X Aug X Sep X Oct X Nov X Dec Venting X]Jan (Xd Feb f Xj Mar EXi Apr IN May IX1 Jun IN Jul IX]Aug Xj Sep [Xi Oct [Xi Nov [Xj Dec Venting X Jan X Feb X Mar X Apr Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 8/28/2017 10.58 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 4 i 1 I I ' FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index,the more efficient the home. 176 SANDY BEACH LANE, ATLANTIC BEACH , FL, 32233 1, New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Common R=19.0 1392.00 ft� b.Frame-Wood,Exterior R=19.0 528.00 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4 Number of Bedrooms 3 d.N/A R= ft2 5 Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 605.00 ft 6. Conditioned floor area(ft') 1358 b.N/A R= ft' 7 Windows" Description Area c.N/A R= ft's a. U-Factor. Dbl,U=0.30 105.06 ft' 11.Ducts R ft a.Sup:1st Floor,Ret: 1st Floor,AH:Attic 6 165 SHGC: SHGC=0.30 b U-Factor: N/A ft' SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor N/A ft' a.Central Unit 24.0 SEER:15.00 SHGC: d. U-Factor N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: Area Weighted Average Overhang Depth: 3.049 ft. a.Electric Heat Pump 24.0 HSPF:8.50 Area Weighted Average SHGC: 0.300 8 Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 605.00 ft' a.Electric Cap:40 gallons EF:0.92 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building :;.• 1HE sr,�"•••• Construction through the above energy saving features which will be installed(or exceeded) .•�4, �°�=._ in this home before final inspection. Otherwise, a new EPL Display Card will be completed • ' Vin`. based on installed Code compliant features. .'a_,, -• .^t's_�o' Builder Signature: Date: yJ 1t)//7 '•0 . — ; Address of New Home: (1 (o `` City/FL Zip:/ • •41, r .. .zz3� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/28/2017 10:58 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 i_____-----1 • FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 176 SANDY BEACH LANE Permit Number: ATLANTIC BEACH ,FL 32233 MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy Florida law [Section 553.9085.Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presotd and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4,4 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4,1.1 and R402.4 1 2 The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed, 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0 3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMANVDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors O R402.4-4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. IQ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553 993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"by either of the following 1 Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test.Total leakage shall be less than or equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w g (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1 The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2 Duct testing is not mandatory for buildings complying by Section R405 of this code. 8/28/2017 10:58 AM EnergyGauge®USA-v5.1 - Section R405.4.1 Compliant Software Page 1 of 3 FORM R405-2014 co In MANDATORY REQUIREMENTS - (Continue R403.2.3 Building Cavities(Mandatory). Building framing cavities shaThnot be used as ducts or plenums. R403.3 Mechanical system piping insulation(Mandatory). MechiEcal system piping capable of carrying fluids above 105°F(41`C) or below 55°F(13°C)shall be insulated to a minimum of R-3., N R403.3.1 Protection of piping insulation. l7 PP 9 R403.4.1 Circulating hot water systems(Mandatory). Circulating water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating purr) .when the system is not in use m r_ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipp421 with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps Mal consist of either a commercially available heat trap or a downward and upward bend of at least 3%,inches(89 mm)in the hot ver distribution line and cold water line located as close as possible to the storage tank Z 10 R403.4.4 Water heater efficiencies(Mandatory). -n O R403.4.4.1 Storage water heater temperature controls r w ▪ R403.4.4.1.1 Automatic controls. Service water he ng systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest adeeptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°I-t.38°C to 60°C). ▪ R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404 2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. ▪ R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1 Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2 Be installed at an orientation within 45 degrees of true south. R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies. based on building loads for the directional orientation of the building The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems- • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load.but not more than 1 15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 8/28/2017 10:58 AM EnergyGauger USA-v5.1 - -Section R405.4.1 Compliant Software Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1 Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2 When signed and sealed by a Florida-registered engineer, in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6 1 1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load ▪ R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas 2 A variable capacity system sized for optimum performance during base load periods is utilized. AZ0 R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403 (3j R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. Nti R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15 The energy requirements for portable spas shall be in accordance with ANSI/APSP-14 O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum • thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. ▪ R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4 0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems 3. Where pumps are powered exclusively from on-site renewable generation O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy source computed over an operating season. .t) RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights 111 R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6 O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space R-10 is allowed. 8/28/2017 10:58 AM EnergyGauge®USA-v5 1 - -Section R405.4.1 Compliant Software Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name. HABITAT-TRIPLEX-INSIDE176SB Builder Name BEACHES HABITAT Street 176 SANDY BEACH LANE Permit Office DUVAL COUNTY City,State,Zip ATLANTIC BEACH ,FL,32233 Permit Number Owner. Jurisdiction: 261300 Design Location FL.Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned J attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. �V Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. `v Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Bari insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available �v space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/28/2017 10.58 AM EnergyGauge®USA-v5 1 -Section R405 4.1 Compliant Software Page 1 of 1 i i Manual S Compliance Report Job: 176 SB Lane wrightsoft Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:W\MN.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Cooling Equipment Design Conditions Outdoor design DB: 92.8°F Sensible gain: 16874 Btuh Entering coil DB: 76.6°F Outdoor design WB: 77.0°F Latent gain: 3209 Btuh Entering coil WB: 63.5°F Indoor design DB: 75.0°F Total gain: 20083 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 800 cfm Sensible capacity: 18688 Btuh 111%of load Latent capacity: 3802 Btuh 118%of load Total capacity: 22490 Btuh 112%of load SHR: 83% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 22226 Btuh Entering coil DB: 68.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FX4DNF025L Actual airflow: 800 cfm Output capacity: 24000 Btuh 108%of load Capacity balance: 32 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 4.7 kW 73%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 2017-Oct-17 20:13:23 wrlghtsoft Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 M ...\Beaches Habitat\176 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE Pect SummaryJob: 176 SB Lane ro 4 wrightsoft Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Pante Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: Beaches Habitat Notes: 176 Sandy Beach Lane Desi• n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18522 Btuh Structure 14062 Btuh Ducts 3704 Btuh Ducts 2812 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22226 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 16874 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1992 Btuh Ducts 1216 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftp) 1358 1358 Equipment latent load 3209 Btuh Volume(1t3) 10624 10624 Air changes/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 20083 Btuh Equiv.AVF (cfm) 80 41 Req.total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A00300 Cond 25HBC524A00300 AHRI ref 9154698 Coil FX4DNF025L AHRI ref 9154698 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 16800 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 7200 Btuh Temperature rise 27 °F Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.84 Capacitybalance point=32°F Backup: Input=5 kW, Output= 16145 Btuh, 100 AFUE Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2017-Oct-17 20:13:23 g Right-Suite®Universal 2017 17.0.29 RSU09479 Page 1 ACOPik ..\Beaches Habitat\176 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE + wrightsoft Right-J® Worksheet Job: 176 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Pante Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Entire House Great 2 Exposed wall 230.0 ft 58.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 16.0 x 21.0 ft 5 Room area • 1328.0 ft' 336.0 ft' I I I I r Ty Construction U-value Or 1 HTM Area (ft') Load 1 Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) I (Btuh) or perimeter (ft) (Btuh) 1 Heat I Cool I Gross N/P/S 1 Heat I Cool I Gross WP/S Heat I Cool 6 W 12B-Osw 0.097 ne 3.64 2.70 280 280 1019 755 0 0 0 0 . W 12E-Osw 0.068 ne 2.55 1.43 384 384 979 551 168 168 428 241 12E-Osw 0.068 se 2.55 1.43 256 206 526 296 128 78 199 112 1D-c2ow 0.570 se 21.38 18.20 29 29 630 536 29 29 630 536 11 11D0 0.390 se 14.62 11.78 20 20 298 240 20 20 298 240 W 12B-Osw 0.097 sw 3.64 2.70 248 248 902 669 0 0 0 0 W 12E-0sw 0.068 sw 2.55 1.43 416 416 1061 597 168 168 428 241 )/ 12E-Osw 0.068 nw 2.55 1.43 256 220 561 316 0 0 0 0 �pO 1D-c2ow 0.570 nw 21.38 39.24 16 0 333 612 0 0 0 0 11D0 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0 C 16B-Oad 0.408 - 15.30 21.91 68 68 1040 1490 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 32 32 38 55 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 668 668 2806 4018 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 768 128 4747 0 336 58 2151 0 • • 1 6 1 c)AED excursion 11354 I15239102011I 17 Envelope loss/gain I 575 4135 12 a) Infiltration 3283 796 828 201 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 3 690 0 0 Appliances/other 2000 0 Subtotal(lines 6 to 13) 18522 14062 4963 1555 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 123 25 14 Subtotal 18522 14062 5086 1580 15 Duct loads 20% 20% 3704 2812 20% 20% 1017 316 Airtrequoired(cfm) I I 228001 168001 I I 6103 22001 1896 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ? wrightsoft Right-Suite®Universal 2017 17.0.29 RSU09479 2017-Oct-17 20:13:23 A- a \ Page 1 9...\Beaches Habitat\176 Sandy Beach Lane13581.rup Calc=MJ8 Front Door faces:SE +3+ wrightsoft Right-J® Worksheet Job: 176 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Ponte Vedra,FI 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Mech Kitchen 2 Exposed wall 6.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 4.0 x 6.0 ft 1 0 x 136.0 ft 5 Room area 24.0 fl' 136.0 fl' I I 1 I 1 I Ty Construction U-value OrI HTM I Area (ft ) Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) 1 Heat i Cool 1 Gross N/P/S Heat I Cool 1 Gross I N/P/S Heat I Cool 1 6 W 12B-Osw 0.097 i ne 3.64 2.70 i 0 0 0 0 01 0 0 0 . W 12E-Osw 0.068 ne 2.55 1.43; 0 0 0 0 80 80 204 115 12E-Osw 0.068, se 2.55 1.43 0 0 0 0 0: 00 0 1D-c2ow 0.570 se 21.38 18.20� 0 0 0 0 0: 0 0 0 1 1 11D0 0.390 se 14.62 11.78 0 0 0 0 0' 0 0 0 W 128-Osw 0.097 sw 3.64 2.70 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 48 48 122 69 32' 32 82 46 12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 0 1 1 DO 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-Oad 0.408 - 15.30 21.91 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 37.09 0.00 24 6 223 0 136 14 519 0 6 I c)AED excursion 1 I I -11 I I -23 It Envelope loss/gain 68 805 137 345 12 a) Infiltration 86 21 200 48 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal(lines 6 to 13) 431 89 1005 2186 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -431 -89 1078 613 14 Subtotal 0 0 2083 2799 15 Duct loads 20% 20% 0 0 20% 20% 417 560 Air req d(cfm) I 0I 00I I 2499 90 I 33591 159 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ---•' wrig htsoft Right-Suite®Universal 201717.0.29 RSU09479 2017-Oct-1720:13:23 Pa e2 '�' ...Teaches Habitat)176 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE g 4 wrightsoft Right-J® Worksheet Job: 176 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bath Bed 1 2 Exposed wall 8.0 ft 21.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.0 x 8.0 ft 12.0 x 9.0 ft 5 Room area 64.0 ft' 108.0 ft' I I t I I t Ty Construction U-value Or HTM Area (ft') Load 1 Area (ft') Load number (Bt uh/ft'-'F) 1 (Bt uh/ft') 1 or perimeter (ft) (Btuhl or perimeter (ft) (Btuh) Heat I Cool 1 Gross N/P/S Heat I Cool 1 Gross N/P/S Heat I Cool 6 W 12B-Osw 0.097 ne 3.64 2.70 0 0 0 0 0 0 0 0 . W 12E-Osw 0.068 ne 2.55 1.43 64 64 163 92 72 72 184 103 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 11 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12B-Osw 0.097 sw 3.64 2.70 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 0 0 0 0 12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 96 80 205 115 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 16 0 333 612 D 1 1 D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-Oad 0.408 - 15.30 21.91 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 32 32 38 55 0 0 0 0 C 166-7ad 0.112 - 4.20 6.01 0 0 0 0 108 108 454 650 F 22A-tpl 0.989 - 37.09 0.00 64 8 297 0 108 21 779 0 6 I c)AED excursion I I I -2 1 I I 329 I1 Envelope loss/gain It 498 145 1955 1809 12 a) Infiltration 114 28 300 73 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 612 173 2254 2112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 771 550 1252 894 14 Subtotal 1383 723 3507 3006 15 Duct loads 20% 20% 277 145 20% 20% 701 601 i Airtaeql ui d(cfm) I I I 1660 601 867 411 I I 41581 3601 171 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ÷ wrightsoft ft 2017 17.0.29 RSU09479 2017-Oct-17 20:13:23 .KT�R Page 3 ..\Beaches Habitat\176 Sandy Beach Lane\13581.nip Calc=MJ8 Front Door faces:SE 4 wrightsoft Right-J® Worksheet Job: 176 SB Lane Entire House Date: 10-17-2017 Florida Air Service & Engineering By: 13581 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web'.VVWW.NORTHFLORIDAAIR.COM 1 Room name Hall Bed 3 2 Exposed wall 21.0 ft 37.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1 0 x 100.0 ft 1.0 x 171.0 ft 5 Room area 100.0 ft' 171.0 ft' I I I I r Ty Construction U-value Or HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool 1 Gross 1 WP/S ( Heat 1 Cool 1 Gross 1 WP/S Heat I Cool 6 W 12B-Osw 0.097 ne 3.64 2.70 0 0 0 0 72 72 262 194 . W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 128 128 326 184 1D-clow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 11 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12B-Osw 0.097 sw 3.64 2.70 0 0 0 0 88 88 320 237 W 12E-Osw 0.068 sw 2.55 1.43 136 136 347 195 8 8 20 11 12E-Osw 0.068 nw 2.55 1.43 32 12 30 17 0 0 0 0 1D-clow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 D 11D0 0.390 nw 14.62 11.78 20 20 298 240 0 0 0 0 C 16B-Oad 0.408 - 15.30 21.91 68 68 1040 1490 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 0 0 0 0 171 171 718 1028 F 22A-tpl 0.989 - 37.09 0.00 100 21 779 0 0 0 0 0 ED excursion -21 -21 61 IEnvelope loss/gain I I 24941 19201 16471 1634 12 a) Infiltration 300 73 528 128 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 2794 1993 2175 1992 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -2794 -1993 334 317 14 Subtotal 0 0 2509 2309 15 Duct loads 20% 20% 0 0 20%. 20% 502 462 1 Fur requi ed(gym) 1 1 1 01 01 1 1 3011 081 27711 131 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right-Suite®Universal 2017 17 0.29 RSU09479 2017-Oct-17 20:13:23 Pa e4 � '� _.\Beaches Habitat\176 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE g 4 wrightsoft Right-J® Worksheet Job: 176 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Ponte Vedra,FI 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bath 2 Bed 2 2 Exposed wall 9.0 ft 38.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 16.0 x 11.0 ft 5 Room area 63.0 ft' 176.0 ft' r r I It r Ty Construction U-value Or 1 HTM Area (ft') Load 1 Area (ft') Load number (Btuh/ft'-'F (Btuh/fV) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) 1 Heat 1 Cool Gross N/P/S Heat I Cool I Gross I N/P/S j Heat I Cool 6 W 12B-Osw 0.097 ne 3.64 2.70 72 72 262 194 88 88 320 237 W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 0 0 0 0 1D-c2ow 0.570 se 21.38 18.20 0 0 0 0 0 0 0 0 11 11D0 0.390 se 14.62 11.78 0 0 0 0 0 0 0 0 W 12B-Osw 0.097 sw 3.64 2.70 0 0 0 0 64 64 233 173 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 24 24 61 34 Vel 12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 128 128 326 184 1D-c2ow 0.570 nw 21.38 39.24 0 0 0 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 0 0 0 0 C 16B-Oad 0.408• - 15.30 21.91 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 0 0 0 0 C 16B-7ad 0.112 - 4.20 6.01 63 63 265 379 176 176 739 1059 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 0 0 0 0 • 6 c)AED excursion 1 15271 5-61 { 16801 1-221 Envelope loss/gain 12 a) Infiltration 128 31 542 132 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 655 598 2222 2026 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 483 458 594 564 14 Subtotal 1138 1056 2816 2590 15 Duct loads 20% 20% 228 211 20% 20% 563 518 Airtaegoued(cdm) I I 1 13651 49 1267 601 I 33791 122 31481 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -+3+ wrightsoft 2017-Oct-17 20:13:23 -477,--. Right-Suite®Universal 2017 17.0.29 RSU09479At_ Page 5 `(`A _.\Beaches Habitat\176 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE 4 wrightsoft Right-J® Worksheet Job: 176 SB Lane Entire House Date: 10-17-2017 By: Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Loft 2 Exposed wall 18.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 1.0 x 150.0 ft 5 Room area 150.0 ft' i i I i i r Ty Construction U-value Or 1 HTM Area (ftW) Load ( Area Load number (Btuh/ft'-°F (Btuh/f(') or perimeter (ft) (Btuh) or perimeter 1 Heat I Cool 1 Gross i N/P/S Heat 1 Cool l Gross 1 WP/S 1 Heat I Cool 6 W 12B-Osw 0.097 ne 3.64 2.70 48 48 175 129 . W 12E-Osw 0.068 ne 2.55 1.43 0 0 0 0 12E-Osw 0.068 se 2.55 1.43 0 0 0 0 1D-clow 0.570 se 21.38 18.20 0 0 0 0 11 1100 0.390 se 14.62 11.78 0 0 0 0 W 12B-Osw 0.097 sw 3.64 2.70 96 96 349 259 W 12E-Osw 0.068 sw 2.55 1.43 0 0 0 0 12E-Osw 0.068 nw 2.55 1.43 0 0 0 0 1D-clow 0.570 nw 21.38 39.24 0 0 0 0 0 11D0 0.390 nw 14.62 11.78 0 0 0 0 C 16B-Oad 0.408 - 15.30 21.91 0 0 0 0 C 16B-30ad 0.032 - 1.20 1.72 0 0 0 0 C 16B-7ad 0.112 - 4.20 6,01 150 150 630 902 F 22A-tpl 0.989 - 37.09 0.00 0 0 0 0 61 c)AED excursion I I -14 Envelope loss/gain I} 1154 1276 1 I{ 12 a) Infiltration 257 62 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1411 1338 Less external load 0 0 Less transfer 0 0 Redistribution -1411 -1338 14 Subtotal 0 0 15 Duct loads 20% 20% 0 0 Too0 0 Air tal reqrouirmed(cfmload ) I I I 0I 0I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2017-Oct-17 2 :23 Right-Suite®Universal 2017 17.0.29 RSU09479 P3 Page 6 'K ...\Beaches Habitat\176 Sandy Beach Lane13581.rup Calc=MJ8 Front Door faces:SE 1st Floor Bed 1 171 cfm Hall 60 Pm r 6 " 4 " Sup Riser • 10 " 14 " Kit her ■ ■ 6 „ M 800 cfm 10 " owl! 159 cfm • 110cm 6 " Grea • 110 &m Job#: 176 SB Lane Florida Air Service & Engineering Scale: 1 : 71 Performed for: Page 1 Beaches Habitat 150 Hilden Road 308 Rig ht-Suite®Universe 120 17 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:13:43 WVNN.NORTHFLORIDAAIR.COM ..t\176 Sandy Beach Lane\1358I rup birc 2nd Floor Bed 2 6 " Sup Ri 147 cfm d 21'12 x 10 4 " oft 6 " 6Baffi 12 x 10 131 cfm B[xi 1 _ Job #: 176 SB Lane Florida Air Service & Engineering Scale: 1 : 71 Performed for: Page 2 Beaches Habitat 150 Hilden Road 308 Rig ht-Suite®Universal 2017 Ponte Vedra,Fl 32081 17.0.29 RSU09479 Phone:904-823-9696 2017-Oct-17 20:13:43 WVNN.NORTHFLORIDAAIR.COM _t\176 Sandy Beach Lane\13581.rup Duct System Summary Job: 176 SB Lane wrightsoft Date: 10-17-2017 Entire House By: Florida Air Service & Engineering Plan: 13581 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Beaches Habitat Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply/return available pressure 0.125/0.125 in H2O 0.125/0.125 in H2O Lowest friction rate 0.100 in/100ft 0.100 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 130 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath h 1660 60 41 0.100 4.0 Ox 0 VIFx 16.0 90.0 st2 Bath 2 c 1267 49 60 0.100 4.0 Ox 0 VIFx 16.2 110.0 st1 Bed 1 c 3607 151 171 0.100 6.0 Ox 0 VIFx 22.0 90.0 st2 Bed 2 c 3108 122 147 0.100 6.0 Ox 0 VIFx 9.1 110.0 st1 Bed 3 c 2771 108 131 0.100 6.0 Ox 0 VIFx 20.4 110.0 st1 Great h 3052 110 45 0.100 6.0 Ox 0 VIFx 14.9 90.0 st2 Great-A h 3052 110 45 0.100 6.0 Ox 0 VIFx 26.4 90.0 st2 Kitchen c 3359 90 159 0.100 6.0 Ox 0 VIFx 8.8 90.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 279 339 0.100 621 10.0 0 x 0 VinIFIx st2 Peak AVF 521 461 0.100 487 14.0 0 x 0 ViniFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 800 800 0 0.080 573 16.0 Ox 0 VIFx Bold/italic values have been manually overridden 2017-Oct-17 20:13:24 t wrightsoft Right-Suite®U niversal 2017 17 0.29 RSU09479 Page 1 AC-Z4, .113eaches Habitat1176 Sandy Beach Lane\13581.rup Calc=MJ8 Front Door faces:SE