Loading...
479 Irex roof repair CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 5M 9' INSPECTION PHONE LINE 247-5814 RESIDENTIAL - ALTERATION RESIDENTIAL MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0053 Description: roof repair Estimated Value: 42685 Issue Date: 2/13/2018 Expiration Date: 8/12/2018 PROPERTY ADDRESS: Address: 479 IREX RD RE Number: 1714070000 PROPERTY OWNER: Name: SCHAFFHALISER EDWARD G Address: 479 IREX RD ATLANTIC BEACH, FL 32233-3903 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: STYLES CONSTRUCTION, INC. Address: 1537 PENMAN RD SUITE A QA DARRELL GLEN SMITH JACKSONVILLE BEACH, FL 32250 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. _% VJ:r;- City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road z Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904) 247-5845 Date routed: E-mail: building-dept@coab.us City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Ll_T Uff I Y_ ment review required Yes -No Property Address: Building' --7 Applicant: L't 0 --planning & zoning Tree Administrator Project: f 0 0 Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [dApproved. []Denied. ENot applicable (Circle one.) Comments: =BU I L!D I 5N ) PLANNING &ZONING Reviewed by: Date:-2- 6 -c� V TREE ADMIN. Second Review: DApproved as revised. OlDenied. [:]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. DDenied. [:]Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 -LA & �G_ OFFICE COPLIding Permit Application Updated 12/8/17' J City of Atlantic Beach JAN 3 1 2018 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 Job Address: 21P Permit Number: CIO U eLij 2fi LOT I U t��K 10 Legal Description 3H(" E 'Rip ap; �T 'pi� I pa I. RE# i 00p(�� Valuation of Work(Replacement Cost)$Lq�O%S Heated/Cooled S1 15J -2 Non-Heated/Cooled • Class of Work(Circle one): New Addition Alteration<�Ri Move Demo Pool Window/Door • Use of existi n g/pro posed structure(s)(Circle one): Commercial (�R��s_identiaL,' • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes (ED) N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Qu 0_� R!��L Florida Product Approval# for multiple products use product approval form PropertV Owner Information �ikName: Address: sz n city- HLAZ f::kc State E I , zip �3 3 -� Phone E-Mail Owner or Agent(if Agent,Power of Attorney or Agency Letter Required) Contractor Information Name of Company: jr��, J-AC� _Qualifying Agent: f),4Q9_f 6- &n Address J53] - lo r., City J, mr,, )e� _JA)�, E& , State Zip Office Phone J-910-1 Site/Contact Number SV -'I 10--1 State Certificatior/Registration# E-Mail :0 P,;;�_i�jF_ LL_ !A 1731 A 1�je Architect Name&Phone# Engineer's Name&Phone# Workers Compensation ALAC) A,A Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS, FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc.NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 00f 4 44Z 9--2: ---1 (Signaf4e.of Owner or Agent) (Sign5ture of Contractor) (including contractor) 1)before rnathis day of Signed and sworn to(or affirmed)before me thiJ0 day of "N lez by commissiw I(ju UuOu"', E tee MY 5,2020 Ao'v xpi (Silz 'I (Signature Notary) (Signature of Notary) Personally Known OR Personally Known OR X ."I B SALCAN ��Pproclucecl Identification Produced Identification 4, Notary Public-State of Florida r­­iquiri 9 Er M545 Type of Identification: Type of Identification: my com rr,Ex o i res May 11,2019] NOTICE OF COMMENCEMENTM'9 C 6.6 P V (PREPARE IN DUPLICATE) Permit No. Tax Folio No. 171407-0000 OFFICE COPY State of FL County of DUVAL To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes, the following information is stated in this NOTICE OF COMMENCEMENT. Legal description of property being improved: 31-16 17-2S-29E R/P OF PT OF ROYAL PALMS UNIT 2A LOT 16 BLK 10 Address of property being improved: 479 1 REX ROAD ATL.BCH. FL. 32233 General description of improvements: ROOF REPAIR Owner EDWARD G. SCHAFFHAUSER Address 479 IREX ROAD ATL. BCH. FL. 32233 Owner's interest in site of the improvement OWNER Fee Simple Titleholder (if other than owner) N/A Name Address ntractor DARRELL G. SMITH (STYLES CONSTRUCTION INC.) Address 1537-A PENMAN ROAD JAX. BCH. FL. 32250 Phone No. 904-545-9107 Fax No. Surety(if any) N/A Address Amount of bond $ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name N/A Address Phone No. Fax No. Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served.- Name N/A Address Phone No. Fax No. In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06 (2)(b), Florida Statutes. (Fill in at Owner's option). Name N/A Address Phone No. Fax No. OFFICE COPY Ridgway Roof Truss Company (Trusses and Prefabricated Building Components) CAIO Mailing: RO. Box 1309—Gainesville, Florida 32602 b Physical: 235 SW 11 th Place—Gainesville, Florida 32601 LLI C) 0 Telephone: (352) 376-4436 Email:Sales@ RidgwayTruss.(:�'rm (n :C -i Z FAX:(352) 371-3316 www.RidgwayTruss.com j 40 z — C't 0 t Lu — m W 0 mt z C.) 00 U 00 a Uj P < a WARNING 93 ZMZ 0 04 0 5 U. 'n = 4L- Z 0 -S Uj U. U- 2 0 W 0. = M THESE TRUSSES MUST BEW � Ujs a � a W a W W W HANDLED AND ERECTED ACCORDING TO BCS1 SUMMARY SHEETS http://www.sbcindustry.docs/06—bcsi—booklet—final.pdf SEE TABLE OF CONTENTS SEALED DESIGN MANUAL PROJECT NAME: Irex Lane JOB NUMBER: 18-0006 CONTRACTOR: STYLES CONSTRUCTION, INC. DATE:- 1-19-18 az Ir REVISIONS: 6) COMMENTS: Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. MiTek RE: 180006- ROOF DESIGN INFO MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: STYLES CONSTRUCTION, INC. Project Name: Irex Lane Model: Tampa, FL 33610-4115 Lot/Block: Subdivision: - Address: City: Jacksonville State: FL Name Address and License#of Structural Engineer of Record, If there is one, for the building. Name: License#: Address: City: State: General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017 Design Program: OnLine Plus 30.0.069 Wind Code: ASCE 7-10 [All Heighll Wind Speed: 130 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 1 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G1 5-31.003, section 5 of the Florida Board of Professional Engineers Rules. No.—Seat# �Truss Name I Date 1 T1 3000813 1 R3 11/18/18 of IFLo c0i N�-- 2 C.) The truss drawing(s)referenced above have been prepared by MiTek USA,Inc. under my direct supervision based on the parameters E N provided by Ridgway Roof Trusses. No 39 8 Truss Design Engineer's Name: Albani, Thomas My license renewal date for the state of Florida is February 28,2019. -,0*. Z; -ir -33 –ft *41J Z IMPORTANT NOTE:The seal on these truss component designs is a certification STA OF that the engineer named is licensed in the jurisdiction(s)identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters 0 R \'O..-* N C51 shown(e.g.,loads,supports,dimensions,shapes and design codes),which were 0* 0***. .; q/ ******* vl� % given to MiTek. Any project specific information included is for MiTek's customers 1110 N A file reference purpose only,and was not taken into account in the preparation of these designs. MlTek has not independently verified the applicability of the design Thoffn A.Nbad PE No.31KIN parameters or the designs for any particular building. Before use,the building designer Mrrsk Usk Inc.R.Con SW should verity applicability of design parameters and properly incorporate these designs 6904 Peft East BW.Tarnpa R.33610 into the overall building design per ANSI1TPI 1,Chapter 2. Daft: January 18,2018 Albani,Thomas I of I Table of Contents 1.General Notes 2.WTCA 1-1995 ( Standard Responsibilities in the Design Process involving Metal Plate Connected Wood Trusses) 3.Engineering (insert) 4.Layout of Truss Placement Plan (insert) 5. Jobsite Package w/ BCSI B- 1, B-2, B-3 and B-4( Handling, Installing and Bracing Information) http://www.sbcindustry.com/docs/06-bcsi- booklet-finaLpff 6.Standard Chord and Web Repairs 7.Examples of Permanent Web Bracing Wood Truss Council of America NON YNY EIR Standard Responsibilities in the Design Process Involving Metal Plate Connected Wood Trusses WTCA 1 -1995 Developed by the WTCA Engineening Review Committee in cooperation with the Truss Plate Institute 2 2.0 OWNER RESPONSIBILITIES 2.1 Directly or through its representatives,which may include Truss Design Drawing and Truss Placement Plan; and the Contractor and/or Building Designer;(a)review and (d)coordinate the return of each approved Truss Design approve each Truss Design Drawing; (b) review and Drawing and Truss Placement Plan to the Truss approve theTruss Placement Plan;(c)resolve and approve Manufacturer prior to truss manufacturing. all design issues arising out of the preparation of each 3.0 BUILDING DESIGNER RESPONSIBILITIES 3.1 Design a structure suitable to ensure that the intended 3.2.8 Proper transfer of design loads affecting the function of eachTruss is not affected by adverse influences Truss;and including, but not limited to, moisture, temperature, 3.2.9 Adequate connections between Truss and non- corrosive chemicals and gases; Truss components, except as noted in Section 3.2 Prepare the Construction Design Documents,showing all 6.2.9. trussed areas, which must provide as a minimum the 3-3 Review and approve the Truss Placement Plan and each following: Truss Design Drawing for conformance with the 3.2.1 All truss orientations and locations; requirements and intent of the Construction Design 3.2.2 Information to fully determine all truss profiles-, Documents,the effect of eachTruss Design Drawing and Truss Placement Plan on othCTparts of the structure,and 3.2.3 Adequate support of the Truss and all truss the effect of the structure on each Truss. bearing conditions; 3.4 Specify permanent lateral bracing where indicated by the 3.2.4 Permanent bracing design for the structure Truss Designer on theTruss Design Drawings,to prevent including the Trusses,except as provided in 3.4 buckling of the individual truss members due to design and 6.2.12. loads. The Building Designer shall specify how the 3.2.5 Ile location,direction and magnitude of all dead permanent lateral bracing is to be anchored or restrained and live loads applicable to eachTruss including, to prevent lateral movement if all truss members, so but not limited to, loads attributable to- roof, braced,buckle together. This shall be accomplished by: floor,partition,mechanical,fire sprinkler,attic, (a)anchorage to solid end walls;(b)permanent diagonal storage,wind,snow drift and seismic; bracing in the plane of the web members; or (c) other means when demonstrated by the Building Designer to 3.2.6 All Truss anchorage designs required to resist provide equivalent bracing. uplift,gravity,and lateral loads; . 3.2.7 Allowable vertical and horizontal deflection criteria; 4.0 CONTRACTOR RESPONSIBILITIES 4.1 Provide to the Truss Manufacturer the Construction 4.4 Provide the approved Truss Design Drawings,approved Design Documents and all revisions and supplements Truss Placement Plans,and any supplemental information thereto. provided by the Truss Manufacturer to the individual or 4.2 Review and approve the Truss Placement Plan and each organization responsible for the installation of theTrusses. Truss Design Drawing for conformance with the 4.5 Comply with the field storage, handling, installation, requirements and intent of the Construction Design permanent bracing, anchorage, connections and field Documents, and the effect of the Truss Placement Plan assembly requirements of the Construction Design and each Truss Design Drawing on other trades involved Documents. in the construction of the structure and the effect of the other trades on the Trusses. 4.6 Determine and install the temporary bracing for the structure,including the Trusses. 4.3 Coordinate the review,approval and return of each Truss Design Drawing and the Truss Placement Plan by the Owner and Building Designer. 4 Quan Type Span Pl-H1 Left OH Right OH Engine-ing Job Mark Ti-_g�,­A 180006 R3 4 TR 231000 2.075 1- 6- 0 1- 6- 0 T13"M13 Irex �ane HO 3-4 HO 3-4 TC 11-6-01 6-10-8 1 11-11-0 1 16-11-8 1 23-10-0 11-6-01 5X5 B 2x4l 2x4 o� F 2-7-7 2.07S c7:--- �4-8= C 4x8 4x8 2-4-0 A C 81 D 4.5 4z6 4X5 W:308 W:308 R: 883 R: S72 U: 100 U: 99 BC EF-6-11 15-3-5 LZA 23-10-0 ALL PLATES ARE MT2020 Scale*0.246*=V MiTekV Online Plus- APPROX. TRUSS WEIGHT: 118.3 LBS Online Plus Version 30.0.069 -------------Webs------------- Directional. RUN DATE: 18-JAN-18 F -E 0.09 474 C Wind Speed: 130 mph E -B 0.31 836 T Risk Category II Southern Pine lumber design B -D 0.33 886 T Mean Roof Height: 14-0 values are those effective D -G 0,10 495 C Exposure Category: B 06-01-13 by SPIB//A.LSC UON Building Type: Enclosed CSI -Size- ----Lumber---- CT Defl -0.67" in E -D L/418 Zone location: Exterior TC 0.71 2x 4 SP-#2 LL Defl -0.35" in E -D L/792 TC Dead Load 4.0 psf BC 0.84 2x 4 SP-#1 Shear // Grain in G -C 0.23 BC Dead Load 6.0 psf WB 0.33 2x 4 SP-#3 Max comp. force 3676 Lbs Plates for each ply each face. Max tens. force 3630 Lbs Brace truss as follows: Plate - MT20 20 Ga, Gross Axea Connector Plate Fabrication O.C. From To Plate - MT2H 20 Ga, Gross Area Tolerance = 20% TC Cont- 0- 0- 0 23-10- 0 Plate - MS18 18 Ga, Gross Area This truss is designed for a or 24.0" 0- 0- 0 23-10- 0 it Type Plt Size X Y isi creep factor of 2.0 which BC Cont. 0- 0- 0 23-10- 0 A MT20 4.Ox 8.0 6.6 2.0 0.95 is used to calculate or 120.0" 0- 0- 0 23-10- 0 F MT20 2.Ox 4.0 Ctr Ctr 0.26 Vert(CT) deflection per B MT20 5.Ox 5.0 Ctr Ctr 0.79 ANSI/TPI 1. psf-Ld Dead Live G MT20 2.Ox 4.0 Ctr Ctr 0.26 TC 7.0 20.0 C MT20 4.Ox 8.0-6.6 2.0 0.97 BC 10.0 0.0 E MT20 4.Ox 5.0 Ctr Ctr 0.40 TC+BC 17.0 20.0 Sl MT20 4.Ox 6.0 Ctr 0.2 0.69 Total 37.0 Spacing 24.0" D MT20 4.Ox 5.0 Ctr Ctr 0.42 Lumber Duration Factor 1.25 Plate Duration Factor 1.25 REVIEWED BY: Fb Fc Ft Emin MiTek USA, Inc. TC 1.15 1.10 1.10 1.10 6904 Parke East Blvd. BC 1.10 1.10 1.10 1.10 Tampa, FL 33610 Total Load Reactions (Lbs) REFER TO ONLINE PLUS GENERAL it Down Uplift Horiz- NOTES AND SYMBOLS SHEET FOR * 883 100 U ADDITIONAL SPECIFICATIONS. * 872 99 U NOTES: it Brg Size Required Trusses Manufactured by: A 3.511 1.711 RIDGWAY ROOF TRUSS C 3.511 1.711 Analysis Conforms To: FEC2017 Plus 15 Wind Load Case(s) TPI 2014 Plus 1 LL Load Case(s) OH Loading Plus 1 DL Load Case(s) Soffit psf 2.0 This truss has been designed Membr CSI P Lbs Axl-CSI-Bnd for 20.0 psf LL on the B.C. ----------Top Chords---------- in areas where a rectangle Printed copies of this document are * -F 0.62 3616 C 0.15 0.47 3- 6- 0 tall by not considered signed and sealed and * -B 0.46 3209 C 0.16 0.30 2- 0- 0 wide the signature must be verified on * -G 0.38 3254 C 0.16 0.22 will fit between the B.C. any electronic copies * -C 0.71 3676 C 0.16 0.55 and any other member. --------Bottom Chords--------- Design checked for 10 psf non- A -E 0.78 3569 T 0.49 0.29 concurrent LL on BC. E -Sl 0.41 2426 T 0.33 0.08 Wind Loads - ANSI / ASCE 7-10 Sl-D 0.43 2426 T 0.33 0.10 Truss is designed as a Main D -C 0.84 3630 T 0.50 0.34 Wind-Force Resistance System ON- Cp)�gM 47�"�1996-2017 V-30�O 069 E�gk­irg-P�M*U1812018 3:27:14 PM P.Q.I IJOBSITE PACKAGE I IMPORTANT DOCUMENTS ENCLOSED PLEASE REVIEW AThe handling, storing, installing, restraining and diagonal bracing of structural building com- ponents requires specialized training, clearly implemented procedures, and careful planning and communication among the contractor, crane operator and installation crew. Handling and installing components without appropriate training, planning and communication greatly increases the probability of an accident resulting in property damage, serious personal injury and/or death. Prior to component installation,the documents should be examined and disseminated to all appropriate personnel,in addition to proper training and a clear understanding of the installation plan, any applicable fall protection requirements, and the intended restraint and bracing requirements.Trusses over 60 feet in length are very dangerous to install and may require com- plex temporary and permanent bracing. Please consult a Registered Design Professional. Examine the building,the building's structural framing system,bearing locations and related installation conditions.Begin compo- nent installation only after any unsatisfactory conditions have been corrected. Do not cut, modify or repair components. Report any damage before installation. The enclosed documents are offered as minimum guidelines only. Nothing contained in this jobsite package should be construed in any manner as expanding the scope of responsibility of, or imposing any additional liabilities on, the component manufac- turer. A DV EE R TE 14""I A' v El manejo, almacenamiento, instalaci6n, restricci6n y arriostre diagonal cle componentes; estructurales cle construcci6n requieren entrenamiento especializada, procedimientos; claramente implementaclos y planificaron y comunicaci6n clara entre el contratista, operaclor cle gr6a, y los obreros de instalaci6n. El manejar e instalar los componentes sin entrenamiento suficiente, planificaci6n y comunicaci6n adecuaclas aumenta la probabiliclad cle un accidente que resulta en clareo a propiedad, hericla seria o muerte. Antes cle la instalaci6n cle componentes, los documentos adjuntos deben ser examinaclos;y difundidos a todo el personal apro- piado, adem6s del entrenamiento pertinente y un claro entenclimiento del plan cle instalaci6n, cle todo requisito aplicable de la protecci6n contra la caida y cle los; requisitos previstos cle arriostre y restricci6n. La instalaci6n de trusses mis de 60 pies de largo es;muy peligrosa. Consulte a un Profesional de Diseflo Registrado. Examine la estructura, el sistema armaz6n estructural cle edificio, ubicaciones cle soporte e [as concliciones de instalaci6n cor- responclientes y comenzar con la instalaci6n de los componentes s6lo despu6s cle haber corregiclo toda conclici6n insatisfactoria. No corte, modifique ni repare los componentes y informe cualquier dai5o clescubierto antes de proceder a la instalaci6n. Los clocumentos adjuntos se ofrecen solamente como directrices minimas. Nada de lo incluido en este paquete debe interp- retarse cle manera que exceda el alcance de la responsabiliclad del fabricante cle componentes, ni en forma tal que imponga responsabilidades adicionales sobre 6ste. To view a non-printing PDF of this document, visit www.sbcindustry.com/�obsitees. --FOR DESIGN RESPONSIBILITIES SEE REVERSE BCSIal8l SUMMARY SHEET GUIDE FOR HANDLING INSTALLING RESTRAINING AND BRACING OF TRUSSES SPANS.OVa.EGA%Y-REQUIRE.COMPLEXPERMMBT�BRACING.hDH ALWAYS 0011SULT A PRCFESS10HAL EtIGIFIEER STEPS TO SETTINGTRUSSES RESTRAINT&BRACING FOR 3X 2 AND 4xZ PARALLEL CHORD TRUSSES RESMCC16N Y ARRIOSTRE PARA TRUSSES DE CUERDAS PARALELA.S 3X2 Y 4X2 US MEDII)AS DE LA iNsTALAa6N DE LOS TRUSSES Refer to BCSI-B7 Diagona Baring I;Install ground bracing.2)Set first truss and atizach securely to ground bracing.3)Set next 4 4&Surninary Sheet 1WOT15- Repeat Diagonal Fracing trusses vAh short rnvrmber temYloorary lateral restraint(see bellow)�4)Install top dvxvl diagonal "Tiry 15 truss spaces IM baicing'see below).5)Instalil web member plane chaconal bFac ng to Stabilize tlie first hve trusses (see W-ow).e,Install bottorit chord temporary katf-val restraint and diagonal bracing(see belor-). four trusses until all brus-ces are set. Chord Trusses"' 1)Repeat process on groups of -;z for more information.. 1)1ristale los arriostres cle tierra.2)lw�le el lunrueni truss y die segUramente at affiloSitt de berra.3)inst2le 105 proiximos 4 trusses con resticci6n Lateral temporal dea mienibro coft(vea Vea el resumen P( alpajo).4)Instate el arflostre diagonal de la cuerda superior Neat abajo).5)Instate ardostre B7-Restriccitinlf Apply D Brace to diagonal Para los planos de Ins miembro,securidarias paira,estabilice los pnmerr%CinCID trUSSM Arricistre Temporal viii"Ical webs at end Of (vea abajo).6)aistale ia resincri6n lateral temporal y andostre diagonal para,ta cuerda interior Y Permaneinte pan canidem and at bearing All Lateral R raiits Cvea abalo).7j%Repita este procedinvento en grupors-de cuatro trusses hasta que t000s tiosi trusses ruerdas locations. lapped at least two trusses eston"'Stalados. Parralelm-Para *1cp chord Temporary Lateral Restraint spacini;shall be Refer to BQSl-B2 SurrinnaLy Sheet-Truss installation&Tenuporary RestrilintirBrac no-for infore mas inlotm.3cj6n. 10 O,C�M2X.tor W chords and 15'o.c.for W chord%. information. Vea el resfimen BCSI-B2-Instalaciik,cle Trusses v RestriccibFiVALrioshre Temparal-para fri INS"rALLING — INSTALACI6N oillit-plien.�1 informaci6n. 2 Tolenaices for 0us­cf­N,,.-.,., Cut of PkWalb I -.-- --- I RESTRAINT I BRACING FOR ALL PLANES OF TRUSSES Toletanclas para fuera-,je-;'lano. Length RESTRICCION/ARRIOSTRE PARA TOWS PLANOS DE TRUSSES Lerg1h Me,S.. D150 0(ft) 3W 12 5* 63 This resiaint&bracirg fi~is for all trusses eircept 3)L2 and 4x2 paja116 c'.WM tnumses _/_­ '!4 1 7/9' 14 6' Este nnetocio de testricci6n y arriovae es pare Wo trusses extelotc,trusses de,cuefdas paralelas Max.Dow 112 7 1. 16.7' .3K2 V 4X2, Max a.. - 1)TOP CHORD-CVERDA SUPERIOR 314- 3 1-118" ieff Truss Span Top Chord Temporary Lateral Restraint(TCTLR)Spadng i" 4 1-114, 20.8' LongiftailldeTrarno, Espalciami�ento del Arriiiisiple Temporal do I&Cuerda Superior Pt-b 1-1,4- 5' 1 3fir 22.91 Up to 30' 10'OX-fflaX Hasta 30 pies 10 pies maxim Toieanres for I-V2- 6- 30'to IS' Wo.c.niax. 21 Oilt-of-plumb, 30 a 45 pies 8 pies rinAwnci Weraincas para D/fa 45'to 60' Vo.c.inall. Fuern-cle-Piornada. 6 pies rinamm 45 a 60 pies 60,to 801. CONSTRUCTION LOADING-CARGA CHE CONSTRUCC16N 4'o.c.max. 60 a K pies 4 pies ff'Alarno Do not prc�eed with conslYucluD until all lateral restraint anil bracing is securely and properlyn,place, -Consult a Professponal Engineer for lo-Lisses longer than 60. *Consulte a un IrKjeroiero Prollesional para trtisses mSs de 60 clies.. No procecia con la construiccii6n harstat clue toclas Las restric- clones lateralles y los arrPoslures esten colocadus en forma Gyi­-Board Ir See bC5L5,­for TCTLR options. apropiada y Segura. Ivea el SCsl-92-11 pard las qK'Cl�e.de TCTLR. Do not eo"ed maximum stack he�s.Refer to BMI-64 Surn P4--d-0S13 16" Refer to BCSI-B3 Surn- G n Lcialdi,,cl-4 fpr more irfformation, Aphff Sir-glea 2 bunlike RestcaWRtadw of Chords No exceda las alturas rin4eximas de rriont6n.Vea 0 resumen MY ers-for Gable BCSI-64 Catua die Contrucci6rill-para nris nforrnaci6n. res"intittacinw CA.V Ta� reintorcerrient inforniation. i Para informacion solpre ;S� restricco6niarnostre/refuem Repeart diagonal braces flow each para Arrinazories Hashales Do not overload small a ups or single trusses set of 4 tmsses. _ro vea el resufflen acsLa Q No solprecargue pequpeNos girupos;o trusses tridivdiiales. -Restricclon/Arrictstre Ground braong not snown for cianty. Repita lors; Perrinanertte be("Winlaq v amsotres diagonates Never stack materials near a peak. Minmlo,m Sty,godarins.- Para cada gi,upo de 0 Nunca amrrylone los materlailes(wm de Lin pico. 2)WEB MEMBER PLANE-PLANO DE LOS MIEMBROS SECUNDAPJOS 4 trusses. Place loads over as nwy trusses as posi�ible. Coloque las c;argas sobre tantips binses cornD Sea posi Diagonal Posittion kiaids;over bad bearing walls- A LATERAL RESTRAINT Web Members Bracing Ccloque las cargas solore lars pamlcies soportantes. I-,W-ng not &DIAGONAL BRACING AMRAMM—PIM"CIOWS L ARE VERY IMPORTANT `;I iLA RESTRIC06N Refer to BL -9�,Summary S -Truss D&BaW Jobstle Modrhcations&Installation F-ffors."' Vea el resumen BM Be Daiias rk,Trusses,Modific,icones en L,Oloqrit v Erroies.de Iftstala LATERAL Y EL Do not cut,after,or drill any structurat member of a truss unless specificafty pennitted by the ARRIOSTRE Truss Design Drawing. DIAGONAL No code,altere o perfore nitg6n n4embro estructural de on truss, bottol'Ch�ds a menos que este espedficarnente perrinitido en el Dibu)o del AK�r SON MUY Dsehlo M Truz. IMPORTANTES! Brrlcris 4&Trusses that have been overloaded during cons;4Wm or altered without the Truss Manufacturer's ev"10 truss poor approval may render the Truss Manufactures lunited warranty null and vold 10'-15'-Sarnre spacing as spaces(20'max.) i�s boktam chord Lzrt�l Restraint Trusses Que se han solprecargadio durante[a constrtwxj6n o than sido afteraidois sin la autDrizab6n Some chord and web rne-mbers not pre"a del Fatincante de Trusses,pueden lwer nulo y sin efecto la garantia firnitacla del Fabricarte Oxywn for clanty. die Trusses. 3)BOTTOM CHORD-CUERDA INFER10R. -Ceeilad the Comparierit 14-factwer far�infor-tan or a...aft.Pir.41-W Engineer for­Uranaii. To view a nar-praning PDF of this doxrurrien�Vsk iA*rw_sbCindUSftyXoanjhl. Lateral Restraints-2x4xl2 or NOTE:Trle Tr-MWx0&­x arta IMAS DOWW nIV W the P­��th,k VW,C�arid-,,a aparI14-(K 4V�) greater lapped over two trusses. M-eip�lid� --d.Proem ft lit-Ad"e6K ala�f..A-o"t P"Th,`-11"M aw Oueraj d�-~wd W er­i,trat"owrall ..rr� wol pLA bva­rYt.pia.SAFELY Tr� 1.N`i"M I,-WWIQ��ry ar`K1 blalJ`Q br--b-W Wor,Ire .W�expe-Of eialm Bomm P�rld ffwot�d with 1roM 000,manA4cure aw onsuairtim,bid Ylust dixt,11D"riaeore of maimmAnom�Ovea,at Ps~ chords "n a GuirlE for use,by a QLahttd kmdvv Desiq�or Corlitrwix it is not nbmidaol thig In-­mw49;i:x*be Wkrpritd a V"W�'L""9 DeRgiell siesgn sp­kmori Far nai w tnavig�aria x,am-p,,*"b)e rr� arlcl p�%�Wrty ft the waia,,W,­a,ftmi� Ad the�lrmel by t�Gx�bWtar Th,a,WTrA�TPT�;x�* ft�419M Diagonal Braces ev" 10 truss space,s(20'rnaiiL.) TRUSS PLATE INSTITUTE 6300 E-p- ��d_,,W]S171L 218 N.Lee St,St�_322.Almoillia,VA 22114 Some chord and web mernoers 608/27-RA9 703/683-1010--w."St.org "lax. "shown for clarity. HOJA RESUMEN DE LA GUIA DE BUENA PRACTICA PARA EL MANEJO INSTALACION RESTICCION Y ARRIOSTRE-DE US TRUSSES VANDS MAS DE 60'PIES PUP-DEN REQUERIRARRIOSTRE PERMANENTE COMPLEk,POR FAVOR,SINPREE CIONSULTE A UN INGENIERO PFCFH&ONAL �v=�nnn�Anv nr�evna kt��,,nn Art�kir ��� PORARY RESTRAINTiBRACING STEPS TO SETTING TRUSSES PASOS PARA EL MONTAJE DE TRUSSES Establish Ground Bracing Procedure: Exterior or Interior Establezca el Procedimiento de Arriostre de Tierra:Exterior o Interior i 11 V.s nX gbk H'4 ms of tfaced =0="3-AQch fio..W of oos�. 2x_twacing V end jacks in a hip—t 4-plkcalm) brace f,efscal 79. by OIJ i W-4['all P no _rnt,e'ls giole;ft oss G,onnd -to, d.9o.' Fl.ply Vace aK an ade ate dago"s and tk- f"'o'd QU I tiqual anclonaffe,—Pnnkol. _,,_I " suoll —bes amul mont" 6"kop g""M 11.1 ft.,svlm "apxny n i"d q'.1q0 11: nall. _oVV, t-,1'o."9",-J Na', �m 11401 ___ �1' r EXTERIOR GROUND BRACING TAFTERIOR GROUND BRACING MMMR QROUND SRACIWWG TO E�W WJAULL ARRIOSTRE Of 77ERPA EXTERIOR ARRIOSTRE DE TIERRA INTERIOR jAjoRJQSWJ)F7Mo1?A VITZRIOR A LA PARED LIE Determine the locations for TCTLR and Ground Braces 20 Determine las ubicaciones para TCTLR y los Arricistres de Tierra �7Zi Use truss span to determine spac- Maximum Top Chord Temporary Lateral Restraint Spacing* ing for top chord temporary lateral Truss Span TCTLR Spacing restraint(TCTLR)from table at right. Use el tramo del truss para determi- Up to 30' 10'on-center maximum nar el espaciarniento para,restricci6n —30'--45' 8'on-center maximum lateral temporal de la cuerda supe- 45'-60' 6'on-center maximum rior(TCTLR)en la tabla a la derecha. 60'-80-7--=4on-center maximum :�orniult a registered design prollessiornal for trusses longer than 60'. Fillch brook For trusses spaced greater than Z o.c.,see also 5-S 'F I undor V 0vwV(a&sTCTLR) TCTLR !F f—5-4. V-101 T-41" 4'-1' 10"or greater 3T-�Span Truss attachment required at support( E] Locate a ground brace vertical at each Locate additional TCTLR at each pitch TCTLR location. break. -7 Locate additional TCTLR over bearings if the Localice una vertical de arTios&e de Localice TCTLR adicional en cada rotura heel height is 10"or greater. tierra en cada lugar de TCTLR. de inclinalci6n. LoGalice TCTLR adicional sobre los sciportes si la altura del tal6n(heel height)es de 10 pulga- das o mis. Set First Truss and Fasten Securely to Ground Braces Coloque el Primer Truss y Fijelo Seguramente a los Arriostres de Tierra Set first truss(or gable end firame)and fasten securely to ground braces and to the wall,or as directed by the building designer Examples of first truss installed include: Coloque el primer truss(o armaz6n hastial)y ffjelo seguramente a las verticales de arriostre de tierra,y a la pared,o como se dirige el disefiador del edificio.Ejerriplos del primer truss instalado incluyen: TCrLR TCrLR locations,typ. locabons,typ TCTLR locations,typ. r— RRIOSTRE DE TIERRA EXTERIOR OUND BRACING INIT-RIOR GR"D BRACING TO END WALL A I.TE..GROUND BRACING AR1RN1T0ERT1R0FRDE`TTFRRA INTERIOR ARRIOSTRE DE TIERRA IMTERIOR A LA PARED DE EXTREMO A First truss must be attached securely to all bearings and to all required ground braces prior to removing the hoisting supports. El primer truss tiene que ser sujetado seguramente a todos soportes y a todas arriostres de tierra requendos,antes de quitar los soportes de levantaimiento. BCSI-B2 SUMMARY SHEET TRUSS INSTALLATION&TEMPORARY RESTRAINT/BRACING Install Top Chord Diagonal Bracing 50 Instale el Arriostre Diagonal de la Cuerda Superior Attach diagonal bracing to the first five trusses. Examples of diagonal bracing on first five trusses include: Coloque el arriostre diagonal a los primeros cinco trusses. Ejemplos de arriostre diagonal en los primeros cinco trusses incluyen: S�.Shu I Meke S�S�vt Membe T—K.:.y Lt..] Tenq­�Lat-1 Rftint detal R�,V­l W�fl ripwm paw 3 See-Skt Ment. ""Kbs[,�T_3 'Ternpoi�y Lateral det.9 Xtv",P.4,3 EXTERIOR GROUND BRACING HITMOR GROUND BRACING Ifavili 40ROUNE,8111141111CM T09M VAAU ARRIOSTRE DE TIERRA EXTERIOR ARRYOSTRE Of 77ERRA INTERIOR Or start applying structural sheathing. Example of structural sheathing installed on first five trusses. 0 empiece en aplicar el entablado estructural. Ejemplo de entablado estructural instalado en los primeros cinco trusses. Install Web Member Diagonal Bracing 60 Instale el Arriostre Diagonal de Miernbros Secundarios Temporary web member diagonal bracing acts with the top chord and bottom chord temporary lateral restraint and diagonal bracing to form trian- gulation perpendicular to the plane of the truss and prevents trusses from leaning or dominoing. El arriostre diagonal temporal de los miembros secundarios trabaja con la restricci6n lateral y el arriostre diagonal temporales de la cuerda superior e inferior para formar una triangulacicin perpendicular al plano del truss y evita que los trusses se inclinen o caigan como dominos. Install diagonal bracing at about 451 on web members(verticals whenever possible)located at or near rows of bottom chord lateral restraint.Web diagonal bracing must extend from the top chord to the bottom chord. Repeat at the interval shown in the Figure below. Instale el arriostre diagonal a aproximadamente 45 grados en los Diagonal miembros secundartos(verticales cuando sea posible)colocados en o bracing cerca de las filas de restricci6n lateral de la cuerda inferior Arriostre Web members diagonal para los miembros secundarios tiene que extender de la i cuerda superior a la cuerda inferior Repita a los intervalos mostrados en la Figura a la derecha. L�A - The requirements for web member permanent individual truss member restraint are specified on the truss design drawing(TDD). Refer to for more information."' Los requisitos para la restricci6n permanente de miembros individuales Bottom chords de truss para miembros secundarios son especificados en el dibujo del Diagonal braces dise5c,de truss. Vea el resumen para m6s informaci6n. every 10 truss spaces(20'tnax.) 10'-1 5'max Same spacing Note:Some chord and web members as bottom chord lateral restraint not shown for clarity. Mono trusses,deep flat trusses and other types of trusses with deep ends also require tem- porary lateral restraint and diagonal bracing on the long web members at the deep end of the truss. Los trusses de una sola pendiente, trusses planos y profundos y otros tipos de trusses con extre- mos profundos tambi6n requieren restricci6n lateral temporal y arriostre diagonal en ios miembros secundarios largos al parte profundo del truss. 4 BCSI-B2 SUMMARY SHEET BCSI-133 SUMMARY SHEET PERMANENT RESTRAINT / BRACING OF CHORDS AND WEB SPA[ISOVER 60'MAY REQUIRE XMPLEX PERIVIA1,84T BRAC111G. PLEASE ALWAYS C011SULT APROFESS1011AL E[IGII]EER ALWAYS 01.460NALLY WZACE THE CC Nil NUOUSLATEPAL RESTRAINP Gable End frames and Sloped Bottom Chords iSlEMPRE ARRIOSTRE LA 915STRICCEON LA1`17RAL CaNTYUbal OLAGONAtMENTP Armazones Hasdales,Y Cuerdas rnferiones Pendientes S.Individual Web Member Reinforcement B.Refuerro de Nifembrais Seciandaders Individualies Tne Gable End Frame should always match the profile of the adjacent trusses to permit instal- 'n,�.-,Scab,'-,U-Retnforcem.en�proprietary metal retrifbicerrient and stacked web products provide an tation of proper Bottom Chord Plane restraint&bracing unless special bracing is designed to anernative for resisting web buckling. Support the end walL L-,costra,I-,U-Refuerzro,m4mtzro de metal parentando y prriductcis de miambros securicarhas FlAmiraz6o Hastial wmpre debe encajar ei perfif de Itas trusses contiguous Para permittr la wista- amontonadicts pwvren una altemativa para resair ef torcer de Jos miem"--curidaricis, ldcicitj de re.�tncri6r?y artiostre dpropi"it-1j Ciaerda Inferux arrieticis que arrkistie esi:x�ilf es diseilaido para soportar 14 paired de aiiVernzi, P1 web �.a�—Ns Sat*E*1 hwm The foliming tabjerna�bt used jniess more spKific informaton is provided. L3 5;,�t;,,,;�re pt;ede sef UmJa a �Wonrtjo6r rr"k espeofica c,u:,--c,,c,using a flat Bottom Chord Gable End Frame,with ad)acen' that have sloped Bcmorn Chords is prosbtted till some building codes as adequate bracing of this cond-lion's WEB REINFORCEMENT FOR SINGLE PLY TRUSSES' difficult and somettrnes mpossble.Special end wall bracing design considerations ate required by the Buticling Designer if the Gat)le End Frame'D(&.Ie does not match the ad)acent TrusStS. Typ&so of W" 411111116NOW WAinim ;_--n:cL.7,�r!aso de un Arnaiji;l4agal de 14 cuerda Infew con 7russes conirtguos CujAes ft"Cififfew Wle 40 W46 Lwob of w4b M. f(well &ener Cuercas pendientes es Drobibido por a1gunos ci6digos&edifccrs pcyque ar- In" Rehiltroes" P46ftmomw riowe adecbrzr&�de esta es 61W y a veces wripowbie.Ccrns,,deraoovs e4necaL--i de ** T I scw I i ase5k,paia elamostre de 1A paredde e(fteric,sm requendos pof el Dseplad�,r delfdtliick�sf el 1 Flow hil W 2xl 2.4 - W%of-1b a perfill de Armazor Hastal ro fwce juetlo con;cs Trusses contpucis, w b6 ps bz Crew in*t* '6d&n be 2A 2d 2d uc Milt or nus(C 131,0 5'� PERMANENT BRACING FOR SPECIAL CONDITIONS b(4 - - �"ow of wit)mer"W, 00 6'�15�-I ARRIOSrRE PERMANENTE PARA CONDICIONES ESPECIALES 2 plows 2* - - 24 W ftw-tff wftc�fts werml Sway Bracing-Ardostre de-Sway- 2d ore" -Skay'brac)ng is mstat-ed at the discretion of Vit�ft,T *1qT a (4.30� the 150ding Des.,i;fner to help stabilize the vuss system a,.drimimaethe lateial movement due to wind and m-mm,c:loads. is DseAador de&,,hoo para alrudar er,estabOizar ei isistma de trusses ypiraminwwareinx*n"ientoA3terald�-b�a de viento y cargas ssmica& V Idarg Sirvav tiracing installed mritnuously across the but atsc Serves rving a to dMTbute gnivay bads between trusses of va ;5m=cNL;TFx;94*iF,-,E y A-iostrede'Sivay rates trutak7daxrtinuadamerit at travi�s del eclifoo lambein es asoolo REROZO DE KEOR-0 4,;.iiao RE,Qt"Mo para dtgribuir firs ca,gas de"vedad entre tra�de rVi*z vainando. Permanent Restraint/Bracing for the Top Chord in a Piggyback Assembly SomeThissMarturfactwersmarktht klicatiorisolithe web Lateral Restraintorteirilicicementon RestriccicirilArriostre Permanerife Para la Cuerda Superior en un Ensamblape de the tftw urs4rig tags similar to O)m above, pwyb&4* A19 unce,Fa bric a it m s 4e Tru sses mam An e r,el truss)a s utKa�-,-,ne s cio-rehwzi;�o Restricn6r, Provide res-,airr-,and bracing br�,: Ftpp-1 11,irion.1 t ateral de miemlyr,securdarios c,-,,7 etiquetas smilatr,a ias a�-,lba 1 .using rows of4x2 stress-graded lumber 9,a c4n;of 10 CLR and Diagornal Bracing,or friteivalt or less, Web Member Plarte Permanent building Stability Bracing to Transfer Wind&Seismic Forces Arriostire de EstabilAdad Permanente del Edificio del Piano de Meembros Se<undarsos Para -zcnnecting the CLR,nto the rue specified. CLR at diaphragm,or Desplazar Fuerras de Viento y Fueraras Sismicas -adding Sbuctural Sheathing or Bracing spacing S The web member restraint or reinfo,,cement specified on a TDD-.S required to rL-.St cackling Frames,or under vertical loads,Additional restraint arid biacing is By r -some other equivalent meam the typical, equzredtotransfeT lateral loads Tnw Deso due to wind andfoi seismic forces,-his restraint and braong is hrpcalff�proradecl brj the Building povet estricincirt y amovire por: C�avwv Designer. usanao Alas de 1x2 CLRrv&, n)grad Uada Por es6uerza V Arriostre vaigo"J", ta restrwoor a re&ierzo do miambms secunclarios eVec&&4j en an TDD es ro4jericic,a reststtr eltorwrbalo cagas vieftAcAeks.Pestniccx5r, x-ecrardo el CLR af defiagna dej echo,0 pasar cargas!ateri;Aes deWas a fuerzas L*werim y10 fjeaits sismicas.Esta rest.�XOC,y arrkis es ri�icamente pwato W el Disegadio,del Eattioo, .ahadjen:f��Entablado Estruclarai o Arm zanes;de Arttostre,o 52,�OQ'P,xe to foof Daphrign,' -agunos otn3saittodc-equtakoles. We,to the TDD for the maxinturn assumed spacing for attachiing the Lateral Restraint the top GOt dy-,rd of the supportrig miss. mrr"A Rebereal=pairj &qefarla Restr�xir taretaia la cuenda supersor d,4 fruss soportarite Cap 'i", Trusws The TDO provicits the assumed thickness of the restraint and mimrnum connection requirements beween the cap and the CLR rK,.Amd only Ka,�Ilip clar,l supporting truss or restraint d B=ing'Fla"*or ske."t;i,d 0-1 El TOD pr&vae ef grosor supi�de la to d-tv Stiuclumlstearlh- restrick.0n y Acts requisitos de corex4n mirtimos enlre lacapa f,e4 truss sopo--write Some Truss,Ptsigners provide oene-al o la restrtca6,. ='. rm"110, design tables and details to assist the Build- SQing Rane ing Designer in determining the Braing - \ 'V--of stfuctunit V I tnd.all ptritaw.,it Dwgonali bating required to transfer lateral bads clut to Locxit A Me*"Boll"ll�om rermanw Stea" wind and/or seis-nic forces from the Cable CLA or as spected ty Vie Wadiig Vestmv supportiry E d Framemito the roof andjor ceiling diaphragm Alilgunos 0,�eiadi:ires ce Trusses pro�,&.-n Tablas y dela!k-s de citsel5ogew.ales,Para as"relDis&`l&do.,del fdfino en datemimarelAr- nostre qvuerdo para poser cargas lateraies de&das a fue.rzas de viento y/c,fueaas si�micas W Armaziiri Hastai al do6aqrivr def techo. To view a non-printing PDF of'his dooxnent,visit www.sbdndustry.corTVb3. Para ver an PIDF de este dximento que w se puede imprimir vistira wAw sbcffd4stry.com1b3 TRUSS PLATE INSTITUTE �-e- s 14.oft. St,Se,312-AL-rcl-,VA Z 2314 631X, 114 53719 703,45V3-101',- RESTRICCION/ARRIOSTRE PERMANENTE DE LAS CUERDAS Y LOS MIEMBROS SECUNDARIOS TRAMOS MAS DE K PIES PUEDEN REQUERIR ARRIOSTRE PERMANENTE COMPLEJO.FOR FAVOR,SIEMPRE CONSULTE A UN PROFESIONAL DE DISENO REGISTRADO law, General detail for repair of broken webs, chords, and damaged or missing chord splices that meet the following conditions: •Webs must be SPF or better and 2x6 or smaller. *Chords must be SPF or better and 2x6 or smaller. • Scab must be the same size as the broken member. *Scab must be same grade or better as the broken member. • No more than two broken or cracked members per truss. *Truss must be single ply. • Perimeter of chord break area must be a minimum distance X from any heel or peak, and minimum of 6" away from any interior joint locations. • Perimeter of web break area must be a minimum distance X from web joint. C= Maximum length of damaged area (not to exceed 12"). S = Overall length of scab(shaded). Must be equal or greater than 2(X)+C. X=Minimum length of scab at each end of break area. Refer to following table for minimum length of scab,and minimum number of nails at each end of break area and maximum axial force of broken member. For all lumber, plates,web bracing,etc., refer to original drawing sealed by Robbins Engineering, Inc. *Apply all nails so as to avoid damaging of.lumber and loosening of plates at joints. Minimum end distance of 2"must be provided for all nails. 2x4 or ZX5 9CLBS "Use 1 row of 1 Od common nails spaced 3 on center into 2x3 scabs. 2x3 SCATIS *Use 2 rows of I Od common nails spaced 3"on center in each row and MINIMUM X MIN. NUMBER MAX. FOKE (Ibs) MINIMUM X MIN. NUMBER OFMA FORCE (1hes) staggered into 2x4 and 2x5 scabs. DIKANCE OF HAIIS AT AT 1.15 IZAD DISTAHM NAII.9 AT EhCH AT 1.15 I= *Use 3 rows of 1 Od common nails spaced 3"on center in each row and (in.) F-4M END OF DURATICH (in.) END OF BRW DURATION staggered into 2x6 scabs. 14 4 460 10 4 460 NOTE:Apply scab to one face of truss using nailing as specified above. 20 6 690 16 8 920 If desired,two scabs may be applied,one to each face of truss;use 6" 26 B 920 22 1 12 1390 nail spacing if scabs are applied to each face. 32 10 1150 28 16 1840 381 12 1380 34 20 2300 44 14 1G10 40 24 2760 so 16 1040 46 28 2220 is 2070 S2 32 3680 ltf\"\ 62 20 2300 58 36 1 4140 69 22 2930 64 40 1 4GUG__ 2xfi SCABS C 12" moximum jr Knirgum X MIN. NIMER MAX. FORC E 0 EACH END OF LOAD DURATICN jr DITrANCE OF NAIL5 AT (]Llos) AT 1.15 L 6 690 -N 12 1300 22 is 2070 4J$ E OF V 24 2750 1�0 16 - I% 0 '%7 213 3220 32 3690 36 32 &1 40 36 4140 44 40 4600 TOP AND BOTTOM CHORD 48 44 SC 60 \eo PITCHES VARY. 6W4 Par"EaV Blvd 52 18 am pa.F Lw",3A*�0 FL I CA,f 1.0.55!5�61 Truss manufacturer must be notified if field conditions do not match this general detail. ROBEIM LOOK�Iw pown(20 go.9oN, otoo-Asrm A&"ss oroft 4o) Rabuir" wq..Co.boo-o m-opw'stow, to, the �Ik�of t—000, Designed By: MG opo6od� both f`-7.4 1—to at occh 0�1t.Cr4w I"PkQ4&VroQ`U (�Od ""W P-4 t� t—kll' P*#*`to"a-01 oh�oth—;"by &d" (4) W L"M Otht�*dkWSG by co p�bAohoo by the T-so PW*�MRO#= WN064 D4"-S"1* 2M ROBBINS took,;n oWft� por*W with the CPO"W hCRi2WtOfty*t th- Mod.*— W--"k,Wit P*,�" �" t­opo%"—tk—d 1. .0 pook o1W/W"IL?$- —94 k--I$W -*��PW# WROC' o'"' SO" ""*"od'"--11�14 pm- o'w-tl";'n to P�t I Checked By- PO or*,�_,#,0-11 qp�oo­o 4*000ml v o aeom end, rw coo*-Ow oo too*fl to prt�A 6." a.-W9 fbrkR7- k,&-t.d othttr-�. cuttw'q-4 Nox—tso- shom bo W-�" w t.-go, 0.4" 'd ~�- Top-d �Iko-C�d. *hok be oft0,4qoP1 Engineering Inc. Aic! wadwes or"-rpt�e4 ffi�rtl*�pko� Thf."ohr va* propor"im tw=ed ;� Via ot�o of 1h"tW4 or e#d Co".f"V�NOY N 1.the oM Q@1W Sp�.*1-6—fo� Sir--C—ft W*w ot,tot owom.;� thet the destg�itoift �txrod too I&" Rev. Dote: 12/02/05 ona do Favo-in"' (AFPA). "Desir 59�0(1"U�fo� 09ht AWO P%ko &o" � o, tn"d he oo'uol 600d L—ft h1*0"d bY tho 111�WO MCI the P.O.Sox 280035, T—p., rL 33687 Co�t*d Wood T—woo"(TPI),and HUD D0091 Cri(er;tt Fo� Tru2sed ft %�1"" ;vo" by 1h# 10-1 bott;'q —ft or hil"arkol co,hotic mowft wg. No: GD-69 FURNISH A COPY OF THtS DESIGN '0 ERECTION CONTRACTOR 1. iS THE RESPONSIBILITY OF THE BUILDING DESIGNER AND TRUSS FAB. TO REVIEW THIS DRWG. & VERIFY THAT DATA INCLUDING DIM, & LOADS CONFORM TO ARCH PLAN/SPECS & rA8. TRUSS LAYOUTS. PERMANENT WEB BRACING SEE INSIDE DESIGN MANUAL FOR BCSI PERMANENT BRACING INSTALLATION INSTRUCTIONS AND FOR FURTHER INFORMATION. CONSULT THE ENGINEER OF RECORD FOR EXPLICIT INSTRUCTION REGARDING PERMANENT BRACING. CONTINUOUS LATERAL QQNTINUQU��LATEfIAL 13RACINO BRACING (lX4) lx4#3 HEM-FIR OR BETTER CONTINUOUS LATERAL BRACING TO BE EQUALLY SPACED, ATTACH WITH(2) 8d NAILS. BRACING MATERIAL TO BE SUPPLIED AND ATTACHED AT BOTH ENDS TO A SUITABLE SUPPORT BY ERECTION CONTRACTOR. ,,or-T—BRACE T--URAC THESE DETAILS APPLY TO 1.5"WIDE WOOD TRUSSES. W - USE A 2x4 T-BRACE IF THE TRUSS DESIGN SPECIFIES ONE LATERAL BRACE(MID POINT OF WEB). s USE A 2x6 T-BRACE IF THE TRUSS DESIGN SPECIFIES TWO LATERAL BRACES (AT THE THIRD POINTS OF THE WEB). 9 USE A CONTINUOUS PIECE FOR THE TBRACE, OF THE SAME GRADE AS THE WEB AND COVERING AT LEAST 90%OF THE WEB LENGTH. CENTER THE T-BRACE ON THE WEB AND f, 41 FASTEN WITH 10d COMMON NAILS SPACED 4" ON CENTER. it uj .0 Vly' E [Ak 9 WEB SCAB BRACING KA13 BRACE SCAB BRACE SAME SIZE, GRADE, AND LENGTH AS WEB MEMBER. ATTACH WITH 10d NAILS @ 4"O.C. BRACING MATERIAL TO BE SUPPLIED BY ERECTION CONTRACTOR.