201 MAGNOLIA ST - ROOF • CITY OF ATLANTIC BEACH _ s� 800 SEMINOLE ROAD • ATLANTIC BEACH, FL 32233 "! ;3 INSPECTION PHONE LINE 247-5814 ROOF NON SHINGLE - MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROOF17-0053 Description: METAL ROOF Estimated Value: 23460 Issue Date: 12/29/2017 Expiration Date: 6/27/2018 PROPERTY ADDRESS: Address: 201 MAGNOLIA ST RE Number: 170548 0000 PROPERTY OWNER: Name: WEEKS RYAN THOMAS Address: 2117 WILLESTON DR W JACKSONVILLE, FL 32246 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: THE ROOF DUCK WATERTIGHT ROOFING SYSTEMS Address: 6095 Shadehill RD JACKSONVILLE, FL 32258 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. Jr City of Atlantic Beach APPLICATION NUMBER ,41 _ sA Building Department (To be assigned by the Building Department.) 800 Seminole Road ¶COP 17 - 0053 Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904) 247-5845 E-mail: building-dept@coab.us Date routed: I Z/( 17 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 0 l A Si- Department review required Yes No Applicant: ( (AG- Rocc rming &Zoning Tree Administrator Project: AL R0 OF- Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [pproved. nDenied. [Not applicable (Circle one.) Comments: BUILDTNG PLANNING &ZONING Reviewed by: Date: /2'77•(9U/7 TREE ADMIN. Second Review: nApproved as revised. ❑Denied. nNot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application OFFICE COPY /r ' ' City of Atlantic Beach 800 Seminole Road,Atlantic Beach,FL 32233 ` `'1� Phone:(904)247-5826 Fax:(904)247-5845 Job Address: 201 Magnolia Street Permit Number: R\Lac i` `7-DC 5 3 Legal Description 10-16 16-25-29E SALTAIR SEC 3 LOT 513 RE# 17123-00321 Valuation of Work(Replacement Cost)$ 23,460 Heated/Cooled SF 2277 Non-Heated/Cooled 948 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • if an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New Metal Re-Roof Florida Product Approval# FL#11651.9 R2 and FL18686-R1 (See Form) for multiple products use product approval form Property Owner Information Name: Ryan Weeks Address: 201 Magnolia Street City Atlantic Beach State Florida Zip 32233 Phone 904-982-8948 E-Mail litercola@hotmail.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Owner Contractor Information Name of Company: The Roof Duck Watertight Roofing Systems Qualifying Agent: Gregory Alan Ross,Jr. Address 3948 3rd Street South,Unit 195 City Jacksonville Beach State Florida Zip 32250 Office Phone 904-345-0663 Job Site/Contact Number 904-345-0663 State Certification/Registration# CCC1330963 E-Mail alan@theroofduck.com Architect Name&Phone# N/A Engineer's Name&Phone# N/A Workers Compensation FRSA Self Insurers Fund--Policy#870-040118--Expires 1/1/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTIC OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS Ts , - - •ROPER . IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER 'AN ATTORNEY :EFORE BE RDING YOUR NOTICE OF COMMENCEMENT. i V __.v (Signature of Owner or Agent including Contractor) Or (Signature of Contractor) nSig nd sworn to(or affirm-d)before�m�e/this fZ day of Signed and sworn to(or affirmed before me this itay of gee'/Aha , 2011' ,by kid /) (4Z> `� C. O\") ,by A , 0. • i:'ature of Notary) (Signs of otary) /s2/j Vj / _.-I. Plasonatl1.Knawn fie— — I j Personally Known OR roduced Identific tion { )Produced Identification ````P{IY PV6� JON.J WHISMAN C .� ;�.. USStl�IoN NIPoDU09 ,����',,,, pe of ide ti i is - n: Type of u Identification:Identification tion: f +P���;`,,,, _'.'�:A Notary nPtiti gtalr ul Fluntta �IOZ'gl noN sa�ldx3'WuwO Ayy ,p� � � .; ' Commission #GG 054696 =N' rii r: OL E6 jj I uolsslwwo3 =• `�` ''Fo�`d;°•` My Comm.Expires Feb 9,2021 w , ephol j to°leis-311Qnd A1eloN ?; ti _ _ _ Oct1 t II����,,,,�, _ TT r � ANIJtlB 1 tl00H11 ���,��''" Doc # 2017287983, OR BK 18222 Page 1192 , Number Pages : 1 , Recorded 12/16/2017 09 :55 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10 . 00 PermJ v QOO Fl 7-0 0S-7 NOTICE OF COMMENCEMENT OFFICE COPY State of Florida Tax Folio No. 17123-00321 County of Duval To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 10-16 16-2S-29E SALTAIR SEC 3 LOT 513 Address of property being improved: 201 Magnolia Street Atlantic Beach Florida 32233 General description of improvements: _ New Metal Rc-Rouf Owner: Ryan Weeks Address: 201 Magnolia Street Atlantic Beach Florida 32233 Owner's interest in site of the improvement: Owner Fee Simple Titleholder(if other than owner): N/A MUM: Contractor: The Roof Duck Watertight Roofing Systems Address: 3948 3rd Street South,Unit 195 Jacksonville Florida 3225 Telephone No.: 904-345-0663 Fax No: Surety(if any) N/A Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: N/A Address: Phone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: N/A Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: N/A Address: Telephone No: _ Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNE Signed: / Date: (2-- (Z- t Before me th • I a day of 7)a de:0 b4,e- in the County of Duval,State Of Florida,has personally appeared Xff/jAN lniCa/E' Notary Public at Large,State of Florida,Cdunty of Duval. My commission expires:Fag, t, 2 0 2 Personally Known: or Ft' .�"�Ar ager ifs.' �•�= JONI J.WHISMAN •if • NotaryPublic•Slate of Florida e4 ' ` Commission#GG 054696 1 ?o.i~��`'�r My Comm. Expires Feb.,,,,,..• D 9 2021 litirii\ _ . FLORIDA PRODUCT APPROVAL G6ifCst illt, SUPPLY & MANUFACTURING 4111, - ;; LOKTM 24 GA. GULFLOK"' 16" WIDE ROOF PANEL OVER 15/32" PLYWOOD Product Evaluation Report OFFICE COPY GULF COAST SUPPLY & MANUFACTURING, LLC. Lu C.) �. 24 Ga. GulfLokTM 16" Wide Roof Panel over 15/32" Plywood d z z N a0 < o N Florida Product Approval #11651.9 R2 E tai a � w ° o Florida Building Code 2014 0 moo ii Per Rule 61G20-3 w H < o ° Method: 1 -DO Q v a mQ � z Category: Roofing O i,. 2 W Subcategory: Metal Roofing LLA 0 a La m Compliance Method: 61G20-3.005(1)(d) w > -° NON HVHZ w fa V N ¢ w WLi 5 Product Manufacturer: m ct Gulf Coast Supply & Manufacturing, LLC. ►0,11.1 , 14429 SW 2nd Place, Suite G30 , op:... . .••00 tal ., li • Newberry, FL 32669 / ' S .1'' :.*: No. 75519 Engineer Evaluator: : * . Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 :0 •, STATE of :�: '",,—NAL ENG' : Validator: "''.... '``% Locke Bowden, P.E. #49704 0.6130/2,015 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL#11651.9 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT J KUHN ENGINEERING, LLC 11670 ISLAND LAKES LANE. BOLA RATON, FL 33498 • FL COA L`30464 FLORIDA PRODUCT APPROVAL GulfCoast 4:I SUPPLY & MANUFACTURING Litimmisoo, LOKT 24 GA. GULFLOKF 16" WIDE ROOF PANEL OVER 15/32" PLYWOOD Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: GulfLokTM, 7/8" Nailstrip Roof Panel, Minimum 24 Ga. Steel, Maximum 16" Coverage, Roof panel restrained with fasteners into minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 24 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.0235" Minimum Width: 16" Coverage Maximum Female Rib: '/8" Tall Male Rib: 3/4" Tall Rib with Slotted Strip Panel Seam: Snap Lock Panel Clip: 24 Ga. Zinc Aluminum Coated Steel, 24" Long. Used at Corner Zones only, where required design pressures exceed-121.75 psf. Panel Fastener: Through Panel Slot: (1)#10-12x1" Pancake Type A 1/4" Minimum Penetration through Plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table "A" Maximum Design Pressures Roof Areas Assembly A Assembly B Assembly C Assembly D Maximum Design Pressures 81.75 psf 96.75 psf -121.75 psf -161 psf Fastener Spacing 10 3/4" O.C. 5W O.0 5W O.0 5'W'O.0 Sealant No No Yes No Panel Clip No No No Yes *Design Pressure includes a Safety Factor=2.0. FL#11651.9 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT { ''-- 7---'--• - �::=_--„—..,.—m...._-r_ 11670 ISLAND LAKES LANE. BOCA RATON. FL 33498 • FL COA 30464 FLORIDA PRODUCT APPROVAL GulfCoast SUPPLY & MANUFACTURING 0� 'IJNLOKTM 24 GA. GULFLOK''' 16" WIDE ROOF PANEL OVER 15/32" PLYWOOD Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization#TST-5328) Report No. 117-0089T-05 Dated 06/2005 2. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0301T-10A-C, Dated 07/26/2013 3. TAS 125 Architectural Testing, Inc. (FBC Organization #TST-1527) Report No. B9000.01-450-18, Dated 12/12/2012 4. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519)@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. FL#11651.9 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT KUHN ENGINEERING, LI,C t670 ISLAND LAKES LANE, BOCA RATON, FL 33498 • FL COA#30464 /NAIIVE` . FLORIDA PRODUCT APPROVAL Gulf Coast ;UFV;.Y & MANUFACTURING ja_4i, , 1, Lo TM LI _ Ng W 24 GA. GULFLOK`" 16" WID ,00F PAN OV -: 15/ - •"-'LYWOOD ..PRI -- :, N • 1 " _ .9R '-- Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.9 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT J KUHN ENGINEERING, LLC ! ISLAN ) LAKES LANE, F30CA RATON, FL 3349S • FL WA.==3046.1 / ',it\ ENGINEER'S LOAD TABLE SPEC GulfCoast SUPPLY , MANUFACTURING • TM LOK 24 GA. GULFL ' !'.4 16" WID , ; • • PA OV_•• . 15/ _ YWOOD �- O' --- -...'-PPROV• - N •: ' 1 1.9 R ENGINEER LOAD TABLE: 24 Ga. GulfLokTM 16" Wide Roof Panel over 15/32" Plywood Buildings having a Roof Mean Height 20'-0"; Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category Il, Enclosed Building, based on Florida Building Code 2014. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE - SPEED (MIN.1/4" (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING CDX ZONE 1 (1)#10-12x1" PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ZONE 2 (1)#10-12x1" PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A CDX ZONE 3 (1)#10-12x1" PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY B ASSEMBLY B ASSEMBLY C 1.) PANEL DESCRIPTION: GULFLOKTM, MIN. 24 GA, 7/8" RIB, 16" MAXIMUM COVERAGE, SNAP SEAM. 2.)PANEL FASTENER: (1)#10-12X1" PANCAKE TYPE A, 1/4" MIN. PENETRATION THROUGH PLYWOOD. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:81.75 PSF AT 101/4" O.C.ASSEMBLY A,96.75 PSF AT 51/4"O.C.ASSEMBLY B, -121.75 PSF AT 51/8"O.C.WITH SEALANT ASSEMBLY C,-161 PSF AT 5'/8"O.C.WITH CLIP ASSEMBLY D. PRESSURE BASED ON UL 580/UL 1897 TESTING BY FORCE ENGINEERING &TESTING. 4.)PLYWOOD DECKING: MIN. 15/32" THICK, APA RATED PLYWOOD, GRADE C-D. MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 -ZONE 2 HIP ROOF ?, Note:Dimension(a)is defined as 10%of the minimum width of the building or ZONE 3 -_ 'a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be ' less than either 4%of the minimum width of the building or 3 feet. RIDGE ASSEMBLY A/B 16"COVERAGE r ZONE 1 (1)#10-12 X 1'TYPE A PANCAKE EAVE SPACING:SEE UPLIFT TABLE ZONE 2 GABLE ROOF a ASSEMBLY C 1/4..-5/16-DIAMETER BEAD OF TITEBOND SEALANT --RIDGE (1)#10-12 X 1'TYPE A PANCAKE— SPACING:SEE UPLIFT TABLE ASSEMBLY D W/CLIP ZONE 1 — GuNLok"CLIP 24 GA. VV ZONE 3 EAVE (1)#10-12 X1"TYPE A PANCAKE— • SPACING:SEE UPLIFT TABLE FL#11651.9 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT FoKUHN ENGINEERING, LLC 11670 ISLAND LAKES LANE, BOLA I<%vl UN, I L 34'1• • FL (_U.A a-;ti4b 1 Florida Building Code Online Page 1 of 2 OFFICE COPY S q C .. I' �; 7, . 1lyl+'_� roman, mercers oNlr®trasroxs armor• BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search d '('''1' r t Product Approval `i : USER.Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL18686-R1 • Application Type Editorial Change Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived 0 Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany,NI 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Michael Stieh mstieh@gaf.com Technical Representative Beth McSorley Address/Phone/Email 1361 Alps Road Wayne,NJ 07470 (800)365-7353 bmcsorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Miami-Dade BCCO-EVL Quality Assurance Entity Miami-Dade BCCO-CER Quality Assurance Contract Expiration Date 02/21/2018 Validated By Miami-Dade BCCO-VAL Certificate of Independence Referenced Standard and Year(of Standard) Standard Year ASTM D226 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option C http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqulGtg5bCXRsc... 1/19/2017 Florida Building Code Online Page 2 of 2 Date Submitted 10/30/2015 Date Validated 10/30/2015 Date Pending FBC Approval Date Approved 11/03/2015 Summary of Products FL# Model,Number or Name Description 18686.1 FeltBuster High-Traction Synthetic Roofing Felt Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL18686 R1 II NOA 14-0915.02.odf Approved for use outside HVHZ:Yes Verified By: Miami-Dade BCCO-EVL Impact Resistant:No Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL18686 R1 AE NOA 14-0915.02.pdf Contact US::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Caovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.°Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click hem. Product'_ lApproval Accepts: "�^ I® IC MCk11 11��..��CredIt Lard Safe utt http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquIGtg5bCXRsc... 1/19/2017 MIAMIDE COUNTY MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsipanny,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Leak Barriers and Roof Deck Protection LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-1104.11 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0915.02 MIAMI.DADE COUNTY Expiration Date: 02/21/18 APPROVED Approval Date: 09/10/15 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Categorv: Underlayment Material: SBS/Polypropylene/Asphalt PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description WeatherWatch® 36"x 50' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced, Mineral Surfaced Leak 36"x 66.7' rolls bituminous sheet material for use as a leak barrier Barrier underlayment in sloped roof assemblies. Manufacturing Designed as an ice&rain shield. Location#2,3 WeatherWatch®XT 36"x 50' rolls ASTM D 1970 Mat surfaced modified, fiberglass reinforced Mat Surfaced Leak 36"x 66.7' rolls bituminous sheet material for use as a leak barrier Barrier underlayment in sloped roof assemblies. Manufacturing Designed as an ice&rain shield. Location#3 StormGuard®Film 36"x 66.7' rolls ASTM D 1970 Modified,fiberglass reinforced,bituminous sheet Surfaced Leak Barrier material for use as a high temperature leak barrier Manufacturing underlayment in sloped roof assemblies. Location#2 Designed as an ice&rain shield. LibertyTM SBS Self- 39)/g"x 66'rolls ASTM D 1970 Self-adhering SBS roof membrane. Adhering Base/Ply Sheet Manufacturing Location#2 UnderRoo(IM 2 393/8"x 67.8' rolls ASTM D 1970 Self-adhering reinforced membrane of SBS Polyester-Surfaced modified asphalt with polyester surfacing for use Leak Barrier with asphalt shingle roof assemblies. Roof slopes Manufacturing of 2:12—12:12 are acceptable as indicated by Location#1,3 local codes and manufacturer's installation instructions. UnderRoo1 M HT High 39)/8"x 61.0' rolls ASTM D 1970 Self-adhering reinforced membrane of SBS Temperature Leak modified asphalt with polyester surfacing for use Barrier as a high temperature underlayment in sloped Manufacturing metal and asphalt shingle roof assemblies. Roof Location#3 slopes of 2:12— 12:12 are acceptable as indicated by local codes and manufacturer's installation instructions. NOA No.: 14-0915.02 MIAMFWCOUNTY Expiration Date: 02/21/18 APPROVED Approval Date: 09/10/15 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Deck-ArmorTM 54"x 222' rolls ASTM D 226 A UV-stabilized polypropylene breathable Premium Breathable 48"x 100' rolls "Ivpe 11 underlayment. To be used for roof deck Roof Deck Protection protection as an underlayment in sloped roof Manufacturing assemblies. Location#4 Tiger PawTM Roof Deck 48"x 250'rolls ASTM D 226 A UV-stabilized polypropylene non-breathable Protection 48"x 100'rolls Type II underlayment. To be used for roof deck protection Manufacturing as an underlayment in sloped roof assemblies. Location#5,8,9 FeltBuster®High- 48"x 250' rolls ASTM D 226 A UV-stabilized polypropylene non-breathable Traction Synthetic Type I underlayment. To be used for roof deck protection Roofing Felt as an underlayment in sloped roof assemblies. Manufacturing Location#10 Shingle-Mate®Roof 36"x 144' rolls ASTM D 226 Fibergass-reinforced asphalt felt underlayment.To Deck Protection Type I be used for roof deck protection as an Manufacturing underlayment in sloped roof assemblies. Location#6,7 NOA No.: 14-0915.02 MIAMIDADE COUNTY Expiration Date: 02/21/18 APPROVED Approval Date: 09/10/15 Page 3 of 8 MANUFACTURING LOCATION: 1. Fresno,CA 2. Mt.Vernon,IN 3. North Branch,NJ 4. North Bay,Ontario 5. Mission,British Columbia 6. Pryor,OK 7. McGregor,TX 8. Qingdao,China 9. Charleston, SC 10. Spartanburg, SC EVIDENCE SUBMITTED: Test Azencv Test Identifier Test Name/Report Date Intertek Testing Services NA Ltd. 3077464-01 ASTM D 1970 08/23/06 3090131 Wind Uplift and Self Sealability 08/23/06 100258583C0Q-010A ASTM D 226 Type H 01/11/11 100673818COQ-003 ASTM D 226 Type H 06/13/13 10157289000Q-005 ASTM D 226 Type H 04/17/14 PRI Construction Materials RGM-023-02-01 ASTM D 4798 05/16/07 Technologies,LLC. GAF-112-02-01 ASTM D 226 Type II 03/15/06 GAF-238-02-01 ASTM D 1970 03/03/10 GAF-323-02-01 ASTM D 1970 11/30/11 GAF-324-02-01 ASTM D 1970 11/30/11 GAF-325-02-01 ASTM D 1970 11/30/11 GAF-326-02-01 ASTM D 1970 11/30/11 GAF-275-02-01 ASTM D 1970 11/11/10 GAF-344-02-01 ASTM D 1970 04/23/12 GAF-339-02-01 ASTM D 226 Type I 03/14/12 ELK-311-02-01 ASTM D 1970 09/11/07 GAF-446-02-01 ASTM D 226 Type I 09/26/13 GAF-518-02-01 ASTM D 226 Type I 06/04/14 NOA No.: 14-0915.02 MIAMIDADECOUNTY Expiration Date: 02/21/18 APPROVED Approval Date: 09/10/15 Page 4 of 8 APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies of ASTM D 226 Type II,Deck-Armor"Premium Breathable Roof Deck Protection,FeltBuster® High-Traction Synthetic Roofing Felt,or Tiger Paw"Roof Deck Protection with a minimum 4" side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's installation instructions).Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch®XT Mat Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier,or LibertyTM SBS Self- Adhering Base/Ply Sheet membrane with a minimum 3"side lap and 6"end lap. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch®XT Mat Surfaced Leak Barrier, or StormGuard®Film Surfaced Leak Barrier is acceptable. Surfacing: Approved Roofing Assembly. Deck Type 1: Wood,non-insulated Deck Description: 19/32' or greater plywood or wood plank System E(2): Membrane mechanically fastened to deck. Separator Sheet: One or more plies of GAF GAFGLAS®Ply 4,GAFGLAS®Flex-P1yTM 6,Rosin Paper,ASTM D 226 Type I or Type H, Shingle-Mate®Roof Deck Protection,Deck-Armor'Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt,or Tiger Paw'Roof Deck Protection loose laid. Membrane: One or more plies of WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch®XT Mat Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier,or LibertyTM SBS Self- Adhering Base/Ply Sheet membrane mechanically fastened with a minimum 3"side lap and a 6" end lap to deck through the separator sheet with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. in the field of the roll. Surfacing: Approved Roofing Assembly. NOA No.: 14-0915.02 MIAM A. �E p= Expiration Date: 02/21/18 Approval Date: 09/10/15 Page 5 of 8 Deck Type 1: Wood,non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck,membrane adhered. Secondary Water Install a minimum 4"wide WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch®XT Barrier: Mat Surfaced Leak Barrier,or StormGuard®Film Surfaced Leak Barrier membrane over the (Optional) joints of the plywood roof deck prior to installation of the base sheet.Do not overlap end or side joints.All side and end laps should be butted firmly side by side,flush with each other but not overlapped.Do not leave the WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch® XT Mat Surfaced Leak Barrier,or StormGuard®Film Surfaced Leak Barrier membrane exposed for more than 30 days without a roof deck protection underlayment protecting the secondary water barrier. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies of ASTM D 226 Type II,Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt,or Tiger PawTM Roof Deck Protection with a minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape manufacturer's installation instructions). Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fasteners. Surfacing: Approved Roofing Assembly. Deck Type 1: Wood,non-insulated Deck Description: 19/32"or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck,membrane adhered. Base Sheet: Two plies of ASTM D 226 Type I or Shingle-Mate®Roof Deck Protection OR one or more plies of ASTM D 226 Type II,Deck-Armor'Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt,or Tiger Paw"Roof Deck Protection with a minimum 4"side lap and a 6"end lap mechanically fastened to the deck with approved nails and tin caps 6"o.c. at the laps and four staggered rows 12"o.c. in the field of the roll. If roof is exposed to rain/snow,tape all end and side laps with approved butyl adhesive based seam/cover tape or an approved waterproof cloth duct tape(follow the tape's manufacturer's installation instructions).Always apply tape over all fasteners at the center of the roll or the end laps to help prevent rain or snow from entering at the fastneners. Membrane: One or more plies of StormGuard®Film Surfaced Leak Barrier,UnderRoof17"2 Polyester- Surfaced Leak Barrier or UnderRoofl M HT High Temperature Leak Barrier membrane with a minimum 4"side lap and 6"end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Surfacing: Approved for Metal roofing(StormGuard®Film Surfaced Leak Barrier,or UnderRoofr"HT High Temperature Leak Barrier), Slate, and Asphalt Shingle assemblies. NOA No.: 14-0915.02 MIAMI.DADE COUNTY Expiration Date: 02/21/18 APPROVED Approval Date: 09/10/15 Page 6 of 8 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck-Armor" Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger Paw"Roof Deck Protection shall not be used as roof tile underlayment. 3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. WeatherWatch®Mineral Surfaced Leak Barrier,WeatherWatch®XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofrM 2 Polyester-Surfaced Leak Barrier, UnderRoof" HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck-Armor" Premium Breathable Roof Deck Protection, FeltBuster® High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall be installed in strict compliance with applicable Building Code. 4. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoof" 2 Polyester-Surfaced Leak Barrier, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- ArmorTM Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofmg Felt, and Tiger PawTM Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities. 5. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofrM 2 Polyester-Surfaced Leak Barrier, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- ArmorTM Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection membranes shall not be applied over an existing roof membrane. 6. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoof" 2 Polyester-Surfaced Leak Barrier, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- Armor"Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. 7. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoofr" 2 Polyester-Surfaced Leak Barrier, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- Armor"Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofmg Felt, and Tiger PawTM Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoof" 2 Polyester-Surfaced Leak Barrier, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate® Roof Deck Protection, Deck- ArmorTM Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt, and Tiger PawTM Roof Deck Protection as a component part of an assembly in the Notice of Acceptance. If WeatherWatch® Mineral Surfaced Leak Barrier,WeatherWatch®XT Mat Surfaced Leak Barrier, StormGuard®Film Surfaced Leak Barrier, LibertyTM SBS Self-Adhering Base/Ply Sheet, UnderRoof m 2 Polyester-Surfaced Leak Barrier, UnderRoofrM HT High Temperature Leak Barrier, Shingle-Mate®Roof Deck Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster®High-Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck Protection are not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail NOA No.: 14-0915.02 MIAMFDADE COUNTY Expiration Date: 02/21/18 APPROVED Approval Date: 09/10/15 Page 7 of 8 LIMITATIONS: compatibility of the products,wind uplift resistance,and fire testing results. 8. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45° F and rising. 9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 10. Roll or broom the entire membrane surface so as to have 100% contact with the surface,giving special attention to overlap areas. 11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 12. Wherever the adhesive back of UnderRoofr"t 2 Polyester-Surfaced Leak Barrier, or UnderRoofr"' HT High Temperature Leak Barrier comes in contact with polyester surfacing such as end laps, penetrations, and flashing material,it must be set in a 1/8"troweling of an approved ASTM D 4586 Type I roofing cement. 13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MANMADE COUNTY APPROVED END OF THIS ACCEPTANCE NOA No.: 14-0915.02 MIAMI-DADE COUNTY Expiration Date: 02/21/18 APPROVED Approval Date: 09/10/15 Page 8 of 8