Loading...
1380 Camelia St ROW permit ts CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RIGHT OF WAY - SINGLE OR TWO FAMILY RIGHT OF WAY MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ROW18-0001 Description: install 45-ft. wood pole Estimated Value: 0 Issue Date: 1/10/2018 Expiration Date: 4/10/2018 PROPERTY ADDRESS: Address: 1380 CAMELIA ST RE Number: 171050 0210 PROPERTY OWNER: Name: PATRICK GLEBER INC Address: 888 KINGMAN RD HOMESTEAD, FL 33035 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: JACKSONVILLE ELECTRIC AUTHORITY Address: 21 CHURCH ST W 3RD FLR JACKSONVILLE, FL 32202 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. City of Atlantic Beach APPLICATION NUMBER Js yt�� Building Department (To be assigned by the Building Department.) 800 Seminole Road Q' G r� Atlantic Beach, Florida 32233-5445 0 ' C)C) Phone(904)247-5826 • Fax(904)247-5845 J11 �,l E-mail: building-dept@coab.us "' Date routed: 1 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: C QMQ_Ut C� Sf Department review required Yes No I t� Building Applicant: Planning &Zoning Tree Administrator Project: i Publi—c Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed byDate: TREE ADMIN. Second Review: [-]Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach APPLICATION NUMBER \Js Building Department (To be assigned by the Building Department.) 800 Seminole Road Q F Atlantic Beach, Florida 32233-5445 r tl ' C)Q Phone (904)247-5826 • Fax(904)247-5845 x _ E-mail: building-dept@coab.us a: Date routed: 1 Vy� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: (Y\ Department review required Yes No —( r Building Applicant: Planning &Zoning 1 ; Tree Administrator Project: tj 0 'Do P[rk511C Ut'—ilities� Public Safety Fire Services Review fee $ P—/_ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLJCATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING / PLANNING &ZONING Reviewed by: Date: l TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PU ORK Comments: UBLIC UTILITI PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 CITY OF ATLANTIC BEACH JAN - 4 2018 CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS 800 Seminole Road 904-247-5800 Atlantic Beach,Florida 32233-5445 Fax 904-247.5845 PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION. Date I/ 6 0PERMIT# v— 'u" O O 1 Job Address- 1394) //(_.1 'q f ISSUED BY THE CITY Permitee: J-r:�A Telephone# �� 7 � 1 Permittee Address: Requesting Permission to Construct:�h) �s L/,Ss weed Location: (Reference to Cross-Street) 1. Applicant declares that prior to fling this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate Locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority . Yes( ) No ( ) Date: Bell South Telephone Company Yes O No ( ) Date: Ferrell Gas Yes( ) No ( ) Date: Comcast Yes( ) No ( ) Date: 2. Whenever necessary for the construction, repair, improvement; maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach Jar Fpfl?n*da Department of Transportation Standards and be performed under the supervision of 1AJ..S� (Contractor's Project Superintendent)located at 7,,i '.V__i t.✓ ` .. _ 11,, Telephone M 61,f^ 77s3 4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. 6. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the city Right of Way are to be included with this application. 7. This permittee shall commence actual construction in good faith with 616, days, If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8. It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the'land to be entered upon and used by the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again immediately upon completion. OWNER Signed: Date: Before me this day of In the County of Duval, State Of Florida,has personally appeared Notary Public at Large,State of Florida,County of Duval. My commission expires: Personally Known: Produced Identification: ENGINEERING DESIGN ORACLE PERMIT MAXIMO [GATE REL PRCUECT#.31971 Iy0.: UM73 V\O#. 30217156 0(:01/05/18 all TREE TRI IVM NG SUB-STA- NEPTUNE BEACH N.O.: 561 REQ'D:NO C B-L ENGNEER Robert Sirlmm N.O.: NIA ZIP CODE NSA C LJSTOMERI SVC PHONE LOC -11OR 1382 CANEIJA STJ POLE INSTALL 561 CENTER SSSC N.O.:665-7793 STA 1, P# 1382 CAMELIA ST./ INSTALL 4513W I N600 AND 25KVA. MOVE PAP TO STA 2. STA 2, P#1347 SAMELIA ST. I *****THIS IS FOR A NEW HOME AT 1380 I 0 I 00 25A I I o •`r � o I I i I o ♦ N o I 1430 j j 25A I I �♦ � I J I Q -- I 14TH ST W A ABC_-_ ' _ STA 1 Q o o< [0 V o Ln —I Q o 'o I G-0 STA 2 '� o i T 2T , ♦ I- 720 �rn♦ o PVOX I ♦ I 750 138 ' j 25A I z d-N � /0 ♦ - M I- I F- o cr1 F- M �N MM O I M � 1--I � ♦ , c`1M♦ 1350 ' I o . ♦ M I 50A ' � ♦M ,M+c� N � I • lM♦ ' -101. CUE Reports Estimate Number:31971 1382 CAMELIA ST./45/3W POLE Estimate Type:SR Contractor:HEN KELS&MCCOY INC INSTALL. Estimate Version: By: SIMPRB MWO#/Task:30217156 Required Date: Oracle Project#:8004473 Estimated On: 01/04/2018 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales lax) $1,387.76 $1,387.76 2.Transformer Cost(wl sales tax) $1,028.37 $1,028.37 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $467.23 $832.93 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $326.17 $127.02 7.Engineering Costs(Variable%of line 4) $130.59 $232.80 8.Project Equipment Costs(40%of total equipment costs) $275.52 $0.00 9.Material Handling(8.30%of lines 1 &2) $200.54 $200.54 10.Inspection(6.84%of line 4) $0.00 $56.97 11.Total Cost of Project $3,816.19 $3,866.40 12.Work Order Estimate(Line 11 minus line 8,9,&10) $3,340.13 $3,665.86 13.Billable Equipment Depreciation(60%of total equipment costs) $413.28 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11 +13+(58.71%of 4&7)) $4,580.45 $4,003.08 15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $3,552.08 $2,974.71 Time Estimate Crew Hours Total Manhours 3.75 14.99 ----------------------------------------------------------------------------------------------------------------------------------- -ISI- CUE Reports Estimate Number:31971 1382 CAMELIA ST./45/3W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL. Estimate Version: By: SIMPRB MWO#/Task:30217156 Required Date: Oracle Project#:8004473 Estimated On: 01/04/2018 CU Detail Build Transfer Remain In Place Remove DA F-5 1 DA1 F-5*2 1 DGAC 1 DGAC*25 1 DHLC 1 DHLC*2 1 G1W 1 G1W*2 1 P.45/3W 1 RUBUP 2 S4 1 S4*1/0 4 S9 1 S9*1/0 1 RUBDOWN 2 J&A. CUE Reports Estimate Number:31971 1382 CAMELIA ST./45/3W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL. Estimate Version: By: SIMPRB MWO#/Task:30217156 Required Date: Oracle Project#:8004473 Estimated On: 01/04/2018 Material Summary Item Quantity Item Number Item Description 2 ARRL1003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER POLE(MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL VOLTAGE 2 BKTAC009 BRACKET, ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM MATERIAL OVER ROD TYPE: SINGLE PHASE 2 BKTFS001 BRACKET, FIBERGLASS STANDOFF, 2" FIBERGLASS ROD, 18" STANDOFF TO INS BASE ROD COVERED WITH RAYCHEM HEAT- SHRINK MATERIAL, DUCTILE IRON FITTINGS 2 SOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV. WITH 4 SQUARE NUTS ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 BOLMS020 BOLT, MACHINE, 5/8"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 50 EACH) 7 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 CLAHL001 CLAMP, HOT LINE, 6-1/0-MAIN, 6-1/0-TAP 4 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 5000#,4-3/0 ALUM 2 CLATGO01 CLAMP, TRANSFORMER TANK GROUND, "BRONZE"6 SOL- 1 STR. 3 CNNCP002 CONNECTOR,#2, 6-2 MAIN, 2-1/0 TAP, ALUMINUM COMPRESSION, PARALLEL TAP, 2 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 4 CNNGR002 COUPLING, GROUND ROD, "THREADLESS" REMARKS: FOR THREADLESS GROUND RODS 3 CNNTS009 CONNECTOR, CONTAMINATED ENVIRONMENT,TRANSFORMER SECONDARY SET SCREW TYPE WITH INHIBITOR, 1/2" STUD, RANGE: 12-350, 6-PORTS. 6 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 46 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON PLASTIC REEL, 4"X 11.5"W/2" HOLE 140 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD& COPPERWELD- COPPER .204" DIAMETER 1480# BREAKING STRENGTH (50#COIL- 427' ) 8 COVIC002 COVER, "D" DIE, INSULATING, 2-1/2" 2 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE TO GROUND 100A 27 KV 170 KV BIL (54 EA PER PALLET) 1 FUSOH022 FUSE, OVERHEAD DISTRIBUTION, 1.6 AMP, TRANSFORMER 2 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 5 INSS0002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 2 INSVP001 INSULATOR, VERTICAL POST,TIE TOP 35-KV, 3/4" STUD TAP STANDARD PACKAGING IS NOT TO EXCEED THREE UNITS OR 72 POUNDS. -AS*A, CUE Reports Estimate Number:31971 1382 CAMELIA ST./45/3W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL. Estimate Version: By: SIMPRB MWO#/Task:30217156 Required Date: Oracle Project#:8004473 Estimated On: 01/04/2018 4 NUTSL003 NUT, LOCK, SQUARE, 5/8"HOLE SIZE, HOT DIPPED GALVANIZED 4 NUTSL004 NUT, LOCK, SQUARE, 3/4" BOLT SIZE, HOT DIPPED GALVANIZED 1 POLW0006 POLE, WOOD, 45'CLASS 3 (T/L=26), WEIGHT=1,770 LBS 6 RODGRO03 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED ONLY! 1 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL SPLICING 1 STIC0001 STIRRUP, COMPRESSION, 2-1/0,ALUMINUM BODIES, COPPER BAIL, BAIL SIZE-2-SOL 2 STUL1001 STUD, LINE POST, DIA. SHANK-3/4", SHANK LENGTH- 1-3/4", GALVANIZED STEEL W/NUTS AND WASHERS; 3/4" HEAD SIZE 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5" HIGH X 2" WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 1 TIEPRO01 TIE, PREFORMED LINE,#2 AAAC, 23"MIN. LENGTH, "F" NECK, SIDE TIE .316"-.357"COND. RANGE 1 TRAC0001 TRANSFORMER, 25 KVA, 14760125565Y VOLT PRIMARY, 120/240 VOLT SECONDARY, SINGLE PHASE, CONTAMINATED ENVIRONMENT 4 WASRD004 WASHER, ROUND, 5/8" BOLT SIZE X 1 3/4" DIAMETER, GALVANIZED, 650 EA P/BOX) 17 WASRD005 WASHER, ROUND, 3/4" BOLT SIZE X 2"DIAMETER, GALVANIZED, 500 EACH PER BOX"' 9 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 5/8"X 3/4" BOLT SIZE, GALVANIZED 5 WASSP002 WASHER, SPRING, 314"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) J&I. CUE Reports Estimate Number:31971 1382 CAMELIA ST./45/3W POLE Estimate Type:SR Contractor:HENKELS&MCCOY INC INSTALL. Estimate Version: By: SIMPRB MWO#/Task:30217156 Required Date: Oracle Project#:8004473 Estimated On: 01/04/2018 CU Summary CU Name Quantity Description DA1 F-5*2 1 2 TANGENT TO 10 DEGREE ANGLE-UNSHIELDED, CONTAMINATED DGAC*25 1 TRANS; CI, 26AKV 120/240 25KVA DHLC*2 1 #2 AL. HOT-LINE CLAMP G1W*2 1 WOOD POLE-EQUIPMENT GROUND P.45/3W 1 45 FT. CLASS 3 WOOD POLE RUBUP 2 LINE RUBBER INSTALLATION, PER SECT. S4*1/0 4 SECONDARY DEADEND S9*1/0 1 SECONDARY SPLICE CU Name — QuantityDe5cri to ion RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT. i + `° WEST 14TH ST P/!H A-920 ^ 3 MH:;V9 1397 FM xy .c r� Hr �w i i I. HX ...0 _. b U k4 n ,x j i� 130'3 6 goo