Loading...
2025 BEACH AVE - REVISION 1-3-18 ' x CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST /CORRECTIONS TO PLAN REVIEW COMMENTS Date f / Revision to Issued Permit_ Corrections to Comments Permit# R Esa 7 b z 4 S Address 2 G Z S i�-2cz.c... Project A }- yr Contractor/Contact Name 3 F l � c" s?" Email Phone �� Ct— g 3^�/ l G Permit Fee Due$ ,��•OCA Description of Proposed Revision/Corrections: Perm / a t 414- to v� ! UCS ryl dk /eS C d�'1✓j'� Additional Increase in Building Value $ t? opt Additional S.F. B signing below,T e�""�� �tl• -e affirm the Revision is inclusive of the proposed changes. Y (printed name) Signa re of Contras r/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved__X Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: yy� �lding R ewed By Planning &Zoning Tree Administrator Public Works !� Y 7 ad Public Utilities Date Public Safety Fire Services • „�` y`e�plt�9:elt�er�a�..si:}f�fl DESIGN SPECIFICATIONS a0 DESIGN CODE: a i 2014 FLORIDA BUILDING CODE — EXISTING BUILDING ' �V ALTERATION LEVEL 11 G 0 E A D 0 E ORIGINAL PLANS, of, UNLESS PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE. W •+ #'� • >. .. ®+ OF DESIGN LOADS: ACTUAL AND UNIFORM ROOF FLOOR ROOF LOADING (cd=1.25) (cd-1:00) TOP CHORD LIVE LOAD' 20 psf 40 psf TOP CHORD DEAD LOAD 7 psf (ARCH SHINGLES) 10 psf iishpMiu "�y BOTTOM CHORD LIVE LOAD 10 psf 0 psf LU15 A f Orltlg0 PE BOTTOM CHORD DEAD LOAD 5 psf 5 psf DEFLECTION CRITERIA: yy ROOF FRAMING: LIVE LOAD L/240 TOTAL LOAD L/180 DEI. ( 21 2017 FLOOR FRAMING: LIVE LOAD L/360 & TOTAL LOAD L/240 WIND LOADING ASCE 7-10 FL PE NO 5331 BASIC WIND SPEED (ASCE 7-10) ——————— 130 MPH IMPORTANCE FACTOR ——-————. -— 1:00 MEAN ROOF HEIGHT — —————————— 25.0 FT /// /�� ■■ ROOF PITCH ——— ———— —— EXISTING { BUILDING CATEGORY —— = 'SIV ————————— II p�j /Gn —rj EXPOSURE CATEGORY ——— — _—_ D ENCLOSURE CLASSIFICATION ———— ——— ENCLOSED Bi INTERNAL PRESSURE COEFFICIENT ———— — f .18 D ATE f '__Y__-j1 , COMPONENTS & CLADDING SIGNE6 ALLOWABLE DESIGN PRESSURES TRIBUTARY INTERIOR EDGE STRIP (PSF): AREA (sf) ZONE (PSF) .a. 4,-6,, 10 +30.2 —32.9 +30.2 —40.5 50 +27.1 —29:6 +27:1 —34.2 100 +25.7 —28.2 +25.7 =31:2 THE VALUES ABOVE ARE ALLOWABLE WIND PRESSURE VALUES (ASD): THE ABOVE WIND PRESSURES HAVE BEEN REDUCE BY 0.60 AS PERMITTED BY THE ALLOWABLE STRESS'DESIGN METHODOLOGY. NO FURTHER REDUCTION SHALL BE PERMITTED • COMPONENT &CLADDING WALL ELEMENTS SHALL BE DESIGNED FOR BOTH POSITIVEANDNEGATIVE PRESSURES SHOWN IN TABLE ABOVE. • LINEAR INTERPOLATIONIS PERMISSIBLE. • PLUS = PRESSURE AND MINUS = SUCTION. - • DESIGN OF WINDOWS/DOORS FASTENING TO THE WALL:FRAMING IS THE RESPONSIBILITY OF THE WINDOW/DOOR MANUF./SUPPLIER & SHALL MEET THE ABOVE NOTED POSITIVE AND NEGATIVE PRESSURES_ SCOPE OF SERVICE MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE FOR ANY OF THEMTOCONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. LIMITS OF STRUCTURAL ENGINEERING DESIGN RESPONSIBILITIES THE ITEMS'SPECIFICALLY DESIGNED BY THE STRUCTURAL ENGINEER ARE LIMITED TO HEADERS AND BEAMS DIRECTLY SUPPORTING ROOF, FLOOR AND CEILING FRAMING SHOWN ON PLAN.ITEMS NOT DESIGNED INCLUDE WATER/WEATHERPROOFING, PRE—ENGINEERED_WOOD FLOOR AND ROOF TRUSSES, FLOOR FRAMING NOT SPECIFICALLY INDICATED, TRUSS—TO-TRUSS CONNECTIONS, ARCHITECTURAL EMBELLISHMENTS NOT SPECIFICALLY INDICATED (EYEBROWS, CORNICE, CORNICE RETURNS, PROJECTIONS, ETC) AND ANY OTHER ARCHITECTURAL, MECHANICAL OR ELECTRICAL SYSTEM. Lou i' ontigo and PROJECT 2025 BEACH AVENUE Associates , Inc . BUILDER BUILDING DYNAMICS, INC. 420 Osceola Avenue JOB NO. SHT.NO. Ion )ax. Beach.Florida 32250 BUIL-17-01204 Ph.242-0908 Fax.241-9557 S �, FL:CA#8344 SC:CA#3579 DATE 12.21.17 FASTEN EXISTINGNEW ±2' 3" .Aw»Hliiil� # OPENING ���,,` ��rh�' SYP 2 FLOOR JOISTS T A., 1-JACK - BEAM w/ LUS2 'r -- •\�" ��AAoyy •��'•• HANGER (TYP.) -�, i - F'•. s �-• STUD. - _--_ O L Luis A Pantigo PE •t0 ¢ . U _... J ( * ; 53311 Z - - > I=I C II� --------------- V)DEC 15 2017 �' i * C/) J - - NEW (2)2x8 SYP#2 ------- HEADER w 1 -JACK ATeo ER PER _. o Q AND 1 -KING STUD. F�PE NO 53311 ;y�� F•�,.`Q, r F .0. EXISTING FLOOR ^NII �� A REVISE,. 'y J'j� ,..,..• ����� Z �' w JOISTS ABOVE TO N I;II FASTEN EXISTING ��� ��/g �/ ] Z REMAIN AS IS. _ ____ I- FLOOR JOISTS TO U Q blFr BEAM w/ LUS26 _ - _ _ I� a_ h HANGER (TYP.) �U Z __ -- ---- - - - -- n _ - — a_ _ _ )2x4 SYP#2 --- z �J1 II� NEW (4 _ POST. FASTEN TO STRAP POST �n --� L III _- TO BELOW N "' W W _-_ POST, SEE FOUNDATION w/ DTT2Z PLAN. - -- z (n w/ 2-CS16. p N - Q USING /2„b THREADEDco --_ - - EXISTING FLOOR SHEATHING LOTOR c~j o W ROD EPDXIED 6 MIN.' JOIST TO REMAIN. REMAIN AS IS. = Z cu - FASTEN EXISTING TO BEAM 1 11}- CONTRACTOR VERIFY NEW POST m o 1 w/ HUS26-2 HANGER. - o SK 1 C �[ I SITS OVER MIN. 12" DEEP - I CONCRETE FOUNDATION. CONTACT - - ... . . -- EXISTING WALL - -- f - - - FRAMING TO EXISTING FLOOR EOR IF OTHER CONDITIONS EXIST; I —. :: ra. --- REMAIN. JOIST TO REMAIN. NEW 4x4 SYP 2 POST BELOW SIMPSON DTT2Z FASTEN -- :_ POST ABOVE. FASTEN TO w/ %2" THREADED ROD w/ H 5 USING iN"� FOUNDATION TT _--- EPDXIED 4" MIN 0R !I THREADED ROD EPDXIED 8" M v 2X6 TITEN HD - EXISTING NEW NEW EXISTING - - _- NEW 2'-6"x_ 6"x12 cC ti ... I STRAP HEADER PER .._• o ,'�; - - DETAIL 2/S2. SEE TAIL SK_ Poaiv SEE O N DEEP FOUNDATION ------------------ - -- - DE 1/ 1 � FASTEN POST > b N U - I _:^ _ ._-- NEW (2)2x12 SYP#2 -__ -:: _- -� To FOUNDATION •^ Q ° v EXISTING HEADER TO BE PER PLAN. ,..• +-, oHEADER w/ 1 -JACK REMOVED. CONTRACTOR EXISTING 4" CONCRETE LOCATION To ° � . Z _- - - AND 2-KING STUDS, t SLAB ON GRADE. CUT SLAB. .� .0 o M r 00 +l z 9I� __ -_= I N G. p V p o --- -- w -- 1t ---- -- --_ - P R OIV D N 0 N L�jD X B E A v o o w o i SPF#2 POST BELOW - _ O N --- -- _ z - - a � : . , Q EXISTING FLOOR BEAM. EXISTING STEM a wAL I- -... — ----------- _"j_ — - - - L v i C3" CONTRACTOR TO DRILL 4" AND EPDXY EXISTING FOOTING. i }. - _ ' 3-#4x16" HORIZONTAL VERIFY MIN, 8 DEEP DOWEL (TYP.). SIMPSON DTT2Z FASTEN CONCRETE F0 TLNG --- 2 DRILL 4" AND EPDXY w /2" THREADED ROD EA: END OF EADER. �: 3-#5X24" HORIZONTAL EPDXIED 4" MIN 0R DOWEL (TYP. . _.: - _ _ ._ %2x6" TITEN HD. NEW FOOTING INTERSECTION w/ EXISTING --- ----- _....... STEMWALL AND SLAB PARTIAL FRAMING P LAN F 1 OOTING REPAIR SCALE:3/16"= F-0" sK 1